Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E-ELEVATION CERTIFICATE - 1721 CHOICE CENTER DRIVE - SPRING CREEK (8)
0MB No . 1660-0008 U.S. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency Expiration Date: November 30 , 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official , (2) insurance agent/company, and (3) bu il ding owner. SECTION A -PROPERTY INFORMATION FOR INSURANCE COMPANY USE A 1. Building Owner's Name Policy Number: ACC OP (FORT COLLINS) LLC A2 . Bu il d ing Street Address (including Apt., Unit, Su ite , and/or Bldg. No.) or P.O . Route and Company NAIC Number: Box No . 1721 Choice Center Drive C ity State ZIP Code Fort Collins Colorado 80524 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description , etc.) LOT 2 , CHOICE CENTER , PARCEL NUMBER 9723115001 A4. Building Use (e .g ., Residential , Non-Residential , Addition , Accessory , etc.) Accessory A5 . Latitude/Longitude : Lat. 40°33'48.37"N Long . 105°04'42 .03 "W Horizontal Datum : 0 NAO 1927 (g] NAO 1983 A6 . Attach at least 2 photographs of the bu il ding if the Certifi cate is being used to obtain flood insurance. A7 . Building Diagram Number 1A A8 . For a build ing with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 0 .00 sq ft b) Number of permanent flood open ings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade NIA c) Total net area of flood open ings in A8 .b N/A sq in d) Engineered flood openings? 0 Yes D No A9. For a building with an attached garage: a) Square footage of attached garage 11 25 .0 0 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 6 c) Total net area of flood openings in A9 .b 1200.00 sq in d) Engineered flood open ings? [g] Yes D No SECTION 8-FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 81 . NFIP Community Name & Commun ity Number 82 . County Name 83. State C ity of Fort Collins 080102 Larimer Colorado 84. Map/Panel BS .Suffix B6 . FIRM Index B7 . FIRM Panel B8 . Flood 89. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO , use Base Flood Depth) Revised Date 08069C0979 H 02-06-2013 05-02-2012 AE 4986.89 8 10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 89: [g] FIS Profile O FIRM D Community Determined D Other/Source: 811 . Indicate elevation datum used for BFE in Item 89 : D NGVD 1929 [8] NA VD 1988 D Other/Source: 812 . Is the building located in a Coastal Barrier Resources System (C BRS) area or Otherwise Protected Area (OPA)? D Yes (g] No Designation Date : D CBRS DOPA FEMA Form 086-0-33 (7/15) Replaces all previous editions . Form Page 1 of 6 ELEVATION CERTIFICATE IMPORTANT: In these spaces, copy the corresponding information from Section A . Bu ild ing Street Address (i ncluding Apt., Unit, Suite , and /or Bldg . No .) or P .O. Route and Box No . 1721 Choice Center Drive City Fort Coll ins State Colorado ZIP Code 80524 0MB No. 1660-0008 Expiration Date : November 30 , 2018 FOR INSURANCE COMPANY USE Policy Number : Company NAIC Number SECTION C-BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C 1. Bu ild ing elevations are based on : D Construction Drawings* D Bu ilding Under Construction * 0 F in ished Construction *A new Elevation Certificate will be required when construction of the building is complete . C2 . E levations -Zones A1-A30 , AE , AH , A (with BFE), VE , V1-V30 , V (with BFE), AR , AR/A , AR/AE , AR/A1-A30 , AR/AH , AR/AO . Complete Items C2 .a-h below acco rd ing to the bu il d ing d iagram specified in Item A7 . In Puerto Rico only , enter meters . Benchmark Utilized : WOODWARD Vertical Datum : NAVO 1988 ------------ 1 n d i cat e e levation datum used for the elevations in items a) through h ) below. D NGVD 1929 0 NAVO 1988 D Other/Source : ------------------------ Datum used for bu ild ing e levations must be the same as that used for the BFE. a) Top of bottom floor (i ncluding basement, crawlspace , o r enclosure floor) b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery o r equipment servicing the building (Describe type of equipment and location in Comments) f) Lowest adjacent (finished ) grade next to building (LAG ) g) Highest adjacent (finished ) grade next to building (HAG ) h) Lowest adjacent grade at lowest elevation of deck or stairs , including structura l support Check the measurement used . 