Loading...
HomeMy WebLinkAboutDrainage Reports - 01/01/1986FINAL DRAINAGE REPORT f3T1 THE JETTY P.U.D. AT THE LANDINGS FORT COLLINS, COLORADO PREPARED FOR: OSPREY, INC. JANUARY, 1986 PREPARED BY: SHEAR ENGINEERING CORPORATION 4431 HOLLYHOCK FORT COLLINS, COLORADO 80526 PHONE (303) 226-5334 .wf TABLE OF CONTENTS A. Title Page Table of Contents Introduction Summary References B. Drainage Calculations C. Appendix Rainfall Intensity Duration Curve Street Capacity Analysis for Interior Streets Nomograph for Flow in Triangular Gutters Nomograph for Capacity of Curb Opening Inlets Capacity of Grated Inlet in Sump Chart Existing 36" RCP Storm Sewer Profile Supplemental Drainage Report for The Jetty at The Landings P.U.D. by Cornell Consulting Company. INTRODUCTION: The Jetty P.U.D. at The Landings is a proposed 12.15 acre professional offices/single family residential development. The property is located in the West 1/2 of Section 36, T 7 N, R 69 W of the 6th P.M. in the City of Fort Collins. It is bounded by Boardwalk Drive, Landings Drive, and the Larimer County No. 2 ditch. The Jetty is included in the Harmony Reservoir Drainage Basin as defined by Cornell Consulting Company, 1980. It was originally planned for Condominiums in 1980 and was a part of the overall Harmony Reservoir Drainage Basin Report by Cornell Consulting Company. This report will analyze the effects of a 100 year storm on the property for the new proposed professional offices/residential use. An overall drainage plan for the Jetty will be suggested for controlling the antici- pated storm runoff on the property. This drainage plan will comply with the Harmony Reservoir Drainage Basin plan, with minor modifications. SUMMARY: Because the Harmony Reservoir Drainage Basin plan made use of Harmony Reservoir as a detention facility for 100 year storm events for all properties within the basin, no onsite detention will be required on the Jetty property for the residential portion. The storm sewer de- signed for the portion of the property planned for future professional offices, Basin I, was sized for the 10 year storm event. Detention will therefore be required on that portion of the property when developed, to store all runoff above the 10 year storm flow., Historically, runoff traveled to, and was intercepted by, the Larimer County No. 2 ditch. The Larimer County No. 2 Ditch Company has indicated that they prefer to see the drainage plan for The Jetty comply with the Harmony Reservoir Drainage Basin plan and not allow runoff, especially from the 100 year storm event, to enter the ditch and be allowed to travel in the ditch downstream, across Boardwalk Drive to the improved. portion of the ditch which was designed as a part of the Heart Special Improvement District.. The ditch company has also indicated that they prefer that runoff not be diverted by way of the proposed ditch mainten- ance access way. Because of these two restrictions by the Ditch Company and because Basin III cannot be graded to direct runoff to Jetty Drive, without unreasonable, uneconomic filling of the property, Basin III will direct runoff into the ditch and be diverted from the ditch to the Harmony Reservoir Drainage Basin system by way of a concrete diversion structure constructed in the ditch. The concrete diversion structure will be de- signed to facilitate not only diversion of 100 year storm flows from Drainage Basins IIIA, IIIB, and IIIC, but will also facilitate diversion