HomeMy WebLinkAboutDrainage Reports - 08/02/2012ty of Ft Collins v Plans
July 24, 2012
Mr. Glen Schlueter
Fort Collins Utilities — Stormwater
700 Wood Street
Fort Collins
RE: 1801 S. College Ave. Renovation Drainage Memo
JVA PN: 1952c
Dear Glen:
JVA, Incorporated
25 Old Town Square
Suite 200
Fort Collins, CO 80524
Ph: 970.225.9099
Fax: 970.225.6923
Toll Free: 877.444.1951
Web site:
www.jvajva.com
E-mail:
info@jjvajva.com
This letter is prepared to summarize the changes in impervious area and the stormwater quality
improvements associated with the site improvements for the renovation of the facility at 1801 S.
College Ave.
Proiect Description
1801 S. College Ave. is located at the southwest comer of Stuart Street and South College Avenue
and was previously occupied by a Maytag appliance retail store and a granite shop. The property has
been recently purchased and is proposed to be renovated to be mixed use commercial with a
combination of retail and restaurant occupancies. In general, as part of this renovation project, the
proposed site improvements will consist of modifications to the east and west parking areas, grading
modifications to accommodate a recessed sitting plaza adjacent to the west side of the building, a
potential sitting plaza space north of the existing building, incorporation of ramps and stairs along
the west side of the existing building for access to the lower and upper levels of the building, and
incorporation of additional landscape and stormwater quality areas.
Existing Drainage Patterns
The proposed drainage patterns are to remain similar to current patterns. Currently, all of the
western property drains to three inlets within the parking and service/loading area. See Figure 1
attached. The existing storm drain piping and inlets draining this site were recently improved with
the Choice Center project and are proposed to be utilized with these improvements. An existing 42"
reinforced concrete pipe (RCP) storm drain crosses the site, draining north to south. An existing 48"
RCP storm drain exits the site from the existing southern manhole and ultimately daylights into
Spring Creek. Two existing 18" RCP pipes connect to the 42" storm drain line, draining the two
area inlets adjacent to the west side of the building. The amount of runoff going to the two inlets
will be reduced with the modifications for the recessed plaza area. Due to the close proximity of
these inlets to the lower level of the building, Tideflex Checkmate check valves are being proposed
to be installed in these two inlets to reduce the chance of a storm event surcharging these inlets. An
existing inlet and a 14"x23" HERCP (horizontal elliptical) storm drain connects to the 42"storm
drain line, currently draining the remaining western parking lot. This inlet will remain and will be
utilized for the storm drain connection for the porous landscape detention area along the western
BOULDER I FORT COLLINS I WINTER PARK
1801 S. College Ave. Renovation
7/24/2012
2 of 3
property line. See Figure 2 attached. The existing manhole rims and inlet grates will need to be
adjusted to the proposed final grades.
The east parking area currently drains north to Stuart Street and south to College Avenue. Some
grading modifications are needed to improve accessibility from Stuart Street to the front of the
building. This slightly increases the area draining to Stuart Street, while reducing the area draining
to College Ave. The drainage is currently, and is proposed to be conveyed offsite via surface flows
and ultimately to Spring Creek.
Impervious Areas
The weighted historic and developed percent impervious was calculated based on the current City of
Fort Collins Stormwater Criteria Manual and the Urban Storm Drainage Criteria Manual. The
weighted percent impervious and composite runoff coefficient calculations, along with the rational
calculations are attached for reference. The existing site has an overall percent impervious of 90.6%,
and the proposed improvements will slightly decrease the percent impervious to 86.3%. The
decrease in impervious area is due to the increase in proposed landscape and the incorporation of
water quality areas.
Water Ouality Improvements
The water quality improvements will be achieved within the proposed landscape areas. Due to the
limited area within the east parking lot and the existing drainage patterns, site runoff is not able to be
directed to landscape areas. It should be noted that the amount of overall impervious area has
decreased by approximately 10% with an increased landscape area along the east side of the
property.