4985.7 0 feet D meters N/A D feet D meters N/A D feet D meters N/A D feet D meters N/A D feet D meters 4985.2 N feet D meters 4985.7 D feet D meters N/A D feet D meters SECTION D-SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, enginee r , or architect authorized by law to certify elevation information . I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 1 B U.S. Code, Section 1001 . Were latitude and longitude in Section A provided by a licensed land surveyor? 0 Yes D No 0 Check here if attachments . Certifier's Name License Number Chad Washburn CO PLS 37963 ,,,,11il\\\\llll//J11111. ~~'~ ~ \J O L I c J:_;111//. Title ,.j:' ~".· · •• ' • .• <4' %, Professional Land Surveyor $ '0"'. · ;..,_ ~-WAs,y;,. ~% ~ '--' • "(-"V <re:;.. • c? "';::; Company Name ~ • .:Z:. '.P • ::: ~ :u z : ~ Washburn Land Surveying , LLC ~ ;g :. 3 7 9 6 3 ; g; § 1-..,..A...,.dd...,..r_e_s_s _______________________________ --t '::-o · : ;,..__ § 4025 Automation Way , Suite C4 %<' ;. . . ·~J::::f ~ u () • . • • ''"' ~ 0v/o ······· s'-)~ City State ZIP Code ;,0 11111 '.t!IA L L ~ ~\) ,,,,,,~ Fort Collins Co lorado 80528 1111111111111111111,,,, Signature Chad Washburn Digitally ligned by Chad 'Nuhl>urn Cate· 2019.12 20 15 ·24 11 -OTOa Date 12-20-2019 Telephone (970) 685-8836 Ext. Copy all pages of th is Elevation Certificate and all attachments for (1) commun ity official , (2) insurance agent/company , and (3 ) building owner. Comments (including type of equipment and location , per C2 (e), if appl icable) Vent Certification Attached. Benchmark: COFC Woodwa rd Elev:4992 .03 Datum :NAVD 1988 A9.a : Th is is a storage room ins ide an existing parking garage. C2 .e :No HVAC/Mechanical FEMA Form 086-0-33 (7/15) Replaces all previous editions . Form Page 2 of 6 ELEVATION CERTIFICATE 0MB No. 1660-0008 Expiration Date : November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Buildin g Street Address (including A pt., Unit, Suite , and/or Bldg . No .) or P.O . Route and Box No . Policy Number: 1721 Choice Center Drive City State ZIP Code Company NAIC Number Fort Coll in s Colorado 80524 SECTION E-BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1-E5 . If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A , B,and C . For Items E1-E4 , use natural grade , if available . Check the measurement used . In Puerto Rico only , enter meters . E1 . Provide e levati on information for the following and check the appropriate boxes to show whether the elevation is above o r below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a ) Top of bottom floor (incl uding basement, crawlspace , or enclos ure ) is Ofeet D meters D above or D below the HAG . b ) Top of bottom floor (incl uding basement, crawlspace , or enclosure ) is D feet D meters D above or D below the LAG . E2 . For Bu il d in g Diag rams 6-9 with permanent flood openings provided in Section A Items 8 and /or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2 .b in the d iagrams ) of the building is D feet D meters D above o r D be low the HAG . E3 . Attached garage (top of slab ) is D feet D meters D above or D below the HAG . E4 . Top of platform of machinery and /or equipment servicin g the building is Ofeet D meters D above or D below the HAG . E5 . Zone AO only : If no flood depth number is ava ilable , is the top of the bottom floor elevated in accordance with the commun ity's floodp lain management ordinance? D Yes D No D Unknown . The local official must certify this info rm ation in Section G . SECTION F -PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owne r's authorized representative who completes Sections A , B, and E for Zone A (without a FEMA-issued or commun ity-issued BFE ) or Zone AO must sign here . The statements in Sections A , B , and E are correct to the best of my knowledge . Property Owner or Owner's Authorized Representative's Name Address City State Z IP Code S ign ature Date Telephone Comments D Check here if attachments . FEMA Form 086-0-33 (7/15) Replaces all previous ed iti ons . Form Page 3 of 6 ELEVATION CERTIFICATE 0MB No . 