Loading...
HomeMy WebLinkAboutE-ELEVATION CERTIFICATE - 621 WEST MAGNOLIA STREET - OLD TOWN (6)0MB No . 1660-0008 U.S. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency Expiration Date: November 30 , 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community officia l, (2) insurance agent/company, and (3) building owner. SECTION A -PROPERTY INFORMATION FOR INSURANCE COMPANY USE A1 . Building Owner's Name Policy Number: James & Jennifer Pfiester A2. Building Street Address (including Apt., Un it, Suite , and/or B ldg . No .) or P .0 . Route and Company NAIC Number: Box No . 621 West Magnolia Street City State ZIP Code Fort Colfins Colorado 80524 A3 . Property Description (Lot and Block Numbers , Tax Parcel Number, Legal Description , etc.) Lot 1, Magnolia West Subd ivi sion A4 . Build ing Use (e.g., Residential , Non-Residential , Add ition , Accessory , etc.) Res identi al addition & attached garage AS . Latitude/Longitude : Lat. 40°34'57 .65" Long . 1os·os·1 4 .35 " Horizontal Datum : D NAO 1927 [8J NAO 1983 A6 . Attach at least 2 photographs of the bu ilding if the Certificate is be ing used to obtain flood insurance. A7 . Build ing Diagram Number 9 AB. For a building with a crawlspace or enclosure(s): a) Square footage of crawJspace or enclosure(s) 715-.00 sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1 .0 foot above adjacent grade 4 c) Total net area offload openings in A8 .b 536 .00 sq in d) Eng ineered flood openings? !RJ Yes 0 No A9. For a building with an attached garage : a) Square footage of attached garage 396.00 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 2 c) Total net area of flood open ings in A9 .b 268.00 sq in d) Engineered flood open ings? [8J Yes 0No SECTION B-FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 81. NFIP Community Name & Commun ity Number 82. County Name 83. State FORT COLLINS 080102 LARIMER Colorado 84. Map/Panel 85. Suffix 86. FIRM Index 87. FIRM Panel 88. Flood 89. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO , use Base Flood Depth) Revised Date 08069C0979/SHT3 H 02-06-2013 5-~-l.t>I z.. / X/100 YEAR 5007 .6 7-15-Z.&0.3 810. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 89: D FIS Profile D FIRM D Community Determined [8J Other/Source: CITY OF FT. COLLINS/ OLD TOWN MASTER PLAN 811 . Indicate elevation datum used for BFE in Item 89: 0 NGVD 1929 [8J NA VD 1988 D Other/Source : 812. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (O PA)? D Yes [8J No Designation Date : D CBRS DOPA FEMA Form 086-0-33 (7/15) Replaces all previous editions . Form Page 1 of 6 ELEVATION CERTIFICATE IMPORTANT: In these spaces , copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Su ite , and/or Bldg . No .) or P .O. Route and Box No . 621 West Magnolia Street City Fort Collins State Colorado ZIP Code 80524 0MB No. 1660-0008 Expiration Date : November 30 , 2018 FOR INSURANCE COMPANY USE Policy Number: Company NAIC Number SECTION C -BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1 . Building elevations are based on: D Construction Drawings* D Build in g Under Construction• [R] F ini shed Construction *A new Elevation Certificate wiH be requ ired when construction of the building is complete . C2 . Elevations -Zones A1-A30 , AE , AH , A (with BFE), VE , V1-V30 , V (with BFE), AR , AR/A, AR/AE , AR/A1-A30 , AR/AH , AR/AO . Complete Items C2 .a-h below according to the building diagram specified in Item A7. In Puerto Rico only , enter meters. Benchmark Utilized : CSU 2 Vertical Datum : NAVO 88 ------------ 1 n di cat e elevation datum used for the elevations in items a) through h) below . D NGVD 1929 [R] NAVO 1988 D Other/Source : _____________________ _ Datum used for building elevations must be the same as that used for the BFE . a) Top of bottom floor (including basement, crawlspace , or enclosure floor) b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of mach inery or equipment servicin g the building (Describe type of equ ip ment and location in Comments) f) Lowest adjacent (finished) grade next to bu itdi ng (LAG) g) Highest adjacent (finished) grade next to building (HAG) h) Lowest adjacent grade at lowest elevation of deck or stairs , includ ing structural support Check the measurement used. 5006.3 (R] feet D meters 5009 .7 [R] feet D meters N/A [R] feet D meters 5007 .8 [R] feet D meters 5009 .0 [R] feet D meters 5007.8 [R] feet D metefs 5008 .2 (R] feet D meters N/A [R] feet D meters SECTION D-SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be pooishable by fine or imprisonment under 18 U.S. Code, Section 1001 . Were latitude and longitude in Section A provided by a licensed land surveyor? [R] Yes D No [R] Check here if attachments . Certifier's Name Steven Parks Title Owner Company Name Majestic Surveying , LLC Address 1111 Diamond Valley Drive #104 City Windsor License Number 38348 State Colorado Date I O-U.