Loading...
HomeMy WebLinkAboutDrainage Reports - 09/11/1990F Final Drainage Report for LOT 2, THE MARKET AT HORSETOOTH COMMONS Ft. Collins, Colorado Prepared for: KENT GOODMAN 145 West Swallow B-2 Ft. Collins, Colorado 80525 Prepared by: SHEAR ENGINEERING CORPORATION 4836 South College Avenue Suite 12 Ft. Collins, Colorado 80525 Phone: (303) 226-5334 Project No: 1200-1-90 Date: September, 1990 4836 S. College, Suite 12 Fort Collins, CO 80525 (303)226-5334 > IBM i FINAL DRAINAGE REPORT LOT 2, THE MARKET AT HORSETOOTH COMMONS PROJECT NO: 1200-1-90 I GENERAL LOCATION AND DESCRIPTION A. Property location 1. Lot 2 of "The Market at Horsetooth Commons P.U.D." is located in the Southeast Quarter of Section 27, Township 7 North, Range 79 West of the Gth P.M., Larimer County, Colorado. 2. More specifically, Lot 2 is located on the Southwest corner of the intersection of Shields Street and Richmond Drive, in the City of Fort Collins, Colorado. B. Description of Property 1. The site has an area of approximately 0.78 acres. 2. The lot is currently vacant and has native vegetation. 3. This lot will be the first lot of the five lots to be developed within the Market at Horsetooth Commons development. Street curb and gutter already exists around this lot. With the exception of the west side of the property, all the street sidewalk is existing. 4. There is an existing 36 inch R.C.P. storm sewer line in an existing 20 foot wide utility and drainage easement which runs the length of the lot, on the east side adjacent to Shields Street. The lot has water and sanitary sewer services stubbed into it on the west side. S. The development of the site will include an office/retail building with approximately 4000 square feet and a retail/showroom building with approximately 3100 square feet. There will be an outdoor display area around the east end of the retail/showroom building which is intended to be a specialty auto retail outlet. Our understanding is that the display area will be surfaced with a design block that allows lawn grass to grow in the block openings. There will be 1 driveway curb cut along the west side of the lot,, leading into an asphalt parking lot that will be. shared by the 2 buildings. II DRAINAGE BASINS AND SUB -BASINS A. Major Basin Description 1. The site is situated in Basin "G" of the Foothills Drainage Basin as identified in the 1981 Basin Master Plan prepared by Resource Consultants, Inc. B. Sub -Basin Description 1. Redpeak Engineering of Windsor, Colorado prepared a drainage study for "The Market At Horsetooth Commons P.U.D." addressing all 5 lots. The study was prepared in May, 1987 and revised in June, 1987. Redpeak Engineering refers to this site as Tract "D" Area II, containing 0.78 acres with a storm runoff concentration point at Inlet RS. This inlet is in the southwest corner of the Richmond Drive and Shields Street intersection. Redpeak's comments about this site are "Area II detention to be completed at a future date". A copy of the drainage study for the Market at Horsetooth Commons is included in Appendix 8 of this report for reference. PAGE 2 Project No: 1200-1-90 Lot 2, The Market at Horsetooth Commons III DRAINAGE DESIGN CRITERIA A. Regulations 1. This report and the drainage and grading plan were prepared in accordance with the requirements of the City of Fort Collins storm drainage design criteria. B. Development Criteria Reference and Constraints 1. This Lot requires its own site specific detention facility according to the drainage study for The Market At Horsetooth Commons. See Appendix B of this report. 2. One of the primary constraints of this site is that all adjacent streets are in place. These generate a relief of over 4.50 feet from the high point of 82.68 at back of walk on the south side, to 78.10 at the back of walk in the northeast corner, and the high point of 82.86 at back of walk on the west side to the same point of 78.10 in the northeast corner. In order to provide the needed detention area, yet not create side slopes along the east and north sides that would defy maintenance, it is necessary to keep the site improvements at as low an elevation as possible. The existing 36" storm adjacent to the site allows flexibility in the design of the site and proposed detention pond. C. Hydrologic Criteria 1. Runoff calculations are based on the "Rational" method. 