1660-0008 Expiration Date : November 30 , 2018 IMPORTANT: In these spaces , copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Bu ildin g Street Address (including Apt., Un it , Suite , and/or Bldg. No .) or P.O . Route and Box No . Pol icy Number: 1721 Cho ice Center Drive City State ZIP Code Company NAIC Number Fort Collins Colorado 80524 SECTION G -COMMUNITY INFORMATION (OPTIONAL) The local official who is authorize d by law or ordinance to adm ini ster the community's floodplain management ordinance can complete Sections A , B, C (or E), and G of this Elevation Cert ificate . Complete the appl icable item(s) and sign be low . Check the measurement used in Items G8-G10. In Puerto Rico only , enter meters . G1 . 0 The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or arch itect who is authoriz ed by law to certify elevation information . (I ndicate the source and date of the elevation data in the Comments area below.) G2. D A commun ity official completed Section E for a building located in Zone A (without a FEMA-issued or commun ity-issued BFE) or Zone AO . G3 . [Xi The following information (Items G4-G10) is provided for community floodpla in management purposes . G4 . Permit Number G5 . Date Permit Issue~ G6 . Date Certifi cate of if _g ,qos-t ~$ /o-'f-;1.A)I Compliance/Occupancy Issued FP /JG, 7;J., 1 -Z. I -.2-0 It/ I ?. -').. 1-;;lo f 1 G7. Th is permit has been issued for : l{l New Construction D Substa nti al Improvement G8 . Elevation of as-built lowest floor (includ ing basement) Lf'f g:s-~ 7 ~feet D meters IJAVO l'f~( of the building : Datum G9 . BFE or (in Zone AO) depth of flooding at the building site : yqgeo .gq ~ feet D meters Datum jlA \J"1 Jq~ G10 . Community's design flood elevation : 4°1i1,gq · gfeet D meters Datum MA~D flt Local Official's Name Title IAA a r rii IA U; liMtc -llobi Vtf;t0V\ Flot'Jtl:~( "l.--t vt Ad.vvt..ir'Lt.~~,r Communitf Name Telephone •, (\~· ~Lf e-t -Fo rl-tJ)f /,\~~ I co I ··-....,.-..,._ q70 -DI./-IP 0"'5b , / .=" -,.. --- Sign4U~~ Date / -I 'K' -:1-o {).D Comments (including type of equipment and location , per C2(e), if applicable) '"(k H } { "-6.fo,&tjl-roo""1. wlftt.:n a~ ~~(eSs.or'-f ~uc:l-< .. >-re lt,~td~ ~(L,'( ~) · 1lu, f .JorfJf--~01/Vl ,c; \l~~c{ c.t~lv; ~jivt-e..~ Pf.eocl v~, ifu-~~ ~ {,vO,,{ ~ce.r~\ "{etl plf()v ! cu£. CH. D Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all prev ious editions. Form Page 4 of 6 ----------- BUILDING PHOTOGRAPHS ELEVATION CERTIFICATE See Instructions for Item A6. IMPORTANT: In these spaces , copy the corresponding information from Section A. Bu ild ing Street Address (including Apt., Un it , Suite , and/or Bldg . No .) or P.O. Route and Box No . 17 21 Choice Center Drive City Fort Collins State Colorado ZIP Code 80524 0MB No . 1660-0008 Expi ration Date : November 30 , 2018 FOR INSURANCE COMPANY USE Policy Number: Company NAIC Number If us in g the Elevation Cert ifi cate to obtain NFIP flood insurance , affix at least 2 building photographs below according to the instructions for Item A6 . Identify all photographs with date taken ; "Front View" and "Rear View"; and , if required , "Right Side View" and "Left Side View ." When applicable , photographs must show the foundat ion with representative examples of the flood openings or vents , as indicated in Section A8 . If submitting more photographs than will fit on this page , use the Continuation Page . Photo One Caption Exterior Looking South Clear Photo One Photo Two Caption Interior Looking West Clear Photo Two FEMA Form 086-0-33 (7 /15) Replaces all previous editions . Form Page 5 of 6 BUILDING PHOTOGRAPHS ELEVATION CERTIFICATE Continuat ion Page IMPORTANT: In these spaces, copy the corresponding information from Section A. Bu ild ing St reet Address (including Ap t., Unit , Sui te , and /or Bldg . No .) or P.O. Route and Bo x No . 172 1 Choice Center Drive City Fort Co lli ns State Colorado ZIP Code 80524 0MB No. 1660-0008 Expirat ion Date : November 30 , 20 18 FOR INSURANCE COMPANY USE Po li cy Number: Company NAIC Numbe r If subm itting more photographs than w ill fit on the preced ing page , affi x the add it ional photog raphs be low . Identify all photog raphs w ith : date taken ; "Fron t View" and "Rear V iew"; and , if requ ired , "Right Side V iew" and "Left Side View ." When applicab le , photographs must show the foundat ion w ith representative examp les of the flood ope nings or vents , as ind icated in Section A8 . Photo Three Photo Three Photo Three Caption Clear Photo Three Photo Four Photo Fou r Photo Four Caption 1 Clear Photo Four FEMA Form 086-0-33 (7/15 ) Replaces all previous ed itions . Form Page 6 of 6 I DIVISION: 08 00 00-0PENINGS SECTION: 08 95 43-VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 ICC ICC~ ICC~ ~,Fs;'Fs, ~ ~PMG ~L~TEO -~ • "2014 Recip i en t of Pres tigious Wes t ern States Se i sm ic Po licy Council (WSSPC} Awar d in Ex ce llence" INTERNATIONAL A Subs id iary of CO DE COUNC Ii'.' ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use . There is no warranty by ICC Evaluation Service , LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copy ri ght © 2019 ICC Eval u atio n Serv ice , LLC. A ll ri gh t s rese rved . ISOltEC 17065 Flroduct Certiflcalion Body #1000 EVALUATION ~ ICC SERVICE . IE..!:'~~""'?," Most Widely Accepted and Trusted ICC-ES Evaluation Report www.icc-es.org I (800) 423-6587 I (562) 699-0543 DIVISION: 08 00 00-0PENINGS Section: 08 95 43-Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS , INC . EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540- 511; #1540-570 ; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 EVALUATION SCOPE Compliance with the following codes: • 2018 , 2015 , 2012 , 2009 and 2006 International Building Code® (IBC) • 2018 , 2015, 2012 , 2009 and 2006 International Residential Code® (IRC) • 2018 International Energy Conservation Code ® (IECC) • 2013 Abu Dhabi International Building Code (ADIBC)t 1The ADIBC is based on the 2009 !BC . 200 9 IBC code sections referenced in this report are the same sections in the A DIBC . Properties evaluated: • Physical operation • Water flow 2.0 USES The Smart Vent® units are engineered mechanically operated flood vents (FVs) employed to equalize hydrostatic pressure on walls of enclosures subject to rising or falling flood waters . Certa in models also allow natura l ventilation . 3.0 DESCRIPTION 3.1 General: When subjected to rising water , the Smart Vent® FVs internal floats are activated , then pivot open to allow flow in either direction to equalize water level and hydrostatic pressure from one side of the foundation to the other. The FV pivoting door is normally held in the closed position by a buoyant release device . When subjected to rising water , the buoyant release device causes the un it to unlatch , allowing the door to rotate out of the way and allow flow . The water level stabilizes , equalizing the lateral forces . ESR-2074 Reissued February 2019 This report is subject to renewal February 2021. A Subsidiary of the International Code Council® Each unit is fabricated from stainless steel. Smart Vent® Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The SmartVEN r® Stacking Model #1540-511 and FloodVEN r® Stacking Model #1540-521 units each contain two vertically arranged openings per un it. 3.2 Engineered Opening: The FVs comply with the design pr inciple noted in Section 2 .7.2.2 and Section 2 .7.3 of ASCE/SEI 24-14 [Section 2.6 .2.2 of ASCE/SEI 24-05 (2012 , 2009 , 2006 IBC and !RC)] for a maximum rate of rise and fa ll of 5 .0 feet pe r hour (0.423 mm /s). In order to comply with the eng ineered opening requ irement of ASCE/SEI 24 , Smart Vent FVs must be installed in accordance with Section 4.0 . 3.3 Ventilation : The SmartVEN r® Model #1540-510 and SmartVEN r® Overhead Door Model #1540-514 both have screen covers w ith 1/4-inch-by-1/4-inch (6 .35 by 6.35 mm) openings , yielding 51 square inches (32 903 mm 2 ) of net free area to supply natural ventilation . The SmartVEN r® Stacking Model #1540-511 consists of two Model #1540-510 units in one assembly , and provides 102 square inches (65 806 mm 2 ) of net free area to supp ly natural venti lation . Other FVs recognized in th is report do not offer natural ventilat ion. 3.4 Flood Vent Sealing Kit: The Flood Vent Seal ing Kit Model #1540-526 is used w ith SmartVEN r® Model #1540-520 . It is a Homasote 440 Sound Barrier® (ESR-137 4) insert with 21 -2-inch-by-2- inch (51 mm x 51 mm) squares cut in it. See Figure 4 . 