Loading...
HomeMy WebLinkAboutDrainage Reports - 09/10/2015City of Fort Collins Approve Plans Approved by: Date: o L2b (s FINAL DRAINAGE AND EROSION CONTROL REPORT FOR FIRST REPLAY OF PROSPECT RIVERSIDE SUBDIVISION (RIVERSIDE STORAGE) q FINAL DRAINAGE AND EROSION, CONTROL REPORT FOR FIRST REPLAT OF PROSPECT RIVERSIDE SUBDIVISION (RIVERSIDE STORAGE) Prepared for: Wickham Gustafson E� rchitects 1449 Riverside Avenue Fort Collins, CO 80524 Prepared by: North Star Design 700 Automation Drive, Unit I Windsor, Colorado 80550 (970)686-6939 July 29, 2015 Job Number 264-10 1 1 1 North Star 1Aft., design 700 Automation Drive. Unit I Windsor, CO 80550 Phone:970-686-6939 Fax:970-686-1188 July 29, 2015 Shane Boyle City of Fort Collins Stormwater 700 Wood Street ' Fort Collins, CO 80522-0580 RE: Final Drainage and Erosion Control Report for First Replat of Prospect Riverside Subdivision (Riverside Storage) Dear Shane,. I am pleased to submit for your review and approval, this Final Drainage and Erosion Control Report for First Replat of Prospect Riverside Subdivision. I certify that this report for the drainage design was prepared in accordance with the criteria in the City of Fort Collins Storm Drainage Manual. I appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. Si erely. ..wOJKAG/`_S�.:_ Patricia Kroetch, P.E. -"'I'w1iIIIIII " It ' TABLE OF CONTENTS TABLE OF CONTENTS............................................................................................................... iii ' 1. GENERAL LOCATION AND DESCRIPTION 1.1 Location...................................................................................................................1 1.2 Description of Property ............................................................................................I ' 2. DRAINAGE BASINS AND SUB -BASINS 2.1 Major Basin Description..........................................................................................I ' 2.2 Sub -Basin Description.............................................................................................1 3. DRAINAGE DESIGN CRITERIA 3.1 Regulations..............................................................................................................2 ' 3.2 Development Criteria Reference and Constraints...................................................2 3.3 Hydrologic Criteria..................................................................................................2 3.4 Hydraulic Criteria....................................................................................................3 ' 3.5 Modifications to Criteria..........................................................................................3 4. DRAINAGE FACILITY DESIGN ' 4.1 General Concept......................................................................................................4 4.2 Specific Flow Routing.............................................................................................4 4.3 Drainage Summary..................................................................................................6 ' 5. STORMWATER MANAGEMENT CONTROLS 5.1 Written Analysis.....................................................................................................7 5.2 SWMP Contact Information ................. :................................................................. 8 ' 5.3 Identification and location of all potential pollution sources..................................9 5.4 Best Management Practices (BMP's) for Stormwater Pollution Prevention ........... 9 5.5 BMP Implementation.............................................................................................11 ' 6. CONCLUSIONS 6.1 Compliance with Standards..................................................................................14 ' 6.2 Drainage Concept..................................................................................................14 7. REFERENCES..................................................................................................................15 ' APPENDICES A Vicinity Map B Hydrologic & Hydraulic Computations ' C Detention Pond Sizing Calculations D BMP Schedule and Cost Estimate E Variance Request ' F Figures and Tables iii 1. GENERAL LOCATION AND DESCRIPTION 1.1 Location ■ This site is located on the east side of Riverside Drive north of East Prospect Road in the Southeast Quarter of Section 18, Township 7 North, Range 68 West of the Sixth Principal Meridian, in the City of Fort Collins, Larimer County, Colorado. See the Vicinity Map in Appendix A of this report. ' This project is bounded on the north by existing storage units, on the east by existing Union Pacific Railroad tracks, on the west by Riverside Drive, and on the south by ' existing Rivendell School. ' 1.2 Description of Property The entire project consists of approximately 2.2 acres. The site is currently developed, ' with areas of existing asphalt and gravel. Existing slope is to the northeast with slopes ranging from approximately 1.5% to 3%. The site currently drains into an existing swale ' located at the northeast corner of the site. Proposed development on -site will include one office building, five self -storage ' buildings, and associated drives, parking, and walks. Existing drainage patterns will not be significantly altered with this development. ' 2. DRAINAGE BASINS AND SUB -BASINS 2.1 Major Basin Description The proposed development lies within the Spring Creek Drainage Basin. Both ' stormwater detention and extended water quality detention are required in this basin. The City requirement for stormwater detention in the Spring Creek basin is a single -stage ' detention with a 100-year release rate equal to the existing 2-year runoff. 2.2 Sub -basin Description Runoff from this site currently flows to an existing swale located in the northeast comer ' of the site. From there, the runoff is conveyed in the existing swale to the north along the rear of the adjacent properties to an existing pipe under the railroad tracks. The existing 1 ' swale across the adjacent properties was determined to be a historic conveyance for this site. With the proposed drainage concept for this site, the detained runoff will continue to be released into the existing swale via an orifice plate mounted on the back wall of the ' outlet structure. 3. DRAINAGE DESIGN CRITERIA 3.1 Regulations This report was prepared to meet or exceed the "City of Fort Collins Storm Drainage Design Criteria Manual' specifications except where variances are requested as noted in Section 4.2 of this report. Where applicable, the criteria established in the "Urban Storm Drainage Criteria Manual' (UDFCD), 2001, developed by the Denver Regional Council ' of Governments, has been used. 3.2 Development Criteria Reference and Constraints The runoff from this site has been routed to conform to the requirements of the City of ' Fort Collins Stormwater Department. Both stormwater runoff detention and extended water quality detention are required for this site and are being provided by the proposed ' on -site detention pond. The release rate from the site will be equal to the existing 2-year runoff. 