Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutDrainage Reports - 05/09/2014City of Ft. Collins veA Plans
Approved By
Date__
FINAL DRAINAGE REPORT
MVG-MORNINGSTAR
ASSISTED LIVING & MEMORY CARE
Prepared by:
Interwest Consulting Group
1218 West Ash, Suite C
Windsor, Colorado 80550
(970)674-8488
Prepared for:
MVG — MS (Fort Collins) LLC,
A Colorado Limited Liability Company
c/o MVG Development
1509 York Street
Denver, CO 80206
April 23, 2014
Job Number 1173-105-00
t
I
INTERWEST = CONSULTING G R O U P
April 23, 2014
Mr. Wes Lamarque
' City of Fort Collins Stormwater
700 Wood Street
Fort Collins, CO 80522-0580
RE: Final Drainage Report for MVG-Morningstar Assisted Living & Memory Care
Dear Wes,
' I am pleased to submit for your review and approval, this Final Drainage Report for the MVG-
' Morningstar Assisted Living & Memory Care development. I certify that this report for the
drainage design was prepared in accordance with the criteria in the City of Fort Collins Storm
Drainage Manual.
I appreciate your time and consideration in reviewing this submittal. Please call if you have any
questions.
' Sincerely,
O�p0 RE(3 j r�
l •°C 33441 jr
iQ
Robert Almirall, P.E. O�.''••...... ..••'' '+
Colorado Professional ss/ONALO
' Engineer No. 33441
L
1
C
' 1218 WEST ASH, SUITE C WINDSOR, COLORADO 80550
EEI. 970.674.3300 - fez. 970.674.3303
'
TABLE OF CONTENTS
TABLEOF CONTENTS............................................................................................................iii
1. GENERAL LOCATION AND DESCRIPTION................................................................
1
t
1.1 Location...........................................................................................................................1
1.2 Description of Property.................................................................................................
1
2. DRAINAGE BASINS AND SUB-BASINS..........................................................................
2
2.1 Major Basin Description................................................................................................
2
'
2.2 Sub -basin Description....................................................................................................
2
3. DRAINAGE DESIGN CRITERIA
'
3.1 Regulations ................. ..............:........................................................................
2
3.2 Development Criteria Reference and Constraints......................................................
2
3.3 Hydrological Criteria.........................................................................
............................ 4
'
3.4 Hydraulic Criteria..........................................................................................................
5
3.5 Floodplain Regulations Compliance.............................................................................
6
'
4. DRAINAGE FACILITY DESIGN.......................................................................................
6
4.1 General Concept.............................................................................................................
6
' 4.2 Specific Flow Routing.................................................................................................... 6
4.3 Drainage Summary........................................................................................................
' 5. CONCLUSIONS....................................................................................................................8
5.1 Compliance with Standards.......................................................................................... 8
5.2 Drainage Concept........................................................................................................... 8
6. REFERENCES..............................................................................................................:....... 8
' APPENDIX
VICINITY MAP AND FLOODPLAIN MAPS.......................................:................................. A
' HYDROLOGIC COMPUTATIONS..........................................................................................B
HYDRAULICCOMPUTATIONS..............................................................................................0
WATERQUALITY..................................................................................................................... D
t
iii
1 1.
GENERAL LOCATION AND DESCRIPTION
1.1 Location
The MVG-Morningstar Assisted Living & Memory Care development is located in
southeast Fort Collins. It is located in the Southwest Quarter of Section 30, Township 6
North, Range 68 West of the Sixth Principal Meridian, in the City of Fort Collins,
Larimer County, Colorado. See the location map in Appendix A.
' The project is located west of Lochwood Drive, north of E. Horsetooth Road, and
bounded on the west and north sides by existing residential lots. An existing drainage
ditch with an existing 25 ft Drainage Easement runs along the west edge of the property,
tdividing it from the residential properties.
' 1.2 Description of Property
The property consists of approximately 4.42 acres of land. The existing land currently
drains from southeast to northwest at approximately a 2% grade. The land is currently
vacant with mild sloping terrain and covered with natural dry -land vegetation across the
' entire site. The only offsite flow entering the site is through an existing concrete drainage
ditch originating at the Southwest corner of the property and conveys runoff to the
' northeast. There is an existing 25' drainage easement accompanying the existing
concrete ditch, extending from the existing flowline 25' to the west. An additional 25'
' drainage easement is proposed, extending from the flowline 25' to the east, to make the
entire Drainage Easement 50' wide up to the Tract A -Utility & Drainage Easement. The
channel is not mapped by FEMA, but the project is located in Zone X of FEMA FIRM
' Panel 08069C 1000F.
The Geotechnical Report and Supplemental Memorandum by Kumar and Associates
dated November 12, 2013 and December 10, 2013, respectfully, indicate the presence of
' groundwater at approximate depths of 8 to 9 feet below existing grade. However, based
on the recommended drilled pier design, a building perimeter drain system is not
required.
The poorly draining onsite materials do present the need for a supplementary underdrain
' system for the proposed site LID's.
' 1
u
' 2. DRAINAGE BASINS AND SUB -BASINS
' 2.1 Major Basin Description
' The proposed development lies within the McClelland's Creek Master Drainage Basin.
The entire site currently drains to an existing concrete drainage ditch along the west and
northwest property boundary. James H. Stewart and Associates performed a drainage
' study on this drainage in March of 1978 and determined the 100-year storm to produce
217.0 cfs. However, the updated 2010 SWMM model for the basin shows a 2-year storm
' run-off of 20.6 cfs and a 100-year storm run-off of 150.2 cfs. See Appendix B for
existing site hydrologic computations.
2.2 Sub -basin Description
' The existing site has a historic runoff of 1.7 cfs and 6.7 cfs for the 2-year & 100-year run-
off event, respectively, with a historic 2-year release rate of 0.39 cfs/acre. The site will be
' divided into 2 sub -basins for proposed construction activities. Sub -basin A will consist
of approximately 1.24 ac and will be collected in a small extended detention basin located
' southwest of the proposed building before releasing into the existing drainage ditch to the
west. Sub -basin B consists of approximately 3.18 ac and drains to the northwest corner
' of the property where it will be collected in a second extended detention basin before
releasing into the existing concrete drainage ditch west of the property. Once the run-off
enters the existing ditch, it will flow northeast eventually reaching McClelland's Channel.
3. DRAINAGE DESIGN CRITERIA
3.1 Regulations
' This report was prepared to meet or exceed the "City of Fort Collins Storm Drainage
Design Criteria Manual" specifications. Where applicable, the criteria established in the
' "Urban Storm Drainage Criteria Manual" (UDFCD), developed by the Denver Regional
Council of Governments, has been used.
3.2 Development Criteria Reference and Constraints
' Urban Drainage and Flood Control District (UDFCD) recommends a Four Step Process
1 2
for receiving water protection that focuses on reducing runoff volumes, treating the water
quality capture volume (WQCV), stabilizing drainageways and implementing long-term
source controls. The Four Step Process applies to the management of smaller, frequently
occurring events.
Step I: Employ Runoff Reduction Practices
To reduce runoff peaks, volumes, and pollutant loads from urbanizing areas, implement
Low Impact Development (LID) strategies, including Minimizing Directly Connected
Impervious Areas (MDCIA). See the LID Area Exhibit in Appendix D.
' Runoff for the site will be split around the proposed building's southeast corner to the
' west and north, respectively.
Sub -Basin A
' Runoff directed to the west will be routed south of the building through a Grass Swale to
an extended detention basin, herein referred to as "Extended Detention Basin A"
equipped with a Water Quality Outlet Structure which will release flow into the existing
' concrete drainage ditch along the west edge of the property. Extended Detention Basin A
will also be constructed with Gravel Dry Wells along the flow line of the basin to help
slow the basin's time of concentration and serve as supplemental Low Impact .
Development (LID) measures.
Sub -Basin B
Runoff directed to the north will be routed through another Grass Swale thereby reducing
' runoff from impervious surfaces over permeable areas to slow runoff and increase the
time of concentration and promote infiltration. Runoff from portions of the parking lot
shall drain across Pervious Pavers before entering a second extended detention basin,
' herein referred to as "Extended Detention Basin B".
