Loading...
HomeMy WebLinkAboutDrainage Reports - 01/16/1992DRAINAGE INVESTIGATION A BUILDING REMODEL LOCATED AT 203 WEST MYRTLE STREET FORT COLLINS, COLORADO Prepared for EAST -WEST IMPORTS 203 WEST MYRTLE STREET FORT COLLINS, COLORADO 80521 APRIL 1991 Project No. HYD-052-90 (Revised May 1%4994 -Acutiw�r� STORMWA(i RECEIVED- JAN 15 1992 PREPARED BY: Messner Engineering Associates 150 East 29th Street, Suite 225 Loveland, Colorado 80538 Telephone: (303) 663-2221 Fin(:! An..roved Report { Date -J- Civil and Environmental Engineering Consultants Engineering Associates April 9, 1991 Project No. HYD-052-91 Mrs. Choko Oshima East -West Imports 203 West Myrtle Fort Collins, Colorado 80521 Dear Mrs. Oshima, The enclosed report represents the results of the drainage investigation performed for the proposed addition and remodeling of your building located at 203 West Myrtle Street in the City of Fort Collins, Larimer County, Colorado. This investigation was based upon the proposed site development and building construction plans; existing reports and plans for adjacent properties; on -site observations; and topographic information obtained on -site. The investigation was performed in accordance with the criteria established in the City of Fort Collin's "Storm Drainage Design Criteria and Construction Standards". Thank you for the opportunity to be of service to you. If you should have any questions, please feel free to contact this office. �� •° 'Y Dennis 53 �.�� MESSNE 'B �" �a Associates DRM/mkm (Revised per City of Fort Collins review comments dated May 14, 1991) Enclosures Civil and Environmental Engineering Consultants 150 E. 29th Street, Suite 225 Loveland, Colorado 80538 Telephone: (303) 663-2221 TABLE OF CONTENTS Letter of Transmittal Table of Contents Scope Site Description Existing Conditions Proposed Development Conclusions and Recommendations Letter Requesting Variance to On -site ii Detention Requirement (Added 4-26-91) EXHIBITS Vicinity Map Original Conditions Exhibit Existing Conditions Exhibit Proposed Construction Exhibit Calculations (Revised 5-16-91) Architectural Site Plan (Added 5-16-91) ii SCOPE The following report represents the results of a drainage investigation performed for a proposed remodel and addition to an existing structure located on the North 90 feet of the West 65 feet of Block 106 of Harrison's Addition to the City of Fort Collins, Larimer County, Colorado.The investigation was performed for East - West Imports. The purpose of this investigation is to determine the effects of the proposed development on the area's existing drainage conditions and to determine the improvements, if any, and the appropriate sizing for proposed improvements so that it may be incorporated with the construction of the project. The conclusions and recommendations presented in this report are based upon the proposed building construction and site redevelopment plans; grading and drainage construction plans and reports for existing adjacent facilities; on -site observations; and the available topographic information. The analysis was performed in accordance with the City of Fort Collins' "Storm Drainage Design Criteria and Construction Standards". SITE DESCRIPITION The property is located at the southwest corner of the intersection of West Myrtle Street and South Mason Street. The address is 203 West Myrtle Street.The site is rectangular in shape and contains approximately 0.37 acres. The site's East-West dimension is 65 feet and its North -South dimension is 90 feet. The site is located in the OLD TOWN DRAINAGE BASIN. EXISTING CONDITIONS The site is presently zoned B-G General Business District. The existing structure located on the