Loading...
HomeMy WebLinkAboutDrainage Reports - 12/16/20131 t 1 t ' This Drainage Report is consciously provided as a PDF. Please consider the environment before printing this document in its entirety. When a hard copy is absolutely necessary, we recommend double -sided printing. City of Ft. CoNnve ber 2��? Plens Approved By. Date z'l b 13 FINAL DRAINAGE REPORT PATEROS CREEK Fort Collins, Colorado Prepared for: Bucking Horse, LLC 3702 Manhattan Ave., Suite 201 Fort Collins, CO 80526 Prepared by: ■� NORTHERN ENGINEERING 200 South College Avenue, Suite 10 Fort Collins, Colorado 80524 Phi 970.221.4158 Fax: 970.221,4159 www.northemenginnuing.com Project Number: 687-001 Northernlingineering.cons // 970.221.4158 i H 1 1 i 1 00 e PHONE: 970.221.4158 2Coll NORTHERN 00 S. College Ave. Suite 10 WEBSITE: ENGINEERING Fort Collins, CO 80524 FAX: 970.221.4159 ww .northernengineering.com November 26, 2013 City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, Colorado 80521 RE: Final Drainage Report for PATEROS CREEK 1 Dear Staff: Northern Engineering is pleased to submit this Final Drainage Report for your review. This report 1 accompanies the Project Development Plan submittal for the proposed Pateros Creek development. 1 1 1 1 1 1 , 1 1 1 1 This report has been prepared in accordance to Fort Collins Stormwater Criteria Manual (FCSCM), and serves to document the stormwater impacts associated with the proposed project. We understand that review by the City is to assure general compliance with standardized criteria contained in the FCSCM. If you should have any questions as you review this report, please feel free to contact us. ZRING SERVICES, INC. NORTHERN ENGINEERING CIRTH TABLE OF CONTENTS I. GENERAL LOCATION AND DESCRIPTION................................................................... 1 A. Location.............................................................................................................................................1 B. Description of Property.....................................................................................................................2 C. Floodplain..........................................................................................................................................3 ll. DRAINAGE BASINS AND SUB-BASINS....................................................................... 7 A. Major Basin Description....................................................................................................................7 III. DRAINAGE DESIGN CRITERIA................................................................................... 7 A. Regulations........................................................................................................................................7 B. Four Step Process..............................................................................................................................7 C. Development Criteria Reference and Constraints............................................................................8 D. Hydrological Criteria.........................................................................................................................9 E. Hydraulic Criteria..............................................................................................................................9 F. Floodplain Regulations Compliance..................................................................................................9 G. Modifications of Criteria.................................................................................................................10 IV. DRAINAGE FACILITY DESIGN.................................................................................. 10 A. General Concept.............................................................................................................................10 B. Specific Details................................................................................................................................11 V. CONCLUSIONS......................................................................................................12 A. Compliance with Standards............................................................................................................12 B. Drainage Concept............................................................................................................................12 References....................................................................................................................... 13 APPENDICES: APPENDIX A — Hydrologic Computations APPENDIX B — Hydraulic Computations B.1 — Storm Sewers B.2 — Inlets B.3 — Swales APPENDIX C — Detention and Water Quality Design Computations APPENDIX D — Erosion Control Report APPENDIX E — Supplemental Information: FEMA FIRMette, LOMR-F Final Drainage Report NORTHERN ENGINEERING LIST OF TABLES AND FIGURES: Figure1 — Aerial Photograph................................................................................................ 2 Figure 2— Proposed Site Plan................................................................................................3 Figure 3 — Existing Floodplains............................................................................................. 4 Figure 4 — Foundation Detail................................................................................................ 5 Table1 — LOMR-F Summary ................................................................................................ 6 Table 2 — Water Quality Pond Summary ............................................................................... 11 MAP POCKET: Historic Drainage Exhibit Offsite Basin Exhibit Proposed Drainage Exhibit Floodplain Exhibit Final Drainage Report (NORTHERN ENGINEERING I. GENERAL LOCATION AND DESCRIPTION A. Location 1. Vicinity Map LOCATION Pateros Creek 2. The project site is located in the southwest quarter of Section 2, Township 7 North, Range 69 West of the 6" Principal Meridian, City of Fort Collins, County of Larimer, State of Colorado. 3. The project site is located on the south side of Wood Street, and just north City of Fort Collins Utilities Building. The Cache La Poudre River runs just to the north of the project site. 4. The project site lies within Old Town Master Basin (City of Fort Collins, July 2003). The site will outfall to the Cache La Poudre River. Due to the project site proximity to the river, no detention is required for onsite runoff. 