' Step 2: Implement BMPs that Provide a Water Quality Capture Volume with Slow
Release
' Sub -Basin A
Extended Detention Basin A utilizes a Grass Swale, Gravel Dry Wells and a Water
Quality Outlet Structure designed to allow sediments to settle while releasing treated
' flows at or less than historic rates.
Sub -Basin B
' A Grass Swale located southeast of the main building entrance shall collect the down-
' 3
I
' spout runoff before conveying the water to the second water quality treatment basin.
Pervious Pavers are located within Sub -basin B upstream of Extended Detention Basin B
' to help reduce total runoff by allowing water to infiltrate. Extended Detention Basin B
also shall be equipped with a Water Quality Outlet Structure designed to allow sediments
' to settle while releasing treated flows at or less than historic rates.
' Step 3: Stabilize Drainageways
Natural Drainageways are subject to bed and bank erosion due to increases in frequency,
duration, rate and volume of runoff during and following development. Concrete pans
' shall be used to convey water from the paved and parking areas to Extended Detention
Basin B. A concrete pan shall also be used at the outlet of Extended Detention Basin A
' and a concrete channel will be used at the outlet of Extended Detention Basin B. Rip
Rap shall be used at the outlet of the on -site storm sewer system. The Rip Rap shall be
' stabilized in place.
Step 4: Implement Site Specific and Other Source Control BMPs
' Proactively controlling pollutants at their source by preventing pollution rather than
removing contaminants once they have entered the stormwater system or receiving waters
' is important when protecting storm systems and receiving waters. . This can be
accomplished through site specific needs such as construction site runoff control, post -
construction runoff control and pollution prevention / good housekeeping. It will be the
responsibility of the contractor to develop a procedural best management practice for the
' site.
' 3.3 Hydrologic Criteria
Runoff computations were prepared for the 2-year and 10-year minor and 100-year major
' storm frequency utilizing the rational method. The Modified FAA method was used to
determine preliminary detention volumes for the proposed extended detention basins.
' All hydrologic calculations associated with the basins are included in Appendix B of this
report. Sub -Basin A will encompass 1.24 acres, 38% of which will be impervious, and is
tcalculated to have 2-year, 10-year, and 100-year discharges of 1.0, 1.7, and 4.5 cfs,
respectively. Sub -basin B will encompass 3.18 acres, 47% of which will be impervious,
' and is calculated to have 2-year, 10-year, and 100-year discharges of 2.9, 4.9 and 12.5 cfs,
respectively.
' 4
' The water quality storage volumes in Sub -basin A and Sub -basin B were calculated to be
' 0.02 ac-ft and 0.06 ac-ft, respectively.. Water quality volumes for both basins shall be
provided in the proposed designs of Extended Detention Basins A and B. Final water
' quality volumes are presented in the Appendix D and calculated using the method
recommended in the "Urban Storm Drainage Criteria Manual".
' 3.4 Hydraulic Criteria
' Using methods described in the City of Fort Collins Drainage Criteria, it was determined
that Sub -basins A and B are required to detain 0.11 and 0.36 ac-ft respectively, in
' addition to the water quality volumes referenced in section 3.3 of this report.
Sub -Basin A
The proposed Extended Detention Basin A meets the water quality requirement for
' storage at elevation 4968.50 and the 100-yr storm detention at elevation 4969.70. A 5
foot long spillway shall be constructed at elevation 4969.80. A water quality outlet
' structure shall be utilized in releasing flows at or below historic rates into an 18" RCP
culvert that shall discharge into a proposed concrete pan before entering the existing
' concrete channel along the west boundary of the site.
Sub -Basin B
' Runoff from the existing adjacent roadways shall be collected in a proposed Type `R'
Inlet along Lochwood Drive, south of the northernmost Morningstar site access. This
runoff will be piped in 18" and 24" RCP pipes in the site's storm drain system to the
' Extended Detention Basin B. Downspout runoff from the southeast portion of the
building as well as that runoff adjacent to the southeast portion of the building will be
' collected in a small proposed rain garden infiltration area before entering the site's storm
drain system. Runoff from the parking areas and the runoff adjacent to the northeast,
' north, and northwest sides of the building shall sheet flow overland toward Extended
Detention Basin B.
tThe proposed Extended Detention Basin B meets the water quality requirement for
storage at elevation 4964.50 and the 100-yr storm detention at elevation 4967.00. A 13
' foot long spillway shall be constructed at elevation 4967.10. A water quality outlet
structure shall be utilized in releasing flows at or below historic rates into a 24" RCP
' culvert which shall discharge into a proposed concrete' channel before entering the
existing concrete channel to the northwest of the site.
' 5
L
All hydraulic calculations are presented in Appendix C and prepared in accordance with
' the City of Fort Collins Drainage Criteria.
' 3.5 Floodplain Regulations Compliance
' No work is proposed within an existing floodplain.
4. DRAINAGE FACILITY DESIGN
4.1 - General Concept
The proposed MVG-Morningstar site was designed to treat run-off as close to the point -
source as possible, while also minimizing the length of drainage routing to the most
' feasible extents of the site.
' The proposed site shall be divided into two sub -basins based on design points A and B.
The proposed drainage design follows the existing drainage pattern of southeast to
t northwest. The project will consist of an Assisted & Memory Care Complex building
with a footprint of approximately 43,000 SF, a parking area for patients and employees,
an access lane, sidewalks and landscaped areas. Proposed- site run-off is directed to a
' . series of LIDs and an extended detention basin at one of the two design points before
being released off -site. Each extended detention basin shall be equipped with a Water
' Quality Outlet Structure, designed specifically for that sub -basin, to treat and release the
run-off into the existing concrete ditch at or below historic run-off rates.
' Both of the extended detention basins serving as water quality basins shall also act as on -
site detention areas for the proposed construction. The on -site detention shall hold the
proposed 100-year run-off and release it at the historic 2-year storm release rate.
4.2 Specific Flow Routing
' A summary of the drainage patterns within each basin is provided in the following
paragraphs.
' 6
L
'
Sub -Basin A includes the southern portion of the property, excluding the existing
drainage ditch, and the south half of the downspouts from the proposed building, and is
'
approximately 1.24 ac. From the downspouts, flow will be routed through vegetated
areas carrying flow away from the building or sheet flow over -top the sidewalk.
'
Remaining Sub -basin A flow will be collected and routed through a Grass Swale along
the south edge of.the property and two (2) Gravel Dry Wells in the bottom of.the
'
Extended Detention Basin A, which is located just southwest of the proposed building.
Once the run-off is treated, the outlet structure discharges into the existing concrete
channel to the west of the site, eventually reaching McClelland's Channel. Sub -Basin A
'
is calculated to have a 2-year, 10-year, and 100-year discharges of 1.0, 1.7, and 4.5 cfs,
respectively.
'
Sub -Basin B includes the remaining approximately 3.18 acres located northeast of Sub -
basin A within the site, including the north half of the proposed building downspouts. A
portion of the east side building down -spout run-off as well as that immediately adjacent
to the southeast side of the proposed building will be collected in a proposed Grass Swale
'
before entering the site's private storm drain system. The north side building down -spout
run-off as well as that immediately adjacent to the north, northeast, and northwest sides of
'
the building shall sheet flow to the northwest to the proposed Extended Detention Basin
B. Parking and access road run-off will sheet flow to the northwest or enter the site's
'
storm drain system, which also drains into Extended Detention Basin B. Several rows of
spaces are proposed to be constructed with Pervious Pavers to treat small areas of
parking
runoff. Once the flow reaches Extended Detention Basin B they are again treated and
'
released through a water quality outlet structure into the existing drainage ditch flowing
northeast into McClelland's Channel. Sub -basin B is calculated to have a 2-year, 10-year,
'
and 100-year discharges of 2.8, 4.8 and 12.3 cfs, respectively.
'
4.3 Drainage Summary
The percent impervious weighted average of the entire site is 48.7%. All proposed site
runoff follows existing drainage flow patterns while adding a level of water quality to the
'
discharge.
Drainage facilities located outside of the right of way (including the rain garden, water
'
quality pond, proposed storm sewer system and the detention basin outlets) will be
7
' maintained by the owners of the property. The property owner shall also be responsible
for. maintaining the portion of the common drainage channel located on the subject
' property.