2. Detention volume requirements are based on the cumulative runoff method. D. Hydraulic Criteria 1. Detention pond outlet is based on the orifice equation. IV DRAINAGE FACILITY DESIGN A. General Concept 1. The drainage design concept for this portion of the Market at Horsetooth Commons development as proposed by Redpeak Engineering is still applicable. On -site detention will be provided to meet lot specific needs. Parking lot grading will be designed to maximize detention volumes. The detention pond outlet will utilize the existing storm sewer which parallels Shields Street. B. Specific Details 1. Final site grading design considered all existing grades and adjacent street improvements. A majority of the stormwater generated within the limits of this site will be directed to the detention area (parking lot). 100% of the site runoff will not be conveyed to the detention area due to reasons which are discussed in greater detail to follow. 2. The existing 36" storm sewer paralleling Shields Street, allowed flexibility in grading design to acheive required detention volumes, as well as providing a reasonable detention pond outlet design. 3. The minimum finished floor elevation for each structure was established to not only protect the structures from stormwater, but to render logical and maintainable slopes between them and the adjacent street improvements. PAGE 3 Project No: 1200-1-90 Lot 2, The Market at Horsetooth Commons IV DRAINAGE FACILITY DESIGN (continued) B. Specific Details (continued) 4. A concrete drainage pan will convey a majority of the stormwater generated on the southern portion of the property, to the southeasterly corner of the parking lot. The drainage pan which carries the flow for sub -basin A-2 (0.45 cfs) was sized using the manning equation. The concrete pan has a carrying capacity of 0.42 cfs. The landscaping berms will deflect the difference of 0.03 cfs to the parking lot. See sub -basin A-2 data and illustration in the appendix of this report. The concentration point for this sub -basin is shown on the illustration, as well as the contributing flow to that point. 5. A small amount of runoff from a portion of Lot 2 is conveyed undetained from the site. The two (2) specific areas which release stormwater undetained are designated as sub -basin A-1 and sub -basin A-3 in this report. The data, as well as the illustrations for these sub -basins, are contained in the appendix of this report. The runoff from these sub -basins is conveyed to the existing inlet located on the Southwest corner of the intersection of Shields Street and Richmond Drive. Contributing flows to the inlet are shown on the illustrations. V CONCLUSIONS A. Compliance With Standards 1. The grading and drainage design meets the City of Fort Collins storm drainage design criteria. The design remains consistent with the drainage concept for this portion of the Market at Horsetooth Commons as submitted by Redpeak Engineering and approved by the City of Fort Collins. B. Specific Details 1. Final grading of the site was keyed to the driveway on the west side. The driveway slopes 6% from the street into the parking lot. 2. A stormwater inlet has been located in the middle of the parking lot to maximize the detention area and volume within the parking lot. 3. The inlet will contain an orifice plate with a 3.00" diameter orifice (see calculations in Appendix A). The orifice will release 0.41 cfs (2-year historic runoff = 0.42 cfs). The orifice plate detail has been included in the appendix of this report for reference. It has also been included on the detail sheet for the sitework drawings for Lot 2, the Market at Horsetooth Commons. 4. The discharge pipe leaving the inlet will be an B" P.V.C. pipe. The size was selected for ease of maintenance. Stormwater will travel approximately 51 feet from the inlet to a proposed 5' manhole installed over the existing 36" R.C.P. storm sewer main. PAGE 4 Project No: 1200-1-90 Lot 2, The Market at Horsetooth Commons V CONCLUSIONS (continued) B. Specific Details (continued) 5. The detention pond high water line will be at an elevation of 80.2, established by a minimum berm elevation along the east side of the parking lot. Grading along the east side of the parking lot incorporates additional berming to meet the landscaping plan design. The minimum berm elevation of 80.20 will result in a maximum parking lot depth of 1.SV , meeting City requirements. 6. The rim elevation of the parking lot inlet will be 78.70 feet, with an invert elevation of 75.92 feet. This will allow for detention storage of 4,314 cubic feet, which is 86 cubic feet more than the 4,228 cubic feet required (see Appendix A). 