HomeMy WebLinkAbout1809 N COLLEGE AVE - SPECIAL INSPECTIONS - 2/4/19921A17VAMCS27 F.2VGINEEF2Irr4a Cn 6 W) ! INC . REGISTERED PROFESSIONAL ENGINEERS AND LAND SURVEYORS P.O. Box 1391, Fort Collins CO 80522 Phone & FAX (303) 484-0533 February 4, 1992 Greg Evans 4824 E. Prospect St. Fort Collins, CO 80524 Re: Window header and support design for the Lamplighter Motel at i809 W College Ave. Ft. Collins, Larimer County, Colora o. Dear Greg, As per your request, an inspection was performed on February 4, 1992 for the Lamplighter Motel at 1809 0,College Ave. Ft. Collins, Larimer County, Colorado, to design a window header and supports to carry the roof load off the concrete block wall. The new window will be installed in the new proposed two bedroom apartment, the proposed window size is 33"x73", the window location is in the South wall, which is a bearing wall, carrying a part of the roof, the roof spans 15 feet, plus 2 feet over -hang and another 2 feet span in the hall -way. The header size should be at least 3-2x6 or 5-2x4, the support on both sides of the header should be at least 3-2x4 on each side of the header. All wood material should be Him -Fur No. 1 or better. The roof need to be supported during construction, the bottom 3 concrete blocks holes should be filled with concrete, to provide a smooth solid base for the roof supports and for the window frame. Should you have any other questions or need any more information, please feel free to call our office at (303) 484-0533. Sincerely, ari,. ohamed S. WoraXeth olorado Reg. P.E. # 23019