4.0 DESIGN AND INSTALLATION 4.1 SmartVENr® and FloodVEN T®: SmartVEN r® and FloodVEN r® are designed to be insta ll ed into walls or overhead doors of existing or new construction from the exterior side . Installation of the vents must be in accordance with the manufacturer's instructions , the app li cable code and this report . Installation clips allow mounting in masonry and concrete walls of any th ickness . In order to comply with the eng ineered opening design princ iple noted in Section 2 .7.2.2 and 2 .7.3 of ASCE/SEI 24-14 [Section 2.6.2 .2 of ASCE/SEI 24-05 (2012 , 2009 , 2006 IBC and IRC)], the Smart Vent® FVs must be installed as follows : • With a minimum of two openings on different sides of each enclosed area . • With a minimum of one FV for every 200 square ICC.ES Evaluatio n Rep o rts are not to be cons rrued as representing aes theric s or any o th er attributes n ot !Jp ecifically addressed , no r are th ey to be con strued as an endors em ent of th e subject of th e rep o rt or a recommendation fo r its use. Th ere is no wa rranty by ICC Evaluation 'e rvice, LL C, express or implied , a s to a ny fi nding or other matter in this rep o rt , o r a s to any p roduct covered by th e report. IIG == --::-- Copyright © 2019 ICC Evaluation Se rvi ce , LLC . All rights reserved . Page 1 of 5 ESR-2074 I Most Widely Accepted and Trusted feet (18 .6 m2) of enclosed area , except that the SmartVEN T® Stacking Model #1540-511 and FloodVEN T® Stacking Mode l #1540-521 must be installed with a minimum of one FV for every 400 squa re feet (37.2 m2 ) of enclosed area . • Below the base flood elevation . • With the bottom of the FV located a maximum of 12 inches (305.4 mm) above the higher of the final grade or floor and finished exterior grade immediately under each opening . 4.2 Flood Vent Sea ling Kit The Flood Vent Sealing Kit Model 1540-526 is used in conjunction with FloodVEN T® Model #1540-520. When installed and tested in accordance with ASTM E283 , the FV and Flood Vent Sealing Kit assembly have an air leakage rate of less than 0.2 cub ic feet per minute per lineal foot (18.56 I/min per lineal meter) at a pressure differential of 1 pound per squa re foot (50 Pa) based on 12 .58 lineal feet (3.8 lineal meters) contained by the Flood Vent Seal ing Kit. 5.0 CONDITIONS OF USE The Smart Vent® FVs described in this report comply with , or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Smart Vent® FVs must be installed in accordance with th is report, the applicab le code and the manufacturer's installation instructions. In the event of a conflict , the instructions in this report govern . Page 2 of 5 5.2 The Smart Vent® FVs must not be used in the place of "breakaway walls" in .coastal high hazard areas , but are permitted for use in conjunction with breakaway walls in other areas . 6.0 EVIDENCE SUBM ITT ED 6.1 Data in accordance with the ICC-ES Acceptance Cr iteria for Mechanically Operated Flood Vents (AC364), dated August 2015 (editorially revised October 2017). 6.2 Te st report on air infiltrat ion in accordance with ASTM E283 . 7.0 IDENTIFICATION 7.1 The Smart VEN T® models and the Flood Vent Sealing Kit recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products , Inc.), the mode l number, and the evaluation report number (ESR-2074). 7.2 The report holder's contact information is the following : SMART VENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877) 441-8368 www.smartvent.com info@smartvent.com TABLE 1-MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE (in.) COVERAGE (sq. ft.) FloodVENT"' 1540-520 15~/4" X 7~/4" 200 SmartVEN T® 1540-510 15 3/4" X 73/4" 200 FloodVEN T® Overhead Door 1540-524 15 3/4" X 73/4" 200 SmartVEN T® Overhead Door 1540-514 15 3/4 " X 73/4" 200 Wood Wall FloodVEN T® 1540-570 14" X 83/4" 200 Wood Wa ll FloodVENT® Overhead Door 1540-574 14" X 83/4" 200 SmartVENT® Stacker 1540-511 16" X 16" 400 FloodVent® Stacker 1540-521 16" X 16" 400 For SI : 1 inch= 25.4 mm ; 1 square foot= m2 FIGURE 1-SMART VENT: MODEL 1540-510 ESR-2074 I Most Widely Accepted and Trusted Page 3 of 5 FIGURE 2-SMART VENT MODEL 1540-520 FIGURE 3-SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN FIGURE 4-FLOOD VENT SEALING KIT fV~LU~T.ON ~ 'CC SERV ICE • !.=..'."