7. A concrete drainage pan will convey the flows for sub -basin A-2 to the detention area. A detail of the proposed concrete pan is included in the appendix of this report. It is also included on the detail sheet of the sitework drawings for Lot 2, the Market at Horsetooth Commons. VI REFERENCES A. City of Fort Collins storm drainage design criteria and construction standards. B. City of Fort Collins files for Horsetooth Commons P.U.D. and The Market At Horsetooth Commons P.U.D. C. Foothills Basin (Basin G) Drainage Master Plan, by Resource Consultants, Inc. D. Drainage Study for Horsetooth Commons Tract D (The Market At Horsetooth Commons); Redpeak Engineering; APPENDIX A I &14elt'ET_../r- TOO..Ti/ �./i�1M..O�✓S_. WA WC5 .._'57 y - _.--------- - -- - 1 II %5'clll9f2G_E _I '1 _-.--..---.-- 2/.C....rPu!✓0...4=4=.__.COE,F.F/_C/_EDIT.............____....- i 1° ! I - --- - .... _._ .__,1 ...1 - -� Ii 14 1J T-o9-9or r2or�- �-90 17 1° 00 21 23 24 Ij r 27 !I 9.N_.G.ES7_..._T..4fl✓.-EL.1>/_.S_.T.AN_C.E___ )17.Co.__-_187_�L/_-. 50 iz-,4 i - 0 —,cA .............. . ....... . .......... — ....... ............ .. . .......... 07- 09 -90 S i- c c• Tn n n i- c �^ // n i i r- /.50 01/ERFLOW5 BERM /A/ oyE. COR. OFPRA-6 LOT 80.20 14/ ;60. 00 X M O � N � Q W tl� 0.30 79.00 d W 78..70 0 /, 000 4?,000 3, 000 4.000 5, 000 STORAGE ��'f s� ' CUMUL,4 MC CUMULAT/I/E 57A6E CONTOUR AREA VOL UME VOL UME l/OL UME �i'`) �ft z) ft 3 { f 9 ACRE -FEE O 78.70 O /03 /03 0.003 0.30 79.00 /026 364/ 3744' '_ 0.086 1.4/ 80.00 5535 .570 4514 0.0 99 /.SO 80.20 7/28 SQUAT/ON: DEPTH X AREA = 1/OL UME j i L_o_r_2, Gi2MMOM5' I = ' _N1AR�E_T__A_ _T__i'iO_R_S_E_T_.D.QT_H i 7 09-90,. MA,S'a OlAGRANI CAL C 'S . ......... RUNOFF RA/ IAWLL i ✓_OLUME_._RELER.SE_P._ONO...G. ...... ...,....Q...Z6__.... _.-._._6.-O._..__.-- ----O..-ZB.._...__.__9O.O__ . _.4 20/. _._ .....___.3...7.8.._...2,823__. _...4,482._ __ .7510..._- .3� TZG.--- r 103GZ._ __l43 .... _.4,228__ ._.-. ---._-_./.._87_..... ..... O_:-78_-- _3, .Z6....... _.... .___ 0.78 - .--.7_, __3, 4Z4 ... ,3p./ZZ_.... _l80._..... . _.._O..T6.---....._..-_ __ L•OS._-- -_O_._7.8____ __.-__._._.._._....__..__ .._-.-..._.._..__.___..._.-___.--.------.__-.-_------------_.,--------.___...__-.___..T.__. 22_ 20 2_4; 2.6 27 No Text �sTNv_,esEra�r_,y catirMovs P,_ IrEr;BY u U,., ----------- -----_._._.._-_.----__-._. �D_✓_�!_O_.__/_ZOO._ O/�.90__.._ 'I ._.._..__Q=-- ,° „ ----.._.............. _._-.,,siziw 13 1.7 ,_._.__..__..___..._.... CRA.v..�.rf/_/TKO.N.4L__/��'e.EC.,E._C<aTl_oN.-C,•J�tJ=-�Z_/�-->-.f�GLGr+It.JB_LE , 7.:; _..._...__--_---.._.__._.__;____Q...—_�4�..5� �o._a5��?C3�.Z�_�3...-.GL� �o_._G_G._2_.._.__.____o•-.¢./..,_cfs___._.___._____.._ ,; 22 ----- �3 _..3...4. _Q—U/Atit4L72F 2 E10E_.P-.LiJTE.._ a_ _._....... _..... —____..__..___.—_._.______-__.____.-- 21 I CE%G/E,c%T ------- ----- - t RICHMON® DRIVE O = `C�= 0,25 = �• /4 c�'s' /80' � j T /BM�,�Q �c � I � III I 80 to III F.F. = 80.50 �o 79 O ' I' (min.) III o 790 III ej`s i 81 23 POiVd UOr GIMP' III oar I 4(a,50 HT 3:: , . II I III \ I I 1 qq III I ' ' ' ' it�na• ,. ' ?At CC III 92 $dd4� � , ' o I it 9li' 8!'_1 III III III 8j9j I II 1 30' II , 77 a 8p 41 4 80 9 it I I I 8�65 8DV I II ti I F.F= 80.50 I II I (min.) �ff-I 82 30 Z _-- �- /�� _�� BZse 0ti —="iT i I W to I I t �=7750 MH /NY. - 73'ik %B. D.W. - 79 �O r uj uj 0 Lu g c EllGOT •-- Z_,Jh���vl�I.e�ET_/n_fb�eEo-rh� COirNtONS !JT/L✓TY �PEO G/.CIES aF 7�/7 .FO • 1'�.i1FU.P - \ �_— �J -- - 9 2 - v 3 4 - 6 7 - of �i 1o. AO✓t/s TEO .F�t/.1lOFF G'OEFF/C/Eit/ r =CSC X Cr = O. zS J �� T/ME of CIJ.VCEA/TRAT/rJ.tl = T 87) ('/3 ¢Z) _ /S 2 3 MZa/ /,/7 ,s RA/.VFALG dZ7-;;6,U.6/TY = / = sEE =Ia._.6 = S.So , ° =CC) ) = Co. 2s) 6s sZCo. /off _ 'o 21 23 <<I 25 `6 2 81 30` I vZoo-of-,�o I - I m I I Rl;QHM®,ND DR.I!!E � I I I I I 1. )ff-77V I I ------- ------ —J— MH/NY.•73 -------------------�- --� / �� ra.0.w.•790 F.F=80.50 (min.) 8173 811.3 F.F= //"82su / LeZZ o - 82s$ a� I e01° I Y9�a LO 90 G0 ST I i it I I I II I I I III � n I I {LLJ t I I I GC i t ch I I n I I u I I � uj l t I = II I II jt I A. .1,F Ac. 1 S= 907 II IO= 47' it I Ca�.6Z II T = V4. 5 MIN. II q=i .45cfs 11 I I I I I I I A —2 PnGE t-7V —,,W K) lly;- 2 3 II 6 A vc� , -,6/- == 7 1AZO&S—E iri it -Z 12 Z- Amp0. 075 1 eq-41,47 t—c7/-ldl6 &!IVIO62cs 0 pis -3 — a 0. 95" is 7-on4l,: C2.113 iG 17 0,0-75X-O. (/,0. 0/ x A17- AA C 7-0,4? 20 I 0 22 199E 010= CoAl 23 7,4 0.,00) Is. 7,�) "IAJ. C7&-U- 1 0-97 25 654E 516, 3-1) CO. 0 7 I.c 46' ifs 27 23 !RICHMOND DRIVE. 4= 0. 51CA _ -- _—__—_—____—__—__—______—__--_—_—_—__—___—___—_—___—___—_— � III 80 !° III III. � F. F = 80.50 79 o (min.) ,o 79 �� II '. III III es �s s , : O 'at:; ` ;:670-- 'O,'�.. t:i. 4t',,•tty1?�p,:•;Yl, .y. d � .. } I 1 1� 30t r-- 4? d0b III I j N I F.F= 80.50 min:) `. az L / ---- / /$zoo ti =ae / G SI8_0 ® 13/aa ro I I I I I I I I 7750 I I —J— MH/NY.