Loading...
HomeMy WebLinkAboutDrainage Reports - 03/22/1996Final Drainage Report for Landings Office Park P.U.D. City of Fort Collins, Colorado October 27, 1995 Prepared For: Lagunitas Company Prepared By: Northern Engineering Services, Inc: 420 South Howes, Suite 202 Fort Collins, Colorado 80521 (970)221-4158 Fax (970)221-4159 Project Number: 9516.00 Fourth Final Submittal Northern Engineering Services, Inc. October 27, 1995 City of Fort Collins Stormwater Utility 235 Mathews Fort Collins, Colorado 80522 1 RE: Landings Office Park P.U.D. ' Fort Collins, Colorado Project Number: 9516.00 Dear Staff: Northern Engineering is pleased to re -submit this Final Drainage Report for the Landings Office Park P.U.D. for your review. We have addressed the comments contained on the Project Comment Sheet dated October 24, 1995. ' This report was prepared in compliance with technical criteria set forth in the City of Fort Collins Storm Drainage Design Criteria and Construction Standards manual. If you should have any questions or comments as you review this revised report, ' please feel free to contact me at your convenience. ' Sincerely, NORTHERN ENGINEERII INC. r ..8 0• Hy •.'gam Mary B. Wohnrade, P.E�• 30325 420 S. Howes, Suite 202 • Fort Collins, Colorado 80521 • (970) 221-4158 • Fax (970) 221-4159 ►.4 w E4 z W LoLl U 0 CL E li I: ' Final Drainage Report for Landings Office Park P.U.D. I. GENERAL LOCATION SITE DESCRIPTION General Location This report summarizes the results of a storm drainage investigation for the proposed Landings Office Park P.U.D. site. The project is located in the NW Quarter ' of Section 36, Township 7 North, Range 69 West of the 6th Principal Meridian in Fort Collins, Colorado. The project is bounded by Horsetooth Road to the north, Boardwalk Drive on the south, Landings Drive on the east, and JFK Parkway to the west. (See Vicinity Map). ' Site Description The 3.19 acre site is located in southeast Fort Collins, is currently residential and vegetated with native grasses and weeds. The surrounding land use patterns are residential (The Landings P.U.D. and High Point P.U.D.) to the east, commercial to the south (U.S. Post Office) and west (ShopKo P.U.D.) and currently undeveloped land to ' the north. The site is in the vicinity of the Larimer County Canal No.2 to the north, south and east. ' II. HISTORIC DRAINAGE Major Basin Description ' The project is located in the McClellands/Mail Creek Drainage Basin. The proposed site drains to the Larimer County Canal No. 2 according to the °Final Drainage Report for Heart Special Improvement District', dated December, 1984, ' revised January, 1985 by Engineering Professionals, Inc.. The report gives a maximum allowable release rate for the site of 0.87 cfs/acre. 11 Landings Office Park P.U.D. October 27, 1995 Final Drainage Report Page 2 ' II. HISTORIC DRAINAGE. con't ' Historic Drainage Patterns A ridge traversing east -west divides the site, with the majority of stormwater runoff flowing to the south-southeast to Boardwalk Drive. The historic drainage pattern of the site is from, north to south-southeast and, south to northeast (as predicated by the ridge) by overland flow at slopes ranging from 3.2% to 4.9%. There is no off -site runoff entering the site due to the ridge and street boundaries. There is an existing 4' Type R Curb Inlet located at the northwest comer of Boardwalk and Landings Drives. A 15" diameter pipe extends from the inlet, southeast under Boardwalk and daylights into a vacant lot east of the U.S. Post Office. A 15' Type R Curb Inlet is located at the northeast corner of JFK Parkway and Boardwalk. Stormwater flows from this inlet west, under JFK Parkway to another 15' Curb Inlet and continues north to the East Detention Pond of ShopKo P.U.D.. There are no existing drainage structures or irrigation laterals on the site. III. DEVELOPED DRAINAGE Developed Conditions The proposed development of the site includes 8 commercial buildings with a central parking area and includes all utilities. Three (3) drive entrances will serve the site off of JFK Parkway, Boardwalk Drive and Landings Drive. Design Criteria and References Drainage criteria outlined in both the City of Fort Collins Storm Drainage Design Criteria Manual.(SDDCM) and Storm Drainage Criteria Manual by the Urban Drainage and Flood Control District have been used for this Preliminary Drainage Study. The Final Drainage Report for Heart Special Improvement District" by Engineering Professionals, Inc. has also been referenced. ' Landings Office Park P.U.D. October 27, 1995 Final Drainage Report Page 3 ' III. DEVELOPED DRAINAGE con't Hydrologic Criteria The Rational Method was used to estimate peak stormwater runoff from the proposed development site. An initial 2-year design storm and major 100-year design storm was used to evaluate the proposed drainage system. The culvert under the Boardwalk drive entrance has been sized for the 10-year storm. Rainfall intensity data 1 for the Rational Method was taken from Figure 3-1 of SDDCM. Hydraulic Criteria The City of Fort Collins Storm Drainage Design Criteria has been used for all hydraulic calculations. ' General Drainage Concept The majority of on -site developed stormwater runoff will be conveyed through the Landings Office Park site by overland flow, vertical curb and gutter, sidewalk chases and a drainage culvert to two (2) proposed detention facilities located in the northeast and southeast corners of the site. From. the detention facilities, stormwater will be conveyed to the Larimer County #2 Canal via either off -site swale or curb and gutter. Specific Details iAccording to the Heart Special Improvement District Drainage Report, a total of 98 acres above the Larimer Canal drains to the irrigation/stormwater ditch. The staff ' at the City of Fort Collins Stormwater Utility Department recommended the canal convey a total discharge of 240 cfs, 155 cfs of irrigation flow and 85 cfs of stormwater flow. The 0.87 cfs/acre maximum release rate was calculated using these factors (85 cfs/ 98acres). The Landings site is part of the 98 acres tributary to the Larimer Canal and therefore would require detention of stormwater to the required rates. Due to the topography of the site, it will not be feasible to route runoff from the entire site and adjacent streets to detention facilities to be released at the allowable rate of 0.87 cfs/acre. I Landings Office Park P.U.D. Final Drainage Report Specific Details, con't October 27, 1995 Page 4 The release rate specified by the Heart Special Improvement District report is not the only criteria to be met in discharging stormwater from the site, there are two additional requirements. First, the release rate from Basins' D2 (undetained) and D4 (detained) combined should not exceed 2.75 cfs at an existing inlet located approximately 170 feet north of the site in the west flowline of Landings Drive. Shear Engineering ' calculated this (historic) flow as part of the Jetty P.U.D. in 1986. The same site was developed as High Pointe P.U.D. in 1989 (See excerpts from High Pointe Drainage Report in Appendix). The developed 100-year flow from these basins (D2 and D4) at Design Point D10 is 3.1 cfs which exceeds 2.75 cfs but is not excessive and is anticipated to have minimal impact on street and inlet capacities. It is not possible to capture any additional runoff from these basins, in addition, a transverse inlet is ' proposed across the drive entrance off of Landings Drive to intercept any last runoff prior to leaving the site. Secondly, the release rate from Basin D3 must not exceed 2.76 cfs at an existing 15' curb inlet located at the northeast comer of JFK Parkway and Boardwalk ' Drive. The inlet was installed as part of the ShopKo P.U.D. (JFK Parkway Improvements) and designed by TST, Inc, Consulting Engineers in 1993 (See letter dated August 10, 1993 in Appendix). Runoff entering the inlet is conveyed to the East Detention Pond of ShopKo and eventually released to the Larimer County #2 Canal. The developed 100-year flow calculated at Design Point D3 from the Landings site is 2.3 cfs and therefore is below the anticipated flow calculated by TST. The existing 15' curb inlet is capable of intercepting the anticipated 100-yr flow of 2.3 cfs. The Landings site is divided into three release points discharging stormwater into three separate directions all of which are conveyed to the Larimer County #2 Canal. As previously mentioned, runoff from Basin D3 will be conveyed to the ShopKo P.U.D. due to the presence of an existing curb inlet. Runoff from Basins' D2 ' and D4 is conveyed north down Landings Drive to an existing curb inlet and then through Pond 'A' of High Pointe P.U.D. to the Larimer #2 Canal. Runoff from Basins' D1, D5, D7,D8 and D9 will be routed to the proposed Detention Pond D1 located in ' the southeast corner of the site. The pond will release into an existing 4' curb inlet located at the northwest comer of Landings and Landings Office Park P.U.D. October 27, 1995 Final Drainage Report Page 5 Specific Details. con't Boardwalk. From the inlet stormwater will be conveyed through an existing 15 inch RCP which daylights onto a vacant City of Fort Collins S.I.D. property at the southeast corner of the intersection. Stormwater will be conveyed from the pipe outlet to the Larimer #2 Canal via an open grass -lined swale. This channel will require a 10' drainage easement through the City of Fort Collins S.I.D. property. The size of the orifice controlling the release from Pond D1 has arbitrarily been set at 3-inch diameter which allows for a minimum release rate at a minimum practical diameter to minimize ' clogging. With stormwater being detained, undetained and discharged in three separate directions, summarizing a single release rate from the site is difficult. To summarize 100-yr flow rates in each direction, 2.3 cfs goes west to ShopKo to be ' detained, 3.67 cfs goes south to the off -site swale and 2.19 cfs goes north to High Pointe P.U.D.. It is important to note that the majority of the area contributing to undetained flows are the adjacent streets. Every attempt has been made to capture and detain stormwater from the site. Runoff from Basin D6 will be undetained and will collect at the existing 4' curb inlet located at the northwest corner of Landings and Boardwalk. From the inlet stormwater will be routed through the same conveyance elements as