Loading...
HomeMy WebLinkAboutDrainage Reports - 02/01/2016No Text FINAL DRAINAGE REPORT FOR COLORADO STATE UNIVERSITY HEALTH AND MEDICAL CENTER JVA, Inc. 25 Old Town Square, Suite 200 Fort Collins, CO 80524 phone: 970-225-9099 JVA Project No. 2487c JANUARY 20, 2016 TABLE OF CONTENTS SITE LOCATION AND DESCRIPTION.......................................................................................4 DRAINAGE BASINS AND HISTORIC RUNOFF...........................................................................5 HISTORICDRAINAGE...................................................................................................... 5 DRAINAGE DESIGN CRITERIA.............................................................................................. 7 HYDROLOGIC METHOD AND DESIGN STORM FREQUENCIES .................................................. 7 HYDRAULICCRITERIA.....................................................................................................7 VARIANCES FROM THE CRITERIA.......................................................................................... 7 DRAINAGE FACILITY DESIGN.............................................................................................. 7 GENERALCONCEPT......................................................................................................7 PROPOSED DEVELOPED SUBBASINS..................................................................................8 PROPOSED DETENTION POND....................................................................................... 1 1 HISTORIC/DEVELOPED BASIN COMPARISON................................................................... 13 STORMWATER MODELING............................................................................................... 13 STORMWATER POLLUTION PREVENTION/EROSION CONTROL ................................................. 13 TEMPORARY EROSION CONTROL................................................................................... 13 PERMANENT EROSION CONTROL................................................................................... 13 CONCLUSIONS............................................................................................................... 14 REFERENCES................................................................................................................... 14 LIST OF TABLES TABLE 1. HISTORIC SWMM BASIN PROPERTIES AND FLOWS........................................................5 TABLE 2.DEVELOPED SWMM SUBBASIN PROPERTIES, FLOWS, AND RUNOFF COEFFICIENTS........... 11 TABLE 3. TOTAL SITE OFFSITE FLOWS AND CAPTURED OFFSITE FLOWS ......................................... 12 LIST OF FIGURES FIGURE 1. HISTORIC DRAINAGE BASINS (AYRES ASSOCIATES SWMM MODEL).............................6 FIGURE 2. DEVELOPED DRAINAGE SUBBASINS (SWMM MODEL)................................................9 Colorado State University Health and Medical Center Final Drainage Report Page 1 of 14 ' APPENDICES ' Appendix A - Referenced Information l . Urban Storm Drainage Criteria Manual Table RO-3 ' 2. CSU Medical Center Project Drainage Memo from Ayres Associates 3. Referenced Pages from the Alternative Analysis for the Design of the Mason Street Outfall Study from Ayres Associates Dated November 2010 ' 4. Geotechnical Results and Soil Boring Logs 5. FEMA FIRM Map Appendix B - Hydraulic/Hydrologic Computations 1. SWMM Input Table (Historic - Ayres Associates Model) 2. SWMM Results (Historic - Ayres Associates Model) ' 3. SWMM Input Table (Developed) 4. SWMM Results (Developed) 5. Pond Volume Calculations ' 6. Overflow Spillway Calculation 7. Restrictor Plate Sizing Calculations 8. Inlet Sizing Calculations ' Appendix C - Figures 1. Site Vicinity Map 2. Developed Drainage Map Colorado State University Health and Medical Center Final Drainage Report Page 2 of 14 ENGINEER'S STATEMENT: "I hereby certify that this report (plan) for the Final Drainage Design for the CSU Health and Medical Center was prepared by me (or under my direct supervision) in accordance with the provisions of the City of Fort Collins Standards for the Responsible Parties thereof. I understand that the City of Fort Collins does not and shall not assume liability for drainage facilities designed by others." W4. 1/20/16 Kevin A. Toner 10NAL Registered ProfesliOnc State of Colorado No. 28699 Colorado State University Health and Medical Center Final Drainage Report Page 3 of 14 SITE LOCATION AND DESCRIPTION The Colorado State University Health and Medical Center (site) is located in Section 14, Township 7 North, Range 69 West of the 611 Principal Meridian, in Larimer County, Fort Collins, Colorado. Refer to Appendix C for the site vicinity map. Lake Street (Lake) to the north, South College Avenue (College) to the east, West Prospect Road (Prospect) to the south, and the Mason Street ' Corridor Transitway to the west border the property. Colorado State University (CSU) is located to the north and west of the site. Developed commercial and residential areas are to the east and south of the site. The site is located in the Mason Street Outfall (MSO) and is included in the study performed by Ayres Associates in 2012 on the MSO design. The design requirements and constraints are outlined in the study and attached in Appendix A. The site is approximately 5.7 acres of developed residential properties with an alley bisecting the ' lot from north to south. The site currently drains in several directions with most of the flow directed to the south with slopes from 1.9% to 2.5% and east at a slope of 1.2% to the intersection of Prospect and College. A smaller portion of the site drains to the north at a 2.0% slope to Lake and to the west at slopes ranging from 1.8% to 3.8% to Mason Street. From the geotechnical report dated August 18, 2015 the soil is mainly sandy clay with areas of gravely sand and existing fill. Sandstone bedrock was encountered at 18ft to 24ft below the ground surface with ground water ' being located at 12ft to 19ft below ground surface. The summary of the conclusions of the geotechnical report is attached in Appendix A. There is a contaminated polychlorinated biphenyl (PCB) field located in the southwest corner of the site that cannot be disturbed. ' According to the FEMA Flood insurance Rate Map Panel Number 08069CO979H dated 05/02/2012, the site is located outside of the 100-year floodplain area. The map panel is attached in Appendix A. Runoff from the existing site enters into the existing storm sewer system at inlets on Lake, Mason, ' and on Prospect just west of College. Currently, as stated in the MSO, the pipe system at Prospect is too small to handle the existing flows and water ponds at the intersection of College and Prospect. Flows that are not captured on Lake Street are directed onto College and eventually to ' the inlets on Prospect. The MSO collects water on the Mason Street Corridor. The site construction includes approximately 41,300sgft building footprint and 27,000sgft parking lot area with associated utilities, roads, sidewalks, detention pond, and landscaped and plaza areas. ' A portion of the property located to the northeast of the site will not be developed at this time and is not a part of the overall site. However, the storm system was designed to accommodate future development of that area as a parking lot and is included in the site analysis. The site drains to the southwest corner of the property where the detention pond is located. The detention pond connects to the existing MSO storm system which outlets into a regional detention pond and eventually to Spring Creek and the Poudre River. Storm inlets and pipes are located throughout the site to ' capture and convey runoff to the detention pond. The main purpose of this study is to analyze the existing and developed drainage patterns in order ' to convey stormwater into the MSO as required by the MSO study and the City of Fort Collins. The proposed scope of work will include new storm piping, inlets, manholes, and site grading to ' Colorado State University Health and Medical Center Final Drainage Report Page 4 of 14 accommodate an on -site detention pond and conveyance of the stormwater runoff to the existing MSO storm system. An outlet structure consisting of a wing wall structure and pipe with a restrictor plate will be installed in the pond to control the 100-year storm outflow rate. A spillway is located along the south edge of the pond and will direct flow onto Prospect if the outlet structure is ever clogged or not performing correctly. DRAINAGE BASINS AND HISTORIC RUNOFF HISTORIC DRAINAGE The site's existing system was modeled in EPA's Stormwater Management Model (SWMM) by Ayres Associates and reported in the CSU Medical Center Project Drainage Memo dated July 30, 2015, attached in Appendix A. The SWMM inputs and results of the existing drainage system are attached in Appendix B. The site is within parts of historical basins El, E2, E3, E4, E5 and E6. Basin E1 drains to the north into Lake Street and is assumed to be collected by existing inlets on Lake Street. Basin E2 drains to the east onto College. The flow then travels south along College until directed west onto Prospect and into a set of sump inlet approximately 50ft west of College. Basins E3 and E4 drain to the west onto Mason where inlets to the MSO collect the flow. Basins