Loading...
HomeMy WebLinkAboutDrainage Reports - 06/05/20081 1 1 1 1 1 1 1 1 1 PROPERTY OF Cky of Ft COMM � FORT COLLINS �� AWovW 6y . FINAL DRAINAGE & EROSION CONTROL STUDY FOR NEW BELGIUM BREWERY FOURTH FILING, LOT 2 1 1 t 1 1 1 1 FINAL DRAINAGE & EROSION CONTROL STUDY FOR NEW BELGIUM BREWERY FOURTH FILING, LOT 2 Prepared for: Solix Biofuels 430 North College Avenue Fort Collins, CO 80524 Prepared by: North Star Design, Inc. 700 Automation Drive, Unit I Windsor, Colorado 80550 (970) 686-6939 April 7, 2008 Job Number 110-15 i North Star `.design, inc. April 7, 2008 rBasil Hamdan City of Fort Collins Stormwater ' 700 Wood Street Fort Collins, CO 80522-0580 ' RE: Final Drainage & Erosion Control Study for . New Belgium Brewery, Fourth Filing, Lot 2 (Solix Biofuels) Dear Basil, I am pleased to submit for your review and approval, Final Drainage & Erosion Control Study for New Belgium Brewery,. Fourth Filing, Lot 2 (Solix Biofuels). I appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. III IIII////// Sincerely �� �� O� RE... Patri is Kroet President 1 ii ' 700 Automation Drive, Unit I Windsor, Colorado 80550 970-686-6939 Phone 0 970-686-1 1 88 Fax TABLE OF CONTENTS ' TABLE OF CONTENTS............................................................................................................... in 1. GENERAL LOCATION AND DESCRIPTION ' 1.1 Location and Description of Property......................................................................1 1.2 Purpose of Report ....................................................................................................1 2. DRAINAGE BASINS AND SUB -BASINS 2.1 Major Basin Description..........................................................................................1 ' 3. 2.2 Sub -Basin Description.............................................................................................2 DRAINAGE DESIGN CRITERIA 3.1 Regulations..............................................................................................................2 3.2 Development Criteria Reference and Constraints....................................................2 3.3 Hydrologic Criteria..................................................................................................3 3.4 Hydraulic Criteria....................................................................................................3 4. DRAINAGE FACILITY DESIGN 4.1 General Concept......................................................................................................3 4.2 Specific Flow Routing.............................................................................................4 4.3 Drainage Summary ...................................................................................................5 5. EROSION CONTROL & WATER QUALITY 5.1 General Concept......................................................................................................5 5.2 Specific Details...................................................................................................:....6 ' 6. CONCLUSIONS 6.1 Compliance with Standards....................................................................................7 ' 7. 6.2 Drainage Concept.....................................................................................................7 REFERENCES....................................................................................................................8 APPENDICES A Vicinity Map ' B Hydrologic Computations C Retention Pond Infiltration Basin Calculations ' D Excerpts from Previous Reports 1 7 2 1 GENERAL LOCATION AND DESCRIPTION 1.1 Location and Description of Property The subject property is located in east of downtown Fort Collins on the north side of Buckingham Street, east of Linden Street and west of Lemay Avenue. New Belgium Brewery, Fourth Filing, Lot 2 contains approximately 14.6 acres and the proposed site will be located on approximately 3 acres of this lot. The entire property is located in the Northeast Quarter of Section 12, Township 7 North, Range 69 West of the Sixth Principal Meridian, in the City of Fort Collins, Larimer County, Colorado. Lot 2 currently houses the New Belgium Brewery Waster Water Treatment Plant on the northeast portion of the lot with an existing retention pond on the southeast portion of the lot. The Solix site is being proposed on the northwest portion of the lot and a stockpile of lime waste material exists on the southwest portion of the lot. The stockpile has been tested and the material has been determined to be benign. A portion of the Solix site drains to the east and into the existing retention pond and a portion of the site drains