the release from Pond D1 to the Larimer #2 Canal. We attempted to direct this water to Pond D1 through the existing 4' curb inlet but due to the anticipated 100-year water surface elevation of 5042.38 in the pond, and the fact that the pond and street would then be ' hydraulically connected, water from the pond would back up into Landings Drive due to the existing flowline elevation of 5041.82 at the inlet. Detention Pond D4, located in the northeast corner of the site, will detain developed runoff from Basin D4 and will have a maximum release rate of 0.289 cfs through a 3" diameter control orifice. This parking lot detention pond will discharge into the flowline of Landings Drive, combine with flow from Basin D2 and continue north down Landings to an existing curb inlet and eventually into the Larimer County Canal #2. IV. EROSION CONTROL Temporary sediment control will be provided at the inlet end of both the detention pond outlets and silt fence will erected around the perimeter of the site. Permanent vegetative erosion control will be used in conjunction with landscaping in areas surrounding the building and parking areas and, in the parking i Landings Office Park P.U.D. October 27, 1995 Final Drainage Report Page 6 islands. The proposed grassed detention facility and off -site swale shall be covered with topsoil and revegetated with grass according to criteria given in Section 7 of the City of Fort Collins Erosion Control Reference Manual. Permanent Type L riprap will be provided at the outlet of the existing 15" RCP on the city's S.I.D. property and riprap will be placed at the outlets of all storm sewers. ' V. CONCLUSIONS Comoliance with Standards All drainage analyses have been performed according to the City of Fort Collins Storm Drainage Design Criteria Manual (SDDCM) and the Urban Drainage and Flood Control District's Drainage Criteria Manual. A variance is requested for the required 0.87 cfs/acre maximum release rate as stated in the "Final Drainage Report for Heart Special Improvement District". The total area of the site, out to the centerline of adjacent streets, is 4.079 acres which would translate into an allowable release rate of 0.87 cfs/acre x 4.079 acres = 3.55 cfs.. Since runoff from Basin D3 is detained through ShopKo, this leaves a total release rate of 3.67 + 2.19 cfs = 5.86 cfs from the remainder of the site. There will be some attenuation in the off -site swale and possibly Detention Pond "A" at High Pointe P.U.D.. The request for a variance is due to the inability to detain all developed runoff from the site due to topography. A variance is also requested for a maximum depth of parking lot detention of 1.66' in the northeast corner of Detention Pond D4. As requested by Stormwater Utility, signage has been required for this area, in addition the total area effected by this depth is a maximum of 2 parking stalls. The drainage certification for this project will be done building by building. Summary of Drainage Concept Measures have been taken to ensure adequate drainage facilities have been provided with attention given to water quality and, public health and safety of persons using the Landings Office Park facilities. The hydraulic and hydrologic analyses conducted for this study have been performed in a manner consistent with standard ' practice and principles of civil engineering. All known available information has been referenced where applicable to this study. Impacts to the Larimer County #2 Canal in relation to existing conditions shall be improved upon development of the site. Developed release rates are lower than historic at all discharge locations. I I I I 1 1 I 11 I Landings Office Park P.U.D. October 27, 1995 Final Drainage Report Page 7 REFERENCES 1. Storm Drainage Design Criteria and Construction Standards, City of Fort Collins, Colorado, May, 1984. 2. Final Drainage Report for Heart Special Improvement District, Engineering Professionals, Inc., December, 1984, Revised: January, 1985. 3. ShooKo P.U.D. Addendum to the Final Drainage Report, TST, Inc., August 10, 1993. 4. Final Drainage Report for High Pointe P.U.D., Parsons & Associates, Revised August 22, 1989. 5. Drainage Criteria Maunal, Urban Drainage and Flood Control District, Wright -McLaughlin Engineers, Denver, Colorado, March, 1969. Landings Office Park P.U.D. October 27, 1995 Final Drainage Report Page 8 APPENDIX PAGE Historic Drainage.......................................................................... 1 - 4 Developed Drainage................................................................... 5 - 17 Developed Detention.................................................................. 18- 30 Design of Inlets, Sewers and Culverts ....................................... 31- 40 Off -site Swale Design.................................................................. 41- 45 Erosion Control Calculations.............:......................................... 46- 53 Heart Special Improvement District Final Drainage Report.......... 54- 58 ShopKo P.U.D. Letter Addenum................................................... 59- 62 Final Drainage Report for High Pointe P.U.D ............................... 63- 65 Off -Site Drainage Easement Description ..................................... 66- 67 I I 1 1 1 1 HISTORIC DRAINAGE 1 I No Text HISTORIC DRAINAGE BOARDWALK COMMERCIAL, Fort Collins, Colorado File Number: HSTBSNH1.WOI BASIN H2: TOTAL AREA = A (ac) = 2.61 Area of Roofs (ac)= 0.1100 Area of Streets (ac)= 0.2300 Area of Gravel Parking (ac)= 0.200 Area of Lawn & Landscape(ac)= 1070 COMPOSITE RUNOFF COEFFICIENT: RUNOFF COEFFICIENTS: (From Table 3-3 Calcs Bv: MBW C for Roofs = 0.95 C for Asphalt = 0.95 C for Gravel = 0.50 C for Lawn = 0.25 C = 0.95(0.11+0.23ac)+ 0.50(.20ac)+ 0.25(2.07ac) = 0.36 2.61 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor: Storm Return Period of 100- Years) OVERLAND FLOW: (From North to South Across Site) Total Overland flow length = 257' T2 = 1.87 (1.1 , CCf) SQRT(L) = 16.4 min L (ft)= 257 CUBRT(S) S (%) = 97.3-97.56 = 3.79 17I00 = 1.87 (1.1 - CCf) SQRT(L) = 15.1 min 257 CUBRT(S) C = 015 GUTTER FLOW: (East down Boardwalk to Curb Inlet) L (ft)= 131 Tt = S (%) = 87.56 - 85.78 = 1.36 131 V(fps) = 2.30 (From Figure 3-2) 2-YEAR TIME OF CONCENTRATION; Tc2 = 16.4 + 0.9 17.3 min 100-YEAR TIME OF CONCENTRATION: Tc100 = 15.1 + 0.9 16.1 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.99 i100(in/hr)= 5.79 Q2(cfs) = CCf x i2 x A = 1.9 QI00(cfs) = CCf x i100 x A = 6.8 L = 0.9 min 60(V) I HISTORIC DRAINAGE BOARDWALK COMMERCIAL, Fort Collins, CO. File Number: HSTBSNH2.WQ1 13-Feb-95 Calcs Bv: MBW BASIN H2: TOTAL AREA = A (ac)= 1.18 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.0100 C for Roofs = 0.95 Area of Street (ac)= 0.1100 C for Streets = 0.95 Area of Lawn (ac)= 1.0600 C for Lawn = 0.25 Area of Gravel Parking (ac)= 0.000 C for Gravel = 0.50 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.01+ 0.11ac)+ 0.25(1.06ac) = 0.32 1.18 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: (From South to North; Off -site) Total Overland flow length = '163.00 T2 = 1.87 (1.1 - CCf) SQRT(L) = 11.0 min L (ft)= 163 CUBRT(S) S (%) = 95.3 - 85.0 = 6.32 , T100 = 1.87 (1.1 - CCf) SQRT(L) = 10.2 min 163 CUBRT(S) C = 0.25 2-YEAR TIME OF CONCENTRATION, Tc2= 11.0 min 100-YEAR TIME OF CONCENTRATION, Tc100= 10.2 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 2.40 i100(in/br)= 7.05 Q2(cfs) = CCf x i2 x A = 0.9 Q100(cfs) = CCf x i100 x A = 3.3 I northern enaineerina services, inc. I HISTORIC DRAINAGE BOARDWALK COMMERCIAL, Fort Collins, Colorado File Number: HSTBSNH3.WQI 24-A r-95 Calcs By: MBW BASIN H3: TOTAL AREA = A (ac)= 0.3 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.0000 C for Roofs = 0.95 Area of Streets (ac)= 01M C for Asphalt = 0.95 Area of Gravel Parking (ac)=- 0.000 C for Gravel = 0.50 Area of Lawn & Landscape(ac)= 0.096 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.204ac)+ 0.25(0.096ac) = 0.73 0.3 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: (From Northeast to Southwest Across Site) Total Overland flow length = 50' T2 = 1S7 (1.1 - CCf) SORT(L) = 4.8 min L (ft)= 50 CUBRT(S) S (%) = 98.0-91.65 = 12.70 T100 = 1.87 (1.1 - CCf) SQRT(L) = 45 min 50 CUBRT(S) C = 0.25 GUTTER FLOW: (South down JFK to Curb Inlet) L (ft)= 81 Tt = L = 0.5 min S (%) = 91.65 -89.74 = 2.36 60(V) 81 V(fps) = 3.00 (From Figure 3-2) 2-YEAR TIME OF CONCENTRATION; Tc2 = 4.8 + OS = 53 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 4.5 + 0.5 = 4.9 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 3.29 i100(in/hr)= 9.00 Q2(cfs) = CCf x i2 x A = 0.7 0100(cfs) = CCf x i100 x A = 2.5 I I 1 I I I i i I I DEVELOPED DRAINAGE I I DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DSNPNTDI.WQI 15-MaV-95 Calcs BV: MBW DESIGN POINT D1: (Includes Basin D1) TOTAL AREA = A (ac)= 0.8435 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.2738 C for Roofs = 0.95 Area of Concrete & Asphalt(ac)= 0.4708 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lavin (ac)= 0.0989 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.2738+.4708ac)+0.25(0.0989) = 0.87 0.8435 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: Total Overland flow length = 139' L (ft)= 139 S (%) = 54.5 - 48.25 = 139 C = 0.95 GUTTER FLOW: T2 = 1.87 (1.1 - CCf) SQRT(L) = 2.0 min CUBRT(S) 4.50 T100 = 1.87 (1.1 - CCf) SORT(L) = 1.3 min CUBRT(S) L (f )= 194 Tt = S (%) = 48.25 - 46.5 = 0.90 194 V(fps) = 1.90 (From Figure 3-2) 2-YEAR TIME OF CONCENTRATION; Tc2 = 2.0 + 1.7 = 3.7 min 100-YEAR TIME OF CONCENTRATION; TCI00 = 1.3 + 1.7 = 3.0 min RAINFALL INTENSITY: FROM FIGURE 3-1: Q2(cfs) = CCf x Q x A = Q1t10(cfs) = CCf x i100 x A = L 60M Use 5-min minimum Use 5-min minimum i2(in/hr)= 3.29 i100(in/hr)= 9.0 2.4 7.6 = 1.7 min 0 DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DSNPNTD2.WQI 15-May-95 Calcs BV: MBW DESIGN POINT D2: (Includes Basin 132) TOTAL AREA = A (ac)= 0.294 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.0000 C for Roofs = 0.95 Area of Concrete & Asphalt(ac)= 0.1560 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.1380 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.156ac)+0.25(0.138) = 0.62 0.294 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: Total Overland flow length = 50' T2 = 1.87 (1.1 - CCf) SQRT(L) = 5.6 min L (ft)= 50 CUBRT(S) S (%) = 47.0 - 42.87 = 8.26 T100 = 1.87 (1.1 - CCf) SORT(L) = 5.2 min 50 CUBRT(S) C = 0.25 GUTTER FLOW: (North Down Landings Drive to Propertyline) L (ft)= 132 Tt = L = 1.0 min S (%) = 42.87 - 41.0 = 1.42 60(V) 132 V(fps) = 2.30 (From Figure 3-2) 2-YEAR TIME OF CONCENTRATION; Tc2 = 6.5 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 6.1 min RAINFALL INTENSITY: ' FROM FIGURE 3-1: 02(cfs) = CCf x i2 x A = Q 100(cfs) = CCf x i I00 x A= i2(in/hr)= 2.95 000(in/hr)= 8.5 0.5 1.9 0 DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DSNPNTD3.WQ1 1 DESIGN POINT D3: (Includes Basin D3) TOTAL AREA = A (ac)= 0.336 RUNOFF COEFFICIENTS: (From Table Area of Roofs (ac)= 0.0000 C for Roofs = 0.95 Area of Concrete & Asphalt(ac)= 0.2130 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.1230 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.213ac)+0.25(0.123) = 0.69 0.336 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: Total Overland flow length = 65' L (ft)= 65 S (%) = 53.0 - 48.11 = 65 C = 0.25 GUTTER FLOW: (To Existing 15' Curb Inlet) Caics Bv: MBW T2 = 1.87 (1.1 - CCf) SQRT(L) = 6.5 min CUBRT(S) 7.52 T100 = 1.87 (1.1 - CCf) SORT(L) = 6.1 min CUBRT(S) L (ft)= 106 Tt = S (%) = 48.11 - 45.78 = 2.20 106 V(fps) = 2.90 (From Figure 3-2) 2-YEAR TIME OF CONCENTRATION; Tc2 = 6.5 + 0.6 = 7.2 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 6.1 + 0.6 = 6.7 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 2.86 i100(in/hr)= 8.0 i 1 Q2(cfs) = CCf x i2 x A = 0.7 Q100(cfs) = CCf x i100 x A = 2.3 L = 0.6 min 60(V) 0 DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DSNPNTD4.WQI 15-Mav-95 Calcs Bv: MBW DESIGN POINT D4: (Includes Basin 134) TOTAL AREA = A (ac)= 0.38 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.1080 C for Roofs = 0.95 Area of Concrete & Asphalt(ac)= 0.2170 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.0550 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.108+0.217ac)+0.25(0.055) = 0.85 0.38 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: (Across Paved Parking) Total Overland flow length = 119' L (ft)= 119 S (%) = 49.0 - 44.0 = 119 C = 0.95 72 = 1.87 (1.1 - CCf) SQRT(L) = 1.9 min CUBRT(S) 4.20 T100 = 1.87 (1.1 - CCf) SORT(L) = 1.3 min CUBRT(S) GUTTER FLOW: (To Parking Lot Detention Outlet) L (ft)= 67 Tt = L S (%) = 44.0 - 42.0 = 2.99 60(V) 67 V(fps) = 1.35 (From Figure 3-2) 2-YEAR TIME OF CONCENTRATION; Tc2 = 1.9 + 0.8 = 2.7 min (Use 5-minute minimum) 100-YEAR TIME OF CONCENTRATION; TC100 = 1.3 + 0.8 = 2.1 min (Use 5-minute minimum) RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 3.29 i100(in/hr)= 9.0 I 02(cfs) = CCf x i2 x A = 1.1 QI00(cfs) = CCf x i100 x A = 3.4 = 0.8 min 1 1 1 1 1 1 1 1 1 i 1 1 1 1 1 1 DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DSNPNTD5.WQ1 15-Mav-95 Calcs Bv: MBW DESIGN POINT D5: (Includes Basin D5) TOTAL AREA = A (ac)= 0.45 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.1720 C for Roofs = 0.95 Area of Concrete & Asphalt(ac)= 0.1610 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.1170 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.172+0.161ac)+0.25(0.117) = 0.77 0.45 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2 & 10 - Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: (Across Parking Lot) Total Overland flow length = 131' 1'2& T10 1.87 (1.1 - CCf) SQRT(L) = 2.0 min L (ft)= 131 CUBRT(S) S (%) = 54.0 - 48.84 = 3.94 T100 = 1.87 (1.1 - CCf) SQRT(L) = 1.4 min 131 CUBRT(S) C = 0.95 GUTTER FLOW: L (ft)= 19 S (%) = 48.84 - 48.54 = 19 V(fps) = 2.50 SWALE FLOW: (From L (ft)= 107 S (%) = 48.54 - 42.0 = 107 V(fps) = 3.70 2 & 10 -YEAR TIME OF CONCENTRATION; _ 100-YEAR TIME OF CONCENTRATION; T000 = RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= Q10(cfs) = CCf x i2 x A = 2.0 Q2(cfs) = CCf x i2 x A = 1.1 Q100(cfs) = CCf x i100 x A = 3.9 Tt = L = 0.1 1.58 60(V) (From Figure 3-2) Tt = L = 0.5 min 6.11 60(V) (From Figure 3-2) 2.6 min (Use 5-minute minimum) 2.0 min (Use 5-minute minimum) 3.29 i100(in/hr)= 9.0 i10(in/hr)= 5.7 O 71 DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DSNPNTD6.WQ1 15-May-95 Calcs Bv: MBW 't DESIGN POINT D6: (Includes Basin D6 11 TOTAL AREA = A (ac)= 0.500 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.0000 C for Roofs = 0.95 ' Area of Concrete & Asphalt(ac)= 0.3290 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.1710 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.329ac)+0.25(0.171) = 0.71 0.5 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: Total Overland flow length = 43' T2 = 1.87 (1.1 - CCf) SQRT(L) = 5.1 min L (ft)= 43 CUBRT(S) S (%) = 49.0 - 45.33 = 8.53 T100 = 1.87 (1.1 - CCf) SORT(L) = 4.7 min 43 CUBRT(S) C = 0.25 GUTTER FLOW: (To Existing 4' Curb Inlet) L (ft)= 462 Tt = L = 4.3 min S 45.33 - 41.82 = 0.76 60(V) 462 V(fps) = 1.80 (From Figure 3-2) 2-YEAR TIME OF CONCENTRATION; Tc2 = 9.4 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 9.0 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 2.57 i100(in/hr)= 7.5 Q2(cfs) = CCf x i2 x A = 0.9 Q100(cfs) = CCf x i100 x A = 3.3 a DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DSNPNTD7.WQ1 03-Apr-95 CaIcs Bv: MBW DESIGN POINT D7: (Includes Basin D7) TOTAL AREA = A (ac)= 0.185 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.0000 C for Roofs = 0.95 Area of Concrete & Asphalt(ac) 0.1310 C for Concrete = 0.95 Area of Gravel Parldng (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.0540 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.131ac)+0.25(0.054) = 0.75 0.185 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: Total Overland flow length = 13.5' T2 = 1.87 (1.1 - CCf) SQRT(L) = 4.6 min L (ft)= 13.5 CUBRT(S) S (%) = 54.57 - 54.3 = 2.00 T100 = 1.87 (1.1 - CCf) SQRT(L) = 4.3 min 13.5 CUBRT(S) C = 0.25 OVERLAND FLOW: Total Overland flow length = 104' T2 = 1.87 (1.1 - CCf) SQRT(L) = 1.7 min L (ft)= 104 CUBRT(S) S (%) = 54.3 - 49.3 = 4.81 T100 = 1.87 (1.1 - CCf) SQRT(L) = 1.1 min 104 CUBRT(S) C = 0.95 RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 3.00 i100(in/hr)= 9.00 Q2(cfs) = CCf x i2 x A 0.4 QI00(cfs) = CCf x i100 x A 1.6 DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DSNPNTD8.WQ1 DESIGN POINT D8: (Includes Basin D8) TOTAL AREA = A (ac)= 0.0518 Area of Roofs (ac)= 0.0000 Area of Concrete & Asphalt(ac)= 0.0518 Area of Gravel Parking (ac)= 0.0000 Area of Lawn (ac)= 0.0000 COMPOSITE RUNOFF COEFFICIENT: RUNOFF COEFFICIENTS: (From Table 3-3 15-Mav-95 Calcs Bv: MBW C for Roofs = 0.95 C for Concrete = 0.95 C for Gravel = 0.50 C for Lawn = 0.25 C = 0.95(0.0518ac) = 0.95 0.0518 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: Total Overland flow length = 80' L (ft)= 80 S (%) = 47.75 - 44.0 = 80 C = 0.95 2-YEAR TIME OF CONCENTRATION; Tc2 = 100-YEAR TIME OF CONCENTRATION; Tc100 = RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 3.3 Q2(cfs) = CCf x i2 x A = 0.2 QI00(cfs) = CCf x i100 x A = 0.5 T2 = 1.87 (1.1 - CCf) SQRT(L) = 1.5 min CUBRT(S) 4.69 T100 = 1.87 (1.1 - CCf) SQRT(L) = 1.0 min CUBRT(S) 1.5 min Use 5 min Tc 1.0 min Use 5 min Tc i100(in/hr)= 9.0 DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DEVBSND9.WQ1 15-May-95 CaIcs Bv: MBW DESIGN POINT D9: (Includes Basins' D1, D5, D7, D8 and D9) TOTAL AREA = A (ac)= 2.568 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.7430 C for Roofs = 0.95 Area of Concrete & Asphalt(ac)= 1.2000 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.6300 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT C = 0.95(0.743+1.20ac)+0.25(0.630) = 0.78 2.568 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) AT DESIGN POINT D5: Tc2= 2.6 min TC100= 2.0 min CULVERT FLOW: L (ft)= 164.24 S(%G)= 42.5-41.5= 164.24 Tt = 0.61 V(fps) = 2.26 (From HY8 Output) SWALE FLOW: L (ft)= 89 S(%)= 41.5-39.78= 89 1.93 Tt = L = 1.2 60M L = 0.7 min 60(V) V(fps) = 2.00 (From Figure 3-2) 2-YEAR TIME OF CONCENTRATION; Tc2 = 4.6 min (Use 5-minute minimum) 100-YEAR TIME OF CONCENTRATION; TOM = 4.0 min (Use 5-minute minimum) RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 3.29 Q2(cfs) = CCf x i2 x A = 6.6 QI00(cfs) = CCf x i100 x A = 22.5 i100(in/hr)= 9.0 14 DEVELOPED DRAINAGE LANDINGS OFFICE PARK P.U.D., Fort Collins, CO. File Number: DSNPTDIO.WQI 03-Apr-95 Calcs By: MBW DESIGN POINT D10: (Includes Basins' D2, D4 & Off -Site Basin) TOTAL AREA = A (ac)= 0.434 RUNOFF COEFFICIENTS: (From Table 3-3) Area of Roofs (ac)= 0.0000 C for Roofs = 0.95 Area of Concrete & Asphalt(ac) 0.2760 C for Concrete = 0.95 Area of Gravel Parldng (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.1580 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.276ac)+0.25(0.158) = 0.70 0.434 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: (From Design Point 132) Total Overland flow length = 50' T2 = 1.87 (1.1 - CCf) SQRT(L) = 5.6 min L (ft)= 50 CUBRT(S) S (%) = 47.0 - 42.87 = 8.26 T100 = 1.87 (1.1 - CCf) SQRT(L) = 5.2 min 50 CUBRT(S) C = 0.25 GUTTER FLOW: (North Down Landings Drive to Existing Curb Inlet) L (ft)= 299 Tt = S (%) = 42.87 - 37.3 = 1.86 299 V(fps) = 2.80 (From Figure 3-2) 2-YEAR TIME OF CONCENTRATION; Tc2 = 4.6 7.3 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 2.4 6.9 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 2.82 i100(in/hr) 7.5 Q2(cfs) = CCf x i2 x A 0.9 / Q100(cfs) = CCf x i100 x A 2.8 g-:5 L = 1.8 min 60(V) r C O N N tA O u: 0 1A 0 O IA lA JU O)0)to Qf ,,N NNf7 z O C C C C O O 0 6 0 Q Q cc Q a 0 U O C? W � U m ILL ~ O U LL Ix N Cr0T 0 N o W OR OI Q , • O \ .O O \ Q Z S: O c `°`°mm at0> �VMCL 0VAn Q Y >.m.. > m Q mNC0� '�QUa N Cl0 NLLQ(n Cf0 U; n U fn Q J J 11 imams insal u■ ME m■ DRAINAGE CRITERIA MANUAL r� RUNOFF 51 3( f- 2C 1 .5 �IIII MAIN M Noel RAM Il ,' , Milo •I .5- . 1 2 3 5 10 20 VELOCITY IN FEET PER SECOND FIGURE 3-2. ESTIMATE OF AVERAGE FLOW VELOCITY FOR `. USE WITH THE RATIONAL FORMULA. *MOST FREQUENTLY OCCURRING"UNDEVELOPED" LAND SURFACES IN THE DENVER REGION. REFERENCE: "Urban Hydrology For Small Watersheds':jechnlcaL,.._._, Release No. 55, USDA, SCS Jan. 1975. 