requirements of The Larimer County No. 2 ditch. Basins II and IV channel 100% of the 100 year storm flows into a storm sewer system which connects to the existing 36" RCP east of The Jetty and is part of the Harmony Reservoir Drainage Basin Plan. The storm sewer was sized to facilitate 100 year storm flows so that these flows cannot enter the Larimer County No. 2 ditch. Page 2 Basin V is the only basin from which flows into the ditch will be carried across Boradwalk Drive. The 100 year storm contribution to the ditch from Basin V which will not be contained in The Harmony Reservoir Drainage Basin is approximately 1.85 cfs. Street capacities, storm drainage structures, storm sewers, etc, are analyzed in the Calculations section of this report. Please refer to the grading and drainage plan in the back of, and made a part of this report. REFERENCES: Storm Drainage Design Criteria and Construction Standards, City of Fort Collins, Colorado, May, 1984. Supplemental Storm Drainage Report for The Jetty At The Landings P.U.D., . Cornell Consulting Company, February, 1980. Final Drainage Report for Heart Special Improvement District, Engineering Professionals Inc., Revision Date, January, 1984. Harmony Reservoir Drainage Basin plan, sheet 10 of 11 of The Jetty Condo- miniums, filing 1, at the Jetty P.U.D. Utility plans, Cornell Consulting Company, February, 1980. DRAINAGE CALCULATIONS BASIN IA TO CONCENTRATION POINT I. To determine storm sewer size for future professional offices on Tract A. Area = 3.32 acres C = 0.85 (future professional offices). Longest travel distance = 700' QElevation = 43-29 = 14� Average slope = 2.0% Tc10 = 1.87 [1.10 - 0.85 (1.0) ] (700)1/2 = 9.8 minutes (2.0)1/3 Ii0 = 4.40 in / hour. Q10 = 0.85 (4.40) (3.32). (1.0) = 12.4 cfs. Use 24" diameter RCP @ 0.40% Check capacity Q = 1.49 AR 2/3 S 1/2 n 1.49 (3.14) (0.50) 2/3 (.004) 1/2 .013 . (use 10 minutes) = 14_3 cfs i 12.4 cfs OK Use 24" 0 RCP @ 0.40% BASIN IIA TO CONCENTRATION POINT IIA. To determine street capacity of Jetty Drive (Northwest). Area = .1.20 acres C = 0.50 (residential) Longest travel distance = 755' Q Elevation = 11' Average slope = 1.45% Tc2 = 1.87 [1.10 - 0.50 (1.0)] (755)1/? = 27.2 minutes (1.45) 1/3 Tc100 = 1.87 [1.10-0.50 (1.25)] (755)1/2 = 21.6 minutes (1.45) 1/3 12 = 1.55 in / hour i100 = 5.0 in / hour Q2 = 0.50 (1.55) (1.20) (1.0) = 0.90 cfs Q100 = 0.50 (5.0) (1.20) (1.25) = 3.8 cfs Allowable 1/2 street capacity = 4.2 cfs >3.80 cfs Street capacity of Jetty Drive OK. BASIN IIA AND II B TO CONCENTRATION POINT IIB. To determine inlet size required at intersection of Jetty Drive and private access drive. Area = 2.48 acres C = 0.50 (residential) Longest travel distance = 755' DElevation = 11' Average slope = 1.45% Tc100 = 21.6 minutes (see basin IIA to C.P. IIA) i100 5.0 in / hour Q100 = •50 (5.0)(2.48) (1.25) = 3.8 cfs Apply reduction factor,3.8/.85 = 4.47 cfs. Refer to figure 5-2 for curb inlet size determination. Height of inlet opening - 6" Depth of water in street channel - 0.27' (see figure 4-1) Yo/h = 0.27/0.50 = 0.54 Capacity per foot = 0.44 cfs/ft Inlet length required - 4.47/0.44 = 10.16 feet Use 10' type R curb inlet. BASINS I AND II TO CONCENTRATION POINT IIC. To determine storm sewer required out of type R inlet. Q from Basin II for 100 year storm = 3.8 cfs Q from Basin I for 10 year storm = 12.4 cfs Storm sewer to be designed to carry 19.9 cfs. Use 24" diameter RCP @ 1.23% Check capacity. Q = 1.49 A R 2/3 S 1/2 n 