E5 and E6 drain south onto Prospect and into the existing inlets. Currently the pipe system that the Prospect inlets tie into is undersized and ponding occurs for larger storm events. There is no existing onsite detention for the site. Table 1. Historic SWMM Basin Properties and Flows Drainage Basin Design Point Area (acre) % Impervious Width (ft) Slope (%) Q-100 (cfs) Runoff Coefficient E1 Lake St 0.92 39.0% 200 2.0 6.4 0.76 E2 College 1.13 49.0% 328 1.20 8.8 0.80 E3 Traintracks 0.67 50.0% 450 1.80 6.1 0.81 E4 Traintracks 0.34 0.0% 294 3.80 2.8 0.64 E5 Prospect 1.86 22.0% 809 2.50 13.8 0.71 E6 Prospect 0.89 18.0% 516 1.90 6.7 0.69 Total S.81 31.3% 44.7 0.74 Colorado State University Health and Medical Center Final Drainage Report Page 5 of 14 ----------- • LAKE STRUT i WEST PROSPECT ROAD Figure 1. Historic Drainage Basins (Ayres Associates SWMM Model) Colorado State University Health and Medical Center Final Drainage Report Page 6 of 14 ' DRAINAGE DESIGN CRITERIA ' HYDROLOGIC METHOD AND DESIGN STORM FREQUENCIES The drainage for the site was designed to meet or exceed the City of Fort Collin's Standards and ' Specifications, including the Stormwater Criterial Manual which incorporates most of the Urban Drainage and Flood Control District Criteria Manual (USDCM). The EPA's SWMM model Version 5.1 was used to calculate the existing and proposed runoff rates and coefficients. The site's basin percent impervious values were calculated using impervious values from Table RO-3 in the USDCM. The City of Fort Collins' Stormwater Criteria Manual recommended values for the SWMM basin properties and Table RA-9 provides a 100-year event rainfall intensity duration curve that were used in the SWMM model. HYDRAULIC CRITERIA The proposed drainage facility has been designed to comply with the City of Fort Collins Stormwater Criteria Manual. SWMM was used to analyze the designed storm system, outlet structure, and detention pond. UDFCD's UD-Inlet v3.14 spreadsheet was used to design the inlet structures for the site. The SWMM results and inlet design calculations are attached in Appendix B. Complete drainage plans, details, dimensions, etc. are included in the grading and drainage plans in the site's construction documents. VARIANCES FROM THE CRITERIA ' As per the meeting on December 2, 2015 and the City's comments and response dated December, 4, 2015 the site does not need to follow the City's LID and paver criteria. The MSO system, as ' stated in the MSO study, includes 0.25 acre-ft of water quality capture volume (WQCV) for this site in its regional detention pond. This site has a WQCV of 0.129 acre-ft. Therefore, no water quality control is required on site. The minor storm event was also not controlled on site and the system was designed to capture and convey the 100-year storm event. ' DRAINAGE FACILITY DESIGN ' GENERAL CONCEPT The site's storm drainage system has been designed to convey the 100-year storm event through the combination of inlets, manholes, pipes, a detention pond and an outlet pipe with a restrictor plate. A SWMM model was created to model the proposed subbasins and storm system. The site was graded to capture runoff into the storm system and directed to the detention pond located in the southwest corner of the site. The site was graded to minimize the amount of flow being directed ' to College and Prospect. An inlet was added to College to capture flow and reduce the runoff going to the existing Prospect inlets. While the College inlet is not collecting runoff from the developed site, it is capturing flow that would eventually reach the Prospect inlets. Most of the ' runoff that was originally directed into the Mason Street Corridor is now captured in the sites system. Two inlets were added to Lake to capture the runoff from Lake Street and runoff from the ' Colorado State University Health and Medical Center Final Drainage Report Page 7 of 14 site that could not be captured on -site. The inlets will reduce the flow that is directed to the existing undersized inlets on Lake located near College. ' PROPOSED DEVELOPED SUBBASINS The site was delineated into fifteen subbasin, DI -DI 5, and were dependent on the location of the inlets throughout the site. The roof drains split the roof into nine subbasins that tie into the storm system. There is also an additional basin called DUMMYBASIN that represents the flow from ' College that can be captured in the College inlet, C213, and downstream restricted pipe. There are only three Subbasins D7, D8, and D15 that are not captured and conveyed to the detention pond. Subbasin D7 drains to the Prospect inlets, D8 drains to College and eventually flows to the Prospect inlets, and D15 drains to the existing inlets on Lake. The developed drainage map is provided in Appendix C. ' Colorado State University Health and Medical Center Final Drainage Report Page 8 of 14 Figure 2. Developed Drainage Subbasins (SWMM Model) SUBBASIN DESCRIPTIONS: • Subbasin D I contains the north half of Lake Street and drains to a 5 foot Type R inlet on Lake Street. • Subbasin D2 contains the south half of Lake and the sidewalks and landscape area along the north edge of the parking lot. This subbasin contains a portion of private property that are not a part of the site and will remain undeveloped. A 5 foot Type R inlet was placed in Lake Street to capture the subbasins runoff. • Subbasin D3 contains the site's main parking lot, access roads, and a section of private properties that are not a part of the site and will remain undeveloped. The subbasin drains into a 10 foot Type R inlet. Colorado State University Health and Medical Center Final Drainage Report Page 9 of 14 1 • Subbasin D4 contains a small parking area, landscaping, and sidewalks. The runoff is ' directed away from the building into the parking area and a 5 foot Type R inlet. • Subbasin D5 contains a small parking lot area, landscaping and sidewalks. The runoff is ' directed away from the building into the parking area and a 5 foot Type R inlet. • Subbasin D6 contains the detention pond, sidewalks and plaza area and landscaping. The runoff is directed away from the building and into the detention pond. ' • Subbasin D7 contains sidewalks, the Prospect bus pull out area, landscaping and the widened Prospect Road area. The subbasins runoff flow is not captured on -site, and is directed to the existing inlets on Prospect. • Subbasin D8 contains sidewalks and landscaping. This flow is not captured on -site and flows to the existing inlets on Prospect. • Subbasin D9 contains a plaza sitting area and landscaping. This flow is captured by an ' 18"x18" area drain. • Subbasin D10 contains parking spaces, sidewalks, and service area. This flow is directed to a 5 foot Type R inlet. • Subbasin D 11 contains the east portion of the private properties at the corner of Lake and College not included in the site boundary. The runoff flows to the east onto College and is captured by the proposed 5 foot Type R inlet on College, C213. This inlet is connected ' to the site's storm system by a 12 inch pipe with a restrictor plate that decrease the pipe diameter to 0.75 foot. The peak allowable flow into the storm system from College will be 3.43 cfs, as modeled in SWMM. • DUMMYBASIN: In order to model the collection and restriction of flow from College into ' the site system at inlet C213, the DUMMYBASIN was created. In order determine the peak runoff flow into the 0.75 foot pipe, pipe LIB, the DUMMYBASIN was sized as 100 acres with 100 percent imperviousness. ' • Subbasin D12 contains a landscaped area, sidewalks and a depression storage area. The depression area is designed to reduce the amount of runoff reaching Prospect. A 12"x12" area drain is located at the bottom of the depression and is piped into the detention pond. ' The calculated ponding depth is attached in Appendix B. • Subbasin D13 contains part of the plaza located to the southeast of the building. This flow is captured by an 18"x 18" area drain. ' • Subbasin D 14 contains sidewalks and a depression storage area. The depression area keeps runoff from flowing west onto the Mason Street Corridor. A 12"x 12" area drain is location at the bottom of the depression area and the drain ties into the storm system. The calculated ponding depth is attached in Appendix B. • Subbasin D 15 contains sidewalk and landscaping along the south side of Lake Street. This basin was included in the runoff calculations because the sidewalk width is being increased ' in this area. This flow will drain to the North onto Lake Street and into the existing inlets on Lake Street. • Roof Drain Subbasin: SD I, SD2, SD3, SD5, SD6, SD7, SD9, SD 10, SD 11. The roof drain ' locations, basin areas, and pipe sizes were supplied by the building architect. All the roof drains were tied into the storm system and drain to the detention pond. ' Colorado State University Health and Medical Center Final Drainage Report Page 10 of 14 Table 2.13eveloped SWMM Subbasin Properties, Flows, and Runoff Coefficients Subbasin ID Design Point Area acre (acre) % Impervious p Q-t00 (cfs) Runoff Coeffs C100 Discharge Location D1 1 0.14 100.0 1.32 0.98 Detention Pond D2 2 0.41 74.6 3.56 0.89 Detention Pond D3 3 0.96 72.1 8.91 0.88 Detention Pond D4 4 0.24 78.7 2.36 0.91 Detention Pond D5 5 0.32 86.7 3.15 0.93 Detention Pond D6 6 0.60 27.7 4.67 0.72 Detention Pond