HomeMy WebLinkAboutDrainage Reports - 07/21/2003F
ADDENDUM
TO THE
2004 HIGH SCHOOL
FINAL DRAINAGE STUDY
- ZIEGLER ROAD WIDENING -
B E Y 0 N D E N G I N E E R I N G
1
1
1
1
ADDENDUM
TO THE
2004 HIGH SCHOOL
FINAL DRAINAGE STUDY
- ZIEGLER ROAD WIDENING -
For
2407 LaPorte Avenue
Fort Collins, Colorado 80521
Nolte Associates, Inc.
1901 Sharp Point Drive, Suite A
Fort Collins, Colorado 80525
(970) 221-2400
April 8, 2003
April 8, 2003
FC019401
Mr. Basil Harridan
City of Fort Collins
Stormwater Utilities
700 Wood Street
Fort Collins, CO 80521
BEYOND ENGINEERING
SUBJECT: 2004 High School - Ziegler Road Widening - Drainage Addendum
Dear Basil:
Please include this drainage analysis for the proposed improvements on Ziegler Road north of
Kechter Road to Celestica as an addendum to the 2004 High School Final Drainage Report. The
proposed improvements include a 15-ft and 5-ft Type R inlets with reinforced concrete pipe
outfalls going to McCellands Creek and a proposed 6' diameter manhole to be constructed over
an existing 42" RCP within Ziegler Road. Two sump conditions exist along the length of Ziegler
Road that is proposed to be widened. Drainage analyses have been performed for these sump
locations and presented below.
The low point north of the McClellands Creek crossing has been analyzed as part of the 2004
High School Final Drainage Report and the results are summarized in Table 1.
TABLE 1
Basin
Area ac
Design Point
Qlo ors
Q100 ca
502
2.04
502
4.9
12.4
503
0.88
502
3.1
8.0
502,503
2.92
502
7.4
18.9
The inlet ponding analysis for Q looy, was computed to have a depth of 0.48 ft using the urban
drainage curb opening inlet in a sump worksheet with a 10 percent clogging factor for a 15-ft.
Type R inlet. The outlet pipe (24" RCP) was sized using the StormCadd and Culvert Master
programs from Haestad Methods.
Allowable street capacities were analyzed using the City's criteria and the calculations were within
the City's guidelines.
The existing sump condition along the east side Ziegler Road, north of Rock Creek Drive has
been analyzed with the following results.
The contributing basin is 808' in length from high point to high point and includes half of Ziegler
Road (42% a 10' tree lawn and a 6' sidewalk. The area of the basin is 46,840 ft or 1.08 acres. A
NOLTE ASSOCIATES. INC.
1901 SHARP POINT DRIVE, SUITE -A
FORT COLLINS, CO 80525
970.221.2400 TEL 970.221.2415 FAX
WWW.NOLTE.COM
0
composite C was determined to be 0.82. The T, was calculated which provided the resultant I 2yr,
I ,on and I ,00yr to be 2.21 hVhr, 3.78 inft and 8.31 hvbr respectively. From these values the
' Rational Method was used to determine the Q 2yr (1.96 cfs), Q ,0yr(3.35 cfs), and the Q 100yr(8.97
cfs).
' The inlet ponding analysis for Q ,00nwas found to be 0.97 ft (0.22 feet above the top of curb)
using the Urban Drainage curb opening inlet in a sump worksheet with a 20% clogging factor for
a 5' Type R inlet. The outlet (14" X 23") HERCP was sized using the StonnCadd and Culvert
' Master programs from Haestad Methods. The 14" X 23" HERCP was used to provide adequate
clearance over the existing sanitary sewer line. The stormwater will then flow into an existing 42"
' RCP. Our calculations indicate that this pipe will adequately convey this additional flow.
Future development of the Hewlett Packard site should include rerouting the storm flow from the
' inlet to onsite detention facilities.
Consider this letter and attached information as a drainage addendum to the 2004 High School
' Final Drainage Report for the street widening of Ziegler Road. Please call if you have any
questions, or if this is acceptable, please sign and date below and forward a copy back to our
office.
Sincerely,
Nolte Associat
Il'�vu-�k
11
1
E
q
Thomas M. Oc]
Project Manage
Attachments
City of Fort Collins Stormwater Dept.
Acceptance:
Date
' NOLTE ASSOCIATES, INC.
I
1
1
SUBJECT
F'C019HP I ,GP
JOB NO. DESIGNED BY
�l3/�03
DAT CHECKED BY
M
I
I
I
q
PIN
IPG
Oil
t
- - - — — — — — — — --- — — —
— — — — — —
—
— — — ---
-
0 0
31+00
S400
56'
---
-�3at0—
32+00
35+00 too
5I
738M03::
Zbo
61
m
■
aw-wm Aw�m mv-�mw
—
ZIEGLER- ROAD
NZ -----------
NZ -
NEW-M
z
-------------------
-------------------------------------
di
NN
z
z
w co
ac
-W
w
cc
Lo
z
<
0
0
0
z
w
JI
Ucc
0
0-
LEGEND
w
cc
0
BASIN DESIGNATION
X
PROPOSED STORM DRAIN
cc
'CC,'
(4x
MANHOLE
Ir
2-yr. 0 1.96 CFS
XX.X 1D-yr. COEFFICIENT
BASIN AREA IDO-yr. 'CC,' COEFFICIENT
PROPOSED STORM DRAIN PIPE
BENCHMARKS.