5 -1-84 URBAN DRAINAGE & FLOOD CONTROL DISTRICT 11 DEVELOPED DETENTION I I I N 94 ZS i f 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Elevation v.s. Discharge Table for Detention Pond D1 Inout Parameters: Orifice Diameter = 3.0" (0.25') Area of Orifice (A) = 0.0491 fe Orifice Invert Elevation Orifice Centerline Elevation Coefficient of Discharge (Cd) Orifice Equation: Q = CdA = 5039.78 = 5039.91 = Varies with head (Table 4-3, Brater & King) ORIFICES, GATES, AND TUBES 4--29 R R pu S 3 S 3 n v0°i C is 0 0 0 0 0 0 0 6 6 0 0 0 0 I'2§5§ gases 198RR O Q 6 0 6 0 0'0 O 0 0 0 0 0 0 0 6 66 6 00000 00000 o N r r r rn l $�sg� ma�� u = mmmmm o 0 0 0 0 o c o 0 0 0 0 o c o o �. s I mmmm mmas� 8s$h y iz O O O O O O O O O O O O O O O O O Cf NN OHO~Ni 2O ♦p Oo 'D O O O O O O 00000 O O O O O O Epp u� �O O M b 2 S m m Epp pp t0 �D O O R • O 0 0 0 0 O O O O O O O O O O M b m N N V E QOOrr NNt+l r0 wocgs Y N n O Oa 6 N mh ON ONE ON h N R 7 R N N OOO OOOOO m aP PPPPm f000OO I N O M h h vi 9099P M �i N ui h O O O O 00006 00000 _ I S SO N R Rh_p_,O "N ou .N OOQO 06000 00000_ Is 0 N q '~ (pp pN {Oy 8 8 8 u O t 0 Ol D O 0 i7 O S O O V l H b O O O O O 0 0 0 0 0 00000 m 8c.2 IO 66666 0.6666 OOOO 1 Q I ee�� O ROO1p SS I OMH py tf §M" p O d O O O O O 000,601 O O O O O a — 0 v� E" : ISO `2.`2.mmm Z- 1,n O :6066 00000 00066 i rel I 1 1 Elevation v.s. Storage Table for Detention Pond D1 0 i O M Y V 11 y i m r L I 1 f�. I I ' i O i C G G o o O o 0 o C G o 0 v :i 0 0 o C G o 1 3 Q 3 i 3 i - i • Z i i s _ i mac' i 8��0��°.€RI"J8�'m,oR �'rl• Rh y i L i pap � Y I gg h 1 C F �p Q V i Y v N R. FZ IP.. g O a U • L `1 y (J . 1, 1.. ITi a'. 2 G d d C G d d d d OO C G •�I Ir. A� G OO C J i OO OO OO OO OO � 'S_'. S b • R z ' o= 1i n. c rri, n Ipi. Y t o e < w el l v =i =i I z S I i z e M ry 2 m N °] M O O o > O O 8 Q ••1 Q C `-' n r1 E � z_ $� e � .- ❑ c � c d d o o vl v ! Qom. Qt. C 5 ❑ ❑ m z - m i = 1 F" ----------------------------------------------- C UDINLET INLET HYDARULICS AND SIZING DEVELOPED BY DR. JAMES GUO, CIVIL ENG DEPT. U OF COLORADO AT DENVER �i SUPPORTED BY METRO DENVER CITIES/COUNTIES AND UD&FCD ---------------------------------I-------------------------------------------- SER:Northern Engineering Services -Ft Collins Colorado ....................... DATE 05-15-1995 AT TIME 11:46:10 *** PROJECT TITLE: LANDING P.U.D. *** CURB OPENING INLET HYDRAULICS AND SIZING: ' INLET ID NUMBER: 1 INLET HYDRAULICS: IN A SUMP. GIVEN INLET DESIGN INFORMATION: GIVEN CURB OPENING LENGTH (ft)= 4.00 HEIGHT OF CURB OPENING (in)= 6.00 INCLINED THROAT ANGLE (degree)= 63.43 LATERAL WIDTH OF DEPRESSION (ft)= SUMP DEPTH (ft)= 2_0 0.19 Note: The sump depth is additional depth to flow depth. STREET GEOMETRIES: STREET LONGITUDINAL SLOPE (%) = 2.00 STREET CROSS SLOPE (%) STREET MANNING N 2.00 0.016 GUTTER DEPRESSlON (inch)= 2.00 GUTTER WIDTH (ft) = 2.00 ISTREET FLOW HYDRAULICS: WATER SPREAD ON STREET (ft) = 11.97 GUTTER FLOW DEPTH (ft) = 0.41 FLOW VELOCITY ON STREET (fps)= 4.38 FLOW CROSS SECTION AREA (sq ft)= 1.60 GRATE CLOGGING FACTOR (%)= 50.00 CURB OPENNING CLOGGING FACTOR(%)= 20.00 INLET INTERCEPTION CAPACITY: IDEAL INTERCEPTION CAPACITY (cfs)= 8.12 BY FAA HEC-12 METHOD: DESIGN FLOW (cfs)= FLOW INTERCEPTED (cfs)= CARRY-OVER FLOW (cfs)= BY DENVER UDFCD METHOD: DESIGN FLOW (cfs)= FLOW INTERCEPTED (cfs)= CARRY-OVER FLOW (cfs)= IVl A Y. rit?.y7 = U . 1.9 , t- o . ¢ I + - O. �6 O + 7 .00 0.00 7.00 6.50 0.50 7J o S r� + Lc_ R�'1oS,j i +J %Z.:� S �z_^ o,�J 1 ow-..a—!� T►^= ��S i 1 1 1 1 i 1 1 1 1 1 1 1 1 1 1 1 1 1 nn b N N N N N N N N N N N NNNNN N s .$��� mmaaa aaaaaaa NNppN N NNp Npp NNN NNNmN Y pO O oNpp N W n 0 0 mN pN O O O O O O O O F h n i0 bG NN NpNip Npp NNNN NN 8 oNpNN O mm tNtppN mN t1a 00000 nnn nCOOM .a + e�ei ci cn av ci ei ei ei ei ci ci ri ci ei riri aoomone'i� `p MCp N N N N N N N N N N M M M M CNpN ! 000 a aNppp m0 tiaNq 8 b mOA i~-n NaNOM � Np NN N N NiN� N NMMMMMM 8 QN a00s� CNp pN AI�CppppYp O ONOUWw�n C N N N N N N N N N N N N M M M M M M mm n0 o`a a!nwnnn N M M M N M M M M M M � OnnaOp pNppp � ONNt�9M is nlN9 tN9nnn �+ N N N N N M M M Cl M M M M M M l �'l n n n O m V� O O O N N N N N N t� N n nmm��-1 NNN MOJ NNNNNNN O N N Nm M M M MMM M N M M M M M M � wiN+in e'innneNi oOe00e09 91 eNi eNi o er ein vi n ri nei ei ee rinnvin ni ri $'s N v b m o N+ O m 0 n o n O b o b o.l� ti I 1 1 1 1 1 f 1 t t 1 1 1 1 1 1 1 1 T 2 f a Elevation v.s. Discharge Table for Detention Pond D4 Inout Parameters: Orifice Diameter = 3.0" (0.25') Area of Orifice (A) = 0.0491 fe Orifice Invert Elevation = 5041.68 Orifice Centerline Elevation = 5041.81 Coefficient of Discharge (Cd) = Varies with head (Table 4-3, Brater & King) Orifice Equation: O = CdAV2gh Northern Engineering Services, Inc. I I I Elevation v.s. Storage Table for Detention Pond D4 u 11 I Li L I 3 o — � Q ec 3 3 8 8 8 8 0 o c c S I i ' I Y � r i 0 a � 8 8 8 8 8 8 8 8 n 8 8 8 8 z No Text I 0 1 1 1 i 1 1 11 1, DESIGN OF INLETS, SEWERS AND CULVERTS 11 1 --------------------------------------------------------------------------- �I UDINLET: INLET HYDARULICS AND SIZING DEVELOPED BY DR. JAMES GUO, CIVIL ENG DEPT. U OF COLORADO AT DENVER SUPPORTED BY METRO DENVER CITIES/COUNTIES AND UD&FCD ----------------------------------------------------------------------------- ER:Northern Engineering Services -Ft Collins Colorado ....................... DATE 04-26-1995 AT TIME 08:20:27 *** PROJECT TITLE: LANDINGS P.U.D. *** CURB OPENING INLET HYDRAULICS AND SIZING: INLET ID NUMBER: 1 �CHr�rS Ii�1Lr r71 ) INLET HYDRAULICS: IN A SUMP. GIVEN INLET DESIGN INFORMATION: GIVEN CURB OPENING LENGTH (ft)= 4.00 HEIGHT OF CURB OPENING (in)= 6.00 INCLINED THROAT ANGLE (degree)= 63.43 ' LATERAL WIDTH OF DEPRESSION (ft)= SUMP DEPTH (ft)= 2.00 0.14 _ Note: The sump depth is additional depth to flow depth. STREET GEOMETRIES: STREET LONGITUDINAL SLOPE (%) = 0.90 STREET CROSS SLOPE M 3.00 STREET MANNING N 0.016 GUTTER DEPRESSION (inch)= 2.00 _ GUTTER WIDTH (ft) = 2.00 STREET FLOW HYDRAULICS: WATER SPREAD ON STREET (ft) = 6.59 GUTTER FLOW DEPTH (ft) = 0.36 FLOW VELOCITY ON STREET (fps)= 2.92 ' FLOW CROSS SECTION AREA GRATE CLOGGING FACTOR (sq ft)= (%)_• 0.82 50.00 CURB OPENNING CLOGGING FACTOR(%)= 20.00 INLET INTERCEPTION CAPACITY: IDEAL INTERCEPTION CAPACITY (cfs)= 6.26 BY FAA HEC-12 METHOD: DESIGN FLOW (cfs)= FLOW INTERCEPTED (cfs)= CARRY-OVER FLOW (cfs)= BY DENVER UDFCD METHOD: DESIGN FLOW (cfs)= FLOW INTERCEPTED (cfs)= CARRY-OVER FLOW (cfs)= 2. 40 - C72_ E i_-).P. D 1 2.40 0.00 2.40 2.40 0.00 I --------------------------------------------------------------------- UDINLET: INLET HYDARULICS AND SIZING DEVELOPED BY DR. JAMES GUO, CIVIL ENG DEPT. U OF COLORADO AT DENVER SUPPORTED BY METRO DENVER CITIES/COUNTIES AND UD&FCD ------------------------------------------------------------------------------ ER:Northern Engineering Services -Ft Collins Colorado..: .................... DATE 05-15-1995 AT TIME 11:23:56 *** PROJECT TITLE: LANDINGS P.U.D. *** CURB OPENING INLET HYDRAULICS AND SIZING: INLET ID NUMBER: 1 ( INt_GT LD I ) INLET HYDRAULICS: IN A SUMP. GIVEN INLET DESIGN INFORMATION: GIVEN CURB OPENING LENGTH (ft)= 4.00 HEIGHT OF CURB OPENING (in)= 6.00 INCLINED THROAT ANGLE (degree)= 63.43 ' LATERAL WIDTH OF DEPRESSION (ft)= 2.00 SUMP DEPTH (ft)= 0.50 G^'s�=�- �� 4�•33 Note: The sump depth is additional depth to flow depth. STREET GEOMETRIES: STREET LONGITUDINAL SLOPE (%) = 0.90 STREET CROSS SLOPE (%) _ 3.00 STREET MANNING N 0.016 GUTTER DEPRESSION (inch)= 2.00 GUTTER WIDTH (ft) = 2.00 STREET FLOW HYDRAULICS: WATER SPREAD ON STREET (ft) = 11.41 ' GUTTER FLOW DEPTH (ft) = 0.51 FLOW VELOCITY ON STREET (fps)= 3.59 FLOW CROSS SECTION AREA GRATE CLOGGING FACTOR (sq ft)= (%)= 2.12 50.00 CURB OPENNING CLOGGING FACTOR(%)= 20.00 ' INLET INTERCEPTION CAPACITY: IDEAL INTERCEPTION CAPACITY (cfs)= 9.53 BY FAA HEC-12 METHOD: DESIGN FLOW (cfs)= 7.60 FLOW INTERCEPTED (cfs)= 7.60 ' CARRY-OVER FLOW (cfs)= 0.00 BY DENVER UDFCD METHOD: DESIGN FLOW (cfs)= 7.60 FLOW INTERCEPTED CARRY-OVER (cfs)= FLOW (cfs)= 7.60 0.00 I Culvert Rating Curve: Storm Sewer Line D5 CURRENT DATE: 05-15-1995 CURRENT TIME: 11:28:53 FRWA CULVERT ANALYSIS HY-8, VERSION 4.1 FILE DATE: 02-15-1995 FILE NAME: BWC C U SITE DATA CULVERT SHAPE, MATERIAL, INLET L INLET OUTLET CULVERT BARRELS V ELEV. ELEV. LENGTH SHAPE SPAN RISE MANNING INLET (FT) (FT) (FT) MATERIAL (FT) (FT) n TYPE 1 5042.50 5041.50 164.24 1 ADS N-12 1.50 1.50 .010 IMPR SDT CIR 1 3 4 5 6 SUMMARY OF CULVERT FLOWS (CFS) FILE: BWC DATE: 02-15-1995 ELEV (FT) TOTAL 1 2 3 4 5 6 ROADWAY ITR 5042.50 0 0 0 0 0 0 0 O 1 5042.99 1 1 0 0 0 0 0 0 1 5043.21 2 2 0 0 0 0 0 0 1 5043.31 3 3 0 0 0 0 0 0 1 5043.48 4 4 0 0 0 0 0 0 1 5043.63 5 5 0 0 0 0 0 0 1 5043.78 6 6 0 0 0 0 0 0 1 5043.94 1 1 0 0 0 0 0 0 1 5044.08 8 8 0 0 0 0 0 0 1 5044.23 9 9 0 0 0 0 0 0 1 5044.38 10 10 0 0 0 0 0 0 1 5044.68 11 11 0 0 0 0 0 OVERTOPPING I O 1 2 1 CURRENT DATE: 05-15-1995 FILE DATE: 02-15-1995 CURRENT TIME: 11:28:53 FILE NAME: BWC 1 PERFORMANCE CURVE FOR CULVERT i 1 - I ( 1.5 BY 1.5 ) RCP DIS- HEAD- INLET OUTLET 1 CHARGE WATER CONTROL CONTROL FLOW NORMAL CRITICAL OUTLET TAILWATER FLOW ELEV. DEPTH DEPTH TYPE DEPTH DEPTH VEL. DEPTH VEL. DEPTH (cfs) (ft) (ft) (ft) <F4> (ft) (ft) (fps) (ft) (fps) (ft) 1 1 1 1 n 0 1 1 0 5042.50 0.00 0.00 0-NF 0.00 0.00 0.00 0.00 0.00 0.88 1 5042.99 0.49 0.49 I-S2n 0.31 0.37 3.80 0.31 0.00 0.88 2 5043.21 0.71 0.71 1-S2u 0.44 0.53 4.58 0.44 0.00 0.88 3 5043.31 0.81 0.81 1-S2u 0.51 0.61 4.96 0.51 0.00 0.88 4 5043.48 0.98 0.98 1-S2u 0.64 0.76 5.57 0.64 0.00 0.88 5 5043.63 1.13 1.13 1-Stu 0.73 0.86 5.87 0.73 0.00 0.88 6 5043.78 1.28 1.28 i-S1n 0.81 0.94 6.14 0.81 0.00 0.88 7 5043.94 1.44 1.44 1-S2n 0.90 1.02 6.36 0.90 0.00 0.88 8 5044.08 1.58 1.58 5-S2u 0.98 1.09 6.54 0.98 0.00 0.88 9 5044.23 1.73 1.73 5-S2u 1.07 1.16 6.66 1.07 0.00 0.88 10 5044.38 1.88 1.88 5-S2u 1.17 1.22 6.75 1.17 0.00 0.88 El. inlet face invert 5042.50 ft E1. outlet invert $041.50 ft E1. inlet throat invert 5042.47 ft El. inlet crest 0.00 ft *$$** SITE DATA xx>== CULVERT INVERT s:tsst:sss M INLET STATION (FT) 0.00 INLET ELEVATION (FT) 5042.50 OUTLET STATION (FT) 169.90 OUTLET ELEVATION (FT) 5041.50 NUMBER OF BARRELS 1 SLOPE (V-FT/H-FT) 0.0059 CULVERT LENGTH ALONG SLOPE (FT) 164.24 f==== CULVERT DATA SUMMARY ==3==ssssssssssssust::: BARREL SHAPE CIRCULAR BARREL DIAMETER 1.50 FT BARREL MATERIAL ADS H-12 POLYETHYLENE BARREL MANNING'S N 0.010 INLET TYPE IMPR SOT CIRC INLET EDGE AND WALL SQUARE EDGE TOP (26-90 DEG WINGWALL) INLET DEPRESSION MORE SIDE -TAPERED CIRCULAR IMPROVED INLET tsttttt FACE WIDTH 4.33 FT SIDE TAPER (4:1 TO 6:1) (E:1) 4.00 FACE HEIGHT 1.50 FT 1 3 CURRENT DATE: 05-15-1995 FILE DATE: 02-15-1995 CURRENT TIME: 11:28:53 FILE NAME: BNC TAILWATER CONSTANT WATER SURFACE ELEVATION (Pond DI 100-Yr WSEL) 5042.38 ROADWAY OVERTOPPING DATA ROADWAY SURFACE PAVED EMBANKMENT TOP WIDTH (FT) 30.00 t==== USER DEFINED ROADWAY PROFILE CROSS-SECTION K Y COORD. NO. (FT) (FT) 1 0.00 5044.68 2 16.76 5045.92 3 32.00 5045.52 11 0 STORM SEWER SYSTEM DESIGN USING UDSEWER YODEL Developed by Dr. James Goo, Civil Eng. Dept, U. of