--'2-0/ ZIP Code 80550 Telephone (970) 833-5698 Ext . th is Elevati on Certificate and all attachments for (1) community official, (2) in surance agenVcompany , and (3) build in g owner. Comments (including type of equipment and location , per C2 (e), if applicable) AC Un it on West side of building (C2E) Flood Vent= Smart Vent 1540-520 rated fro 200 sq . ft . See attached certification. Benchmark (C2) CSU2 e1evation=5006.29 Sump Pump in crawlspace See attached letter confirming installation of flood resistant materials from High craft Builders FEMA Form 086-0-33 (7/15) Replaces all previous ed itions . Form Page 2 of 6 ~------------------------------------------------------------ ELEVATION CERTIFICATE 0MB No . 1660-0008 Expiration Date : November 30 , 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg . No.) or P.O . Route and Box No . Policy Number: 621 West Magnolia Street City State ZIP Code Company NAIC Number Fort Collins Colorado 80524 SECTION E-BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1-E5. If the Certificate is intended to support a LOMA or LOMR-F request , complete Sections A , B,and C. For Items E1-E4, use natural grade , if available . Check the measurement used . In Puerto Rico only , enter meters . E1 . Prov ide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor CTncluding basement , crawlspace , or enclosure) is Oteet D meters D above or D below the HAG . b) Top of bottom floor (including basement, crawlspace , or enclosure) is Oteet 0 meters 0 above or 0 below the LAG. E2 . For Building Diagrams 6-9 with permanent flood open ings prov ided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in Oteet D meters 0 above or 0 below the HAG . the diagrams) of the building is E3 . Attached garage (top of slab) is Oteet D meters D above or 0 below the HAG. E4. Top of platform of machinery and/or equipment 0feet 0 meters 0 above or 0 below the HAG . servicing the bu ilding is ES . Zone AO only : If no flood depth number is ava ilable, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? 0 Yes 0 No 0 Unknown . The local official must certify this information in Section G . SECTION F-PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A , B, and E for Zone A (without a FEMA-issued or community-issued BFE) or Zone AO must sign here. The statements in Sections A , B, and E are correct to the best of my knowledge . Property Owner or Owner's Autho ri zed Representative 's Name Address City State Z IP Code Signature Date Telephone Comments D Check here if attachments . FEMA Form 086-0-33 (7/15) Replaces all previous editions . Form Page 3 of 6 ELEVATION CERTIFICATE 0MB No . 1660-0008 Expiration Date : November 30, 2018 IMPORTANT: In these spaces, copy the correspond ing information from Section A . FOR INSURANCE COMPANY USE Building Street Address (including Apt ., Unit , Su ite, and/or Bldg. No.) or P.O . Route and Box No. Policy Number: 1621 West Magnolia Street City Sta te ZIP Code Company NAIC Number Fort Coll in s Colorado 80524 SECTION G-COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ord inance to adm inister the community's floodplain management ordinance can comp lete Sections A, B , C (or E), and G of this Elevation Cert ificate. Complete the app licable item(s) and sign below . Check the measurement used in Item s G8-G10. In Puerto Rico only, enter meters . G1. D The in format ion in Section C was taken from ot her documentation that has been signed and sealed by a licensed surveyor , engineer, or architect who is authorized by law to certify elevation information . (Indicate the source and date of the elevat ion data in the Comments area below .) G2 . D A commun ity official completed Section E for a building located in Zone A (without a FEMA-i ssued or commun ity-issued BFE) or Zone AO . G3. ~ The fo ll owing information (Items G4-G10) is provided for community floodplain management purposes . G4 . Permit Number GS . Date Permit Issued G6 . Da te Certificate of Compli ance/Occupancy Issued BP 81804263 FP 11563 BP 7-18-2018 FP 7-2-2018 10-23-2019 G7 . Th is perm it