to the west into an existing low area. See the drainage plan in Appendix A for approximate contours indicating the slope of the site. 1.2 Purpose of Report The purpose of this report is to analyze the effect of the proposed improvements and to propose solutions to mitigate any adverse impacts to the existing site. DRAINAGE BASINS AND SUB -BASINS 2.1 Major Basin Description The proposed site area lies within the Cache La Poudre River Drainage Basin. The site is a portion of the area that was included in the Overall Development Plan Drainage Report for New Belgium Brewery by North Star Design, Inc. dated February 20, 2001. Drainage reports have been completed for the existing New Belgium Brewery area including the "Drainage and Erosion Control Report for New Belgium Brewery, Fort Collins, Colorado" by Water, Waste & Land, Inc. dated March 30, 1995, the "Final Drainage and Erosion Control Report for New Belgium Brewery First Filing" by JR Engineering, Ltd., I� ' dated December 23, 1997 and the "Final Drainage & Erosion Control Study for New Belgium Brewery Process water Facility" by North Star Design, Inc. dated July 30, 2001 as well as multiple updates to these reports. ' 2.2 Sub -basin Description The ODP area was divided into two basins and were delineated in the ODP drainage ' report as the West Basin and East Basin. The West Basin included the area that is currently developed and contains the existing New Belgium Brewery and the Packaging Hall as well as an undeveloped area. The majority of this basin drains to existing detention ponds. The East Basin included the remaining ODP area and contains the Process Water Treatment Plant and undeveloped area. The Solix site is located at the divide between the East and West Basins and therefore, a portion of the site drains east ' and a portion of the site drains west. f 3. DRAINAGE DESIGN CRITERIA 3.1 Regulations This report was prepared to meet or exceed the "City of Fort Collins Storm Drainage Design Criteria Manual" specifications. Where applicable, the criteria established in the "Urban Storm Drainage Criteria Manual" (UDFCD), 1984, developed by the Denver Regional Council of Governments, has been used. 3.2 Development Criteria Reference and Constraints The runoff from this site has been routed to conform to previous calculations completed with the Overall Development Plan for the New Belgium Brewery by North Star Design dated February 20, 2001. Retention for this site is provided on site as required in the ' above -mentioned report. This site is within the 500-year flood plain based on the FEMA maps but, because of recent changes in City criteria, no restrictions will be placed on this facility because of the 500-year flood plain. The site is not located in the 100-year flood plain. z 7 0 3.3 Hydrologic Criteria Runoff computations were prepared for the 10-year minor and 100-year major storm frequency utilizing the rational method. All hydrologic calculations associated with the basins are included in Appendix B of this report. Standard Form 8 (SF-8) provides time of concentration calculations for all sub - basins. Standard Form 9 (SF-9) provides a summary of the design flows for all Sub - basins and Design Points associated with this site. 3.4 Hydraulic Criteria All hydraulic calculations within this report have been prepared in accordance with the City of Fort Collins Drainage Criteria and are also included in Appendix B of this report. DRAINAGE FACILITY DESIGN 4.1 General Concept In general, the drainage design of the Solix facility site will be required to conform to the previously completed Overall Development Plan drainage study that governs the drainage design of this site. The drainage design will be designed to accommodate the Rainfall Intensity -Duration -Frequency curve data adopted by the City of Fort Collins on March 26, 1999. This project will also utilize the existing retention ponds created with the construction of the Process Water Treatment Plant and a proposed infiltration gallery to accommodate additional site runoff generated by the increased imperviousness. The Solix Facility will have minor impacts on the amount of runoff from the site. The tank area and emergency accesses will all be gravel, recycled asphalt or a material with similar low imperviousness. The site will also have a 5000 square foot building, a small asphalt parking lot and an asphalt drive. The remainder of the site will be landscaped or will be native existing landscaping. It is proposed to allow the undeveloped area to continue to drain as it has historically done to preserve the existing trees and maintain a natural feel to the area. 3 I L I hi J d In order