Colorado at Denver Metro Denver Cities/Counties A UDFCD Pool Fund Study DSER:NORTHERN ENG SERVICES INC-FT COLLINS COLORADO ........................... ON DATA 04-26-1995 AT TIME 12:05:36 VERSION=03-26-1994 PROJECT TITLE :Landings P.D.D.; Storm Sewer Line D7 ' jt= RETURN PERIOD OF FLOOD IS 100 YEARS ' RAINFALL INTENSITY FORMULA IS GIVEN Ot SUMMARY OF SUBBASIN RUNOFF PREDICTIONS ' ------------ ---- - - ------- TIME OF CONCENTRATION -------------- -------- MANHOLE BASIN OVERLAND GUTTER BASIN RAIN I PEAK FLOW ' ID NUMBER AREA = C To (MIN) Tf (MIN) Tc (MIN) IRCH/HR ---------------------------------------------------------------------- CFS 1.00 0.00 0.00 0.00 0.00 0.00 0.00 2.00 0.00 0.00 0.00 0.00 4.58 3.00 0.14 0.00 0.00 5.00 11.53 0.00 1.60 ' THE SHORTEST DESIGN RAINFALL DURATION IS FIVE MINUTES DENVER CRITERIA WAS NOT USED TO CHECK THE COMPUTATED Tc. i== SUMMARY OF HYDRAULICS AT MANHOLES ------------------------------------------------------------------------------- MANHOLE CNTRBTING RAINFALL RAINFALL DESIGN GROUND WATER COMMENTS ID NUMBER AREA i C DURATION INTENSITY PEAK FLOW ELEVATION MINUTES INCH/HR CFS FEET ELEVATION FEET - --- -------------- --------------------------------------- 1.00 0.00 0.00 0.00 0.00 5047.50 5047.13 OK 2.00 0.14 5.00 11.53 1.60 5048.45 5047.22 OK 3.00 0.14 5.00 11.53 1.60 5049.50 5048.03 OK OK MEANS WATER ELEVATION IS LOWER THAN GROUND ELEVATION SUMMARY OF SEWER HYDRAULICS NOTE: THE GIVEN FLOW DEPTH -TO -SEWER SIZE RATIO= .8 SEWER MANHOLE NUMBER SEWER REQUIRED SUGGESTED EXISTING ID NUMBER UPSTREAM DNSTREAM SHAPE DIA(RISE) DIA(RISE) DIA(RISE) WIDTH ID NO. ID NO. (1N) (FT) (1N) (FT) (IN) (FT) (FT) ---------- - ----------------------------------------------------------- 1.00 1.00 1.00 ROUND 10.45 15.00 12.00 0.00 2.00 3.00 2.00 ROUND 8.57 15.00 DIVERSION UNITS FOR ROUND AND ARCH SEWER ARE IN INCHES 12.00 0.00 DIMENSION UNITS FOR BOX SEWER ARE IN FEET ' r ' REQUIRED DIAMETER WAS DETERMINED BY SEWER HYDRAULIC CAPACITY. S➢GGESTED DIAMETER WAS DETERMINED BY COMMERCIALLY AVAILABLE SIZE. FOR A NEW SEWER, FLOW WAS ANALYZED BY THE SUGGESTED SEWER SIZE; OTHERWISE, EKISITNG SIZE WAS USED SEWER DESIGN FLOW NORMAL NORAAL CRITIC CRITIC FULL FROUDE COMMENT ID FLOW Q FULL Q DEPTH VLCITY DEPTH VLCITY VLCITY NO. NUMBER CFS CFS FEET FPS FEET FPS FPS ---------------------------------------------------------------------- 1.0 1.6 2.3 0.61 3.19 0.54 3.70 2.04 0.78 V-OK 2.0 1.6 3.9 0.44 4.76 0.54 3.70 2.04 1.44 V-OK ' FROUDE NUMBER=0 INDICATES THAT A PRESS➢RED FLOW OCCDRS ---------------------------------------------------------------------- SEWER SLOPE INVERT ELEVATION BURIED DEPTH COMMENTS ' ID NUMBER UPSTREAM DNSTREAM UPSTREAM DNSTREAM 3 (FT) (FT) (FT) (FT) ' ----------------------------------------------------------- 1.00 0.25 5046.44 5046.13 1.01 0.37 OE 2.00 0.72 5047.49 5046.44 1.01 1.01 OK OE MEANS BURIED DEPTH IS GREATER THAN REQUIRED SOIL COVER OF 1 FEET M SUMMARY OF HYDRAULIC GRADIENT LINE ALONG SEWERS ----------------------------------------------------------------------- SEWER SEWER SURCHARGED CROWN ELEVATION WATER ELEVATION FLOW ID NUMBER LENGTH LENGTH UPSTREAM DNSTREAM UPSTREAM DNSTREAM CONDITION ' ------ FEET FEET -------------------------------=---------------------------- FEET FEET FEET FEET 1.00 125.38 0.00 5047.44 5047.13 5047.22 5047.13 SUBCR ' 2.00 146.21 0.00 5048.49 5047.44 5048.03 5047.22 JUMP PRSS'ED=PRESSDRED FLOW; JUMP=POSSIBLE HYDRAULIC JUMP; SUBCR=SUBCRITICAL FLOW SUMMARY OF ENERGY GRADIENT LINE ALONG SEWERS ------------------------------------------------------------------------------- UPST MANHOLE SEWER JUNCTURE LOSSES DOWNST MANHOLE SEWER MANHOLE ENERGY FRCTION BEND BEND LATERAL LATERAL MANHOLE ENERGY ID NO ID NO. ELEV FT FT K COEF LOSS FT K COEF LOSS FT ID FT ------- -------- -------- -------- 1.0 2.00 5047.31 0.18 0.05 ----- --------------------------- 0.00 0.00 0.00 1.00 5047.13 2.0 3.00 5048.24 0.84 1.32 0.09 0.00 0.00 2.00 5047.31 BEND LOSS =BEND K+ FLOWING FULL VHEA.D IN SEWER. LATERAL LOSS= OUTFLOW FULL VHEAD-JCT LOSS K=INFLOW FULL VHEAD FRICTION LOSS4 MEANS IT IS NEGLIGIBLE OR POSSIBLE ERROR DUE TO JUMP. ' FRICTION LOSS INCLUDES SEWER INVERT DROP AT MANHOLE NOTICE: VREAD DENOTES THE VELOCITY HEAD OF FULL FLOW CONDITION. A MINIMUM JUCTION LOSS OF 0.05 FT WORLD BE INTRODUCED UNLESS LATERAL K=O. ' FRICTION LOSS WAS ESTIMATED BY BACKWATER CURVE COMPUTATIONS, ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ STORY SEWER SYSTEM DESIGN USING UDSEWER YODEL Developed by Dr. Jaies Gun, Civil Eng. Dept, U. of Colorado at Denver Metro Denver Cities/Counties A UDFCD Pool Fund Study ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ USER:NORTHERN EKG SERVICES INC-FT COLLINS COLORADO ........................... ON DATA 05-17-1995 AT TIME 06:59:38 VERSION43-26-1994 PROJECT TITLE :Landings P.U.D.: Storm Sewer Line D8 ff= RETURN PERIOD OF FLOOD IS 100 YEARS RAINFALL INTENSITY FORMULA IS GIVEN Ot SUMMARY OF SUBBASIN RUNOFF PREDICTIONS TIME OF CONCENTRATION MANHOLE BASIN OVERLAND GUTTER BASIN RAIN I PEAK FLOW .1D NUMBER AREA = C To (MIN) Tf (MIN) Tc (MIN) INCH/HR CFS ---------------------------------------------------------------------- 1.00 0.05 0.00 0.00 0.00 4.58 0.23 2.00 0.05 0.00 0.00 0.00 4.58 0.23 3.00 0.05 0.00 0.00 0.00 4.58 0.23 4.00 0.05 0.00 0.00 5.00 10.16 0.50 THE SHORTEST DESIGN RAINFALL DURATION 1S FIVE MINUTES DENVER CRITERIA WAS NOT USED TO CHECK THE COMPUTATED Tc. __= SUMMARY OF HYDRAULICS AT MANHOLES MANHOLE CRTRBTING RAINFALL RAINFALL DESIGN GROUND WATER COMMENTS ID NUMBER AREA 3 C DURATION INTENSITY PEAK FLOW ELEVATION ELEVATION MINUTES INCH/HR, CFS FEET FEET 1.00 0.00 0.00 0.00 0.50 5044.00 5042.33 OE 2.00 0.15 12.02 3.39 0.50 5045.80 5042.34 OE 3.00 0.10 5.00 5.08 0.50 5045.40 5043.18 OE 4.00 0.05 5.00 10.16 0.50 5044.50 5043.35 OE OK MEANS WATER ELEVATION IS LOWER THAN GROUND ELEVATION 6 SUMMARY OF SEWER HYDRAULICS NOTE: THE GIVEN FLOW DEPTH -TO -SEWER SIZE RATIO= .8 ------------------------------------------------------------------------------- SEWER MANHOLE NUMBER SEWER REQUIRED SUGGESTED EXISTING 1D NUMBER UPSTREAM DNSTREAM SHAPE DIA(RISE) DIA(RISE) DIA(RISE) WIDTH -------- ID NO. ID N0. (IN) (FT) (IN) (FT) (IN) (FT) (FT) -- - ---------------------------------------------------------- 1.00 2.00 1.00 ROUND 5.37 6.00 6.00 0.00 2.00 3.00 2.00 ROUND 5.37 6.00 6.00 0.00 3.00 4.00 3.00 ROUND 5.37 6.00 6.00 0.00 DIMENSION UNITS FOR ROUND AND ARCH SEWER ARE IN INCHES DIMENSION UNITS FOR BOX SEWER ARE IN FEET REQUIRED DIAMETER WAS DETERMINED BY SEWER HYDRAULIC CAPACITY. SUGGESTED DIAMETER WAS DETERMINED BY COMMERCIALLY AVAILABLE SIZE. FOR A NEW SEWER, FLOW WAS ANALYZED BY THE SUGGESTED SEWER SIZE; OTHERWISE, EXISITNG SIZE WAS USED SEWER DESIGN FLOW NORMAL BORAML CRITIC CRITIC FULL FROUDE COMMENT ID FLOW Q FULL Q DEPTH VLCITY DEPTH VLCITY VLCITY NO. NUMBER CFS CPS FEET FPS FEET FPS FPS ------------------------------------------------------------------------------- 1.0 0.5 0.7 0.32 3.76 0.35 3.36 2.55 1.26 V-OK 2.0 0.5 0.7 0.32 3.76 0.35 3.36 2.55 1.26 V-OK 3.0 0.5 0.7 0.32 3.76 0.35 3.36 2.55 1.26 V-OK FROUDE NUMBER=O INDICATES THAT A PRESSURED FLOW OCCURS SEWER SLOPE INVERT ELEVATION BURIED DEPTH COMMENTS ID NUMBER UPSTREAM DNSTREAM UPSTREAM DNSTREAM 3 (FT) (FT) (FT) (FT) ---------------------------------------------------------------------- 1.00 0.85 5041.99 5041.83 3.31 1.67 OE 2.00 0.85 5042.83 5041.99 2.07 3.31 OE 3.00 0.85 5043.00 5042.83 1.00 2.07 OK OE MEANS BURIED DEPTH IS GREATER THAN REQUIRED SOIL COVER OF 1 FEET ttt SUMMARY OF HYDRAULIC GRADIENT LIKE ALONG SEWERS SEWER SEWER SDRCHARGED CROWN ELEVATION WATER ELEVATION FLOW ID NUMBER LENGTH LENGTH UPSTREAM DNSTREAM UPSTREAM DNSTREAM CONDITION FEET FEET FEET FEET FEET FEET ------------------------------------------------------------------------------- 1.00 18.30 0.00 5042.49 5042.33 5042.34 5042.33 JUMP 2.00 99.21 0.00 5043.33 5042.49 5043.18 942.34 JUMP 3.00 20.07 0.00 5043.50 5043.33 5043.35 5043.18 JUMP PRSS'ED=PRESSDRED FLOW; JUMP=POSSIBLE HYDRAULIC JUMP; SOBCR=SDBCRITICAL FLOW I 0 ' M SUMMARY OF ENERGY GRADIENT LINE ALONG SEVERS ' UPST MANHOLE SEWER JUNCTURE LOSSES DOWNST MANHOLE SEWER MANHOLE ENERGY FRCTION BEND BEND LATERAL LATERAL MANHOLE ENERGY NO ID NO. ELEV FT FT K COEF LOSS FT E COEF LOSS FT ID FT -ID - ---- -------- -------- -------- -------- ---------------------------------- 1.0 2.00 5042.52 0.19 0.05 0.00 0.00 0.00 1.00 5042.33 2.0 3.00 5043.36 0.83 0.08 0.01 0.00 0.00 2.00 5042.52 ' 3.0 4.00 5043.53 0.16 0.08 0.01 0.00 0.00 3.00 5043.36 BEND LOSS =BEND K= FLOWING FULL VHEAD IN SEWER. LATERAL LOSS= OUTFLOW FULL VBEAD-JCT LOSS K=INFLOW FULL VHEAD ' FRICTION LOSS=O MEANS IT IS NEGLIGIBLE OR POSSIBLE ERROR DOE TO JUMP. FRICTION LOSS INCLUDES SEWER INVERT DROP AT MANHOLE NOTICE: VBEAD DENOTES THE VELOCITY BEAD OF FULL FLOW CONDITION. A MINIMUM JUCTION LOSS OF 0.05 FT WORLD BE INTRODUCED UNLESS LATERAL K=O. FRICTION LOSS WAS ESTIMATED BY BACKWATER CURVE COMPUTATIONS. SUMMARY OF EARTH EXCAVATION VOLUME FOR COST ESTIMATE. THE TRENCH SIDE SLOPE = 1 --------------------------------------------------------------------- MANHOLE GROUND INVERT MANHOLE ID NUMBER ELEVATION ELEVATION HEIGHT FT -----------------F-------------------F----------------------------------------- 1.00 5044.00 5041.83 1.17 2.00 5045.80 5041.99 3.81 3.00 5045.40 5042.83 2.57 4.00 5044.50 5043.00 1.50 ------------------------------------------------------------------------------- SEWER UPST TRENCH WIDTH DNST TRENCH WIDTH TRENCH WALL EARTH ID NUMBER ON GROUND AT INVERT ON GROUND AT INVERT LENGTH THICKNESS VOLUME FT FT FT FT FT INCHES ------------------------------------------------------------------------------- CUBIC YD 1.00 8.87 2.75 5.58 2.75 18.30 1.50 11.3 ' 2.00 6.39 2.75 8.88 2.75 99.21 1.50 65.7 3.00 4.25 2.75 6.39 2.75 20.07 1.50 7.6 TOTAL EARTH VOLUME FOR SEWER TRENCHES = 84.60274 CUBIC YARDS EARTH VOLUME WAS ESTIMATED TO HAVE BOTTOM WIDTH=DIAMETER OR WIDTH OF SEWER + 2 = B B=ONE FEET WHEN DIAMETER OR WIDTH <=48 INCHES B=TWO FEET WHEN DIAMETER OR WIDTH >48 INCHES IF BOTTOM. WIDTH <MINIMUM WIDTH, 2 FT, THE MINIMUM WIDTH WAS USED. BACKFILL DEPTH UNDER SEWER WAS ASSUMED TO BE ONE FOOT ' SEWER WALL THICKNESS=EQIVLNT DIAMATER 1N INCH/12 +1 IN INCHES 1 OFF -SITE SWALE DESIGN Northern Engineering CLIENT JOB NO. Services, Inc. PROJECT CALCULATIONS FOR Fort Collins. Colorado 80521 MADE BY M-24oy DATE CHECKED BY DATE� SHEET_ OF I Triangular Channel Analysis & Design Open Channel - Uniform flow Worksheet Name: Landings P.U.D. Comment: Capacity of Off -site Swale Solve For Depth Given Input Data: Left Side Slope.. 