Loading...
HomeMy WebLinkAbout4900 SMALLWOOD CT - MISCELLANEOUS - 8/31/1998City of Fort Collins ENERGY SCORE Home Energy Rating Program - Version 2.0.4 ******************************************************************************* ENERGY RATING RESULT FINAL SITE Rol-rrr— Owner: KEM HOMES Address: 4900 Smallwood Zip: 80525 Phone: 223-4900 Builder: KEM HOMES Model: 2360 Devel: Timbercreek Reference #: Data File: Run Date: Year Built: Rating Firm: Site Rater: Rating Date: 240999 A:4900-SMA.DAT 08-31-1998 1998 RICHMOND ASSOCIATES DONALD RICHMOND 8-6-98 ******************************************************************************* ENERGY SCORE: *********** * G - 82 *********** G - 82 v (Least------------------------ - -------�v--- I ---- I (Most Efficient) G-0 10 20 30 40 50 60 70 80 90 100 Efficient) ******************************************************************************* This program is offered by the City of Fort Collins as an aid in comparina the energy efficiency of homes. The information provided does not constitute any warranty, express or implied, as to the presence or lack of energy features in this house, the heating fuel used in the house and its costs, or the actual energy consumption or performance of the house. City of Fort Collins ENERGY SCORE Home Energy Rating Program - Version 2.0.4 DETAILED ENERGY REPORT FOR RATED BUILDING Owner: KEM HOMES Address: 4900 Smallwood Zip: 80525 Phone: 223-4900 Builder: KEM HOMES Model: 2360 Devel: Timbercreek BUILDING CHARACTERISTICS Conditioned Space Area: 3133 sq ft Total Glazing Area: 394 sq ft Air Infiltration Rate: 0.42 AC/h Eff. Thermal Capacity: 6768 Btu/F Util. of Direct Solar: 0.63 BUILDING ENERGY SUMMARY Load Efficiency ----------------- KBtu/sf % Gas Space Heat 20.1 80.0 Gas Water Heat 6.6 54.0 Building TOTAL 26.8 COMPONENT SUMMARY: SPACE HEATING Heat Loss Coeff Btu/hr-F o Ceilings/Roofs 33.0 5 Frame Walls 125.5 20 Masonry Walls 2.5 0 Rim/Band Joists 17.3 3 Windows/Skylights 209.8 34 Sunspace - - Doors 10.5 2 Foundation Walls 30.8 5 Frame Floors 4.1 1 Slab Floors 14.7 2 Crawl Sp/Unht Bsmt 20.8 3 Infiltration 154.4 25 Envelope TOTAL 623.6 100 Active Solar Spc Ht Reference #: 240999 Data File: A:4900-SMA.DAT Run Date: 08-31-1998 Year Built: 1998 Rating Firm: RICHMOND ASSOCIATES Site Rater: DONALD RICHMOND Rating Date: 8-6-98 ENERGY SCORE *********** * G - 82 *********** Energy Consumed Fuel Cost ------------------------ KBtu/sf MMBtu $/MMBtu 25.2 78.9 4.24 12.3 38.5 4.24 37.5 117.4 Gross Heat Loss KBtu/sf 1.7 5 6.3 17 0.1 0 0.9 2 10.4 29 0.5 1 1.5 4 0.2 1 0.7 2 1.0 3 7.7 21 31.0 86 Useful Gains ------------ KBtu/sf o 0.4 3 0.6 6 0.0 0 0.0 0 6.6 61 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 7.6 70 Energy Cost $/sf 0.11 0.05 0.16 Net Heat Load ------------- KBtu/sf MMBtu 1.3 4.1 5.6 17.7 0.1 0.3 0.9 2.7 3.8 11.9 0.5 1.6 1.5 4.8 0.2 0.6 0.7 2.3 1.0 3.2 7.7 24.1 23.4 73.3 Internal Gains 0.0 0 3.3 30 -3.3 -10.3 Duct/Pipe Losses - - - - - - Furnace Losses 5.0 14 0.0 0 5.0 15.8 Space Heating TOTAL 36.1 100 10.9 100 25.2 78.9 COMPONENT SUMMARY: WATER HEATING Gas 12.3 KBtu/sf = 38.5 MMBtu Solar - - Water Hearing TOTAL 12.3 KBtu/sf = 3 8.5 MMBtu ENERGY SCORE Data Listing Date: 08-31-1998 Input Worksheet: A:4900-SMA.WS Reference Number: 240999 1. GENERAL INFORMATION Property Owner's Name Property Address Zip Code Telephone Number(s) Home Builder's Name Model Name or Number Development Name Energy Rating Company Building Plan Rating: Energy Rater's Name Energy Rating Date Site Visit Rating: Energy Rater's Name Energy Rating Date 1 KEM HOMES 2 4900 Smallwood 3 80525 4 223-4900 5 KEM HOMES 6 2360 7 Timbercreek 8 RICHMOND ASSOCIATES 