-73Ol tB.0.W.-70LO ♦ \ IA=0.07Ac. \ , \0 ,0= $00' \ 11IIIT=/oA/IV.II �I !QT.=0.5/cis i'i M Mi No Text 1,07-7 2 311 Z71.r7-,4A1e--,:a = 12 =,600" 4 E4A=-V =SQ, SO 77,5j2 = F. (90, .4 vG - FLo?=E = 5 = /. 00 70 A.,ee,4 OF fZ.1,e-e,461AJ 4-S = 0. 07 ACRES 0. AVJZk57-V RZJAIO OCFF= C ^ =0 9 _S' je 00 00 12 7, .5-4) 0 AIIAII17-6-5 IeD lcd&o /0.0,0 "VAIZ17-eS 15 is Cgee eov = Cz A = rl. 0) ("7 -6) rO. 0 7) 20 21 I COMA42EA17�: PAA!� A-*A/,OL4/ 77/65" A"121-IA17- Cl= WA777�� d2 hF-C- CQR-AXfff!!?7� C26&Y /,-' 7714F 4d��>O' 2-4 77:4647- 24 25 27 r X ° Q lz C�j N D Al, O 06 *49Z = AIVI A/ 22'AZ = A /V/ M .;W07,9=.*79N1Y 26 :91- = -77 -L b�-7k CZ 'R./ ='7 9 -7- Z VeY i ' N .-/O >v Oo- 86 t0 0. - -0.9 = ! 0 dO B90.9 069L f 0, .41 W � odd �ld7dsio, � � N C -109.9a9 061sSt0 � q` 3 odd .�d�dsio . N Os os = YO g90-q Os -se -AO, i armed ,cd7ds/0 �i1b'/77 7/b'OH /O 1 bVl y O Az'op Nfwd 9NL�0 Q kx 0,9 = 1/4/ON 9749 OO tO, 0 o ri o U No Text APPENDIX B a DRAINAGE STUDY FOR HORSETOOTH COMMONS TRACT D (THE MARKET AT HORSETOOTH COMMONS) Prepared by Redpeak Engineering May, 1987 Revised June, 1987 TABLE OF CONTENTS I. Introduction . . . . . . . . . . . . . . . . . . . . . . . . I II. Methodology . . . . . . . . . . . . . . . . . . . . . . . . I III. Baseline Hydrology . . . . . . . . . . . . . . . . . . . . . 1 Offsite Flows . . . . . . . . . . . . . . . . . . . . . . . 2 Onsite Flows . . . . . . . . . . . . . . . . . . . . . . . . 2 Detention Requirements . . . . . . . . . . . . . . . . . . . 8 Shields Storm Sewer . . . . . . . . . . . . . . . . . . . . 10 APPENDIX Figure 1 - Utility Map . . . . . . . . . . . . . . . . . . . 12 Figure 2 - Foothills Basin (Basin G) . . . . . . . . . . . . 13 Figure 3 - Drainage Basins 6 Improvements . . . . . . . . . . 14 a Figure 4 - Fort Collins Time of Concentration Curves . . . . 15 Figure 5 - Fort Collins Intensity Curves Figure 3-1 . . . . 16 Figure 6 - Nomograph for Round Pipe Flowing Full . . . . . . 17 ii I. Introduction The Market at Horsetooth Commons is a proposed commercial development located in the Southeast Quarter (1/4) of Section 27, Township 7 North, Range 69 West of the 6th Principal Meridian in Fort Collins, Colorado. The development is located within Tract "D" of the Horsetooth Commons Subdivision, which is located at the Northwest corner of Horsetooth and Shields. (See Figure 1.) The proposed site is approximately 5.47 acres and is situated in Basin "G" of the Foothills Drainage Basin as identified in a 1981 Basin Master Plan prepared by Resource Consultants, Inc. (See Figure 2.) . Some drainage work has already been completed which will affect this site. A 36" concrete storm sewer will be constructed along the East boundary of the project adjacent to Shields as recommended by the Foothills Basin Master Plan. Also, a temporary pond for Block I of the Horsetooth Commons Subdivision was to be located in this development. This drainage will need to be incorporated into the Tract "D" improvements. II. Methodology a The Rational Method of determining runoff was used to establish the drainage information in this report. The Rational Method is recognized as an excellent method of calculating flows from sites less than 150 acres. This method is acceptable for the Horsetooth Commons PUD since this area is less than twenty (20) acres. Rainfall intensities and runoff coefficients were developed from the Fort Collins "Storm Drainage Criteria and Construction Standards" (FCSDCCS) and from the Denver Urban Drainage and Flood• District's "Urban Storm Drainage Criteria Manual". III. Baseline Hydrology — Existing Conditions The Market at Horsetooth Commons (Tract "D") is currently vacant land which drains from West to East at a 1% slope. The site has a native hay ground cover. Flows now generally run from West to East on this site. Off -site Flows The reconstruction of Horsetooth and Shields adjacent to the site had some impact on drainage patterns which must now be taken into account. Horsetooth Road abuts the southern side of the property. Flows from Horsetooth flow to an inlet at the Northwest corner of Horsetooth and Shields where they exit via a sidewalk chase onto Tract "D". To the East, Shields Street takes flows northerly to a swale at the proposed Richmond Drive intersection which eventually are contained on Tract "A". Flows from both of these areas will be diverted to the proposed 36" storm sewer as it is constructed. The preliminary drainage study completed for Tracts A, B, C and D of the Horsetooth Commons Subdivision showed each tract detaining flows. This concept is still