Loading...
HomeMy WebLinkAboutDrainage Reports - 09/02/20151 North Star design 700 Automation Drive, Unit I Windsor, CO 80550 Phone: 970-6866939 Fax:970-686-1188 July 23, 2015 Dan Mogen City of Fort Collins Stormwater 700 Wood Street Fort Collins, Colorado 50521 Re: Buckingham Street Design Dear Dan: City of Fort Collins Approv d Plans Approved by Date; 9 2oy This letter is accompanying the design plans for Buckingham Street from I" Street to 3rd Street. The original design plans for this section of Buckingham Street that were submitted (but not approved) with the New Belgium Brewery Canning Hall indicated that the detention for this portion of Buckingham would be provided at the southwest comer of the intersection of Buckingham and 1" Street. This detention required a complex storm piping design and rerouting of site runoff which was determined to be undesirable and not cost effective: With this redesign, the proposal is to route runoff from the north half of this portion of Buckingham to the existing New Belgium Brewery detention pond on the north side of Buckingham. All of the street area east of approximate centerline station 6+75 will flow to the east and into an existing: low area. No detention or water .quality extended detention will be provided for this runoff. In the future (approximately 3-5 years), a distribution plant will be proposed and, at that time, Buckingham will be widen from 3rd Street to Lemay. At that time, detention and water quality extended detention will be provided for the north half of Buckingham -Street from station 6+75 to Lemay Avenue. Calculations from the "NEW BELGIUM BREWERY, FOURTH FILING PACKAGING HALL & BUCKINGHAM STREET IMPROVEMENTS" by North Star Design, Inc dated June 2006 are included in this letter' update. These calculations show that the existing pond was originally designed to accommodate the runoff from the north half of Buckingham Street from Station 1+97 to Station 6+75. With additional improvements to the New Belgium Brewery site, the detention pond calculations will be updated to show,the impact of increasing the pond release rate from 1.15 cfs (current release rate) to 6.5 cfs (release rate accommodated in the new First Street storm system). I appreciate your time and consideration in reviewing the submittal. Please call if you have any questions or need additional information for this submittal of the project. Patricia Kroetch, P.E. z , \ r0 /) E G] C) \\ \u �\ / � 2! \\ \} \ $ \ - £ L) 7E _ L) \ .kE yk(\/ (§)u (( )2U0 )) § § § \ � § a2 r;^r f LL 0 ; §)` ,: LUw 2 ]$# ; § ! uj0: k�� (- I= ° §« e )<£ y# 2 �W� , )�■ :g § 2g �! U) 7 k o { )) }\/0 § \kE sfL)< < /< \L � k \ \ Y 2 Q w J Z« E� vim 0 IL "' Z � o c_m Q Ypp � Ev NOf �O o N v 2 W it Z it 0 N m 0 � J LL W = O O N Z E v N m Z v Q_ U 0 « w FC L m m m D O (' W O 0.0. O W N _ _ 00 0 0 J CO o0 0 w L F c'z!n my n � J m "' E v Cl lV fV W O O O O Q V V V Z Q J ;W ��v� O NN N O J F U 00 0 Z U em 00 � 0 N Q O G C H Z p z 55 Q Q �= C m mIF-:.W: N I J E II U U O s LL 3 C } O Z O F Z W U Z O U LL O W F- N F J Z Y N ¢C ~ G W F O J Z .• E � ui vi �o � o UJ WIU U � J ~m RCN Nm uNi F I + U � N W O J J W C O o N n z E z U 0 > It w W m FC L m m m � C C a (J @ O O O O W p o m v v v JNam-`-' co 0 aw C F m� � J m C O O < W O e O N O N O N 0 co v Z J s Lu 0 > N fN`1 N J J Z 0 0 0 W N U N m mN P i0 h ¢ �° 00. 0 F z o z q N m U m6 c 5 ¢ m mm m D w m N z F m m q 2z << U) Uo W a- 3 w O E n O U O x 0 4 K O O Z O `F z z w Zz O -u LL O W J Y K O a W O G' J a« C p O O o Z E v YI N N Z O a O C M N 01 O Y m m E c r = W U UN -- uQJ .