HomeMy WebLinkAbout947 WORTHINGTON CIR - SPECIAL INSPECTIONS - 9/8/19939G4't Wari�n� w�1a� C� vrte.
TAL INC
SIMPSON SHEET ME
126 Hemlock P. O. Box 271 Fort Collins, CO 80522
(303) 482-2775 FAX (303) 482-0550 ' � � �"'
Metro 623-8362
S E P 0 8 1993
By LOBAR, INC.
DATE: September 8, 1993
TO: Lobar, Inc.
P. O. Box 1987
Fort Collins, CO 80522
Attn: Lloyd Jenkins
Fax: 493-7614
RE: Columbine Services Project
Model Energy Code Compliance Calcs
397 SF
Foundation wall at basement U = .68
5083 SF
Net roof with R39 insulation
636 SF
Exterior glazing U = .55
2279 SF
Exterior wall with R19 insulation
2470 SF
Floor over venter crawl space R13 insulation
Uo wall: (636�x 551 + (2279 x 051 + (397 x .68) = .234
3123
Uo roof: (5083 x 03) + (60 x .551 = .036
5143
Exterior wall Uo required = .27✓ Actual = .24
Roof Uo required = .08 ✓ Actual = .04
Floor over crawl Uo required = .08 Actual = .07
Based on these calculations this project meets the requirements of the 1986 model
energy code as it relates to the thermal envelope and mechanical systems
provisions of the code.
Tom� Wasmer, Estimator