to maintain a high level of water quality infiltrating into the ground an infiltration basin is being proposed in the southern portion of Basin 3. Basins 1 and 2 currently route stormwater to existing retention ponds and therefore infiltration basins are only being proposed for Basin 3. Improvements installed in this basin include a portion of the proposed building, the gravel turn -around, the asphalt driveway, asphalt parking area, the existing volleyball court and existing vegetation and landscaping. The infiltration basin has been designed using the New Jersey Stormwater Best Management Practices Manual, Chapter 9.5, dated February 2004 and the Urban Drainage Storm Drainage Criteria Manual, Vol 3, Best Management Practices, dated September, 1999 as guidelines for the design. For Basin 3 the 100-year storm event is being detained in the infiltration basin. It has been estimated by Earth Engineering Consultants (EEC) that the soils present in boring B-5 will have an infiltration rate in the range of 2 in/hour to 6 in/hour. It has been calculated that the infiltration basin will be completely drain the 100-year storm event in 12 hours. This calculation assumes no stormwater infiltration during the time the infiltration basin in filling and once full, the most conservative 'infiltration rate of 2 in/hour has been used. The infiltration basin has been designed to be a maximum of 2' deep. Calculations for the infiltration basin are included in Appendix C. A sand volleyball court exists within Basin 3. This existing volleyball court is constructed similar to the infiltration basin, therefore any runoff entering the sand volleyball court will have similar characteristics as the infiltration basin. The infiltration basin has adequate volume and capacity to accept, retain and infiltrate the 100-year storm but it is unlikely that the infiltration basin will ever utilized its entire volume. 4.2 Specific Flow Routing A summary of the drainage patterns within each basin is provided in the following paragraphs. Subbasin 1 contains the north portion of the site including the Process Water Treatment Plant (PWTP) and a small portion of the Solix tank area. The area and c-value for this basin did not change significantly with this development, therefore, no changes are proposed to the existing Retention Pond 1. Runoff from this basin is collected in a ditch along the south side of the access road and be conveyed east to Retention Pond 1. 4 the chemical storage building and the concrete parking area north of these buildings. This Basin will not be affected by the Solix development. Subbasin 2 contains the west portion of Lot 2 including west side of the PWTP, a ' majority of the Solix tank area and the lime stockpile. Runoff from this basin will be collected in a ditch along the west side of the treatment plant and be conveyed south to ' Retention Pond 2. The addition of the Solix development will increase the required retention volume from 0.88 acre feet to 1.09 acre feet. This additional volume will be accommodated by increasing the height of the berm along Buckingham Street by 0.30'. Subbasin 3 contains the western portion of the site including the building, the asphalt drive, the parking area, the west portion of the Solix tank area and a large portion of landscaped or undisturbed area. Runoff from this basin will be collected in the existing ' low area where an infiltration basin is proposed. Stormwater that enters the infiltration basin will naturally drain into the ground and will be conveyed away from the site within the groundwater network. Based on boring logs provided by EEC it was found that the groundwater is approximately 4.0' below the existing grade. The infiltration basin will be depressed into the ground 2.0' which will leave approximately 2.0' from the finished grade of the infiltration basin to the groundwater table. ' 4.3 Drainage Summary Retention ponds are being provided for this site in order to minimize the amount of flow ' leaving this site and to preserve existing trees. In the future, when downstream improvements are made to the storm drainage system, the retention ponds may be converted to detention facilities with release pipes. The drainage facilities located on this site will be maintained by the owners of the site. ' 5. EROSION CONTROL & WATER QUALITY ' 5.1 General Concept This site lies within the Moderate Rainfall and Wind Erodibility Zone per the City of Fort tCollins Zone Maps. The potential exists for silt movement from the site and into the ' 5 I 1 1 1 1 I 1 existing storm system during construction. Potential also exists for tracking of mud onto existing streets which could then