HORIZONTAL CONTROL:
10-yr. 0 3.35 CFS
100-yr. 0 8.97
A
C=
PROPOSED STORM DRAIN INLET
FORT COLLINS BENCHMARK 35-94 ELEVATION 4915.79
NORTHEAST CORNER OF COUNTY ROAD 36 AND COUNTY
CENTER QUARTER CORNER
SECTION 4, T6N, R68W
CFS
DESIGN POINT
ROAD 9, ON TOP OF A CONCRETE IRRIGATION
N 10000.00
d
-------
EXISTINGV CONTOUR
STRUCTURE.
E 10000.00
m BASIN BOUNDARY
FORT COLLINS BENCHMARK 13-94 ELEVATION 4928.96
SOUTH QUARTER CORNER
w
- - - - -
- - EXISTING 5' CONTOUR
NORTHEAST CORNER OF EAST HARMONY RD. AND
SECTION 4, T6N, R68W
4930
COUNTY ROAD 9., ON TOP OF A CONCRETE IRRIGATION
N 7406.76
w
STRUCTURE.
E 10093.19
4930
4925
jLU
4925
O
IT�
T-7
- - - -
- - - -
- - - - -
-0.4W
Fo
- -
- - -
- - -
0.80%
4920
n
4920
w 99
Al -- ------
7---?T4-0
-- - - - - - - -
--- -
- - - - -
- - - - --
-1374ux
n
ci
n
n
6
c;
4915
W
ru-
4915
—vc—.
105.00'
75 DO- VC
100.00, VC
E
LOW
DINT ELEV - 4919..
0
HIGH
POINT ELEV - 4922.53
4910
-S�A
1 LOW
POINT STA - 31.+77.95
RMI
4910
i PM dLEV
- 4920.571
r... bIA - �17`1.95
I
AM
L - 0.92 1
VI-EAU---49ta-7�
A.D. - 180
I
L%-EUEV�4922.63-
A.D. =
4
I�A
X - 93.75
-0.86
K - 12500i
SHEET NUMBER
`!2 bo MN n,IN
'pig
pa
PE
SHM§
X' 6 Rid od
N N
Rio,
OIC�
R 0, R: oi6
N
oic6 oia; 0,16 '016 0,16
N
dj�
ci�,s
C;;6 ci
6
16'
Zn 2!-�
N
IN
N
N
NJ,
N;,4 ",4 -IN
N
N
MI.
ijt!
SCALE
.;o
CI!;
00 .
N
J.,
m
N
0,0
Nl,5
0 00
N.-
NE
"IF4
-I&
N
N
N NI g
N
N
,I
NI
VI
dp
L
r
7
ry
29+00 29+50 30+00
30+50
31+00 31*50
32+00 32+50 33+00 33+50 34+00
34+50
35+00 35+50 36+00
36+50 37+00 37+50 38+00 38+50
39+00 39+50
NUMBER
FC019401
I
1
1
1
1
1
I l
�I
1
1
1
APPENDIX A
Street Capacity Calculations
1
Street Capacity Calculations - Minor Storm Event (10-year)
Worksheet for Gutter Section
Project Description
Worksheet Minor Storm Event -North Ziegler Dls1&pJ Pr #)Z
Type Gutter Section
Solve For Discharge
Input Data
Slope
0.0040 ft/ft
Gutter Width
2.00 It
Gutter Cross Slope
0.0833 ft/ft
Road Cross Slope
0.0200 fVft
Spread
18.65 ft
Mannings Coefficient
0.016
Results
Discharge 8.63 cfs 0.3 QiDucTroa rAcrait ;� if. 32 CFS ALLOVIA BL6
Flow Area 3.6 ft'
Depth 0.50 ft
Gutter Depression 1.5 in
Velocity 2.39 ft/s
010 3.35 cF5
3.35 cf5 e- 4.32 cf5 o.k.
n:\...\fc019401_street_capacity_flowmaster.fm2 Nolte Associates Inc ' FlowMaster v6.1 [614o]
03/31/03 03:36:00 PM 0 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1
' .Street Capacity Calculations - Major Storm Event (100-year)
Worksheet for Irregular Channel
Project Description
Worksheet
Major Storm Event - North Ziegler Q[Stu w N. ri .
Flow Element
Irregular Channel
Method
Manning's Formula
Solve For
Discharge
'
Input Data
Slope
0.0040 ft/ft
Water Surface Elevation
0.82 ft .. 1Z,0.41. Ce.uTRO L 5
Options
Current Roughness Method Improved Lotter's Method
Open Channel Weighting Method Improved Lotter's Method
Closed Channel Weighting Method Horton's Method
'
Results
Mannings Coefficient
0.017
Elevation Range
0.00 to 1.40
Discharge 34.40 cfs o.So uvor-rro" Fwc-rag : j7. 90 GFS ALLOWASLE
Flow Area
14.6 ft'
Wetted Perimeter
51.02 ft
Top Width
50.50 ft
Actual Depth
0.82 ft
Critical Elevation
0.76 ft
Critical Slope
0.0069 f fft
Velocity
2.36 Ws
Velocity Head
0.09 ft
Specific Energy
0.91 ft
Froude Number
0.77
Flow Type
Subcritical
Roughness Segments
Start End
Mannings
Station Station
Coefficient
0+00
0+16 0.020
0+16
0+55 0.016
Natural Channel Points
Station
Elevation
(ft)
(ft)
0+00
0.82
'
0+16
0.50
0+16
0.00
0+18
0.17
0+55
0+55
0.90
1.40
aloe* 5.97 c.FS
8.51 J5 < 11.20 cis o.k.
n:%..\fc019401_street _capacity_flowmaster.fm2 Nolte Associates Inc FlowMaster v6.1 [614o]
' 03/31/03 03:49:35 PM 0 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1
Street Capacity Calculations - Minor Storm Event (10-year)
Worksheet for Gutter Section
fl
r
r
Project Description
Worksheet Minor Storm Event -South Ziegler DESI&r#j ft So a
Type Gutter Section
Solve For Discharge
Input Data
Slope
0.0225 ft/ft
Gutter Width
2.00 ft
Gutter Cross Slope
0.0833 Wft
Road Cross Slope
0.0200 Wit
Spread
13.00 It
Mannings Coefficient
0.016
Results
Discharge
8.48 efs 0.77 Rapucvgri rAc'roR :. (p.53 CFf ALLocJA81-E
Flow Area
1.8 ft'
Depth
0.39 It
Gutter Depression
1.5 in
Velocity
4.67 Ws
oro ° H. 9 ors
4.90cf5 <(o•53
cf.5.'. o.k.
