HomeMy WebLinkAbout415 RED HAWK DR - MISCELLANEOUS - 8/23/2001SARA'S ENERGY SCORING DATE 1225 W Prospect P-14 OS/23/O1 FT- COLLINS CO $0526 (970)495-9922 CUSTOMER: PETS SHERMAN 415 Red Hawk Ey- FT. COLLINS CO BUILDING CONDITIONS: Interior Temp = 68 F Volume - 24675 Cu. Ft. Number of Stories 2 Wind Shield Factor 1 HOUSE TEST : Depressurized Fan Model - 3 Performed By Data Points: Exterior Temp = 85 F Above Grade Surface Area = 0 Sq. Ft. Number of occupants - 2 House Pressure 57 Fan Pressure CFM Urror Fan Configuration 52 152 134 2205 0.2 2072 0.8 Ring A 44 35 100 1792 -1.3 Ring A Ring A 28 71 52 1513 -1.2 1297 0.0 Ring A 23 40 1139 1.7 Ring A Ring A Correlation Coefficient Flow Coefficient Exponent r = .9990 C 108.60 n = 0.744 Results: Air Flow a SO Pascals : = 1996 CFM50 +/- 0.54 a 4.85 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) 86.38 Square Inches Equivalent Leakage Area (CANADA) = 176.97 Square Inches +/- 2,5$ Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 147 CFM = 73.5 CFM/OCCUPANT = 0.36 AIR CHANGES PER. HOUR O I'd SOOT - 992 (OLS) wbus @ES :O T T O c2 soli