HomeMy WebLinkAbout6213 PHEASANT CT - CORRESPONDENCE - 9/27/1993I FOUNDATION II Consulting ENGINEERING Engineers, Ltd. September 27, 1993 Commission No. 1706-05-05-05 Classic Custom Builders 605 South College Avenue Fort Collins, CO 80524 Gentlemen: ' � "s 6,213 C r We have observed the drilling of several of the ten (10) inch diameter, straight shaft piers supporting the residence under construction at Lot 6, Paragon Point P.U.D. Third Filing, a subdivision of Fort Collins, Colorado. This inspection was performed on September 27, 1993. Exposed soils measured from original grade consist of three to eight (3 - 8) feet of silty clay over a claystone bedrock which extends to the depths drilled, approximately ten to thirteen (10 - 13) feet. All piers observed were plumb, properly cleaned, and of adequate length as specified on our foundation plan, Job No. 1607-05-05-05. Water was encountered during drilling. Therefore, we recommend concrete be placed immediately after drilling of each individual caisson. Casing was not required. If you have any que,tips;-'.��pease feel free to call. Respe tfully, =C— ` Kevin W. Pattersonp';: ' FOUNDATION ENGINEERING..;',;6 NSULTING ENGINEERS, LTD. KWP/jlb 100 East 3rd Street Loveland, Colorado 80537 • (303) 663-0138