nA... Uc019401_street capacity_flowmaster.fm2 Nolte Associates Inc FlowMaster v6.1 [614o]
03/31/03 03:52:51 PM 0 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1
Street Capacity Calculations - Major Storm Event (100-year)
Worksheet for Irregular Channel
I
1
Project Description
Worksheet Major Storm Event -South Ziegler DESIGN P;, 502
Flow Element Irregular Channel
"Method Manning's Formula
Solve For Discharge
Input Data
Slope __ 0.0225 ft/ft
Water Surface Elevation 0.83 ft f2.p,Lj, CoNrRot_s
Options
Current Roughness Method Improved Lotter's Method
Open Channel Weighting Method Improved Lotter's Method
Closed Channel Weighting Method Horton's Method
Results
Mannings Coefficient 0.018
Elevation Range 0.00 to 1.15
Discharge 86.68 cfs 0.77 ReOucT/oa F'ACToR 4 (oeo,7y CFS ALLowARLE
Flow Area
14.3 ft'
Wetted Perimeter
43.20 it
Top Width
42.50 it
Actual Depth
0.83 ft
Critical Elevation
1.00 ft
Critical Slope
0.0059 ft/ft
Velocity
6.06 ft/s
Velocity Head
0.57 ft
Specific Energy
1.40 it
Froude Number
1.84
Flow Type
Supercritical
Roughness Segments
Start End
Mannings
Station Station
Coefficient
0+00
0+18 0.020
'
0+18
0+44 0.016
Natural Channel Points
Station
Elevation
(ft)
(ft)
0+00
0.86
'
0+18
0.50
0+18
0.00
0+20
0.17
0+44
0.65
0+44
1.15
Qloo 3 [a.4o CFS
12.40 cf5 e GG-14 cfs .'. o.k•
n:\...\fc019401_street_capacity_flowmaster.fm2 Nolte Associates Inc FlowMaster v6.1 [614o]
03/31/03 03:59:38 PM m Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1
'
Street Capacity Calculations - Minor Storm Event (10-year)
Worksheet for Gutter Section
'
Project Description
Worksheet
Minor Storm Event - South Ziegler 2 D", &*J P}, 503
Type
Gutter Section
'
Solve For
Discharge
Input Data
Slope
0.0135 ft/ft
Gutter Width
2.00 fi
Gutter Cross Slope
Road Cross Slope
0.0833 ft/ft
0.0200 ft/ft
Spread
13.00 ft
Mannings Coefficient
0.016
tResults
Discharge
6.57 cfs o.So REouCTroa irAcroR ,�� C.06 CfrS A1.LOUJABLE
Flow Area
1.8 ft'
'
Depth
0.39 ft
Gutter Depression
1.5 in
'
Velocity
3.62 Ws
0,0 = 3. 10
c-F-5
'
3.10 c{5 < 5.26 cfs :. o.k.
1
1
n:l..\fc019401 —street _capadty_flowmaster.fm2 Notte Associates Inc FlowMaster v6.1 [614o]
' 03/31/03 04:00:05 PM 0 Haestad Methods, Inc. 37 Brookside Road Waterbury. CT 06708 USA (203) 755-1666 Page 1 of 1
Street Capacity Calculations - Major Storm Event (100-year)
Worksheet for Irregular Channel
'
Project Description
Worksheet
Major Storm Event - South Ziegler 2 t7C3t9N P4. 503
Flow Element
Irregular Channel
Method
Manning's Formula
Solve For
Discharge
'
Input Data
Slope
0.0138 ft/ft
Water Surface Elevation
0.86 it do
Options
Current Roughness Method
Improved Lotter's Method
'
Open Channel Weighting Method Improved Lotter's Method
Closed Channel Weighting Method Horton's Method
1
11
Results
Mannings Coefficient
0.018
Elevation Range
0.00 to 1.15
Discharge
76.30 cis
0.90 R&Dt)Grio^t Fgc.TbR ,^. Col.0q CFS ALLOWABLE
Flow Area
15.6 ft'
Wetted Perimeter
44.73 It
0100 - g• 00 CFS
Top Width
44.00 It
$.00 CFS G fol.O�i GFS
Actual Depth
0.86 ft
Critical Elevation
0.96 ft
Critical Slope
0.0061 ft/ft
Velocity
4.89 ft/s
Velocity Head
0.37 ft
Specific Energy
1.23 It
Froude Number
1.45
Flow Type
Supercritical
Roughness Segments
Start End
Mannings
Station Station
Coefficient
0+00 0+18
0.020
0+18 0+44
0.016
Natural Channel Points
Station Elevation
(ft)
(ft)
0+00
0+18
0.86
0.50
0+18
0.00
0+20
0.17
0+44
0.65
'
0+44
1.15
n:\..Vc019401_street_capacity_flowmaster.fm2 Nolte Associates Inc FlowMaster v6.1 [61401
04/01/03 09:03:20 AM ®Haestad Methods, Inc. 37 Brookside Road Waterbury. CT 06708 USA (203) 755-1666 Page 1 of 1
I
' APPENDIX B
Inlet Design
1
I
1
11
I
1
I
1
1
1
Project = FC01.94--2004.High School
Inlet ID =-Ziealer Road North of Rock C
Z
WP Lu WP
�[--------��- ->[---�
Yd
H .,,
led-
F'an
Gutter
gn Information (Input)
gn Discharge on the Street (from Street Hy)
th of a Unit Inlet
Width for Depression Pan
Sing Factor for a Single Unit
ht of Curb Opening in Inches
:e Coefficient
Coefficient
:r Depth for the Design Condition
of Throat (see USDCM Chapter 6, Figure ST-5)
ber of Curb Opening Inlets
a Weir
al Length of Curb Opening Inlet
)acity as a Weir without Clogging
gging Coefficient for Multiple Units
gging Factor for Multiple Units
)acity as a Weir with Clogging
an Orifice
)acity as an Orifice without Clogging
)acity as an Orifice with Clogging
Percentage for this Inlet = Qa / Qo =
Ovate r
Flaw Direction
Qo=
9.0,cfs
Lu =
5.00•ft
Wp =
3.00 ft
Co =
0.20.