site was originally a single family residence (Please refer to Original Conditions Exhibit.) A succession of changes in useage of the structure and the exterior site have occurred since the property was originally occupied in 1977. No physical changes have been made to the structure since that time. The structure is presently used as a retail sales outlet for imported products. Several modifications have been made to the exterior portion of the property during this time (Please refer to Existing Conditions Exhibit.) The following is a list of modifications in chronological order: 1. The gravel surfaced areas between the sidewalks and the curb and gutter adjacent to both streets has been removed and replaced with asphalt surfacing. 2. The gravel driveway, concrete walks and some "lawn" area located at the southerly side of the property have been removed. Raised wooden decks and a flagstone surfaced area have been constructed to provide an outdoor seating area for the restaurant located in the adjacent property to the south. 3. A portion of the "lawn" area along the west side of the structure has been removed and replaced with asphalt surfaced parking places. This was done at the same time that an asphalt access drive was constructed on the adjacent property to the west. As previously stated, a restaurant is located on the adjacent property to the south. The area immediately west of the site is an access driveway and residential rental property. The main line of the Burlington Northern Railroad is situated in the center of Mason Street along the eastern border of the site. The site and surrouding vicinity is relatively flat and slopes gently from southwest to northeast toward Mason Street. Slopes range 1 EXISTING CONDITION (cont.) from 0.5% to 2%. The site does not appear to receive run-off from the adjacent properties. The runoff generated on the adjacent properties to the south and west appears to flow overland to the north in the inverted crown section of the access driveway located at the west side of the property. The runoff is discharged into the curb and gutter along the south side of West Myrtle Street. The runoff that enters the gutter in West Myrtle Street flows easterly to South Mason Street. A storm drain inlet is located to the west of the curb radius at the southwest corner of the intersection of West Myrtle Street and South Mason Street which intercepts the flow from the west. A storm drain inlet located to south of the curb radius at the southwest corner of the intersection of West Myrtle Street and South Mason Street which intercepts the flow from the south. The storm drain inlets are connected to a 27 inch diameter storm drain that flows easterly in West Myrtle Street. There are no current plans to modify or upgrade the City's storm drainage system for the immediate vicinity. PROPOSED DEVELOPME The proposed development is to consist of the construction of additions to the east and north sides of the existing structure. The balance of the existing structure is to be remodeled throughout. The exterior seating area for the restaurant to the south is to be retained. The parking area along the west side of the site is to be retained. (Please refer to Proposed Construction Exhibit.) The proposed construction is designed to be able to conform with the existing slope and grades. The site will continue to drain to the intersetion corner of the adjacent streets. The calculations made to determine the peak rate of storm runoff that will be generated by the proposed changes on the site indicate that there will be virtually no change in the intensity or amount of runoff due to the proposed construction. The site has limitations on the space that is available to provide for onsite detention facilities. Therefore, due to this limitation and the estimated negligible change in runoff, it is recommended that no onsite drainage detention facilities be provided. CONCLUSIONS AND RECOMMENDATIONS 1. The proposed development will retain the existing drainage patterns. 