+ m F - J LL W z �O E ov ri uN M z a x U O C L m m m W (� m o i d d d w $e ee Q 00 d = QW a f' CC1� m e m m J E `O w oa � o0 N V 0 V O (A v v Z J t IX W `J C p N N N O U mm m J Q Z m 0 m 0 m 0 t0 N n d N Q ._. O O 6 H 2 p z z m w m _ E m 3w m � 7 Z Z m `m N 0 Z c wO m� U a 3 w I E II U w 0 J 0 LL LL O Z D Y Q w a oQ O w } w J Q Z O H 0 r Y a w Ix J p CN n N O F U O O K CN w j a v O } Q C « a � C U W 'o oa cli N U o 0 _L ww n w C N N N LL LL c V 0 0 0 O C G N 16 t0 z M F W U f n n Icl O C � � N (� C C N � > > w c d w oa �� w Q U CJ r- N d LL LL O z D Y Q Way 0 W O� 2 1 Cw G J z O H U C > O c CIO IM w cc m m 0 �o ro 0 L Q � 0 o c Z on Q V z = x � oN U p O Y 0 O ] N II U G GoCO z L o o° FWc]. Up[� oaoo N W J ? CQ G W N O F- J Q H F J FO&w _p N O O O U O N F � v CO N W " U > C7 O } 0' c Q .m c '0 V N �a 0 o w N O O O N .U.. n n n LL w 0 0 0 Q � 6 L6 6 z D It W U Y U o 0 0 O O O O C N �_ c .0 Q y A � W Loa) w N Z U LL 0 E 0 w w w w L w y `CD m C .0 C N 0 C y Y f0 O m C pI 3 C C- U 11 II II C! U �I Q O_ d A 6 LL LL O Z Y Q_ a� 0 LU O I-- c W r C v J Z 0 H P N r F- IY W Z CQ G W N 0 J Q H (] F- J O C) M Q U v N N F � W ar O w LLj U > O LY � C Q ,L C v ('o oa o O N 7 V v U M N ui dv C W W W LL U. C 0 0 0 t6 16 vi Z 7 H W U o W n W N W U o 0 0 Q N N 6 O O O c N d N Q -E c N N W � C d d •N � C 'y S C .O d 0 3: w U LL 0 E 0 r-. y � y N M L Y m t c (D U O N l6 N U C a)_ 0)Y — N O (O C N n L II II II 0 U �I Q x 3 LL- II BOX CONDUIT (Normal:.8� Critical Depth Computation) °I Project: Buckingham Street Box ID: West sidewalk chase &concrete channel conduit invert slope Manning's n-value Width Height ign discharge area wetted perimeter capacity ial flow depth (<H ) area ad perimeter velocity large mt Full ial Depth Froude Number flow depth flow area flow velocity Depth Froude Number Y W H So = 0.0200 ft/ft n = 0.0130 W = 2.00 ft H = 0.50 ft Q = 3.10 cfs Af =1 1.00 Isq ft Pf =1 5.00 Ift Qf =1 5.54 cfs Yn An Pn Vn Qn Flow Fr, Yc = 0.42 ft Ac = 0.84 sq ft Vc = 3.68 fps Frc= 1.00 Westchannel.)dsm, Box 7/24/2015, 10:50 AM BOX CONDUIT:;FLOW (Normal 8r Critical.Depth Computation) Project: Buckingham Street Box ID: East sidewalk chase &concrete channel Y Box conduit invert slope So = 0.0100 ft/ft Box Manning's n-value n = 0.0130 Box Width W = 2.00 ft Box Height H = 0.50 ft Design discharge Q = 2.30 cis Full -flow capacity Calculated Full -flow area Af =1 1.00 Isq ft Full -flow wetted perimeter Pf = 5.00 ft Full -flow capacity Qf = 3.92 Jcfs Calculations of Normal Flow Condition Normal flow depth (<H) Yn = 0.28 ft Flow area An = 0.56 sq ft Wetted perimeter Pn = 2.56 ft Flow velocity Vn = 4.14 fps Discharge Qn = 2.30 cfs Percent Full Flow = 58.7% of full flow Normal Depth Froude Number Fr. = 1.38 supercritic Calculation of Critical Flow Condition J Critical flow depth Yc = 0.35 ft Critical flow area Ac = 0.69 sq ft Critical flow velocity Vc = 3.33 fps Critical Depth Froude Number Fr, = 1.00 East channel.)lsm, Box 7/24/2015, 10:51 AM Erosion and Sediment Control Escrow/Security Calculation for The City of Fort Collins Project: Buckingham Street- 1st to 3rd Disturbed Acres: 1.48 at�y'.Fk.M...,yP.�.teA.L..m.x..oru.^.."..n.. tsu'..3ilL+a».,"S;.�w'YSS.*di.*o� ,u.a»�a..ar...�xls,..+wrcLWixryY>:.""4n,a�r���-��.r�a�nfi.E..�.-�v®+...r...2:�'1•l"m} �.n_iM` 1 ' .m�a�aGeaL Estimated Unit Total EROSION CONTROL BMPs Units Quantity Price Price Rock Sock each 8 $85.00 $680.00 Concrete Washout each 1 $1,200.00 $1,200.00 Inlet protection each 2 $90.00 $180.00 (add all other BMPs for the site in this list) Sub -Total: $2,060.00 1.5 x Sub -Total: $3,090.00 Amount of security: $3,090.00 x "r s `.,4.Reseedina Amount .:. Y?