Loading...
HomeMy WebLinkAboutDrainage Reports - 01/19/2010NORTHERN N. = ENGINEERING ADDRESS: PHONE:970.221.4158 WEBSITE: 200 S. College Ave. Suite 100 www.riorthernertonee6ng.com Fort Collins, CO 80524 FAX: 970.221.4159 Drainage Letter Report Date: August 19, 2009 3� "k1 Project: 317 Wood Street Lot 5 & Lot 6, Block 303, Capitol Hill Addition Fort Collins, Colorado Attn: Mr. Wes Lamarque City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, Colorado 80521 Dear Wes: Project No. 110-043 This letter serves to address the stormwater impacts of the above referenced single-family residential home project. Lot 5 currently contains a lone residential dwelling structure as well as a detached garage accessed from the alley. Lot 6 currently contains two sheds and minor concrete flatwork. The proposed redevelopment will create two (2) free-standing single-family residential homes fronting Wood Street with detached garages accessed from the rear alley; one each on Lot 5 and the other on Lot 6. (See attached Grading Plan for further details) Table 1 below summarizes the pre- and post -construction impervious areas. Detention is not required since the total increased impervious area is less than 5,000SF. Table 1 - Impervious Areas LOT 5 LOT 6 Surface Existing Proposed Change Existing Proposed Change Rooftop house 1,105 SF 1,524 SF 419 SF 0 SF 1,411 SF 1,411 SF garage/shed 536 SF 704 SF 168 SF 316 SF 812 SF 496 SF Porch/Patio 505 SF 269 SF -236 SF 0 SF 256 SF 256 SF Conc. Walk 612 SF 76 SF -536 SF 127 SF 75 SF -52 SF Conc. Driveway 387 SF 480 SF 93 SFJ 0 SF 508 SF 508 SF Totalsi 3,145 SF 3,053 SF -92 SFJ 443 SF 3,062 sF 2,619 sF TOTAL INCREASED IMPERVIOUS AREA (LOTS 5 & 6) = 2,527 SF Although stormwater quantity detention is not required, stormwater quality mitigation will be addressed by both temporary and permanent Best Management Practices (BMPs). During construction, the Builder will follow the appropriate and applicable City of Fort Collins standards for erosion and sediment control. Post construction water quality and erosion control will be achieved by a fully established and stabilized site. All areas disturbed during construction will receive permanent hardscape, landscape, or building structure. Page 1 of 2 D:\Fraje is\110-043\Drei(iage\Drainage-Lettei 08-19-09-dM: e f IWI)b NE I NORTHERN ENGINEERING Another element addressing the quality of stormwater runoff is the minimization of directly connected impervious areas. A large vegetated buffer strip exists within the public tree lawn; measuring approximately 17-ft along Wood Street. Additionally, roof drainage will be collected in residential gutter and downspout systems, and discharged on the landscaped surface. This will encourage infiltration, pollutant settling, and cleansing of runoff before it reaches the receiving waters in the adjacent curb and gutter. The grading plan closely matches existing elevations and drainage patterns, thus ensuring adjacent properties are not adversely impacted. Detention is proven to be unnecessary. Stormwater quality has been considered, and will be addressed in a sufficient manner. Therefore, it is my professional opinion that the two single-family homes proposed at 317 Wood Street (Lot 5 and Lot 6, Block 303, Capitol Hill Addition) satisfy applicable stormwater criteria. Please do not hesitate to contact me if you have questions or require additional information. Since -' Nicholas W. Haws, PE, LEED AP Project Manager CC: Aaron Everitt - Jamestown Builders Page 2 of 2 GRADING PLAN FOR LEGAL DESCRIPTION: LOT 5 & LOT 6, BLOCK 303, CAPITOL HILL ADDITION, FORT COLLINS, COLORADO FG=19.89 I FG=19.13 ( I / / LOT 6 ^/ / / 20 0 20 Feet ( IN FEET ) 1 inch = 20 ft. EVERITT COMPANIES CAPITOL HILL ADDITION No. RMSIDR By DATE NE NORTHERN ENGINEERING zmsm.w.e..s. im mo�srozzuxsa ru vrozxu,ss PROJECT Y: 110-043 BG: M DR M BY: AGR DATE: 811009