2. The site is located in the OLD TOWN DRAINAGE BASIN. The site is not located within a designated floodway or flood plain. 3. All construction is to be performed in accordance with City of Fort Collins' Standards and Specifications. 4. Onsite detention of stormwater is not recommended due to the limited area available to physically develop fully sized facilities. The estimated peak rates of runoff for the proposed construction indicate that there is to be virtually no change from the present and past conditions. 5. The City of Fort Collins' Standards for temporary erosion control measures are recommended to be incorporated with the construction activities. Specifically, a silt fence to control mud from being washed onto the existing sidewalk and street is recommended. 2 OS Engineering Associates April 26, 1991 Project No. HYD-052-91 Stormwater Utility City of Fort Collins 235 Mathews P.O. Box 580 Fort Collins, Colorado 80522-0580 Attn: Mr. Glen Schlueter Re: Drainage Investigation for East-West Imports located at 203 W. Myrtle, Fort Collins, Colorado Dear Mr. Schlueter, Per your review comments, this office has revised the subject drainage investigation report and has performed additional calaculations to determine the affect, if any, by the proposed remodel. Based upon the calculations performed, I would anticipate virtually no change in the drainage characteristics in this area due to the proposed construction. Therefore, on behalf of the owner, I am requesting that a variance be granted to allow the project to proceed without providing on -site detention. �, Your earliest possible response to this request will be greatly appreciated. For your information the owner's contractor is in the process of maldng a submittal for Building Permit at this time. If you should have any questions, please feel free to contact this office. Respect .,Wtz`k °1 �d 1)enni ssne :bc`� MESSN��,e� Associates ��p�n�nAmm►au�� DRM/mkm Civil and Environmental Engineering Consultants 150 E. 29th Street, Suite 225 Loveland, Colorado 80538 Telephone: (303) 663-2221 [E�XAHI : I T I"= 20' WEST MYRTLE STREET . EXISTING INLETS -.- / i , GRAVEL / / EXISTING FLAGSTONE WALK 65' 1 71-" E� LAWN W z 0 o EXISTING r� rn STRUCTURE w LAWN LAWN EXIST. GRAVEL PARKING, 65' EXISTING CONCRETE DRIVEWAY ORIGINAL CONDITIONS EXHIBIT 1"= 20' ADJACENT RESIDENCE & DRIVEWAY WEST MYRTLE STREET ASPHALT a LANDSCAPED EXISTING STRUCTURE LA �1�1-11111� OUTDOOR DINING AREA ADJACENT RESTAURANT ..EXISTING INLETS i i i i i i i EF � w x W N zo, Z O F � M W a O EXISTING CONCRETE DRIVEWAY EXISTING CONDITIONS EXHIBIT 1"= 20' ADJACENT RESIDENCE WEST MYRTLE STREET ASPHALT EXISTING FLAGSTONE WALK & DRIVEWAY REMODELLED STRUCTURE W/ ADDITIONS ADJACENT RESTAURANT F a 0 x DO & III 0 PING CONCRETE DRIVEWAY PROPOSED CONSTRUCTION EXHIBIT Client: EAST -WEST IMPORTS Project No.HYD-052-91 By: DRM Date: Apr. 9, 1991 (Revised 4-26-91) Calculations for Drainage Investigation for 203 West Myrtle Street, City of Fort Collins, Larimer County, Colorado Total Site Area = Lot Area + Adjacent Street Area _ (65 x 90) + (90 x 50) + (50 x 50) + (65 x 50) = 5,850 + 4,500 + 2,500 + 3,250 = 16,100 sq. ft. = 0.37 ± acres The proposed construction on the site is to consist of an addition to the east and the north sides of the existing structure. The balance of the existing structure is to be remodeled. The