H =
6.00' inches
Cd =
-`•.0.65
Cw =
'3:00
Yd==
0.97.ft
Theta=
-63.O degrees
L=T 5.00;ft
Qwi = ! .' : ;=d '.29.8: cfs
Clog-Coeff ' 1.007
Clog
Qwa = ',26:91cfs
Qoi
Qoa = 9:O cfs
Qa=90 cfs
C% = %
Note: Unless additional ponding depth or spilling over the curb is acceptable, a capture
percentage of less than 100% in a sump may indicate the need for additional inlet units.
Ziegler.xls, Curb-S
3/31/2003, 3:09 PM
Project = FC0194 -
Street ID =Ziegler Rr
GUTTER CONVEYANCE CAPACITY
School
Side walk
sheet
<----rs---> CMWNL
---
Y
Qw QX �_ Sx
x D
�Sw
T
<------------------------>
<- 'T <--------- Tx -------- >
G mer Sheet
in Discharge in the Gutter
Height
r Width
r Depression
Transverse Slope
Longitudinal Slope
ng's Roughness
ler Cross Slope
er Spread Width
er Depth without Gutter Depression
er Depth with a Gutter Depression
:ad for Side Flow on the Street
:ad for Gutter Flow along Gutter Slope
rrate Carried by Width Ts
irate Carried by Width (Ts - W)
or Flow
Flow
I Flow (Check against Qo)
ar Flow to Design Flow Ratio
valent Slope for the Street
Area
Velocity
product
Qo =
18.9 cfs
H =
6.00 inches
W =
2.00 ft
Ds =
1.52 inches
Sx =
0.0200 ft/ft
So =
0.0225 ft/ft
N =
0.016
Sw =
0.08 ft/ft
T =
18.06 ft
Y =
.0.36 ft
D =
0.49 ft
Tx =
16.06 ft
Ts =
5.85 ft
Qws =
9.3 cis
Qww =
3.0 cfs
Ow =
62 cfs
Qx =
12.7 cis
Qs =
18.9 efs
Eo =
0.33
Se =
0.04 ft/ft
As =
3.39 sq ft
Vs =
5.57 fps
VsD =
2.72 ftZ/s
UD-Inlet 0.00-vis, Street Hy
3/6/2002, 2:55 PM
Project =
Inlet ID =
Ziegler Road - D.P.502:= _
WP Lu WP
E-
-------)E-- ><- --
Gutter
gn Information (Input)
gn Discharge on the Street (from Street Hy)
th of a Unit Inlet
Width for Depression Pan
ling Factor for a Single Unit
it of Curb Opening in Inches
e Coefficient
Coefficient
r Depth for the Design Condition
of Throat (see USDCM Chapter 6, Figure ST-5)
)er of Curb Opening Inlets
a Weir
al Length of Curb Opening Inlet
:)acity as a Weir without Clogging
gging Coefficient for Multiple Units
gging Factor for Multiple Units
)acity as a Weir with Clogging
an Orifice
3acity as an Orifice without Clogging
)acity as an Orifice with Clogging
re Percentage for this Inlet = Qa / Qo =
Yd
H
Pan
9
wate r
Flow Direction
.18:9 cfs
Lu=-'
5.00;ft
Wp=:.,....
3.00ft
Co = i
0:10
H =`; , _
6.00 inches
Cw=P
:3:00
Yd = ' :
0.48�ft
Theta =S
. ' 63.0 degrees
No =
3
L = ' 15.00,ft
Qwi = 20.4 cfs
Clog-Coeff ='_' 1.31
Clog =) 0.04!
Qwa = 19.71 cfs
Qoi cfs
Qoa 19.0 cfs
Qa : -9'0 cfs
C% = R, f10o 00(%
Note: Unless additional ponding depth or spilling over the curb is acceptable, a capture
percentage of less than 100% in a sump may indicate the need for additional inlet units.
DP_502.xis, Curb-S 4/1/2003, 9:19 AM
11
I
1
1
1
i
1
1
APPENDIX C
1
Storm Drain Design
1
1
1
1
1
1
1
i
Ci
1
W
J
Z
N
Z
2
N
Z
I
N
O
�
U
Z
W
t
O
O
u
N
J
4d
J
Z
r
o
a
Q
N
m
O
E-
a:
U
N
O
p
m
O
W
p
NUJ
N
N
E
H
N
cl
N
O
�
(7
Q
d
U
O
-
o
U
Q
O
—L
c}
M
N
O
O
O
a
.