5. CONCLUSIONS
' 5.1 Compliance with Standards
' All computations that have been completed within this report are in compliance with the
COFC Storm water Criteria Manual, the COFC Master Drainage Plans, and the COFC
' floodplain regulations. All floodway information is in compliance with Chapter 10 of the
City of Fort Collins Municipal Code and all State and Federal regulations.
' 5.2 Drainage Concept
' The proposed drainage concepts presented in this report and on the construction plans
adequately provide for stormwater quantity and quality treatment of proposed impervious
' areas. Conveyance elements have been designed to pass required flows and to minimize
future maintenance.
' If, at the time of construction, groundwater is encountered, a Colorado Department of
Health Construction Dewatering Permit will be required.
' 6. REFERENCES
1. City of Fort Collins, "Storm Drainage Criteria Manual", (SDCM), dated March,
' 1986.
2. Urban Drainage and Flood Control District, "Urban Storm Drainage Criteria
Manual", Volumes 1 and 2, dated June 2001, and Volume 3 dated September
' 1999.
3. ICON Engineering, Inc., "McClelland's Creek Master Drainage Plan Update",
' dated November 20, 2000 (Revised March 2003).
4. Kumar & Associates, Inc., "Geotechnical Engineering Study Proposed MVG-
8
Morningstar Assisted Living and Memory Care Facility Northwest Corner of East
Horsetooth Road and Lochwood Drive, Fort Collins, Colorado' dated November
12, 2013 and a Supplemental Memorandum December 10, 2013.
Lt
APPENDIX A
VICINITY MAP, AND FLOODPLAIN MAPS
A
SECTION
36
re I
Wn go-go
WE
Es
WIN Hill■
■� Ism IN M
is aI
o 1 l :I
ml
COLUNDALE GOLF COURSE
�IIm1lllllll
�� •• mill
going
■ 1 ■ i� �i i
' IIII111III�on m
_._ -' ..1._�.�..w�� __.�..... a ._ofi.!i ._•- �, lam i_�.
MVG MORNINGSTAR m VICINITY MAP
SCALE: i "=1000`
t
1
Y
Y
O
Cr
g N bLL$QO� y
C N N m
Y Y m
W v Ccl
—_ —
Lm a a
W
_ n m T,
m m
V J Q J
U
0 '• Y
a Z U
d
3 M1 L
LL
p�
C
Y
to
mma a
LU
W
Ra
U p v
H
(•_..y
N d
m
ct
y■ QlL
co
m `p
W
} W
g m
a
�6 T
la
i9
w '-
� nnrwa
m c �.
a M \ as »` ��.
� v.n-•-,
= m E
�rn ui 2
..
N
EL
Lli
!.-
.I bs
a
N
fL
7
p ga
m E
E c
�v 3
d
w R
J
fl Jn
pf P
1
ern _
—
C
-
�
a
N
o
i
sarwsr , a
r
j
3
CL
-
Tl�l...
L
L
cb
aG
m
t� N
C
�
nl to
U
i
N p
o � U
APPENDIX B
HYDROLOGIC COMPUTATIONS
I
I
I
I
i
\
I
I
I
/
I
I
I I
4
111
l i y
I
I
I
I
I
I
I
I
DRAINAGE SUMMARY TABLE
l
CALL UTILITY NOTIFICATION
CENTER OF COLORADO
811
GALL 2-BUSNESS DAYS IN ADVANEE
BEFORE YW DIG. GRADE. DR EXCAVATE
FM THE MMXING M UNOERGRMIND
MEMBER UMTMS.
40 20 0 40 SO
SCALE: I"= 40'
LEGEND
EXISTING MINOR COWOIAR
'� EXISTING MAJOR CONTOUR
�wA�w. PROPOSED M INOR CONTOUR
�NIAIHr PROPOSED MAIOR CONrd1R
PROPOSED DIRECTION OF OVERLAND FLOW
PROPOSED DRAINAGE
BASIN DMDE LINE
A DRAINAGE BASIN ID
MAJOR STORM RUNOFF COEFFICIENT
DRAINAGE BASIN AREA ACRES
CONSTRUCTION ENTRANCI
O
EF` SILT FENCE
p_I 1
P_2 O BTORM DRAIN INLET. PN� U - I
EXTENDED DETENTNDN( MMEWATION
BASIN) INLET PROTECTION
WATTLE
(SWALE.O CH. OR VEGETATED FLO UNI
WATTLE
(GUTTER PROTECTION)
NOTES:
). SEE DETAIL SHEET 5IDT-5) FOR SPILLWAY CROSS SECTIONS
CONSTRUCTION SEQUENCE
STM Fa C
PRQkCi NYi+Man�aNemm On6K99N liwa Ram
COYPIFTED BY W MiE P,Yi.Y
INfYld usetln bu lrnnSYmpyS Nw�ao�m[Wtlm�suesNmnsYN Yp vyYlnloc TON
cPom scow! ^W ,4lnSWnn°9! rw SON4kI W� N pe 011 Fglnw
YONM
4
5
E
11T
8
9
ID
1 11
1 12
1 1
1 2
1D
mamem
6aI
FM.41Y
IU
��
vq�YNaE
s,.1loYYF
GOP
TT.,.., TYRB.9a
w a..:
[B eB.ntrs
BnOB�
Ben San FrelniLm
Tmwry
ASMMYCa.ree Pnnp
-
FY11Y1a�s.m lANnp
'_-
YY[IYy5a411
=
Tay01ry 6YEFi�Iry
SNMFIYIVI
NMBgJYYSAYYAa.
tlLY
DNG WISIRIKIION
Z
a
[� O F
p } UI I
w 7 iLLd
IGL .j a 0 OD
°w U ]wY0
tt O U
R �OUIr
C LL J O m>
O
a m.i 00
NE
V Q U
S` U
a
S � r
v
cc= m
aa�O
o
�EMrs�
low,
JOlML
w.qn
FtlM
YAMNIYY
ftb .w
An.
IK)
cpl
c110)
c(1M)
kDl
O.YI
.001
In MI
w(Ial
InInI
g2Ao1
Id.l
gNpa1
feh)
g1MM.1
Id.l
A ISWj
AISvO
IN
OH
0]0
DH
120
120
114
10
tT
45
R (NV/I
BBAVj
]t!
010
016
0'2
Ht
141
141
20
48
123
BMU,'INEB �A11EDBY. Sim MAIIW w Ivy
VEGEYATONTIIAOMO DONMA m TO RTBIV•I®BY ®BY BD
mm SA311, ED MPROV®BY LNAEB OdNtt b1
PROJ-NO. 11 7810600
9
1
1
1
1
1
1
1
1
1
1
1
1
Table RO-11
Rational Method Runoff Coefficients for Composite Analysis
Character of Surface
Runoff Coefficient
Streets, Parking Lots,
Drives:
Asphalt
0.95
Concrete
0.95
Gravel
0.5
Roofs
0.95
Recycled Asphalt
0.8
Lawns, Sandy Soil:
Flat <2%
0.1
Average 2 to 7%
0.15
Steep >7%
0.2
Lawns, Heavy Soil:
Flat <2%
0.2
Average 2 to 7%
0.25
Steep >7%
0.35
(4) A new Section 2.9 is added, to read as follows:
2.9 Composite Runoff Coefficient
Drainage sub -basins are frequently composed of land that has multiple surfaces or zoning
classifications. In such cases a composite runoff coefficient must be calculated for any
given drainage sub -basin.
The composite runoff coefficient is obtained using the following formula:
Y,(C, * A;
A,
Where: C = Composite Runoff Coefficient
C; = Runoff Coefficient for Specific Area (A)
A; = Area of Surface with Runoff Coefficient of C;, acres or feet-
n = Number of different surfaces to be considered
At= Total Area over which C is applicable, acres or feee
(5) Anew Section 2.10 is added, to read as follows:
41
(RO-8)
RAINFALL INTENSITY -DURATION -FREQUENCY CURVE
10.00
9.00
8.00
M
0 7.00
m
L
c 6.00
i 5.00
W
f
2 4.00
J
Q
i 3.00
Q
K
2.00
1.00
000
0.00 10.00 20.00 30.00 40.00 50.00
STORM DURATION (minutes)
2-Year Storm - - - 10-Year Storm 100-Year Storm
Figure RA-16 City of Fort Collins Rainfall Intensity -Duration -Frequency Curves
(13) Section 5.0 is deleted in its entirety.