has been issued for : 1il New Construction D Substantial Improvement GB . Elevation of as-built lowest floor (in clud in g basement) 5006 .3 ~ feet D meters of the building : Datum NAVD88 G9. BFE or (in Zone AO) depth of flooding at the bu il ding site : 5007 .6 ~ feet D meters Da t um NAVD88 G10 . Commun ity's design flood elevation : 5008 .6 D feet D meters Da t um NAVD88 Local Official's Name Tit le Marsha Hil mes-Robin son Floodplain Administrator Community Name Telephone City of Fort Collins , Colorado 970-224-6036 Signature Date ~~~h6~n-10-22-2019 Comments (including type of equipment and location, per C2(e), if appl icable) Addition was co nstructed with a crawl space . The first floor level is 5009. 7. Per C2e is an air conditioning un it on a raised pad . See attached letter from the architect regarding flood resistant materials in the garage . Eng ineered flood vents are used in both the crawl space and the garage (see attached certifi cation). D Check here if att achments . FEMA Form 086-0-33 (7/15) Replaces all previous ed iti ons . Form Page 4 of 6 BUILDING PHOTOGRAPHS ELEVATION CERTIFICATE See Instructions for Item A6 . IMPORT ANT: In these spaces, copy the corresponding infonnation from Section A. Building Street Address (including Apt., Unit , Suite, and/or Bldg. No .) or P.O . Route and Box No. 621 West Magnolia Street City Fort Collins State Colorado ZIP Code 80524 0MB No. 1660-0008 Expiration Date : November 30 , 2018 FOR INSURANCE COMPANY USE Policy Number: Company NAIC Number If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 build ing photographs below according to the instructions for Item A6 . Identify all photographs with date taken ; "Front View" and "Rear View"; and, if required , "Right Side View" and "Left Side View." When applicable , photographs must show the foundat ion with representative examples of the flood openings or vents, as indicated in Section AB . If submitting more photographs than will fit on this page , use the Continuation Page. Photo One Caption AIR CONDITIONER 10-1-2019 Clear Photo One Photo Two Photo Two Caption FLOOD VENT SOUTHEAST CORNER OF ADDITION 7-24-2019 Clear Photo Two FEMA Form 086-0-33 (7/15) Replaces all previous editions . Form Page 5 of 6 -------~J BUILDING PHOTOGRAPHS ELEVATION CERTIFICATE Continuation Page IMPORTANT: In these spaces, copy the corresponding infonnation from Section A. Bu ild ing Street Address (includ ing Apt., Un it , Suite , and/o r. Bldg . No.) or P.O. Route and Box No. 621 West Magnoli a Street City Fort Collins State Colorado ZIP Code 80524 0MB No. 1660-0008 Expi ration Date : November 30, 2018 FOR INSURANCE COMPANY USE Policy Number: Company NAIC Number If submitting more photographs than will fit on the preced ing page , affix the additional photographs below. Identify all photographs with : date taken ; "Front View" and "Rear View"; and , if required , "Right Side View" and "left Side View." When appl icable , photographs must show the foundation with representative examples of the flood openings or vents , as ind icated in Section AB. Photo Three Photo Three Caption FLOOD VENT EAST SIDE OF GARAGE 9-24-2019 Clear Photo Three Photo Four Caption INSIDE OF GARAGE 9-24-2019 Clear Photo Four FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 6 DIVISION : 08 00 00-0PENINGS SECTION: 08 95 43-VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 ICC§) ICl:;s) ~ ~ ~ PMG LISTED a I • 112014 Recipient of Presti gious Western States Se ism ic Policy Council {WSSPC} Awar d in Ex cellence " b . d . f INTERNATIONAL ASu SI 1aryo COOECOUNC lr ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of th e subject of the report or a re co mmendation for its use . There is no warranty by ICC Evaluation Service , LLC, express or imp lied, as to any finding or other matter in this report, or as to any product covered by th e report. Cop y r ig ht © 2019 ICC Eva l ua tio n Service , LLC. A ll r ig hts rese rved . ISOllEC 17085 Product Certiflcatlof'l Body #1000 f'IALLe 1 ,ON [i ',I' SERVICE . !..=...'""'.'"