The west parking area will utilize a porous landscape detention (PLD) area, located along the west
property edge, for water quality improvements. The curb and gutter along the west edge of the park
area will have l' curb cuts at every parking stripe (every 8.5' to 9') and will drain into the PLD. The
PLD will have 18" of growing media to promote and maintain plantings. Below the growing media,
a perforated pipe, with a minimum of 6" of drainage filter gravel over the pipe, will convey
infiltrated runoff from drainage basin Al to the area drain located within the PLD area. The area
drain then conveys runoff to the existing inlet within the parking lot. To improve the effectiveness of
the PLD, the existing inlet and surrounding grades within the parking lot have been slightly raised to
direct flows around the inlet to the PLD. In the event that the area drain within the PLD becomes
clogged, the inlet in the parking lot would act as a secondary outlet. The outlet pipe from the PLD
area drain is sized at 12" with a full flow capacity of 3.27 cfs which is greater than the 100 year flow
rate from drainage basin Al of 1.68 cfs. See calculations attached. Due to the proximity of the PLD
to the retaining wall on the Choice Center site, it is proposed that an impervious membrane be
installed to limit water infiltrating against the foundation of the wall.
The roof drainage will be conveyed to landscape areas prior to entering the existing storm drain.
There are two roof drain locations, one along the north side of the existing building, and one in the
southwest corner of the building. The north roof drain will daylight to the landscape area along the
BOULDER I FORT COLLINS I WINTER PARK
1801 S. College Ave. Renovation
7/24/2012
3 of 3
north side of the building. The runoff will be conveyed across the landscape area to a sidewalk
chase that drains to Stuart Street. The runoff will continue south to the existing inlet on the south
side of Stuart and ultimately to Spring Creek.
The southwest roof drain will daylight into a landscape area surrounding the site's southernmost
existing storm manhole. The runoff will be conveyed across the landscape area and is proposed to
drain into this existing manhole. The manhole cover is proposed to be replaced with beehive grate.
All roof drains that are conveyed to the landscape areas will have a 5' long splash block directing
stormwater away from the building foundation.
Erosion and Sediment Control
During construction there will be temporary erosion and sediment control practices used to limit soil
erosion. These temporary erosion control devices include a vehicle tracking control/construction
entrance, a concrete washout area, inlet protection around all storm sewer inlets, curb rock socks
along Stuart Street, and sediment control logs along the boundary of the site. Additional details have
been provided on the plans including the Stormwater Management Plan (SWMP).
Based on the included information, the proposed improvements and adjusted impervious areas, the
overall imperviousness of the site has decreased by approximately 4.3% compared to existing
conditions. Minor topographic changes are proposed within the floodplain, but are considered to
have no adverse impacts due to minor allowed disturbance within the assumed ineffective flow area.
Please feel free to contact JVA to discuss any questions you may have.
Sincerely,
JVA, INCORPORATED
Charles R. Hager, IV, P.E.
Vice President
Enclosure:
Figure 1 - Historic Drainage Map
Figure 2 - Developed Drainage Map
Composite Runoff Coefficient Calculations
Drainage Basin Summary Table
PLD Sizing Calculations
CC: Vaught Frye Larson architects
Ripley Design, Inc.
Imago Enterprises
Lester Kaplan
DO REgi;>"/
••....•#
� R HgC`9�0
37146 'J3 e
7/24/12 r
BOULDER I FORT COLLINS I WINTER PARK
I 1
` —
� T o0
E)(IST 42m RCP SD
I �
EXIST 14"x 23" EXIST SD MH
'I HERCP SD
EXIST SD 1
AREA INLET
EXIST 42" RCP SD
� 09 0.17 1
1
� � I
I
EXIST SD MH
i 1 �
IEXIST 48" RCP SD
Liu I I I
�TUAR� TREET
:<' �..�
01 0.07
EXIST 18" RCP SID o.7 02 O
i
� o
2 EXIST SID
AREA INLET
I z
� Z
m
0 1801 0
"� � o
S. COLLEGE AVE. o� all o
1 (EXISTING BUILDING) G
C5
EXIST 18" RCP SD
100-YR FLOODPLAIN G ,
EXIST SD
AREA INLET " ml
/ - HIKErpf ..y�
��
6 CIAYI
n .. Wx..H
i
OOrwme J rsa}tlnn `I .