D7 7 0.43 69.0 3.62 1 0.86 Prospect D8 8 1 0.33 29.0 1.81 0.70 College D9 9 0.07 89.4 0.69 0.94 Detention Pond D10 10 0.35 93.6 3.47 0.96 Detention Pond Dl 1 11 0.39 49.9 2.66 0.78 Detention Pond D12 12 0.21 20.6 1.51 0.69 Detention Pond D 13 13 0.08 81.9 0.77 1 0.92 Detention Pond D14 14 0.16 50.7 1.28 0.80 Detention Pond D15 15 0.05 60.2 0.46 0.84 Lake Street SDI SDI 0.13 90.0 1.30 0.95 Detention Pond S132 SD2 0.13 90.0 1.30 0.95 Detention Pond S133 SD3 0.19 90.0 1.89 0.95 Detention Pond S135 SD5 0.07 90.0 0.70 0.95 Detention Pond SD6 SD6 0.09 90.0 0.90 1 0.95 Detention Pond SD7 SD7 0.19 90.0 1.90 0.95 Detention Pond SD9 SD9 0.04 90.0 0.40 0.95 Detention Pond SD 10 SD 10 1 0.05 90.0 0.50 0.95 Detention Pond SDI I SDI 1 0.04 90.0 0.40 0.95 Detention Pond Total or Weighted Avg 5.69 67.10 49.53 0.86 DUMMYBASIN N/A 100 100.0 46.32 1 0.48 Detention Pond PROPOSED DETENTION POND A detention pond has been designed to capture the 100-year storm event runoff from the site and ' discharge into the MSO system. Due to the existing grade of the site, the entire site runoff was not captured and conveyed to the storm system and detention pond. However, the inlets on Lake and College collect more offsite flow than the site's total offsite flow that not collected. According to ' the MSO the ponds outflow rate cannot exceed 13 cfs. CSU has requested a peak outflow rate of 11 cfs. The original MSO manhole that the site was designed to tie into was not used because of the PCB field located in the southeast corner of the site. The closest MSO manhole to the north of the original manhole will be the sites tie-in manhole. The detention pond ties into the MSO ' manhole at elevation 4989.27. The bottom of the pond is at an elevation of 4989.50 and is 7.50 feet deep with a total volume of 0.877 acre-ft at peak elevation of 4997.00. The pond's overflow Colorado State University Health and Medical Center Final Drainage Report Page 1 1 of 14 spillway is located on the southeast edge of the pond and will discharge to Prospect if the outlet structure of the pond is ever clogged or malfunctioning. The spillway was designed to be able to discharge the peak 100-year runoff rate into the pond of 44.50 cfs. The spillway was designed to have a bottom length of 40 feet, a width of approximately 10 foot, side slopes of 4:1 (H:V) and max water depth of 6 inches with 6 inches of freeboard. Access to the pond and outlet can be achieved by entering the pond from the south off of Prospect as there are retaining walls on the north and east edge of the pond. For the 100-year storm event the pond will have a maximum water surface elevation of 4996.12 feet which is a pond volume of approximately 0.635 acre-ft. This allows for 0.88 foot of freeboard. The maximum pond outflow rate is 10.97 cfs. The outlet pipe will be a 2.0 foot pipe with a restrictor plate reducing the diameter to 1.63 feet. There will be no water quality control within the detention pond because it will be controlled in the MSO's regional detention pond. Not all of the site runoff is being captured in the detention pond. However, by placing two inlets on Lake and an inlet on College an additional 0.64 cfs beyond the offsite flow is captured and conveyed to the detention pond instead of reaching the Prospect inlets, see Table 3. There are two existing undersized inlets on Lake that capture runoff from Lake. It was assumed most of the existing flow from Lake Street by-passes the existing inlets and continues onto College. However, by installing two new inlets on Lake and keeping the existing inlets, the runoff from subbasins D 1, D2, and D15 are captured before flow from Lake reaches College and eventually Prospect. To further reduce offsite flows to Prospect, an inlet was placed on College, inlet C213. The 12 inch pipe that connects C213 to the site's system has a restrictor plate on it to restrict the peak flow from College to 3.43 cfs. The pipes diameter will be reduced 0.75 foot. Any flooding of inlet C213 in the SWMM model is insignificant because it is assumed the inlet will flood once the restricted 12 inch pipe is at capacity. Table 3. Total Site Offsite Flows and Captured Offsite Flows Captured Site Offsite Basins Used Location Off(cfs)site Flows Flows (cfs) For Calcs Lake Street 2.70 5.34 D1, D2, D15 College Avenue 1.81 3.43 D8 Prospect 3.62 0.00 D7 Total 8.13 8.77 At this time the existing three properties to the northeast of the site will not be developed and are ' not a part of the site. However, in the future the properties may be purchased by CSU and developed. The current storm system and detention pond was sized to allow for the addition of this area as a parking lot. It was assumed that the backyard area of the properties would become ' 100 percent impervious and flow into the site's storm system. This would increase the percent imperviousness for subbasin D2 to 79.5% and D3 to 92.7%, all other basin attributes would not change. The future changes were modeled in SWMM and showed no flooding of the storm system. ' The detention ponds future water surface elevation would be 4996.15 feet which is a depth of 6.65 feet above the pond bottom. The future peak 100-year storm outflow rate from the pond and pond J ' Colorado State University Health and Medical Center Final Drainage Report Page 12 of 14 volume would be 1 1.12 cfs and 0.642 acre-ft, respectively. If desired, the restrictor plate height on the outlet can be manipulated to adjust the pond depth and outflow rate. HISTORIC/DEVELOPED BASIN COMPARISON The site contains six historical basins which drain runoff in all directions. The bulk of the site drains to College and Prospect where there are existing inlets on Prospect. The developed drainage basins will not drastically alter the historical drainage paths, but do decrease the peak flow rates to the Prospect inlets. Flow to the existing Lake Street inlets decrease from 6.44 cfs to 0.46 cfs with the installation of two inlets on the north and south sides of Lake Street. Flow to College decreases from 8.82 cfs to 1.81 cfs with the addition of area drains in the plaza area and an inlet on College north of Prospect. The inlet on College will be able to capture an additional 3.43 cfs, while being restricted by the downstream 12 inch pipe decreased to a 0.75 inch pipe with a restrictor plate. Only a small portion of the site's offsite flows will be directed to Prospect, the total peak flow to Prospect decreases from 20.48 cfs to 5.43 cfs. The flows captured by the proposed inlets on Lake and College will negates the offsite flows from College and Prospect that are not captured on site. The proposed total 100-year peak runoff for the site is 49.5 cfs with only 5.89 cfs of the site flow not being captured and conveyed to the detention pond. The detention pond has a release rate of 10.97 cfs. The existing site has a peak 100-year runoff rate of 44.7 cfs. In the event that the detention ponds outlet pipe is clogged, the pond's overflow spillway will direct flow onto Prospect. STORMWATER MODELING ' The pipes, perimeter drains, inlets, manholes and detention pond have been designed to convey the 100-year storm event flows without flooding the systems. The system has been modeled in SWMM to analyze the conveyance and capacity of the pipe system and detention pond. A copy ' of the SWMM model will be provided upon request. The detention ponds outlet was assumed to have constant water surface elevation of 4995.1 feet. This is the elevation of the 100-year hydraulic grade line in the MSO manhole that the detention pond outlets into. If the outlet pipe ' becomes clogged the pond will overflow to the south onto Prospect through the ponds designed spillway. STORMWATER POLLUTION PREVENTION/EROSION CONTROL TEMPORARY EROSION CONTROL ' A temporary erosion control plan is to be implemented for the site during construction. Temporary erosion control measures include, but are not limited to, slope and swale protection provided by the use of erosion control wattles/sediment control logs, inlet and outlet protection, vehicle t tracking control at access points to the site and silt fence surrounding the disturbed area. All temporary erosion control measures are to be removed after they are deemed unnecessary. Refer to the Erosion Control Plan for the CSU Medical Center Building for additional detail information. ' PERMANENT EROSION CONTROL Permanent erosion control measures include, but are not limited to, the constructed detention ' ponds, riprap pads placed for culvert outlet protection, seeding and mulch placed to enable and established vegetative growth, etc. Long-term maintenance of these erosion control measures shall ' Colorado State University Health and Medical Center Final Drainage Report Page 13 of 14 1 be the responsibility of the owner of the property. A general erosion control plan has been provided in the construction documents. CONCLUSIONS This Final Drainage Report for the CSU Health and Medical Center has been prepared to comply with the stormwater criteria set by the USDFCD and the City of Fort Collins. The proposed drainage system presented in this report is designed to convey the 100-year peak stormwater runoff through the site to the proposed detention ponds. Through calculations, modeling, and review of the proposed storm drain system, there appears to be adequate capacity to convey the proposed flows. This report also proposes best management practices for erosion control, permanent landscaping, riprap, and on -site construction facilities. It can therefore be concluded that development of the detention ponds comply with all of the stormwater jurisdictional criteria and will not adversely affect the existing streets, storm drain system and/or detention/water quality facilities. REFERENCES 1. Urban Storm Drainage Criteria Manual (Volumes 1, 2, and 3), Urban Drainage and Flood Control District, June 2001, Revised April 2008. 