1.49 (3.14) (.50) 2/3 (.0123) 1/2 .013 = 25.1 cfs > 19.9 cfs . OK Use 24" 0 RCP @ 1.23% BASIN IIIC TO CONCENTRATION POINT IIIC. To determine actual contribution to ditch from the Jetty development. Area = 2.69 acres. C = 0.50 (residential). Longest travel distance = 1,380 DElevation = 43-30 = 13' Average slope = 0.94% Tc100 = 1.87 [1.10-.50 (1.25)] (1380)1/2 = 33.70 minutes (.94) 1/3 i100 = 3.90 in / hour Q100 = 0.50 (3.90) (2.69) (1.25) = 6.5 cfs BASINS IIIA, IIIB, IIIC TO CONCENTRATION POINT IIIC. To determine 100 year storm runoff to be diverted from ditch to the Harmony drainage basin 36" RCP storm sewer. Area = 3.67 acres. C = 0.50 (residential) Longest travel distance = 1,920' AElevation = 48-30 = 18� Average slope = 0.94% Tc100 = 1.87 [1.10 - .50 (1.25)] (1920) 1/2 = 39.7 minutes (0.94) 1/3 i100 = 3.5 in / hour 4100 = .50 (3.5) (3.67) (1.25) = 8.0 cfs A structure will be designed to divert 8 cfs from the ditch to the 36" 0 RCP storm sewer. This structure will be designed to meet Larimer County No. 2 Ditch Company specifications and requirements. BASIN IV TO CONCENTRATION POINT IV. To determine area inlet opening required. Area = 1.32 acres C = 0.50 (residential) Longest travel distance = 273' 46Elevation = 3' Average slope = 1.10% Tc100 = 1.87 [1.10 - 0.50 (1.25)] (273) 1/2 = 14.2 minutes (1.10) 1/3 i100 = 6.0 in / hour Q100 = 0.50 (6.0) (1.32) (1.25) = 5 cfs Refer to figure 5-3 for area inlet opening determination. Ponding depth over inlet - 0.35' (see figure 4-1). Flow into inlet / square foot of open area = 3.0 cfs / square foot. Open area required = 5/3 = 1.67 square feet. Use Neenah R-3570 square inlet frame and grate - opening = 1.63 t S.F. BASIN V TO CONCENTRATION POINT V.' To determine actual contribution to ditch. Area = 0.80 acres C = 0.50 (residential) Longest travel distance = 500' AElevation = 23.23 - 22.37 = 0.86 Average slope = 0.17% Tc100 = 1.87 [1.10 - 0.50 (1.25)] (500)1/2 = 36 minutes (.17) 1/3 i100 = 3.7 in / hour Q100 = 0.50 (3.7) (0.80) (1.25) = 1.85 cfs. BASIN VI TO CONCENTRATION POINT VI. To determine contribution to Boardwalk Drive adjacent to The Jetty. Area = 0.87 acre C = 0.85 (ROW only) Longest travel distance = 1,050' AElevation = 13' Average slope = 1.24% Tc2 = 1.87 [1.10 - 0.85 (1.0)] (1050)1/2 = 14.1 minutes (1.24) 1/3 Tc100 = 1.87 [1.10 - 0.85 (1.25)] (1050)1/2 = 2.1 (use 10 minutes) (1.24) 1/3 12 = 2.15 in / hour i100 = 7.0 in / hour Q2 = 0.85 (2.15) (0.87) (1.0) - 1.6 cfs Q100 = 0.85 (7.0) (0.87) (1.25) = 6.5 cfs APPENDIX No Text A�tl!d7j=til4i aita�ysis 4- Y. n= 0.016 Me �= s = %� • /a6� Q6 = DSO Kio.6e/.0✓ooe-Mvlo�l, */ lg eA - Qmruc = d4 9 = 5,3 10000 9000 0000 7000 6000 5000 4000 - 2000 ' 1000 900 Soo ; 700 IQ 600 1500 o 400 Q 300 200 I 100 90 6o 70 60 C10` 40 30 20 10 From BPR 2.0 ., I7 _ /euAT10NI 0 • 0.66 (A) m7 n t6 ROuo"n4im coa,"CNMt IM 411410411,11 .10 FORM"& APMoM1ArE To MATERIAL 1R motion OF GYAMR[G 1.0 116 ■taP4oW OF MOSS SLOP[ .00 REFERENCE- W 0 6 M10C9Ea166 ,W. .07 Met Me. Situation 1141 .60 06 �•,; .70 EXAMPLE Cott o•onto uM161 1J' ,Q6 too .60 art•. 0 0.06 To \ n . oll G/tt . 1800 N ILL.eo F; .04 i .60 ci 70 LL .H; o. • u so ILL. FIND, 0 • 2.0 @F6 -- .03 .40 to z Z Z ---- t-_ .02 .20 W : Z INSTRUCTIONS Q Cr- 0T W .01 a 1. COMRCCT 4/n RATIo •1l. 6L08'a ISI Q ,pe z ANo CDYMKGf O.SGHAMa 101 ..To = 0' Z .008 09PTH UI IM959 TWO LINES YutT U�/L ,Ol 4Q .007 (n .10 IMT44S4CT AT TY4M.MG LINE FDA V r `\\,,.