wash into existing storm systems. . The proposed plan utilizes Best Management Practices to limit the amount of sediment that will leave the site. The plan is adequate to meet the intended purpose of erosion control. Refer to the Drainage & Erosion Control Plan provided in the back pocket for specific details. Permanent water quality on the site is provided by the existing retention ponds and the proposed infiltration area. Since the ponds will not have a release, the runoff from the site will collect in the ponds and allow sediment and contaminants to settle out of the water. In the future, when the retention ponds are converted to detention ponds, the ponds shall be sized with additional volume for water quality extended detention and a water quality outlet structure will be installed. 5.2 Specific Details To limit the amount of silt leaving the site, several erosion control measures shall be implemented during construction. Silt fence shall be placed around the area that will be disturbed and a vehicle tracking pad shall be installed at the entrance off Buckingham Street to control the mud being tracked onto the existing pavement. During overlot grading, disturbed areas are to be kept in a roughened condition and watered to reduce wind erosion. G-I 11 71 6. CONCLUSIONS 6.1 Compliance with Standards ' All computations that have been completed within this report are in compliance with the Overall Drainage Concept for the Overall Development Plan for New Belgium Brewery, ' the City of Fort Collins Erosion Control Reference Manual for Construction Sites and the Storm Drainage Design Criteria Manual. The site is within the 500 year floodplain but no additional requirements are imposed because of this. 6.2 Drainage Concept ' The proposed drainage concepts presented in this report and on the construction plans adequately provide for the transmission of developed on -site runoff to the existing retention ponds or to the proposed infiltration gallery. The onsite drainage facilities (drain basins, pipes) will provide for the 10- year and the 100- year developed flows from Basins 1, lA and 2 to reach the existing retention facilities and Basin 3 to reach the proposed infiltration gallery. ' If, at the time of construction, groundwater is encountered, a Colorado Department of ' Health Construction Dewatering Permit would be required. 1 7 7. REFERENCES 1. City of Fort Collins, "Storm Drainage Criteria Manual", (SDCM), dated March, 1986. 2. Urban Drainage and Flood Control District, "Urban Storm Drainage Criteria Manual", Volumes 1 and 2, dated June, 2001, and Volume 3 dated September, 1999. 3. Final Report for Hydrologic Model Update for the Foothills Basin Master Drainage Plan by Anderson Consulting, Inc. dated July 15, 1999. 4. "Overall Drainage Concept for the Overall Development Plan for New Belgium Brewery", dated February 20, 2001 by North Star Design, Inc. 5. "Final Drainage & Erosion Control Study for New Belgium Brewery Process Water Facility" by North Star Design, Inc. dated July 30, 2001 6. "New Jersey Stormwater Best Management Practices Manual", chapter 9.5, Standard or infiltration basins, dated February 2004. 8 11 n H E 1 i� J 7 1� APPENDIX A VICINITY MAP A PROJECT SITE SITE as z palz aommoll- ME --MU < VICINITY �MAP. FORT COLUMS D0.NTG." AIRPARK STATE HIGHWAY 14 I .1 I u 1i L� 1 RETENTION POND SUMMARY DRAINAGE SUMMARY TABLE --------- - ' wrKPry POND I POND 2 DETENTION REQUIRED 0.51 AC. FT. 0.55 AC. FT. RETENTION REQ(JtRED 1.02 AC,.FT. 1.10 AC.Fr. 100 YR HMEL 4947.54 4948.80 MAX RELEASE RATE 0 CFS 0 CFS P, AN AREA RHEA Go 1;100 Ic (Ill) (MIN) rC (100) p (10) Q (100) • 1 4, 1 0.211 0.56 15.0 1 15.0 i 9.7 ;A IA U.Y9 LLti9 0.87 8.2 5.2 U.H1 2.2 2 2 5.55 0.26 0.33 14.1 1 14.1 1 4.77 1 12.1 5 .5 5.26 0.28 0.35 9.8 1 4.8 1 564 11 14.4 Qtx] lather - - Pnwow, - _ will rW aY o"Awler Mt'PIY nyIME lo-m mrar r]xTr,rtxr �AaYEW r IAIE e AUPE apEA M a(TES W E1lrwG r r;l)Nr aoY mlEcrlw I TOP OF BERM \.J PPGIFDQn' rn.lmua: ELEVA nON O® o s"wXnw EelaAxcE ...11�-- rPrnDxo s r;lylrrv)at LO' IiPILLWAY ELEVA OON Off\ We11tE-...-... -...- woPO4D :' CONSK+F PAN PPaPas[D .AUTF PRE AVE Is• I O ® w1Er momcilm = _ _ _ = Elaalwc) mAw I:IP( TYPE L BURIED con I WAY CROSS SECTION RIPRAP O xaM!h`T MAP .«wrxD Bases tYalxowr NT3 P f _ l UIIRN 89pCE GE .. _ ... bier_ �y - = ,% ­11 I I! I .• .. ... ... � I I - ... me4ms_ ___ _ _ _ 1 � yam- ' ' -J � - � . I II -.� -../.- _/.- - _.. weew wee, Ir' - ♦ : s �_ .... .� i _ _ -77 BAD ' �-h \.. � - Tom wi� ' \ ... - O -o-- .. , tj, I I exes aD1E1BIT10M I - L"')•29 .�� I\;o�1efD 1 x �� / I ,!. •L7 _Y'-+� mat 7�1{1�'�.' - . .. r`-I- - - [ _ 11 YalAE-t Ot I awe ._.. ,- w �: I rV�'"v'�`�«u r� ,uAll F, II - -STANDARD El sweet the m • �Y. I 5 - - - , ,.. l ` n - r, k' �1 r - ... •R tl 1 I 1 r. the roman r .