2. City of Fort Collins Stormwater Criteria Manual, City of Fort Collins, December 2011. 3. "Geotechnical Investigation Proposed Medical Center Colorado State University Fort Collins, Colorado", CTL Thompson Incorporated, Dated August 18, 2015. 4. "CSU Medical Center Project Drainage Memo", Ayres Associates, Dated July 30, 2015. 5. "Alternative Analysis for the Design of the Mason Street Outfall Study", Ayres Associates, Dated November 2010. 6. Stormwater Management Model User's Manual Version 5.0, U.S. Environmental Protection Agency, Revised July 2010. 7. Stormwater Management Model Applications Manual, U.S. Environmental Protection Ate, July 2009. Colorado State University Health and Medical Center Final Drainage Report Page 14 of 14 No Text ' DRAINAGE CRITERIA MANUAL IV. 1) Table RO-3—Recommended Percentage Imperviousness Values Land Use or Surface Characteristics Percentage Imperviousness Business: Commercial areas 95 Neighborhood areas 85 Residential: Single-family Multi -unit (detached) 60 Multi -unit (attached) 75 Half -acre lot or larger Apartments 80 Industrial: Light areas 80 Heavy areas 90 Parks, cemeteries 5 Playgrounds 10 Schools 50 Railroad yard areas 15 Undeveloped Areas: Historic flow analysis 2 Greenbelts, agricultural 2 Off -site flow analysis (when land use not defined) 45 Streets: Paved 100 Gravel (packed) 40 Drive and walks 90 Roofs 90 Lawns, sandy soil 0 Lawns, clayey soil 0 See Figures RO-3 through RO-5 for percentage imperviousness. RUNOFF CA = KA + (1.3Ili' — 1.44i' + 1.135i — 0.12) for CA >— 0, otherwise CA = 0 (RO-6) CCD = KCD + (0.858i' — 0.786i' + 0.774i + 0.04) (RO-7) CB = (C n + CCD)I2 2007-01 RO-9 Urban Drainage and Flood Control District Date: July 31,2015 Re: CSU Medical Center Project Drainage Memo Project Summary: The CSU Medical Center is located at the northwest corner of the intersection of Prospect and College Avenue. The project is bound to the north by Lake Street and to the west by the Mason Street Corridor. The project site is located in the Mason Street Outfall (MSO) study performed by Ayres Associates in 2012 which documents the drainage requirements for the site. The purpose of this drainage memo is to document the preliminary drainage analysis performed for the CSU Medical Center development. Mason Street Outfall Summary: The Mason Street Outfall was designed assuming that the northwest intersection of College and Prospect would drain into the Mason Street Outfall. It assumed the entire block, from Lake Street to Prospect would develop at 95% impervious and discharge into the MSO system at a maximum flow of 13cfs. The MSO project also assumed that water quality for the entire area would be provided in the water quality pond located in the BNRR pond at the outfall of the MSO system. CSU Medical Center - Existing Drainage: The existing site can be broken into six drainage basins. The following table summarizes the basin properties, 100-year storm flows and the discharge location for each of the basins. Table 1 Existing Drainage Basins Basin Area acres Impervious % Flow cfs Discharge Locations E1 0.9 39 6.4 Lake Street E2 1.1 49 8.8 College Avenue E3 0.6 50 6.1 Mason Street E4 0.3 0 2.8 Mason Street E5 1 1.8 22 1 13.8 Prospect Avenue E6 1 0.8 18 6.7 Prospect Avenue Page 1 of 4 CSU Medical Center — Proposed Drainage: The proposed medical center can be broken into fifteen drainage basins. The following table summarizes the basin properties, 100-year storm flows and the discharge location for each of the basins. Table 2 Proposed Drainaae Basins Basin Area Impervious Flow Discharge Locations acres % cfs Offsite basin that models P01 0.36 100 3.6 Lake Street. Flow being picked up with a Type R inlet on Lake Street. Basin drains to Lake P02 0.20 46 1.6 Street. Flow is being picked up with a Type R inlet on Lake Street. Basin drains to a single P03 0.46 58 4.1 Type R Inlet located in the northwest comer of the site. Basin drains to three area PO4 1.23 95 12.3 inlets located in the middle of the parking lot. Basin drains to a single P05 0.04 100 0.4 area inlet located near Lake Street. This basin is the existing development that is located on the site. The project does not include P06 0.45 41 3.6 this basin. However, a Type R inlet has been located along College to pick up the existing developments offsite flows. Basin is located at the northeast corner of the P07 0.21 84 2.1 proposed building. This basin drains to a proposed area inlet. Basin is located north of P08 0.37 85 3.7 the detention pond. This basin drains to a Type R inlet. Page 2 of 4 Basin Area Impervious Flow Discharge Locations acres % cfs This basin is the proposed P09 0.86 100 8.3 CSU Medical Hospital building. It will drain into the proposed pond. Basin is located at the northeast corner of the 1310 0.09 94 0.9 proposed building. This basin drains to a proposed area inlet. This basin is located east P11 0.39 43 3.5 of the building. It drains onto College. P12 0.59 38 5.2 This basin contains the proposed detention pond. This basin is located south P13 0.26 39 2.2 of the proposed building. The basin drains directly to the pond. This basin is located to the P14 0.43 51 3.9 south of the proposed building and drains to Pros ect. The intersection of College and Prospect contains an existing undersized storm sewer system. The existing intersection floods during nuisance flooding events. The proposed project will reduce the total storm flow to the intersection. Below is a summary of the offsite flow conditions during a 100-year event: • Storm Flow To Prospect: o Existing conditions = 20.5 cfs o Proposed Project = 3.9 cfs. • Storm Flow To Lake Street: o Existing conditions = 6.4 cfs o Proposed Project = 1.6 cfs o Proposed Inlets collecting flow off of Lake Street = 5.2 cfs • Storm Flow To College Avenue: o Existing conditions = 8.8 cfs o Proposed Project = 3.5 cfs o Proposed Inlets collecting flow off of College Avenue = 3.6 cfs The proposed project will discharge approximately 16 cfs less than in existing conditions onto Prospect, approximately 5 cfs less onto Lake Street, and approximately 5 cfs less onto College Avenue. Page 3 of 4 The proposed project will collect additional flow off of Lake Street and College Avenue to reduce the total amount of flow draining offsite form the proposed project. The proposed project collects an additional 5 cfs off of Lake Street and 4 cfs off of College Avenue. CSU Medical Center — Proposed Detention Pond: The proposed detention pond was analyzed in EPASWMM version 5.1.009 and will have the following properties: • Invert Elevation: 4991 • 100-year Required Volume: 0.7 ac-ft • 100-year Water Surface Elevation: 4995.94 ft • Top of Pond: 4997.0 ft • Orifice size: 20-inch dia • Flow Out in a 100-year Event: 10.8 cfs CSU Medical Center — Proposed Storm Sewer System: The proposed storm sewer system was analyzed in EPASWMM version 5.1.009. The proposed inlets were analyzed using the LID Inlet spreadsheet. The proposed EPASWMM model and inlet calculations are attached to the back of the memo. Refer to the drainage plans for the size and location of the proposed storm sewer pipes and inlets. Summary: The proposed project meets the requirements of the Mason Street Outfall design and discharges less than existing conditions to the intersection of College and Prospect. Additional inlets were also added along Lake Street and College Avenue in order to collect offsite flow to further reduce the storm drainage to the intersection. Page 4 of 4 No Text kn Q) — M O � r r 00 �o r �o 0 0 0U d 'ct N 00 V o0 O 00 O w N M D '. 7 U CG 0 0 0 N m o I o 0 0 0 0 0 °c � o l� N T 00 QN M 00 to It V1 N N N N (V N O 0 C o c " 0000 r- �o M O O O O O O O O O O O O a Q. C_ E-� W O O O O O O 0 0 0 0 0 0 c m o c E• � M M M M M M a s tj ro N rn m a Proposed Conditions N c 0 0 U N N 0 0. 0 L a i r.+ C U _V 4) 2 U 00 00 M � w t- M M 0000 � N � � Q\ I- oo D\ D\ h c� O\ ON 01 00 1— r 00 O O O O O O O O O O O O O O �U a; 00 n �c kn O �o r- N O Q\ V W1 kn k O M N O M N M 00 O f+1 to N M ~ a r-v N N O M N M 00 M N M O O O O C O G C O C O O O C oc O O \10 �b N �o (O\ 00 n O v'1 Ln N �o M 0o N 7 M N �o N O N 00 N 00 O\ (7\ M N M M M N M M cl1 K1 M N N N ca O c O c F � O O 1- [, 00 v) r- O O O M oo N N O N O O 00 O 00 00 �o G O O O O C O C O C O O C C Y F° S O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O C O O O O O O C O C O O i > c O S O O O O O O O O O S CDC C C O G C O C C O O O C O C G ce o c F a M M M M M M M M M f+1 M M M M d F� a CC G O rl- O 00 O a) a a y p nro p A A A A A A W N o o w c w G7 Gd W N > v %-. _v o cai C 0 0 0 0 0 0 o o o 0 0 r r r z z z z z z z z z z z � � o O O N N w w O O O O W C� � OJo c7N J C� m �c v� A O O . W N N N N W W W W W A \O A O O O O O `O A c.n W O J Cn 00 00 J O N i A Oo N A 00 ,max A A A A A A A A A A A A A LA O O to In J ON O\ J J D\ D1 D\ l.n In A O O O A oo J O A oo J O, O a, IA � � d CD O O O O O O O O O O O O O O O � o v _ co .. w O O O N A A A A A A A .. A .. c.n .. In N y 7 dCD 7y b o 3. CaD �D A O O O O O �D A prpy. A 00 W lJ N .