·''~" Most Widely Accepted and Trusted ICC-ES Eva lu at io n Report www.icc-es.org I (800) 423-6587 I (562) 699-0543 DIVISION: 08 00 00-0PENINGS Section: 08 95 43-Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC . EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540- 511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 EVALUATION SCOPE Compliance with the following codes: • 2018 , 2015 , 2012 , 2009 and 2006 International Building Code® (IBC) • 2018, 2015 , 2012 , 2009 and 2006 International Residential Code® (IRC ) • 2018 International Energy Conservation Code® (IECC) • 2013 Abu Dhabi International Building Code (ADIBC}t t The AD IBC is based on the 2009 !B C. 200 9 !B C cod e sections referenced in this report are the same section s in th e A D IB C. Properties evaluated: • Physical operation • Water flow 2 .0 USES The Smart Vent® units are eng ineered mechanically operated flood vents (FVs) employed to equalize hydrostatic pressure on walls of enclosures subject to rising or falling flood waters . Certain models also allow natural vent ilation . 3.0 DESCRIPTION 3.1 General: When subjected to rising water , the Smart Vent® FVs internal floats are activated , then pivot open to allow flow in either direction to equal ize water level and hydrostatic pressure from one side of the foundat ion to the other. The FV pivoting door is normally held in the closed position by a buoyant release device . When subjected to rising water, the buoyant release device causes the unit to unlatch , allowing the door to rotate out of the way and allow flow . The water level stabilizes , equalizing the lateral forces . ESR-2074 Reissued February 2019 This report is subject to renewal February 2021 . A Subsidiary of the International Code Council® Each unit is fabricated from stainless stee l. Smart Vent® Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The SmartVEN T® Stacking Model #1540-511 and FloodVEN T® Stacking Model #1540-521 un its each contain two vertically arranged openings per un it. 3 .2 Engineered Opening: The FVs comply with the design pr inciple noted in Section 2 .7.2.2 and Section 2 .7 .3 of ASCE/SEI 24-14 [Section 2.6 .2.2 of ASCE/SEI 24-05 (2012 , 2009 , 2006 IBC and IRC)J for a maximum rate of rise and fall of 5 .0 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24 , Smart Vent FVs must be installed in accordance with Section 4.0 . 3.3 Ventilation: The SmartVEN T® Model #1540-510 and SmartVEN T® Overhead Door Model #1540-514 both have screen covers with 1/4-inch-by-1/4-inch (6 .35 by 6 .35 mm) open ings , yielding 51 square inches (32 903 mm 2 ) of net free area to supply natural ventilation . The SmartVEN T® Stacking Model #1540-511 consists of two Model #1540-510 un its in one assembly, and provides 102 square inches (65 806 mm 2 ) of net free area to supply natural ventilation . Other FVs recognized in th is report do not offer natural ventilation . 3.4 Flood Vent Sealing Kit: The Flood Vent Sealing Kit Model #1540-526 is used with SmartVEN T® Model #1540-520 . It is a Homasote 440 Sound Barrier® (ESR-1374) insert with 21 -2-inch-by-2- inch (51 mm x 51 mm ) squares cut in it. See Figure 4 . 4.0 DESIGN AND INSTALLATION 4.1 SmartVENT® and FloodVENT®: SmartVEN T® and FloodVEN T® are designed to be installed into walls or overhead doors of exi sting or new construction from the exterior side . Installation of the vents must be in accordance with the manufacturer's instructions , the applicable code and this report . Installation clips allow mounting in masonry and concrete walls of any th ickness. In order to comply with the engineered opening design principle noted in Section 2 .7 .2.2 and 2.7 .3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012 , 2009 , 2006 IBC and IRC}J , the Smart Vent® FVs must be installed as follows : • With a minimum of two openings on different sides of each enclosed area . • With a minimum of one FV for every 200 square ICC-ES Evaluation Reports are not to be co nstrued as representing aesthetics o r any o th er allrihutes not .,pecifically addressed, no r are th ey to be construed as an endorsement of the subject of th e report or a recommendatio n fo r it.,· use . There is no warran ty by f, £,,aluation Service, LLC, express or imp/;ed, as to any finding or o th er mailer in thi s report , o r as to any product covered by th e report. Cop yright © 2019 ICC Eval uation Service, LLC. All righ ts reserved . Page 1 of 5 ESR-2074 I Most Widely Accepted and Trusted feet (18.6 m2 ) of enclosed area , except that the SmartVEN T® Stacking Model #1540-511 and FloodVEN T® Stacking Model #1540-521 must be installed with a minimum of one FV for every 400 square feet (37.2 m2) of enclosed area . • Below the base flood elevation . • With the bottom of the FV located a maximum of 12 inches (305.4 mm) above the higher of the final grade or floor and finished exterior grade immediately under each open ing . 