- Ya6EY POIREN f. )I '.. r ! •- ', D 1 1 1' I I ` .1 m, .,a. ti •�W� v y i ii1�41 T t I X i -^� r �■t \ -_. _ .�r� ---_ �*-r �` is r. I[ 1 • ;Q ! NBB NIMTP IriT I h I : I I I 1 �I i here ewvel, (lini weal aoo,a�Pr le lima ;1'I am t dean ft ♦. Atmaae X E]651NG T a: 114. oawArt YT (p awrm ew a '.'I ! . I ' . / • \ `� 1 �- X v6EMO+r yF :II, I�n•�P..d eia•, :eai ,• x \ _ e \! II.: L �,al 'p III 'I i I 1. wet y .aq 1 , Mwt ID ti 6, w woe .a, �e A::YU !I.'. al. 6. a , a • \ • \ •'� I 1'' : I Dwmana:l w F. i ��• `�. � \ j •1���., f I ,.mod . .ae .r^ T'I !I IIII ormma, .« \ :I r 1 I r. a Ear 1 r III - - �\ ' T' I� 'I -III 1 B n a „it II I ithereimeat \ I l i �,•I O d 1 i (I I I n r:m ,aroa + /--1'j --- -1 „•1 i !. s 1 ! .I JT !1 f ill II III W The aeead awash, 4 3.26 0.25 T 1TZ I • I 0n� Id tl 11 I, RE565m EKM a ! 1 I 11 �DELeIFA11a1 A I '� 1 I ��5 r rrrrn.^+ I: :T III l 11. GwWmY. mat ►FUilA90E1' • l 1'. 'rtJ 1 I I 1 i 1 ! I : (swat, er le �: •2 I 1 14 -t1,. tl itl 1 i I i I ! I� III t2 )ma „am. 1 { i I 8118M . I \ , '.� I \ •I• I !. 1 I T N:i^- r:,, boat bobi • e i D *5 5.5 i 0.26 i I Aewad Ian (HD 3 I .._ �" I 1 tDD,R :. ;`'.•,,R�'I I� ! u. City osra d034'ACFT. � I \ y,. I . -- r �. -� -.. LI,.x ee♦n]0 ../ , ` 1 t :t 1 ) III mow 1M ebdb I:mr .e to lip e•000ttde:nw•n uo IFI' Imad .eWnrr Z • �lI DE]1FwlIM 1 I `\, , angel. n /F Eutnr) lAy, �' i �nru<lea w 1 f,il. AYw, wY i :.w aw w. rwa wrOWAE!arl I I I -erma welrve \'.. I l l ae mr1Y a 111n awaw to E708TM0 rt7BEiIloN 1!dD!"% I we ewe P � . - aasn+c wuAE-aee 7cFr. \- ._ - _- r// I rd .. I OOS,.IG.N.E1,..9t8iD I A Bad. -tea 1 r B a, to r -/ 9 xr' '(` .I'.I _ _ - ` I ..% 4Mn0o I , ✓ ....- 4 C.D. Other aarp o �hw I R .E X '1'` ✓ - 16. wet ._-.,Lle+ 'F•a: rv�i'" ,_+Y .. '� _ I. lL nrvg ry or, =- '------------ r•..-. ✓ metro �. ..- w _ _ `'s .. 9 �i '-: \ cam, w!. „� r we" .. . bn.eo I k _�_�__ �" %I __ - _ _____-- _ _ __- _ _____ _-__ i i n I &1CJONONAY STREET ... � � -+ CALL VT POND 2 SPILLWAY ELEVA❑ON 4948.80 TpP OF BERM ELEVATION 4449.80 RIPRAP DIMENSIONS IS Wal6'La1.5'0 _2•�y�,-,.. x - - - -v.r= - - �.r.- - _ _ _ - _ --`- _ _ _ _ _.------ RAISE _ _ - _ _ _ ,-�- ,~S �-: �.,. -.-a:x..-.... CENTEI TDP OF "� 1.800 BaselW460 • •.RECONSTROCT 1 , I PE nAE m .. n I saLLWAY PER ME MTUL I vW uE cg 7 50 _ ].5 0 -A) 1p0 t$� O p�j 4 eD m I r. APPENDIX B HYDROLOGIC COMPUTATIONS 1 1 1 1 1 1 F 1 I � � m R LU w - 7j E§ Rq ° 7aj � 0w S § 0 § I �, §¥\ 800� } CL E co §-7 )Eko\)666 ��0 ° bu I � § o § co c { F- -e \ -\ �� 2 � \\�cu f � T~` CL \ z-E7 ])n \\E » m Cc / ]R= .d0 0 <a)-� §e=.. EE §§§ u/\W S/Ej )«) ®0 )§; J; § £ z®& ;;; ;; S )0 � w , /»# (»$ \$ $ §!e § }} \ \$# wk} 0 0: 0 » ° ° _ t » <0 §±F &&° »r » \*# < _ „ �, }<{ } #5R ® [*k \�\ (( k #!J §§§ \§ § )< §\ m@ / co E e a e\«z 2 0.ca 2 co .-L 0 \ (§/G cu \ \ \ \\\/ # - / «(±£ 2E0.E3 E { - \eoeck fj ) - { §o } ro ) Ll 3 } I C-1 I I } O 7- U O ce Z Lu F U v Z O 3 v U. v O o uj a` F" 3 L w O b0 � O W O N O n U CQ z 0 zz°O¢ W 0 � h Y Q W O N O 7 m J IA CO O lf) < N r z � E LL Z Om C V E Q m ti O.. o m oM o Z w uoi u 7 II � N m aG N of W V # m m m M A 3 v o m v 07 m o LL W O< T O CI m Z d O O O z x U rn o m o 0 0 0 c 0 O Q o 0 c o 0 0 W k m o r 0 r 0 y C O C O 6 6 O D Q _ N v W m N b � L omp am0 W m Q 1¢L J Z m.-r rin A C N r IG IA b � " E Poo 0 0 0 N O N N 05 W � mom N N a W U 0 0 0 0 N 0 0 �f Z� N O 4 N N v o ui 40 vi Z Q N N 2 m m � N 07 D co z z r U1 a0 h N O a N N m w a N O O : C 5 �E ° 0 U O r I It ' ,o rno y � � O �m0 1 E0 0 0 N O N L Q p 0 o c z on O O r z O F U zw W C) d z O� V F LL O� W 3 m H v O a` d 3 w m 7 CO � Cq p c\ In N II U W Ln O zzz¢ O € H H F W h U O o O O o Y Q i w O N O m J Q � c IN N V IlI < Oi u E O N O V In ? � 2 H m V E m ti o YN o � n ocmn o S m S s u � n N N 10 W m U i a o m e rn o LL o a m o m w w > Q O c o 0 0 0 0 0 0 Q W k 10 n m n N f7 0 2" 000 O O O W ~ J L om0 T 0 � faD m W � � q _ J F � m m N O N C 10 < 10 ul tp N E O N O O O O a o v a L N �D O N Ol N C � 0 Nnm m m N com m m n m z 5 060 00 0 Ix U W Q W U N 0 w 0 N 0 N 0 N 0 N 0 z N O N N eolri v 0 Iri v z Q O N d' m m m � N m U) N z z m f 7 co O id N N N o w a co d z U U LL � N U O C N m E a— 'o O N (0 c E c U') f0 11 \ � U N } J C `O E U c) E 'c E QY� >m II Q II II C I I I r LL LL O Z M Y Q � w a w } F 0 y W J H Z O O w N Oq d W c � Cl Sox, I V7 Y a f W 6 N n J O O cq cq th O t7 M V to F d F W O EO C w G ° U U m aD of vi to A cp O N m N O m v m m M M C O N O m U U N tip N N N N U o 0 0 0 0 0 J N O N N Q A C O N O N N LL O o Z y O 7 m 0: N M R n b F m U N W 0.' s c rn c CL a ° z U LL L 0 U E O C y w E L C U g � N L O C N NO U "' N U co N C 0 co N 0 Q w C C a)] N C 0 � �` .O CIO II II II ` Ii CiUU �I Q O 0 I I Q w arz Cl Q = o W Z C 0 w` a ^� W 7 Oo lu o NN o Cl. z -• r, .