W
U
W
N
p
�
W
�
n
N
I
CY
L'i
Q
Z
Z
O
N
Z
F
C5
H
H
Li
U
Li
Uj
?i
Q
Q
R
W
S
a
d
X
0
N
Scenario: Base
I
1
11
Node Report
Label
Total
Rim
Hydraulic
Hydraulic
Sump
Description
System
Elevation
Grade
Grade
Elevation
Flow
(ft)
Line In
Line Out
(ft)
(cfs)
(it)
(ft)
MH ST2
41.30
4,921.17
4,919.74
4,919.74
4,911.01
Label from RBD UDSEWER Discription
NZ -INLET
8.97
4,920.80
4,920.30
4.919.82
4,917.15
Proposed Inlet
NZ-MH
50.27
4,920.32
4,919.37
4,918.84
4,910.73
Proposed 6' Manhole
MH ST1
' 50.27
4,920.91
4,918.14
4,918.14
4,910.38
Label from RBD UDSEWER Discription
Title: N Ziegler Project Engineer. JEP
n:%fc0194NstormcadV-ziegler.stm Nolte Associates Inc StormCAD v4.1.1 [4.2014a)
' 04/02/03 03:59:26 PM O Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA +1-203-755-1666 Page 1 of 1
r-
0
Q
d
Q
T d S
M CD N
rn rn rn
.u)
3
r r v
v O
...
0) M of
iC75
0) 0) m
co m ao
m c
r ao ci
dr o_
o mi o
my
rn m
c
0)3—
m
v a v
0 w
c+) o r
T d C
O N N
@Z
m m d�
O O 0)
N N
O O
w J
a
•t a
Uv
co co
C
0) O) CO
C `
0) 0) 0)
C
m r O
O a r
m N C
'v
� r O
aiCD
rnrno)
w
a a v
0 co N
N W N
M— ^
m U 0
V O
d
Q>
O r r
f7 q N
y0 (D 3 N
'- m O
F0- >LL`U..
V Lon
0)
fD -IT
_T
O O •f
— U
(D r N
LL a U
M
m "
U
0)
m <7 c7
c
O O O
E c
c
O O O
m
L
C
U
d
—0 N
C
U t7 U
CDcn V)
C X C
N R N
0
d
0j
OOO
L
O N O
p
O r O
c v
N r N
J
N (D CO
E
m
d d
c 0
_
= 2 F
3z
cn
0
z z
E
d
N w
y 0
O) Z
Z
D
Z Z
U
0_
w
m=
m
Q X m
0
4
a
J
Y
W
3
tu
0
4
00
ac
to
H
r
O'
Us
m
H
O
O
O
v)
N
r
0
N
t
N
Z)
m
0
CD
O
H
U
U
c
0
E
N
m
O)
d
N
c a
ar
€� m o
d N O
N m ")
ZCDo
u o
F C O
o�>>
(n N C C
� I
LUa
Io
¢z
no
cn a
N O
O K1 O
4) O rn
a cm co
a J- 00
al O
N N C G
co
N ',d. O
O Oj
ai O
a CO 00
OD
¢ � 0
o�>>
fN N C C
i
w
so
-1
1
LF]
u
L_J
L
1
1
`o
e
b
0
❑
y y ^.
g n e O P N a N 0 n n O e YI V 17 m !1
8 wm mmmb$mmm4mm$mmmmsm
w U?
f f Y v a f a a a Y f a a v a a f a v v f a v a v d d v c i a+ v f a a v v a � a
e
T
N O n n N O g a O N^ 00v
n N N g Y 1� V O O Ifl ppc
p C
''e@zmm&Wm$BmmRm$$xm�mmmm$mmm��mmmm$mmmcmm,
W U 7
a Y Y a v a f a O f a o a f Y e v a o a f a v a a v a a Yea f a a a Y va a f a a a v a f Y
y
10'1 O n A A A A n' a A n NmaN0o @aA ONNNN0 NA'WN
14
N
eP
gN mN moO $momO $n m0
g
o a f a a e Y d a f a o a v a a a d a a v a v f
f
m n oi,
mv
(4,4
q WW$90 mmOOm N p 8 N OOGp O Oa 0 O O O
s
s
OOn�a
eGaGa
OGnGa ena
a$Coa
OpO O C0 0 ry h
pp
Wrva
PGav
$SaIRD
$$Oe $$ua
0NmN14a
$$a
OnesY
♦pWaOpa
pmgOd
qppY
Pm $O
pO$ymsl
Wd
$am
qpe OerSR.
OOW$ 0m$$ QAd qqa
$ oW
pm$
O0v qgY Wma WWa
Oppmarv�i
Wa
�❑W
O
E C CCO
WOI1 $ O$ 0192 w b V 9$N2 N n N 0
OO OYI
5 z�'
n nO IOV OO
Q rm lm'1
ss m O N zz O 0 O IV yy N IV f1 h OI OI n YI 17 O IV m O m m N W 16 Oj Np y Y
oma v mm i,m $$�$$�$�$m
Y
pt
oa,oe oaf of oa favpf a dfva a fa aoa + f oa
E
O O O W W m N m (p7
q n n m P m $ O A N A O N$ g y A A p 0 IO A z Y A A A N n n W r g m A O N O $ a N N$ O
O
y
O
qq qq Vq p y
N
IR P O$ 0 W$$ O O O m g O O O 0 O O 0 0 m p q O 0 0 O 0 0 O m O 0 O yqq P 16 W O 8 O
O
>>
f e a e v O W m
a f e e a e O a f a v O e e Y O e Y O O V Y
p
W
❑
f O a e f O Y Y e e e e O a Y
O O$ n r f qq qq
C n N n N m WOryN m a O
N O ANoo
N
aNb m10p $Oy m0 grygw
�$mmm O a mmm a
m mo m m m $$
$q
jC
Ye e a e OO Om
e f Y a a e f O eO Y O Y
e
p
^m
8 S
nb b d bNm No.