4.2 Flood Vent Sealing Kit The Flood Vent Sealing Kit Model 1540-526 is used in conjunction with FloodVEN T® Model #1540-520 . When installed and tested in accordance with ASTM E283 , the FV and Flood Vent Sealing Kit assembly have an air leakage rate of less than 0.2 cubic feet per minute per lineal foot (18 .56 I/min per lineal meter) at a pressure differential of 1 pound per square foot (50 Pa) based on 12 .58 lineal feet (3 .8 lineal meters) contained by the Flood Vent Sealing Kit. 5.0 CONDITIONS OF USE The Smart Vent® FVs described in this report comply with , or are suitable alternatives to what is specified in , those codes listed in Section 1.0 of this report , subject to the following conditions : 5.1 The Smart Vent® FVs must be installed in accordance with this report , the applicable code and the manufacturer's installation instructions . In the event of a conflict , the instructions in this report govern . Page 2 of 5 5.2 The Smart Vent® FVs must not be used in the place of "breakaway walls " in coastal high hazard areas , but are permitted for use in conjunction with breakaway walls in other areas. · 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance w ith the ICC-ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015 (editorially revised October 2017). 6.2 Test report on air infiltration in accordance with ASTM E283 . 7.0 IDENTIFICATION 7 .1 The Smart VEN T® models and the Flood Vent Sealing Kit recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products , Inc.), the model number, and the evaluation report number (ESR-2074). 7.2 The report holder's contact information is the follow ing : SMART VENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877) 441-8368 www.smartvent.com info@smartvent.com TABLE 1-MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE (in.) COVERAGE (sq. ft.) FloodVEN 1540-520 15/4"X7/4" 200 SmartVEN T® 1540-510 15 3/4" X 73/4" 200 FloodVENT® Overhead Door 1540-524 15 3/4°' X 73/4°' 200 SmartVEN T® Overhead Door 1540-514 15 3/4" X 73/4" 200 Wood Wall FloodVEN T® 1540-570 14" X 83/4" 200 Wood Wall FloodVEN T® Overhead Door 1540-574 14" X 83/4°' 200 SmartVEN T® Stacke r 1540-511 16" X 16" 400 FloodVent Stacker 1540-521 16" X 16 " 400 For SI: 1 inch = 25.4 mm ; 1 square foot= m2 FIGURE 1-SMART VENT: MODEL 1540-510 ' > ESR-2074 I Most Widely Accepted and Trusted Page 3 of 5 FIGURE 2-SMART VENT MODEL 1540-520 FIGURE 3-SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN FIGURE 4-FLOOD VENT SEALING KIT EvALUA i 10'1 ~ ICC SERVICE M w ·d I A d d T d 1000,0 ,,0 0 OSt I e y CCepte an ruste [_l;__ •••• IC C-ES Evaluation Report www.icc-es .org I (800) 423-6587 I (562) 699-0543 DIVIS ION : 08 00 00-0PENINGS Section: 08 95 43-Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: ESR-207 4 CBC and CRC Suppl e m e nt Reissued February 2019 This report is subject to renewal February 2021 . A Subsidiary of the International Code Council ® SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520 ; #1540-521; #1540-51 O; #1540-511 ; #1540- 570; #1540-574; #1540-524 ; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to ind icate that Smart Vent® Automatic Foundation Flood Vents , recogni zed in ICC -ES maste r eva luation report ESR-2074 , have also been eva luated for comp liance w ith codes noted be low . Applicable code edition: • 2016 Californ ia B uildin g Code (CBC ) • 2016 Californ ia Resid en tial Code (CRC ) 2.0 CONCLUSIONS 2.1 CBC : The Smart Vent® Automatic Foundation Flood Vents , described in Sections 2 .0 through 7 .0 of the master eva luation report ESR -20 74 , comp ly with 2016 CBC Chapter 12 , provided the design and installation are in accordance w ith the 2015 International Building Code ® (IBC ) provisions no ted in the master report and the additional requirements of CBC Chapters 12 , 16 and 16A , as applicable . The products recognized in th is supp lement have not been evaluated under CBC Chapte r 7 A for use in the exterior design and construction of new bu ild ings located in any Fire Hazard Seve ri ty Zone w ithin State Respons ibilit y Areas or any W ildland-Urban Interface Fire Area . 