- n U O co z C) z z�-. ¢ o w a U C) 0 0 ¢� Y K Q W K 6 N O '� 0a U m tV Oi Oi 0 r s N U d W O � E m c K O H 'O U � Cl? O N m N n a �, O m fV Oi Oi Cl � _ L IN r f00 N f0p N 06 (6 (6 ( r E 0 v v v U f7 W N lh lh o) U o 0 0 00 0 U N O N N Q 0 0 LL'1 O N N LL 0 O Z w b r r U U W 0 rn c .2) N '0 Q N N th o a a� 2 U LL 0 U E w O c � w 0UE L N ... r.. N � C U C � m � 'a N EE �p (p N N L T C N U N C 0) cc7 � (O 0 v C 000 ° Q O a I ". 9901917M10 RETENTION POND AND INFILTRATION BASIN CALCULATIONS C 1 0 1 1 1 1 1 1 1 MINIMUM DETENTION VOLUME REQUIRED (RETENTION POND 2) FAA METHOD (100-YEAR) LOCATION: PROJECT NO: COMPUTATIONS BY SUBMITTED BY: DATE: Equations: NBB Solix 110-15 ppk North Star Design, Inc. 3/5/2008 Qo = CA Vi = T*CiA = T*Qo V. =K*QPo*T S=Vi -V. Rainfall intensity from City of Fort Collins IDF Curve A trib. To pond = Cioo = Developed C*A = QPO K= 5.55 0.33 1.8 0.00 1 acre acre cfs (from fig 2.1) Storm Duration, T (min) Rainfall Intensity, i (in/hr) Qn (cfs) Vol. In Vi (ft') Vol. Out V0 (ft) Storage S (ft) Storage S (ac-ft) 5 9.95 18.2 5467 0 5467 0.13 10 7.72 14.1 8484 0 8484 0.19 20 5.60 10.3 12308 0 12308 0.28 30 4.52 8.3 14901 0 14901 0.34 40 3.74 6.8 16440 0 16440 0.38 50 3.23 5.9 17747 0 17747 0.41 60 2.86 5.2 18857 0 18857 0.43 70 2.62 4.8 20154 0 20154 0.46 80 2.38 4.4 20923 0 20923 0.48 90 2.22 4.1 21956 0 21956 0.50 100 2.05 3.8 22527 0 22527 0.52 110 1.93 3.5 23330 0 23330 0.54 120 1.80 3.3 23736 0 23736 0.54 130 1.60 2.9 22857 0 22857 0.52 140 1.40 2.6 21538 0 21538 0.49 150 1.20 2.2 19780 0 19780 0.45 160 1.15 2.1 20220 0 20220 0.46 170 1.10 2.0 20549 0 20549 0.47 180 1.05 1.9 20769 0 20769 1 0.48 Required Storage Volume: 23736 ft3 0.545 acre-ft NEW BELGUIM BREWERY Retention Pond 2 - Stage/Storage LOCATION: NBB Solix PROJECT NO: 110-15 COMPUTATIONS BY: ppk SUBMITTED BY: NORTH STAR DESIGN DATE: 3/5/2008 V = 1/3 d (A + B + sgrt(A*B)) where V = volume between contours, ft3 d = depth between contours, ft A = surface area of contour 100-yr WSEL- Stage (ft) Surface Area (ft`) Incremental Storage (ac-ft) Total Storage (ac-ft) 45 0 46 5292 0.04 0.04 47 11422 0.19 0.23 48.0 20746 0.36 0.59 48.80 33652 0.49 1.09 49.0 36878 0.65 1.24 49.5 45990 0.64 1.72 Total required detention = Total required retention = Total required detention = Total required retention = 0.54 Ac. Ft. 1.09 Ac. Ft. 23736 Cu. Ft. 47472 Cu. Ft. detention.xls NEW BELGUIM BREWERY Emergency Overflow Spillway Sizing LOCATION: NBB Solix PROJECT NO: 110-15 COMPUTATIONS BY: PPK SUBMITTED BY: North Star Design DATE: 3/5/2008 Equation for flow over weir Q = CLH-14Z where C = weir coefficient = 3.1 H = overflow height L = length of the weir too of berm b spill elevation f- L p 100 yr WSEL Spillway will be designed with max 0.5 ft flow depth, H = 0.5 ft Size the spillway assuming that the pond outlet is completely clogged. Retention Pond 2 Q (100) = 12.1 cfs Spill elev = 4949.00 ft Min top of berm elev.= 4950.00 Weir length required: L= 11 ft Use = 15 ft v = 1.61 ft/s 100 yr WSEL = 4948.80 ft detention.xis 1 1 1 1 1 1 1 1 1 1 i 1 1 1 i 1 1 MINIMUM INFILTRATION VOLUME REQUIRED FAA METHOD (100-YEAR) LOCATION: New Belgium Brewery - Solix Bio Fuels PROJECT NO: 110-15 COMPUTATIONS BY: TDS SUBMITTED BY: NSD DATE: 4/9/2008 Equations: A trib. To pond = 5.26 acre Qo = CiA C100 = 0.28 V; = T*CiA = T*Qo Developed C*A = 1.5 acre Vo=K*QPo*T QPo = 0.00 cfs �/ `i55d wi CS S = V; - vo K = 1 (from fig 2.1) N� o�Fro� Rainfall intensity from City of Fort Collins IDF Curve Storm Duration, T (min) Rainfall Intensity, i (in/hr) Qp (cfs) Vol. In Vi (ft) Vol. Out Vo (ft') Storage S (ft) Storage S (ac-ft) 5 9.95 14.7 4396 0 4396 0.10 10 7.72 11.4 6822 0 6822 0.16 20 5.60 8.2 9897 0 1 9897 0.23 30 4.52 6.7 11983 0 11983 0.28 40 3.74 5.5 13220 0 13220 0.30 50 3.23 4.8 14271 0 14271 0.33 60 2.86 4.2 15164 0 15164 0.35 70 2.62 3.9 16207 0 16207 0.37 80 2.38 3.5 16825 0 16825 0.39 90 2.22 3.3 17656 0 17656 0.41 100 2.05 3.0 18115 0 18115 0.42 110 1.93 2.8 18761 0 18761 0.43 120 1.80 2.7 19087 0 19087 0.44 130 1.60 2.4 18381 0 18381 0.42 140 1.40 2.1 17320 0 17320 0.40 150 1.20 1.8 15906 0 15906 0.37 160 1.15 1.7 16260 0 16260 0.37 170 1.10 1.6 16525 0 16525 0.38 180 1.05 1.5 16702 0 16702 0.38 Required Storage Volume: ft' 0.438 a e-ft 00101'vrf, 1 1 1 r i 1 1 1 i 1 1 1 i 1 1 1 1 1 1 North Star Design 700 Automation Drive, Unit I Windsor, SO 80550 STAGE - STORAGE TABLE FOR INFILTRATION BASIN LOCATION: New Belgium Brewery - Solix Bio Fuels PROJECT NO: 110-15 COMPUTATIONS BY: TDS SUBMITTED BY: NSD DATE: 4/9/2008 infiltration basin.xls