N ry
m
E
n m N o o n N o 0 0 0 -ono a n m a o n m a$ n o "�, $ o �i, o o s o$ o
m N a n ry m ry r m m N r n +, r o e m f$ ry W a o ry
OO a N 0' 0 on N
$
9 yp .I
lV YI f O OO N O m YI C A ry N v N P roi,
N
O'
U
0
n n n
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o P o 0 0 0 0 0 0 0 0 0 0 0 0
d d d d d d d d d d d 0 0 0
0
0
d d d d d 6 d d d d d d d d d d d 6 d d d d d d d d d d 6 d d d d d d d d d
d
a�
5 5 fi fi
fi 5 5 fi e 5 5 5 5 5 5 S
m
ry c c c c_ A 5 f 5 5 5 5 5 5 fi 5 5 fi 5 5 fi 5 5 5 5 5 5 fi 5 5 fi 5 5 fi 5 5
fi
o
3
$9.N W$oOmy�m9.n$�ug$in 9�$�R g.$9i$gi �R$$�,R$m$r 9. gir aW 9im$n$n$$nm9io
momma000�o$$oS8o
9i
e_
s8od0 o d doss88S$88sss8s$$$
ddd oo 6
s
SN�
U
d d d d d d d d o d d d d d d8$ d0
6 do dedo$dodd o
op ^^ m 1 n N pppp9 6 P N O Y1 N O$ O ry
qS p W O 0 n P$ 0 N rm m N N O e^ O
a bp N O INs 6 m N N a
N
J
y�y m �
S
YNI A 1ND
N n N '^) N a N n m N O N N m N N N N m 0 N m' 0 N m a N N N A N
N A
E
g8
a N a
mO_s__I
a❑yW
W
Da❑
2 2doao
�❑ ao mO
W
O
❑s_❑Ss
❑om%❑S=T
ch%T %a %m26 �❑ m❑ m❑ m❑O
❑To' ❑T ❑ ❑ ❑ ❑a❑mm❑ m❑am❑ m❑ m❑
❑ ❑ ❑oOs ❑O ❑tjs
❑ Om❑ ❑ Om❑ ❑�omom❑ om❑�coo
❑
F
E
E o
me
g z
g€ y
E o u m N 3^ o e 8 A o a o ^o 0
0
0 '0
aamaaammaa�aa%ammaam�aaa��m��mamm���am�a���aa��
0 a0 o
sao==s===mN===N ==n aN===
y
4
9 SaaS�'T'd
S S S O O W O ry O n P q e
dN nmm� m� o �iiiS��13 ��g
��dSB
og o 000800o80'an oo �
e
ag
o% m w o m y% m N woo wwwwwo 88g gS888
g
9
' ra esi+gn Calcri _`ons Circu ar Ou all
Project : F1
Project Name: Ziegler
Calculated By. JEP
Date: 3/26/2003 BEYOND ENGIN EERI N G
Calculations per Urban Drainage and Flood Control District
Section 5.6.2 Required Rock Size and Section 5.6.3 Extent of Protection
Location: Storm Drain System H Outlet McClellands Channel.
Outfall Pipe Diameter, in:' _ ` Velocity, ft/s: - 76:59 .
Qtm cfs, t - ,18l9' Depth of flow, ft:" 2`- _
Tailwater depth, ft: - - 0.5 Froude Number: 0.82 supercritical
Where, F = V/(gY)os
F>0.80, supercritical flow
F<0.80, subcritical flow
Required Rock Size:
a. Q/D2.5= W. Q/D1.5= n/a
b. YM-- n/a
C. (d50(D)(YM)t.2/(Q/D2.5) = 0.023
From Figure 5-7,
Use Type i-7u%a;==: -14Riprap
d5o=L :-n/a`.':,,@inches
If the flow in the culvert is supercritical, substitute D. for D.
Where:
D. = t/2(D + YJ
Therefore:
D,= 2.00 ft
a, Q/D a5= 3.34 Q/D.1.5= 6.68
V. YMi= 0.25
c'. (dso/DJ(Y/D J'.2/(Q/D.2.5) = 0.023
From Figure 5-7,
Use Type 'M -' 9 Rlprap
so 12�;T,aJ inches
Extent of Protection:
L = (1/(2tanO))(A,/Y, - W)
Where:
.1/(2tan0)=.2}3;-per;Aigrue`5=9�_f ;�
A. QN Where, V = acceptable velocity, 5.5 fps
A� 3.44 ft2
Therefore:
Calculated L= 29.24 ft
Cheat Results:
L> 3D
•L < 1 OD
• When Q/D3> 6
Maximum Depth:
D = 2d5o
Riprop Iidth:
W=3D
Minimum = 6 ft
Maximum L = 20 ft
UseL= 10 feet
Use D = 24 inches
Use W = 6 feet
' APPENDIX D
Charts, Tables & Graphs
I
I
I
1
I
1
1
I
I
I
L
C
C
L
C
MAY 19".
a
S 0. 4 0/go
FzO-5
_T
BELOW MINIMUM
>- ALLOWABLE
LSTREET GRADE
X
0 2 4, 6 8 10 12 14
SLOPE OF GUTTER
Figure 4-2
REDUCTION FACTOR FOR ALLOWABLE GUTTER CAPACITY
Apply reduction factor for applicable slope to the theoretical gutter capacity to obtain
-allowable gutter capacity,.