(14) Section 6.0 is deleted in its entirety.
(15) Section 7.0 is deleted in its entirety.
(16) Section 7.1 is deleted in its entirety.
(17) Section 7.2 is deleted in its entirety.
(18) Section 7.3 is deleted in its entirety.
(19) Section 8.0 is deleted in its entirety.
(20) Table RA-1 is deleted in its entirety.
all
60.00
k
L °
& /—
k
�\
§
(\
E
F(
k
/
\�
z \
k5
(/ =
kR
)E
;AI§
(j
§a
.
e£
/
\\
$&
22
(wE
\\
\)/§
cc!
£
)
K/
a\
q»
2«�
(§\
\\
.
(k\
(k
§§
!«
. /
f
\
.
\■k
/)]\.
;%|—
®
�0
#
\))a
\}/\
\
\
/\kk
0.5
E\
f-Z
2 =.C5
<
)led
\�
\
] C
9
!
a
W
Y
N
N �
y Z
i 0
¢ r
O Q
2
x Z
W
aU
ai Z
O
U
LL
O
W
F
N
Y
Q
f
W
o
J
z
E
O
O
m C O
=
E
N
�
Q
o
m
=
IUu Q
m t N
v
U 2
H
0 7
Oi
�O
vi
-
N
o
10
Of
lV
O
O
� m
3
O
J
LL
O
O
J
a
S
U
O
¢
O
¢
o
fV
LQ
W
w
s n
J
¢Q
F
l7
m
E `O
O
O
IV
fV
m
O o
�
N`
L
N
<
l�
2
J
w
m
r
W
>
�
o
Q C
U i7
W
F �
Z
_ F
N
�
m � N
z
a
z
¢
m
Q
m
N
=
z
N
F
o a
� a
N m
(0
c
m
c
of
.N
m
N
C_
O
U
0
LL
O
U
O
cm
,ci
N
�l
LL
O
N
C
C.
N
N
O
U
�
O N
L
='
3
LL
c
A ❑
O
d _
,y
-0 O
c
N N
w
E
m
-e o
�
O
_
c
N
a
U
m
m-0
E
+ E
J
O
Lo
U
O II
E 0
U
o
M
C_
>
E E
Z
E
O
y
00
11
d
1
1
1
1
1
t
a
LU
N O
N Z
O Q
❑ It
¢ F
2W
a U
NO
U
LL
O
W
2
F
Y
i
R
o
_ =
LL
E
�'
O
a _
m � m
O
N
�
O
_
� E
m
U
..
p
W
J
m
W C
0 7
r
a
LL
O
fO
W
m
N
N
N
=
w
'c
m
m
U
of
0o
0
w
F
m
O
N
N
p
06 ap y^
w
N `
c
<m
N
m
J
J v
¢ =
H
c
n
m
O
O
N2 v
L_
m ? v
10
N
N
�m
m
J
❑
J
¢
W
G
O
>
O
U �
_
a W
F �
z r
e
N
m
C6
m
N
Z
w
z
a
m
<
m
2
zo
z
rl
<
-
m �
IM 0
N
❑
❑
N
n
R
}
r
N �
w Z
oa
O
}
O UJ
z U
N Z
U
LL
O
W
2
H
N
Y
Q
W
LL'
J
Q U
C Q
�
e
3
E
O
O
N
O
� E
m
U
O
N
o
Y W
u �
U �
�
N
_
C
O
U
O
LL
�
J
W
OR
N
N
N
a
C CN
C
O
m
O
U
O
O
W
o
N
w
e �^
N `�
W
t
O
N
N
CJ
j
r
o
g: N
0
V
0
V
N ` y
L
N
N
N
m
J
U
W
a
o
T
cn
0
OZ
J
U
W
m
e
O
o
0
W
t �
E
Z F
v
N
m
N
m
Nz
m
Q
m
N
z
Z
m
Q
z U
_
N
Wo a
U) a
N C
m
�
�
�
§
f
/g
$ f
cc
>—
cc
® {
§k
$
§§
cli
z
(])
<�LU
\
LL
&�
)\
\)\Cc \a
\
CO
\
�0cy cu
S
L CO cc
Cal
..•-
ooa2/ \
/LL
/
\
o
{
)
a
}
0
§
�
§ cc
Rƒ
LLI
§ƒ
�
a
§
q
cc
cc
�
cc
\
itLU
GEf;
§=ACL
—{{
§§
�
kw
3$
CC
<_
2&!
§
b�
)[
/
{\S
(}\\\o
co
\
CD
\\(]]
Ee
—)«
coc
/\\3\
/
/
/
\
§
\
(
)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
LL
LL
O
z
Y
a
W ^
aCC
W
}
O
W
c v
J
a
z
O
a
N
Y
Q
uj
W
2
Lq
U
O
Q
Q
f
O
O y
U
Q
Q
w
O
c
>
E Lm �
2
O O
Q�oa
U
0
y
N
�
_O
U
V
N
Q
c
C
1�
t0
U C
E
�
U
v
u�i
U
o
0
V
m
Q U
N
�
M
LL
O
0
z
m 0
3
N
z
z
H
a O
Q
m
U
w
0
N c
d
O d
CD
7
U
LL
0
E
O
N L N
C U
ID
C
Cn . C i
co C c
U U N m Q
D U C m c
E o
O C C ccCL ctl O
V �� II Q m
CI
N
IL
0
m
m
y
c
ui
O
z
O
Q
r
N
0
N_
U
w
a
No Text
i
1 APPENDIX C
' HYDRAULIC COMPUTATIONS
1
t
r
1
n
k
HM
Vt
James H. Stewart and .associates, ine.
Consulting Engineers
March 15, 1978
STORM DRAINAGE SWALE
COLLIIMALE SECOND FILING.'
The swale that exists at the Easterly side of Collindale, Second Filing will
receive drainage from the following areas:
Foothills Meadow Apartments - 16 Acres
Warren Shores - 23 Acres
North Shore P.U.D. - 10 Acres
Warren Lake Park - 26 Acres
Collindale, First Filing - 11 Acres
TOTAL 86 Acres
Of the above areas, North'Shore P.U.D. does have onsight detention and the
Warren Lake Park will -not increase the runoff, due to development, to a
great extent. The runoff "for a 100 year frequency storm would be as follows:
Foothills Meadows Q = 0.8 x 4.2.x 16 54. c.f.s.
Warren Shores Q = 0..6 x 4.2 x 23 =" 58 c.f.s
North Shore P.U.D. Q '0.4"x 5 x 10 =. 20 c.f.s
Warren Lake Park Q 0.4 x `5 x.26 = 52 c.f.s
Collindale. Q: = 0.6 x 5 x'11 = 33 c.f.s.,
TOTAL = 217 c.f.s.
The swale would be as shown below to carry the 100 year storm.'
i7 / /
50X /.48Gf 50) l'
A
oaG"
23DG/-.S t 6,1
/Z'
Therefore; it is determined that Buildings C, D, E, and F as shown on the
site plan would not be damaged during 4,100 year frequency storm.... "
' a� l�
Richard A. Rutherford, P.E. h L.S.
OFFICE-214::ORTIMCACEs 0 P.O:BO\429 0 FORT COLUNS•COLORADO80i22 0 TE:UMIO\EAREA 30T.IS2.9321
' Worksheet for Q100 West Drainage Easement Cross-section
Flow Element. Irregular Section
Friction Method: Manning Formula
' Solve For. Normal Depth
' Channel Slope: 0.00600 ffft
Discharge: 150,20 fP/s
Current Roughness Weighted Methr ImprovedLotters
Open Channel Weighted Roughnes: ImprovedLotters
' Closed Channel Weighted Roughne Hortons
Roughness Coefficient:
0.019
'
Water Surface Elevation:
1.53
ft
Elevation Range:
0.00 to 7.85 ft
'
Flow Area:
Wetted Perimeter.