3.3 Hydrologic Criteria Runoff computations were prepared for the 2-year minor and 100-year major storm ' frequencies utilizing the rational method. All hydrologic calculations associated with the basins are included in Appendix B of this report. Standard Form 8 (SF-8) provides time of concentration calculations for all sub -basins. Detention volume was calculated using the runoff rate for the 2-year rainfall event with ' existing site conditions, which includes existing sections of asphalt paving and gravel. The FAA method for detention pond sizing was utilized to determine the required ' volume. Water quality volume was calculated using the method recommended in the "Urban Storm Drainage Criteria Manual". Refer to the detention calculations included in Appendix C of this report. 2 3.4 Hydraulic Criteria Hydraulic elements have been designed per City of Fort Collins standards to adequately ' convey the 100-year storm runoff from this site to the proposed detention pond. An existing drainage swale will convey the detained runoff from the site to the downstream railroad crossing. 3.5 Modifications of Criteria Three modifications to Criteria are being requested for this project. They are 1) A reduction in the freeboard for the detention pond, 2) A reduction in the required interlocking permeable pavers on site and 3) an alternative compliance for the LID requirement. Refer to Appendix E for the Variance application and supporting justifications for the variance requests. 4. DRAINAGE FACILITY DESIGN 1 4.1 General Concept The runoff from this site will flow into the parking lot and drive aisles which will be constructed using conventional materials (asphalt or concrete) and permeable interlocking pavers. The runoff from the site will either flow on the surface or enter a storm pipe via the permeable interlocking pavers or inlets. In a situation where the permeable interlocking pavements are clogged, the runoff will flow on the surface and enter the detention pond on the east side of the site. On -site runoff will also be conveyed to the detention pond via flows in LID swales along the north and south property boundaries. The detained runoff will discharge into the existing swale located at the northeast comer of the site. From there, runoff will be conveyed in the existing swale downstream to an existing railroad crossing. This existing swale may need to be cleaned out (with percussion of the downstream property owner) to ensure adequate conveyance and removal of any obstructions. 3 4.2 Specific Flow Routing With this design, the site has been broken into 8 basins which correspond with the LID feature that the basin flows to. The porous pavements areas have each been assigned a letter designation (A, B or Q and the remaining areas have been assigned a number designation (1-5). The runoff from the site will follow the historic runoff path and will flow from the west (Riverside Avenue) to the east and into the detention area. The basin are described in the following paragraphs. Basin 1-1 is located in the very northwest most portion of the site and contains only landscape area. The runoff from this basin is directed to area inlet #3. Basin 1 is located in the northmost portion of the site and contains the north most storage building and LID feature #1 which is an LID swale with an underdrain. The roof of the storage building is sloped to drain to the north and the swale is sloped to drain east and into the detention pond. Basin 2 is located in the southmost portion of the site and contains the south most storage building and LID feature #2 which is an LID swale without an underdrain. The roof of the storage building is sloped to drain to the south and the swale is sloped to drain east and into the detention pond. Basin 3 is located in the west portion of the site and contains the north half of the office building and LID feature #3 which is an LID swale without an underdrain. The roof of the office building is sloped to drain to the west and the swale is sloped to drain north and into Inlet #2. The water enters the storm system via Inlet #2 and is conveyed north and east into the detention pond. Basin 4 is located in the southwest portion of the site and contains sidewalks, landscape areas and Inlet #1. The runoff will flow to the inlet and enters the storm system which will convey the runoff north and east and into the detention pond. Basin 5 is the largest basin on site and is located in the east central portion of the site. This basin contains the remaining storage buildings and drive aisles. This basin will drain to the east and directly into the detention pond. 4 Basin A is located in the northwest portion of the site and contains only 6 parking stalls that contain porous pavers. Runoff from this basin will either enter the storm system via the porous pavers or be collected in a concrete pan and conveyed east into Basin 5. Basin B is located in the southwest portion of the site and contains the south half of the office building, sidewalks and 9 parking stalls. The parking stalls are surfaced in porous pavement. Runoff from the roof is directed east into a gutter and this gutter will convey the runoff north to a drain basin and storm pipe. This storm pipe will discharge the roof runoff into a concrete channel and directed onto the porous pavement. The underdrain in the porous pavement will collect runoff from the entire basin and convey it north and east to the detention pond. Basin C is located in the northwest portion of the site and contains 8 parking stalls that contain porous pavers. Runoff from this basin will either enter the storm system via the porous pavers or be collected in a concrete pan and conveyed east into Basin 5. ' There is no offsite flow entering the site from the north, west or east. The flow from the west is intercepted by Riverside Avenue and the flow from the east (railroad) is captured ' in a swale in the railroad right of way. Runoff from the north is contained on that site and routed away from this site. Runoff from the site to the south flow in two directions. The west half of the site is captured in an existing curb and appears to pond on site. The ' east half of the site drains to the east and north. This flow will enter the Riverside Storage site in the grassed swale along the shared property line and will enter the detention pond. ' This runoff will not be detained but will flow over the spillway and enter the railroad right of way as it has historically done. The spillway was sized with a 0.25' flow depth but the spillway will be constructed 0.74' deep therefore sufficient overflow capacity is provided in the spillway. ' Drainage design for this site has been designed to convey on -site runoff to the proposed detention pond and incorporate the required water quality enhancement features. On -site runoff will be conveyed to the detention pond via surface flow in the drive aisles, in the ' LID swales and subsurface in the perforated pipes. The detention pond will release the detained runoff from the site at the existing (historic) 2-year runoff rate of 2 cfs. The ' developed 2-year runoff rate for this Site is 3.8 cfs and the developed 100-year runoff rate is 19.3 cfs. 5 I ' 4.3 Drainage Summary This site has been designed to meet or exceed the "City of Fort Collins Storm Drainage ' Design Criteria Manual" specifications with exceptions noted in Appendix E. The proposed drainage design for this site has been designed to convey on -site runoff to the ' detention pond while minimizing future maintenance. The site incorporates LID (Low Impact Development) treatment areas including an LID swale with underdrain along the north property line, and an LID swale without underdrain along the south property line and permeable interlocking pavers in the parking stalls and in the entry drive aisles. Refer to the end of Appendix D for a table indicating the size of the LID treatment area and the area of the site that drains to that LID treatment area. All drainage facilities proposed with this project, including the detention pond and outlet structure are private and will be owned and maintained by the property owner or Owner's Association. 