5. Residential development exists to the south and west of the site. 6. Offsite flows from the south are routed through the site via an existing CMP pipe at the southeast corner of the site. This pipe drains runoff and excess water from the existing pond located along the southern boundary of the site, as seen in Figure 1. The pipe passes flows into the existing onsite pond. The existing onsite pond drains via an existing 24-inch pipe into a swale, which conveys flows northeast to the Cache La Poudre River. Please see the Offsite Basin Exhibit provided in the back map pocket of this report. Final Drainage Report 1 I 1 1 1 N9RTHERN ENGINEERING B. Description of Property 1. The development area is roughly 9.3 net acres. Figure 1 — Aerial Photograph 2. The subject property now consists of vacant ground. In 2012 the site was cleared of a mobile home park that had existed for several decades on the property. The ground cover generally consists of native seeding. Existing ground slopes are mild (i.e., 1 - 3±%) through the interior of the property. General topography slopes from southwest to the northeast towards the Cache La Poudre River. 3. According to the United States Department of Agriculture (USDA) Natural Resources Conservation Service (NRCS) Soil Survey website: http://websoilsurvey.nrcs.usda.gov/app/WebSoilSurvey.aspx, the site consists of Paoli fine sandy loam and Table Mountain Loam, which fall into Hydrologic Soil Group B; and Table Mountain Loam. More site -specific exploration found varying materials including sandy clay with occasional sand layers and sandy gravel. See the Geotechnical Engineering Report by Earth Engineering Consultants, Inc. for additional information. 4. The proposed project will create a residential development. Associated roadways, water and sewer lines will be constructed with the development. A water quality forebay will be constructed near the southeast corner of the site. The existing wet pond at the southeast corner of the site will be utilized for stacked detention. [1 Final Drainage Report W INORTHERN ENGINEERING 1 1 1 1 1 Aw 1141 ,. Figure 2— Proposed Site Plan 5. There are no irrigation ditches or related facilities in the vicinity of the project site. 6. The proposed land use is residential. C. Floodplain 1. A portion of the subject property is encroached by the FEMA 100-year Floodplain (Cache La Poudre River). Please see the Floodplain Exhibit provided in the back map pocket of this report. Final Drainage Report 3 I 1 1 1 1 1 L 1 1 1 1 1 1 1 1 1 1 1 W I NOMERN ENGINEERING Pateros Creek Figure 3 — Existing Floodplains 2. No offsite improvements are proposed with the project. 3. FEMA FIRM Panel Number 977 for Larimer County, dated June 17, 2008 is referenced in this study. A FIRMette of the area is provided in the appendix. A LOMR-F was completed March 22, 2012 (FEMA case no. 12-08-0323A). A copy of this LOMR-F is provided in the Appendix. All lots removed from the FEMA 100-year flood zone are noted on the Floodplain Exhibit (please see back map pocket). Regulatory Flood Protection Elevations and Base Flood Elevations are shown on this exhibit. Additionally, requirements for the elevation of the lowest floor, HVAC and electrical, the type of foundation for the LOMR-F lots, floodplain permit and CO requirements, and no -rise certification requirements in the floodway are noted on the Floodplain Exhibit. A foundation detail and LOMR-F summary table are provided below. ' Final Drainage Report 4 W INORTHERN ENGINEERING LOWEST FLOOR ELEVATION = C REGULATORY FLOOD _ PROTECTION ELEVATION BASE FLOOD ELEVATION N _ (BFE) = A DETAIL NTS Figure 4 - Foundation Detail Pateros Creek MINIMUM HVAC EQUIPMENT ELEVATION = B a� BASE FLOOD ELEVATION BFE A Final Drainage Report 5 " 2 )§| ro .|� §; E|| --..,.. .�; §E `:<,,,_-@ ;■®�::,); §! ; , ( �( §�(� §� |0 \S Pateros «+ Final _« Report | NORTHERN ' ENGINEERING ' 4. Base (100-year) flood elevations range from roughly 4973 at the east end of the site to 4977 at the west end of the site. These elevations are referenced to the City of Fort Collins NGVD 29. 5. The proposed structures are located outside of the 100-year floodplain; however some of the proposed residential structures lie within the 500-year floodplain. Two lots are shown within the West Vine Floodway (Lots 1 and 2). It has been noted on the ' Floodplain Exhibit (please see back map pocket) that these lots cannot be developed until the West Vine Floodway is removed. Lots 9 - 14 and Lots 31 — 33 were ' removed from the floodplain via a LOMR-F. 6. The Cache La Poudre half -foot floodway is located outside of the development area. No fill is proposed within the floodway 7. Stabilization measures are currently being proposed along the bend in the Cache La Poudre River northwest of the project site. All stabilization design work is being conducted by the City of Fort Collins. ' 8. It is noted that the vertical datum utilized for site survey work is the City of Fort Collins Benchmark #10-00 (Elevation=4988.43, Ft. Collins Unadjusted NGVD 29). ' II. DRAINAGE BASINS AND SUB -BASINS ' A. Major Basin Description 1. The project The project site lies within Old Town Master Basin (City of Fort Collins, July 2003). The site will outfall to the Cache La Poudre River. Due to the project ' site proximity to the river, no detention is required for onsite runoff. B. Sub -Basin Description ' 2. The subject property historically drains overland towards the Cache La Poudre River, which runs north of the site. A more detailed description of the project drainage patterns follows in Section IV.A.4., below. ' 3. Flows from the pond just to the south of the site historically drain through the project site. A 12-inch diameter pipe conveys flow from the offsite pond into the existing wet pond at the southeast corner of the site. A 24-inch pipe drains the existing wet pond ' into an offsite swale that runs northeast into the Cache La Poudre River. No modifications are proposed to the 24-inch outlet pipe. Therefore, flows will continue to pass through the existing onsite wet pond with the proposed development. ' III. DRAINAGE DESIGN CRITERIA ' A. Regulations There are no optional provisions outside of the FCSCM proposed with the proposed ' project. B. Four Step Process ' The overall stormwater management strategy employed with the proposed project utilizes the "Four Step Process" to minimize adverse impacts of urbanization on receiving waters. ' Final Drainage Report 7 .� NORTHERN ENGINEERING Pateros Creek The following is a description of how the proposed development has incorporated each step. Step 1 — Employ Runoff Reduction Practices Several techniques have been utilized with the proposed development to facilitate the reduction of runoff peaks, volumes, and pollutant loads as the site is developed from the current use by implementing multiple Low Impact Development (LID) strategies including: ' NO Conserving existing amenities in the site including the existing vegetated areas. NI] Providing vegetated open areas throughout the site to reduce the overall impervious area and to minimize directly connected impervious areas (MDCIA). ' Na Routing flows, to the extent feasible, through vegetated swales to increase time of concentration, promote infiltration and provide initial water quality. ' Step 2 — Implement BMPs That Provide a Water Quality Capture Volume (WQCV) with Slow Release The efforts taken in Step 1 will facilitate the reduction of runoff; however, urban ' development of this intensity will still generate stormwater runoff that will require additional