(From:-U.S. Dept. of Commerce, Bureau of Public Roads-, 1965)
4-4: DESIGN CRITERIA:' ....
DRAINAGE CRITERIA MANUAL
RIPRAP
E
i
8 = Expansion Angle
�1
.1 .c .a .4 .6 .7 .8
TAILWATER DEPTH/.CONDUIT HEIGHT; Y t / D
FIGURE 5-9. EXPANSION FACTOR FOR CIRCULAR CONDUITS
i l-]5-82
URBAN DRAINAGE & FLOOD CONTROL DISTRICT
DRAINAGE CRITERIA MANUAL
RIPRAP
Z4
n
n 4t
0
is
0
dF
co
AT
N
I
IT�PE� L
Yt/D I.O
Use Do instead of D whenever flow is supercritical in the barrel.
**Use Type L for a distance of 30 downstream .
FIGURE 5-7. RIPRAP EROSION PROTECTION AT CIRCULAR
CONDUIT OUTLET.
11-15-82
URBAN DRAINAGE 8 FLOOD CONTROL DISTRICT
:Onsultants
z7/
CLIENT 'N\\e1N.� Oe s; f 14 O S' i 9✓�S
PROJECT % L0. L II-0..Ir rJ� CAUTIONS FOR si0
MADE BY= DATE-45 CHECKED BY DATA
SHEET OF �
4z`i Z
S'T 3
--_._--r
z/
REPORT OF STORM SEVER SYSTEM DESIGN
USING UDSEWER-MODEL VERSION 4
DEVELOPED
_- BY
JAMES C.Y..GUO ,PHD, PE
DEPARTMENT OF CIVIL ENGINEERING, UNIVERSITY OF COLORADO AT DENVER
IN COOPERATION WITH
URBAN DRAINAGE AND FLOOD CONTROL DISTRICT
DENVER, COLORADO
•'* EXECUTED BY DENVER CITY/COUNTY USE ONLY ....................
ON DATA 10-15-1993 AT TIME 09:22:52
* PROJECT TITLE :
COUNTY ROAD 9 STORM SEWER
"* SUMMARY OF HYDRAULICS AT MANHOLES
"------------------------------------'
MANHOLE
CNTRBTING
RAINFALL RAINFALL
DESIGN
GROUND
WATER
COMMENTS
1D NUMBER
AREA * C
DURATION INTENSITY
PEAK FLOW ELEVATION ELEVATION
-----------
--- -
_ MINUTES INCH/HR
CFS
FEET
FEET
15.00
1.90
5.00 4.90
9.30
21.25
20.45
OK
14.00
13.00
1.90
6.53
5.00 4.90
5.00 4.90
9.30
32.00
21.25
21.06
20.41
22.10
OK `1
NO P51
12.00
6.53
5.00 4.90
32.00
21.06
21.93
�`
11.00
8.43
5.66 4.90
41.30
22.00
20.24
NO
OK
10.00
8.43
5.94 4.90
41.30
21.90
19.90
OK
9.00
8.43
9.82 4.90
41.30
19.61
18.14
OK
8.00
7.00
14..10
0.00
9.95 4.90
69.10
20.00
17.36
OK
17.00
8.43
0.00 0.00
7.88 4.90
69.10
41.30
20.50
20.60
17.51
OK
OK MEANS WATER ELEVATION IS LOWER THAN GROUND ELEVATION
19.05
OK
* SUMMARY OF SEWER HYDRAULICS
NOTE: THE GIVEN FLOW DEPTH -TO -SEWER SIZE RATIO= .8
---------------------------------------
ID BENSBER
.
SEWER
------------'-----------------'-
REQUIRED
SUGGESTED
EXISTING
NUMBER
UPSTREAM
DTREAM
SHAPE
DIA(HIGH
DIA(HIGH
DIA(HIGH)
LIDTHID
---------------'--'----:-
No
IDNO
(IN) (FT)
(IN) (FT)
(IN) (FT)
(FT)
19.00
20.00
17.00
9.00
ROUND
42.93
48.00
42.00
0.00
21.00
10.00
17.00
ROUND
42.93
48.00
42.00
0.00
22.00
ll.OD
12.00
10.00
ROUND
.42.93
48.00
42.00
0.00
23.00
11.00
ROUND
30.79
33.00
30.00
0.00
24.00
13.00
14.00
12.00
11.00
ROUND
30.58
33.00
30.00
0.00
18.00
9.00
8.00
ROUND
12.93
15.00
24.00
0.00
17.00
8.00
7.00
ROUND
42.93
48.00
42.00
0.00
25.00
15.00
14.00
ROUND'
47:32
48.00
42.00
0.00
ROUND
13.26
15.00
24.00
0.00
uttMSION-UNITS FOR ROUND AND ARCH SEWER ARE IN INCHES
IMENSION UNITS FOR BOX SEWER ARE IN FEET
EOUIRED DIAMETER WAS DETERMINED BY SEWER HYDRAULIC CAPACITY.
SUGGESTED DIAMETER WAS DETERMINED BY COMMERCIALLY AVAILABLE SIZE.
FOR A NEW SEWER, FLOW WAS ANALYZED BY THE SUGGESTED SEWER SIZE; OTHERWISE,
EXISITNG SIZE WAS USED
'------------------------------------
SEWER DESIGN FLOW NORMAL NORMAL CRITIC CRITIC FULL FROUDE COMMENT
ID FLOW 0 FULL O DEPTH VLCITY DEPTH VLCITY VLCITY NO.