true except Tracts B (Block I) and D will be combined and Tract "D" will be split into six separate drainage areas. A summary of off -site flows is as follows: A. Approximately 2.8 cfs of water develops from Horsetooth Road in the 100 Year Storm. This area is further defined as the North 1/2 of Horsetooth Road from Richmond Drive to the west about 250'. This area west of Richmond Drive drains along Richmond Drive and is diverted into the 36" storm sewer at the inlet at the east edge of this site. Point of Concentration is Inlet RN. B. A portion of the flows from the west side of Horsetooth run to an inlet at the NW corner of Horsetooth and Shields. This area is further defined as the North 1/2 of Horsetooth Road from Shields to Richmond Drive. This will be connected to the 36" storm sewer as identified in the Foothills Basin Master Plan. This is approximately 6.0 cfs in the 100 Year Storm. Point of Concentration is Manhole J-3. C. Flows from the west side of Shields Street between Horsetooth and the proposed Richmond Drive are routed through an inlet at the east edge of the site. This is approximately 8.0 cfs in the 100 Year Storm. Point of Concentration is Inlet RS. On -Site Flows The Market at Horsetooth Commons will provide detention for Block I and a portion of Tract "D". The temporary pond for Block I will be incorporated into the Tract "D" improvements. Block I flows will be collected by a storm sewer which will take the 100 Year Storm under Richmond Drive and into the proposed parking lot detention in Area I of Tract "D". 2 A summary of these subbasins follows. Figure III shows these subbasins as they are proposed. Area Concentration Subbasin (Acres) Point Proposed Use Comments Block I * 3.29 Inlet #H-5 Multi -family 100 Year Flood carried via 24" pipe where it empties into Detention Pond A. Tract "D" Area I * 1.95 Inlet #H-3 Retail Parking lot Detention Pond A. Tract "D" Area II .78 Inlet RS Restaurant Area II detention to be completed at a future date. Tract "D" Area III .80 Inlet C-1 Convenience Store Detention Pond B Tract "D" Area IV .53 Inlet H-3 Retail Area IV detention to be completed at a future date. Tract "D" Area V .71 Inlet H-4 Office Area V.detention to be completed a at a future date. Tract "D" Area VI .70 Inlet H-3 Restaurant & Retail Area VI detention to be completed at a future date. Total 8.76 Acres *These areas will combine flows which will be detained in Pond "A". The detention Pond A will be responsible for detaining water from Block I and Tract "D", Area I. Water from Block I is routed to Pond A initially by a 24" storm sewer under Richmond Drive. This storm sewer will pass the 100 Year Flow of approximately 17 cfs flowing about 95% full. Once under Richmond Drive, the storm sewer empties into a 200 foot section of grass lined channel. (Calculations for this channel are attached.) This channel will flow about 1.5' full in the 100 year 3 event. The channel takes flows to another 24" storm sewer which runs under the parking lot and outlets into inlet H-3. an orifice plate jwith a 6" opening will limit flows outleting from inlet H-3. An 18" pipe will take these flows from inlet H-3 to the Foothills Basin 36" storm sewer along the west side of Shields. The 6" orifice will restrict flows from Pond A to 2.2 cfs when the pond is full. The 18" outlet pipe will carry considerably more water than 2.2 cfs, however, is sized larger for maintenance purposes. It should be noted that Areas IV, V and VI will detain flows on site. These historical releases will be made through the 24" storm sewer under the parking lot. The orifice plate may need to be modified for these historical flows at that time. Richmond ,Drive The capacity of 1/2 of Richmond Drive is approximately 11.3 cfs. This is adequate to carry any flows developed in the 100 Year Storm. Capacity calculations are attached. 4 Undeveloped Conditions Area including Block I 6 Area I Basin Length = 960 feet Basin Drop = 91.0 - 79.0 = 12 feet Average Slope = 1.25% Tc = 1.87 (1.1 - C Cf) D1/2 = 1.251/3 1.87 0 .1 - (0.4)(1.0)) 9601/2 = 40.56 = 37.7 min. (1.25)1/3 1.077 Runoff Coefficient (C) = 0.30 See page 300 Table 10-9 "Water in Environmental Planning". Time of Concentration (Tc) = 37.7 Min. Intensity (I)2 = 1.3 in./hr. Figure 5 Area (A) = 5.24 Acres Frequency Factor (Cf) = 1.00 Table 3-4 Q2 = Cf CIA Q2 = 1.00 (.30) 0.3) (5.24) = 2.04 cfs Q100 = (1.25)(0.30)(3.6)(5.24) = 7.07 cfs Area III Basin Length = 240 feet Basin Drop = 3.2 feet Average Slope = 1.33% Runoff Coefficient (C) = 0.30 Time of Concentration (Tc) = 18.6 Min. (Figure 4) Intensity (I)2 = 1.9 in./hr. (Figure 