BMPs and water quality. The majority of stormwater runoff from the site will ultimately be routed to the southeast corner of the site, where it will be intercepted and treated in the main water quality forebay prior to entering the existing wet pond and then ' exiting the site. Step 3 — Stabilize Drainageways There are no major drainageways within the subject property. While this step may not ' seem applicable to proposed development, the project indirectly helps achieve stabilized drainageways nonetheless. By providing water quality where none previously existed, sediment with erosion potential is removed from the downstream drainageway systems and Cache La Poudre River. Furthermore, this project will pay one-time stormwater development fees, as well as ongoing monthly stormwater utility fees, both of which help achieve City-wide drainageway stability. Step 4 — Implement Site Specific and Other Source Control BMPs. The proposed project will improve upon site specific source controls compared to historic conditions: NO Trash, waste products, etc. that were previously left exposed with the historic trailer park will no longer be allowed to exposure to runoff and transport to the adjacent Cache La Poudre River. The proposed development will eliminate these sources of potential pollution. C. Development Criteria Reference and Constraints The subject property is surrounded by currently developed properties. Thus, several constraints have been identified during the course of this analysis that will impact the proposed drainage system including: NO Existing elevations along the west and south property lines will be maintained. NO As previously mentioned, overall drainage patterns of the existing site will be maintained. Na Elevations of existing downstream facilities that the subject property will release to will be maintained. Final Drainage Report ■� I NORTHERN ENGINEERING D. Hydrological Criteria Pateros Creek 1. The City of Fort Collins Rainfall Intensity -Duration -Frequency Curves, as depicted in Figure RA-16 of the FCSCM, serve as the source for all hydrologic computations associated with the proposed development. Tabulated data contained in Table RA-7 has been utilized for Rational Method runoff calculations. 2. The Rational Method has been employed to compute stormwater runoff utilizing coefficients contained in Tables RO-11 and RO-12 of the FCSCM. 3. Three separate design storms have been utilized to address distinct drainage scenarios. A fourth design storm has also been computed for comparison purposes. The first design storm considered is the 8Oth percentile rain event, which has been employed to design the project's water quality features. The second event analyzed is the "Minor," or "Initial" Storm, which has a 2-year recurrence interval. The third event considered is the "Major Storm," which has a 100-year recurrence interval. The fourth storm computed, for comparison purposes only, is the 10-year event. 4. No other assumptions or calculation methods have been used with this development that are not referenced by current City of Fort Collins criteria. E. Hydraulic Criteria 1. As previously noted, the subject property maintains historic drainage patterns. 2. All drainage facilities proposed with the project are designed in accordance with criteria outlined in the FCSCM and/or the Urban Drainage and Flood Control District (UDFCD) Urban Storm Drainage Criteria Manual. 3. As stated above, portions of the subject property is located in a FEMA regulatory floodplain. 4. The proposed project does not propose to modify any natural drainageways. F. Floodplain Regulations Compliance The development will be in compliance with Chapter 10 of City Code. As previously mentioned, all structures are located outside of the Cache La Poudre 100-year floodplain, however the lots removed by LOMR-F are subject to the elevation requirements. Extra care has been taken to ensure that neither existing nor proposed structures will suffer damage during the 100-year storm as a result of the proposed development. 2. Stabilization measures are currently being proposed along the bend in the Cache La Poudre River northwest of the project site. All stabilization design work is being conducted by the City of Fort Collins. 3. Critical facilities are prohibited within the 100-year and 500-year flood fringe. 4. A floodplain use permit must be obtained prior to any work to be done within the floodplain prior to construction. A no -rise certification must be completed for any work to be done within the floodway prior to construction. A floodplain use permit is required for each house built in the LOMR-F area (Lots 9 — 14, and Lots 31 — 33) 5. No floatable items are proposed within the floodway. Any floatable items within the floodway must be anchored to prevent flotation. All fencing within the floodway will consist of a break -away design. 6. A FEMA elevation certificate must be reviewed and approved prior to issuance of a Final Drainage Report 9 NORTHERN ENGINENORT QRINO 1 1 1 certificate of occupancy (C.O.) for any homes built in the LOMR-F area. 7. A post -construction no -rise certification is required for any work in the floodway. G. Modifications of Criteria 1. The proposed development is not requesting any modifications to criteria at this time. IV. DRAINAGE FACILITY DESIGN A. General Concept 1. The main objectives of the project drainage design are to maintain existing drainage patterns, and to ensure no adverse impacts to any adjacent properties. 2. The existing pond to the south of the site historically drains through the project site. Off -site drainage flows and patterns will be maintained and accounted for with the proposed development. 3. A list of tables and figures used within this report can be found in the Table of Contents at the front of the document. The tables and figures are located within the sections to which the content best applies. 4. The drainage patterns anticipated for proposed drainage basins are described below. Basin 1 ' Basin 1 consists of backs of proposed residential lots. This basin will be allowed to sheet flow across a large natural vegetated buffer prior to entry into the Cache La Poudre River, just to the north of this basin. Due to reduction in area draining directly ' to the Cache La Poudre River, Historic 2-, 10-, and 100-year flows will be reduced. 