29.48
38.76
ft'
ft
Top Width:
38.63
ft
Normal Depth:
1.53
ft
'
Critical Depth:
1.55
ft
Critical Slope:
0.00566
ftfft
Velocity:
5.09
ft/s
'
Velocity Head:
0.40
ft
Specific Energy:
1.94
ft
'
Froude Number.
1.03
Flow Type:
Supercritical
(-0+25, 2,15)
(-0+02, 0.17) 0.025
(0+02, 0.17)
(0+21, 1.55) 0.025
y '
(0+21, 4.55)
(0+25, 5.35) 0.025
SB�'4""`•Q:l¢='•;:e;,t'3F"" _Yrs"s.�Ii a. ti +^uy � , ti's-,Fiiu3 tti 6 r :-. � d �1 �'. v "r> (�..
CHon.GeometrV >..%%•„, bw+U >a.5rc<� �s:. .X> h�, ...�1°tt. .:..rkJy us.�,. .J :v� +stY...awp,':.�1'.rt�'�+u�� ...�3 T1.:-�La�:.
C
Worksheet for WOO West Drainage Easement Cross-section
-0+25 215
0+00 0.00
'
0+21 1.55
0+25 5.35
r.
IJ
' Cross Section for WOO West Drainage Easement Cross-section
'
Protect Descnptloh
Flow Element
Irregular Section
Friction Method:
Manning Formula
'
Solve For.
Normal Depth
Sechon,l)ata
Roughness Coefficient.
0.019
'
Channel Slope
0.00600 Wit
Normal Depth:
1.53 It
t
Elevation Range:
0.00 to 7.85 ft
Discharge:
150.20 Refs
C
—38.63 ft
T
1,53ft
i
V:5 N
KI
Interwest Consulting Group
DETENTION VOLUME CALCULATIONS
Rational Volumetric (FAA) Method
100-Year Event
LOCATION: MVG MORNINGSTAR - EXTENDED DETENTION BASIN A (SW)
PROJECT NO: 1173-105-00
COMPUTATIONS BY: MHM
DATE: 10/1/2013
Equations: Area trib. to pond = 1.24 acre
Developed flow = Qp = CIA C (100) = 0.49
Vol. In = Vi = T C I A = T Qo Developed C A = 0.6 acre
Vol. Out = Vo =K Qpo T Release rate, Opo = 0.5 cfs
storage = S = Vi - Vo K = 0.9 (from fig 2.1)
Rainfall intensity from City of Fort Collins IDF Curve with updated (3.67') rainfall
Storm
Duration, T
(min)
Rainfall
Intensity, I
(in/hr)
OD
(cfs)
Vol. In
Vi
(ft)
Vol. Out
Vo
(ft)
Storage
S
(ft)
Storage
S
(ac-ft)
5
9.95
6.0
1814
131
1683
0.04
10
7.77
4.7
2831
261
2570
0.06
20
5.62
3.4
4098
522
1 3576
0.08
30
4.47
2.7
4887
783
4104
0.09
40
3.74
2.3
5454
1045
4409
0.10
50
3.23
2.0
5895
1306
4589
0.11
60
2.86
1.7
6255
1567
4688
0.11
70
2.57
1.6
6561
1828
4733
0.11
80
2.34
1.4
6826
2089
4736,-
'` 0.11
90
2.15
1.3
7060
2350
4710
0.11
100
1.99
1.2
7270
2611
4659
0.11
110
1.86
1.1
7461
2873
4589
0.11
120
1.75
1.1
7636
3134
4502
0.10
130
1.65
1.0
7798
3395
4403
0.10
140
1.56
0.9
7948
3656
4292
0.10
150
1.48
0.9
8088
3917
4171
0.10
160
1.41
0.9
8220
4178
4042
0.09
170
1.35
0.8
8345
4439
3906
0.09
180
1.29
0.8
8463
4701
3762
0.09
Required Storage Volume: 4736 ft3
0.11 acre-ft
detention.xls,FAA-100yr SW POND
EXTENDED DETENTION BASIN A (SW)
Proposed Detention Pond - Stage/Storage
LOCATION: MVG - Morningstar
PROJECT NO: 1173-105-00
COMPUTATIONS BY: MHM
SUBMITTED BY: INTERWEST CONSULTING GROUP
DATE: 10/1/2013
V = 1/3 d (A + B + sgrt(A*B))
where V = volume between contours, ft3
d = depth between contours, ft
A = surface area of contour
WO WSEL•
100-yr WSEL,
SPILLWAY
TOP OF BERM
Stage
(Elev)
Surface
Area
(Ft^2)
Incremental
Storage
(Ac-ft)
Detention
Storage
(Ac-ft)
Total
Storage
(Ac-ft)
67.0
0
67.1
0
0.00
0.00
0.000
68.0
1223
0.01
0.00
0.008
68.5
2433
0.02
0.03
0.029
69.0
3642
0.03
0.06
0.064
69.70
5386
0.07
0.14
0.136
69.80
6078
0.01
0.15
0.149
70.80
0
0.05
0.20
0.195
i oiai aiorage nCq U QLU1 aya
0.195 > 0.130
detention.xls
Interwest Consulting Group
DETENTION VOLUME CALCULATIONS
Rational Volumetric (FAA) Method
100-Year Event
LOCATION: MVG MORNINGSTAR - EXTENDED DETENTION BASIN B (NW)
PROJECT -NO: 1173-105-00
COMPUTATIONS BY: MM
DATE: 10/1/2013
Equations: Area trib. to pond = 3.18 acre
Developed flow = Qo = CIA C (100) = 0.59
Vol. In = Vi = T C I A = T Qp Developed C A = 1.9 acre
Vol. Out = Vo =K QPo T Release rate, QPo = 1.2 cfs
storage = S = Vi - Vo K = 0.9 (from fig 2.1)
Rainfall intensity from City of Fort Collins IDF Curve with updated (3.67") rainfall
Storm
Duration, T
(min)
Rainfall
Intensity, I
(in/hr)
QD
(cfs)
Vol. In
Vi
(ft)
Vol. Out
Vo
(ft)
Storage
S
(ft)
Storage
S
(ac-ft)
5
9.95
18.7
5600
335
5266
0.12
10
7.77
14.6
8743
670
8073
0.19
20
5.62
10.5
12655
1339 1
11315
0.26
30
4.47
8.4
15090
2009
13081
0.30
40
3.74
7.0
16840
2679
14162
0.33
50
3.23
6.1
18202
3349
14853
0.34
60
2.86
5.4
19316
4018
15297
0.35
70
2.57
4.8
20258
4688
15570
0.36
80
2.34
4.4
21077
5358
15719
0.36
90
2.15
4.0
21800
6027
15773
0.36 "
100
1.99
3.7
22450
6697
15753
0.36
110
1.86
3.5
23039
7367
15672
0.36
120
1.75
3.3
23579
8036
15543
0.36
130
1.65
3.1
24078
8706
15372
0.35
140
1.56
2.9
24542
9376
15166
0.35
150
1.48
2.8
24976
10046
14931
0.34
160
1.41
2.6
25384
10715
14669
0.34
170
1.35
2.5
25769
11385
14384
0.33
180
1.29
2.4
26133
12055
14078
0.32
Required Storage Volume: 15773 ft3
0.36 acre-ft 7:1
detention.xls,FAA-100yr NW POND
EXTENDED DETENTION BASIN B (NW)
Proposed Detention Pond - Stage/Storage
LOCATION:
MVG - Morningstar
PROJECT NO:
1173-105-00
COMPUTATIONS BY: MHM
SUBMITTED BY:
INTERWEST CONSULTING GROUP
DATE:
10/1/2013
V = 1/3 d (A + B + sgrt(A`B))
where V = volume between contours, ft3
d = depth between contours, ft
A = surface area of contour
WO WSEL•
100-yr WSEL.