- vi W N ll� tli to 00 N ? ao a CD 0 CD 'O S C/1 C CA M l- �O N N l� 00 O N O ^-� O N �o O O V t- 00 m N N M O O 8 pQ m v1 en m O O O O o � b M V v� vri N N 7 CN � M 7 m N N N V1 O M �o �O cM N O M It ON p Ln O O en i7 r�i O C 00 O C '. p can O O O can O G N O C Cl)O� O C O O O O O E Epp a� p << O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o E o Fr W) �o V v'l N --� 00 �O O \D 'cY w 00 �O 7 �o n Vl O 0o Wi (0 a\ 00 v'1 E N N O O vl v'i rM �6 \O Cl) N O M M p F U to �O N v') N O O vl 00 h C ON vi kn O O 7 to O N zr M V N C O M O N M N O M M M E O LL I; r. u z z z z z z z z z z z 0 0 0 0 0 0 0 0 0 0 0 Q H H u H u u u U u x Tu 0 0 M. 14 p .+ N z G y U a N N ti .; -N ti ti ti ti y ti ti a H U a a T Z cn 0 0 " 4. p. p. A w K) �. a a a ro ro N W a � °z z z z m zz z z z z zz �x S G cn �n O O O O O O O O �n ctl0o w A O O O w W A 00 oo A O O 00 n O w W a �aC o f ° _ CD A A ON J O w w oo O cn O �lCD N �l v �- O E O O N �A LA A O WOO A O O S O �O A w --1 to O u, w Oo W A U) C CL D) m m rt (D O 10 c� a 0 3 Q. N M o a E g 0 0 0 o E 0 T. 0 Q /.y N 3 r U � cO a rn � M 4Qp" � O o O M O 0 �N w g o w �a a � o � a rn a Qa N M L S � Jo > 1 O o� a � c a° OV O 0 y O F � c 3 60 0 O N cq enM O O O 7 � 00 L o M M � � U N VNj cn r It O O 0U 06 M 06 M o Nt 3 c c O N U " z Y y Zo � �o a C) F U t6 N ° a a A w nri r a o oNc bo � b a _r N O C X n n n n n n n n n n n d d d dCD m 0 O to Oo A w .A O twit ///--- w d O � 0 0 0 0 0 0 0 0 0 0 0 0 �x � x• °c 0 0 0 0 0 0 0 0 0 0 0 o o � f °O•n N � � a _ O A w C\ CN \o D\ A cUn � C � O k O O O O O O O O O O O N A A 00 W �O W \O ? --1 v W T LA W CD G O O O 1 O O O O CoilO O O r E S 0$ S 0 S 0 S S S 0 o 0 0 0 0 0 0 0 0 0 0 C y V c U A 0 S S o S S o S 0 o S 0 0 0 0 0 0 0 0 0 0 0 U a+ �U 0 o c c o 0 0 0 0 0 0 L .V. 7 v7 U V O\ 00 ON N O� 00 O\ 00 O\ 00 O\ 00 O\ 00 T \o O\ m O\ 7 01 O O O O O O O O O O O A •� � U 0 S S S 0$ S 0 COO o 0 o d o 0 0 0 0 o d cG ` L �A A S o S S o 0 0 0 S 0 S 0 0 0 0 0 0 0 0 0 0 0 L aA C C O O C C O C O O O O O O C O O C O C O O T � �A w 00000000 CD 000 g c � U Q Q a.+ a a s n 3 a coCD a vi y b y y 9 0 oo oc O b O� a C ri t' ny p 0 g 0 0 o 0 w 0 o 0 0 0 0 000 0 0 0 o o a 4 ^ 0 rn 0 o 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0— 0 0 w 0 m i i n N C cD CL A w n CD .-w m O .a O co <D Q n O 3 Q O 3 N E A 0 0 0 0 0 0 0 0 0 0 0 T Vj 4A O O O O O O O O O O O U 0 0 0 0 0 0 0 0 0 0 0 0 o c o 0 0 0 0 0 0 0 � � 3 ° Qz '/1 V1 V� 00 W) W) 00 DD 00 N V'I M O v� kn kr, O O O O C O v N x� ca M O 00 M O O O 7 x� M W� �c O 0000 M O O O vi O C O O O C O C kn H C o W ti xt ° ca 4.1 �I ri VN cn N O �i 3 Project: CSU Medical Center LOCATION: Parking lot COFC Area Inlet = C„ A, V2 X H Co = 0.65 Inlet Length = 1.484 Inlet Width = 1.016 # of Inlets = 1 Ao (ft2) = 1.508 g = 32.2 COFC Area Inlet Notes Elevation Head Orifice Flow feet cfs Invert 1000.00 0.00 0.00 6" Ponding 1000.50 0.50 4.45 18" Ponding 1001.50 1.50 7.70 I 1 Project: CSU Medical Center LOCATION: Parking lot COFC Area Inlet Co = 0.65 Inlet Length = 1.484 Inlet Width = 1.016 # of Inlets = 2 A. (ft2) = 3.015 g = 32.2 COFC Area Inlet Notes Elevation Mead Orifice Flow feet cfs Invert 1000.00 0.00 0.00 6" Pondin 1000.50 0.50 8.90 18" Ponding 1001.50 1.50 15.41 Project: CSU Medical Center LOCATION: Parking lot COFC Area Inlet Q Q,,,e,,. = C„A„ V2gH C. = 0.65 Inlet Length = 1.484 Inlet Width = 1.016 # of Inlets = 3 A. (ft2) = 4.523 g = 32.2 COFC Area Inlet Notes Elevation Head Orifice Flow feet cfs Invert 1000.00 0.00 0.00 6" Ponding 1000.50 0.50 13.35 18" Ponding 1001.50 1.50 23.11 INLET ON A CONTINUOUS GRADE R1PIWr. csu McCleel CeMeT Inlet 10: Type R p8M DLO Icl—w N.Oee lFVaR Nb W G Oai al.aIlInlil MINOR "OR IYw onnNl TV" =Dupe C010OWW0 L..w:ni Uuwuwiun laWWmlulmconnluwin yNl.l egllemun %'Imn'OAYOWI A_ 3.0 IIIMr [alai NwWIPIUN%MIMIN.O.I>nl CaMOWnpl Ma I Liai0 a 91.0. untl INN 'ON'. PI 10WW01 L. 5.W 0 W. oI a UM O ne IaIImI W pAAN' ll W 1. Owowl W,. µA bgylnp FaCln Ip.511pb UM OMe(Iyplml min vtluee0.51 C-O WN WA g , Fai 1.. Snaln Uaa Cal OWW1011yl. liNni.0.11 CrC 0,10 0.10 Anal evlmum MINOR "OR T.1.1 Ialao, NaruPllon Cape[IIY 0 2.13 2.40 T.1.1I.lm Ce111...... oypwaln0lnlary Or 0.e 1.6 . C."un Pe..i. OJq,. C% T tl JD-Il e3 14Ty0e 8 I0MI5 AII., INOI On Greve 7 3 15.8-.10 AM into IC INLET IN A SUMP OR SAG LOCATION CSU Me0lcal Center Lp ICI N.Curo WP N-Vet wo w Lo Of JM1an InlOmetlon Region fi lol Ines, Inlnl T,,n .pcM Dereasalon taee11ans1 to c.AWA , on. gnPneu,on'e NOm G Al. I uw.� lumbar of UN, W. IGrPIe of Curo Opemngl No Noun Depin e1 Flonlun foWlOe of t.1 Eepresslml Pane, OIpN 3.Inflarr n .enem ale Una Grate i—Of NIQ11018 Unn Grain W. rue Opening Rnlln,m n Grnln (npin, values 0.150 W) Ati ;logglnp Fectbl for a Single Gran (lryka) vaWn 0.50 OJU) C,(G) 3n1B Weu COelllcionl llypkul vMue 2JS 3.60) C. IGI irnM Gnike cann)uMll twlfnl valln a.eo 0.110) 0.IS) gur! Opening Inlprmalle r nnpm or n NM turn r"no", I. 161 iggnl W VMcel CNb Opi nlry an IMI1m Nam. 1B10M M Core am[a TNaa, In ITIm N.— "Is of Tbroel (see USDOM Figure ST.S) Tlala in, Width I., U,,enelan Pon llNlcolly go, outlor wletn a121ebp W. ;lugpllg Faclu lu a Se-& Curb Op.N IW .l valor 010) C. Cl :u%OPsrvnO Wan Catllgnm W .M wlua 133.1) C. ICI :�Pn Gpewg OIIIY.n frWlkwnl lFpeal VBIw C fin - 0 )ni rotal Inlet Interceptor, CapacRy (mom ulnas cloggatl condition) 41 nwl C.Ae IS GOOD for Minor ale MNm Stoma UO PFANI Or... —. MINOR MAJOR f.00t T,. R Coro Donne, 9.00 S'S brunee 5 rcrea MA1oR � 14n1e WA NrA N/A NIA NIA NIA NIA MINOR MAOR 5.03 6,00 6,00 61,a0 1A 0.10 0,10 300 0.6] U6,nnl, v3 14 Type R Inlees.oWnn, Ii lal In Sump T30,2015. 0.12 AM ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) 11 Project: Inlet ID: Gutter Georni fiEntar [late In Me blue Maximum Allowable Width for Spread Behind Curb Taece = 10.0 a Side Slope Behind Curb (leave blank for no conveyance credit behind curb) Ssncx = 6.002 In Manning's Roughness Behind Curb (typically between 0.012 and 0.020) %A.c = 0Dia Height of Curb at Gutter Flow Line Hcvna = BAO inches Distance from Curb Face to Street Crown T.o = 20.0 it Guter Widih W 1.50 k Street Transverse Slope S. = 0.020 ar11 Dollar Cross Slope (typically 2Inches over 24 inches or 0.083In) SW = 0.003 OBI Street Longitudinal Slope Enter 0 for sump condhlan So- 0.010 form Manning's Roughness for Street Section (typically between 0.012 end 0.020) nsxssr 0.016 Minor Stonin Major Storm Max. Allowable Spread for Minor & Major Storm Ta,w = 18.0 1a.0 h Max. Allowable Depth at Gabor Flowllns for Minor & Malor Storm daxx 6.0 B.0 jinches Allow Flow Depth at Street Crown (leave blank for no) C 0 check=yes MINOR STORM Allowable Capacity is based on Started Criterion Minor Storm Major Slorm MAJOR STORM Allowable Ctubacay is based on Stand Crtterlona.,.. 12.1 f2.1 ble Minor storm Max. allowable capacity GOOD - greeter than flow given on ehnt'O-Peek' Major storm max. Allowable capacity GOOD - greater then flow given on sheret'0-Peek' UD-Inlet_v3 14Type R Inlets.xlson. O-Allow 7/3012015. 8:12 AM 1 CTLITHOMPSON ' GEOTECHNICAL INVESTIGATION , PROPOSED MEDICAL CENTER COLORADO STATE UNIVERSITY FORT COLLINS, COLORADO t COLORADO STATE UNIVERSITY 251 Edison, 6030 Campus Delivery ' Fort Collins, Colorado 80526-6030 Attention: Mr. Milt Brown ' Project Manager Project No. FC07034-125 ' August 18, 2015 ' 1 400 North Link Lane Fort Collins, Colorado 80524 Telephone:970-206-9455 Fax:970-206-9441 ' TABLE OF CONTENTS ' SCOPE 1 SUMMARY OF CONCLUSIONS 1 ' SITE CONDITIONS AND PROPOSED CONSTRUCTION 2 INVESTIGATION 3 ' SUBSURFACE CONDITIONS 3 SITE DEVELOPMENT 4 ' Fill Placement 4 Excavations 6 ' FOUNDATIONS 6 Spread Footings with Minimum Deadload 6 Drilled Piers Bottomed in Bedrock 7 ' Laterally Loaded Piers 8 Closely Spaced Pier Reduction Factors 9 BELOW GRADE AREAS 10 ' FLOOR SYSTEMS 10 ' PAVEMENTS 13 Pavement Selection 14 Subgrade and Pavement Materials and Construction 14 ' Pavement Maintenance 14 WATER-SOLUBLE SULFATES 15 SURFACE DRAINAGE 16 FIGURE 1 — LOCATIONS OF EXPLORATORY BORINGS FIGURES 2 THROUGH 4 — SUMMARY LOGS OF EXPLORATORY BORINGS APPENDIX A — RESULTS OF LABORATORY TESTING APPENDIX B — SAMPLE SITE GRADING SPECIFICATIONS APPENDIX C — PAVEMENT CONSTRUCTION RECOMMENDATIONS APPENDIX D — PAVEMENT MAINTENANCE PROGRAM COLORADO STATE UNIVERSITY CSU MEDICAL CENTER CTL IT PROJECT NO. FC07034-125 T I SCOPE This report presents the results of our Geotechnical Investigation for the proposed Colorado State University Medical Center in Fort Collins, Colorado. The purpose of the investigation was to evaluate the subsurface conditions and provide foundation recommendations and geotechnical design criteria for the pro- ject. The scope was described in our Service Agreement (FC-15-0245, dated July 8, 2015). The report was prepared from data developed during field exploration, la- boratory testing, engineering analysis and experience with similar conditions. The report includes a description of subsurface conditions found in our explora- tory borings and discussions of site development as influenced by geotechnical considerations. Our opinions and recommendations regarding design criteria and construction details for site development, foundations, floor systems, slabs - on -grade, pavements and drainage are provided. If the proposed construction changes, we should be requested to review our recommendations. Our conclu- sions are summarized in the following paragraphs. SUMMARY OF CONCLUSIONS In general, soils encountered in our borings consisted of sandy clay. A layer of gravelly sand was encountered in three of our bor- ings below and/or within the clay layer. Sandstone bedrock was encountered in eight of our borings at depths of 18 to 24 feet to the depths explored. 