5) Area (A) = .80 Acres Frequency Factor (Cf) = 1.00 Q2 = Cf CIA = (1.00) (.30) 0.9) (.80) = .46 cfs Q100 = 0.25) (0.30) (5.4) (.80) = 1.62 cfs 5 Table I Summary of Runoff Coefficients Area I (Retail) Use Building Parking & Sidewalk Landscaping Total Area II (Restaurant) Use Building Sidewalk Parking Landscaping Total Runoff Area Coefficient 17,500 Sq. Ft. .95 50,600 Sq. Ft. .95 17,000 Sq. Ft. .20 85,100 Sq. Ft. .81 Runoff Area Coefficient 4,000 Sq. Ft. .95 2,150 Sq. Ft. .95 15,775 Sq. Ft. .95 12,375 Sq. Ft. .20 34,300 Sq. Ft. .68 Area III (Convenience Store) Runoff Use Area Coefficient Building 3,000 Sq. Ft. .95 Parking & Sidewalk 22,225 Sq. Ft. .95 Landscaping 9,675 Sq. Ft. .20 Total 34,900 Sq. Ft. .74 Area IV (Retail) Runoff Use Area Coefficient Building I1,000 Sq. Ft. .95 Parking & Sidewalk 5,000 Sq. Ft. .95 Landscaping 7,000 Sq. Ft. ..20 Total 23,000 Sq. Ft. .72 6 Table I (continued) Area V (Office) Use Building Sidewalk Parking Landscaping Total Area 5,000 Sq. Ft. 1,475 Sq. Ft. 12,090 Sq. Ft. 12,535 Sq. Ft. 31,100 Sq. Ft. Area VI (Restaurant b Retail) Use Building Sidewalk Parking & Street Landscaping Total Total Drainage Area Area 11,000 Sq. Ft. 4,080 Sq. Ft. 7,540 Sq. Ft. 8,030 Sq. Ft. 30,650 Sq. Ft. 239,050 = 5.48 Acres Impervious C = .95 = 172,435 72.0% Grassed C = .20 = 66,615 28.0% Total Weighted C = 0.74 Combined Area Block I 3.29 0.56 Area I 1.95 0.81 Total 5.24 0.65 Runoff Coefficient .95 .95 .95 .20 ME Runoff Coefficient .95 .95 .95 .20 .75 7 Developed Conditions Area III Basin Length = 290 feet Time of Concentration = 10 + L = 10 + 290 = 12.4 Min. 120 120 Weighted Runoff Coefficient (C) = 0.70 (See Table I) Time of Concentration (Tc) = 12.4 Min. Intensity (I100) = 6.6 in./hr. (See Figure 5) Area (A) _ .80 Acres Frequency Factor (Cf) = 1.25 Q2 = (1.00) (.70) (2.1) (.86) = 1.18 cfs Q100 = Cf CIA = 0.25) (:70) (6.6) (.80) = 4.62 cfs Area III (Convenience Store) flows will be directed to the Northeast corner of the site where they will be detained. An inlet structure #C-I and outlet pipe will release historic flows into the 36" storm sewer along Shields. The detention requirements for this site are as follows: Detention Requirements a TOTAL HISTORICAL REQUIRED TIME TIME I100 (CF)(C)(A) Q100 DISCHARGE Q2 DISCHARGE DETENTION (MIN) (SEC) (cfs) (Cu.Ft.) (cfs) (Cu. Ft.) (Cu. Ft.) 20 1,200 5.2 .70 3.6 4,368 .46 552 3,816 25 1,500 4.6 .70 3.2 4,830 .46 690 4,140 30 1,800 4.2 .70 2.9 5,292 .46 828 4,464 35 2,100 3.8 .70 2.6 5,586 .46 966 4,620 40 2,400 3.5 .70 2.5 5,880 .46 1,104 4,416 45 2,700 3.2 .70 2.2 6,048 .46 1,242 4,806 50 3,000 3.0 .70 2.1 6,,300 .46 1,380 4,920 55 3,300 2.8 .70 2.0 6,468 .46 1,518 4,950* 60 3,600 2.6 .70 1.8 6,552 .46 1,656 4,896 65 3,900 2.45 .70 1.7 6,689 .46 1,794 4,895 70 4,200 2.3 .80 1.6 6,762 .46 1,932 4,830 * Approximately 4,950 cubic feet (.I1 Ac-Ft) of detention will be required. This Volume is provided as shown on the grading plan. 0 Area II, IV, V and Area VI flows will be refined as site plans are submitted for those areas. These areas flow into the storm sewer as shown in Figure 3, Page 14. Detention for Combined Basins is as follows: Block I 6 Area I Basin Length = 290 feet Overland Flow 80' 2% Slope 11.0 Min. Gutter Flow 260' .8% Slope 1.0 Min. Pipe Flow 670' .8% Slope 3.0 Min. Total 15.0 Min. Weighted Runoff Coefficient (C) = 0.65 (See Table I) Time of Concentration (Tc) = 15.0 Min. Intensity (I100) = 6.0 in./hr. Area (A) = 5.24 Acres Frequency Factor (Cf) = 1.25 Q100 = Cf CIA = (1.25) (.65) (5.24) (6.0) = 25.55 cfs Q2 = (1.00) (.65) (5.24) (2.1) = 7.15 cfs v] Detention Requirements TIME (MIN) TIME (SEC) I100 (CF)(C)(A) Q100 (cfs) TOTAL DISCHARGE (Cu.Ft.) HISTORICAL Q2 DISCHARGE (cfs) (Cu. Ft.) REQUIRED DETENTION (Cu. Ft.) 20 1,200 5.2 4.26 22.2 26,582 2.04 2,448 24,134 25 1,500 4.6 4.26 19.6 29,394 2.04 3,060 26,334 30 1,800 4.2 4.26 17.9 32,206 2.04 3,672 28,534 35 2,100 3.8 4.26 16.2 33,995 2.04 4,284 29,711 40 2,400 3.5 4.26 14.9 35,784 2.04 4,896 30,888 45 2,700 3.2 4.26 13.6 36,806 2.04 5,508 31,298 50 3,000 3.0 4.26 12.8 38,340 2.04 6,120 32,220 55 3,300 2.8 4.26 11.9 39,362 2.04 6,732 32,630 60 3,600 2.6 4.26 11.1 39,874 2.04 7,344 32,530* 65 3,900 2.45 4.26 10.4 40,704 2.04 7,956 32,748 70 4,200 2.3 4.26 9.8 41,152 2.04 8,568 32,584 75 4,500 2.15 4.26 9.2 41,216 2.04 9,180 32,036 80 4,800 2.05 4.26 8.7 41,760 2.04 9,792 31,968 * Approximately 32,748 cubic feet (.75 Ac-Ft) of detention will be required. This detention will be provided in Pond "A". .78 acre-feet is available there. Shields Storm Sewer b It is proposed that a 36" storm sewer be provided along the west side of Shields