6 I 5. STORMWATER MANAGEMENT CONTROLS 5.1 Written Analysis The soils on this site are classified by the USGS Soil Survey as Kim Loam with a small area of Santana Loam and are classified in the hydrologic group B. The soils are described as having a slow runoff rate and the hazard of water erosion is slight and the hazard of wind erosion is moderate. The site is surrounded by developed sites including streets and paved areas. The construction shall utilize silt fence around the perimeter to control sediment transport from rainfall and from wind. The silt fence that is located in the proposed pavement areas will be removed prior to placing new pavement. Rock socks will be utilized in the existing curb and the newly constructed swales to capture sediments that are not fully contained by the silt fence placement. The locations of the rock socks will be in the areas ' of concentrated flow such as in the existing curb, at the new swales and on the existing concrete sidewalks as needed. ' The site will also utilize a vehicle tracking control pad to minimize sediment from being tracked onto adjacent pavements. Sediment that is tracked will be removed and placed within the site or permanently disposed of offsite. A concrete washout will be used on site during the concrete placement. All hardened concrete will be disposed of offsite. These BMP's have not been located on the site map due to the fact that the site is very small and these BMP's will need to be placed by the contractor in locations that are most beneficial and will minimize disruption of adjacent traffic. tPermanent erosion control consists of covering the soils with a building, concrete walks, ' concrete drives and sod. No soil will be left exposed to erosion after the construction is complete. Refer to the landscape plan for areas of and instructions for placement of sod and soil amendments required prior to placement of sod. ' Refer to Appendix D for the timing of the construction phases and the sequential installation of all BMP phasing for this site. Refer to the Appendix D for the Erosion Control Surety calculations. 7 5.2 SWMP contact information Permit holder: Name: Address: Phone Number: Email Address: Appointed agent: Name: Address: Phone Number: Email Address: 1 1 1 1 1 1 8 I 5.3 Identification and location of all potential pollution sources Potential Pollutant Source Activity Potential Pollutant Generated Applicable to this project Disturbed Areas Sediment X Soil stockpiles Sediment X Travel to adjacent public streets Tracked sediment X Contaminated soils Sediment, chemicals Loading and unloading chemicals Chemicals Unloading of building materials Trash, debris X Outdoor storage of chemicals Chemicals On site equipment maintenance Oil, grease On site equipment fueling Diesel, gasoline X Dust generating activities Particulates, sediment X Use of fertilizer, pesticides, herbicides Fertilizer, pesticides Use of detergents, solvents, oils Detergents, solvents, oil X Waste dumpsters, waste piles Chemicals, trash, debris X Concrete washout Concrete, sediment, wash water X On site equipment washing Detergents, oil On site asphalt batch plant Asphaltic cement, sediment On site concrete batch plant Cement, sediment Portable toilets Domestic sewage X ' 5.4 Best Management Practices (BMP's) for Stormwater Pollution Prevention ' Structural Practices for Erosion and Sediment Control Structural practices for the site will consist mainly of silt fence and rock sock filters and are described in detail in the following paragraphs. These BMP's are expected to change as the construction progresses and it is the responsibility of the contractor to ensure appropriate BMP's are in place and/or removed at the appropriate time in the construction sequence. All temporary and permanent erosion and sediment control practices must be maintained and repaired as ' needed to assure continued performance of their intended function. Silt fence and rock sock filters shall be in place prior to commencement of construction activities. During clearing and grubbing necessary for silt fence installation, all cleared material shall be placed on the uphill side so that if erosion occurs from the cleared material, the sediment will be trapped and not transported downstream. Rock socks shall be implemented in the existing curb line as shown on the Drainage & Erosion Control Plan. 9 All BMP's shall be installed per the details shown on the construction plan set. Temporary & Permanent Structural BMP's: Structural BMP Approximate location on site Applicable to this Project. Silt Fence Site perimeter, refer to site map X Straw bale dams Rock Socks At existing sidewalk culverts, in existing gutters, refer to site map X Earthen diversion dams Vegetated swales Sediment trap/pond East boundary of site, in proposed det pond X Pipe slope drains Geogrid Inlet/outlet protection In the detention Pond X Culverts Riprap Erosion control mats Inlet protection Vehicle Tracking Control Pad At site entrance, refer to site map X Concrete Washout To be located by Contractor, near site entry X Non -Structural Practices for Erosion and Sediment Control: Soils exposed during the earthwork phase and landscape prep phase shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control is installed. No large amount of soils (in excess of 15 yards) will be allowed to be stock piled on site. Overburden from the utility pipe trenching will be piled adjacent to trenches upstream of sediment controls and will be replaced in the trenches within 72 hours. Excess excavated materials from the demolition and grading phases of the project that cannot be reused on site will be exported as it is excavated. This includes any asphalt pavement from the existing site that is to be removed. A vehicle tracking pad will be installed at a location most beneficial to the site construction as determined by the contractor. Vehicles will not be permitted in the excavated area if soil is muddy. Gravel sub base will be placed and compacted in the areas indicated for pavement following excavation. In the current pre construction state the site enables tracking of silt onto the adjacent streets during wet conditions. During construction activities the street will be monitored for foreign debris tracked out of the site and mechanical sweeping and clean up will be performed as needed. 