J 11 ! E {I(1 ' 1' wCE Wf!'AiLL � 1?hI,IIC CAP J
e_1^ri. GONCRCIE .y(mlmI cVMKING i53194i
WIH,'oul f"cllV l
LEGEND
PROPOSED INDEX CONTOUR M PROPOSED DRAINAGE BASIN BOUNDARY (MAJOR BASIN)
PROPOSED DRAINAGE BASIN BOUNDARY (SUB BASIN)
PROPOSED INTERMEDIATE CONTOUR DIRECTION OF FLOW (HISTORIC)
EXIST INDEX CONTOUR 1.0%i DIRECTION OF FLOW AND SLOPE (DEVELOPED)
�1 EXIST INTERMEDIATE CONTOUR BASIN DESIGN POINT
q A = DEVELOPED BASIN DESIGNATION
5 1.0 DRAINAGE BASIN IDENTIFICATION BUBBLE .5 = 100-YR RUNOFF COEFFICIENT
1.0 = AREA ACRES
20 0 20 40
SCALE IN FEET
SUMMARY
RUNOFF TABLE
I
BASIN
DESIGN
AREA
5 YR
100 YR
POINT
(ACRES)
RUNOFF
PEAK
(CFS)
(CFS)
H1
1
0.17
0.55
1.49
H2
2
028
0.72
2.06
H3
3
0.07
0.18
0.50
H4
4
0.11
0.32
0.87
S-.rE ND
FIG-1
a
0
Lm-m-mH•qm-Q�H•Ht
�7Y�
V
Al
Ob 0
1 18" SD INLET —
EXIST 14"x 23"
HERCP SD
LROUS LANDSCAPE
TENTION AREA
GNG WALL
�T1, r14 0STREET
-
\ 7 C4N-
-�� -- —� R4 --
Z 1 X-�\tw
EXIST 42' RCP SD
\ -EXIST SD MH -
V \ C
EXIST SD \
AREA INLET
EXIST 42" RCP SD
oor
EXIST SD MH
REPLACE EXIST
COVER WITH
BEEHIVE GRATE
IEXIST 48" RCP SD
LEGEND
PROPOSED INDEX CONTOUR
PROPOSED INTERMEDIATE CONTOUR
EXIST INDEX CONTOUR
EXIST INTERMEDIATE CONTOUR
PUST,C GP J
LLt, R
a F •I.tUiING
'M�N� IFlM t:Vl'l
SIDEWALK CHASE
ROOF DRAIN A2
EXIST 18" RCP SD I 09102D
EXIST SD AREA INLET
INSTALL TIDEFLEX
CHECKMATE CHECK I
VALVE IN INLET
12"x 12" AREA INLET
I
- PROPOSED RETAINING WALL
100-YR FLOODPLAIN
EXIST 18" RCP SD
EXIST SD AREA INLET
INSTALL TIDEFLEX
CHECKMATE CHECK
VALVE IN INLET
ROOF DRAIN /
FOiI U.Vifl OIIFI.'.N (INIMV' J
00
11
A3 i 1
OB 0.11 1
1 \
1cn
88 1
I
I
I
88 I
I
C6 I 11
A4 _ I
0.7 0.09
11
I
II I
I 4 11
11
. I
I
0o SIDEWALK CHASE 11
1
`��1ygi 0 'NIUI J
{{I11I ! "JIOE N^lflll p:l 1.
�nCP2TC �� "INI(=PMIIIN(f
A.",.. i:f IIIt YC LL 'CN !./. 4Y JI1lEN (INIV'
PROPOSED DRAINAGE BASIN BOUNDARY (MAJOR BASIN)
— PROPOSED DRAINAGE BASIN BOUNDARY (SUB BASIN)
DIRECTION OF FLOW (HISTORIC)
—� DIRECTION OF FLOW AND SLOPE (DEVELOPED)
�1 BASIN DESIGN POINT
A A = DEVELOPED BASIN DESIGNATION
5 1.0 DRAINAGE BASIN IDENTIFICATION BUBBLE .5 = 100-YR RUNOFF COEFFICIENT
1.0 = AREA ACRES
�= Olklj INI
SCALE IN FEET
SUMMARY
RUNOFF TABLE
E
BASIN
DESIGN
AREA
5 YR
100 YR
POINT
(ACRES)
RUNOFF
PEAK
(CFS)
(CFS)
Al
1
022
0.60
1.68
A2
2
0.20
0.55
1.54
A3
1 3
1 0.11
023
0.70
A4
1 4
1 0.09
022
0.63
a
w
U)
Q
d
d Q
z 2
w
z
z
w o
or Cl
w Lu
CD o_
w p
J J
o ">
U
0
Fwt-T NO
FIG-2
1801 S. College Ave.
PROPOSED COMPOSITE C AND IMPERVIOUS AREA CALCULATION
Design Engineer.