•i •� W COMPL919 SOLUTION Q .01 1i V .006 ^ aWa .06 4.004 {MALLOW 1 t W 005 W .07 vpuEO cxAMra/ O Q AS 6H0.4 U:a NOMOGRA " .004 .06 WLTx4- W Cr I n. O .os 6 TO ottlOnnt • r, .003 m a:cx•4u o, 1R T. ' ' N Cr_ .04 POOTIor or MATING WIDTH x: olillNlRl Cal14 , FOR TOTAL DISCHARGE IY %bag /action 0 IHto u:t NOMOS•APH to 04114N1Nt 04 14 SECb010 • FOR cap?" r' F-Q) 4 10 0(1[RYIMI OHCHAR69 r� Nt GO•rOf.t( $ICf TOM • � FOLLOW •R/t4YCTIDM t f!T 10 o14,11 OISCMA444 .4 1-_t-,. a,J :action a At ASW4Ilo •441,•F1 Ogot" , 1 OmTA.n 0. FOR SLOPa RATIO Al AND DEPTH J. tHan 0, • 0. T OL .002 .001 Figure 4-1 NONOGRAPH FOR FLOW IN TRIANGULAR GUTTERS (From U.S. Dept. of Commerce, Bureau of Public Roads, 1965) U ' .03 � Q x a .02 W 0 .01 MAY 1984 ' 4-3 DESIGN CRITERIA 1.0 .9 .8 r7 .6 .5 F- W u- .4 V z z .3 W 0- 0 U. 0 .25 x c� w x .2 .15 12 II 10 8 10 6 w 9 004 8 a 3 ���� z vi 2 T 0� - � z „ 10 z Ezomp1,eiPart a . _ J 8- z -• w 5.5 cr a - v) V .6 0 W =0A4Wiq.O 5 z z .4 = - W � 4.5 z 0 •3 - 4 t 0 .2 0 'V^ V L z z z r 3.5 w w 0- J 0 1 w U- 0 .08 o �- 3 0 .06 x c� U. z w o: .04 CC 2.5 = o_ .03 a a .02 0 a x 2 a F. a w 01 0 L U. 0 0 Yo a 1.5 "' i --- -- - -- -- x I J- 1.2 5 4 3 2 1.5 1.0 .9 .8 .T .6 ``�� Yv A s o.s4 5 .4 .3 .25 .2 .15 W Figure 5-2 NOMOGRPAH FOR CAPACITY OF CURB OPENING INLETS IN SUMPS, DEPRESSION DEPTH 2" . Adapted from Bureau of Public Roads Nomograph MAY 1984 5-10 DESIGN CRITERIA 0.8 0.7 w 0.6 F- w Z 0.5 w > 0.4 0 a 0.3 w 0 i 0.2 0 z 0 a 0.1 EXAMPLE 0 1 2 3 4 FLOW INTO INLET PER SO. FT. OF.OPEN AREA (CFS/FT2) Figure 5-3 CAPACITY OF GRATED INLET IN SUMP (From: Wright -McLaughlin Engineers, 1969) 5 MAY 1984 5-11 DESIGN CRITERIA No Text Kam : R )3 a82-66w CORNE11 CONSU�TINCI COMPANY po Ix)a 616 I()Rr cdlws, u�loando t10'iL2 f� ( ) = MWtVf WENT/ENgiKER1Nq . February 25, 1980 Mr. Bob Smith Storm Drainage Engineer City of Fort Collins P.O. Box 580 Fort Collins, Colorado 80522 Dear Bob: We are pleased to .submit this supplemental storm drainage report for The Jetty at The Landings PUD. Five copies of the utility plans are submitted contemporaneously. The hydrologic calculations represented here were compiled by Ed Goodman, EIT, and myself, Bill Blackwell, EIT. Our work has been reviewed by Harry A. Cornell, P.E. engineer in charge. "The design for storm drainage at The Jetty and for the Harmony Reservoir basin is, to the best of our knowledge, in compliance with the Preliminary Draft Storm Drainage Design Criteria for the City of Fort Collins dated April, 1979• We hope this report facilitates your review of storm drainage at The Jetty. Sincerely, CORNELL CONSULTING COMPANY .= ':Bill B l a ckwe l l .;Senior Design Engineer n�. Harry A. Cornell, P.E. ' °r President BB:HAC/fsr Enclosures ;:� . - . ._ z .;,. SCOPE The purpose of this report is to present the analysis and -;'.assumptions leading to the storm drainage design presented in FThe Jetty utility plans. Located in the west half of Section 36, '.Township 7 north, Range 69 west of the Sixth Principal Meridian, The Jetty Condominiums at The Landings PUD is a proposed multi- family development of approximately 18 acres. This report addresses both upstream and downstream basin .conditions at the site. It also presents the methods, assumptions and final results of our hydrologic analysis, culvert and storm .:. _sewer design, and street flow calculations. Construction drawings relating to storm drainage are presented on the sheets indicated below: The Jetty Condominiums at The Landings PUD Utility Plans Sheet 4/9 - Overall Grading