10 No area shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed. Temporary & Permanent non-structural BMP's: Non -Structural BMP Approximate location on site Applicable to this Project Surface roughening Entire site X Soil stockpile height limit (less than 10') Perimeter vegetative buffer West and north boundaries of site X Minimization of site disturbance Mulch Seed & mulch stockpiles after 30 days Stockpile toe protection (silt fence, wattles or ditch) Preservation & protection of existing West and north boundaries of site X vegetation & trees Good site housekeeping (routine Entire Site X cleanup of trash & constr debris) Sweeping & scraping ofhardscape On and off site pavements X areas Heavy equip staged on site, properly maintained & inspected daily (no Staging area X onsite maintenance) I5.5 BMP Implementation ' 1) Phased BMP Implementation BMP's are expected to change as the construction progresses and it is the responsibility of the contractor to ensure appropriate BMP's are in place and/or removed at the appropriate time in the construction sequence. A construction sequence schedule has been included on the Drainage & Erosion Control Plan and included in the construction plans for this site. ' All BMP's shall be inspected and repaired or replaced as required to satisfy the conditions of the Stormwater Discharge Permit. All BMP's must be maintained and repaired as needed to assure continued performance of their intended function. Refer to Appendix D for the BMP schedule and estimated costs. 11 71 Materials Nnnrllino nnrl Cnill PrevPntinn- Materials Handling & Spill Approximate location on site Applicable to this Prevention BMP Project Portable toilets, anchored & Contractor to determine X located away from drainages Fuel storage located in bulk tanks with secondary containment & spill kit Mobile fueling performed at least 200 feet away from drainages & Contractor to determine X fully attended Fertilizers, form oil, solvents, cleaners, detergent stored in 55 gal Contractor to determine X or smaller containers, kept in storage units Dumpsters containing used chemicals containers & liquid Contractor to determine X wastes kept covered Equipment cleaning (on site) uses no detergents & flows to onsite retention basin In case of a release of fuel or other chemicals, absorbent booms or earthen berms will be immediately Location of spill X constructed to contain the spill & prevent runoff to adjacent surface waters MSDS sheets for onsite chemicals will be kept at the construction. Contractor to determine X trailer to facilitate spill response & cleanup ' 3) Dedicated Asphalt or Concrete Batch Plant: Not proposed with this development 4) Vehicle Tracking Pad: ' Vehicle tracking control pad shall be installed wherever construction vehicle access routes intersect paved public roads. Vehicle tracking control pads shall be installed to minimize the transport of sediment (mud) by runoff or vehicles tracking onto the paved surface. Any mud Itracked to public roads shall be removed on a daily basis and after any significant storm that causes sediment to be transported. It is unlawful to track sediment/mud onto public streets ' and may be enforced by the City of Fort Collins, by the State of Colorado or by the EPA. 12 5) Waste Management and Disposal: Portable toilets will be anchored & periodically maintained by waste management company. Dumpsters on site will be covered & periodically emptied by waste management company. Concrete waste will be allowed to harden and then will be removed from site. No washing activities will occur on site. Location of the concrete washout is shown on the site map. The washout will be sufficiently deep to accommodate all anticipated concrete truck wash water. Waste concrete will be allowed to harden and be removed from site periodically as the washout reaches 50% of its capacity. Truck wash water will not be allowed to reach the curb & gutter or any other water course. 6) Groundwater and Stormwater Dewatering: No groundwater was encountered during soils exploration therefore ground water is not anticipated to be an issue. If groundwater is encountered a groundwater discharge permit shall be obtained and a detailed report shall be completed describing the location and the route of where pumped groundwater will be conveyed and the measures taken to prevent the transport of any pollutants to downstream waters. 7) Inspection & Maintenance: It is required that routine site inspections are performed to effectively address maintenance and repair of Best Management Practices (BMP's). The site inspections are to be performed by the contractor or an inspector designated by the administrator at a minimum of once every fourteen (14) calendar days on active construction sites and after any significant storm event (an event causing runoff). As part of the site inspections the inspector is required to keep documentation of all inspections and BMP maintenance, including an updated Site Map indicating new BMP's or the removal of BMP's since the previous inspection. Any maintenance, repair, or necessary installation of BMP's that are noted during the inspection must be completed within seven (7) calendar days from the date of the inspection. 13 6. CONCLUSIONS 6.1 Compliance with Standards All computations that have been completed within this report are in compliance with the "City of Fort Collins Erosion Control Reference Manual for Construction Sites", the "City of Fort Collins Storm Drainage Design Criteria Manual", and the "Urban Storm Drainage Criteria Manual" except where variances are requested as noted in Appendix E of this report. 6.2 Drainage Concept The proposed drainage concepts presented in this report and on the construction plans adequately provide for the collection and conveyance of on -site runoff to the detention area. Conveyance elements exist to adequately convey detained runoff downstream. If, at the time of construction, groundwater is encountered, a Colorado Department of Health Construction Dewatering Permit would be required. 14 7. REFERENCES 1. Urban Drainage and Flood Control District, "Urban Storm Drainage Criteria Manual", 2001 Edition Volume 1 updated June 2001, January 2004 and April 2008; Volume 2 updated June 2001 and April 2008; and Volume 3 updated November and December 2010. 2. The Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual, adopted by the City Council of the City of Fort Collins, as referenced in Section 26-500 (c) of the Code of the City of Fort Collins. 3. ORDINANCE NO. 152, 2012 of the Council of the City of Fort Collins amending Chapter 26 of the Code of the City of Fort Collins and the Fort Collins Stormwater Criterial Manual to incorporate provisions implementing Low Impact Development (LID) Principles. 15 ' APPENDIX A ' VICINITY MAP A CACHE CA POUpRf NIX NATURE AREA BUR��HCTO N /V0'y RH A A 7F7C CATTAIL CHORUS NATURE AREA E. PIT IN ST J w > Uj 0 E PROSPECT RD V) > tY F- N EDORA PARK x J 0 E. gTUAR? Li 37 Of w m r-- (N SHEET 1 OF 1 DATE: 10/10/14 1640 RIVERSIDE DRIVE North Star SCALE: 1•=1000' (RIVERSIDE STORAGE) VICINITY MAP '�� design, inc. 700 Automation Drive, Unit Windsor, Colorado 80550 Phone: 970-686-6939 DESIGNED BY: PPK JOB NO.: 264-03 Fax: 970-686-1188 BDt19Y90[fi +Yi 6Lfi99830[6 :•Iwd Yea is a-o.6 a`hcx +o'd NVId 10 i11NOJ NOISOLI3 >? 3`Jtl NIV210 °` o Ym Re w•6�vo �OUI'ufvsapM.... Y�� ^x c3Ovaols 3aISH3AIHI IVId3H CIN003S NOISIAI ens o �01$ ytao�j1 -..'.fir` 31.Q i'�a/a :,,,a 3OISH3A18-103dSOad 3 • 4 bAe 5 a gi..n �Y [ s fifi £[ - ii5 •D 5=�,', 0! aYEa bo' £5�a :3. a6$ :�" = E E E E p E b vEfiaaD bi €a�f�• fi yY •5 fra.`'` rc mAb o DY S.ifie �55SaFiHEY:fi3g= ea£ Cal 5Y^E M- a`{a,- E. .�;` `=6 o•a �e ko'aM1 �gN eDiY a E' HIE•dliba b a fiBaY3 �a'a .yam a 5. - b Y a5E3%YY E3i _". 