existing outdoor seating area for the restaurant located at the south property line is to be retained. The existing paved parking area along the west side of the site is to be retained. The following calculations have been performed in order to determine the peak rate of runoff for three conditions. Those being: the condition at time of initial occupancy by East - West Import; the present condition; and the condition after the proposed construction is completed. The existing zoning is B-G General Business District. Therefore, the 10 Year and 100 Year Storms have been considered for the Minor and Major storm events respectively. INITIAL CONDITIONS Rational "C" Factor = 0.15 for Landscaped Areas " ft " = 0.50 for Gravel Surfaced Areas ft it = 0.60 for Flagstone Surfaced Areas ft = 0.95 for Concrete Sidewalks, Driveways, Patios, etc. = 0.95 for Roofs = 0.95 for Streets Area covered by Landscaping (Lawn) = 4,175 sq. ft. Area covered by Gravel Surfacing = 2,175 sq. ft. Area covered by Flagstone Surfacing = 310 sq. ft. Area covered by Roof = 1,750 sq. ft. Area covered by Sidewalk, Driveways, Patios, etc. = 1,140 sq. ft. Area covered by Street = 6.550 sq. ft. Total Area=16,100 sq.ft. Average "C" Factor =[(4,175x0.15)+(2,175x0.5)+(310x0.6)+(1,750x0.95)+(1,140x0.95)+ (6,5500.95)1-16,100 "C"avg = 0.675 Off -site Area contributing runoff = 0 Elevation difference across west side of site = 100.7 - 100.2 = 0.5 ft. Distance from SW corner to NW corner at Street= 100± ft. Slope = 0.5/100 = .005 ft./ft. = 0.5±% Page 1 of 3 Client: EAST -WEST IMPORTS Project No.HYD-052-91 By: DRM Date: Apr. 9, 1991 (Revised 4-26-91) INITIAL CONDITIONS cont.) Time of Concentration determined by the formula Tc = 1.8 (1.1 - CCf)4L,-(S)1/3 Tc = 1.8 [1.140.675 x1.0N100-(0.5)1/3 = 10.5 minutes USE 10 minutes as Time of Concentration due to minimum time of concentration specified in Urban Drainage and Flood Control District -Design Criteria Rainfall Intensity, I, at Tc = 10 minutes Iio = 4.40 in./hr. Runoff, Q, determined by Q = CIACf Qio = 0.675 (4.40) (0.37)(1.0) =1.10 c.f.s. Qioo = 0.675(7.25) (0.37)(1.25) = 2.26 c.f.s. EXISTING CONDITIONS Area covered by Landscaping (Lawn) Area covered by Wooden Deck Area covered by Flagstone Surfacing Area covered by Roof Area covered by Sidewalk, Driveways, Patios, etc. Area covered by Street and Asphalt Paving Total Area Iioo = 7.25 in./hr. = 2,785 sq. ft. = 290 sq. ft. = 1,130 sq. ft. = 1,750 sq. ft. = 1,015 sq. ft. = 9.130 sq. ft. =16,100 sq.ft. Average "C" Factor =[(2,785x0.15)+(290x0.5)+(1,130x0.6)+(1,750x0.95)+(1,015x0.95)+ (9,130x0.95)1-16,100 "C"avg = 0.779 Tc = 10 minutes (Based on Minimum allowable) Iio ® 10 min. = 4.40 in./hr. Qio = 0.779 (4.40) (0.37)(1.0) = 1.27 c.f.s. Qioo = 0.779 (7.25) (0.37)(1.25) = 2.61 c.f.s. PROPOSED CONSTRUCTION Area covered by Landscaping (Lawn) Area covered by Wooden Deck Area covered by Flagstone Surfacing Area covered by Roof Area covered by Sidewalk, Driveways, Patios, etc. Area covered by Street and Asphalt Paving Total Area Iioo Q 10 min. = 7.25 in./hr. = 1,950 sq. ft. = 470 sq. ft. = 1,130 sq. ft. = 2,445 sq. ft. = 975 sq. ft. = 9.130 so. ft. =16,100 sq.ft. Page 2 of $ Client: EAST - WEST IMPORTS Project No.HYD-052-91 By: DRM Date: Apr. 9, 1991 (Revised 5-16-91) PROPOSED CONSTRUCTION cont.) Average "C" Factor =[(1,950xO.15)+(470xO.5)+(1,l30x0.6)+(2,445xO.95)+(975xO.95)+ (9,1300.95)1-16,100 "C"avg = 0.815 0.815 x 1.25 = 1.02 > 1.0 therefore, USE 1.0 for "C"avg Q 100Yr. Tc = 10 minutes (Based on Minimum allowable) 5 w�' ho Q 10 min. = 4.40 in./hr. hoo @ 10 min. = 7.25 in./hr. Qio = 0.815 (4.40) (0.37)(1.0) =1.33 CS..s. Qioo = 1.0 (7.25) (0.37)= 2.68 c.f.s. Determine Volume if Detention were to be provided. 