2-yr Flow 10-yr Flow 100-yr Flow ' (cfs) (cfs) (cfs) Historic Cond. 1.01 1.72 4.53 ' Proposed Cond. 0.42 0.72 1.86 Basin 2 ' Basin 2 consists of residential lots and proposed street/sidewalk. This basin will drain via street curb and gutter to a proposed storm sewer system and into the proposed water quality forebay to be located just west (upstream) of the existing wet pond. Basin 3 Basin 3 consists of residential lots and proposed street/sidewalk. This basin will drain ' via street curb and gutter to a proposed storm sewer system and into the proposed water quality forebay to be located just west (upstream) of the existing wet pond. Basin 4 Basin 4 consists of backs of residential lots and an open area behind lots. This basin will drain via swale and then via street curb and gutter to a proposed storm sewer system and into the proposed water quality forebay to be located just west (upstream) of the existing wet pond. Final Drainage Report 10 I 1 1 NORTHERN ENGINEERING Pateros Creek Basin 5 Basin 5 consists of residential lots and proposed street/sidewalk. This basin will drain via street curb and gutter to a proposed storm sewer system and into the proposed water quality forebay to be located just west (upstream) of the existing wet pond. Basin 6 Basin 6 consists of residential lots and proposed street/sidewalk. This basin will drain via street curb and gutter to a proposed storm sewer system and into the proposed water quality forebay to be located just west (upstream) of the existing wet pond. ' Basin 7 Basin 7 consists of backs of residential lots. This basin will be allowed to sheet flow across a large natural vegetated buffer area. The length of this area is sufficient that ' we believe all storm runoff will infiltrate or be captured in localized depressions prior to entry into the Cache La Poudre River. ' Basin OS-1 Basin OS-1 has been created by the improvements to take place in Wood Street. Wood Street will be paved, and a high point in the roadway will be created such that there will now be a 0.10 acre basin that drains to an existing inlet on the west side of ' Wood Street (at the southwest corner of Basin OS-1). This area of 0.10 is insignificant relative to the overall basin draining to the existing inlet, and will create negligible impact to the existing inlet and receiving storm drain. ' A full-size copy of the Drainage Exhibit can be found in the Map Pocket at the end of this report. ' B. Specific Details 1. Water quality treatment is being provided for the proposed development in the form of ' a water quality forebay as previously described. This water quality forebay will function as a constructed wetland. Please see calculation of water quality capture volume for a constructed wetland (UDFCD procedures) in Appendix C. ' A final copy of the approved SOP manual shall be provided to City and must be maintained on -site by the entity responsible for the facility maintenance. Annual reports must also be prepared and submitted to the City discussing the ' results of the maintenance program (i.e. inspection dates, inspection frequency, volume loss due to sedimentation, corrective actions taken, etc.). ' 2. Table 2, below, summarizes the water quality information for the proposed water quality pond. Table 2 —Water Quality Pond (Forebay) Summary ' Water Quality Water Quality Pond Spillway Top of Pond Capture Volume (Constructed Wetland) WSEL Elevation Elevation ' (AC -FT) (FT) (FT) (FT) 0.110 4970.54 N/A 4971.0+/- ' 3. Proper maintenance of the drainage facilities designed with the proposed development is a critical component of their ongoing performance and effectiveness. ' Final Drainage Report 11 .V NORTHERN ' ENGINEERING Pateros Creek ' The water quality forebay may be easily accessed by maintenance staff via the gentle slope provided to the bottom of the pond. 4. The drainage features associated with the proposed project are all private facilities, located on private property. 5. The proposed outfall for the majority of the site is the existing wet pond at the southeast corner of the site. This wet pond has drains via an existing 24-inch pipe into a swale, which conveys flows northeast to the Cache La Poudre River. Stacked detention (detention over the permanent water surface elevation) within the existing wet pond is proposed in order to maintain capacity within the receiving offsite swale. ' Calculations provided in Appendix C show a detention volume of 0.94 acre-feet with a peak 100-year release rate of 1.30 cfs, and a water surface elevation of 4971.54. This is naturally occurring detention, as the outfall for the pond (existing 24-inch pipe) ' limits oufflow. Detention is not a requirement due to the site's proximity to the river. Therefore, we are not referring to this area as a "Detention Pond". ' V. CONCLUSIONS A. Compliance with Standards ' 1. The drainage design proposed with the proposed project complies with the City of Fort Collins' Stormwater Criteria Manual. 2. The drainage design proposed with this project complies with the Old Town Master ' Basin (City of Fort Collins, July 2003). 3. The drainage plan and stormwater management measures proposed with the ' proposed development are compliant with all applicable State and Federal regulations governing stormwater discharge. 4. The proposed development is in compliance with Chapter 10 of City Code. ' B. Drainage Concept 1. The drainage design proposed with this project will effectively limit any potential damage associated with its stormwater runoff by providing detention and a water quality forebay. 2. The drainage concept for the proposed development is consistent with the Old Town ' Master Basin (City of Fort Collins, July 2003). Final Drainage Report 12 1 1 1 1 1 NORTHERN ENGINEERING References Pateros Creek 1. City of Fort Collins Landscape Design Guidelines for Stormwater and Detention Facilities, November 5, 2009, BHA Design, Inc. with City of Fort Collins Utility Services. 2. Fort Collins Stormwater Criteria Manual, City of Fort Collins, Colorado, as adopted by Ordinance No. 174, 2011, and referenced in Section 26-500 (c) of the City of Fort Collins Municipal Code. 3. Latimer County Urban Area Street Standards, Adopted January 2, 2001, Repealed and Reenacted, Effective October 1, 2002, Repealed and Reenacted, Effective April 1, 2007. 4. Soils Resource Report for Latimer County Area, Colorado, Natural Resources Conservation Service, United States Department of Agriculture. 5. Urban Storm Drainage Criteria Manual, Volumes 1-3, Urban Drainage and Flood Control District, Wright -McLaughlin Engineers, Denver, Colorado, Revised April 2008. 6. Preliminary Subsurface Exploration Reoort 912 Wood Street November 17 2011, Earth Engineering Consultants, Inc. Final Drainage Report 13 APPENDIX A HYDROLOGIC COMPUTATIONS �ƒ||§j q / ° §§ ° § : ( ° do § \E LL.�`���� - �2) 2-; ° k - LEA as 00 00 _ � 00 2 - / e 00 § �. � _ $-«°§ § 2 ! !>!»« - § ) S _ \(}00 ƒ is 0 . / Ly 2 /! } 0 0 \ § - /� ��00-- � 3 S N n LL CF n n M N ti 3 O V � Q � T r e u A tO C 2 C + O O C C $ N 4 GYGYGY NN o 0 0 `O q V G = 0 LA O T Vyy U O O Zcc S u o C O Q �i �nn�6 ri _ o E 0 O 2 0 e � E a .y rNi U C 0 a = A i lO l0 LL s o � O � N WL' N c r v _ K R' ¢ t U d° m o N _ � d A-� V ti p '-' ?