from Horsetooth - North approximately 1,300'. A portion of this storm sewer was constructed under Horsetooth and a 42" section was placed under Shields just South of Casa Grande. It is proposed that this project will complete the 36" pipe between those two sections. A review of the Foothills Basin (Basin G) Drainage Master Plan, indicates that, in its existing condition, approximately 180 cfs would run along. the west side of Shields Street. (Page 14) (Table 3) After completing an analysis of the area, Resource Consultants, Inc. recommended a Storm Water Management Alternative for this area which involved the construction of three detention areas 017, #18, #19) and the storm sewer along Shields as shown in Figure 8, page 28 of the Master Plan. With the construction of the three detention areas and with fully developed conditions, 100 year flows of 46 cfs could be expected along Shields (Table 5, page 30). The design of the 36" RCP along Shields will adequately provide the conveyance for these flows. Jul One of the three detention areas (Pond 17) is to be located in Section 27. The Master Plan in Table 6 on page 36 identifies the need for 3.5 acre feet of detention and maximum outflow of 11 cfs. The Horsetooth Commons PUD is providing 2.69 acre feet of detention and limiting outflows to 3.9 cfs as discussed in the preliminary drainage calculations submitted December 3, 1986 for the Williamsburg PUD. Any additional detention would be provided by the vacant ground to the west of the Horsetooth PUD. Figure 5 shows that a 36" concrete pipe flowing full will convey 47 cfs — more than the 46 cfs called for in the Foothills Basin Master Plan. L • C a 1 d •.a --Reach Figure 2 Scale I in feet I 1000 500 0 1200 7 m= 13 Legend: major drainageway pipe only = channel only existing detention area Proposed detention area see Table 6 1 drainage concentration p '> R I see Table 51 a THE MARKET AT HORSETOOTH COMMONS P.U.D. Ic u 0 0 L N N Y+ O x �1%6N'% . �� Shields TRACT 'D` Drainage Basins Drainage Improvements w� 0 4� ti Q 0 Proposed 36" Storm Sewer' — Z—'Tn!!n� z w n a• 0 0 C a RS \\\\\\\N Figure 3 No Text iiiiGGiiGi7iiii7�7iii 1.500 2.400 0.00 4 0.5 0.4 2.000 0.3 0.005 1,000 1,500 0.6 0.006 0.2 800 0.007 600 1'000 0.000 O'T 500 Soo 0.009 0.1 0.01 0.8 0.09 400 600 500 0 g 0.06 500 0.05 400 I.0 0.04 200 300 20 0.03 0.02 200 IS 0.02 100 0.03 _ 80 10 c 1.5 1 0.80% 100 9 u 0.04 0.008 36" Storm Sewer 60 96 8 along Shields 50 6O a 0.10 0.05 0.006 84 7 O,pB 0.005 40 Q = 47 cfs 60 72 6 = c 0.06 2 0.004 50 a 0.050.or 0.34% 30 60 S •` 0.040.08 0.003 0 4 w S4 V - 0.03 °-09 20 ., 48 4 Z o O. 0.002 n = 24 cfs 0 42 36" Diameter Concrete °'02 / o� I 36 3 n = 0.011 ° 3 v jtOiiO Sewer 20 n - •0 33 Q. SV �' c 0.010 " 0.001 c from Block I 10 e 30 %y o.000e - o T 0006 E 8 24 0 0.006 02 o 0.0006 e c ° N 0.0005 0 6 10 u 21 c 0 4 e < 0.0004 o 0 5 p 6 0 0. 16 0.3 = - c c u o 0.0003 6 4 6 0 15 5 O 5 0.4 0.0002 0 3 v 12 V 4 0.5 10 6 2 3 o.0001 0.6 V=6.8 fps e 0.00008 o. 2 Q9 0.00006 1.0 6 1.0 8 O.000OS = 0.00004 0.8 g 0.00003 I.0 v 0.6 4 ' 10 0.3 o.0 c 0.00002 0.4 0.6 e 2 G 0.3 O.S 0.00001 0.4 �. 3 0.000008 0.2 0.3 IS 0.000006 4 0.000005 0.000004 0.13 0.2 5 IB Fig.6•. Nomograph for flow in round pipe-Manning's formula 17 a �rch��,d �naQ 1.1 Ca iWk �'�chmai rDnve IS a Ce! lchIr ffa. nw ifrt Fe fbvlrk . On -Fv//Ow'r,L Grptg4ojr s = . 610 9 _ .0533 1a �,y = GS6)GZ (0/07�)i.sg�� 4A= C S6) CrZ) (. IO�Y)C.1SlS� Q� = G• 9 c�S c f s Q4 y g6(,o�b) qAY ` G 9c{s _ 2J cF, = 'f6cFs Q T= 6?A F idticflda Fa0h, (f) F)gwf q-Z AefF Of AU spree f � as qB = Yo = 133 - 0/6 s = .0/09 qD (G, S0) �. A'0`I ! �. 33 e/6l qa= q,SC6 = ly.l cfs 113 crs fill ov4yc i Rrcj�oOw J Qfrr;� Flows t01P.83 - 0f41 o6k flaws f(ao, 45M lb QUA %z of f Q%� µt fives a/{ off fe xPHa cfs Gt�-e Q3 . , fdllou�S , Cq _ f cfA A Q4a 7 Irf I z 3.9 fps ago = I•zS(7,1) Cs3) ASS Qrac, = y 6 c f 5 950.8 __ 2-Y3 Src 3.5 T IQ l Q = 9,6 cf5 t tS c� = s �P� ow 7'/d Jf• 3 ` gllowoif e It no*,s It 4ew Y4 �l of 14 cuib. 56A SrdP Z-a„ y 5 : /,Iq 11(7 9 f 33. 73 — 0 41 = 972, 73 T( = y o IIS.P a,0 A4 05 ZS ( r7z. 73) , SO i%ios N 3 SGO 7/ I�Oise flog f(e. R"4'.I as �dQn II P,el q to lkisQt) fig strut 1�elf Tc = .1 MIA, Use 1010 All . cf--lZ�— A (Z5) (9Sb83SGo` (ov C = 9S = Y 1 nli 7,Ycfs )14 / all s +ftt f odes lvril cf5 y.7 cf s 15 I'fx 4 t 3c cl�) ca�lh 14 ifo Sf&(A rl, of Ricie4i 1$00 . i 4 � VIa��I/ Secfla, Graz �.) n 040 213 5'�1 ti- n 1,y9 (,97 ?h� (, oolf .060 v= "IlkM/ •37,1 = a,3 Sys Curve Rvolivts = So' LIP = 16.50 ��eF 16 sy Faft R I r Z.lP � ll•So = .97 Q = lYl (.,1779)(.0i70)&) Th loo y4ovAWOMOM fkll fro-, B jori l a? a /olKM+a�t� t C�aKRll to kqv P,�o�•4 �� y �7 c s 7�is � ��d� porn � J Cp�l ac/i 1-0 FossJGSP TldWS. Q¢p 4 flow w171 �P G7j�/ax��i CONSTRUCTION HOES: CEREBRAL MOWS: CD Existing storm slower ans rulWle ; Install 5' thruster standard ma overru 1. 