and Drainage Plan Sheet 7/9 - Parking Plan and Details Sheet 8/9 - Storm Sewer Plan.'and Profile' Storm Drainage, Irri ation Culverts and Bridges at The Landings approved 10/5/79 Sheet 2/3 - Culvert Crossing C, D BASIN ANALYSIS The Jetty is located in the unnamed basin between Mail Creek basin and Fox Meadows basin (Basin H). Storm water from The Jetty is detained in Harmony Reservoir prior to entering the basin thalweg. The main flow through the natural low point is analyzed ". in "Master Storm Drainage Report for The Landings PUD" January, 1979 and "The Pier Condominiums Drainage Report" September 1979, both of which were prepared by this office. Therefore this report will ' ;be limited to the Harmony Reservoir sub -basin. Historically only 30 acres of irrigated farm land contributed X", runoff to Harmony Reservoir. Present plans call for nearly 80 acres of RP -zoned land discharging into the reservoir. This land consists of single-family and multi -family units, 5 acres of park land and the reservoir surface itself. The reservoir's large surface area allows it to accept this runoff. Refer to Sheet 1/1 "Harmony Reservoir Basin 1980" in the *> appendix of this report for, sub -basin layout. The basin divisions shown are based on proposed grading and drainage improvements for the individual projects. :•+,'•,•• T In their present undeveloped state upstream lands such as I ¢ . +�, :. '°"'• South College Properties do not contribute storm runoff to the system. These discharge into Larimer County Canal No. 2. Anticipating potential future contributions of unknown size, the storm sewer under this irrigation ditch has been oversized by 47 cfs. The effects of lands between Harmony Reservoir and The Jetty are detailed in the == drawing referenced above. -2- v METHODS AND ASSUMPTIONS All storm flows for the Harmony basin were calculated using the Rational method. The overland flow time of concentration formula given in the Storm Drainage Design Criteria was used in every case with the slope and basin length based on proposed grading contours. The runoff to rainfall coefficient was applied by zoning only and not adjusted to dwelling density. The coefficient used was 0.5 for the RP zone. Frequency coefficuents are 1.0 for the 2-year storm and 1.25 for the 100-year event. Due to the slow release from Harmony Reservoir, the detention volume was set as the total runoff from a 3-hour, 100-year storm. Storm sewer capacity is calculated using Manning's equation under full flowing conditions with n = 0.011. The culverts under Westshore and Boardwalk Drives were sized using the charts in HEC-5 for circular pipe with bevelled ring inlet to approximate the standard transition inlet. Special note is given here to the storm sewer under Landings Drive. See Sheet 8/9 of the utility plans. A 12-inch pipe is specified due .to elevation restrictions of crossing under the street flow line and daylighting into a 0.4% open channel. Street flow calculations were checked only at the point of the largest street flow concentration. Subbasins D-1, D-2, and D-3 all contribute to the cross -flow in Westshore Way. Allowable flow was calculated according to the methodology in Section 4.2b of the Design Criteria. Allowable flow was twice actual flow. Further checks were not deemed necessary as the case of D-1, D-2, and D-3 constitutes the worst condition. - 3- -4- t —CONCLUSIONS it is our opinion that the drainage construction plans presented in "The