4.00:1 (H:V) Right Side Slope. 4.00:1 (H:V) Manning's n...... 0.030 Channel Slope.... 0.0068 ft/ft Discharge........ 9.40 cfs Computed Results: Depth............ Velocity......... Flow Area........ Flow Top Width... Wetted Perimeter. Critical Depth... Critical Slope... Froude Number.... 0.97 ft 2.48 f p s v S� �✓i , r. _-- _ 3.79 sf 7.79 ft 8.03 ft 0.81 ft 0.0185 ft/ft 0.63 (flow is Subcritical) Open Channel Flow Module, Version 3.42 (c) 1991. Haestad Methods, Inc. * 37 Brookside Rd * Waterbury, Ct 06708 I 11 Triangular Channel Analysis & Design Open Channel - Uniform flow Worksheet Name: Landings P.U.D. Comment: 100-Yr Velocity Check of Off -site Swale Solve For Depth Given Input Data: Left Side Slope.. Right Side Slope. Manning's n...... Channel Slope.... Discharge........ Computed Results: Depth............ Velocity......... Flow Area........ Flow Top Width... Wetted Perimeter. Critical Depth... Critical Slope... Froude Number.... 4.00:1 (H:V) 4.00:1 (H:V) 0.030 0.0190 ft/ft 7.00 cfs 0.72 ft 3.38 fps 2.07 sf 5.75 ft 5.93 ft 0.72 ft 0.0192 ft/ft 0.99 (flow is Subcritical) Open Channel Flow Module, Version 3.42 (c) 1991 Haestad Methods, Inc. * 37 Brookside Rd * Waterbury, Ct 06708 i Q1 -r 4- Y 4- O Q N O O Co Ln to LA Ln L i M m M C7 Cl) cn 4� C7 M O O O O O O m v ; C O O O O O O O O ro L LL 4- 4- 4- ir O 4- C O 11) U7 O O O O O Cl 4L 3 •"� O O O O N V) Cl O 1 to 41 F- N r r` N O O O O O O N Z O LL ro i. W O i Y U N L • O LL L- '7 LL CO 1 W i N O > N W U d .J V) 7 7 m Lu i Q W a t F- Y (A = 7 Q-1 in U/ N r0 Ln N L L L L N C7 i 4J N U U U U •r- z rn L L c C c C 3 �--� U U •r- •r •r •r Z O C C N Z •r• •r (V �r (V R .— Q ro N .--1 N N .--1 N Gl 4- N lD N N C 4- 1 M 4- 4- r6 4- 4- C 7 O i O O i O O r'J Y t L L L V 4- 4- T 4- Y c Ln 3 rCp c c rCp c c s i E J � J J � J J •� cm C C r0 (a f0 L 0 4� v rp• -0 N r0 N rr3 m N E i L i O O co C 7 LL- {I Qy� 7 �i 6I U I 1 I 0 I I I 1 EROSION CONTROL CALCULATIONS I I S. RAINFALL PERFORMANCE STANDARD EVALUATION PROJECT: Landings Office Park P.U.D. STANDARD FORM A COMPLETED BY: Mary B. Wohnrade DATE: June 20, 1995 Developed Erodibility Asb Lab Ssb Lb Sb PS(Table 8-A) Sub -Basin Zone (ac) (ft) (%) (ft) (%) (%) D1 Moderate 0.844 333 2.40 D5 0.450 257 4.67 D7 0.185 118 4.49 D8 0.052 80 4.69 D9 1.038 465 3.18 Total = 2.568 308 3.31 82.2 D4 Moderate 0.380 186 3.76 82.2 D2 Moderate 0.294 50 8.26 83.7 D3 Moderate 0.336 65 7.52 83.5 D6 Moderate 0.500 43 8.53 83.7 Lb = sum (Lsb x Asb) / sum Asb Sb = sum (Ssb x Asb) / sum Asb Performance Standard (PS) = See Table 5.1 CAW P5\DRAT NAGE\STNDFRMB. ERS 1 1 1 1 1 1 i 1 1 1 1 t 1 1 t 1 1 1 CONSTRUCTION SEQUENCE SEQUENCE FOR 1995— 96 COMPLETED BY: MBW DATE: SEPT 15, 1995 1995— 96 MONTH UG EP T OV DEC JAN FEB M PR MAY JUNJJLY OVERLOT GRADING: ha es' I & II WIND EROSION CONTROL' Soil Roughening Perimeter Barger Additional Barriers VS5eeqgetsoetavlee Methods WOtheont RAINFALL EROSION CONTROL STRUCTURAL: Sediment Trap/Basin Inlet Filters Straw Barriers , Silt Fence. Barriers Ph ses' 1 11 Band q s Bore oilg Preparation Contour Furrows Terracin Aspholt�oncrete Paving RipRop Outlet Control pas I Pas II VEGETATIVE: Permanent Seed Pic tin Mulching%Sealant Temporary Seed Planting Sod Ins allatr n has I Ph ses' 18 II P ose I Iasi! Netting�Mats%Blankets Other STRUCTURES: INSTALLED BY MAINTAINED BY VEGETATION/MULCHING CONTRACTOR DATE SUBMITTED: 05/22/95 APPROVED BY CITY OF FORT COLLINS ON I I I I I I EFFECTIVENESS CALCULATIONS PROJECT: Landings Office Park P.U.D. STANDARD FORM B COMPLETED BY: Mary B. Wohnrade DATE: June 20, 1995 Erosion Control Method C-Factor P-Factor_ Comment Roads/Walks 0.01 1.00 All Basins Hay Mulch 0.06 1.00 All Basins Gravel Filter 1.00 0.80 Basin D4 Straw Bale Barriers 1.00 0.80 Basins' D5, D9 Established Grass 0.03 1.00 Pond D1 Silt Fence 1.00 0.50 Basins' D2, D3, D6 Sod Grass 0.01 1.00 All Basins Major Performance Sub -Basin Area Calculations Basin Standard (%) (Ac) D1, D5 82.2 2.568 Roads/Walks = 1.20 ac D7, D8, D9 Sod Grass = 0.409 ac Hay Mulch = 0.738 ac Established Grass = 0.221 Net C Factor = 1.20(0.01)+ 0.409(0.01)+0.738(0.06) +0.221(0.03)/2.568 = 0.067 Net P Factor = 0.80 EFF = (1-(0.067 x 0.80))/100= 94.6% D4 82.2 0.380 Roads/Walks = 0.217 ac Sod Grass = 0.055 ac Hay Mulch = 0.108 ac Net C Factor = 0.217(0.01)+0.055(0.01) +0.108(0.06)/0.380 = 0.0242 Net P Factor = 0.80 EFF = (1-(0.0242 x 0.80))/100=98.1% D2 83.7 0.294 Roads/Walks = 0.156 ac Sod Grass = 0.138 ac Net C Factor = 0.156(0.01)+0.138(0.01) /0.294 = 0.01 Net P Factor = 0.50 EFF = (1-(0.01 x o.50))/100=99.5% BASINS' D3 AND D6 WILL ALSO HAVE AN EFF= 99.5% CAW P5\DRAINAGE\STNDFRMB. ERS I o o+ 01 0 0 o O o aa In to In In IOD OD 00 00 0 I I I O z aH ra U a W I a ON z H L -MARCH 1991 0 rn000000000 . . . . . . . . . . . O �d'�d'�����u1 lw aoWWWWWWWWW 0 0ornolrnrno,o,olo,otrnrn000 . . . . . . . . . . . . . . . . o v�vvv.rcvvvvaininin o r . . CO W a0 01 01 0� 01 01 O1 01 01 01 01 01 O. 01 01 01 0+ . . . N W W W W W W W W W W W W W W W W W W W W 0 oMaIntototo�nnrrrrrrnrrnrW W W W W W . . . . . . . . . . . . . . . . . . . . . . . . . . . WWCID CID WWWCID WWWWWODWWWWWWWWWWWW o ODNMV LOthInWkotDw pWrrrnhrnrnr000000 0. Md d ;d d V V ;d d ; V ;4444ed V erd Td V W W W W W W W W W W CO W CO CO W W W W W W CO W W W W W o %00NMvvulln10InW%0%0tO%D%0%0w%0 ornrnrn . . . . . . . . . . . . . . . . . . . . . W W W W W W CO W W W W W W W ao 0o OD CO ao W W W W W W W O C 01 r1 N M N1 V' i i i In <n In In In It1 In In In tD tD % tD tD to r OD OD W W CO W CD CD W W CO W 00 OD OD W OD OD W W W W OD W 00 W O Ot0OD0-4r4NNMMMMafer-w-vvvvvIntntn��� . . . . . . . . . . . . . . . . . . . . . . . . t0 MMMvvtPv44d'er-'sPd'V'e}d'd'd''eYd' 00 W 00 CD CO W W 00 W OD W CD W W W W W CO CO OD OD CO W W 00 W �O InNlnr W O%00rlrlrlNNNNNMMMMMsrd ��}� dP . . . . . . . . . . . . . . . . . . . W W OD W W CD OD CO W W W W O0 CD OD OD CD OD CD OD 00 W OD OD 00 W CO W In H co H(n wInIn%0%DnnnW CO W CD OD OD0%O1ON00000 sN N M M M M M M M. M M M. M M M M M M M c4 c4 ;; . ;.4 t!1 C0WCOCOOD0000W0000WCDW 00 W W CD CID W OD OD W W W W W OtolncooroDWODO101 . . . . . . . . . . . . . • . . . . . . . . . . . . . d' ''1NNMMMMMMMMMMMMMMMMMMMMMMM CO W OD OD W OD W W W CO W W W W W OD OD aD W W W W W W W 00 x In ArgInna000.-INNMMM-w cry -w w In in In %o %0 %D r r, M r. N N N N M M. M M M. M M M M M M. M M M M M M M M M M W-P--CO-B OD 00 CO W W W W W W W 00 00 OD CD 00 CD OD 00 00 W W CO O N1D W O10HNNMMMd'a}qw-v-w vInInInIntD W to%o 0 H rl r1 _; N N N N N N N N N N N N N N N N N N N N N CD W W W W CO 00 W W CO W OD OD W OD OD W COW CO W W W W 00 W In In in ONc4cn vIn0nrn co W W 00%Ct00 m000000 N 0%C;C.44444t.4444H.H.4H.H.".4 C4(4N4NN r 00 0D OD 00 W O0 W W OD OD 00 CO W W CO CO CO W O0 0D OD W W W W O vIn O MIn%0 W W 0%000.-1.-IH.q N N N N M M M M MM . . . . . . . . . . . . . . . . . . . . . . . . . . N co OI0000000rl rl rl.-1 rl rl rl ri rl rl rt 4 H 4 r; r r CO 0D W 00 00 00 00 OD W 00 00 W 00 W W W W W W W W W W W In W N OD -1 v In n n W O% 0% 0 0 ri rl .d .-I r1 CV C4 C-4 m c l M M M . . . . . . . . . . . rt to W W O1O1p1O1O�0/010. 0. 00. 0. 0. 0. 0. 0. 000. 0. 00..0 . rrrrrrnrnnrWCDOD0OWWWWWWWWWWW O tD M o eP n 01 O H N M M d r In In In to to 1D to to n n 1D tD to . . . . . . . . . . . . . . . . . . . . . . . . . . �tornr9DoaoDOWWWWWWWWWWWWWWWWW rnnrnnnnrnnrnnrntnnrnrnnnrn InO. 0 -w0r-W co nnntD%DtoinwwMMNNOtoYr 0%w O. N N N N N. N N N N N N N N N N N N N N r. rr. 4 O O. n r r r r r r n r r n n r n r n n r r n n n r r n n x_ OE-4 o0000000000000000000000000 Wk, rI N M 40 In%On W at OHNM sr In ton W O1 o In 0In 0 tno a".-IrIrIrlrlrlrl.irlrtNNMMeYtI'In 8.4 DESIGN CRITERIA A 1 I 1 1 1 1 1 1 1 i I 1 1 1 1 1 1 O �- F p- g g 8 g 8 Q C vi C �n M F F O O h v -a u� C5 o ¢vu¢wau� K 0 0 z z .. • O v z g z (n ° �7 < ¢ Z z 0 > 3 .� Orx �wz o F o W oz O x -�-a� F x a U g F F a° ww N ay w O¢ O O F O vE"i 8 O .w m Ln v' a¢ ppz O F a a `� a oaC w x v j z 'o W F 0 94 O 0 8 Northern Engineering CuENT JOB NO SeMces, Inc. CALCULATIONS FOR Fort Collins. Colorado 80521 MADE BY pAT�� / �, �y NECKED BY DATE SHEET OF i �^—Lc TS i� � � i�r • �/lN-'13 �"y.1 S7"aP-N� �(�/a-A'+'�/ o'c!i C ��'is-1 �i C`%L'7 4sv � . I if i -✓I M I �J ':i - I i I I I i I I I I I I i I I 4NIatX _ so. I I j I I 2- i i j-Po,✓t I f� i - li!S L. .' i-;'�L ji IMP-' i4 Its C of 3i �.JrTI�Ei^I n ! 3' I.ZSi = '1-75 tnnc i y; ivrulJ. ' I i , f I+c�,✓1 �I !/11�s�.lh'C� ' �.�T,�'��-•-ii�' 1 I 1 I IJo MM I 1= s,� ✓1 tnr ! of '� � l • o' 3.Oi' H rc ��.c�' !M r,�/ I I f i • 1 I � ' ; I I ' i 1 � I ' j I I : I � No Text I DRAINAGE CRITERIA MANUAL ¢. RIPRAP Use Do instead of D whenever flow is supercritical in the barrel. **Use Type L for a distance of 3D downstream. FIGURE 5-7. RIPRAP EROSION PROTECTION AT CIRCULAR CONDUIT OUTLET. 11-15-82 URBAN DRAINAGE 5 FLOOD CONTROL DISTRICT I7I 1 53 Circular Channel Analysis & Design Solved with Manning's Equation Open Channel - Uniform flow Worksheet Name: Landings P.U.D. Comment: Storm Sewer Line D1 Solve For Actual Discharge Given Input Data: Diameter.......... Slope ............. Manning's n....... Depth............. Computed Results: Discharge......... Velocity.......... ' Flow Area......... Critical Depth.... Critical Slope.... Percent Full...... Full Capacity..... QMAX @.94D. Froude Number..... 