2. Groundwater was encountered in eight borings at depths of 12 to 19 feet during drilling and 11 to 161/2 feet when measured several days later. Existing groundwater levels are not expected to signifi- cantly affect the proposed construction, but may affect drilled pier installation. 3. Existing fill was encountered in our borings. Several structures were still located on the site that will be demolished prior to con- COLORADO STATE UNIVERSITY CSU MEDICAL CENTER CTL IT PROJECT NO. FC07034-125 ' struction. All structures should be completely removed below im- provements. The existing fill should be completely removed and re - compacted below the proposed building. ' 4. We believe the proposed structure can be constructed on spread footing foundations with a minimum dead load placed on natural, ' undisturbed soil and/or properly compacted fill or a drilled pier foun- dation bottomed into bedrock. Foundation design and construction recommendations are presented in this report. ' 5. The presence of expansive soils and bedrock constitutes a geologic hazard. There is risk that slabs -on -grade and foundations will ' heave or settle and be damaged. We believe the recommendations presented in this report will help to control risk of damage; they will not eliminate that risk. Slabs -on -grade and, in some instances, ' foundations may be damaged. 6. We believe a slab -on -grade floor is appropriate for this site. Some ' movement of slab -on -grade floors should be anticipated. We ex- pect movements will be minor, on the order of 1 inch or less. If movement cannot be tolerated, structural floors should be consid- ered. 7. Pavement areas including parking and access drives are planned for this project. Four borings were drilled in the area of the pro- posed pavements. Pavement section recommendations are in- cluded in this report. ' SITE CONDITIONS AND PROPOSED CONSTRUCTION The site is located northwest of Prospect Road and College Avenue in Fort Collins, Colorado (Figure 1). Several vacant residences are located at the site that are to be demolished. We understand the proposed construction will in- clude a new Medical Center. The 4-story Medical Center will be approximately 120,000 square feet. Associated pavement areas will included parking and ac- cess drives. COLORADO STATE UNIVERSITY .L CSU MEDICAL CENTER CTLIT PROJECT NO. FC07034-125 :f' !a�} tl �ia°'�% ! �_ apQ�estlf �!l�ft g° 3¢a !t' 9 1 afrze !`!' !q�•CCaa ! { d € q!q 1P; - g !11 i ,pp, ppay 9g9p €� �� [it fxeil i� fe It !x! •!y9° y `f �i• �fE �i 8 I7 6!f!8! x1!lfia Ip y� ! fi 1Sl�^!j!� ix !t� if (( it �i q°'8aa5mw if �t �Ef9 1 1i' �yysaS ' fy� ��i61�g}!`5°9d� d y d g ait S f g f !y a !!, g !g 'i € ij ,, g9le•�r l ,s c 'la !fit 1.1 1!! �lxr1 .al111.4 ,!e a = Mill cs I13of, r ! �pga�l [ i R i C 6 SR•�!!ii fill[te illi'Str! a!! Ill will (!lii No Text O V m j m 0) N off V � m W m O m N c Q O N N m o 0 0^ W Emu,. m O l NIL d LL Q CA C y 10 A a o doe Y tq u° 01 JVA Incorporated Job Name: CSU Medical Center 25 Old Town Square Job Number: 2487c Fort Collins, CO 80524 Date: 1119/16 Ph: 970.225A099 By: LAT Fax 970.225.6923 CSU Medical Center Historic Runoff Coefficient & Time of Concentration SWMM Result Summary from Ayres Associates SWMM Model Location: Fart Collins Major Design Storm: 100 Soil Type: CID Basin Name OutletTotal Area (ace) Runoff Coeffs Flow Rate (cfs) E7 LakeSt 0.92 0.76 6A E2 College 1.13 0.80 8.8 E3 Traintiacks 0.67 0.81 6.1 E4 Trai uracks 0.34 0.64 2.8 E5 prospect 1.86 0.71 13.8 E6 Prospect 0.89 0.69 6.7 TOTAL SITE 5.81 0.74 44.7 2487c - Rational Calculations 2016DI 18.xlsx Historic -Results Summary Page 1 of 1 �c V1 r 01 N r M v O N O r r 00 oo \0 r �c kt� o 0 0 0 0 0 o 0 zU a oc - r, oc � �O 00 �O N K1 �6 o N 7 U a� r O O, O Vl O N O M �O O W d O < � � O n ON It'ITN 00 N N N N N O O ❑_ O � F" R: 00 r 00 F� O O O O O O O O O O O O O O O O O O � � ti LY r W O O O O O O O O O O O O rY r M M M M M M y O y C E X U to U r JVA Incorporated 25 Old Town Square Fort Collins, CO 80524 Ph: 970.225.9099 Fax: 970,225.6923 CSU Medical Center Developed Percent Impervious Calculations Location: Fort Collins Major Design Slorm: 000 Sail Type: c/o Jab Name: CSU Medical Center Job Number: 2487c Date: 1/19116 By: LAT 1 (%) = 1100% 100 % 90% 40% 10 % 0% Basin Name Design Point • yavad (sf) c(5f) A4nveatc one (sf) ^ ^roel (sf) • Q gravM (sf) Aplygn4 (sf) Alor pe (C/o anal (si) ATalai (sf) ATolal lac) Imp (%) 01 1 4.973 1.024 5,997 0.14 100.0% D2 2 7,223 5.848 1 304 4.521 17,896 0.41 74.6% D� 3 23.514 6,340 375 11.661 41,890 0.96 72.1% - 4 4,659 3,553 2221 10,433 0.24 78.7% D5 5 8,577 3,371 1,832 13,780 0.32 86.7% D6 6 7.255 18.900 26,155 0.60 27.7% 07 7 5,128 7,783 5,796 18,707 0.43 69.0% D8 8 195 3,964 10,171 14,330 0.33 29.0% -74 9 2,655 315 2,974 0.07 89A% '3 10 12.164 2,090 981 15.235 0.35 93.6% oil 11 4,530 4,470 8.152 17,152 0.39 49.9% 12 1,920 7,391 9,311 0.21 20.6% 13 13 2,814 62C 3,434 0.08 81.9% D14 14 3,486 3.394 61880 0.16 50.7% 15 15 1,428 944 2,372 0.05 60.2% SDI SDI 5480 5,880 0.13 90.0% SD2 SD2 5,749 5,749 0.13 90.0% -:D3 SD3 8,451 8,451 0.19 90.0% S05 S05 3.241 3,241 0.07 90.0% SD6 SD6 3,824 3,824 0.09 90.0% SD7 SD7 8.297 8,297 0.19 90.0 % SD9 SOB 1,802 1,802 0.04 90.0% SD10 S05 2.303 2,303 0.05 90.0% .I SDIO 1.728 1,728 0.04 90.0% TOTAL SITE 66.433 58,065 46,424 0 0 76,899 247,821 5.69 67.1% YBASIN N/A 4,356,000 1 100.00 100.0% 2487c - Rational Calculations 20160118.xisx Developed Impery Calcs Page 1 of 1 § §§f§ |}k§§ 2 |;»0M # \\})} (r { L IN ON HIM2 g f ■1 .. .. IVA- > v) JVA Incorporated Job Name: CSU Medical Center 25 Old Town Square Job Number: 2487c Fort Collins, CO 80524 Date: 1/19/16 Ph: 970.225.9099 By: LAT Fax: 970.225.6923 CSU Medical Center Developed Runoff Coefficient & Time of Concentration SWMM Result Summary Location: Fort Collins Major Design Storm: 100 Soil Type: I C/D Subbasin ID Outlet Design Point Area (acre) Runoff CoefPs C100 Flow Rates (cfs) 0100 NOTES D1 CIA 1 0.14 0.98 1.32 To Lake Captured 02 C2A 2 0.41 0.89 3.56 To Lake Captured E3 C3A 3 0.96 0.88 8.91 D4 C4A 4 0.24 0.91 2.36 E5 C5A 5 0.32 0.93 3.15 D6 POND 6 0.60 0.72 4.67 Detention Pond 07 Prospect 7 0.43 0.86 3.62 To Prospect Not Captured 08 College 8 0.33 1 0.70 1.81 To College Not Captured 09 C3C 9 0.07 0.94 0.69 D10 C1B 10 0.35 0.96 3.47 D11 C2B 11 0.39 0.78 2.66 To College Captured 012 C1C 12 0.21 0.69 1.51 013 C2C 13 0.08 0.92 0.77 D14 CID 14 0.16 0.80 1.28 D15 Lake 15 0.05 0.84 0.46 To Lake Captured by Exist Inlets SDI RD10 SDI 0.13 1 0.95 1.30 SD2 RD9 SD2 0.13 0.95 1.30 SD3 RD7 SD3 0.19 0.95 1.89 SD5 RD5 SOS 0.07 0.95 0.70 SO6 RD3 SD6 0.09 0.95 0.90 S57 RD1 SD7 0.19 0.95 1.90 SD9 RD8 S09 0.04 0.95 0.40 SDIO RD4 SD10 0.05 0.95 0.50 SDI1 RD2 SD11 0.04 0.95 0.40 DUMMYBASIN C2B N/A 100 0.48 46.32 Connected to College Inlet C28 to represent restricted flow Into system (peak flow allowable 3.43cfs TOTAL 5.69 49.53 Does not include DUMMYBASIN weigmeo Kunorr uoemciem U.00 Location Site Offsite Flows Not Captured cfs Site Offsite Flows Captured Ws) Basins Used For Calcs Lake Street 2.70 5.34 DI, D2, D15 College Avenue 1.81 3.43 D8 Prospect 3.62 0.00 D7 Total 8.13 8.77 Ii 01 l— 00 Vl N 00 ON l- .-. 00 O1 O -It �O 00 ,--i 00 r` O 7 M O N 7 �O 00 O1 cn V l— V rn rn a r oc Oo 00 O, rn r` 00 �o rn rn w o 0 6 6 0 6 6 6 6 o c o 6 6 6 6 0 0 0 �U R' N M l— V �O �O v1 r r` 00 N �c V' r Ln O� M 1, lO N �O 00 C1 �o O M M N 00 N M P, a, O M O M O O O O O O O 00 O N O M O O O N O --i O --� O O O O O O O Cl O O O O O O O O O Y O < a O D\ V1 N V'1 r` OO 7 V1 �o M Cl) O\ 00 O Wn N M N M M M ct 7 lO t` � �c h �o t` M M N N M N M M M M M N M N rr) M N O C O � F � O 01 �c N V'1 O l- V) Wn �O M O1 M O\ N 00 --� O v1 0\ O 7 --: M O O O --� O O O O O O O O •--� O O co w .° O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O r r 0 O O O O O O O O O O O O O C O O O O O O O O O C O O O O O O O O O O O O O O O O O O O O O Cl O O F M M M rK M M M M M M M M M M M M r o � F p, a E U Y cc V _ A O_ A . A . A . A . A kn 'r A N A ce) A V A kn lO t` a0 01 --+ Q A A A A A c CL a .- H h � C7 C7 C7 C7 C7 C7 C7 C7 c w � a � o w w w w w w w w w � o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 c 0 o 0 c 0 o 0 0 0 o _ � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 � o 5' Rn o O o O O O O o O o w w w w w w w w � y �l J A J ? v A v A J A J . J A J A J .- O O � R a 0 w w J A o 0 o O o O o o w 60 0 0 0 0 0 N 0 0 0 '17 C � u o x V] A `.h O O w N A O O o O O ao �o w O A O v O O N � O O O 0o A A A A A A 4, A A C� CN J J A � ;gu »° /j \ 2 0 %§N * .§ 0 /]> )� kn §22 E @ j .E E-o \)\ £ e); � a )7§ cq 2 § }\@ ~ )5 \ \ 0 � a 3 N 4 ii ii G7 O U A W � W N N N . . o� a a z z z H c� O O O O O O O O O O O O O O O O z z z z z Z z z z Z z z Z z Z z C7 a CD w :: ;Y ago W A W N N W w N w N A N N A w J U A U Oo 00 O 00 .- �c O1 O� U T .- N In O D\ N N U C7 w CD C b CD A in A w w w A N w w w w N J . O\ DO N l0 O A ; �D O U C1 Q\ U �c l0 .