1M City of fort Collins shall t be responsible for the maintenance astie9 36- R.CAdlie A' V.V.L. Site Store sner into new 04 stars drainage facilities located on private property. morale. See Sheet 3 of 3 for installation details. z. Temporary @rollol control weal ill be required during Q Standard storm setwer NO; gee storm .n or Mmarofile on Sheet 3 of 3 for construction. Temporary yeales r be uud around the Pl coed inlet •anlwle rimand invert information. AltoSee Standard Manhole detail or to parking lot p Refer to the Myoale placement detail on Sheet 3 of 3. provided on sheet 3 of 3. Refep to Draft cane of City of Feet Collins Erasion Control Reference Manual for additional erosion control Q Proposed Storm Area Inlet; See storm sa profile on Sheet 3 of 3 n alternatives and oonendations. rim and invert wformut Also see Sleet 3 op 3 for area Inlet detail. 3. The ParPin9 lot limits which will be utilized for detention np mall be located within a ceeasement No drainage ea ment Ms base Q Pr,POW Orir vnar d each; Remoe eusting vertical curd and gutter dedicated by the Plat of Horsetail Cast P.L.D.Therefore a Necessaryits to j,,Adl rim dvtu rner apprWIN. See Sheet 3 of 3 for drainage easement will be dedicated by Separate instrument to satisfy Driveway approach detailsfor vertical Curd and Batten the w9uiTmI of the City of Fort Calltns. IM1 EI/0 COR 9n c u r III occur SEC E1 (7` Proposed stop si : Install according to the r shim% of the 1 4. Cal mashing .ill oo •nhio the showrogual building limits. A TIN, R69N 'Manual of uniform Traffic Control Devices' Old the City of Fort 11 moor amain• .at be rovided whim mill be tied direcity to the Collins Trafna Department. ! p4 sanitary Power system a [carding to local codes. wastewater is" ca mashing operations all at be allowed within the City of Fart Collin; %ara,�, storm sner ay,trm — — , WAA RODN �_HW RICH8 ANMONDRDRIVE e �11 R=I6.00 RICHMOND DRIVE 4 = 89.44' 16' —� EXIST .Al malt El -xYWRANT I 4 2506I J� FE EC. uLi _ 1__'IS T-15.93' SB —+ ll—_�1STOB'- rani .I px' f 1j. C =z2 sB' maw - _- - ae\\ C8=S44°52'2 WE -. _ a° I- II Q it 1 ExBi S \\r _ or yEL C 1a SEW SERVICE I "SExVICE VAIN i X1 BOp is STa p9 ma Y OEICE/RETAIL III III FF�W'S0 �v YI EMER6ENCV SPILLWAY 3 P6dCE5 11 AdA, a NAIEP MUE£E/CEEO J0.2Ill AY la a.� -CWB ICI f METER III, P VL ES V f III V r �\`� O I TO ESCAPE An I PROPOSED "VIER TAG IR�— °SfINIEE I51 i III • \.m J SIAOa2 CO 01 y ill „1 PATCH Racx PER TYPICAL 1 n 1 f FRENCH DETAIL R p, ill Fall I INo Auv PAY - `�.' X 1 or sec*iaHDz]sE v9 lilli 'o,A ABANDON EXIST TAPS t / -.EV' SERVICE 4T WREPYAIH I I I I 9 �o — At � ;II Ina. iII J r r, - D o I 1^I I IY it r LU 1 0 f Ib a sp 11�I W A 1I h Al w It 0 '11 O e 6 Du:Do9n w 0 1 C 7l �� a�` j ; — .,015PLAY - 1It ED 1 `? W " Ill i No I � I' dip J 14 0 it Sells s... CE ; 1 �� 1 u p 1 11 1 we, T m — All W STA 0 fSTA 0 f 23 bF! "; 0 0 It w1 it F IIm A=25'20'z]" lit 111 lTOS R • 114.00 MN six D.co li III III 1 m Fe BOSO RETAIL/ HOWROOAs II A• 50.42 -- __ I' deal � L m 1 ,. 1 d I R �'' ' I I T=25.63 —i I I n 0. l/ i s L ow M ji t �I CB-NI2°4D'14"E II I Ili A/I at i e� IF 1 �i II Ali 1.-� �� �/ mplOs i� H6I 3 It It \ 1 � ��I P 3 —FAA, it I'llUtz N89.45 30"W ]50] 1I �1t - _ - Iit I II /21 �H``AA LOT I R 2 m o5 5]" z` i `x `\ ; C III � O L OF 1 _. �a_��> .n•` t ll ` VL N o A= 06 i T= 2 93' 11 C,4 1,67' DETENTION POND DATA sl CB= ]]°I2'30"W LEGEND wnaar: 5 E CUR Inlet rim elevation - 7B.40 Idemhtlon polo III Point, sec.¢] EXISTING PROPOSED High water Is,. Prior to overflow • 30.20 at North corner of parxxng lit. TIN, R69N' - - i..L H..imile depth in Parking area - 1.50' at initial werllw -.. -- .. Detention Values available - 4650 cu is feet Detention volume r...... I - 4E2B mamma rest (Cumulative runuff method) CITY OF FORT COLLBNSACOLORADO UTILITY PLAN APPROVAL MASTER UTILITY PLAN GRADING &DRAINAGE PLAN APPROVED: All, .mn,.a. sue • .I . CHECKED 9Y: "I mA.eAurmn u.,ur. PA.s C/dCKEO BY me 510" "A,s. mu.. DAra CHECKED BY'. ANA111 All 1OVEALI'll 'All REVISIONS Date DULY 1990 Cal JM/BWS CLIENT TITLE MASTER UTILITY PLAN. GRADING A DRAINAGE PLAN MOACT No. SHEET NO. xo.OF 11o so"Plian SHEAR ENGINEERING CORPORATION b DU ... phen FINISH Boon KING A ASSOC. CM ked BWS KENT GOODMAN FORT COLLINS, COLORADO LOT 2, THE MARKET AT HORSETOOTH COMMONS 1200-1-90 Data — g oarnlDnon BcaM 1-=30' Approved B9 PHONE: (303) 226-5334 FORT COLLINS, COLORADO 2 3