$ gu �1 i 5, 3 f 3 Total Acres x Price/acre: $1,776.00 Unit Price of Seeding per acre: $1,200.00 Sub -Total: $1,776.00 1.5 x Sub -Total: $2,664.00 Amount to Re -seed: $2,664.00 �o- r _`__ ^ a Mgnumum EscrowAmo nt�._ :ti. Minimum escrow amount: $3,000.00 Erosion Control Escrow: $3,090.00 "The amount of the security must be based on one and one-half times the estimate of the cost to install the approved measures, or one and one-half times the cost to re -vegetate the disturbed land to dry land grasses based upon unit cost determined by the City's Annual Revegetation and Stabilization Bid, whichever is greater. In no instance, will the amount of security be less than one thousand five hundred dollars ($1,500) for residential development or three thousand dollars ($3,000) for commercial development" 7/24/2015 10:32 AM ui110-uBuckWr .D Dabmae,Ecesuow.a 0 STORMWATER MANAGEMENT CONTROLS 1. Written Analysis The soils on this site are classified by the USGS Soil Survey as Caruso Clay Loam and are classified in the hydrologic group D. The soils are described as having a very slow infiltration rate when thoroughly wet and the hazard of water erosion is moderate and the hazard of wind erosion is low. The site is a street widening on an existing street that is bordered on the south by .existing residential development and on the north by a landscaped detention pond. The construction shall utilize silt fence as needed (no shown on erosion control plan) to control sediment transport from rainfall and from wind. Rock socks will be utilized in the existing detention pond, around new sidewalk chases inlets and in the newly constructed concrete channel to capture sediments that are not fully contained by the silt fence placement. Sediment that is tracked onto existing pavements will be removed and placed within the site or permanently disposed of offsite. A concrete washout will be used on site during the concrete placement. All hardened concrete will be disposed of offsite. These BMP's have been located on the site map but may be located as construction dictates due to the fact that the site is very small and these BMP's will need to be placed by the contractor in locations that are most beneficial and will minimize disruption of adjacent traffic. Permanent erosion control consists of covering the soils with pavement, concrete walks and landscaping. No soil, will be left exposed to erosion after the construction is complete. Refer to the landscape plan for areas of and instructions for placement of sod/seed and soil amendments required prior to placement of sod. Refer to the erosion control plan for this site for the location of all BMP's for this site. Refer to the Erosion Control Surety calculations on the previous page. 2. SWW contact information Permit holder: Name: Address: Phone Number: Email Address: Appointed agent: Name: Address: Phone Number: Email Address: 3. Identification and location of all otential ollution sources r r� r�PotenhahPdllutantlSource Achvity� ;f y tk� Y> 'i:. t �'+ay r Potential Pollutant Generated » «,f� y` ur$i .i:l�. + .YhdS'�kF h�z 4.U+51 'F A hcable to pp a� �dj115 pIOject s Disturbed Areas Sediment X Soil stockpiles Sediment X Travel to adjacent public streets Tracked sediment X Contaminated soils Sediment, chemicals Loading and unloading chemicals Chemicals Unloading of building materials Trash, debris X Outdoor storage of chemicals Chemicals On site equipment maintenance Oil, grease On site equipment fueling Diesel, gasoline X Dust generating activities Particulates, sediment X Use of fertilizer, pesticides, herbicides Fertilizer, pesticides Use of detergents, solvents, oils Detergents, solvents, oil X Waste dumpsters, waste piles