`yC .v n Nlnmm�e b W n 1I1 N in Z o o E rc o 0 0 0 0 0 0 0 Q O m ^ U U 1m0¢ 6 d J ym- YO � NN't � rbOf ONmN N Y n V U � a' b r n l0 Ol O N m N N U $ NE�i vb 6000000 In lqm 0 iz U U v c _ d 01b btTbO n Q q9 00000ti0 < O �9 A'o a n `o ry 0000000 0 0000000 0 �uZ 0mamry 00E A o000000 0 a E � Qu`"' o000000 0 01 � � Z� 1n Of in oleo O 1n 1n N a y1 A O Y pro mou°iim m y ,t,t yam, y 00000 00 O O O O v Q m" N O O N m O O N Q O O O O 10 U n 9 2^ momm mloa o 0 a .g �'' 0--000 o000000 0 0 ^ 0o Inoo 00 1n U) A,cA obm 00 olYoo ry y a�' 0000000 4 � g E o v V c °l vai 'm gminm ry p =_ m O d r W Q A a� m � LU i cbumv ro.n. 1°m m m c m m Q i A U 1y N U K 6 N m Q Q U' V 3 La U NS O b u o u E N ti O E N r n o E z z z m z z z n A i< <O q u e> LL i 6 <<< e O< 6 6 A N A N Z Z Z O Z Z Z $N 0 0 0 0 00 u y J c ¢ '^. in ¢ v Iq o E z of z w of -. c 'u g a z v a a o > 0 O LL> C CC000, 00 OI� C U N VI a O 0 N O u0i � R r„ 01010 O O 00 gN9 2 a C C1Jz O o m, u a� J Z V Of m^ .m. lAetl o r c 'o v a m m m o Q e o Li ui Q N o O z c 'R v o O1 N v W rvE H e O O O O 000 f0 O LL 9 Ly O C J� a a0 Q N O Z O J N O y N N 0 0 V 0 v VOII o000 0 0 T O ti `s . ry O' 'i V Lq m io m A U II 0 0 0 0 0 0 0 w V g LT T O n b Of O N m N L 0000000 mm0 b u x x J U U N O ti o Win. U (/�S OLL, >> } J N Z Z Z Z Z Z Z 0 YW d q H N m V In l0 n 00 3 oe r'-n Of N W M N n N LL LL O + O M O p " o O u 0 O -• -• O lmD Q Q YT � m Y ^F O C N O N O al N N LL Y - C 2 Y- V n N lD Ol lD 1p N� n N lO N _ C U m N 01 N m M l0 C o C n yy m bH M O N 0 N 0 n 0 M 0 n 0 V 00 ooye� V 1 a N N Ol O N M N O o 0 0 0 0 0 0 Z .7 O L O o u •n+ a Lq O llp m -N4 o o 0 o 000 eg W p g g33 m T E .. a z o 5. c N DJ V M N u'J - cam'@ V glT N N C— M N E N E O -y ONO C O = C ^ ^ V O q W = t m y Y m� o a 1 1 1 1 i 1 1 1 1 1 1 1 1 1 / Tom- UAkll11J /// SS- -.ALL -11/Il�ifi > _ U) f/ ao oz� ?071n 0 (S31HVA MOH) »v 10 nnnnn O APPENDIX B HYDRAULIC COMPUTATIONS B.1 — Storm Sewers B.2 — Inlets 8.3 - Swales APPENDIX B.1 STORM SEWERS I I I I 1 LIN M O N N Cb O V N N C J O Z x N N to Z E E N N 11 U N .Q 9 x Storm Sewer Summary Report Page 1 Line Line ID Flow Line Line Invert Invert Line HGL HGL Minor HGL Dns No. rate size length EL Dn EL Up slope down up loss Junct line Mal (in) (ft) (ft) (ft) N (ft) (ft) (ft) (ft) No. 1 Pipe - (20) 7.90 18 c 39.8 4969.60 4969.78 0.451 4970.67 4971.04 0.19 4971.23 End 2 Pipe - (21) 7.90 18 c 75.0 4969.78 4970.12 0.454 4971.31 4971.62 0.25 4971.87 1 3 Pipe - (22) 7.90 18 c 86.5 4970.12 4970.51 0.450 4971.87' 4972.28' 0.10 4972.38 2 4 Pipe - (23) 3.60 15 c 38.0 4970.51 4970.68 0.449 4972.56' r 4972.66' 0.13 4972.80 3 Project File: stml.stm Number of lines: 4 Run Date: 08-26-2013 NOTES: c = cir; e = ellip; b = box; Return period = 10 Yrs. ;'Surcharged (HGL above crown). Hydmflow Storm Sewers 2005 ' m 1 I [1 10 20 O N C N m N O p Y voi m cN'� o T W N coo N m r N m O N M < N N Y L U ! N e N r aND N O N O O O O p m m m m C K (O e V O R N O O O O J! M M O O V m m m f7 m ^ W m� [V N m rn rn m a a a a WE M 7 7 O O O O V N m r r M m N d _ O E L Z G J! O m N m a v v a ! x c fi m rn rn m c J S m o m o Of YI (O c0 M r m M a N N N m < V N J ! O N m M N m m m rn rn m v a e a a L O O O C m m e e m m in m r m r r M p L o J (r0 M anD h v a a a o m N c m� m rn m m E Q O O O O m m rn m p N C N N - V d d C � APPENDIX B.2 INLETS INLET CAPACITY SUMMARY Project: 687-001 By: ATC Date: 8/15/2013 Inlet Inlet Inlet Design Design ID Type Condition Storm Flow Inlet Capacity (CFS) (CF5) 1-3 Single Combination Sump 10- r 4.30 8.70 1-4 Single Combination Sump 10- r 3.60 8.70 INLET IN A SUMP OR SAG LOCATION Pm)M • Combination Inlet Capacity total ID = Single Combination Inlet - Sump Condition {—lo (C)� H-Corp H-Vane Wd Wp W to lG) in Morm•Ibn thei of Win INat Type = Depression (addMonaitocotirtwln gutter depression'a'train n-AOOW) ew,r er of Unit IN. (Grate or C. OPoNn,) No - Denton at RoWale (oLLeba of but depression) Fbw Depin bformalbn Hof a Unit G. 4 (G)- of a UM Grale W.= Diem, Ratio for a Grate(ypcel vales 0.15 W) A— in, Fr for o Single Grate (ypul vole 05D- D.TO) CG (G)= Weir Caetfdart (ypcal vale 2,15-3.W) C. (G)= Odtlw Coettldan (typical value n60.0AD) C. (G)' Opening Information IOf a UNI Curb Otamrg 4 (C)= 1 of Vanua' cure OWNlg In Inct H. t at Cure Orifice Throat in loons Ha..•= of Throot (see USDCM Fr,se STS) Tirana= ,eh far Daprasbn Pant al,* Net X. wbp of 2 feet) Wa- in, Fetlor far a SYgk C. Opener, (ly(Yal. GAG) CI (C)= Diener, War CoalrnM(trpiul vale 2.".6) C.(C)= 3pamn, Ordioa Coefficient (ypcal vale 0 so.0.70) C. (C)= A Inlet Interception Capacity (assumes clogged condition) Q. VWG: Inlet CapacXy Was then O Peak for Manor and Major Stoma Oseynasouaeo' MINOR MAJOR Denier No. 16 COmlamat,an zoo 200 Ii-No 1 I IrcFes 6e 1z0 MINOR MAJOR 3.00 3W feel 1]3 173 ee 0,31 0.31 0.50 0.50 3.60 3On 0B0 060 MINOR MAJOR 3.00 Soo 6.W 650 525 525 DOW 000 zip zoo 0,10 0.10 3.70 370 o 66 066 fare miles wiles degrees feel UD Inlet 3. 1 ranbolnletaingle, Inlet In Sump 7I26I2013, 1:51 PM APPENDIX B.3 SWALES I� RATING CURVE FOR TRAPEZOIDAL CHANNEL �I o.W v.. rmw zw - z. >g aw n.ro a ,o w zon zso zoo zco ,uo�la.l Bottom Width Left Side Slope Right Side Slope Manning's n or SCS Retardance Curve Longitudinal Slope B = 0.00 feet Z1 = 15.00 ft/ft Z2 = 15.00 ft/ft n = 0.035 S = 0.0125 ft/ft Flow Depth Y (ft) Manning's Roughness n Flow Area A (sq ft) Wetted Perimeter P (ft) Hydraulic Radius R (ft) Flow Velocity V (fps) Flow rate Q (cfs) Froude Number Fr 0.10 0.0350 0.15 3.01 0.05 0.6 0.1 0.51 0.20 0.0350 0.60 6.01 0.10 1.0 0.6 0.57 0.30 0.03501 1.35 9.02 0.15 1.31 1.8 0.61 0.40 0.0350 2.40 12.03 0.20 1.6 3.9 0.64 0.50 0.0350 3.75 15.03 0.25 1.9 7.1 0.66 0.60 0.0350 5.40 18.04 0.30 2.1 11.5 0.68 0.70 0.0350 7.35 21.05 0.35 2.4 17.3 0.70 0.80 0.0350 9.60 24.05 0.40 2.6 24.7 0.72 0.90 0.0350 12.15 27.06 0.45 2.8 33.8 0.73 1.00 0.0350 15.00 30.07 0.50 3.0 44.8 0.74 1.10 0.0350 18.15 33.07 0.55 3.2 57.7 0.76 1.20 0.0350 21.60 36.08 0.60 3.4 72.8 0.77 1.30 0.0350 25.35 39.09 0.65 3.6 90.2 0.78 1.40 0.0350 29.40 42.09 0.70 3.7 109.9 0.79 1.50 0.0350 33.75 45.10 0.75 3.9 132.1 0.80 1.60 0.0350 38.40 48.11 0.80 4.1 156.9 0.80 1.70 0.0350 43.35 51.11 0.85 4.3 184.4 0.81 1.80 0.0350 48.60 54.12 0.90 4.4 214.7 0.82 1.90 0.0350 54.15 57.13 0.95 4.6 248.0 0.83 2.00 0.0350 60.00 60.13 1.00 4.71 284.4 0.84 2.10 0.0350 66.151 63.14 1.05 4.91 323.9 0.84 SWALE 1: Q100=12.9 cfs --> d=0.65' 0100'1.33=17.2 cfs --> d=0.70' UD-Channels_v1.04-swale 1, Rating 8/27/2013, 1:34 PM 0 6.0 a 5.0 E z z 4.0 m �o LL 3.0 19 - 2.0 0 1.0 m 0.0 0.00 0 6.0 6 5.0 z m v p 4.0 U. wa 3.0 T 0 2.0 d 1.0 0.0 IN 0 RATING CURVE FOR TRAPEZOIDAL CHANNEL Velocity, Froude Number, & Manning's n vs. Flow Depth VR Product 1 2 3 4 5 0.50 1.00 1.50 2.00 Flow Dapth (R) �Veloclty(fps)-0--Froude Number-t-Manning'sn Velocity, Flow Depth, Froude Number & Manning's n vs. Discharge VR Product 1 2 3 4 5 50 100 150 200 250 300 Flow Rate In e1s Flow Depth -+-Velocity -w-Froude No.