NUMBER CFS CFS FEET FPS FEET FPS FPS
-
------------------------------------
- -----------------------
19.0 41.3 39.1 3.50 4.29 2.00 1.64 4.29 0.00 V-OK
20.0 41.3 39.1 3.50 1.29 2.00 1.64 4.29 0.00 V-OK
21.0 41.3 39.1 3.50 1.29 2.00 5.64 4.29 0.00 V-OK
22.0 32.0 29.9 2.50 6.52 1.93 7.88 6.52 0.00 V-OK
23.0 32.0 30.5 2.50 6.52 1.93 10.17 6.52 0.00 V-OK
24.0 9.3 48.5 0.59 11.91 1.09 23.49 2.96 3.21 V-OK
18.0 41.3 39.1 3.50 4.29 2.00 7.27 4.29 0.00 V-OK
17.0 69.1 50.4 3.50 7.18 2.61 8.99 7.18 0.00 V-OK
25.0 9.3 45.4 0.61 11.35 1.09 39.30 2.96 3.00 V-OK
FROUDE NUMBER=O INDICATES THAT A PRESSURED FLOW OCCURS
----------------------------------------------------------------------
SEWER
SLOPE
INVERT ELEVATION
BURIED
DEPTH
COMMENTS
ID NUMBER
UPSTREAM, ONSTREAM
UPSTREAM
DNSTREAM
----- --__.X__
(FT)
--------------------
(FT)
(FT)
(FT)
19.00
0.15
11.39
10.64
-----------------------------
5.71
5.47
OK
20.00
0.15
12.14
11.39
6.26
5.71
OK
21.00
0.15
12.25
12.15
6.25
6.25
OK
22.00
0.53
13.64 .
12.26
4.92
7.24
OK
23.00
0.55
13.64
13-64
4.92
4.92
OK
24.00
4.58
12.80
12_25
6.45
7.75
OK
18.00
0.15
10.64
10.59
5.47
5.91
OK
17.00
0.25
10.55
10-23
5.95
6.77
OK
25.00
4.00
12.80
12.80
6.45
6.45
OK
OK MEANS BURIED
DEPTH
IS GREATER
THAN REQUIRED SOIL
COVER OF
1.5 FEET
SUMMARY OF HYDRAULIC GRADIENT LINE ALONG SEWERS
-------------------------------------------------------------------------------
SEWER SEWER SURCHARGED CROW ELEVATION WATER ELEVATION FLOW
ID NUMBER LENGTH LENGTH UPSTREAM DNSTREAM UPSTREAM DNSTREAM CONDITION
FEET FEET FEET FEET FEET FEET
- -- -
------------------------------------------------------ -----
19.00 500.00 500.00 14.89 14.14 19.05 18.14 PRSS'ED
20.00 500.00 500.00 15.64 14.89 19.90 19.05 PRSS'ED
21.00 70.00 70.00 15.75 15.65 20.24 19.90 PRSS'ED
22.00 260.00 260.00 16.14 14.76 21.93 20.24 PRSS'ED
23.00 0.10 0.10 16.14 16.14 22.10 21.93 PRSS'ED
24.00 12.00 12.00 14.80 14.25 20.41 20.24 PRSS'ED
18.00 33.00 33.00 14.14 14.09 18.14 17.36 PRSS'ED
17.00 130.00 130.00 14.05 13.73 17.36 17.51 PRSS'ED
25.00 0.10 0.10 14.80 14.80 20.45 20.41 PRSS'ED
PRSS'ED=PRESSURED FLOW; JUMP=POSSIBLE HYDRAULIC JUMP; SUBCR=SUBCRITICAL FLOW
SUMMARY OF ENERGY GRADIENT LINE ALONG SEWERS
----------------------------------------------------------------------------
UPST MANHOLE SEWER JUNCTURE LOSSES DOWNST MANHOLE
SEWER MANHOLE ENERGY FRCTION BEND BEND LATERAL LATERAL MANHOLE ENERGY
--ID-NO ID NO. ELEV F7 FT K COEF LOSS FT K COEF LOSS FT
ID
19.0 ---0.00-----
FT
17.00 19.34 0.84 0.25 0.07p.pp_---9.00_-
21.0 11.00 20.79 0.84 0.05
18.43
0.01 0.00 0.00 17.00
21.0 71.00 20.52 0.12 0.75 0.21 0.00 0.00.
19.34
34
19.19
10.00
23.0 13.00 22.760.00 0.00 11-00
0.00
20.52
24.0 0.25 0.16 0.00 0.00 12.00
14.00 20.55 0.02 0.05 0.01 0.00
22.59
0.00 11.00
18.0 9.00 18.43 0.06 0.75 0.21 0.00 0.00
17.0
20.52
8.00
8.00 18.16 0.61 0.05 0.04 0.00 0.00 7.00
25.0 15.00 20.58 0.00
18.16,
17.51
0.25 0.03 0.00 0.00 14.00
20.55
.BEND LOSS =BEND K* FLOWING FULL VHEAD IN SEWER.
LATERAL LOSS= OUTFLOW FULL VHEAD-JCT LOSS K*INFLOW
FULL VNEAD
FRICTION LOSS=O MEANS IT IS NEGLIGIBLE
OR POSSIBLE ERROR DUE TO JUMP.
FRICTION LOSS INCLUDES SEWER INVERT
DROP AT MANHOLE
NOTICE: VHEAD DENOTES THE VELOCITY
HEAD OF FULL FLOW CONDITION.
A MINIMUM JUCTION LOSS OF 0.05
FT WOULD BE INTRODUCED UNLESS LATERAL K=O.
FRICTION LOSS WAS ESTIMATED BY BACKWATER
CURVE COMPUTATIONS.