- 0o N �O J N W A A A A A A A A A A A A A A A A n r 41 ON 01 4, a, 01 01 01 01 C� J a, Oo 01 a, a, A w W U N U A U W O Do CD •�. O O O O O O O O O O O O O O O O x � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o O o 0 0 o O o 0 0 Ul in U w win in w A w N ? w Ln in A 0 0 �c �c o �o �c �o 00 �o �c �o Ii IV 0) 0) cc a a a o, 00 00 o O -+ a rn a O rn \0 rn 00 M M M M M to Vl kn V'1 M M M M Cl) M M O O O O O O O O O O O O O O O O O O 0 x� 0 0 0 0 o O O o 0 0 0 0 0 0 o O o A� M M O 0, 7 Ln V M N_ W) l O N Rn [� N �O . . . . O 00 � r 0, N �O �O �6 l-: t� �O ,0 �O �6 l� l-� �O �0 00 00 D1 a Ci ON 01 a C, C, C, o, C� rn 0, C, 01 Cl 0\ a 0, rn C, a C, a Cl o, C� o, C� rn C1 rn (3� rn a � x Vl C1 7 00 N t, Vl �O l- vl Vl l- W) �O l- �O M �O l- o0 ob �0 C� R It r- O Ci -• ob .-. 0, ., M -N N N N 7 M 7 Vl V N M N 7 N 7 N Y � Ll --� V * 7 I- Cl C, n W O 7 kf) �O N M C\ V1 ,O Vl r- N 00 O to 00 Vl V kn r- N 00 M N •--� - O M N V 7 N O N O O bbb Y y O (L) W is z z z z z z z z z z z z z z z z z 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 y H U H U H U F U F U F U F U H U H U H U F U F U F U F U H U H U H U MI b 0 z �-• kn �o 00 _rr AN /M �t 'n [A- ooc rr-, tea) o 0 C7 � C7 x ol� coo CD OQ o CD a CD da CD w CD CD U O U O O O rn O O O O -1 CDw O O 00CD y w k CD ? C O� O U CN O o0 O O A N O W O O U A A A � O VI O O �o L O O O O iwC W � O � � M O O O O O O O O O O O O O U O O O O W O O O O ao W o 3 0 o 0 O 0 0 o 0 O 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O Q) �wA r- V 00 7 O\ to M M O 00 --i \D Ln V O 00 O O O O O O O M N O O O O O O 3 � w w Q\ Qi oo 01 N Vl m en\0 M l- 1- � O M C M M M N m 1— M M N O M M M N m W X co ON M C7, M O 7 O 7 O V [— M \D M 00 N Q\ M C1 M Q\ M O O 01 M O\ M 00 M 00 M o E 3 O 0 O O O o O 0 O 0 O 0 O 0 O 0 O 0 O o O O O o O o O O O o O 0 E o o ;� w x � 0 0 o O o 0 0 0 0 0 0 O o o O o 0 0 co A x w od to M O O 00 l— 00 00 M M M enM O 7 O O\ O 00 O N O\ O M O \D l— [— Vl M O\ N M N y 3 w o k U �w i z z z z z z z z z z z z z z z z E O O O O O O O O O O O O O O O O U U U U U U V U U U U U U U U U C_ � h M N Q N9� O U m m M a r H 3 N 3 N r d r 6 r r W U `O c� Oro T c� xl r A a N n W d d o o w A W N Oo 0 o' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 z z z z z z z z z z z z z z z z d d d d d d d d d d d d d d d d C C C C C C C C C C C C C C C C C H H H H H H H H H H H H H H H H H o � 0 0 0 o k.n W o o J o oo A '— cn w C X d � M O O O O O O O O O O O O O O O O O y k O � C O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O C M w w w w w W w w w w w w w 00 .. A O w %O W 00 w J � X y n. W O oo In ON 00 O\ �c J W 0o A Oo O J W W N 6� J N A 61 �D � c w � � X O O O O O O O O O O O O W J -.4 J J O uD W to �D to �O to N O W O W O Oo A 00 LO LA � Q � A J N 00 N � 7 � 7 O O O O O O O O O Cl O Cl o O O Cl O O O O O O O O O O O O O O O O O O `; co 0 0 K r a)�wA 0 v N Y U N .X O G - M �/1 o 3 0 0 E o o c w x� 0 0 � � o o w � U � A w � � O a p Q o .a a JVA Incorporated Jab Name: CSU Medical Center 25 Old Town Square Job Number: 2487c Fort Collins, CO 80524 Date: 1/19/16 Ph:970.225.9099 By: LAT Fax: 970.225.6923 CSU Medical Center Water Quality Capture Volume (WQCV) Calculations (UDFCD Volume 3 Chapter 3) Location: Fort Collins Major Design Storm: 100 Soil Type: CID WQCV=a((0.9113}(1.1912)+(0.781)) Where: WQCV = Water Quality Capture Volume (watershed inches) a = Drain Time Coefficient (see table below ) I = Imperviousness (%/100) Drainage Time (hrs) Coefficient, a 12 0.8 24 0.9 40 1.00 WQCV North Basin: a= 1.00 1= 0.671 WQCV= 0.260 V,q,,;,d=( WQCV/12)'A'43560 WQCV= 0.260 A = 5.69 Vreyu;red = 5373 0.123 %/100 watershed inches watershed inches acre cf acre-ft JVA Incorporated 25 Old Town Square Fort Collins, CO 80524 Ph: 970.225.9099 Fax: 970.225.6923 POND VOLUME CALCULATIONS - STAGE / STORAGE Pond Volume = Pnsmoidal Formula Volume Equation = (A1+A2+SORT(A1•A2)•D/3 Stage / Stem.. Input Tahle Job Name: CSU Medical Center Job Number: 2487c Date: 1/19/16 By: LAT ELEVATION It DEPTH(D) 0 AREA (All ft, WEIGHTED AVG AREA(A2) fl ft3 INCREMENTAL VOLUME CUMMULATIVE VOLUME R' CUMMULATIVE VOLUME ACRE -FT Depth It 4989.5 0.0 0 0 0 0 0.00 0.00 4990.0 0.5 380 190 63 63 0.00 0.50 4991.0 1.0 1,727 1.054 972 1.036 0.02 1.50 4992.0 1.0 3,065 2,396 2.364 3.400 0.08 2.50 4993.0 1.0 4,070 3,568 3.556 6.956 0.16 3.50 4994.0 1.0 5,121 4,596 4.585 11.541 0.26 4.50 4995.0 1.a 6,954 6,038 6,014 17.555 0.40 5.50 4996.0 1.0 10290 6,622 8,568 26,123 0.80 6.50 4997.0 1.0 13,962 12,126 T,079 38,202 O.BB 7.50 Volume Summary Table Volume (ft) Volume (ac-ft) Water Surlaoo Elevation Water Depth V100 1, er,5 << 0.635 ac-ft 4996.12 ft 6.62 ft Top of Pond �16 "u2 ct 0,877 ac-ft 4997.00 ft 7 50 N Volume Interpolation Calculations V100 Vol Elev 26122,91 4996.00 27665,00 4996.12 38202.31 4997.00 2487c- Rational Calculations 20160118.xlsx Vol Pond 20160118 Page 1 of 2 4998.0 4%7.0 2 490.0 O r a W W F 4994.0 Wj QmO LL6 499a.0 �4 We: F a9920 4"Ho 4%0 0 4999.0 JVA Incorporated Job Name: CSU Medical Center 25 Old Tcw Square Job Nunber: 2487c Fort Collins, CO 80524 Date: 1119116 Ph: 970.225.9099 By: LAT Fax: 970.225.6923 STAGE VS. STORAGE 0etem,on Pond POND VOLUME (cF) 2487c - Rational Calculations 20160118.x1sx Vol Pond 20160118 Page 2 of 2 JVA Incorporated Job Name: CSU Medical Center 25 Old Town Square Job Number: 2487c Fort Collins, CO 80524 Date: 1119/16 Ph: 970.225.9099 By: LAT Fax: 970.225.6923 CSU Medical Center Emergency Overflow Spillway Calculations Broad -Crested Weir Equation -Trapezoidal Shape where: O = Discharge (cfs) / H l s C = Weir CoeHecient Q = C'LH + C V �Ii' L = Weir Length (ft) l i H = Average Weir Head (ft) H:V =Side Slope Calculations Knowns: Side Slopes (H:V) 4.00 Desired Spillway Head 0.50 ft Weir Coefficient 3.087 Spillway Elevation 4997.00 ft 100-yr Pond Inflow 44.50 cis Calculated Spillway 38.77 ft Use Spillway Length 40 ft Spillway Depth 1.00 ft (induding 6" freeboard) Top of Berm Elevation 4998.0 ft Top of Berm Length 48.0 ft Berm Width 10.0 ft 2487c - Rational Calculations 20160118.xlsx Page 1 of 1 8/28/06 JVA Incorporated 25 Old Town Square Fort Collins, CO 80524 Ph: 970.225.9099 Fax: 970.225.6923 ORIFICE PLATE AT OUTLET PIPE WORKSHEET Orifice Plate Q=cA(2gH)A.5 C= 0.65 From SWMM: 100-yr Water Surface Elev: 6.56 It Inv Elev at Outlet Struct: 4989.50 ft Outlet Pipe at Structure: 24 in SWMM Outlet Pipe Diameter: 1.63 it Needed Area: 2.09 sf Using Area- determine Job Name: CSU Medical Center Job Number. 2487c Date: 1119/16 By. LAT Qvaoa allowable release rate: 10.89 cis Ao 2.09 sf I/611 e�*rco Apipe 3.14sf fl = A C2�c—B/ +F rs theta 2.609 red ° PWe l2 l 2 2)JI Ao-calced 2.09 sf ( l m 0.26 ft distance above(♦) or below(-) center m = I' C05 2I J H 1.26 ft Height above pipe invert H = r•+m 2487c - Rational Calculations 20160118.xlsx Restrictor Plate OUTLET Page i of 1 JVA Incorporated 25 Old Town Square Fort Collins, CO 80524 Ph: 970.225.9099 Fax: 970.225,6923 ORIFICE PLATE ON PIPE L1 B AT INLET C2B Orifice Plate O=cA(2gH)".5 C= 0.65 From Sl~ 1 00-yr Water Surface Elev: 3.82 It Inv Elev at Outlet Struct: 4993.20 It Outlet Pipe at Structure: 12 in SWMM Pipe Diameter: 0.75 R Needed Area: 0.44 sf Using Area- determine Job Name: CSU Medical Center Job Number. 2487c Date: 1/19/16 By: LAT OMa,oe allowable release rate: 3.51 cfs Ao 0.44 sf \I j�-I/ \I 1 \I B Apipe 0.79sf f1 =[APjr,('K_t' +[rsil� I*rcoBJ11theta 2.951 red° 2n 1\ 2 I\ 2 Ac-calced 0." at J( /I J 9 l m 0.05 It distance above(+) or below(-) center m = r cos 2 J H 0.55 ft Height above pipe invert H = r+m 2487c - Rational Calculations 20160118.xlsx Restrictor Plate L7 B Page 1 of 1 JVA Incorporated Job Name: CSU Medical Center 25 Old Town Square Job Number. 2487c Fort Collins, CO 80524 Date: 1/19116 Ph: 970.225.9099 By: LAT Fax: 970.225.6923 FLOW CALCULATIONS - GRATE INLET SUMP CONDITION (Reference: Urban Drainage and Flood Control District Drainage Criteria Manual, 2001, VA, Section 3.3.6) (Note: Spreadsheet assumes orifice condition for fully developed flow.) INLET TYPE: 18" Area Drain BASIN: D9 AND D13 Orifice Equation: O = Cd'Ao'(2gH)A0.5 K = Clogging Coefficent value for multiple inlets Adjust Ao (open area) due to clogging as follows: Effective Area Opening As = (1-C) Ao, where: C=K'Co/N N = Number of Inlets Co = Single Inlet Clogging Factor: Co(grate) = 0.5 (50% clogging) Number of inlets: Inlet Dimensions and Effective Open Area: Grate Oaenlna: Allowable depth: Constants: Flow Calculations: Grate Flow: N= 1 Ao(g) = 0.61 fr`2 Total Ao(g) = 0.61 ftA2 K = 1.00 C = K'Co/N = 0.50 Ae(g) a (1-C)Ao - 0.31 ftA2 H=30 in = g = 32.20 fUSA2 Cd = 0.67 Q = Cd' Ae(g)' (2g•H)Ao.5 Gg. 0.02 CFS N Grate 2 1.5 3 1.75 4 1.88 5 1.94 6 1.97 7 1.98 8 1.99 0.25 ft Total Intercepted Flow with 1 inlet(s) and an allowable depth of 3 inches is Required Flow (O C2C) = 0.77 cfs Bypass = Required Flow (O C3C) = 0.69 cfs Bypass = 0.82 cfs 0.0 cfs 0.0 cfs 2487c - Rational Calculations 20160118.xlsx 18' Area Drain(UDFCO) Page 1 of 1 AREA INLET IN A TRAPEZOIDAL GRASS -LINED CHANNEL CSU MEDICAL CENTER C1O T,•,,, Grass Tmpa Lial Mandan 's n �T, I F d M„r d z A oou e Ga c o.033 D 003 e E 0.024 fir TmmsMI Uri Llrbd CbennN Utlm=5 Me peal aided. (A. B, C, D, or E) 5 n (Leave cell ole blank b mvma4y enter an n Yals, ri.es sloop fifth 91gm sandy solos DSD Nom9onfy ]Olpa ,B. an. Allis able lop Width or Chanel for Minor B Major Stem lax. Alcweble Water Depth m Channel for Minor 8 Mohr Stood Possible Channel Caoe.RM Based IonGmxm INOR STORM Allowable CepaoltybWidth Castle. IAJOR STORM Allowable C.psiohy Ie b... it on Top Width Criterion Leto DeWh In ra Chanl Based Do Demon Peak Flow esilpn Pesik Flew mar Depth In.,.lonn mu..nowable rapaclly .000 - 5rvalor own now pwnn nn aneet'O�d..dr �elnremnn mar. atmwnnl. ropacny GOOD-ao.l.r then now mvnn nn sneer o.Pn- m pain IMmmMlen (Insult rpe of iMM rgle of Indlead Grab (moal be r. so ftes al all of Grab "In a Greta pen Ares Rho egmaamended Gom. IWOtrp Fecapb reb DieWrya CaellliYVM ' A, e, C. o or n Mrod z1Im r Ones, one: C wpm * No candy Minor at MSe in T. 13.00 13.00 wr cal.