-t-Manning's n 6 0.040 0.035 0.030 0,025 L]c 0.020 0.015 0.010 0.005 0.000 2.50 6 0.040 0.035 0.030 0,025 c p 0,020 c C 0.015 0.010 0.005 0.000 350 UD-Channels_0.04-swale 1, Rating 8/27/2013, 1:34 PM APPENDIX C DETENTION AND WATER QUALITY DESIGN COMPUTATIONS I 1 1 1 1 I 1 11 DETENTION POND CALCULATION; FAA METHOD Project Number 687-001 Project Name Pateros Creek Project Location Fort Collins Calculations By: ATC Pond No : Exist. Wet Pond Input Variables Results Design Point Overall Design Storm 100-yr Developed "C" = 0.52 Area(A)= 7.32 acres Max Release Rate = 1.30 cfs Required Detention Volume 41067 ft' 0.94 ac-ft Time Time 100-yr Intensity Q100 Inflow (Runoff) Volume Outflow (Release) Volume Storage Detention Volume mins secs in/hr cfs (ft) (ft) I (ft ) 5 300 9.950 37.87 11362 390.0 10972.1 10 600 7.720 29.39 17631 780.0 16851.2 15 900 6.520 24.82 22336 1170.0 21166.0 20 1200 5.600 21.32 25579 1560.0 24019.0 25 1500 4.980 18.96 28434 1950.0 26483.8 30 1800 4.520 17.20 30969 2340.0 28628.9 35 2100 4.080 15.53 32613 2730.0 29883.2 40 2400 3.740 14.24 34166 3120.0 31046.2 45 2700 3.460 13.17 35559 3510.0 32049.4 50 3000 3.230 12.29 36884 3900.0 32984.0 55 3300 3.030 11.53 38060 4290.0 33770.2 60 3600 2.860 10.89 39191 4680.0 34510.7 65 3900 2.720 10.35 40378 5070.0 35308.3 70 4200 2.590 9.86 41406 5460.0 35946.0 75 4500 2.480 9.44 42479 5850.0 36629.4 80 4800 2.380 9.06 43484 6240.0 37244.3 85 5100 2.290 8.72 44455 6630.0 37824.9 90 5400 2.210 8.41 45426 7020.0 38405.6 95 5700 2.130 8.11 46214 7410.0 38803.5 100 6000 2.060 7.84 47047 7800.0 39247.1 105 6300 2.000 7.61 47961 8190.0 39770.6 110 6600 1.940 7.38 48737 8580.0 40157.1 115 6900 1.890 7.19 49639 8970.0 40669.3 120 7200 1.840 7.00 50427 9360.0 41067.2 ' C:\NE\687-001-Pateros Creek\Drainage\Detention\DetentionVolume_FAA Method 3/12/2013 Culvert Designer/Analyzer Report Pond Outlet Analysis Component Storm. Event Design Discharge 10.00 cfs Peak Discharge, Method: User -Specified Design Discharge 10.00 cfs Check Discharge 5.00 cfs Tailwater Conditions: Constant Tailwater Tailwater Elevation N/A ft Name Description Discharge HW Elev. Velocity Culvert-1 1-24 inch Circular 10.00 cis 4,971.83 ft 7.98 t$s Weir Not Considered N/A N/A N/A Project Engineer: Northern Engineering Services d:\...\drainage\culverts\wet pond outlet.cvm Northern Engineering Services CulvertMaster v2.0 (2.0051 03/12/13 01:08:15 PM Q Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA +1-203-755-1666 Page 1 of 2 Culvert Designer/Analyzer Report Pond Outlet Component Culvert-1 Culvert Summary Computed Headwater Elevat Inlet Control HW Elev. Outlet Control HW Elev. Headwater Depth/Height 4,971.83 ft 4,971.67 ft 4,971.83 ft 0.91 Discharge Tailwater Elevation Control Type .Entrance 10.00 cfs N/A ft Control Grades Upstream Invert Length 4',970.00 it 24.00 it Downstream'lnvert Constructed Slope 4,969.50 It 0.020833 %I t Hydraulic Profile Profile S2 Slope Type Steep Flow Regime Supercritical Velocity Downstream 7.98 ft/s Depth, Downstream Normal Depth Cdtical:Depth Critical: Slope. 0.84 it 0.76 it 1.13 It 0.005202 11M Section Section Shape Section Material Section Size Number Sections Circular Concrete 24 inch 1 Mannings Coefficient Span Rise 0.013 2.00 it 2.00 ft Outlet Control Properties Outlet Control HW Elev. Ke 4,971.83 ft 0.50 Upstream Velocity Head Entrance Loss 0.46 It 6.23 ft Inlet Control Properties Inlet Control HW Elev. 4,971.67 ft Inlet Type Square edge w/headwall K 0.00980 M 2.00000 C 0.03980 Y 0.67000 Flow Control Area Full HOS 5Chart HDS 5Scale Equation Form Unsubmerged 3.1 ft' 1 1 1 Project Engineer: Ncrthem Engineering Services d:�..ldrainage%cutvertslwet pond cutlet.cvm Northam Engineering Services CulvertMaster v2.0 [2.006] 03/12A3 01:08:15 PM m Haestad Methods., Inc. 37 Brookside Road Waterbury, CT06708 USA •1-203-755-1666 Page 2 of 2 I I n I [J 1 I 1 1 Rating Table Report Pond Outlet Range Data: Minimum Maximum Increment Allowable HW E 4,969.50 4,971.50 0.10 ft HW Elev. (11) Ascharge (cis 4.969.50 0.00 4,969.60 0.00 4,969.70 0:00 4,969.80 0.00 4,969.90 0.00 4,970.00 0.00 4,976.10 0.04 4,970.20 0.15 4,970.30 0.34 4,970.40 6.59 4,970.50 6.91 4,970.60 1.30 4,970.70 1.75 4,970.80 Z25 4,970.96 2.81 4,971.00 3.42' 4,971.10 4.08 4,971.20 4.79 4,971.30 5.54 4,971.40 6.32 4,971.50 7.14 Project Engineer: Ncrthem Engineering Serrices d1... ldtainegeNcuNertshvet pond cutlet.cvm Northam Engineering Services CulvertMaster v2.0 [2.005] 03/12/13 01:08:42 PM ®Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA a1-203-755-1666 Page 1 of 1 1 1 1 1 1 1 1 1 1 1 1 1 i 1 1 1 1 1 1 QUALITY POND ATC BASIN AREA = 7.320 <— INPUT from impewiouscalcs BASIN IMPERVIOUSNESS PERCENT= 41.00 <— INPUT from impervious calcs BASIN IMPERVIOUSNESS RATIO = 0.4100 <—CALCULATED WQCV (watershed inches) = 0.182 <-- CALCULATED from Figure EDB-2 (24 In drain time) WQCV (ac-ft) = 0,111 <—CALCULATED from UDFCD DCM V.3 Section 6.5 WQ Depth (ft) = N/A** <-- INPUT from stage -storage table AREA REQUIRED PER ROW, a (in2) = N/A** <—CALCULATED from Figure EDB-3 CIRCULAR PERFORATION SIZING: dial (in) = N/A** <-- INPUT from Figure 5 n = N/A** <-- INPUT from Figure 5 f (in) = N/A** <— INPUT from Figure 5 number of rows = N/A** <-- CALCULATED from WO Depth and now spacing 1 1 1 1 1 1 1 1 Water Quality Pond Foreba Volume Calculations Project: 687-001 By: ATC Date: 8.1.13 Note: Volume calculations utilize Conic Method Pond Stage Depth F Surface Area of Contour SF Incremental Volume CF Total Volume C Total Volume AF 4969 0.00 2990 4970 1.00 4310 3626 3626 0.083 4970.54" 0.50 5796 2515 6141 0.110 4971 0.50 5796 2515 6141 0.141 "Interpolated 100-year WSEL APPENDIX D EROSION CONTROL REPORT i RV (NORTHERN ENGINEERING I� EROSION CONTROL REPORT A comprehensive Erosion and Sediment Control Plan (along with associated details) has been included with the final construction drawings. It should be noted, however, that any such Erosion and Sediment Control Plan serves only as a general guide to the Contractor. Staging and/or phasing of the BMPs depicted, and additional or different BMPs from those included may be necessary during construction, or as required by the authorities having jurisdiction. ' It shall be the responsibility of the Contractor to ensure erosion control measures are properly maintained and followed. The Erosion and Sediment Control Plan is intended to be a living ' document, constantly adapting to site conditions and needs. The Contractor shall update the location of BMPs as they are installed, removed or modified in conjunction with construction activities. It is imperative to appropriately reflect the current site conditions at all times. ' The Erosion and Sediment Control Plan shall address both temporary measures to be implemented during construction, as well as permanent erosion control protection. Best Management Practices from the Volume 3, Chapter 7 — Construction BMPs will be utilized. Measures may include, but are ' not limited to, silt fencing along the disturbed perimeter, gutter protection in the adjacent roadways and inlet protection at existing and proposed storm inlets. Vehicle tracking control pads, spill containment and clean-up procedures, designated concrete washout areas, dumpsters, and job site ' restrooms shall also be provided by the Contractor. Grading and Erosion Control Notes can be found on the Utility Plans. The Final Plans contain a full-size Erosion Control sheet as well as a separate sheet dedicated to Erosion Control Details. In ' addition to this report and the referenced plan sheets, the Contractor shall be aware of, and adhere to, the applicable requirements outlined in the Development Agreement for the development. Also, the Site Contractor for this project will