Minimum Infiltration Basin Volume = 0.438 ac-ft Infiltration Basin �Stg Stage (ft) Surface Area (ftZ) Incremental Storage (ac-ft) Total Storage (ac-ft) 4944.5 9025 4945.00 1 9890 0.109 0.109 4946.00 11690 0.247 0.356 4946.30 12252 0.082 0.438 4946.50 12630 0.057 0.496 Stage -Storage - Onsite APPENDIX D EXCERPTS FROM PREVIOUS REPORTS 0 0 FINAL DRAINAGE & EROSION CONTROL STUDY FOR NEW BELGIUM BREWERY PROCESS WATER FACILITY Prepared for: The Neenan Company 2290 E. Prospect Road Fort Collins, CO 80522 Prepared by: North Star Design, Inc. 700 Automation Drive, Unit I Windsor, Colorado 80550 (970)686-6939 July 30, 2001 Job Number l f 0-07 i :j � m 0 /CL _ ■ �® 0 ! k ) ) § / » , §U § 0 U \U. 2 k ) coJ § \ / )§a§ £=E& k)2 J£§ .J2] co£ co\&E � to 6/ �7a /((.. E�E v20< §\§ SaEa I Wf) �k8 °J§ !2! � a{ Ssaa� / °§§§CD J§ aI [§;;G: 2; 2 a 0 LL ;;§ §§ § ƒ§- 8 §!F )�� \ «!F e;§ Q }k§[»4 /( ° §�# §§CY<_ o§o,,, , {, §af / I£ u CL ) (k § �C §q;�5 � � � v )!/ §q§§)d §c K � § .2.,_� £ �� // % a\ (\ k � /k � {� J / \\ # J | 7 kc E cc - �ƒO) 4a § fE 2 Jt q §o k ° | §\ ! Wv ! ) k Tv K J = � ) a E ) e% � §� \ ) ) g � ) �K c- §7-W _ z=.am , � � ( z z$§ /§2.. u3§M cli ! B - - @ ! ! 2 4\ ƒ 6 )Ci,6 \ �} )ea! a 2 !ww0) \ s „ri"d, k - k 3§§/§3 3 § 2 ® { § ■;# a fo < # k r! § !; ) £ \ e) § LL \ 2 \ aka m0 S (D _,=cc I @[GG §�/ ��\/a \ ) T u w N r N N Y n £ c c W K mx m 0 O^ to t7 N m m? tp n m n O F- 0 F O w W O � } E rn c Q O a U a co n n Q ci fV a N m ._ wi n t00 CO Omi 0 O m m _ 0 m w w Im tfi to h t0 t) C O N m O O to m m a ao M m N m of N p� p1 p� pNf p� U o 0 0 0 0 0 0 0 0 Q N O O m to Of v Q O N A O NU. M Ol PNf U. C L H m n v Z S W i~1 N G p � f � 0 c O C 'p a N t7 v m of o a ig dU to I -------------------------------------------- DETENTION POND SIZING BY FAA METHOD Developed by Civil Eng. Dept., U. of Colorado Supported by Denver Metro Cities/Counties Pool Fund Study Denver Urban Drainage and Flood Control District, Colorado PROJECT TITLE: Retention Pond 1 **** DRAINAGE BASIN DESCRIPTION BASIN ID NUMBER = 1.00 BASIN AREA (acre)= 4.41 RUNOFF COEF = 0.38 ***** DESIGN RAINFALL STATISTICS DESIGN RETURN PERIOD (YEARS) = 100.00 INTENSITY (IN/HR) -DURATION (MIN) TABLE IS GIVEN DURATION 5 10 20 30 40 50 60 80 100 120 150 180 INTENSITY 9.9 7.7 5.6 4.5 3.8 3.2 2.8 2.4 2.1 1.8 1.2 1.0 ***** POND OUTFLOW CHARACTERISTICS: MAXIMUM ALLOWABLE RELEASE RATE = 0 CFS OUTFLOW ADJUSTMENT FACTOR = 1 AVERAGE RELEASE RATE = 0 CFS AVERAGE RELEASE RATE = MAXIMUM RELEASE RATE * ADJUSTMENT FACTOR. ***** COMPUTATION OF POND SIZE RAINFALL RAINFALL INFLOW OUTFLOW REQUIRED DURATION INTENSITY VOLUME VOLUME STORAGE MINUTE ----------------------------------------------------- INCH/HR ACRE -FT ACRE -FT ACRE -FT 0.00 0.00 0.00 0.00 0.00 5.00 9.95 0.12 0.00 0.12 10.00 7.72 0.18 0.00 0.18 15.00 6.66 0.23 0.00 0.23 20.00 5.60 0.26 0.00 0.26 25.00 5.06 0.29 0.00 0.29 30.00 4.52 0.32 0.00 0.32 35.00 4.14 0.34 0.00 0.34 40.00 3.75 0.35 0.00 0.35 45.00 3.47 0.36 0.00 0.36 50.00 3.20 0.37 0.00 0.37 55.00 3.01 0.39 0.00 0.39 60.00 2.82 0.39 0.00 0.39 65.00 2.71 0.41 0.00 0.41 70.00 2.60 0.42 0.00 0.42 75.00 2.49 0.43 0.00 0.43 80.00 2.38 0.44 0.00 0.44 85.00 2.30 0.45 0.00 0.45 90.00 2.22 0.46 0.00 0.46 95.00 2.13 0.47 0.00 0.47 100.00 2.05 0.48 0.00 0.48 105.00 1.99 0.49 0.00 0.49 I_l P 110.00 1.93 0.50 0.00 0.50 115.00 1.88 0.50 0.00 0.50 120.00 1.82 0.51 0.00 0.51 125.00 1.72 0.50 0.00 0.50 130.00 1.61 0.49 0.00 0.49 135.00 1.51 0.47 0.00 0.47 140.00 1.40 0.46 0.00 0.46 145.00 1.30 0.44 0.00 0.44 150.00 ----------------------------------------------------- 1.19 0.42 0.00 0.42 THE REQUIRED POND SIZE _ .508326 ACRE -FT THE RAINFALL DURATION FOR THE ABOVE POND STORAGE= 120 MINUTES NEW BELGUIM BREWERY Retention Pond 1 - Stage/Storage LOCATION: New Belguim Brewery Wastewater Treatment Pond PROJECT NO: 110-07 COMPUTATIONS BY: ppk SUBMITTED BY: NORTH STAR DESIGN DATE: 7/30/01 100-yr WSEL- V = 1 /3 d (A + B + sgrt(A'B)) where V = volume between contours, ft3 d = depth between contours, ft A = surface area of contour Stage (ft) Surface Area (fe) Incremental Storage (ac-ft) Total Storage (ac-ft) 44 0 45 12015 0.09 0.09 46 14508 0.30 0.40 47.0 17174 0.36 0.76 47.54 24798 0.26 1.02 48.0 31293 0.55 1.31 48.5 44518 0.75 1.77 Total required detention = 0.510 Ac. Ft. Total required retention = 1.020 Ac. Ft. Total required detention = 22216 Cu. Ft. Total required retention = 44431 Cu. Ft. ww detention.xls i i 1 i 11 --------------------------------- DETENTION POND SIZING BY FAA METHOD Developed by Civil Eng. Dept., U. of Colorado Supported by Denver Metro Cities/Counties Pool Fund Study Denver Urban Drainage and Flood Control District, Colorado PROJECT TITLE: Retention Pond 2 **** DRAINAGE BASIN DESCRIPTION BASIN ID NUMBER = 2.00 BASIN AREA (acre)= 5.05 RUNOFF COEF = 0.29 ***** DESIGN RAINFALL STATISTICS DESIGN RETURN PERIOD (YEARS) = 100.00 INTENSITY(IN/HR)-DURATION(MIN) TABLE IS GIVEN DURATION 5 10 20 30 40 50 60 80 100 120 150 180 INTENSITY 9.9 7.7 5.6 4.5 3.8 3.2 2.8 2.4 2.1 1.8 1.2 1.0 ***** POND OUTFLOW CHARACTERISTICS: MAXIMUM ALLOWABLE RELEASE RATE = 0 CFS OUTFLOW ADJUSTMENT FACTOR = 1 AVERAGE RELEASE RATE = 0 CFS AVERAGE RELEASE RATE = MAXIMUM RELEASE RATE * ADJUSTMENT FACTOR. ***** COMPUTATION OF POND SIZE RAINFALL RAINFALL INFLOW OUTFLOW REQUIRED DURATION INTENSITY VOLUME VOLUME STORAGE MINUTE ----------------------------------------------------- INCH/HR ACRE -FT ACRE -FT ACRE -FT 0.00 0.00 0.00 0.00 0.00 5.00 9.95 0.10 0.00 0.10 10.00 7.72 0.16 0.00 0.16 15.00 6.66 0.20 0.00 0.20 20.00 5.60 0.23 0.00 0.23 25.00 5.06 0.26 0.00 0.26 30.00 4.52 0.28 0.00 0.28 35.00 4.14 0.29 0.00 0.29 40.00 3.75 0.31 0.00 0.31 45.00 3.47 0.32 0.00 0.32 50.00 3.20 0.33 0.00 0.33 55.00 3.01 0.34 0.00 0.34 60.00 2.82 0.34 0.00 0.34 65.00 2.71 0.36 0.00 0.36 70.00 2.60 0.37 0.00 0.37 75.00 2.49 0.38 0.00 0.38 80.00 2.38 0.39 0.00 0.39 85.00 2.30 0.40 0.00 0.40 90.00 2.22 0.41 0.00 0.41 95.00 2.13 0.41 0.00 0.41 100.00 2.05 0.42 0.00 0.42 105.00 1.99 0.43 0.00 0.43 110.00 1.93 0.43 0.00 0.43 115.00 1.88 0.44 0.00 0.44 120.00 1.82 0.44 0.00 0.44 125.00 1.72 0.44 0.00 0.44 130.00 1.61 0.43 0.00 0.43 135.00 1.51 0.41 0.00 0.41 140.00 1.40 0.40 0.00 0.40 145.00 1.30 0.38 0.00 0.38 150.00 1.19 0.36 0.00 0.36 ----------------------------------------------------- THE REQUIRED POND SIZE _ .4442317 ACRE -FT THE RAINFALL DURATION FOR THE ABOVE POND STORAGE= 120 MINUTES NEW BELGUIM BREWERY Retention Pond 2 - Stage/Storage LOCATION: -- New Belguim Brewery Wastewater Treatment Pond PROJECT NO: 110-07 COMPUTATIONS BY: ppk SUBMITTED BY: NORTH STAR DESIGN DATE: 7/30/01 100-yr WSEL- V = 1 /3 d (A + B + sgrt(A-B)) where V = volume between contours, ft3 d = depth between contours, ft A = surface area of contour Stage (ft) Surface Area (ft!) Incremental Storage (ac-ft) Total Storage (ac-ft) 45 0 46 5292 0.04 0.04 47 11422 0.19 0.23 48.0 20746 0.36 0.59 48.50 28812 0.28 0.88 49.0 36878 0.65 1.24 49.5 45990 0.85 1.73 Total required detention = 0.44 Ac. Ft. Total required retention = 0.88 Ac. Ft. Total required detention = 19166 Cu. Ft. Total required retention = 38333 Cu. Ft. ww_detention.xls NEW BELGUIM BREWERY . Emergency Overflow Spillway Sizing LOCATION: New Belguim Brewery Wastewater Treatment Pond PROJECT NO: 110-07 COMPUTATIONS BY: PPK SUBMITTED BY: North Star Design DATE: 7/30/01 Equation for flow over weir Q = CLH' where C = weir coefficient = H = overflow height L = length of the weir tOD of berm H 3.1 spill elevation f— L -� 7 100 yr WSEL Spillway will be designed with max 0.5 ft flow depth, H = 0.5 ft Size the spillway assuming that the pond outlet is completely clogged. Pond 1 Q (100) = 11.5 cfs Spill elev = 4948.00 ft 100 yr WSEL = 4947.54 ft Min top of berm elev.= 4948.50 Weir length required: L= 10 ft Use L = 10 ft v = 1.59 ft/s Pond 2 Q (100) = 9.8 cfs Spill elev = 4949.00 ft 100 yr WSEL = 4948.50 ft Min top of berm elev.= 4949.50 Weir length required: L= 9 ft Use L = 10 ft v = 4.90 ft/s ww detentionAs SUBSURFACE EXPLORATION REPORT GEMINI: SOLIX AT NEW BELGIUM BREWERY FORT COLLINS, COLORADO EEC PROJECT NO. 1072091 11 11 110 - IS Frayl 0-NA/S EARTH ENGINEERING CONSULTANTS, INC. 13 North Not to Not AREA so- 50,475 S.F. V) II LUU ui g ul I II BLD. a METHANE TANK OFFSET ------------ W 9-6 �\w p LEGEND FO-SITE PHOTO [I$�B-2 BORING LOCATION PHOTOS TAKEN MM APPROXIMATE LOCATION, IN DIRECTION OF ARROW BORING LOCATION DIAGRAM NEW BELGium ALGAE BEDS FORT COLLINS, COLORADO EEC PROJECT #: 1072091 DATE: OCTOBER 2007 NEW BELGIUM ALGAE BEDS. FORT COLLINS, COLORADO PROJECT NO: 1072091 DATE: OCTODER2007 LOG OF BORING 04 RIG TYPE: CME45 SHEET 1 OF 1 WATER DEPTH FOREMAN: DG START DATE 1011 2007 WHILE DRILLING 4' AUGER TYPE: 4' CFA FINISH DATE 1=24r2007 AFTER DRILLING NIA SPT HAMMER: MANUAL APPROX SURFACE ELEV 4947 24 HOUR NIA SOIL DESCRIPTION D N DU Nc DO AUNTS .me SWELL F LL N PRESSURE % IN PSF TYPE (FEET) @Lowawrl (Pa AI (PcFl (%) FILL MATERIALS: Clayey Send With Gravel, 1 organic, root growth 2 3 CS 1J 9.1 95.7 NL NP 94 <500 par None SILTY SAND with GRAVEL _4_ Drown I red I grey dense _ _ —a— 60R 7.6 SS SS 6 _8 —7- 8 ' IrdermitteM COBBLES with Depth 9 Ess 10 Sow 7.9 11 12 13 14 S' or cave in (No Drive Taken at 14') 16 18 GRAY CLAYSTONE 17' AUGER CLIPPINGS 17 17.2 BOTTOM OF BORING DEPTH 17' 1B 19 20 21 23 24 25 wtll ^ /7/ nu G O 26 27 28 29 JO 31 32 33 1 N c� r 1 rj 34 �1/ hl7J 36 36 Earth Engineering Consultants