8 igy Y. ,•p 'ea?:..'F fi.:g xy`Ei";¢ D'i. `_• u eEW` �geOE]i �_ 1 f a ff4 Ea iD`v; fitic's3i: - fines 9L�F -YBY {M1 J 8 a :'S. e5'a'eE' Ee :`--gig. aa.!;I. i{- i "aiY a'fi% WNW Y ••i•a .a=- a%5 E, ° S ¢ 1sz, 3Y E,a5% fiE ¢3 SSoo es bo¢a 31 _�Ep o ,tl8ia S d d g :a YnY•j _ •fi =a!; •' • ffla 8 6.512s8 %¢._ `:4a %'fq a"='ep :E yfiadc' €e {' _ . 48aii E€ :s==¢ Did° as EeecY drib E•=a QL e'.5_ �asfi °W �5laz EE6? aye€ 6P.= ______________________ ` __ ______ _____ 5 __ _ __________ _ ______.u.______ ______ ___ ___________L __ e x 6g9t �D _ _ _ __�--- —_ ---------- @_________- _ , I nimmmmmn nmmmmnml ■Inn�nnnnn�� n��nnn�nn�nn �Inn�nn��n��n nnn�nnnnnn� oln�nn���nn�n nnn�nllnn�n��l olnmm�nmm oinmmmmn �n I� n �n� �n� n�� I1I imi �'I �� �I ���II�InIIn��Iln�l �1I I� Ind ��I I� umml Immn InI In� II I11 I� I1I p� In�l ommunmim ommmm�l um 0�1�bl11nnn1n111 IN ICI4In 111111111111 I- I I $Ge '1 ga- J i v' �L_' I- ' d- `III �I' nl I I a�� • —9_n I I -_ —I j sa II I •� =1i A` ' b^. a== 06 a I i I I ' II 1 1 e I ✓i.p I gege I p g� / � I � a ! � Q `rye--) ` � Gv ❑ � e" 0 • D �- �- �I ¢Ii4°i '!i\ @a,¢�8E ; y tl .eW ���lllsss��� ' 9 0 Q ' � •b yn tl� % e �- ¢Y ' bi i 5� V., is �!�" / � �p� I I vg'� a• �� � 6� Y; Ex9g �� E£°a° E� s I:e. r X I YpL9Ya •b%,� jig a tlaaiyy 5g D ibY.5 E ae -vE Y�6pt ;.6.:3 „d p _. I it ��i^ �i, :•, I / Y ®' � s"Y@ a Y a iY al ¢E�S p53 Y"�'S a$3. q= s Sa e Y €!a °-"_ v tl a E Y eyae 8; 9� i s� �i¢e i i 3i¢ 5 . "Y if ¢ Y Yv YESY Ysa� �c v a 31, ar e' a �e i' F:5' Ya 'ii¢ tltl 444p gEa r$ R s� yaExj 1Y: x*�"p g8aba ei it s d 4¢H IN Y ¢ ¢ Y wh Eadb?b .�y 5} a■ eC g$ SsB CP• 3YDYT a6¢ D " b Yi dbC Y_Ye¢YYY:Sa ^ E • Y -] y��_f I'm 3�ldlam-Y qx Y Ila p¢ E Ei D� d SDb.D tla• a C D� tl b5 C F`Y 83 Y� Y tl y¢q yd¢PP,¢ x49 ¢c� Fa 7e $R: ¢��'gg _ 3R-Eb !>:�3b;SS'�S MA y' Y Y y r H all E¢3�3 .,::.YBYY D _a IAPPENDIX B tHYDROLOGIC & HYDRAULIC COMPUTATIONS u 0 j{°\§))§ a{ K e= _ f 0U. ; 222&2:2;25 §§- e «(/\(//7/2 r{ ./ ! §!F § ` ---- z \0:� � k:# , �ff §�{ [ - -- 0w ° °((\°\°}°Oct Q uj !wr )//{[}§[§} )■# # #, a , §//;§)2/§] §$# ; z6 \\ x ; „ �,�<�o0 j ( e a)«\ a �\j\ \ §)G ) )%)) \ \\D { \§\) 1�f'.' 'g < Q7 \§ \� \ \ § Q W N r I a Z N 0 K F O �O O Z W U Z w 0 U = O LL 0 'v1 ,> CW C � N ce U L 6 0 F N C4: p o Q y O M ,- LL N 6 1� II U } m z o° O F F F Via=. o �aOU� cal Y K LU W K J LL „" O Z + N O C N lh fh N N (O Q Q m r r U v.— N O--- O N O O O N W 2 u U N Z O Q J F O+ J LL C r t0 N r O r fh fh m r J W _ O «O' r 10 tD 1p Q r Y] M W a0 N Z Z R O O O V Q _ O It 0 C L c O 0 0 0 0 0 0 0 0 0 0 m 0 (7 O o O hl — O N O O O J L F m J _= N II N QI Q W O 01 r ch 0. Q Q 0 m Z o N aD O O O O O O O O O O O � ul J H � Q F Z_ co o nl o In m U � Q N r w ;TIT m r r 0 0 0 0 0 0 m m c�ID v•-moNmolo Q Q N � z m J fn Q Hco NM Q u1 QD](_7F m [D W EnEn D w Z F 0 co Nt7 Q N QfDU� wa CV U O 3 LL C N O O � N LL'Z w O K F O LL 9 a Z G W Z V N Z O U LL O W � H w L yam. 6 O n O n C � L p In O M Ii. N 6 l� I U m z O Z O ¢ a O F U m !y ?, OJ�U� o c o`vmi aco om o m O n E V 0 N � O L Q y 0 O C Z O 5 Y C W LL' J Q C y m O O O N O O 0 0 Z Y E v N r m ui m vi vi vi vi u� lti LL O = 4 a m cm � mm�nN m a amrr U W IUD = U N « 2 ya0 0 o vo r m m 3 N U zz.z r 6 M 6 N of N w J LL J C r m N r O r m m m r W O^ r m Ip Ip v r N m m m m 2 2 Q U—y H m o � q m m m m m w > O V O rn c t o 0 0 0 0 o m m m m m LL � c�c m m 0 m mm 0 0 0 mm 0 0 0 0 0 0 0 F s o O O p O O O O Or C G G C 0 Ill G 0 O a m -0 �7 O O m O m m m J w 5 J _ � o m �nm0 mm rmm m m n^ O^ -� � m o 0 0 0 0 0 0 0 0 0 O m N � lV N T Z J L 0000 O mrO�m � � � m v m OW J J Q U m m N O m N O 0 m m F, Ili m o m m O n O m m Om U M O N A r N m arD Of n� 0 0 0 0 C G G G G 0 0 m m m C!Om Nmo m ` 1 N N O 7 0 N O N Q� N 00 O O O O O O N F � z a J a m m � � rn M 2 H � 2 W O N m p m Q m U m a o O U 0 LL LL 0 Z 7 Y Q W a � w 0 o N 2 � > N LU o J � Q N 0 F a Q U d N O G 0 n L p O O N1 n U m y z O � F N O F F Fu a U p F OcCOQ J a U m N N N � c N N N ca N 0 N > N > N > O N N N V a a a N _ Cd_ co co In a O O O ❑❑❑- N 0 0 0 C J J J .__ ❑ a a a W ul K Q F H F H F F F F F J ro FN U O O Nl lh N I* 7 N O C0 Q Q N O O O O O N O O O m F � N U OO } C of U E o m "o a ❑ N N Icl O O O O O N O O O M 3 L N N N N N N T N N N eD _ d O V V of eD N N O N C N fV N N N IV NNV fV N N N O_ N c0 N O O O V 0 0 0 N LL .0. E N r r N N E t0 to N N OI LL Q Z oclo�Co V N 1� m n 00 OO W Il r F U o 0 0 0 0 0 0 0 0 0 0 U w K U w m w`— Ol N N a0 ow Q N O O N O N c O F w F c ❑ a a 1 LL LL 0 2 ' 7 Y Q Way ' 0 W Q } O F- O W v � J J � Z 0 Y. v 6 O a` 0 ' n 4 = U O � o. ry c n II U } O � N ' p � o F O_ F :D 1 U 0 V OcCO¢ c J G U C d 5 > o C N � C ' m � O C m 0 O 0 fA j H = < v c o Sc_ Z n > 1 1 Y E E E m od E E E E E N h N T N N W m 3 m 3 m 3 0 > > > It N N # a d o 0 o v 0 o 0 0 0 0 0 n 7 7 i o a a a 0 0 0 0 0 0 0 0 0 r r r r r r r r r J Q Q O m OI th v o M Q r o K O p W � U o a } K 0 O th Q wmmmmmmmmm � U � V •- O O O N O O O C LL LL O Z O' U c0 N �O N N O> O O O> aD N M O O O O O O f7 rn c0 m U W K U Q m m M O O^ 7 A O O N N O N O N to N 0 0 0 0 0— C O O N 0 OI O C J Q 41 'w N lh O N Q m U Q .X O C W r o a Z U LL 0 E 0 N L y v C U L C U N n U E N `o _ N II 11 II aU_'¢ O_ O AREA INLET IN A TRAPEZOIDAL GRASS -LINED CHANNEL Riverside Storage Inlet 1 Ti, i Grass Type Unsling Mannin 's n _ A 0.06 e 0.04 a C 0.033 D 0.03 �. _.._._... .._....... .�/ t E 0.024 F(— B Analysis of Tra emidat Grass -Lined Channel U.mn SCS Method RCS Vegetal Relardance (A, B. C, D. or E) A. B. C, D or E - Manning's n (Leave cell D16 blank to manually ender an n value) n Channel Invent Slope So = 0.0270 Wit Bottom Width B= 1.W It Left Side Slope Z1 = 10.00 Wit Right Side Slope Z2= 500 6/ft Check one of the following wit types Sod�T ae'. Max. Velocity, W....1 Max F.W. No. IF,...1 Q senty Sandy 5.0 fps 0.50 ® Non -sandy Nan 7.0 0.80 Minor sbm Major Stone Max. AAmvebb Top KrHN at Charnel for Mron 8 Major Storm Teu = 10.00 10.00 feet Max. ADowable Water Depth in Chwrel for Miry 6 Major Stem dear = 6.00 6.00 feet towable ChannelCapacity Based On Channel Geometry Minor Storm Major Storm MINOR STORM Allowable Capacity is bawd on Top Width Criterion O, = 1.26 1.28 Ns MAJOR STORM Allowable Capacity is based on Top Width Criterion d. = 0.60 0.68 ft Baastl On Deai nPaak Flow O,= 0.10 0.30 c7s rW�n.nnell it 0.20 O.Sf fast llowable capacity GOOD - greater than flow given on sheet'O-Peak' Maiorstormma,. allowable aaoacftv GOOD- greater than flow given on sheet'O-Peak' Hat 1.1dsm, Area Inlet 7/3012015, 3:39 PM AREA INLET IN A TRAPEZOIDAL GRASS -LINED CHANNEL Riverside Storage Inlet t Dasian hdormztlon flop A , Of Inlet Inlet Type = CDOTTWeC P of lndined Grow (in" be <= 30 degrees) 0= ow degrees i or Grate W= 3.00 feet '.h of Grate _ .�"� ���- L= 3.00 feel Area Ratio „.^ ".` •.._ Awro= 0.70 a of Inclined Grate W,r' He= 0.00 feel limit Factor „✓ ,..':—( -•,•.. C,= 0.50 Oisrliarge coefficient l`-( 'f-•w .•` - �° Cu= 0.90 e coaffidera a ,,.. G-_t C. Dee MINOR MAJOR r Depth at Inlet (for depressed Wells. t foot is added for depression) it = II Inlet Interception Capacity (assumes clogged condition) o, = cfs Capacity IS GOOD for Minor and Major Stones(>O PEAK) Bypassed Flow, O.= cfs Capture Percentage= OJO, = C % 0.20 0.33 1.W l.d] 0.00 O.Oe 100 100 Warning 02: Depth (d) exceeds USDCM Volume I recommendation. INlel 1.xism, Area Intel 7/30/2015, 3:39 PM AREA INLET IN A TRAPEZOIDAL GRASS -LINED CHANNEL Riverside Storage Inlet 2 T1_ Grass Type Limitln Mannin 's n `( A 0.06 �.... i T o �.