SPILLWAY
TOP OF BERM
Stage
(Elev)
Surface
Area
(Ft^2)
Incremental
Storage
(Ac-ft)
Detention
Storage
(Ac-ft)
Total
Storage
(Ac-ft)
62.80
0
63.0
180
64.0
2168
0.02
0.02
64.5
3813
0.03
0.00
0.06
65.0
5458
0.05
0.05
0.11
66.0
7535
0.15
0.20
0.26
67.0
9287
0.19
0.39
0.45
67.25
9871
0.05
0.45
0.51
67.4
10235
0.03
0.48
0.54
67.9
0
0.04
0.52
0.58
I Otdl Jluldyu i icy .a vw.uyv
0.540 > 0.377
detention.xls
I
1
1
1
1
1
1
1
1
fl
1
1
1
0
a
N
S
c
J
o
0oto3l)
�o
a
Iz-
r
N
C
°
N
3 a
a J
°w
d J
UJ
oU)
c
Zt�
E m
o
a
E _
° o
o
N
O
O
p� U
3
°� C
y I
N
N
N
N
��vv
L
aUi�:
u�o Ian
_
"yarn
Cl) a
=
v
c L 3
c 3_
v c;o
r n n
>�Z o
o
-
.0
II II
y
N
d i p
° °L
N N E
NQ
II II II,
> NaJ1
II II II
>
II II 11.
D
II
m w
3om
^pd
�
'>p
C o N
as E
3
o
u n
ca
O F., LI
n
U2J
19
�nm
El)
O
O
J
O L
d
0 N
U OcAF
Ica
°
U
c
d y N
m S d
Em
-
cw
�y�yq
w
O
rom
fA
2/6/2014
' LOCATION: MVG MORNINGSTAR
ITEM: RIPRAP CALCULATIONS FOR OVERFLOW SPILLWAYS
COMPUTATIONS BY: MM
' SUBMITTED BY: INTERWEST CONSULTING GROUP
Riprap requirements for a stable channel lining are based on the equation from
Storm Drainage Design Criteria, City of Fort Collins, CO, Vols. 1,23 & 3, December 2011
V S01
= 5.8
'
(d,). (SS-1).
where:
V = mean channel velocity (tt/s)
S = longitudinal channel slope (f Jft)
'
S, = specific gravity of rock (minimum S. = 2.50)
d5 = rock size in feet for which 50 percent of the riprap by weight is smaller
Determine if riprap is required
using Table 8-2
'
Longitudinal Specific
Class of
d,
Min. Riprap
Velocity Slope Gravity VS"
Froude
Is
Rtprap
Table MD-10
Thickness
LOCATION
(fUs) (tuft) of Rock (S, - 1)0'�
Number
F < 0.8 7
Table MD-10
(in)
(in)
SW DETENTION BASIN
2.8 0.005 2.5 0.87
0.70
TRUE
VL
6.00
10.50
'
NW DETENTION BASIN
2.5 0.02 2.5 0.98
0.62
TRUE
VL
6.00
10.50
I
C
RIPRAP2.xls
)
\
�
2
as
E
2�^
�«f
. ©_
§)/»
R
\
2>
k
/000
2q��
c
> CO
k
E$ \
k �~
§2�t3$]\
k =
0 (D
%k�
.0
ao)
QT §
k L 2
&
e �
S\\¢)§&&
tm
0
A�;LU--ja
a
-555a�\/
\_,.,,
��
>
Via«
»2
»k
\
\k
\
/k
§
k
§
)
�\
\
«�
k
CU
k\
�c
§
[)
cc
Zr
.k
�q
§
§
wo
\
.
c
}
E
&
0
2
f
to
¥j
>\
0
J = a
^
cm
2=\/§
±
t�a±&2
\k�\
�a,(D
0
\o
��%t$O
QatE3:
.sS.
oq
\===3
KLo
�c
R/oc�>
„
.,,
\\
§2
\k
\
)
e
\ �
\�
3 K
e
\k
\F8
a
\\E\
2�
�
k�
r
.�®
IL
6 t
�
a
§
k
wLL
qN
A�q
� 0
�3
j
<
E
C
1
i
1
1
1
1
1
1
1
1
APPENDIX D
WATER QUALITY
f7
No Text
Design Procedure Form: Extended Detention Basin (EDB) - Sedimentation Facility
Sheet 1 of 3
Designer: MM
Company: Interwest Consulting Group
Date: December 6, 2013
Project: MVG - Morningstar Facility
Location: DETENTION BASIN A (SW)
1. Basin Storage Volume
1, =
38.00
A) Tributary Area's Imperviousness Ratio (i = la/ 100)
i =
0.38
B) Contributing Watershed Area (Area)
Area =
1.240
acres
C) Water Quality Capture Volume (WQCV)
WQCV =
0.17
watershed inches
(WQCV =1.0 ' (0.91 " 13 - 1.19 12 + 0.78. 1))
D) Design Volume: Vol = (WQCV / 12)' Area' 1.2
Vol =
0.0216
acre-feet
2. Outlet Works
A) Outlet Type (Check One) x Orifice Plate
Perforated Riser Pipe
Other:
B) Depth at Outlet Above Lowest Perforation (H)
H =
1.60
feet
C) Recommended Maximum Outlet Area per Row, (k)
Ae =
0.1
square inches
D) Perforation Dimensions:
i) Circular Perforation Diameter or
D =
0.500
inches
ii) Width of 2" High Rectangular Perforations
W =
. inches
E) Number of Columns (nc, See Table 6a-1 For Maximum)
nc =
1
number
F) Actual Design Outlet Area per Row (k)
Aa =
0.2
square inches
G) Number of Rows (nr)
nr =
5
number
H) Total Outlet Area (kO
A., =.
1.0
square inches
3. Trash Rack
A) Needed Open Area: A, = 0.5' (Figure 7 Value)
A, = 35 square inches
B) Type of Outlet Opening (Check One)
x < 2" Diameter Round
2" High Rectanaular
Other:
C) For 2", or Smaller, Round Ooenina (Ref.: Figure 6a):
i) Width of Trash Rack and Concrete Opening (W,,.)
from Table 6a-1
WCO. _' 3 inches
ii) Height of Trash Rack Screen (H�)
Hm = 54 inches
UD-BMP_v2.06.xls, EDB - SW POND
12/6/2013, 10:28 AM
Design Procedure Form: Extended Detention Basin (EDB) - Sedimentation Facility
Sheet 2 of 3
Designer:
MM
Company:
Interwest Consulting Group
Date:
December 6, 2013
Project:
MVG - Morningstar Facility
Location:
DETENTION BASIN A (SW)
iii) Type of Screen (Based on Depth H), Describe if "Other" S.S. #93 VEE Wire (US Filter)
Other:
iv) Screen Opening Slot Dimension, Describe if "Other" I 0.139" (US Filter)
Other:
v) Spacing of Support Rod (O.C.)
Type and Size of Support Rod (Ref.: Table 6a-2)
vi) Type and Size of Holding Frame (Ref.: Table 6a-2)
inches
D) For 2" High Rectangular Opening (Refer to Figure 61b):
1) Width of Rectangular Opening (W)
W =
inches
ii) Width of Perforated Plate Opening (W.. = W + 12")
Ww� =
inches
iii) Width of Trashrack Opening (W,;v) from Table 6b-1
W�Nm _
.. inches
iv) Height of Trash Rack Screen (HT
HTR =
inches
v) Type of Screen (based on depth H) (Describe if "Other")
KlempT" KPP Series Aluminum
Other:
A Cross -bar Spacing (Based on Table 6b-1, KlempT/A KPP I inches
Grating). Describe if "Other" Other:
vii) Minimum Bearing Bar Size (Klemp' Series, Table 6b-2)
4. Detention Basin length to width ratio I (IJW)
5 Pre -sedimentation Forebay Basin - Enter design values
A) Volume (3% to 5% of Design Volume from 1D). acre-feet
(3%-5%of Design Volume,(0.0006 - 0.0011 acre-feet.) C "
B) Surface Area acres
C) Connector Pipe Diameter inches
(Size to drain this volume in 5-minutes under inlet control)
D) Paved/Hard Bottom and Sides yes/no
UD-BMP v2.06.xis, EDB - SW POND 12/6/2013, 10:2B AM
Design Procedure Form: Extended Detention Basin (EDB) - Sedimentation Facility
Sheet 3 of 3
Designer: MM
Company: Interwest Consulting Group
Date: December 6, 2013
Project: MVG - Morningstar Facility
Location: DETENTION BASIN A (SW)
6. Two -Stage Design - See Figure EDB-1
A) Top Stage (Depth Dwo = 2' Minimum)
Dwo =
feet
- - Top Stage Storage: no less than 99.5% of Design Volume (0.0215,acre-feet.)_
Storage=
acre-feet
B) Bottom Stage Depth (Des = 0.33' Minimum Below Trickle Channel Invert)
Des =
feet
Bottom Stage Storage: no less than 0.50% of Design Volume (0.0001 acre-feet.)