• 0.a6 0A5 real CL -1 1.50 i 1.50 .Psi d • 0.10 0.18 . lam Top. -1 Ueer.Dennef B. 0Do depreea W - m fee L= IN Ira 0.0 ' 0]D He Den bat l G• ow }' C.' NIA C • age C.- 2.05 5df� MINOR MAJOR IeIIM&OmdeardauddrMels. I lonllseobaffwfepona ) d= t Interception Capacity (aeeumea clogged condition) Q. e rrra rr ....rvr r. prop O Peek for Minor and Malor Starme Byw llaadFell- CapWm Percentage= O/0- • C1 118 018 o.0 ou 1.05 1.05 30 00 2487C - UD.Inla1 M3.14 AREA DRAIN C1C. AN., Area INet 111912016. 1:0/ PM AREA INLET IN A TRAPEZOIDAL GRASS -LINED CHANNEL CSD MEDICAL CENTER Clo T. Omen T. LNtltln Mann . n T A 0m B ON 1 d c O.WJ d 'S nM'11 D 0.03 :7 1E U.Ol4 OILTnmu Ww OrwLlmd Chwnel WhoSOSM. pMM RaIYWMe IA. B. C. D, m EI . n (L.. edl 0I6 binn41. menmlly enter Ion n vnluel oven s ope Wei slope N=sandy s.o foe D.so dy TD 1, 0.w Ian. Nlowebls Too WMIn of Channel In Minor S N.J. Slam Ia.. NlwyebM Water Oepm In Cheore for Mina a Major Strom Plowable Channel Capacity UMped On ChI GennI ANON STORM Allowable Cepeclty Is heed on Top WIMM1 Criterion iAJOR STORM Allowable Cepeclty 1. beeeE on Tap Width Crltetlon laltr Coon In Channel awed On Oeelon Peek Flow orlon Peek Flow nt"?m— a l—Arcnparny L,.OD 1-nlnr an wnl non 1'O-Peak' silt?" In- allowable<apucny 4D00 Umale, Inen Ilow Ulven on neel'p�Penk' aNen Inlwmwlon Ilnoutl I lnlnl Imp.l on -= 30 deornesl noon w Dmin pen Alen Rom N moll of InUlnw Orela IOUDina Facia ,.In Doaorga Coef oroni onno Conn.. for coamcmni A B. C. b or D.am 6n• O.m10 Illll a= 2w n 21 = 11 W z2- sm IM r aawe OM: C sally ® Non-mM y M Bbrm Mn d Slolm T.Me 10.w I to I..t III . ON I ON feet (4-1 1.30 1 1.So d. d-I 0.10 1 a.fe few IMw Types tlwnDallned 0. 6m deome. I.m law L= L Ian faro A.- a F6 am Feel G am Ce. NIA J C. . bw C.• 1115 l MINOR MI Donn el lnIn nw eepreexG inielID. I ICI a Won, 1, Geaenemm d Inlet Interception Capacity (assume clogged condition) Qn N. inu"O1-k n"MI""r nnJ M.""r 11.nn. Bypeaxtl FbW�4a C.mnrc Pemmaoe • OJD.. ell 0,19 1 0,16 om OM 0w 0.w m x 2481C - UD4nle1_v].14 AREA DRAIN C1D.A m, Arm Inlot 111W2016, 1'04 PM INLET ON A CONTINUOUS GRADE Project: CSU MEDICAL CENTER nIat ID: Cxe r—La ICl-�( Rf�b 14VM Nb W .lam Lo Ti) mlon lnrx tloo finoull MINOR MNC ype Ot I., Tyyea MOT Tyr,' RpUb Ow'n �W Omraae .W.Nnrel to wm.. Inter CepraFtlOn'e l..' WI qyp•• 3.0 analN..( Units In llm llbl(Grate or Urn OnennR N. 1 agln al a SIIWU Untlmt(Omw or CUE Opxlbg) Lr 5.00 IIOIII.1 a UNI GraIe ICan0l be" I., limn W lmm D-Abj W. WA bIW W Facbr for a Slryb UNt O (typal Inn. v • 0.5) CnO • WA NIA Intnn Capaep CanyOvx Fipw (flow III... 41,lnb0 ncenla0e • OJO� • 1497C- UO-Inlet 0.14-TYPE R 5Pf GRADE UB Am Inlm On Grade 1119120%. 1 N PM INLET IN A SUMP OR SAG LOCATION project • CSU MEOICAL CENTER InMt ID• CtA CM GA CIA. CIS —Lo IC) R.Cum M.Ven - - We Wp W \' �� Lo IGl Ne1m1 eue neeen flow ,w of Inn, INN T,, ,.I Doeneuoe ladd .. I. mnnlegl. 91eler owwwer, O-AIbw) imYer of Unl INNS (Grate or Core ONmgl No let. DwIM1 al F"-(ola6Me of Weet dwerfoionl POMog Depth: rare lof.ik n ngle of a UNI One. L„ (G) fitlN of a Ont G2Ie W. rea gronlq Ratio fore Gone (IYWWI values 0,11690) A,.,' b991n0 Fa.or fora SVgk Grab (tM.1 vein cW - 010) Or (G) rete Wnlr Coefnceni ftfewl value 2,15 -3W) C. (G)' fees Wine CoetllceN (twiefe V.nn 0.60 - 0,00) C„ IG) uN Ope19p boloweden en,te of a Une Cue ONnrg 40). wc%oI Vertlul Cole Owning In 1. Nr' NIOM o1 C.OnnN nee. In 1. H . n9M of ThN1(we USOCM FlOue ST-5) TMe- lee Wen For G norew od Pen (1,waly tie Soffer redin W 21N11 Wd b99pg Feelor fare Sniffle Cun Own, (Wn.I whom 0.10) Cr (C), uE ONNIg WNr Cow.. (W.1 vebN 2.13.7) C. (C)- on Opening 01 Ceeilbeni no%W nefe O.W 0.20) G.. (C)' 'otal Inlet Interception Capacity (assumes clogged condition) Q. ifnCw.roy, IS GGOG Im Wnor end Melon 51mme VO PEAK) a —..omen' COOT TrN R core Oonre, 300 55 5 5 InFAN MAJOR 0 ParMe Oe01as Nf INf NIA NIA NIP NIA NIA NIA NIA MINOR MAJOR S.M B 00 600 W.CO t.W 010 0.10 3130 062 NI Nee now, on. MN 2467C- UNnIc1v3. 14- TYPE R 517 SUMP Aeon, Inlet In Sump 1/1912016, 1 10 PM INLET IN A SUMP OR SAG LOCATION Pro)eat • CSU MEDICAL CENTER ml.t ID . Cur Lo (C)—i HCUN H-VM WP WO _ W Lo IG1 p•.lm MlomulNn lineup MINOR MAJOR Iypeofinat InIMType• CODTTypeRCun Qovr, Local Oepmai (fiddllionel In wMlmnls gUlW Awasolon'a' Imm'C.AMW) 9.u• 3l0 IrAnv NUneer of UNl loot (Gone or CUE opanng) No .1 1 Weser Depin of HoWlm feu.IEe of bion d"Jurnnl P.NInp Danin =1 5.0 60 I— GnaulnfmmMbn MINOR MAJOR �O's"NO �tliF Lori of a UNfGm1. L„(0)• N/A IeW With of a Von Grate Wa• N/A IeW ve OpeNrg Revo for a Gone (tyMm Aluea 0.1 W 90) A.• • NIA Cbgging Faplm fin n Soµe Grain Rypcal faun 0,W-0.70) G(G)• WA N/A Gnor Weft Coeff¢iaN nyWal vao, 2,153.W) C•(G)• N/A 3.1. Onfim CoefOUaW N'.1 After am -O.W) Cc (G)- WA unto 0p.*, 6ImnWlm MINOR MAJOR m al a um cue Gperm, L.(fa= f0.aa teat )IW6M of Vertical Cue 0porn In Imlres H_ • film Inman HegN of CUE Onfirm Thoa1 in Inman N—= film " one NMI, of TMoel (f® GSGCM Figure ST-5) Tlela- I o'. Sld. ..n for Gepeanon Pan("rJnf lm A. WNn.12 feet) We= I.W IeW Gggging F.., Inr a Singer CUe Conn, ryNnal v 0.10) C, (C)= off) 0.10 Offering Wee Coefficient ("cal Vale 2337) C•(C)• 3.W OperYg glfrce Loelllgerr lryWmlValn o.W o.]O) C. IC) • 0,87 MINOR MAJOR Total Inlet Intsnaeption Capacity )assume clogged condltlon) Q. • es e.x cis Mbt Comcay IS GOG01d mh Minor and Meer SloU G PEAK) Grw[a(yavy• B,m B9 cN 2487C - UD-Mlet_Y1. 14- T E R 10FT SUMP C3ANem. Inlet In Sump 111 W2016, 1.10 PM No Text Ave a E < W Laurel St E Laurel St Eaetdele Ci S E Plum St Or ad 4ain NOdM1 Or — Or Pennock sonnet 5 T Q� Imto" Locust St Ct _ PI VCR Dr i �' s � E Elizaoelh St - 5' University Ave Gedied st — — d - Cadield St '_St x Spum Or - - Edisondegroa Edwmds S 3ry e F rPlk.h Pitkin SI E Pilkin Sl y.Dr W 51W `"�ames q CI .- Buckeye g Bucks a y, PROJECT s St _6 t Lake R W Lake Sl E Lake St N Ofe � SheensCt E PROSPECT RD P`°'"€ see Babgm In - - _ Deinee — It Juni en In Be, Or E o Ct 5 ASI X Parker _ St B rky PI o V Aped Sheet Or Ct `vr W E u .E 1n 5 aped CI € '' Bi O' - E n durq Or Ct Stuart St m E Stuart St StuOd St S°Istic S nn Wintabe Greek S rin w o Cree4 s°r aNe e a L WaY JOna90n 0 - O0 manche Or Indian and V� Spring Park 0 V Ch ne cone Or rail H,'// m AOnd Or Sum Cir Rd ArtM1u Cifgal od Chele"d m - he Or Or Oar t Ich 6 0 - Rutgers Ave Nirkw LLJS 2n Sq Chippewa St C Ouke a Butt 6 CdumOio Rd u - • _ 4 1 V u o u °1 O S w L.t-I NOdR`ngten 0 1. _ Cornell Ave Cam0 ryW > Yale A, Q Perk.eod ',e W LlJ Ct J c r Dr } Hoamono d Ln J Centre O _ PO^derd� Q Ave It Ct Brawn t 5 U H _ Oueen a� LLI ° g Rd - Cl - $ (n Princeton PARK — Be ST r N WOOD Pdncet DRAKE ROAD Rd - LAKE Dr 0 aW Adolfson & Peterson Construction 797 VmNm 3L Aaaa. Colorado 80011 303. M37101 ]03. ]53:9251 Farr AVA SENNETT WAGNER GROOT ARCHITECTS 1301 Waeea. Suds 100 Denver. Colorado. 502D4 303. 52] . T323 303.02]. 2839 Fu OWNER'S REPRESENTATIVE CNarade StNa Universny Firchtme Mwswnem 251 Edlenl Grins Fat ColW, CO. e0523.6030 97049LSol Pnaoe 1141 T5T2. Fee CIVIL ENGINEER JVA CenaWlhq Engineers 25 Go Town Square, Ste, 200 Fed Cdllne, CO e0524 303444.1951 Desk Workshop 1390 _m— St. w. 100 Denier. CO, ROM 303.923 2616 JVA Consu mg Eglnmm 1319 3pmre St Buuber. CO, 80302 303'..1951 MECHANICALJ ELECTRICALI PLUMBING ENGINEERING ME Enter- 141 3enve Weft Parkway. Ste, 300 Golden. CO, ew01 303421.5555 Grgay Ebdrb MlI North Uncor1 Ave L°rNana. W. m53B MECHANICAL CONTRACTOR US En9ir.." Ce 1100 W. 1201h Ave p900 WeetminMer. CO. 002U 303.96<.8060 ENERGYIENWRONMENTAL Mntia4 Energy 130 W. SN A. Danes, CO, eazos 303.2781532 SPECIFICATIONS spsrsfflkserornM NNilem, Inc seen We. Nm°Onve ti... CO, 80123 303 92T.8362 CSU HEALTH AND MEDICAL CENTER 151 W. Less Street Fed Collins. CO 60524 Dale JANUARY 20. 2016 Issue Dfte NAGE REPORT Crewe By KFIB Cheeked By PAT Preset Nwnlry 150,12.00 ama Probes Number 14-023 R..e Sheet of FIGURE 1. SITE VICINITY MAP pYIW"Ji OALLE W mOZ NW ICD a E 6NNwn O Ua -w FR2 Mm WCR) bmBLBeOs C101 FYwidl j O1o0 CIA 1 0.14 ON I'm M 2 0A1 O.m 2.55 CN A 0.2a a91 2.m C55 5 am am a15 Faro A am on Am m Flmp[I 2 a" am as a C~ B am am 1.0, me B 0m O" om 10 c1e 10 am ON an D11 afi 11 a.2B 078 zee ou C+C 12 021 0m 1.51 oil ac 12 am 0m on O14 CID 14 0,18 ON I m5 lekA 15 0.05 a& 0.4 601 WIG BD1 o.t2 Om 1M Sm WO 6m 012 ON Im 9m lo! 6DJ On 00 I'm D5 6W BOG am 0.0 am DO Fm Bm O.OB 00 ON 1 O.1B OBS 1.BJ FOa eDe o.0, 0.% 0Q mo rm. BD+o om oB5 0SO Dtt Im2 Bm+ 001 00 040 ur6A6w c26 wA I 1m 0Ae Mm l0riim 6OA OBW FbF Hd OB0IOAB 11+Al 6m OaW FbwF CAplueO Icbl 0®vn Ust Fw D>ecF takA BUM Z70 5.N m, m, D15 A. "Al OAO m F 3 62 0m D2 1" 6.12 Bn LEGEND •������w mvw wwFW aIw WWYIr IBWw� wmm o nw � waBN waa w.r¢ Fti mmcav Bw[ eN. orsaana i¢aaAn . m-+B W1Wrr onrmn �B . Au eF1s AU wmmwAoN=GwCV AKM1B015 c..e.m.u.+.mc mutN� a+.Me �a�eMY�W m•Ym. �e4Y� roM 6M.m�M1nYY NyyCI�.�Y.a A10wn .mwfr elm •••raa A AaYl�rwoYwlc mom m