✓_�_,--. B 0.04 / C 0.033 `�� O f/fr drnnx D 0.03 � .... ... - _C t E 0.024 F--(— B nor sis of Trapezoidal Grwxs lnal Channel Using SCS Method NRCS Vagetal Reterdaree (A, B. C. D, or E) A. B. C, D or E Manrdng's n (Leave call Of 6 blank to manually enter an n value) n = 0.300 Charmel Invent Slope So = 0.0350 ft/ft Bodom WloN B= - 1.W 0 Left Side Slope zl = 4 00 ft/ft Right Side Slope Z2= 1 .W ft/ft Check one of the followi spilt Soil Max. Velocity (V....1 Max FroW a No, (F.-, a S-rdy Sandy &0 fps 0,50 ® Nnn Sxidy Nor-Serxt 7.0f s 0,80 Mirror Storm Ma'or Slonn Movable Top WMN of Channel(or Miror 8 Major Storm Taex = 10.00 10.00 test Max. AAowable Water Depth in Channel for Minx 6 Major Storm da,u = 6.00 6.00 Ifeet STORM Movable Capacity Is based on Top Wldm Criterion STORM Moveable Capacity Is based on Top Width Criterion peak Flow storm max. allowable capacity GOOD - greater than flow given on shoet'O-Peak' storm max. allowable capacity GOOD - greater than flow given on shoot'O-Peak' 1.63 C, -1 0.20 1 1.00 oh dzl 0.26 1 0.52 1heet Inlet 2.xlsm, Area Inlet 7130/2015, 3:39 PM AREA INLET IN A TRAPEZOIDAL GRASS -LINED CHANNEL Riverside Storage Inlet 2 rlet Design Infonnrtion INputl ype of Inlet Inlet TypeCDOTTypeC Asia of Indirwd Grace(must De<=30 degrees) 0= am degrees YMthgf Grde W= 3,00 feet mglhof Gme "I , _ L= 3.00 feet Ipen Area Ratio Aexrp = 0.70 Ieight of lridirietl Grate logging Faoor ,,-<.__,. —... ....�_�"'.•�_ Ne= „.---- "_' /� G= 0.00 050 feel {rele D'adwge Coefficient-, ^..�"" �-' _.•../~ NA Ca 0.00 Idfce Coelfidenl ""� .._ -__'^. "Y" n ._d Ce O13s ye'v Coefficient ""t-.._ "'-,--�. 1'" C. 2.05 �^_' MINOR MAJOR View Depth rt Inlet (for depressed inlets, 1 foot is added for depression) d = 0.28 0.52 'Dial Inlet Interception Capacity (assumes clogged condition) �. = zs7 aoz cis filet Capacity IS GOOD for Minor and Major Storms(>O PEAK) Bypassed Flow, De= 0.00 0.00 ofe Capture Percentage = QIO. = C%1 100 100 % Warning 02: Depth (d) exceeds USDCM Volume I recommendation. Inlet 2.KISm, Area Inlet 7/30/2015, 3:39 PM LL tJ3 jUI tW°Ott O 16 Irl %O N Oi aD N Ill Ill y v � i 00 V . Ill .� . Ill . . Ol Ol n S c3v � o Ol O N O Ol N O O O t0 �O N E N J Go O m I'1 I+OI M m m M M M m M M ' n3 � o ool�ll�rnMLqcnvommlrr! a E y v? M m M M m M R M m M C7 n3v ' 7 O co of of cd of co of z of w w w M M M M M M M M M M M W dul�Ci *n 3 7 QO 0 j 03 E�tYrA U U Q zn3 oat.o oo o'o a w w o O 0 LL nCr �-Ci d J d d J O -E m Il) IO IO O] 0 O O O O O O In'v O O O O O O N (V OJ Ill N N �v 0-. a N N G G 4 N n n n n n n 'a a 'a a 'a 'a mo > a o o o Urn E m m `ooa rn T m C m m (q)uoga ala f M� wC N W ww�, W N LL E O¢�> � U a- O O O O O l() a in (4) u01lene13 En dN m C 0 m O U � oU ' 3 in o m m 0 v o LA MO N ziN m 0 O = J N C > + m E >� m M `N m T n N Q yU @o m E m y 05 N APPENDIX C DETENTION POND SIZING CALCULATIONS C MINIMUM DETENTION VOLUME REQUIRED FAA METHOD (100-YEAR) LOCATION: First Replat of Prospect Riverside Subdivision PROJECT NO: 264-10 COMPUTATIONS BY: PPK SUBMITTED BY: North Star Design, Inc. DATE: 7/30/2015 Equations: A trib. To pond = 2.16 QD = CiA C100 = 0.98 V; = T*CiA = T*QD Developed C*A = 2.1 V. =K*QPo*T QPo = 2.0 S=V; -Vo K= 1 Rainfall intensity from City of Fort Collins IDF Curve acre acre cfs (from fig 2.1) Storm Duration, T (min) Rainfall Intensity, i (in/hr) QD (cfs) Vol. In V; W) Vol. Out Vo (ft) Storage S (ft) Storage S (ac-ft) 5 9.95 21.1 6319 600 5719 0.131 10 7.72 16.3 9805 1200 8605 0.198 20 5.60 11.9 14225 2400 11825 0.271 30 4.52 9.6 17222 3600 13622 0.313 40 3.74 7.9 19000 4800 14200 0.326 50 3.23 6.8 20512 6000 14512 0.333 60 2.86 6.1 21795 7200 14595 0.335 70 2.62 5.5 23293 8400 14893 0.342 80 2.38 5.0 1 24t82 9600 14582 1 0.335 90 2.22 4.7 25376 10800 14576 0.335 100 2.05 4.3 26037 12000 14037 0.322 110 1.93 4.1 26964 13200 13764 0.316 120 1.80 3.8 27434 14400 13034 0.299 130 1.60 3.4 26418 15600 10818 0.248 140 1.40 3.0 24894 16800 8094 0.186 150 1.20 2.5 22861 18000 4861 0.112 160 1.15 2.4 23369 19200 4169 0.096 170 1.10 2.3 23750 20400 3350 0.077 180 1.05 2.2 24005 21600 2405 0.055 Required Storage Volume: 14893 It 0.342 acre-ft �0000 ooao° a000 oaoa I LOCATION: PROJECT NO: COMPUTATIONS BY: SUBMITTED BY: DATE: WQCY 100 WSEL STAGE - STORAGE TABLE (100-YEAR) First Replat of Prospect Riverside Subdivision 264-10 PPK North Star Design, Inc. 7/8/2015 100 yr Detention Volume Required = 0.342 Water Quality Volume Required= 0.076 Total Volume Required= 0.418 Stage (ft) Surface Area (ft) Incremental Storage (ac-ft) Total Storage (ac-ft) 4934.30 0 4935.0 7,850 0.042 0.04 4935.30 9,528 0.060 0.102 4936.0 1 13,442 0.242 0.284 4936.36 19,395 0.134 0.418 4937.0 30,070 0.487 0.770 Detention Pond Outlet Sizing (100 yr event) LOCATION: First Replat of Prospect Riverside Subdivision PROJECT NO: 264-10 COMPUTATIONS BY: PPK SUBMITTED BY: North Star Design, Inc. DATE: 7/30/2015 Submerged Orifice Outlet: release rate is described by the orifice equation, Qo = Copt sqrt( 2g(h-E.)) where Qo = orifice outflow (cfs) Co = orifice discharge coefficient g = gravitational acceleration = 32.2 ft/s k = effective area of the orifice (ft) Eo = greater of geometric center elevation of the orifice or d/s HGL (ft) h = water surface elevation (ft) Qo = 2.0 cfs outlet pipe dia = D = 12.0 in Invert elev. = 4934.30 It Eo = 4934.61 ft h = 4936.36 ft - 100 yr WSEL Co = 0.62 solve for effective area of orifice using the orifice equation Ao = 0.304 ftz = 43.8 in orifice dia. = d = 7.47 in Check orifice discharge coefficient using Figure 5-21 (Hydraulic Engineering) d/D= 0.62 kinematic viscosity, u = 1.22E-05 ftz/s Reynolds no. = Red = 4Q/(pdu) = 3.35E+05 Co = (K in figure) = 0.62 check Use d = 7.50 in A0 = 0.307 .it? = 44.18 in /�z Emergency Overflow Spillway Sizing LOCATION: First Replat of Prospect Riverside Subdivision PROJECT NO: 264-10 COMPUTATIONS BY: PPK SUBMITTED BY: North Star Design, Inc. DATE: 5/24/2005 Equation for flow over a broad crested weir Adbffm Q = CLH" � spill �IsdN�4i®n where C = weir coefficient = 2.8 L H = overflow height L = length of the weir 900 yr WSEL The pond has a spill elevation 0 ft above the maximum water surface elevation in the pond Spillways will be designed with 0.25 ft flow depth, thus H = 0.25 It Size the spillway assuming that the pond outlet is completely clogged. Q (100) = 19.0 cfs Spill elev = 4936.36 It 100 yr WSEL = 4936.36 ft Top of berm elev.= 4937.10 Weir length required: L = 54 ft Use L = 55 ft v = 1.21 f /S l Stormwater Detention and Infiltration Design Data Sheet Workbook Protected Worksheet Protected stormwater Facility Name: Riverside Storage Facility Location &Jurisdiction: Riverside Avenue, Fort Collins User (Input) Watershed Characteristics Watershed Slope= 0.007 ft/ft Watershed Length -to -Width Ratio= 1.68 L:W Watershed Area = 2.16 acres Watershed Imperviousness= 74.0% percent Percentage Hydrologic Soil Group A = 0.0% percent Percentage Hydrologic Soil Group B = 0.0% percent Percentage Hydrologic Soil Groups C/D = 100.0% percent Location for 1-hr Rainfall Depths (use dropdown): Use, Input User Input: Detention Basin Characteristics WQCV Design Drain Time= 40.00 hours After completing and printing this worksheet to a pdf, go to: httas://manerture.digitaidatasemices.com/evh/?viewer--awdif create a new stormwater facility, and attach the pdf of this worksheet to that record. Routed Hydrograph Results Design Storm Return Period = One -Hour Rainfall Depth = Calculated Runoff Volume = OPTIONAL Override Runoff Volume = Inflow Hydrograph Volume = Time to Drain 97% of Inflow Volume = Time to Drain 99%of Inflow Volume = Maximum Ponding Depth = Maximum Ponded Area = Maximum Volume Stored = User Defined Stage [ftl User Defined Area [ft-2] User Defined Stage [ft] User Defined Discharge [cfs] 0.00 0 0.00 0.00 0.70 7,850 0.70 0.03 1.00 9,528 1.00 0.03 1.70 13,442 1.20 1.44. 