Jetty Condominiums at The Landings PUD Utility Plans" provide adequate protection against major damage and loss of life during a major storm and dispose of minor storm flows quickly and safely. We have also allowed some flexibility in the acceptance of upstream storm runoff due to future development. -5^ PRELIMINARY OVERLOT GRADING III DRAINAGE PLAN ` THE LANDINGS (FIFTH FILING \ \ \ 3 2 \\ `�_ TRACT Tahle of Point Flows CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO- Legend: Basin Boundary Proposed Direction of Flow �9 Concentration Point ----___--- Existing Contour \ Proposed Contour \ Existing Storm Sewer Proposed Storm Sewer —�� Existing Bank \ 63 � N 5�r D \ seam. =so' \ 59 I drajVderagrd eyXLe 901%B3B53 7 a P Ip THE LANDINGS SECOND FILING ax \ et -\ TRACT A 66 j yr BASIN 4Iy, QT+iP in e4 V/ ' � � /AePf' Concentration Point 02 tee IA mm3.4 Is 0.10 2.7 Y = 1.0 %.Is 5.3 its !A - i9 - - XC - N o.W 3.1 Y - - yy Lb 6.5 TRACT B 3rd REPLAT LANDINGS FOURTH FILING to �1 IDA��� tsa,��� TRACT A BASIN Y BASIN IY 3T O' o ci5 AC. 2A \�� � � AC ---- ---- -04 BASIN IA �� �) 01 3 45 ACIt Future Commercial 0 ol Ridge Venture to / ✓_ Q h�1�Y1//��Y1// / m L) mumm _ o Q BASIN IIC 6�0. _\\ ` _ l `` RSIN II A --woo/ \ mvishmi,\Lestum \ \� Peterson NOTE: g A� 1 - �� Please refer to the Overall Utility Plan ob I I for proposed residential building layout. --__ PRELIMINARY OVERLOT GRADING & DRAINAGE PLAN !, SMEAR ENGINEERINLa eue+ru.+.+ r •`e- OSPREY, INC. 4431 Hollyhock (303)226-5334 Fort Collins, Colorado 80526 THE JETTY P.U.D. AT THE LANDINGS FORT COLLINS, GOLORADO. 9192 SSOMERSET P.U.D. 1 �I I I ! I I 1013 - 1 ' 1 The Jetty P.U.D. at the Landh ...--_.-_ REVI5101 u on' 1e. - Bv_ anb,lon Ban, Dec. 4,.1965 Drawn ""^ Field Book No.6 __ Checked _6W5-- scale I" = 50 Approved - BW5 - The Jetty PAID. at the LarMYISe THE JETTY P.U.D. AT THE LANDINGS CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. �\ THE LANDINGSIFIFTH FILINIII \ 1 -L -- 1 TRACT '1' TRACT A 66 I;aI i 65 Legend: \ Basin Boundary ' BA N Proposed Direction of Flow 03 $B Concentration Point Q ' I. - Existing Contour \ Proposed Contour j ---T Existing Storm Sewer ' !' Proposed Storm Sewer IIC -Q—� Existing Bank \ 63 THE LANDINGS SECOND FILING 3y6 r 62 �/ B SIN J,E A e A0s*�✓i // 1.20 AC/ BO Scale. , _ 50 - 59 \ \ 58 5] s5 TPACT'A' S -' � C Daniel Hershey drafudolgn xaax-Ys2 REVIS10 CAN vy lllriaw DIII B, B, o,Iall,0e."At" DP a 1Bf.T laa. ATER j 10.0.ION DNE0.elON STRUCTURE fA yc \ 4 o � 3rd REPLAT NAMPA` f �LANDINGS FOURTH FILING �� r s Hof T :T A \ BASIN II B \ Y B1 TO e. �� y�A, �— \ B SIN Y A D.C, o so / BASIN I +e D - / 11 Future Professional Offices L/ / �P ro y % 37 30, � 39 Silly �Ea BASIN B\ 0.30 C. \\'' IT VC \\ BASIN ]II A Table of Point Flows Concentration Point ZA ][ B 42 b10o 0.90 &ao — 3.60 19.90 II C RR $B _ $ C 5.0 MO &&.To 8 — 5.0 Y LES $ 1.6 Iw50 e 12 SOMERSET P.U.D. ll 11 I \ \e5tBm \ �<` ' " UTILIT:'eCOLLINSN PPROVAL d y \ ` O.btS AC. I - y Peterson ADo,an 'e 11da \ I INA AEP ^ "ROMER COUNTY CANAL No. 2 1�— J y- O;•uii l L -K ao `tea 64 unuyv PLAN APPROVAL eneuaa a oat, 441`6JUAKv 1`Inb , vCu Fleur Itmly Ho- 5 d, 5w5 S"Le .. _ ews OSPREY, INC. eROVEoT.nl. =y da,Nl N..v (� ene _ �'r„ Doll t-Iv_Yc Ch'Cn.d By pT[[ xY yr .. SHEAR ENGINEERING CORPORATION OVERLOT GRADING & DRAINAGE PLAN 4431 Hollyhock THE JETTY P.U.D. AT THE LANDINGS 1013- I Fort Collins. Colora0o 80526 (3031226-5334 FORT COLLINS, COLORADO 5 8 The Jetty P.U.D. at the Landings