9 DONALD RICHMOND 10 9-18-96 11 DONALD RICHMOND 12 8-6-98 2. BUILDING STRUCTURE Year Constructed 13 1998 Area of Conditioned Space (sq ft) 14 3133 Housing Type (1-5) 15 1 Apartment Only: Level Type (1-3) 16 0 Floors On or Above Grade (1-2) 17 2 Foundation Type(s) (1-7) 18 6 Roof Entry Line # [19) [201 [211 3. CEILINGS/ROOFS Gross Area (sq ft) 19a 1424 20a 0 21a 0 Ceiling/Roof Insulation (R-Value) 19b 40 20b 0 21b 0 Ceiling Type (1-2) 19c 1 20c 0 21c 0 4. RIM AND BAND JOISTS Area Joist Location Joist Insulation (sq ft) (1-4) (R-Value) 22a 244 22b 1 22c 16 23a 68 23b 2 23c 13 5. FRAME OR BRICK VENEER WALLS Wall Entry Gross Area Wall Location Wall Insulation Line # (sq ft) (1-4) (R-Value) [241 24a 2116 24b 1 24c 16 [251 25a 220 25b 2 25c 13 [261 26a 78 26b 3 26c 0 [271 27a 0 27b 1 27c 0 ENERGY SCORE Data Listing Input Worksheet: A:4900-SMA.WS Date: 08-31-1998 R f e erence Number: 240999 6. MASONRY WALLS ABOVE GRADE Wall Entry Gross Area Const. Type Wall Location Wall Insulat Line # (sq ft) (1-4) (1-4) (R-Value) [281 28a 75 28b 1 28c 1 28d 11 [291 29a 34 29b 1 29c 4 29d 19 [301 30a 13 30b 1 30c 3 30d 0 7. WINDOWS (INCLUDING DOOR GLAZING) Area Orientation Glazing Type Wall Entry (sq ft) (1-6) (1-21) Line #(24-30) 31a 110.3 31b 3 31c 4 31d 24 32a 31 32b 1 32c 4 32d 24 33a 35.1 33b 5 33c 4 33d 24 34a 168 34b 3 34c 4 34d 24 35a 14.7 35b 3 35c 9 35d 28 36a 29.4 36b 1 36c 9 36d 28 37a 0 37b 0 37c 0 37d 24 38a 0 38b 0 38c 0 38d 24 Area (sq ft) 39a 5.5 40a 0 41a 0 42a 0 Orientation (1-6) 39b 5 40b 0 41b 0 42b 0 8. SKYLIGHTS Pitch (?/12) 39c 7 40c 0 41c 0 42c 0 Glazing Type (1-21) 39d 4 40d 0 41d 0 42d 0 9. DOORS (OPAQUE DOOR AREAS ONLY) Area Door Insulation Storm Door (sq ft) (R-Value) (l.yes, 2.no) 43a 20 43b 4.4 43c 2 43d 44a 17.8 44b 1.7 44c 2 44d 45a 0 45b 0 45c 2 45d Roof Entry Line #(19-21 39e 19 40e 19 41e 19 42e 19 Wall Entry Line #(24-30) 24 25 0 ENERGY SCORE Data Listing Input Worksheet: A:4900-SMA.WS Date: 08-31-1998 Reference Number: 240999 10. FOUNDATION WALLS BELOW GRADE Construction Depth Type Length Below Grade Wall Location Wall Insulat (1-4) (ft) (ft) (1-2) (R-Value) 46a 1 46b 82 46c 7 46d 1 46e 11 47a 1 47b 68 47c 3 47d 2 47e 19 48a 0 48b 0 48c 0 48d 1 48e 0 11. FRAME FLOOR Floor Area Insulation Floor Location (sq ft) (R-Value) (1-3) 49a 538 49b 1.5 49c 2 50a 10 50b 20.5 50c 1 51a 75 51b 20.5 51c 3 12. SLAB FLOORS (ON OR BELOW GRADE) Exposed Floor Area Perimeter Perimeter Insulation (sq ft) (ft) (R-Value) 52a 566 52b 84 52c 0 53a 0 53b 0 53c 0 Under Slab Depth Width of Insulation Insulation Below Grade Under Slab (R-Value) (ft) (ft) 52d 0 52e 7 52f 0 53d 0 53e 0 53f 0 13. INTERIOR FINISH Drywall Thickness (0.5 to 1 in.) 54 .5 Uncarpeted Floor Slab (l.yes, 2.no) 55 2 Uncarpeted Floor Slab Area (sq ft) 56 0 Uncarpeted Floor Slab Thickness (in.) 57 4 14. ADDITIONAL MASS Mass Type Mass Area Mass Thickness (1-3) (sq ft) (in.) 58a 0 58b 0 58c 0 59a 0 59b 0 59c 0 ENERGY SCORE Data Listing Date: 08-31-1998 Volume of Cond. Space (cubic ft) 60 24860 Input Worksheet: A:4900-SMA.WS Reference Number: 240999 15. INFILTRATION Type of Infiltration Infiltration Measurement Value (1-3) (ACH or sq.in) 61 1 62 .42 16. HEATING EQUIPMENT Heating Heating Electric System Type System AFUE Furnace Input Demand Control (1-7) (%) (1000's Btu/h) (1-yes, 2.no) 63 1 64 80 65 100 66 2 17. DUCTS AND PIPES Duct or Pipe Area in Attic above Insulation (sq ft) 67 0 Attic Duct Insulation (l.yes, 2.no) 68 2 Duct or Pipe Area in Crawl Space or Unheated Basement (sq ft) 69 0 Crawl Space or Unheated Basement Duct Insulation (l.yes, 2.no) 70 2 18. DOMESTIC HOT WATER Water Heater Type (1-4) 71 Water Heater Efficiency (%) 72 1 54