2.06 19,395 1.70 1.80 2.70 30,070 2.06 2.02 2.10 38.96 2.30 71.57 2.50 110.19 2.70 154.00 FEE] WQCV 2Year 5Year 10 Year 25 Year 50 Year 100 Year 0.53 0.98 1.36 1.71 2.31 2.91 3.67 0.052 0.128 0.193 0.255 0.367 0.475 0.619 0.051 0.128 0.193 0.255 0.366 0.474 0.619 37 63 61 59 56 54 51 41 68 68 66 65 64 63 0.61 1.00 1.11 1.22 1.49 1.76 2.05 0.156 0.218 0.233 1 0.246 0.281 0.329 0.440 0.047 0.122 0.148 1 0.173 0.244 0.325 0.438 n cre-ft cre-ft cre-ft lours lours t cres cre-ft SDI_Design_Data_FC_Rainfall.xlsm, Design Data 8/21/2015, 4:53 PM Stormwater Detention and Infiltration Design Data Sheet 14 1 1 1 —100YR IN I 1 I I I — — 100YR OUT 1 12 —50YR IN I I I I I — — 50YR OUT i I —25YR IN I I I ! I I I 10 --- 25YR OUT I I R —10YR IN --- 10YR OUT I _ I I I �SYR IN 0 •••••• SYR OUT 1 LL 6 -2YR IN I _ I — I .! I I --- 2YR OUT I 4 —WQCV IN ! ! ...... WQCV OUT 2 _ 04' .�' — _ . - � • I I ' I ` o -- — 0.1 1 10 TIME [hr] 2.5 —100YR —50YR 2 —25YR I —10YR 1.5 —2YR z —WQCV O I I I I 0-5 I 0 0.1 1 10 100 DRAIN TIME [hr] SDI_Design_Data_FC_Rainfall.xlsm, Design Data 8/21/2015, 4:53 PM ' APPENDIX D BMP SCHEDULE & COST ESTIMATE Erosion and Sediment Control Escrow/Security Calculation ' for The City of Fort Collins ' Project: Riverside Storage Disturbed Acres: 2.18 l3MP Amount Estimated Unit Total ' EROSION CONTROL BMPs Units Quantity Price Price Silt Fence L.F. 1300 $3.00 $3,900.00 Rock Sock each 15 $85.00 $1,275.00 ' Vehicle Tracking Control Pad each 1 $1,500.00 $1,500.00 Concrete Washout each 1 $1,200.00 $1,200.00 Rock Berm each 1 $65.00 $65.00 (add all other BMPs for the site in this list) Sub -Total: $7,940.00 1.5 x Sub -Total: $11,910.00 ' Amount of security: $11,910.00 Reseeding Amount ' Total Acres x Price/acre: $2,616.00 Unit Price of Seeding per acre: $1,200.00 Sub -Total: $2,616.00 1.5 x Sub -Total: $3,924.00 ' Amount to Re -seed: $3,924.00 Minium_um_ Escrow Amount Minimum escrow amount: $3,000.00 Erosion Control Escrow: $11,910.00 ' "The amount of the security must be based on one and acre -half times the estivate of the cost to install the approved measures, or one and one-ha/jtimes Use cost to re -vegetate the disturbed land to dry land grasses based upon unit cost determined by the City's Annual Revegetation and Stabilization Bid, whichever is greater. /n no instance, will the amount ofrecurity be less than one thousand five hundred dollars (51,500) jor residential development or three thousand dollars (53,000) jor commercial development" 1 7/30/2015 2:33 PM N:Q2 10 RwmWe SWmgeWmmge%E mple Ewc ,xk CONSTRUCTION SEQUENCE PROJECT: RIVERSIDE STORAGE DATE: 7/30/15 CONSTRUCTION PHASE eeeeeeeeee®® GRADING (INCLUDES OVERLOT) mmmmmmmmmmm DETENTION / WO PONDS PIPELINE INSTALLATION (INCLUDES OFFSITE) SAINITARY SEWER STORM SEWER -r-INCRETE INSTALLA-MON (INCLUDES OFFSITE) CURB AND CUTTER PAVEMENT INSTALLTA-ILON BESTMANAGEMENT PRACTICES STRUCTURAL SILT FENCE IARRiEiRS CONTOUR FURROWS (RIPPING/DISKING) SEDIMENT TRAP / FILTER VEHICLE TRACKING PADS FL#W 8ARRIERS (WATTLES, ETC) CONCRETE WASHOUT TEMPORARY SEED PLANTING MULCHING / SEALANT PERMANENT SEE# PLANTING S#Il INSTALLATION Riverside Storage LID Table New Impervious Area 72757 sq. ft. Required Minimum Impervious Area to be Treated (50%) 36379 sq. ft. Impervious Area Treated by LID Treatment Method #1 (LID swale with underdrain) 4850 sq. ft. Impervious Area Treated by LID Treatment Method #2 (LID swale without underdrain) 4800 sq. ft. Impervious Area Treated by LID Treatment Method #3 (LID swale without underdrain) 3373 sq. ft. Impervious Area Treated by Porous Pavement 17430 sq. ft. Total Impervious Area Treated 30453 sq. ft. New Pavement Area 38365 sq. ft. Required Minimum Area of Porous Pavement (25%) 9591 sq. ft. Area of Paver Section A 918 sq. ft. Run-on area for Paver Section A 108 sq. ft. Area of Paver Section B 1460 sq. ft. Run-on area for Paver Section B 6303 sq. ft. Area of Paver Section C 4644 sq. ft. Run-on area for Paver Section C 3997 sq. ft. Total Porous Pavement Area 7022 sq. ft. APPENDIX E VARIANCE REQUEST L, E ' Stormwater Alternative ComplianceNariance Application ' City of Fort Collins Water Utilities Engineering Engineer/OwnerSection A: Engineer Name North Star Design Inc. Phone 970-686-6939 ' Street Address 700 Automation, Unit I City. Windsor State CO Zip 80550 Owner Name Corey Seitz Phone 970-567-7549 Street Address 1019 Club View Road ' City Fort Collins State CO Zip 80524 ' Project Name Riverside Storage Project/Application Number from Development Review (i.e. FDP123456) ' Legal description and/or address of property Prospect -Riverside Subdivision Second Replat Description of Project Storage units and office uses ' Existing Use (check one): Cj residential C non-residential 0 mixed -use (E) vacant ground Proposed Use (check one): 0 residential Q non-residential 0 mixed -use C) other If non-residential or mixed use, describe in detail Storage units and office uses. Section C: Alternative ComplianceNariance Information State the requirement from which alternative compliance/variance is sought. (Please include applicable Drainage Criteria Manual volume, chapter and section.) What hardship prevents this site from meeting the requirement? See attached sheet Attach separate sheet if necessary What alternative is proposed for the site? See attached sheet Attach separate sheet if necessary ' Modifications of Criteria Three modifications to Criteria are being requested for this project. They are 1) A reduction in the freeboard for the detention pond, 2) A reduction in the required interlocking permeable pavers on site and 3) an alternative compliance for the LID requirement. ' The reduction in freeboard is being requested from the 1' requirement to 0.54'. The spillway is set at elevation 36.36 and the lowest building floor elevation adjacent to the ' pond is set at elevation 36.9. The buildings are used ONLY for storage purposes and the, reduction in the freeboard will not pose any risk to public health or safety. ' The reduction in the required interlocking permeable pavers is being requested from the 25% (9590 'so of the new pavement on site to 18.3% (7022 so. Originally it was intended ' to place the permeable pavers in the eastern portion of the site but due to slope constraints, this did not allow for the inclusion of a perforated underdrain which is desired. Therefore, the permeable pavers were moved to the west portion of the site into the areas that allow ' for the inclusion of an underdrain. The permeable paver area has been maximized but is still under the 25% requirement therefore a variance is being requested. ' The current requirement for LID (low impact development) is that 50% of the site imperviousness must drain through a filtering device (36,380 sf on this site). Currently, ' 13,023 sf drain to an LID swale and 17,430 sf drain to permeable pavers totaling 30,453 sf 01.8% of the site imperviousness). Other options to reach the required 50% have been considering including a bioretention area in the west portion of the site but this would be redundant to the LID swale that is proposed. The remaining option is to place an LID swale in the bottom of the detention pond but, because the elevations do not allow for inclusion of an underdrain, this is not a desirable option. page 2 The owner agrees to comply with the provisions of the zoning ordinance, building code and all other applicable sections of the City Code; Land Use Code, City Plan and all other laws and ordinances ' ....