7 (Q2=0.675x251x0.37x1.0=0.62c.f.s. Time Qioo Proposed Vol. Q Qioo pis. ® 2 Yr. Vol, as. Vol. Diff. 10 (min.) 2.68 (c.f.s.) 1,608 (cu.ft.) 0.62 (c.f.s.) / 372 (cu.ft.)1,236 (cu.ft.T 15 2.22 1,998 0.62 558 ✓ 1,440 ✓ 20 1.92 2,304 ✓ 0.62 744 ✓ 1,560Z� 25 1.70 2,550 0.62 930 / 1,620 ✓ 30 1.54 2,772 ✓ 0.62 1,116 ✓ Ll:,65a6--� 40 1.30 3,120 ✓ 0.62 1,488 ✓ 1,632 50 1.11 3,330 ✓ 0.62 1,860 ✓ 1,470 ✓ 60 0.96 3,456 v'-- 0.62 2,232 ✓ 1,224 ✓ Therefore, a volume of 1,656 cu.ft wouldnbe detained if detention were to be provided. Determine increase in depth of flow. OVE Q1oo at initial development = 2.26 c.f.0' Q1oo at proposed de velopment = 2.68 c.f.s.✓ Q = 0.56 (Z/n) 4S(y)7From Section 4.2.2.2 - Theoretical Capacity y = [Q _ (0.56 VS/n)]"� Z = 1/ Street Crown Slope = V 0.02 = 50 at Initial y = [2.26 - (0.56 x 50 x 40.005 / 0.016131$ = 0.223 ft. at Proposed p y = [2.68 = (0.56 x 50 x 40.005 / 0.016] 8 = 0.238 ft. Therefore, the change in depth in the gutter flow is 0.015 ft. (0.18 inches) Page 3 of 3 Drainage Summary for EAST - WEST IlVIPORTS located on the North 90 feet of the East 65 feet of Block 106 of Harrison's Addition to the City of Fort Collins, Colorado Existing Conditions: Total Area = 0.134 ± acres Lot plus 0.236 ± acres adjacent Street R - 0 - W Rational "C" factor: Cio= 0.779 Cioo = 0.779 (Proportioned by direct -area relationship) Onsite Runoff: Q io= 0.46c.f.s. Qioo = 0.82 c.f.s. Street Flows: Q io = 0.81 c.f.s. Qioo = 1.44 c.f.s. Total Runoff: Q io = 1.27 c.f.s. Qioo = 2.26 c.f.s. Developed Conditions: 111 Total Area = 0.134 ± acres Lot plus 0.236± acres adjacent Street R - 0 - W Rational "C" factor: Cio= 0.815 Cioo = 0.815 Onsite Runoff: Street Flows: Total Runoff: Q io = 0.48 c.fs. Q io = 0.85 c.f.s. Q io=1.33�c.f.s. P�h� Detention Summary: Qioo = 0.97 c.fs. Qioo = 1.71 c.f.s. Q= 2.6�c.f.s. , uo I - - On site detention facilities are NOT recommended. If detention were to be provided, a volume of 1,656 cu. ft. would be desired. Drainage Basin Statistics: Gross Platted Area: 0.370 ± Acres Gross Area Rational "C" Factor: C2 = 0.815 Cioo = 0.815 Net Platted Area: 0.134± Acres Net Area Rational "C" Factor: C2 = 0.815 Cioo = 0.815 Onsite Detention: 0 c.f./ac. Basin: OLD TOWN DRAINAGE BASIN Streets: The increased rate of flow during the 100 Year Storm will increase the depth of flow in the gutter by an estimated 0.18 inches. (Revised 5-16-91, DRM) �'F IF NEEc�Pra , Ppo.iIVC' "�+ILT FL h1GE AD.IAGCNT T �i �`^�^J-K IN OPErI LKLA�V4Tlonl A.¢� To Go4-raoL MUD IsGOM �I� �.VAfs HPD IHTo SIDE�.iel-K AN�STQt3ET SHOULD CONSr Ue'") Ud Ny/"oj r,QAUC 1"413 ONTO govgc`,Vr Sr�+EETS , pA/tY ccr.�N�.v4 OF JTaEG71 wr" dE RerJur.te.o. l ,VOW NJ/eNr�� 6O44T.«vS RAVE BEAN iN-6.64rG4I. T,jr °Ovw-./Jio�TS'',4kS TO /3E LNA/NO 4W.0 A16T iNE JRAD O/✓+/At. 'r l�dw,v y/FT �� / 0,A6 1i, dLtL6-( lr-a [-.LIT v or"Rw, aro37 1444 11 i Ipp'!� I - .r 00 Imo„ A NQCAS Iwcwr�r, -TP Ev Y&t244GCf]T 12;411' cr. W4Y �-; Tllv� ��eG4,- cr aAell�- 6Gr,IGF✓•MI+¢4= Go¢NEC OP 464r ewA.LK L o lz µg orF INTC .�CiTlel.l oP HY2"f 1,6 �' MP�*L tLEV, = iC*40•4*-�' (/ifaUMCD �WTu M> .rcic�rr. CGRouup t4ev. CONToJ(1 1� LLCVh'T10P4 d�NToaf _ _k 9°b + IvAn e7VyT, 'Agouuo SPAT nLmwvwrioK 1 Io0 �i' 0� i T Iol 7 I � I arr au'u� ��l.dttsyu� l� LxnT TOP Be r�uNt-wrw1.Lm i� 6101FW VCWP`) r,"T �brz4H 1' 165- iCCM K o C�19T1�-(u(r(v-9To2{ �GI� 31A I;.rJ l 1.1 - CcW NE.12L.16U- USE-. y ' "`. � M1U ILVJlI.1G� Ka7l'T CrJ- � lollw -~ ., 1�1kFL + Y 1 ix f,�5d� 5TI2��"f 0 lol ;,2 I � S J ulu�wq /� 0 0 1 AGL� t as " C:KV-1R, `:ff_tZ, ' wYD -eq -'I it wRM. �} - 2c. -'I I =CO I] Lo • • • • - U. • Ltol a; LLJ IA F- wl ow at CZ CC I PROD. NO. DATE DRAWN CHECKED LMMOMMMMMMMOMMMOMMEI $HT. I OF( `r -