D.Douvas
Design Finn:
JVA, Inc.
Project Number.
1952c
Date:
February 29, 2012
DESIGN CRITERIA:
JVA, Incorporated
25 Old Town Sq, Suite 200
Fort Collins, CO 80524
Ph: 970.225.9099
Fax: 970.225.6923
Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised April 2008)
City of Fort Collins Stormwater Criteria Manual (Ordinance No. 174, 2011)
BASINS:
% Impervious values from Table RO-3 and C Values obtained from Table RO-5 in the Urban Storm Drainage Criteria Manual
for Hydrologic Soil Classification B
Land Use
% Impervious
C VALUE
C2
Cs
C1w
Roofs
90.0%
0.71
0.73
0.81
Parks
5.0%
0."
0.10
0.38
Streets
100.0%
0.89
0.90
0.96
Drives & Walks
90.0%
0.71
0.73
0.81
Lawns
0.0%
0.02
0.08
0.35
Sub -basin
Designation
At�w
(acres)
Air
(acres)
Aqft
(acres)
APe ed
(acres)
A,.aa
(acres)
Aa.
(acres)
Weighted %
Impervious
COMPOSITE ,
C2
Cs
C7oo
H1
0.17
0.00
0.01
0.16
0.00
0.00
96.8%
0.82
0.84
0.90
H2
O.28
0.14
0.02
0.10
0.01
0.00
96.3%
0.65
0.67
0.76
H3
0.07
0.00
0.01
0.04
0.02
0.00
98.4%
0.68
0.70
0.79
H4
0.11
0.00
0.01
0.08
0.02
0.00
93.4%
0.76
0.78
0.85
Historic overall
0.62
0.14
0.04
0.39
0.04
0.00
90.6%
0.72
0.74
0.82
Al
0.22
0.00
1 0.02
1 0.18
1 0.01
1 0.00
1 89.6%
1 0.70
1 0.72
1 0.80
A2
0.20
0.14
10.00
0.00
0.05
0.00
90.3%
0.71
0.73
0.81
A3
0.11
0.00
0.02
0.05
0.04
0.00
75.3X
0.51
0.54
0.68
A4
0.09
0.00
1 0.01
1 0.06
0.02
1 0.00
1 93.3%
1 0.61
0.63
0.73
1
Proposed Overdl
0.61
0.14
0.06
1 0.29
0.12
1 0.00
86.3%
1 0.65
0.67
0.77
c Proposed Rabonal.)dsx - COMPOSITE C Page 1 of 1 JVA, Inc.
1801 S. College Ave.
PROPOSED DRAINAGE SUMMARY
Design Engineer. D.Douvas
Design Finn: JVA, Inc.
Project Number. 1952c
Date: February 29, 2012
DRAINAGE BASIN SUMMARY TABLE
JVA, Incorporated
25 Old Town Sq, Suite 200
Fort Collins, CO 80524
Ph: 970.225.9099
Fax: 970.225.6923
DESIGN
POINT
TRIBUTARY
SUB -BASIN
AREA
(acres)
Cx
CS
C1os
tx
(min)
02
(cfs)
45
(cfs)
4100
(cfs)
DRAINAGE REMARKS
1
H1
0.17
0.82
0.84
0.90
5.00
0.39
0.55
1.49
2
H2
O.28
0.65
0.67
0.76
5.00
0.50
0.72
2.06
3
H3
0.07
0.68
0.70
0.79
5.00
0.12
0.18
0.50
4
H4
0.11
0.76
0.78
0.85
5.00
0.22
0.32
0.87
Historic Overall
0.62
0.72
0.74
0.82
1.24
1.77
4.92
1
At
0.22
0.70
0.72
0.80
5.20
0.42
0.60
1.68
2
A2
0.20
0.71
0.73
0.81
5.00
0.39
0.55
1.54
3
A3
0.11
0.51
0.54
0.66
5.00
0.15
0.23
1 0.70
4
A4
0.09
0.61
0.63
0.73
5.65
0.15
0.22
1 0.63
Proposed Overall
0.61
0.65
0.67
0.77
1.11
1.59
1 4.54
c Proposed Rational.xisx - Summary Page 1 of 1 JVA, Inc.