--.-.-----.-affecting_the-construction-and-occupancy-of-the-proposed-building-that-are-not-directly-approved-by-- this variance. The owner understands that if this variance is approved, the structure and its occupants maybe more susceptible to flood or runoff damage as well as other adverse drainage issues. 1640 erside, LLC Corey Seitz, Manager 9/8/2015 ' Signature of owner: Date: ' The engineer hereby certifies that the above information, along with the reference plans and project descriptions is correct. �1 i , / ' Signature of engi , /29/15/ g/tS PE STAMP Date complete application submitted: Q 8/ /s -------- - ----- ----- _. __...-.._...._....._......:... Date of approval/denial: 4 �O//S Variance: _.._......._............._...._......--_ Staff justification/notes/conditions: approved enied e n e Twt G e(ii r u[[ -�-t! Gh n, I vGs t' a fW / A a / G /�� 7 i I o �. ro • Approved by: Entered in Utility.File Database❑no. S APPENDIX F FIGURES AND TABLES F I (11) Section 4.0 is amended to read as follows: 4.0 Intensity -Duration -Frequency Curves for Rational Method: The one -hour rainfall Intensity -Duration -Frequency tables for use the Rational Method of runoff analysis are provided in Table RA-7 and in Table RA-8. Table RA-7 -- City of Fort Collins Rainfall Intensity -Duration -Frequency Table for Use with the Rational Method (5 minutes to 30 minutes) Duration (min) 5 2-Year Intensity (in/hr) 2.85 10-Year Intensity (in/hr) 4.87 100-Year Intensity (in/hr). 9.95 6 2.67 4.56 9.31 7 2.52 4.31 8.8 8 2.4 4.1 8.38 9 2.3 3.93 8.03 10 2.21 3.78 7.72 11 2.13 3.63 7.42 12 2.05 3.5 7.16 13 1.98 3.39 6.92 14 1_92 3.29 6.71 15 1.87 3.19 6.52 16 1.81 3.08 6.3 17 1.75 2.99 6.1 18 1.7 2.9 5.92 19 1.65 2.82 5.75 20 1.61 2.74 5.6 21 1.56 2.67 5.46 22 1.53 2.61 5.32 23 1.49 2.55 5.2 24 1.46 2.49 5.09 25 1.43 2.44 4.98 26 1.4 2.39 4.87 27 1.37 2.34 4.78 28 1.34 2.29 4.69 29 1.32 2.25 4.6 30 1.3 2.21 4.52 33 Table RA-8 -- City of Fort Collins Rainfall Intensity -Duration -Frequency Table for Use with the Rational Method (31 minutes to 60 minutes) Duration (min) 31 2-Year Intensity (in/hr) 1.27 10-Year Intensity (in/hr) 2.16 100-Year Intensity (in/hr) 4.42 32 1.24 2.12 4.33 33 1.22 2.08 4.24 34 1.19 2.04 4.16 35 1.17 2.0 4.08 36 1_15 1.96 4.01 37 1.16 1.93 3.93 38 1.11 1.89 3.87 39 1.09 1.86 3.8 40 1.07 1.83 3.74 41 1.05 1.8 3.68 42 1.04 1.77 3.62 43 1.02 1.74 3.56 44 1.01 1.72 3.51 45 0.99 1.69 3.46 46 0.98 1.67 3.41 47 0.96 1.64 3.36 48 0.95 1.62 3.31 49 0.94 1.6 3.27 50 0.92 1.58 3.23 51 0.91 1.56 3.18 52 0.9 1.54 3.14 53 0.89 1.52 3.1 54 0.88 1.5 3.07 55 0.87 1.48 3.03 56 0.86 1.47 2.99 57 0.85 1.45 2.96 58 0.84 1.43 2.92 59 0.83 1.42 2.89 60 1 0.82 1.4 2.86 34 I 1 1 1 1 10.00 9.00 6.00 t 7.00 N 0 L )_ 6.00 F_ H 5.00 2 W z 4.00 J J Q z 3.00 9 RAINFALL INTENSITY -DURATION -FREQUENCY CURVE 2.00 1.00 0.00 0.00 10.00 20.00 30.00 40.00 50.00 STORM DURATION (minutes) - 2-Year Storrs - - - 10-Year Storm -100-Year Storm Figure RA-16 City of Fort Collins Rainfall Intensity -Duration -Frequency Curves (13) Section 5.0 is deleted in its entirety. (14) Section 6.0 is deleted in its entirety. (15) Section 7.0 is deleted in its entirety. (16) Section 7.1 is deleted in its entirety. (17) Section 7.2 is deleted in its entirety. (18) Section 7.3 is deleted in its entirety., (19) Section 8.0 is deleted in its entirety. (20) Table RA-1 is deleted in its entirety. 36 60.00 I Table RO-10 Rational Method Minor Storm Runoff Coefficients for Zoning Classifications Description of Area or Zoning Coefficient R-F 0.3 U-E 0.3 L-M-In 0.55 R-L, N-C-L 0.6 M-M-N, N-C-M 0.65 N-C-13 0.7 Business: C-C-N, C-C-R, C-N, N-C, C-S 0.95 R-D-R, C-C, C-L 0.95 D, C 0.95 H-C 0.95 C-S 0.95 Industrial: E 0.85 1 0.95 Undeveloped: R-C, T 0.2 P-0-1- 0.25 For guidance regarding zoning districts and classifications of such districts please refer to Article Four of the City Land Use Code, as amended, 40 Table RO-11 Rational Method Runoff Coefficients for Composite Analysis Character of Surface Runoff Coefficient Streets, Parking Lots, Drives: Asphalt 0.95 Concrete 0.95 Gravel 0.5 Roofs 0.95 Recycled Asphalt 0.8 Lawns, Sandy Soil: Flat <2% 0.1 Average 2 to 7% 0.15 Steep >7% 0.2 Lawns, Heavy Soil: Flat <2% 0.2 Average 2 to 7% 0.25 Steep >7% 0.35 (4) A new Section 2.9 is added, to read as follows: 2.9 Composite Runoff Coefficient Drainage sub -basins are frequently composed of land that has multiple surfaces or zoning. classifications. In such cases a composite runoff coefficient must be calculated for any given drainage sub -basin. The composite runoff coefficient is obtained using the following formula: E(Ci *A,) C = ;=1 A (RO-8) Where: C = Composite Runoff Coefficient C; = Runoff Coefficient for Specific Area (A) A; = Area of Surface with Runoff Coefficient of C;, acres or feet n = Number of different surfaces to be considered A,= Total Area over which C is applicable, acres or feet (5) Anew Section 2.10 is added, to read as follows: 41 2.10 Runoff Coefficient Adjustment for Infrequent Storms - The runoff coefficients provided in tables RO-10 and RO-1 1 are appropriate for use with the 2-year storm event. For storms with higher intensities, an adjustment of the runoff coefficient is required due to the lessening amount of infiltration, depression retention, evapo-transpiration and other losses that have a proportionally smaller effect on storm runoff. This adjustment is applied to the composite runoff coefficient. Table RO-12 Rational Method Runoff Coefficients for Composite Analysis Storm Return Period Frequency Factor ears Cr 2 to 10 1.00 I l to 25 1.10 26 to 50 1.20 51 to 100 1.25 Note: The product of C times Cf cannot exceed the value of 1, in the cases where it does a value of 1 must be used (6) Section 3.1 is deleted in its entirety. (7) Section 3.2 is deleted in its entirety. (8) Section 3.3 is deleted in its entirety. (9) A new Section 4.3 is added, to read as follows: 4.3 Computer Modeling Practices (a) For circumstances requiring computer modeling, the design storm hydrographs must be determined using the Stormwater Management Model (SWMM). Basin and conveyance element parameters must be computed based on the physical characteristics of the site. (b) Refer to the SWMM Users' Manual for appropriate modeling methodology, practices and development. The Users' Manual can be found on the Environmental Protection Agency (EPA) website (http://www.epa.gov/ednnnnrl/models/swmm/index.htm). (c) It is the responsibility of the design engineer to verify that all of the models used in the design meet all current City criteria and regulations. ' 4.3.1 Surface Storage, Resistance Factors, and Infiltration Table RO-13 provides values for surface storage for pervious and impervious surfaces and the infiltration rates to be used with SWMM. Table RO-13 also lists the appropriate ' infiltration decay rate, zero detention depth and resistance .factors, or Manning's "n" values, for pervious and impervious surfaces to be used for SWMM modeling in the city of Fort Collins. 42