~··"~-" Most Widely Accepted and Trusted ICC-ES Evaluation Report www.icc-es.org I (800) 423-6587 I (562) 699-0543 DIVISION: 08 00 OD-OPENINGS Section: 08 95 43-Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC . EVALUATION SUBJECT: ESR-207 4 CBC and CRC Supplement Reissued February 2019 This report is subject to renewal February 2021 . A Subsidiary of the International Code Council® SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520 ; #1540-521; #1540-51 O; #1540-511 ; #1540- 570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent® Automatic Foundation Flood Vents , recognized in ICC-ES master evaluation report ESR -2074 , have also been evaluated for compliance with codes noted below . Applicable code edition: • 2016 California Building Code (CBC) • 2016 California Residential Code (CRC ) 2.0 CONCLUSIONS 2.1 CBC: The Smart Vent® Automatic Foundation Flood Vents , described in Sections 2 .0 throug h 7.0 of the master evaluation report ESR-2074 , comply with 2016 CBC Chapte r 12 , provided the design and installation are in accordance with the 2015 International Building Code® (IBC) prov isions noted in the master report and the add iti onal requirements of CBC Chapters 12 , 16 and 16A , as app licable . The products recognized in this supplement have not been evaluated under CBC Chapter 7A for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone with in State Respons ibility Areas or any Wildland-Urban Interface Fire A rea . 2.2 CRC: The Smart Vent® Automatic Foundation Flood Vents , described in Sections 2 .0 through 7.0 of the master evaluation report ESR -2 074 , comp~ with the 2016 CRC , provided the design and installation are in acco rdance with the 2015 International Residential Code (I RC ) provis ions noted in the master report. The products recognized in this supplement have not been evaluated under 2016 CRC Chapter R337 , for use in the exterior des ign and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibil ity Areas or any Wildland-Urban Interface Fire Area . The products recognized in t his supplement have not been evaluated for compliance with the International Wildland-Urban Interface Code®. This supplement exp ires concurrently with the master report , reissu ed February 20 19 . IC C -ES Evaluation Reports are no t to be construed as represent111g aesth ell cs o r any oth er aur,butes not .\pecifical/y addressed. nor a re they to he construed as an endorsem ent of the subject of th e rep o rt or a r ecomme11dat 1011 fo r it s use. Th ere 1s n o warranty by I C Evaluauo n S ervice, LLC. express or implied , a .\' to any findmg or o ther mailer in th1 .\· rep o rt , o r as to any product covered by the repo rl. Copyright CCI 2019 ICC Eva luation Service , LLC . All ri ghts reserved . Page 4 of 5 ' . ~ 1,'1° fVhlU~T ,ON "R'1IU ~,~ .... ".'." Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-207 4 FBC Supplement Reissued February 2019 This report is subject to renewal February 2021 . www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00-0PENINGS Section: 08 95 43-Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-51 O; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to ind icate that Smart Vent® Automatic Foundation Flood Vents , recognized in ICC-ES master report ESR-2074 , have also been evaluated for compliance with the codes noted below . Applicable code editions: • 2017 Florida Building Code-Building • 2017 Florida Building Code-Residential 2.0 CONCLUSIONS The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7 .0 of the master evaluation report ESR-2074 , comply with the Florida Building Code-Building and the FRC , provided the design and installation are in accordance w ith the 2015 International Building Code ® provis ions noted in the master report . Use of the Smart Vent® Automatic Foundation Flood Vents has also been found to be in compliance with the High-Velocity Hurricane Zone provis ions of the Florida Building Code-Building and the Florida Building Code-Residential . For products falling under Florida Rule 9N-3 , verification that the report holder's quality assurance program is audited by a quality assurance entity app roved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved val idation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement exp ires concurrently with the master report , re issued February 2019. ICC -ES Evalua t,on Reports are no t to be cons trued a s rep resenting aesthe/J cs o r any oth er a ttr,hutes no t sp ecifically addressed , no r are th ey to he construed as a n endorsem ent of the s uh1 ect of the rep o rt or a recommendat10 n fo r its use. Th ere u no wa rra nty by ICC £l'alua 11 on Serwce. llC, express o r 1mpl,ed, Gl' to a ny findtng o r o th er molter m th ,.,. rep ort. or a s to any product co vered by the rep o rt. Copyright CC> 2019 ICC Evaluation Service , LLC . All rights reserved . Page 5 of 5