Chemicals, trash, debris X Concrete washout Concrete, sediment, wash water X On site equipment washing Detergents, oil On site asphalt batch plant Asphaltic cement, sediment On site concrete batch plant Cement, sediment Portable toilets Domestic sewage X 4. Best Management Practices (BMP's) for Stormwater Pollution Prevention Structural Practices for Erosion and Sediment Control Structural practices for the site will consist mainly of inlet protection and rock sock filters and are described in detail in the following paragraphs. These BMP's are expected to change as the construction progresses and it is the responsibility of the contractor to ensure appropriate BMP's are in place and/or removed at the appropriate time in the construction sequence. All temporary and permanent erosion and sediment control practices must be maintained and repaired as needed to assure continued performance of their intended function. Rock sock filters in the existing detention pond shall be in placed prior to commencement of construction activities. As construction allows, rock socks an&inlet filters will be placed on the street. During clearing and grubbing, all cleared material shall be placed on the uphill side so that if erosion occurs from the cleared material, the sediment will be trapped and not transported downstream. All BMP's shall be installed per the details shown on the construction plan set. Temporary & Permanent Structural BMP's:. •. 'i"�' S. t +� � v M �I Structural BM-t Y P r • .4 � 4 'i SR.. '�Y;,d[.. � �s.`a. 4 �a2 �". t�? `. z. `� .� P ° t w Approx�mate,locahon on situ < s y i t i; fy�A a..Ua� `-`aq •`tj r: Applicable to this )� Pro ect Silt Fence As needed, contractor to determine X Straw bale dams Rock Socks At new sidewalk culverts, in detention pond, in new curb, refer to site map X Earthen diversion dams Vegetated swales Rock Berm In existing det pond X Pipe slope drains Geogrid Inlet/outlet protection Culverts Riprap Erosion control mats Inlet protection Vehicle Tracking Control Pad Concrete Washout To be located by Contractor, near site entry X Non -Structural Practices for Erosion and Sediment Control: Soils exposed during the earthwork phase and landscape prep phase shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control is installed. No large amount of soils (in excess of 15 yards) will be allowed to be stock piled on site. Overburden from the utility pipe trenching will be piled adjacent to trenches upstream of sediment controls and will be replaced in the trenches within 72 hours. Excess excavated materials from the demolition and grading phases of the project that cannot be reused on site will be exported as it is excavated. This includes any asphalt pavement from the existing site that is to be removed. Vehicles will not be permitted in the excavated area if soil is muddy. Gravel sub base will be placed and compacted in the areas indicated for pavement following excavation. In the current pre construction state the site enables tracking of silt onto the adjacent streets during wet conditions. During construction activities the street will be monitored for foreign debris tracked out of the site and mechanical sweeping and clean up will be performed as needed. No area shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed. Temporary & Permanent non-structural BMP's: Non Structural BMP Approximate location `site s pP �� P ; f MY S:t. on a x � JProj&t t co%-f.-ti'4..K E3.. ..i+.`rt�.'. .4.nia.4tJu+:G;Y :"ito �-✓ ,1.: Y».v�'..:.»�c.