2.2 CRC: The Smart Vent® Automatic Foundation Flood Vents , described in Sections 2.0 through 7.0 of the master evaluation report ESR -207 4 , comp,!y with the 2016 CRC , provided the des ign and installation are in accordance with the 2015 International Resid entia l Code (IRC) provisions noted in the master report . The products recognized in th is supp lement have not been eva luated under 2016 CRC Chapter R337 , for use in the exterior des ign and construction of new bu ildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland -Urban Interface Fire Area. The products recogn ized in this supplement have not been evaluated for compl iance with the Internationa l Wi ld land-Urban Interface Code ®. Th is supplement expires co ncurrently with the master report , re issued February 20 19 . !CC·ES Evaluation Reports are not to be construed as representing ae.,·thetics or any other a lt rtbutes no t specifically addressed, nor are th ey to be construed as an endorsem ent of the subjecl of the report or a recommendation for it.,· use. There is no warranty by ICC Evaluation Sen1ice, LlC, express or implied, as to any finding or o ther ma/fer in 1his report, or as 10 any product covered by the report. Copy right © 2019 IC C Eva lua ti on Service , LLC . All ri ghts re serve d. -· ==-~- Page 4 of 5 f VALUATIO N IE ICC SER VI CE • ,_ '""••••••" Most Widely Accepted and Trusted ~-., ~ ICC-ES Evaluation Report ESR-207 4 FBC Supplement Reissued February 2019 This report is subject to renewal February 2021 . www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00-0PENINGS Section: 08 95 43-Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-51 O; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent® Automatic Foundation Flood Vents , recognized in ICC-ES master report ESR-2074 , have also been evaluated for compliance with the codes noted below . Applicable code editions: • 2017 Florida Building Code-Building • 2017 Florida Building Code-Residential 2.0 CONCLUSIONS The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2 .0 through 7.0 of the master evaluation report ESR -2074 , comply w ith the Florida Building Code-Building and the FRC , provided the design and installation are in accordance with the 2015 International Building Code ® provisions noted in the master report . Use of the Smart Vent® Automatic Foundation Flood Vents has also been found to be in compliance with the High-Velocity Hurricane Zone prov isi ons of the Florida Building Code-Building and the Florida Building Code-Residential . For products falling under Florida Rule 9N-3 , verification that the report holder's quality assurance program is audited by a qual ity assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsib ility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report , re issued February 2019. JCC-ES Ev a/ua oon Reports are nor to be cons trued as rep resentin g aes th etics or any other auribwes nor specifically addressed. nor are th ey to be constru ed a~· an endorsement of th e subject of th e report o r a recommendation fo r its use. There is no warranty by ICC E valuation Servfr.:e, LLC, express or implied, as to any finding or o th er maller in this report, o r as to any producl covered by the report. Copyright © 2019 ICC Evaluation Service , LLC . All rights reserved . Page 5 of 5 . . Attn: 429 S. HOWES STREET, FORT COLLINS, CO 80521 970.472.8100 • WWW.HIGHCRAFT.NET Marsha Hilmes-Robinson , CFM Floodplain Administrator City of Fort Collins Utilities Re: 621 W . Magnolia Elevation Certifi cate I have v isited the comp leted garage at 621 West Magnolia and observed that flood resistant materials have been used up to the Regulatory Flood Protection Elevation . Lowest adjacent grade, at the top of the driveway, has been placed at 5007.8'; and the RFPE at this property is 5008 .6'. I've included photos below documenting the presence of a concrete stem wall in the garage that extends above the RFPE . Jeff Gaines HighCraft Builders DESIGN. BUILD. REMODEL. Marsha Hilmes-Robinson From: Sent: To: Cc: Subject: Attachments: Follow Up Flag: Flag Status: Hi Marsha and Steve, Jeff Gaines <Jeff@highcraft.net > Wednesday, October 16, 2019 1 :34 PM Marsha Hilmes-Robinson stevenp@majesticsurveying.com Re : 621 West magnolia 621 Magnolia -Flood Resistant Materials.pdf Follow up Flagged I've got the requested letter and photos of the garage vent elevations relative to outside grade attached. Please let me know if these sufficiently address items 2 and 3. Thanks! Jeff 1 On Thu, Oct 10, 2019 at 10:49 AM Marsha Hilmes -Robinson <MHILMESROBINSON@fcgov.com > wrote: Hi Steve and Jeff Jeff and I spoke yesterday on the phone. Here is the follow-up email regarding the comments. I've reviewed the revised permit and have a few comments that need to be resolved : 2