Loading...
HomeMy WebLinkAboutDrainage Reports - 04/08/1980 (2)STORM WATER DRAINAGE REPORT FO P THE RAINTREE P.U.D. IN THE CITY OF FORT COLLINS, COLORADO APRIL 1980 INU16 TARANT() STANlON & 'IAG(.>:. ('ONSUITING ENGINEERS s•..�.�o.. R1 V0I I NJ il1LOR ADO .. .. TARANTO STANTON '& TAGGE CONSULTING ENGINEERS Apri-1 8, 1980 Re: Stormwater Drainage Report Raintree P.U.D. ' City of Fort Collins Engineering. Services Department 300 LaPorte Avenue Fort Collins, Colorado 80522 Attn: Mr. Mauri Rupel Mr. Bob Smith 1 Gentlemen: Submitted herein is the stormwater drainage report on the Raintree Planned Unit Development for your review. If you should have any questions concerning this report, ' please do not hesitate to contact this office. Sincerely, ' John P. Cotten Project Engineer Larry E. Stanton, P.E. TARANTO, STANTON & TAGGE ' CONSULTI14G ENGINEERS JPC:cs RD S� •... ` Q °���SVEq �O y� . /y .l• 4 yQ 1 14114 yz O V 0 NY 1j 1 �yy ~� O 112 W. 11TH AVE. 6412 S. COLLEGE AVE. . P.O. BOX 703 HOLDREGE, NE 68949 FORT COLLINS, CO 80525 HAYDEN, CO 81639 (308) 995.6677 (303) 226-0557 (303) 276-3834 \l DRAINAGE REPORT for the RAINTREE PLANNED UNIT DEVELOPMENT FORT COLLINS, COLORADO iI. INTRODUCTION ' The proposed development is a 37.39 acre tract located at the northwest corner of.Shields Street and Drake Road; Southeast Quarter, Section 22, Township 7 North, Range 69 West. The purpose of this report is to provide a method of conveyance and disposal of storm runoff from the proposed development. Items to be -covered in this report are as follows: 1. Design.Criteria 2. Historic and Developed Runoff '. 3. Storm Sewer Design. 4. Initial and Major Storm Runoff 5. Design Calculations ' II. DESIGN CRITERIA The design criteria.for this report was based upon.the guide- ' dines and requirements put forth in the City of Fort Collins' Storm Drainage Criteria manual and the Urban Storm Drainage Criteria manual published by the Denver Regional Council of Governments. The "Rational Method" was used to determine all runoff flows from and within the site; The following runoff coefficients were used in ;the analysis':" 1 Undeveloped Land C 0.20 ' Developed Residential C = 0.54 Runoff coefficients.are adjusted -for composite areas. ' III. HISTORIC AND DEVELOPED RUNOFF ' The proposed site was historically_.a portion of sub -basin of'the Spring -Creek drainage area. This'area drained northerly and northwesterly into Spring Creek. When the New Mercer ditch ' was constructed a portion of 'the sub -basin to the south of the ditch was cut off from Srping',Creek and the drainage from this area became tributary to the ditch This continued until Shields Street and Drake Road were constructed, which further ' cut down the area by redirecting. the flow on the south side of Shields Street. There is a high point in' Drake Road approximately one thousand ' feet.(1000') west of the.intersection with Shields Street. The drainage splits at this point, and the westerly portion flows along Shields to Spring Creek... The eastern portion drains to ' the Drake -Shields intersection where it enters into the Colorado State University farm -irrigation system. From the time that these improvements were completed, until the ' present, only that parcel of"land which includes.Raintree P.U.D. and the eight acre commercial site drained directly into the New'Mercer ditch. The proposed development will collect the runoff which is ' presently entering the New Mercer ditch in catch basins and pipe the flow under the ditch to two detention.ponds. Release 1 t ' from•the ponds .wi11 be through .outlet structures into a common ' discharge line which terminates at Spring Creek. In order to allow the main detention to be placed between the two ditches and still keep the.water depth reasonable, the upper portion of -the -site has its own detention system with a ' controlled release into the main ponds. This includes Basins . "F" and "G'.' which are detained :i.n.Ponds "C" and "D", as well ' as a stub out in 'the storm sewer,.for therelease from the outlot area (See Exhibit "A"). )\•four c.f.s. release rate from on- ' ' site detention in this outlot area -has been allowed for in sizing the storm sewer. The site contains a total of`37.39 acres,.of.which 35.00 acres drains to detainage. The remaining 2.39 acres (6.8%) drains into Drake Road Shields Street. or Detention pond sizing was accomplished by the.accumulated run- off method. All runoff was calculated using the rational method ' as described in the City of Fort Collins Storm Drainage Design criteria. Detention pond volumes, -release rates, high water . surfaces, etc. are shown on Exhibit "A" and in the design drawings. ' for the:100 is 97.40 The total developed runoff year storm c:f.s. The two year undeveloped runoff is 14.31 c.f.s. ' IV. STORM SEWER DESIGN In order to convey the drainage across the ditch to the deten- tion ponds and also to,prevent.inundating the streets, a storm ` sewer system was designed. Since the 100 year storm had to be 1 carried under the ditch in the pipes, a pressure system was ' used to maintain reasonablc.pipe sizes. Pipe sizes were deter-. mined by.a computer program using Bernoulli's.equation. A discussion of the p.rogram.is'included in the calculation section of.this report. In areas where the flow rates and elevations ' allowed, gravity flow was used. Also because of the high flow`requirements.a curb opening type of inlet with a nine inch-(9") throat was designed. The calcu- lations for this inlet are also included in the calculation section. These inlets have been sized to accept the peak runoff from the 100 year storm.', V. INITIAL AND MAJOR STORM.RUNOFF i In order to protect the development against recurring minor damage due to uncontrolled runoff and to reduce maintenance t costs, a two year'runoff period was used.to analyze the poten- tial for damage.' A 100 year,return period was used to.analyze for entire development. The. the potential for major damage the limiting criteria for the .initial storm on local streets was ' that no curb -topping would be, allowed;, for the major storm the maximum depth allowed.at'the.centerline would be 6": The amount of runoff was determined at changes iri.grade and at ' all intersections. The runoff was then routed to the detention pond. Theoretical street capacities were calculated and then reduced to an allowable capacity by the appropriate reduction ' factor. Where runoff exceeded the allowable runoff, inlets and storm sewer was designed to be installed: ' i