+.iiPv'S.. W .',Fxy::: Surface roughening Entire site X Soil stockpile height limit (less than 10') Perimeter vegetative buffer North boundary of site X Minimization of site disturbance Mulch Seed & mulch stockpiles after 30 days Stockpile toe protection (silt fence, wattles or ditch) Preservation & protection of existing vegetation & trees North boundary of site X Good site housekeeping (routine cleanup of trash & constr debris) Entire Site X Sweeping & scraping of hardscape On and off site pavements X areas Heavy equip staged on site, properly maintained & inspected daily (no Staging area X onsite maintenance) 5. BW Implementation 1) Phased BMP Implementation BMP's are expected to change as the construction progresses and it is the responsibility .of the contractor to ensure appropriate BMP's are in place and/or removed at the appropriate time in the construction. sequence. A construction sequence schedule has been included on the Erosion Control Plan in the construction plans for this site. All BMP's shall be inspected and repaired or replaced as required to satisfy the conditions of the Stormwater Discharge Permit. All BMP's must be maintained and repaired as needed to assure continued performance of their intended function. Refer to Appendix D for the BMP schedule and estimated costs. 2) Materials Handling and Spill Prevention: Ivlatenals'Handlmg & Spills s y ximate loaton on sitegtil t€hiSs p&pott ° w.,, ci a eec cE2evnti M .liPc"ra'obl .� 9At ,' "t Portable toilets, anchored & located away from drainages Contractor to determine X Fuel storage located in bulk tanks with secondary containment & spill kit Mobile fueling performed at least 200 feet away from drainages. & Contractor to determine X fully attended Fertilizers, form oil, solvents, cleaners, detergent stored in 55 gal or smaller containers, kept in Contractor to determine X storage units Dumpsters containing used chemicals containers & liquid Contractor to determine X wastes kept covered Equipment cleaning (on site) uses no detergents & flows to onsite retention basin In case of a release of fuel or other chemicals, absorbent booms or earthen berms will be immediately constructed to contain the spill & Location of spill X prevent runoff to adjacent surface waters MSDS sheets for onsite chemicals will be kept at the construction Contractor to determine X trailer to facilitate spill response & cleanup 3) Dedicated Asphalt or Concrete Batch Plant: Not proposed with this development 4) Waste Management and Disposal: Portable toilets will be anchored & periodically maintained by waste management company. Dumpsters on site will be covered & periodically emptied by waste management company. Concrete waste Will be allowed to harden and then will be removed from site. No washing activities will occur on site. 40 Location of the concrete washout is shown on the site map. The washout will be sufficiently deep to accommodate all anticipated concrete truck wash water. Waste concrete will be allowed to harden and be removed from site periodically as the washout reaches 50% of its capacity. Truck wash water will not be allowed to reach the curb & gutter or any other water course. . 5) Groundwater and Stormwater Dewatering: No groundwater was encountered during soils exploration therefore ground water is not anticipated to be an issue. If groundwater is encountered a groundwater discharge permit shall be obtained and a detailed report shall be completed describing the location and the route of where pumped groundwater will be conveyed and the measures taken to prevent the transport of any pollutants to downstream waters. 