Storage=
acre-feet
Storage = A " Depth Above W S To Bottom Of Top Stage
Surf. Area=
acres
C) Micro Pool (Minimum Depth = the Larger of
Depth=
feet
0.50 " Top Stage Depth or 2.5 Feet)j
D) Total Volume: Volga = Storage from 5A + 6A + 6B
Vol'o' =
acre-feet
-. '-- (Must be > Design Volume in 1 D, or 0.0216 acre-feet.)
7. Basin Side Slopes (Z, horizontal distance per unit vertical)
Z =
(horizontaUvertical)
Minimum Z = 4, Flatter Preferred
8. Dam Embankment Side Slopes (Z, horizontal distance)
Z =
(horizontaUvertical)
per unit vertical) Minimum Z = 3, Flatter Preferred
9. Vegetation (Check the method or describe "Other")
Native Grass
Irrigated Turf Grass
Other:
Notes: .
' UD-BMP_v2.06.xls, EDB - SW POND 12/6/2013, 10:28 AM
Design Procedure Form: Extended Detention Basin (EDB) - Sedimentation Facility
Sheet 1 of 3
Designer: MM
Company: Interwest Consulting Group
Date: December 6, 2013
Project: MVG - Morningstar Facility
Location: DETENTION BASIN B (NW)
1. Basin Storage Volume
la =
47.00
A) Tributary Area's Imperviousness Ratio (i = la / 100)
i =
0.47
B) Contributing Watershed Area (Area)
Area =
3.180
acres
C) Water Quality Capture Volume (WQCV)
WQCV =.
0.20
watershed inches
(WQCV =1.0'(0.91'13-1.19'I2+0.78.0)
D) Design Volume: Vol = (WQCV / 12) ' Area' 1.2
Vol =
0.0630
acre-feet
2. Outlet Works
A) Outlet Type (Check One) x Orifice Plate
Perforated Riser Pipe
Other:
B) Depth at Outlet Above Lowest Perforation (H)
H =
1.95
feet
C) Recommended Maximum Outlet Area per Row, (Ao)
Ao =
0.2
square inches
D) Perforation Dimensions:
i) Circular Perforation Diameter or
D =
0.500
inches
ii) Width of 2" High Rectangular Perforations
W =
inches
E) Number of Columns (nc, See Table 6a-1 For Maximum)
nc ='.
1
number
F) Actual Design Outlet Area per Row (Ao)
Ao =
0.2
square inches
G) Number of Rows (nr)
nr =
6
number
H) Total Outlet Area (A.0
Ao, =
1.2
square inches
3. Trash Rack
A) Needed Open Area: A, = 0.5' (Figure 7 Value) ' Ao,
A, = 42 square inches
B) Type of Outlet Opening (Check One)
x < 2" Diameter Round
2" High Rectangular
Other:
C) For 2", or Smaller, Round Opening (Ref.: Figure 6a):
i) Width of Trash Rack and Concrete Opening (W..)
from Table 6a-1
,...
W.m = 3 inches
ii) Height of Trash Rack Screen (HTR)
HTR = 54 inches
UD-BMP_v2.06.xls, EDB - NW POND
12/6/2013, 10:29 AM
1 Design Procedure Form: Extended Detention Basin (EDB) - Sedimentation Facility 11
Sheet 2 of 3
Designer:
MM
Company:
Interwest Consulting Groul
Date:
December 6, 2013
Project:
MVG - Morningstar Facility
Location:
DETENTION BASIN B (NW)
iii) Type of Screen (Based on Depth H), Describe if "Other" S.S. #93 VEE Wire (US Filter)
Other:
iv) Screen Opening Slot Dimension, Describe if "Other"
0.139" US Filter
Other:
v) Spacing of Support Rod (O.C.)
Type and Size of Support Rod (Ref.: Table 6a-2)
vi) Type and Size of Holding Frame (Ref.: Table 6a-2)
inches
D) For 2" High Rectangular Opening (Refer to Figure 61b):
1) Width of Rectangular Opening (W)
W =
inches
ii) Width of Perforated Plate Opening (W.. = W + 12")
W.z =
inches
iii) Width of Trashrack Opening (W,o„ .) from Table 6b-1
W,o,, v. =
inches
iv) Height of Trash Rack Screen (Hm)
Hm =
inches
v) Type of Screen (based on depth H) (Describe if "Other")
Klempn' KPP Series Aluminum
Other:
vi) Cross -bar Spacing (Based on Table 6b-1, Klempn KPP I inches
Grating). Describe if "Other" Other:
vii) Minimum Bearing Bar Size (KlempT"' Series, Table 6b-2)
Based on depth of WOCV surcharge)
4. Detention Basin length to width ratio (UW)
5 Pre -sedimentation Forebay Basin - Enter design values
A) Volume (3%, to 5% of Design Volume from 1 D) acre-feet
(3% - 5% of Design Volume (0.0019 -. 0.0032 acre-feet)...:_
B) Surface Area acres
C) Connector Pipe Diameter inches
(Size to drain this volume in 5-minutes under inlet control)
D) Paved/Hard Bottom and Sides yes/no
UD-BMP_v2.06.xls, EDB - NW POND
12/6/2013, 10:29 AM
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Design Procedure Form: Extended Detention Basin (EDB) - Sedimentation Facility II
Sheet 3 of 3
Designer: MM
Company: Interwest Consulting Group
Date: December 6, 2013
Project: MVG - Morningstar Facility
Location: DETENTION BASIN B (NW)
6. Two -Stage Design - See Figure EDB-1
A) Top Stage (Depth Dwo = 2' Minimum)
Dwo =
feet
;Top Stage Storage: no less than,99.5%of Design Volume '.(0.0627 acre' -feet.) -
Storage=
acre-feet
B) Bottom Stage Depth (Dos = 0.33' Minimum Below Trickle Channel Invert)
DBS =
feet
Bottom Stage Storage: 'no less than 0.50% 03 of Design Volume (0.00acre-feet.)
Storage=
acre-feet
Storage = A' Depth Above WS To Bottom Of Top Stage
Surf. Area=,
acres
C) Micro Pool (Minimum Depth = the Larger of
Depth=
feet
'.0.50' Top Stage Depth or 2.5 Feet) -.
-
D) Total Volume: Vol,,, = Storage from 5A + 6A + 6B
Volvo, =
acre-feet
(Must be > Design Volume in 1 D, or 0.063 acre-feet.)
7. Basin Side Slopes (Z, horizontal distance per unit vertical)
Z =
(horizontal/vertical)
Minimum Z = 4, Flatter Preferred
B. Dam Embankment Side Slopes (Z, horizontal distance)
Z =
(horizontal/vertical)
per unit vertical) Minimum Z = 3, Flatter Preferred
9. Vegetation (Check the method or describe "Other")
Native Grass
Irrigated Turf Grass
Other:
UD-BMP_v2.06.xls, EDB - NW POND
12/6/2013, 10:29 AM
T_2 Grass Swale
RESIDUAL CAPACITY FOR
LARGER FLOODS
2—YR
4" (MIN) SANDY LOAM I v 1' MIN
12" MIN
BOTTOM WIDTH M
RESIDUAL CAPACTY FOR �
`�Y' � tARCER FLOODS ��
2—YR WSE ,� a �74 MIN.
6' MIN - ..
4' MIN. SANDY LOAM
1 1' MIN.