be required to secure a Stormwater Construction General ' Permit from the Colorado Department of Public Health and Environment (CDPHE), Water Quality Control Division — Stormwater Program, prior to any earth disturbance activities. Prior to securing ' said permit, the Site Contractor shall develop a comprehensive StormWater Management Plan (SWMP) pursuant to CDPHE requirements and guidelines. The SWMP will further describe and document the ongoing activities, inspections, and maintenance of construction BMPs. 1 1 1 1 Final Drainage Report APPENDIX E SUPPLEMENTAL INFORMATION: FEMA FIRMETTE, LOMR-F w LdE d EEa OM- ° p C�° W� Wg y EE �a$E W W n`iP Zm W i l C9 p� Q �dF 8FS Sm �' E3 eg �zo 8� o N S o V a Z;R �9g g 88f Z SEHq$ tE u. �g z x e R$ a CC Z w p o f �! `1/ °�w 'Sf Eiic d _ _ E °@axE •9pEM2 rt LE :z ` �nssb` '+«_ = I i t i r".t+1Ei w. °i S :rt ! I' � i i ♦ �% r- I t., •N t t •e. r n `r M r `ii ♦� w ......... W t By kZ r S9lt-.. N k - ,�' 3nN3AVSIWOOI I r t t ` _ NSF 3nN3AV 1NVa`J is 086bk # 3 ' i r, Z w :r t iris } O F ,1866; ii «.I — 133a1S h ❑OOM Z Z x w w XIT, > idnoo i" W13 133a1S •' • }2� > HaVd a1S a t _ NaVd t .. •:• — 3�Vld ,L�Q,�6� r -I ei}• Nlddla`J Page 1 of 2 Date: March 22, 2012 Case No.: 12-08-0323A LOMR-F O�4A���~� 9 Federal Emergency Management Agency 9°cF go-` Washington, D.C. 20472 ��Hm sEc LETTER OF MAP REVISION BASED ON FILL DETERMINATION DOCUMENT REMOVAL COMMUNITY AND MAP PANEL INFORMATION LEGAL PROPERTY DESCRIPTION LARIMER COUNTY, COLORADO A portion Of Section 2, Township 7 North, Range 69 West, 6th P.M., (unincorporated Areas) as described in the Special Warranty Deed recorded as Reception No. 20110057190, in the Office of the Recorder, Latimer County, COMMUNITY Colorado. The portion of property is more particularly described by the following COMMUNITY NO.: 080101 metes and bounds: NUMBER: 08069CO977G AFFECTED MAP PANEL DATE: 6/17/2008 FLOODING SOURCE: CACHE LA POUDRE RIVER APPROXIMATE LATITUDE 8 LONGITUDE OF PROPERTY: 40.600,-105.088 SOURCE OF LAT 8 LONG: GOOGLE EARTH PRO DATUM: NAD 83 DETERMINATION OUTCOME 1%ANNUAL LOWEST LOWEST WHAT IS CHANCE ADJACENT LOT LOT BLOCK/ SUBDIVISION STREET REMOVED FROM FLOOD FLOOD GRADE ELEVATION SECTION THE SFHA ZONE ELEVATION ELEVATION (NAVD 88) NAVD 88) (NAVD 88 -- — — 912 Wood Street Portion of X 4976.8 to — 4976.9 to Property (shaded) 4978.1feet 4978.2feet Special Flood Hazard Area (SFHA) - The SFHA is an area that would be inundated by the flood having a 1-percent chance of being equaled or exceeded in any given vear (base flood). ADDITIONAL CONSIDERATIONS (Please refer to the appropriate section on Attachment 1 for the additional considerations listed below.) LEGAL PROPERTY DESCRIPTION FILL RECOMMENDATION PORTIONS REMAIN IN THE SFHA This document provides the Federal Emergency Management Agency's determination regarding a request for a Letter of Map Revision based on Fill for the property described above. Using the information submitted and the effective National Flood Insurance Program (NFIP) map, we have determined that the described portion(s) of the property(ies) is/are not located in the SFHA, an area inundated by the flood having a 1-percent chance of being equaled or exceeded in any given year (base flood). This document revises the effective NFIP map to remove the subject property from the SFHA located on the effective NFIP map; therefore, the Federal mandatory flood insurance requirement does not apply. However, the lender has the option to continue the flood insurance requirement to protect its financial risk on the loan. A Preferred Risk Policy (PRP) is available for buildings located outside the SFHA. Information about the PRP and how one can apply is enclosed. This determination is based on the flood data presently available. The enclosed documents provide additional information regarding this determination. If you have any questions about this document, please contact the FEMA Map Assistance Center toll free at (877) 336-2627 (877-FEMA MAP) or by letter addressed to the Federal Emergency Management Agency, LOMC Clearinghouse, 7390 Coca Cola Drive, Ste 204, Hanover, MD 21076. Luis Rodriguez, P.E., Chief Engineering Management Branch Federal Insurance and Mitigation Administration Page 2 of 2 Date: March 22, 2012 Case No.: 12-08-0323A LOMR-F oeenr�i j� Federal Emergency Management Agency Washington, D.C. 20472 LETTER OF MAP REVISION BASED ON FILL DETERMINATION DOCUMENT (REMOVAL) ATTACHMENT 1 (ADDITIONAL CONSIDERATIONS) LEGAL PROPERTY DESCRIPTION (CONTINUED) COMMENCING at the southwest sixteenth corner of Section 2; thence N82e46'17"E, 742.17 feet to the POINT OF BEGINNING; thence S72029'58"E, 11.00 feet; thence S61100'36"E, 56.26 feet; thence S45051'29"E, 28.00 feet; thence S11034'53"E, 12.83 feet; thence S33046'31"E, 57.28 feet; thence S19136'59"E, 10.57 feet; thence S41014'18"W, 13.40 feet; thence S53e25'50"W, 5.22 feet; thence S23e39'30"W, 3.62 feet; thence S06029'07"E, 16.57 feet; thence S01e58'10"W, 5.67 feet; thence S31019'01"E, 15.75 feet; thence S73e17'41"E, 25.80 feet; thence S50e36'37"E, 4.30 feet; thence S18e08'58"E, 18.35 feet; thence SO4°38'57"W, 8.51 feet; thence S26003'53"E, 74.26 feet; thence S12e18'35"E, 42.71 feet; thence S01004'35"E, 20.34 feet; thence S19040'18"E, 54.06 feet; thence S34e19'30"E, 20.20 feet; thence S37e32'20"E, 22.09 feet; thence S89055'53"W, 194.56 feet; thence N21e43'47"W, 171.33 feet; thence N33007'30"W, 110.80 feet; thence N27e04'37"E, 191.50 feet to the POINT OF BEGINNING. FILL RECOMMENDATION (This Additional Consideration applies to the preceding 1 Property.) The minimum NFIP criteria for removal of the subject area based on fill have been met for this request and the community in which the property is located has certified that the area and any subsequent structure(s) built on the filled area are reasonably safe from flooding. FEMA's Technical Bulletin 10-01 provides guidance for the construction of buildings on land elevated above the base Flood elevation through the placement of fill. A copy of Technical Bulletin 10-01 can be obtained by calling the FEMA Map Assistance Center toll free at (877) 336-2627 (877-FEMA MAP) or from our web site at http://www.fema.gov/mit/tb1001.pdf. Although the minimum NFIP standards no longer apply to this area, some communities may have floodplain management regulations that are more restrictive and may continue to enforce some or all of their requirements in areas outside the Special Flood Hazard Area. PORTIONS OF THE PROPERTY REMAIN IN THE SFHA (This Additional Consideration applies to the preceding 1 Property.) Portions of this property, but not the subject of the Determination/Comment document, may remain in the Special Flood Hazard Area. Therefore, any future construction or substantial improvement on the property remains subject to Federal, State/Commonwealth, and local regulations for floodplain management. This attachment provides additional information regarding this request. If you have any questions about this attachment, please contact the FEMA Map Assistance Center toll free at (877) 336-2627 (877-FEMA MAP) or by letter addressed to the Federal Emergency Management Agency, LOMC Clearinghouse, 7390 Coca Cola Drive, Ste 204, Hanover, MD 21076. Luis Rodriguez, P.E., Chief Engineering Management Branch Federal Insurance and Mitigation Administration MAP POCKET DRAINAGE EXHIBITS \ , I I I 1 1 , , 1 1 1 , I 1 I 1 I INN \ / rr_r .............. ja Ly\�----- \ oftft 00 OWNER NAUTA CHARLES R/CONNIE L- 802 WOOD ST. FORT COLLINS, I NORTH 80 0 50 IM MEW N FEET n 1 ,h - 60 IL LEGEND: vN000sED STCNx YxEx PROPOSED NEED Emil PROPOSED CONDCUR s3 ExiSnw CONTOUR- — — FItCPosED sWAUE PRCFOSED WHO R GUr — PROPERLY BOUeuwv — — DESIGN PgxT Q FECW ARROW ry 4=m MANAGE BASN LABEL Z .Q.in DRAINAGE BEEN BOUNDARY PROPRJD SWALE SECPW FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION «LEDN,r �r� a,EaoF Nmw. WnarshClow. Call Demre rw Dig. City of Fart Call [TfILITY PLAN APPROVED. May O-vv O -,-.Ea WE tt . ....E...W Ulty D.,. LnEIXEC BY:maoi y 0.Y CHECKED BY CHECKED BY: RNIe ee w 0.M CHECKED By Z� ujZ oZ Z W !! gggggggggggg 7� re II 7 LLI W Q c U z 0 w W Q U d O U) �y Sheet H1 Of 9 Sheets I f i t 3E \ IO.C/RN/ L G O 930N SMEL..SST FORT LOLL NO Ili OWNER CIT'OF FORT CIX INS \ IJY fjI �nLlp "LAPORTE AVE FORT W521COLLINS, co eosr � .r 111I SI,!%rrrl. nr rNu \ �HMs�� \\ ; .,.ILA— .• Ar J QI rV NS UIYQ'FPPTLpLM I xYT, — Lam■ I OWNER ■ ■ -_ NAUTA GYRLES 2LPVNIEL BOZ WOOD ST ■ FgROIXLINS ■ COM511 ■ I 1 •' i'-_ I I I I r \\�' f rj i 1 , I I I I I ® NORTH IN 0 IN 1(p .WIM x ) 1 1C0 R LEGEND: PMCPOYO MIEI Rarasm c mxcwl11)uRlwe __—.Rv___— RGws SMNL PRaPG.an WAS s WTIw NKRERIY BWW0RY -— EASMG IPo YR Rtl OANN BWXONtY AY OS1xG RMERNINDS GE9w PCNT ILGW 1PRGW w MNNAGE BAMN VPFL LMNNAGE BAMN BWNDARY TR D MAU MCYM `A NOTES: I. m wcC ]AIM 6 TE I UBE mm Etli ALLCRIHF IISE WTM THE'RATMµ NMTA3 BIYEFR EGL.' IETER TO 0. M C IXMI111EN3 BY M6$.Y ♦ MIOS BIMINI EW ADDiMS1AL INFMMA ON FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION H m x w w Q QZ Q W H U) U. U. O OS1 INSTALLED HEWEETERRE RE�,u,Fn F�N MALAGASY > xeLmw pei�na`�`ronr'®r I i La 2 ARE no ChEn N()FEDDRn. `V-nSflflo KXEYR GUY R EAFTY OBSERVER) rn SXEvR rtw , `wwD�AwED,E�wwr S RwDN .I II I. AIII --- / I _ I I I I I 7r� >I 7AM" t / \ � m NI S \ 1 '\ A.t, snaTou FEW nl w-wnv BIB /TMCTD IyTl I _\ ® NORTH eD 0 Be ,m 1WF.n FBI N� (m ER C) n. LEGEND: sm \ \ E,DRNxAET PA'WeEO \ \ \ I wnROSED coxmuP \ FF4nuGwu,WP ____Jou_PERFORMED \ - SNAKE \ 13 l wOtEPn AS. I, wuNOwrITTEST FREDESTRAN ACCESS R.weTi/ AI - LIS, CHROWS RAN KJ � , , EA41M6,WW RPARMnl3NWir \ \\ EnmwcaooD..A. ea+�m9n It \ W41Mx[TI.w05 - N It EaACROEME ECTNBCOL) LOT D Y — — — — _ \ If(Rf(AL"xsawiwu,uTEO, $� T F98 eEvnnoe NAVDY 5003 \ FEW SAM FLOOD¢ENAiv1 BFIR NWWVY � \. - ,>fre >o 1 I FIELD SURVEY BY: _ - I J LOT" \ BENCHMARKS: ■Q� LDr \ \(FFE=Teaz� CEOPROCAMLES 0 ISM_ 7113ImIm RAM1�`s 'I r.;��!/'.I �\\\y\\\��� ►:Cl/l/0l� lLor,r- 1111 Lore 11 Lars Frt-rs ar -= J l rEID°)F'°'E^MO -GARBAGE _ A I II a Zc� x �z gg W Z V Zw I al 3� *WARNING a XINE nDx. LLy NOTES:`»,�,.A»rE d dA : ___ \� ' nvxWDDDINBRB BYMEILMN18911.OIC6 iCMFElrW,41 �' RECJADwG xANMLffARMaFRW m _ c �n�rTFO.,s�E,.E�Nrs o.PNLea B� _— FA'E'"mE'rvT'e'a`�i,00'�En'Esma":'rvwT�o..eNaorn § wIWVD29 Omn ` 'T.REaTAPEmL Am CONVERT TO THE HAVDtlMNN. SEENOTERIFEN wwLTINFORMATEON LOI LOT ELEVATIONS IR. ....� �ilNOw a..ONB�. paT�mEew'wmnn xw m� �owaE Nm s wue'nw °°"� � n pnwK NEE HOOKER HIRER oru xnss E �N .an � »�m 41As 1 Larl sn MGM BE Nnc mnMRS Wan, m a,v v nna o nEE .En» *PRESS WEALSK ME MKIPAD ace a+ar .snag LGRE31 OFFICE MEET MULLS 41 anu PFnOFHERBERT 4MM ""W "TERM D%II MCI s-fin _ uNAi ruTmr Ewm E vnc EwwExT )E B ETfV/.TM D Fat TT BRAD TELEX) E�C.Anom IRTD _ A DETAIL DrN`NG NEEDMCOD UNTY VERTcAL DATUM OF`FSEET(TABLE M oc A 5. )µD,DE�cTw�x� EQuESIGHFLOOR LVAT"o cuFLm SE RETESERVE REuNRom OR STRUCTURE OVER UCTON USEEFFORTIORTURNEr.BE RRONAS WHIR PI S, ff DUE) x THE COMPLAINWAVATION OR F AREA INTERVIEW BEFORE CERETIFICATE OfD URANc. is ISSUED FOR My STRUCTURE iw TDCIDE-ki OLFIFMEA m 8 SO FILL MAY ME FILLING IN WE FLOOOwAr A ASCRIBE CERTERCATON SELL BE FOR ALL WORK COMPLETED I N WE IN of REGIONAL THAI BE BREAK AR EAKEM"".R 10 NO S OUTSIDEuDE�DND FMATERALSORm"Ns"Kc;:va� c RA LLl WELL ALSO MEET WE AEWI Wa FOR NO RISE N ME aOOO.vAY. V Z NORTNERNENDwEERwD.OATEDAURURT2.=o13 FOR ADDiNOrvAL INFORMATION ODEVELOPED J 12 LOTS I AND 2 ARE LOCATED IN WE WERE VINE FLOODAILAY S STILL HE A HEN THE FLOTATIONS IS REBRAVED NO aN�° .,,N.LLBEALLOAEDDNELWEFCCOWAvsMENDVED W a Pat FEW CASE 01 NGELOULLA RATED NEWARK OF �� _R MEN REMOVED FROM WE AREA BALANCE) REVEAL o DDDnNN WE mx uan.�mNSnawm d Q CONSTITUTION O J City of Fort Collins. Colorado UTrLITY PLAN APPROVAL APPROVED: ARE Ems... o.v CHECKED BY. ..W 6 lTmlmM WERE Y CAUSED) DY ED av EMCKEED BY rN,k, & BENI oII CHECKED B'S DIRECTED BC,� DLLN, LL Sheet FLOOD Of 28 Sheets EXISTING Froi FOUFLO DI FE EXISTING BOANDARY Pi RNER OWMER: KARMA. LLVINGSTON ON SHIFIAS ST FORTCOLLLNS, IDE)Sk f L OWNER- _ CI]YCFF CIXLINS ^ \ PoROS(Mo \ FCFTCOWNS. \ VIVIVIV \ \ \ \ Ai FIVE. \ \ I AN nMYAT®Eul<OMr� \ I Grp T�Ro �wmorar°aovWA. . FIX pd,vreleR 1 �uRTw �m.ncmrrwim V lo-ApanVVV FIX, V,I FLaaISlxlluM4�Dwr — nnoDR wm IN 1 ------ -- —monam VIA T- �oT.— _�B -- — fora _ �or]— 1' -- -- � a ` nuw�rnvmw 2 VA LOTa ` � — TS( I NSL E� - -� ♦ 1 .LOT 10 LOTLS ♦ OT 20 OWNER: CITY CF FWtT CgLINS "LAPORTEAVE W FORT couM+S F w M52T y / I I F2 r �IIY q'i mAa \ „R9IlA2Eo RA�1 a � I �, Ed (F.19FF1[1 F —, AN -IATS LM'tl Lorm 2p LOFm/ \ VIA A t, , \ \\ Dn, TRACT \\ a - —�-- \ LOT n m e ETEAND \ _ �— _ _ \ Lorm \ �® s \\ \ EXISTING arT J \ \ AN1 _LOT 38 Lorb _�LOT_.t(IT a9� wr35_ _LOT 3i_ LOT VISA VILOT z ' ROFOSED / LOT $1 \ f FOREBAY EX ST NO f Lorm $ I ) t ERLND ND '.. 14 14 IT LOT 19 sP LOT15SiYa — LO]1]_.- M1$Ir 1i T - L' - A� J \ IT T777 E_J VVIV - MASER EA TwnJ ONNIEL Im OINM°aOE aMLNW 1Y VISIBLE D MEET aAOX o TOIN ASSET Oo.LT na na° IO} TicTc B+B IB°9E I.+r 010 WEI ONE w 1 1 1.19 aV "1 11.6 On a) 19 2 2 aK V9 "1 EA 3 3 LLOR 0.59 a)A 0.♦ IB A8 e LI D� 0.E l69 I)9 13 11 s OM D.n ME a) 12 ee on EVIL =4 21M 22 S) ) ail no 0.I5 153 ONE 03 TO e NORTH so 1m IBBhEI IN FEET ) LEGEND: m01CBBamaeEx[n PNxeeo Ee17 CCxT0.w 91 �FRUwIpM � —J95}— moFcam cLaleaRTa — _ VIX oma wN Q R9NArrW �--► BnNI.VC V9N1/BEL FREER W LARGE w W wi,AveaAs�eoDNwnY _ _ _ _ _ PADroeEDiwuEa2cnoN '—� ttVMoxaw NOTES. i HAVE_TAKET NRERYIN-0EV FROU THETSPEowra000 1ODARFONAR'EDI REEAD°FEAET:DONno i EMODEEn Nn CANER TO FIVE NED N�wEMERr2e m 3FORASILENCE ONADRIVING ORNAT�iON `IX i ESSEXTOTHE FLOLP%MEXHINT FOR CN98.fCTCx1 LOv.TKKN. WE ROOD ONS SWALE SECTIONS YN. of (FELT e� 4 �--ML°0 FT) SWALE SUMMARY TABLE SWALE ID MIND 1 MIN TW MIN BW 1 Di 1 5z LDD I low i z FOR DRAINAGE REVIEW ONLY ` NOT FOR CONSTRUCTION I- '. - cAMDmmnorinarwxcExrely ' nFN IB CWnxsbelOw. ll ISERESSE NET dig IANNER RAT ARM AR Ei IN As THE VNIVAING X City of Fort Collins. Colorado UTILITY PLAN APPROVAL APFPOV OFF MINse 0.1e cloom BY: Ilsier 1 Ream lm USENT,CHO Dlb IXFD 9Y: m1<� 0 nyf y dos PELY.E9 lad CHEdED Br: � 0.M ENEIXED BY Zc� a L3J Iz = W �Z a o" Zw 9# A-"eIP m 2 x W /w V Q Z