6) Inspection & Maintenance: It is required that routine site inspections are performed to effectively address maintenance and repair of Best Management Practices (BMP's). The site inspections are to be performed by the contractor or an inspector designated by the administrator at a minimum of once every fourteen (14) calendar days on active construction sites and after any significant storm event (an event causing runoff). As part of the site inspections the inspector is required to keep documentation of all inspections and BMP maintenance, including an updated Site Map indicating new BMP's or the removal of BMP's since the previous inspection. Any maintenance, repair, or necessary installation of BMP's that are noted during the inspection must be completed within seven (7) calendar days from the date of the inspection No Text FINAL DRAINAGE AND EROSION. CONTROLSTUDY NEW BELGIUM BREWERY, FOURTH FILING PACKAGING HALL & BUCKINGHAM STREET IMPROVEMENTS Prepared for: New Belgium Brewery 500 Linden Street Fort Collins, CO 80524 Prepared by: North Star Design 700 Automation Drive, Unit I Windsor, Colorado 80550 (970)686-6939 June 12,.2006 Job Number 110-13 i Eli 9Af i .. fly a II^jJ Ijf �I� P JIM I III Awl 111 ;1111 fill IMIIAII! q in�d�un- unlnuu nunYnli lannln IR nr..... r.a ' 11�111�'llll IhIIIIItIL 1 PACKAGING HALL & BUCKINGHAM STREETIWROVEMENTS OVERALL DR.NAcr PLAN br rs x t � e yx CAM North Star tlasl9R Ix no.umra dn.. w 1 ww.s, o�.ro rom real omaesnm re amw.un ch O W IL a) i � � a m W x m LL W a Z U L.L 3 E LL u � y O •Z .m o M o � CL at) •` m U m o, U c � •m i U ❑ c c y >> • O m � �4�w Em I. O O C m m c i D a 0 0 o ocpoo C mp) vCL C) E C 0 U v V 0 0 C3 n O o c o o c U N 10 0 n O N 0 A 0 b O O a 0 0 0 b O N I^p N A m b O E E LL LL O LL �. Z {�I U Q 0 N 0 0 1` 0 R b N b Q 0 m N 0 0 0 0 O 0 b b G G O O O G O O O C G G K Col a a¢ o 0 0 0 o m o p o o m a N Cr0 N m 0 Q J > w n n Q¢¢ o o m o o a o O a K ow c o n oa o a m P o b o coo 0 K < N 17 P Q C U X Q O v m N O n o o O O O � o p 1 O m Zo Q U a¢ C 0 0 0 0 0 0 O R Q d x u m m m o uoi w^i c N 0 a ooi t7 w �- h Q rl r m b ON) T Q 00 T F W C O Q N O O n tpp W O b y O O N J LQ J-0 F W o Q .W. � mN Ci m� C m O t7 10-0-- L;- N N z z O mQ c Z m 0 N (7 Q m m n m w w O ffi LL Y. O Z Y LU o w O �- = O W m a Z a O ~ 3 N m b O O � 3 N � II' U h O 7 � m z z� wo H N p ro m a 0 ..70w0A L _C Z `din 7i I ' a m 0 a E m c a m in m ❑ m ❑ c d m o N m Q U❑ � p W W m o Y a E E m s LL W �00 NNf� ❑f4 to co K Fm- H 0 F F0 0- F O F `o e � mNomMrIN� my. ro Q Q H O O u O O > E c O 0 a . `o U Q N M n IA N Q r N N ro O N N - C ro tq m N O M ro N m Ol ^ O a rommr:rimm id mi o of ec tc U oo�n o o rn pi tQ m o r ro W. �- O a a G O 0 0 0 00 0 O r _ C. ,- ._ . nm W.0Q w;-0 :-M m 0 (7 G ifI n LL LL Z m O m 7 as �NMQIAroan W W O U ~ F U N m F K O r a � o .-NM QIA W 0. O a 9 North Star Design 700 Automation Drive. Unit I - Windsor, SO 80550 MAIN SITE MINIMUM DETENTION_. VOLUME_ REQUIRED FAA METHOD (100-YEAR) LOCATION: NBB - Bottling Hall PROJECT NO: 110-13 COMPUTATIONS BY: PPK SUBMITTED BY: North Star Design, Inc. DATE: 6R2006 Emiations: QD = CiA Vi = T*CiA = T*% V,=K*QPo*T S=Vi-V* Rainfall intensity from City of Fort Collins IDF Curve A trib. To pond = 18.10 acre C100 = 0.69 Developed C*A = 12.5 acre QPo = 1.15 cfs K = 1 (from fig 2.1) Storm Duration, T (min) Rainfall Intensity, i (in/hr) QD (cfs) V01.In Vi (ft) Vol. Out V. (ft) Storage S (fr) Storage S (ac-ft) 5 9.95 124.3 37280 345 36935 0.85 10 7.72 96.4 57849 690 57159 1.31 20 5.60 69.9 83926 1380 82546 1.89 30 4.52 56.5 101611 2070 99541 2.29 40 3.74 46.7 112101 2760 109341 2.51 50 3.23 40.3 121018 3450 117568 2.70 60 2.86 35.7 128587 4140 124447 2.86 70 2.62 32.7 137429 4830 132599 3.04 80 2.38 29.7 142674 5520 137154 3.15 90. 