Loading...
HomeMy WebLinkAbout4130 SPRING CANYON CT - CORRESPONDENCE - 3/9/2001Mar 09 01 11:03a WEEKS t, RSSOC_ (970)278-9450 P.1 March 9, 2001 Jena Homes Attn, Glen Wahlberg 1499 Waterwood Drive Windsor, Colorado 80550 Re: Hoffman_13_esid9nce 4130 Spring Canyon Court Fort Collins, Colorado Project No. 20335 Dear Glen - Weeks & Associates, Inc. Structural Engineers As requested we have sized the second floor support beams over the family room and study at the referenced project. It is our opinion the flush beam at the entry to the study spanning approximately 4'-6" should be (2) 2x10, supported on a 4x4 post at the south end, and 2-2x4 studs at the north end located in the wall. The flush beam over the family room at the hall spanning approximately 6'-0" should be (3) 2x10 or (2) 1-3/4"x9-1t4" LVL. This beam should be supported on a 4x4 post at the south end, and 3-2x4 studs at the north end located in the wall. The north end of the existing (4) 1-3/4"x9-1/4" LVL beam over the family room should be supported on 2-4x4 posts. Solid blocking should be provided beneath all col below or the posts should be extended through the floor to the beam, umns to the beam If we can be of further assistance please contact us. Sincerely, Weeks & Associates, Inc. ���, DMA 1 Wendy S. Thomas, E.I.T. Staff Engineer Reviewed By: GaryG. Weeks, P.E. Structural Engineer Weeks & Associates, inc. 300 Boardwalk Drive, Building 3, lint D, Fort Collins, CO 80525 Phone 970/ 225-2422; Fax 970/225-2622