D (2-YR) 1.0 FPS 12' N
TRIANGULAR SWALE SECTION
NTS
CONCRETE COLLAR
i i r ENERGY
PROVIDE DOUBLE CLEANOUTS
WITH WATER TIGHT CAPS 0150'
O.C. USE 90' SWEEP OR (2)
45 BENDS (OFFSET FROM SWALE
CENTERLINE TO AVOID IMPEDING
FLOW WHEN USING A TRIANGULAR
SECTION
GRADE CONTROL
STRUCTURE
4 MIN.
GRADE CONTROL STRUCTURE
BEYOND
GRADE CONTROL STRUCTURE
BEYOND
O UNDERDRAIN AND SANDY LOAM RECOMMENDED FOR
LONGITUDINAL SLOPES < 2.0%. 4" SLOTTED PIPE
MEETING TABLE GS-3 WITH CDOT CLASS C FILTER
MATERIAL ALL AROUND OR PERFORATED HDPE
PIPE WITH AASHTO 167 ALL AROUND CONTAINED
WITHIN GEOTEXTILE FABRIC. ASTM D4751—AOS US
STD. SIEVE f50 TO #70. ASTM D4533 MIN.
TRAPEZOIDAL TEAR STRENGTH 100 X 60 LBS,
MINIMUM COE SPECIFIED OPEN AREA OF 49.
EXTEND GRADE CONTROL
STRUCTURES INTO THE
BANK A MIN. 0.5'
ABOVE THE 2—YR WSE
ENSURE ACCESS TO OUTLET
BY CLEAN OUT OR OTHER
ACCESSIBLE STRUCTURE
SWALE PROFILE
NTS
Figure GS-1. Grass Swale Profile and Sections
Design Example
The UD-BMP workbook, designed as a tool for both designer and reviewing agency is available at
www.udfcd.ore. This section provides a completed design form from this workbook as an example.
GS-6 Urban Drainage and Flood Control District November 2010
Urban Storm Drainage Criteria Manual Volume 3
Extended Detention Basin (
T-5
FLOW LENGTH Z2W ACCESSIBLE OUTLET
���� WITH TRASH RACK
01 4:1 SIDFSLOPES WITH NO AREAS
GREATER THAN 3:1. FOR AESTHETIC
•4,
VARY SLOPES AND DESIGN
SHE
OIL RIPRAP (WHEN
. i''
DE MILDER THAN THE OTHER.
ON SIDE
ONE
DOWNSTREAM GRADE
D
IS LOWER THAN TOP
MICROPOOL t=
OF BERM)
'
® CONCRETE
/
ROCWITH
O
GROUTED ROCK FLOOR. PROVIDE
GROUTED
ENERGY OSSSIPATION FOR
CONCENTRAlEO FLOW.
\O
SP14K'AY
tl
Q N THE BOTTOM OF THE BASIN
�`f (,
/
PRO. IDE A 3% MIN. SLOPE TO
THE
IC LE CHANNEL ORMICR
•
///
/
F?
0
O
4
�O
�--TRICKLE CHANNEL. FOR CONCRETE. SLOPE BETWEEN 0.4.AND I=
3:1 MAX. (BERM)
OR VERTICAL CONC. PAN WALL L
NTS
INITIAL SURCHARGE EMBANKMENT WITH
SURFACE PROVIDE DEPTH! 4' MIN., SPILLWAY
NERGY
INFLOW � IF� EI CONIC. D BERM OR DEPTH
DISSIPATION 2.3' MIN,
INFLOW ARMORED BERM OR VERTICALWALL
CONCRETE OR
GROUTED BOULDER/
FOREBAY J
8- MIN. PIPE
WITH BERM. USE
NOTCH FOR WALL
'SOFT BOTTOM WHERE BASE FLOWS
OR GROUNDWATER IS ANTICIPATED
'INCREASE WHERE BASE
FLOWS ARE ANTICIPATED
�— INVERT OF — E
TRICKLE
CHANNEL
CONCRETE TRICKLE
CHANNEL RUNDOWN
CONCRETE OR SOFT
BOTTOM' MICROPOOL
OUTLET WORK (SEE
ADDITIONAL DETAILS
PR FI IN FACT SHEET 7-12)
NTS SEEPAGE CUTOFF
COLLAR OF
NECESSARY)
Figure EDB-3. Extended Detention Basin (EDB) Plan and Profile
Additional Details are provided in BW Fact Sheet T-12. This iikhides outlet structure
details including orifice plates and trash racks.
December 2010 Urban Drainage and Flood Control District EDB-11
Urban Storm Drainage Criteria Manual Volume 3
T-10
Permeable Pavement
PERMEABLE PAVEMENT AND�
LEVELING COURSE (IF APPLICABLE)
60 MIN. DEPTH DEPENDANT
RESERVOIR
r r r• e.• r r r s r r r r s r r r r Y r r• 0� r r r'r • r• �'
r�rr:rr'...... rr.rs------ rrfrrtrr�i�rgr
L• ♦ rti.• • • •'Y ♦ • r°"t ti-r � r * � r r r is r �i y� � r fir.
GEOMEM RiANE LINER ¢ r
CONNECTION TO m e FILTER MATERIAL
CONCRETE.
MEETING TABLE PPS-1
(SEE DETAIL PPS-4)' 12* SEPARATOR FABRIC
UNDERDRAIN MEETING
TABLE PPS-2 30 MIL (MIN.) SEPARATOR FABRIC (ONLY
r ENSURE INSTALLATION IS CONSISTENT GEOME'MBRANE WHEN SUBGRADE CONTAINS
WITH MANUFACTURER RECOMMENDATIONS LINER PER TABLE PP$-4 ANGULAR ROCK OR OTHER
T MAPUNM
NO -INFILTRATION SECTION TH EMI E LINER�
PERMEABLE PAVEMENT AND
6" MIN_ LEVELING COURSE (IF APPLICABLE)
DEPTH DEPENDANT ON TYPE
PERIMETER BARRIER 6' MIN. RESERVOIR
— (IF APPLICABLE) (AASHTO #57 OR #67) \ I
NI -FILTER MATERIAL MEETING TABLE
PPS-1 OR SEPARATOR FABRIC
IF NEEDED FOR MATERIAL COMPAMBILTTY.
TO BE DETERMINED BY A GEOTECHNICAL
ENGINEER
FULL INFILTRATION SECTION
Figure PPS-1- Permeable Pavement Sections
PPS-6 Urban Drainage and Flood Control District August 2013
Urban Storm Drainage Criteria Manual Volume 3
T-10 Permeable Pavement Systems
H
a" SOLID PIPE STORM MANHOLE Y .
A OR VAULT {tire.)
M-ZTO OUTLET
n�
■
i
i
�
•
■
G
PLAN VIEW
. NTS
PLACE LARGER .ROCK
(AASHTO /3) TO
TO OVERFLOW TO
B CONFUJE RESERVOIR
MATERIAL
Nff
.'� \y
RISER SUPORTED
WITH METAL STRAPS
ANCHORED TO WALL
UNDERDRAIN FLOW--f
FROM CELL
TO LOWER
CELL
ICRETE BOTTOM
EO SUBGRADE
i SLOTTED PVC MEETING
TABLE PPS-2
CONCRETE EDGE
{WHERE APPLICABLE)
PROVIDE OVERFLOW FROM RESERVOIR
((TOP i' OF RESERVOIR LAYER) TO,
AVOID BACNWASHING PAVEMENT
TOP OF RISER ELEVATION
SET AT WOCV AND NO
HIGHER THAN I* BELOW
THE TOP OF THE
RESERVOIR LAYER
ro 6RAIN_THE
OF THE WOCV
EACH CELL IN
y�y+yy,•»yy>.vr OR MORE
PT47i*769"^
Figure PPS-7. Underdrain System Layout and Outlet Details
PPS-18 Urban Drainage and Flood Control District August 2013
Urban Stonn Drainage Criteria Manual Volume 3
Permeable Pavement Systems T-10
PERMEABLE
PAVEMENT
BASE COURSE
FILTER LAYER
SUBGRADE
CAST IRON VALVE BOX
WITH LOCKING LID
REMOVABLE PVC THREADED
PLUG & COUPLER
3' MIN. THICK
CONCRETE COLLAR
CONCRETE EDGE
RESTRAINT (IF
APPLICABLE)
SECTION
Figure PPS-$. Observation Well
4"0 SLOTTED
PVC PIPE MEETING
TABLE PPS-2
(TERMINATE PIPE AT
THE BOTTOM OF THE
FILTER LAYER WITH A
NO INFILTRATION
SECTION)
August 2013 Urban Drainage and Flood Control District , PPS-19
Urban Storm Drainage Criteria Manual Volume 3