2.22 27.7 149718 6210 143508 3.29 100 2.05 25.6 153615 6900 1 146715 3.37 110 1.93 24.1 159085 7590 151495 3.48 120 1.80 22.5 161857 8280 153577 3.53 130 1.60 20.0 155863 8970 146893 3.37 140 1.40 17.5 146871 9660 137211 3.15 150 1.20 15.0 134881 10350 124531 2.86 160 1.15 14.4 137879 11040 126839 2.91 170 1 1.10 13.7 140127 11730 128397 2.95 180 1.05 13. 1 141625 12420 1 129205 2.97 Required Storage Volume: 153577 fe 3526 acre-ft DetPond - all onstte.:ds ��Se ^Ti'�E!et�V! ve Me,vfiS FAA all (100yr) W N ,V5 0 z 0 a F V LU MM W y� CD G O i z G] w 0 o_ moPC 0 a z �o m .a�i U 0) ca 1^ O W e ca v o F E oaUU�A li m c a m 7 C � �N } N c T 0 c rn i� O 0 D d k - C n 3 + o + w « u T c Y m � E 7 O `O Y / Q d I I d E d m m U � o O (n 10 7 d d 0 0 Cr 0 4) w 1/ V N Y P s 3 3 N N N O V' Q r T m II II II � II Z Q � O C � cp O O R N a 4 L E m W Q# O Q n O) 0: � C m f0 0 O 'N O L m 4 E N O) 0 7 tL v o L ro . m c 0 U U 7 m c 0 U U 7 North Star Design 700 Automation Drive, Unit I Windsor, SO 80550 STAGE - STORAGE TABLE (10 & 100-YEAR) LOCATION: NBB - Bottling Hall PROJECT NO: 110.13 COMPUTATIONS BY: PPK SUBMITTED BY: North Star Design, Inca DATE: 6=06 Water Quality Volume Required = 0.323 ac-ft 100 yr Detention Volume Required = 3.526 ac-ft ONSITE POND WQCI 100 WSEL / SPILL WAI DetPond - all onsite.ais Stage (ft) Surface Area (ftZ) Incremental Storage (ac-ft) Total Storage (ac-ft) 4946.0 0 0.000 0.000 4947.00 16025 0.123 0.123 4947.44 24042 0.200 0.323 4948.0 34310 0.374 0.697 4949.0 56800 1.035 1.732 4950.0 85650 1.624 3.356 4950.09 86891 0.170 3.526 4951.0 100080 2.130 5.486 ha5e -�I' Stage -Storage - Onsite North Star Design 700 Automation Drive, Unit I Windsor, SO 80550 t! i y DefPond - an onsitexis (100 yrevent) LOCATION: NBB - Bottling Hall PROJECT NO: 110-13 COMPUTATIONS BY: PPK SUBMITTED BY: North Star Design, Inc. DATE: ' 6/2/2006 Submerged Orifice Outlet: release rate is described by the orifice equation, Q. = CA sgn(2g(h-E )) where Q, = orifice outflow (cfs) C. = orifice discharge coefficient g = gravitational acceleration = 32.2 ftrs A. = effective area of the orifice (ft?) E, = greater of geometric center elevation of the orifice or d/s HGL (ft) h = water surface elevation (ft) ONSTTE POND Q,,, = 1.15 cfs outlet pipe dia = D = 12.0 in Invert elev. = 4946.00 ft E, = 4946.20 ft h = 4950.09 ft -100 yr WSEL C, = 0.64 solve for effective area of orifice using the orifice equation A,= 0.114 if 16.4 in= orifice dia. = d = 4.56 in Check orifice discharge coefficient using Figure 5-21 (Hydraulic Engineering) d/D= 0.38 kinematic viscosity, v = 1.22E-05 ft"Is Reynolds no. = Red = 4Q/(pdv) = 3.16E+05 = (K in fie) = CoffD 0.64 check Use A16.62 in2 Q Pk0i 5c -I— C v6Tj Y&C otnFice, S(ae orifice Onsite -100yr North Star. Design 700 Automation Drive, Unit I Windsor, SO 80550 Emergency Overflow Spillway Sizing LOCATION: NBB -.Bottling Hall PROJECT NO: 110-13 COMPUTATIONS BY: PPK SUBMI= BY: North Star Design, Inc. DATE: 8/9/2005 Equation for flow over a broad crested weir _ top of berm Q = r4 �— L —i spill elevation where coefficient C = weir eent = 2.6 H = overflow height p i110 K WSEL L = length of the weir The pond has a spill elevation 0.55 ft above the maximum water surface elevation in the pond Spillways will be designed with 0.5 It flow depth, thus H = 0.5 It Size the spillway assuming that the pond outlet is completely dogged. Q (100) = 20.00 cfs Q(100)= 2 times the flow rate entering Spill elev = 4950.09 ft the brim full pond assuming no release Min top of berm elev.= 4950.59 Weir length required: 100 yr WSEL = 4950.09 ft L = 22 ft Use L = 30 ft v = 1.55 ft/s DefPond - a8 onsde.As hose S Pt t'QCA L Spillway - Onsite