11 I '1 1.25 ft 0.0045 ft/ft 0.010 1.18 ft 6.06 cfs 5.06 fps 1.20 sf 1.00 ft 0.0055 ft/ft 94.00 % 5.63 cfs 6.06 cfs 0.63 (flow is Subcritical) Open Channel Flow Module, Version 3.42 (c) 1991 Haestad Methods, Inc. * 37 Brookside Rd * Waterbury, Ct 06708 I 19 1 1 f 1 1 1 FINAL DRAINAGE REPORT HEART SPECIAL*--IMPR. DISTRICT CITY OF FO COUNTY OF LARIMER STATE OF COLORADO DECEMBER, 1984 REVISED: JANUARY 1985 PROJECT NO.: 311.2 Prepared by: Engineering Professionals, Inc. 2625 Redwing Rd., Suite 110 Fort Collins, CO 80526 (303) 226-3852 8 11 ' INTRODUCTION This final drainage report is submitted in conjunction with construction drawings for Heart Special Improvement District prepared by Engineering Professionals, Inc. The City of Fort Collins "Storm Drainage Design Criteria and Construction Standards" were used as guidelines for runoff calculations and storm sewer system design. SITE DESCRIPTION Heart Special Improvement District is located in the West half of Section 36, Township 7 North, Range 69 West of the Sixth i" P.M. Proposed improvements consist of construction of portions of JFR Parkway and Troutman Parkway, realignment of the Larimer #2 Canal, construction of a 5-foot by 20-foot box culvert under the intersection of JFR and Troutman Parkways, and construction of water, sanitary sewer, and storm sewer utilities. Future land use in the District will primarily be commercial and business -related, although approximately 10 acres in the southeast portion of the District is intended to be developed as high -density residential. The District contains approximately 45.3 acres, is predominantly covered with native vegetation, and slopes to the south and east at from .5 to 2%. The site is bordered on the north and east by Boardwalk Drive, on the west by business and residential properties, and on the south by agricultural land. The Larimer #2 Canal crosses the site in a general northeast -to -southwest direction. IHISTORIC DRAINAGE Before construction of the Landings and Whaler's Cove residential areas, the portion of the site below the Larimer #2 Canal drained to the major basin thalweg to the south, while the area above the Larimer #2 Canal discharged into the canal. At present, the majority of the site drains into the Larimer #2 Canal, a portion drains south toward the basin thalweg, and the remainder drains into an open channel leading to Harmony Reservoir (see Figure 1). Estimated historic 2-year and 100-year peak discharges into the Larimer #2 Canal from the site are 5.9 cfs and 20.5 cfs, respectively. Estimated 2-year and 100-year historic peak discharges from the site area below the Larimer #2 11 Canal are 4.2 cfs and 15.5' cfs, respectively. I !!ASTER DRAINAGE A report entitled "Master Storm Drainage Report for the Landings P.U.D.," by Cornell Consulting Company recommended that ' areas above the Larimer #2 Canal be allowed to release storm flows at the historic 2-year level directly to the Larimer #2 Canal. Those portions of the site below the Larimer #2 Canal, with the exception of Troutman Parkway, were to drain into an open channel running to Harmony Reservoir, as outlined in the above report. ' DRAINAGE UNDER DEVELOPED CONDITIONS ' City of Fort Collins Storm Drainage Utility staff has recommended that the Larimer #2 canal running through the site be sized for flows and a total discharge of 240 cfs, 155 85 cfs of stormwater flows. Assuming cfs of only irrigation those areas above the canal and to the east of College Avenue, (with the exception of the Jetty P.U.D., which discharges to Harmony Reservoir) contribute to stormwater discharge into the canal, the allowable release rate per tributary acre is approximately 0.87 cfs per acre (see Figure 1). We request that the City of Fort Collins require all future developers in this basin east of College Avenue above the Larimer #2 canal to design and construct facilities sized to detain the developed 100-year runoff volume and release at a rate of 0.87 cfs per tributary acre. ' Curb inlet lengths were sized for the 10-year event according to City of Fort Collins Drainage Design Criteria. Storm sewers discharging from future building sites into curb inlets were sized based on a detained release rate of .87 cfs per acre summed with any offsite discharge. The remainder of the storm sewer system from curb inlets to the Larimer #2 Canal were sized to handle the larger of the peak discharge from the 10-year street runoff intercepted by the curb inlets, or 10-year peak discharge from the total tributary area assuming a time of concentration of 20 minutes. ' According to recommendations made in the Cornell Report, those portions of the District below the Larimer #2 Canal (basins ' H, I, and M; see map) were to drain undetained to Harmony Reservoir via a grass lined, trapezoidal channel. Due to circumstances unforeseen during preparation of the Cornell Report, we propose that detention facilities sufficient to detain the 100-yearevent and releasing onto "Somerset" at the 2-year historic rate be constructed by future developers of basins H, I, and M. An undeveloped area of 3.6 acres at the Northwest corner of Landings Drive and Boardwalk discharges under Boardwalk via curb inlet and culvert onto Basin E. The inlet and culvert were sized by others based on undeveloped conditions; future developers of that parcel will need to detain on -site to limit future discharges to .87 cfs per acre, as this area historically ' discharged into the Larimer #2 Canal. We assumed that these undeveloped flows passed through Heart S.I.D. undetained to the ' Larimer #2 Canal. ' ENGINEERING PROFESSIONALS, INC. Jonathan B. Howard ' Michael N. Schmid, P.E. ' JBH:psm I I III I i Y tl %j �.. - • Wlu 1 ka i • c � I Q r. j d NO/AI �.+ A•i 1'' 1, / r / •as� P� \\ M: W rr i 1-4 s41 1 4 Y i•. Q Y _ � J � Im ♦ p w / I I •N `/ • ' : I I I tl �. . WA IV .793T70J a Pao 2 Y♦' _ �...mL ,Na3Hln s ONV 00Y O7 J -.� LPI:.- III d i I .i—_ •�` :l t i ­VDfL Ct•• ,tl• • • a i• °• / Al ' August 10, 1993 Mr. Glen Schlueter City of Fort Collins Stormwater Department 235 Mathews, P.O. Box 580 Fort Collins, CO 80522-0580 1 Re: ShopKo P.U.D./JFK Parkway Oversizing Project No. 10-724-000 Dear Mr. Schlueter: ' We are writing this letter to address the drainage facilities associated with the oversizing of the JFK Parkway adjacent to the ShopKo P.U.D. The City Engineering Department has ' indicated that ShopKo will be responsible for designing and constructing 100 L.F. of full width (70 feet FL -FL) asphalt and the associated curb and gutter on the east side of JFK Parkway at the intersection with Boardwalk Drive. From this point, a temporary asphalt ' taper will be constructed to the north to end in a 35-foot paved roadway. On June 21, 1993, myself and Rich Dvorak (TST, Inc.) met with you, Mike Herzig and Kerrie Ashbeck of the Engineering Department to discuss the particulars of this portion of the ShopKo site. We discussed several options for dealing with the drainage issues and _ settled on the following: 1. The east pond has approximately 2.5 feet of freeboard so it has some excess capacity. f 2. If we can assume that the site on the east side of JFK Parkway will be graded such that it will drain away from the intersection, a permanent curb inlet can be installed directly opposite Inlet #5 shown on the ShopKo P.U.D. Utility Plans. 3. If the pond has the excess capacity and the pipe sizes, as designed in the Drainage ' Report for the ShopKo P.U.D., do not increase, the new inlet could be permanently tied to ShopKo Inlet #5. ' 4. All of the above would be contingent on the site to the east not allowing any more runoff to reach the new inlet than what would be expected from a sub -basin covering the area from the high point on JFK south to Boardwalk, and from the centerline of JFK to the east right-of-way line. Boardwalk Drive slopes downhill to the west as it crosses JFK Parkway. Boardwalk has no crown, so runoff sheetflows across the street from north to south. There is an existing curb and gutter on the north side of the street and the gutter will carry nuisance flows west to College Avenue: Mike Herzig indicated that a cross pan in JFK is not an option, so the nuisance flows will have to be routed around the curb return and into the new inlet. TST, INC. 748 Whalers Way • Building D 102 Inverness Terrace East ' Consulting Engineers Fort Collins. CO 80525 Englewood, CO 80112 (303)226-0557 (303)792.0557 Metro Denver(303) 595.9103 FAX (303)792.9489 FAX (303) 226-0204 TST, INC. Mr. Glen Schlueter August 10, 1993 ' Page 2 I fl Our analysis was based on the previously mentioned scenario. We assumed a sub -basin identical to Sub -basin L in the Final Drainage Report for the ShopKo P.U.D. and will call this Sub -basin Ll. Runoff was calculated using the rational method and peaks for the 10- year and 100-year storms were derived. Although the proposed inlet, Inlet #5A, is technically in a sump, there is only a minimal ponding. depth available because of the lack of a crown in Boardwalk, so the inlet was analyzed as an on -grade inlet. Our analysis indicates a 17-foot inlet would be required for 100 % interception; however, we are suggesting a 15-foot inlet be used. The available ponding depth should be enough to keep the passing flow (less than 0.50 cfs) from entering Boardwalk. The proposed Pipeline B1 linking Inlet ##5A and Inlet #5 was calculated manually using a variation of Manning's Equation. A 15" diameter RCP will be more than adequate. Line B of the ShopKo P.U.D. Utility Plans was regraded to accommodate the connection of Inlets #5 and #5A and the capacity was re -checked. It turned out that the original 15" pipe would suffice, but the contractor needed to order the pipe some time ago, so as a worst case scenario, we indicated a pipe size based on a minimum grade which is a 24" RCP. All of the pipes down stream of Inlet #1 were adequate to carry the additional 2.76 cfs. The additional flow into the ShopKo P.U.D. east pond was analyzed and results in a peak inflow of 43.17 cfs during the 100-year storm and leaves 2.0 feet of freeboard. We believe this system satisfies all of the City of Fort Collins Stormwater Utility Design Criteria. The following pages show the calculations which support the information we have previously presented in this letter. It should be noted that the property to the north, when developed, can direct no more than 2.76 cfs to this inlet during the 100-year storm if it is to remain connected to the ShopKo system. If you have any questions or comments, please feel free to contact us. Sincerely, ' TST, INC., CONSULTING ENGINEERS ' tephen F. Human, P.E. ' DL/lc 1 1 L n Dave Lindsay 0 No Text TARANTO, STANTON 3 TAGGE (OZ Consulting Engineers CLIENT JOC[ /FiGr%VJOBNO. PROJECT-5L'201�ZR CALCULATION$FOR 5cA961 t5/'-U/%1— MADE BY'/�%L DATE `'�J3 CHECKED SY DATE SHEETOF UN nFF G0507r}Bt � ( i FINAL DRAINAGE REPORT FOR HIGH POINTE P.U.D. LOCATED AT •-BOARDWALK DRIVE & LANDINGS DRIVE FORT COLLINS, COLORADO REVISED 8/22/89 I TO BE DEVELOPED:BY: FAIRFIELD HOMES LAKEWOOD, COLORADO 11 IPREPARED BY: PARSONS & ASSOCIATES ' 432 Link Lane Plaza IFort:Collins, Colorado 80524 (303) 221-2400 PROJECT NO. 89.10 JET 1 �r FINAL DRAINAGE REPORT FOR THE HIGH POINTE P.U.D. INTRODUCTION This drainage investigation has been performed for the purpose of providing design information for the development of the High Pointe P.J.D., a residential development to be located at the northeast corner of the intersection of Boardwalk°Drive and