Worksheet
Worksheet for Circular Channel
Project Description
Worksheet SD sizing for west porus landscape detention
Flow Element Circular Channel .
Method Manning's Formula
Solve For Full Flow Capacity
Input Data
Mannings Coefficient 0.010
Channel Slope 0.005000 ft/ft
Diameter 12.0 in
Results
Depth
12.0 in
Discharge
3.27 cfs .4
Flow Area
0.8 ft'
Wetted Perimeter
3.14 ft
Top Width
0.00 ft
Critical Depth
0.77 ft
Percent Full
100.0 %
Critical Slope
0.005589 ft/ft
Velocity
4.17 We
Velocity Head
0.27 ft
Specific Energy
15.2 in
Froude Number
0.00
Maximum Discharge
3.52 cfs
Discharge Full
3.27 cfs
Slope Full
0.005000 ft/ft
Flow Type
N/A
Drainage Basin Al has a
100-year flow rate of 1.68 cfs
3.27 cfs > 1.68 cfs O.K.
Project Engineer: Kevin Tone
untitled.fm2 JVA, Inc FlowMaster v7.0 [7.00051
03/01/12 04:13:41 PM m Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA +1-203-755-1666 Page 1 of 1
Design Procedure Form: Rain Garden (RG)
Sheet 1 of 2
Designer: D. Hamer
Company:
JVA Consulting Engineers
Date:
March 28, 2012
Project:
1952c 1801 S. Colleg Ave.
Location:
1801 S. Colleg Ave., Fort Collins, CO
1 Basin Storage Volume
A) Effective Imperviousness of Tributary Area, I,
I, =
89.6 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = I.M 00)
1 =
0.896
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time
WQCV =
0.32 watershed inches
(WQCV= 0.8' (0.91• i3- 1.19' i'+ 0.78' 1)
D) Contributing Watershed Area (including rain garden area)
Area =
9.583 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume
Vwocv =
cu ft
Vol = (WQCV / 12)' Area
F) For Watersheds Outside of the Denver Region, Depth of
da =
0.82 in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,
Vwocv OTHER =
485.0 cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume
VWOCV USER =
OU It
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
Total surface area
A)WQCV Depth (12-inch maximum)
Owocv=
0 in
provided is greater than
B) Rain Garden Side Slopes (Z = 4 min., hor¢. dirt per unit vertical)
Z =
0.00 ft/ ft
required
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area
A,,=
323 sq ft
Due to limited grade, no
additional storage Volume
D) Actual Flat Surface Area
Aa=
424 sq It
has been achieved above
E) Area at Design Depth (Top Surface Area)
AT. =
424 sq ft
the growing media
F) Rain Garden Total Volume
VT=
0 cu ft
(VT=((Arm+Aa )/2)'Depth)
3. Growing Media
Choose One
Q 18" Rain Garden Growing Media
O Other (Explain):
4. Underdrain System
A) Are underdrains provided?
Choose One _7
(9) YES
O NO
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage
y=
0.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours
V0112 =
N/A cu ft
III) Orifice Diameter, 3/8" Minimum
Do =
N/A in
1952c PLD System - UD-BMP_v3_Ot.xisx, RG 3/2812012, 11:51 AM
Design Procedure Form: Rain Garden (RG)
Sheet 2 of 2
Designer: D. Hamer
Company: JVA Consulting Engineers
Date: March 28, 2012
Project: 1952c 1801 S. Colleg Ave.
Location: 1901 S. Colleg Ave., Fort Collins, CO
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
Choose One
* YES
A) Is an impermeable liner provided due to proximity
ONO
of structures or groundwater contamination?
PROVIDE A 30 MIL (MIN) PVC LINER WITH COOT CLASS B
GEOTEXTILE ABOVE IT. USE THE SAME GEOTE7(TILE BELOW THE
LINER IF THE SUBGRADE IS ANGULAR
6. Inlet / Outlet Control
Choose One
* Sheet Flow- No Energy Dissipation Required
A) Inlet Control
0 Concentrated Flow- Energy Olssipabon Provided
Choose One
7. Vegetation
O Seed (Plan for frequent weed control)
* PlantIngs
10
Sand Grown or Other High Infiltration Sod
S. Irrigation
Choose One
O YES
A) Will the rain garden be irigated?
O NO
Notes:
1952c PLD System - UD-BMP_v3_Ot.xisx, RG 3128/2012, 11,51 AM