the Landings Drive, Fort Collins, Colorado. The City of Fort Collins "Storm Drainage Design •Criteria and Construction Standards" was used as a basis for guidelines and criteria throughout this investigation. SITE DESCRIPTION The High Pointe P:U.D. is situated in the West one-half of Section 36, Township 7 North, Range 69 West of the 6th Principal Meridian, City of Fort Collins, Larimer County, Colorado. The site is bounded by Landings Drive on the west, Boardwalk Drive on the south and by Larimer County Canal No. 2 on the north and east side. The site contains approximately 12.15 acres. Eighteen (18) single family residential lots along with open space are proposed for. the site. . HISTORIC DRAINAGE A ridge line separates existing flows on the site with approximately 1/2 of the site draining northerly to Larimer County Canal No. 2 and approximately 1/2 of the site draining easterly to 'Canal No. 2. Approximately, 1.38 'cfs flows to Canal No. 2 downstream of the existing check structure. An area of 0.68 acres to the south of the Landings Drive flows to this site (2.75' cfs), and will be directed through detention Pond "A" and on through to Larimer County Canal No. 2. DEVELOPED CONDITIONS In compliance with, the Master Drainage Study prepared by Cornell Consulting Company for The Landings P.U.D. dated January 1979, the release rate to.the Larimer County Canal No. 2 will be restricted to the 2-year historic rate and detention will be provided on -site to accommodate the 100-year developed flows. Runoff coefficient used for the developed site is 0.45. Detention has been provided for a portion of Landings Drive and Boardwalk Drive which are. adjacent' to the site., Total release from this site into Canal No. 2 is 6.09 cfs. (2.09 cfs from Pond A,•1.25 cfs from Pond B,& 2.75 cfs from off -site area-0-1) Detention required for this site is-49,000 cubic feet. (18,200 cubic feet in Pond:A, 30,800 cubic feet in Pond B). Landscaping ponds are to be lined, and water supplied to be domestic. All required permits shall be acquired from the state. No water from ponds is to be released from landscaping .ponds to the storm drainage system. Ground water is 4.0 to 4.5 feet below finished grade at Pond B and 1 8.0 feet below finished grade at Pond A. r. There exists a check structure which diverts flows fromlthecanal to Warren Lake_ From the previously approved Jetty P.U.D. -plans dated January,"1986. ..There was 1.85 cfs released into Canal ■ .y .:.No.' 2 downstream of :the .check :structure.- -In the Heart "Special ® :;4-Aiproveient'District and "in the improvement of Canal `No."2; .;.release rates' -..for all areas draining to Canal No. 2 have been limited to"0.87 cfs per developed acre . When Fort Collins Retail Center .was `developed, runoff from 4.03 acres was piped :under"the canal and allowed to outf all in an open :field to the east. At 0.87 :'cfs ^�per,.Z_acre (and 4.02 -acres), this should allow an "'''additional 3.5 cfs to be released into Canal No. 2 downstream of the check structure without impacting anticipated design flows. The present design of this 'site. allows for the release of 1.38 cfs downstream of the check structure, to match the historical condition. This is 0.47 cfs less'than the previously .' approved plan of this site and is.2.12 cfs less than the unused capacity of the Canal from the Fort Collins Retail Center. W IA-9224.ESM ' DESCRIPTION FOR DRAINAGE EASEMENT That portion of the West Half of Section 36, Township 7 North, ' Range 69 West of the 6th P.M., Larimer County, Colorado, described as follows: Considering the West line of the Northwest Quarter of Section 36 as bearing North and South and with all bearings contained herein relative thereto. ' Commencing at the Northwest corner of said Section 36; thence South 28"44132" East 2772.12 feet to the intersection of a 20-inch CMP drainage pipe with the Southerly right-of-way line of Boardwalk Drive and the True Point of Beginning of the centerline of a 10- foot drainage easement. Thence along said drainage easement centerline South 26"4410011 East 22.54 feet; thence South 25"131301' East 18.58 feet to the beginning of a tangent curve concave to the Northwest, having a central angle of 53"31'07" and a radius of 200.00 feet; thence Southwesterly along the arc of said curve and continuing along said easement centerline 186.82 feet to the beginning of a tangent curve concave to the Southeast, having a central angle of 27"511'58" and a radius of 161.60 feet; thence Southwesterly along the arc of said curve and continuing along said easement centerline 78.60 feet; thence tangent from said curve and continuing along said easement centerline South 00"251139" West 480.00 feet to the approximate centerline of the Larimer County Canal No. 2 and the terminus of said easement centerline. The sidelines of said easement to be shortened or lengthened to meet with said Southerly right-of-way line of Boardwalk Drive. r I I I I I I ' LICENSE TO ENTER PRIVATE PROPERTY THE CITY OF FORT COLLINS, a Colorado Municipal Corporation, is ' the owner of certain real property in Larimer county, Colorado, legally described in that Treasurer's Deed recorded at Reception Number 02066317 in the Larimer County Records, does hereby grant permission to Lagunitas Landings. Inc., its employees, authorized agents, contractors, and assigns to enter the property shown on Exhibit "A", attached hereto and incorporated herein by this reference, for the sole purpose of constructing a storm drainage Swale in accordance with the Utility Plans for Landings Office Park P.U.D., dated July 7, 1995. ' As a condition of granting this license, the Grantee agrees that upon completion of these construction activities remaining portion of the above , the -described property will be restored to its former condition at the Grantee's expense. THE CITY OF FORT COLLINS, a Colorado Municipal Corporation ' Date: 3 4City ana ATTEST: City C r ` rA PROVED A8 TO ORM; Ass stant City Atto ney GRANTEE: LAGUNITAS LANDINGS• INC. Date: ATTEST: Title: 1 p.01 SEP-S1-`�3 MON 13:36 July 14, 1995 City of Fort Collins 281 K College Fort Collins, CO 80525 RE: Landings Office Park Storm Drainage Dear sirs: We have looked at the drainage plann for hhiproject pro project and are our n agreement with how the proposed storm water Will proceed One exception we have is that we ditch and that the grassy p4� be constructedie to withtnpr putorog out, as be continued directly into th shown. Furthermore, we agree to indicate our approval to the landings Office Park storm drainage plan by our signature on the plat. Yours truly, ehn Strachan President, Ladmer Canal #2 EXHIBIT A DRAINAGE EASEMENT rtw �LMMOS CFMCE Q ►AM P.". -Ar C.M.P. 82e'470� , to II f� f � Ltelf.e�R swot or c 1 eoo2ODSoI°o° 4 15 LCI W 10Roa'w eii,st��ep�pRR CDS130 , 100 ., 20U ti - / F ii W I ffFj CAZZQ'I' 1� NOTE: THIS DRAWING IS NOT A "LAND SURVEY PLAT" AS DEFINED BY COLORADO REVISED STATUTES 38-51-107 AND SURVEY MONUMENTS WERE NOT SET FOR THIS PROJECT, IT IS FOR PRELIMINARY INFORMATION ONLY. SCALE DATE I DRAWN I REVISED I FILE NO. EXHIBIT SHEET 1'W100� ... CP-1/ RB A9130EX1 LANDSTAR SURVEYING INC. 1327 N. Uncoln Ave. • Loveland, CO 80537 • (303) 067, 420� • fA 3�. 687-71b1;1 _... ,:.- • :�, Imo.+<,�rr;(�1R I ` 1 0 ' 3� I p I Y = Z jr I 0 eraPY M`/DE w YV 821 . I .' K MR IM RC I a g V, I I MUM 15' CURB WLE! FFLOLIN.. 5w5.15 1 Y - 65 ECSIMG 15' CIIRO WIET I I ,I, M'.EIMV 5M5:0] I I W'1` OUT. Cw307 I -I / \ j \ Y MR 55 45 pEC OENO W/ dCWO II!'/.. 5045.44 I 12,W V, MR TAM W. B BEND- pµ44 ( ( Im. My- su4e.13 BASH D3 DETAIED N EAST I �?;.� Q ` \• /bry /////I DETENTION POND OF SHOPKO PAW. i \•\ / DRAINAGE REPORT ADDEM M, Z7e CFS. r \�� O� \•\ ///NrNNlryb A5 //////i�ip' WE $W£! 0 Or 14 OF \ \ \ ///b/I DR SOAROWN IUVROY m 05TAMt \ \ .III' s021 \ RµS. FOR STREET CROWN LCGTgN9.�WP "•. (ea SOW/ �\ \ file, 4ry II IND. CORE I � �\ am O W-51.50 / r MELu r m D c1RVEM 5 ' TO �LAFV" COUNTY #2 CANAL w 2l Gml£t KSPAWX (WE oEruL sxEET a HiaH PONIE P.VD. I MENTION POND 'A' I PROPOSED DETENTION ' !' - { y� �\ p �ry� POND D4 {I, V A\,JY91 V! 5061.JWS E 3 9 CKI /41•.UNIDIEFA�+D TQ /� YVI. wUxc REVRO+ 1,181 CS. \\ G 1 •/• /� WLUC PIgM(- 42W CADELEY- QLED \ 11 I 1 1 @ p o.R cfs IL 0 01 1 x \ it �POND IIMOW MR JSE s22 EfiuL $NLx o) 1 11 y1 Y I (SEE krM AT PoGM) = BwONO 8 I e1iOHO 4 I I T 4PPROX rr-53.5 IPPROE fi.49.5 - D4 Y ; ; 1 04FEW 51 t Of THE w THE IN YR=WfF PROW 1 PI VER / 1 1.1 /4EL. � .. L r -�➢ IATeL /�IIOYIEx2 JP4P 1 14 PSIw .5 (SEE oErq s145ui; 0} ua w/4f . p.+ �I IW/ �m D Ep _ f 0 47 1 ` L` ffI 11 GAO(RE W, 6)EN OO •Ln - g t.03 I FI I 11 V �.. �Y MRK . 1 F .. ... , f .. .. ... • .. .�. �I ��..40 P F.., U.S. POST OFFICE 06 :: D4 4RQJ1.4 NWYF vi N '•i \ ........... PC• W24 1F. IV 1 E 1 /DSN-1E bi1X W W2 L 1 p I1rv. aur- Swl b 50 ® ( n r t z •L D7 •'. _ / -3- TOTAL ME OPED C2RANACSE AREA ` 1 r / TRIBUTARY TO L.ARI.IEH COLAYTY 02 CANAL TA6L.E A DST &$W DI- o24 M R sW Do.z9Ac 03 uvN N. O,o S5D 4C w- AC 8XRR D0- O.SN SPOW MIN X W.9N on ales AC BWH W. aW2 WC . M4N PJ. IAAeA ...' \ - W1 3.743 C DEVELOPED DRAINAGE BASINS 5vds 1- l00 Nma C '~X FA45.5 4z otvo p tnmoR1 4W44 0 02 O2. 0204 0.5 '1.9 PoN 19. ' D3 O3 one D.2 2.3 EAST POWIS OFSOIIfflI w Di 0350 1.1 3.4- 05 04W .1 39 M-9 OS OS O.SW 0.0. 3.3"DEFWmwES D] 07 a185 0.4 1.6 oR OAST 62 -MV FOXO w w DtA5.07.W.09 M2. 6,0 22T.. FOND 01 - --D W.NAFF n o:}54 79 17PoHD'A'' aFF- NORTHERN ENGINEERING SERVICESI PFOjEC` 420 SOUTH HOMES SUITE 202, FT. COLLINS, COLORADO 80521 I SCSIALEe 4 OECNEF (303) 221-4155 tlfi OCT 3 0 1995 t 5 P DS ISO Iy,Fp{s o15. RCP ^zvl,4 BKanT P2E1 - W39:zs PR(W. IT W AT OUTLET �\ TO LAF ER Ca �\ � w Ex IT W PA 0.372 CFS SA2/ CT TO W5)- 3tI55 U.F. v� SECTION A -A x.us. #8 CANAL 10' OFF -SHE MMW4 WEMFNT HE 2.0 NOTICE IT L ERING sTOIM1TATIR Pam v N 116 1.5' PAIIRIIIJ AlOIANO A NA 0l 131 �I.. (2T WGN LETTERING) Ir �iCL /ice LEGEND -�� EXISIMG STORM SEWER «� PROPOSED STORM SEWER Exlenw STDPY uRmwE INLET �.+ PROPYRA) WNW DW.IWGE INLET I1111111111111111 AWN ORO(40F EUM -' EX5N11CW FLOW PATTERN -55- FROWNED Comm 1 MA OmGWNR O, MFA N1 4GRES ® DFSgN PONT �u�u� E53TNA •4-m+�� PRakmrmlMpTr L;WN lorr � GRAPHIC SCALE 30 �Eie�l ao DITCH CO, APPROVAL BLOCK LARWER CANAL CO. . CANAL NO. 2 �c CITY APPROVAL BLOCK: CITY OF FORT COLLINS„ COLORADO UTILITY PLAN APPROVAL wPR�Xw WE HE& AM dWR m w ex�muw '- wT- CNECXm BYr G xO. M3M'OIMi wl m M w IT CHECKED W. IDINGS OFFICE PARK P.U.D. FINAL DRAINAGE PLAN