Loading...
HomeMy WebLinkAboutDrainage Reports - 04/18/2000F mal A. proved %W Addendum to the Final Drainage and Erosion Control Study Miramont Valley P.U.D., Fort Collins, Colorado Dated: September 30, 1996 Addendum Date: March 2000 THE SEAR -BROWN GROUP Standards in Excellence ' THE SEAR -BROWN GROUP FULL -SERVICE DESIGN PROFESSIONALS ' 209 SOUTH MELDRUM FORT COLLINS, COLORADO 80521-2603 970-482-5922 FAX:970-482-6368 March 31, 2000 ' Mr. Basil Hamdan City of Fort Collins ' Water Utilities--Stormwater 700 Wood Street Fort Collins, Colorado 80521 ' RE: Addendum to the Final Drainage and Erosion Control Study for Miramont Valley P.U.D. ' Dear Basil: ' We are pleased to submit to you, for your review and approval, this Addendum to the Final Drainage and Erosion Control Study for Miramont Valley P.U.D. All computations within this report have been completed in compliance with the City of Fort Collins Storm Drainage Design Criteria. We appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. Respectfully, ' The Sear -Brown Group ' Prepare'�k by: Reviewgd by: ' /JoeDeHeart Stan Myers, P.E. Project Mm�kG,y�g cc: File 504-029A4�o•Qea Miramont Associates kP s® 06 'llizz�,N,VNA 1 2 NEW YORK•PENNSYLVANIA ' COLORADO • UTAH • WYOMING STANDARDS IN EXCELLENCE EQUAL OPPORTUNITY EMPLOYER 1 1 1 1 1 DESCRIPTION I. NARRATIVE II. REFERENCES TABLE OF CONTENTS APPENDIX EXHIBIT FROM MIRAMONT VALLEY P.U.D. UTILITY PLANS, AUGUST 1996 EXHIBIT OF REVISED STREET CONFIGURATION AND DRAINAGE BASINS DETAIL OF INTERSECTION OF ROMA VALLEY COURT AND MAIL CREEK LANE CULVERT CALCULATIONS WITH EXCEPTS FROM PERTINENT DRAINAGE REPORTS RIPRAP CALCULATIONS SWALE CALCULATIONS CHARTS, TABLES AND FIGURES PAGE 4 0 9 11 14 16 22 24 29 91 ADDENDUM TO THE FINAL DRAINAGE AND EROSION CONTROL STUDY FOR ' MIRAMONT VALLEY P.U.D. FORT COLLINS, COLORADO NARRATIVE A. Location ' The Miramont Valley P.U.D. is located in the southeast part of Fort Collins, bounded on the north and east by Miramont P.U.D. and the proposed Ramparts at Miramont P.U.D. Fossil Creek Meadows First Filing lies to the west of the property. Mail Creek bounds the property to the south. The upper Meadows at ' Miramont First and Second Filings and Castle Ridge are northwest of this area. The entire site is a part of the Oak/Cottonwood Farms Master Plan. Miramont Valley can also be further described as being a part of Section 1, Township 6 ' North, Range 69 West of the 6th Principal Meridian, Larimer County Colorado. B. Description of Property The area described as Miramont Valley P.U.D. is presently partially developed. The property south of Mail Creek Irrigation ditch is partially developed and ' partially native grassland. Topography south of the Mail Creek Irrigation Ditch is generally sloping from north to south at approximately 5%. C. Purpose for the Addendum ' In the Miramont Valley P.U.D. plan set dated August 1996, Roma Valley Drive ended in the west portion of the subdivision as a cul-de-sac (see appendix pg 9). The revised plan set dated March 30, 2000 shows Roma Valley Drive connecting to Mail Creek Lane (see appendix pg 11). As a result, the drainage basins were realigned as needed. The area of Basin 411, decreased from 1.79AC to 1.58AC which reduces the developed flow entering the 10' curb inlet just south of Lot 47. ' The area of Basin 419, increased from 0.69AC to 0.79AC, this will not cause the capacity of 5' inlet north of Lot 54 to be exceeded (see appendix pg 12). The area of Basin 413 decreased from 6.21AC to 6.15AC, therefore, the decreased runoff to Mail Creek is insignificant. 1 4 1 1Q 1 Basin 412 has the biggest changes which include increased area, addition of a culvert with riprap under Roma Valley Drive, and reshaping the borrow ditch along Mail Creek Lane, and realignment of the existing 24" CMP from the school site. The area of Basin 412 increased from 1.35AC to 1.50AC which will increase flows to the borrow ditch. The flows to the north of Roma Valley Drive will sheet flow into the borrow ditch. The developed flows from Roma Valley Drive will be conveyed via the proposed curb & gutter to the 6' cross -pan along Mail Creek Drive and ultimately into the borrow ditch. The culvert under Roma Valley Drive was calculated using information from the Final Drainage and Erosion Control Study for Castle Ridge @ Miramont P.U.D., First Filing, and the Drainage Report for Poudre School District R-1, Werner Elementary School (see appendix pg 17). It was determined that the expected 100 year flow through the borrow ditch and culvert would be 57.8 cfs. The sum of the following individual flows equals the expected 100-year flow. Flows expected from the detention pond in Castle Ridge are 16.3 cfs (see appendix pg 18). A flow of 6.5 cfs is expected from the design point 5 in Castle Ridge P.U.D. (see appendix pg 17). A flow of 31.0 cfs is expected from the Werner Elementary School site (see appendix pg 19). Finally, 4.0 cfs is expected from Basin 412 of the Miramont Valley P.U.D. The size of pipe required to carry this flow is a 36" RCP (see appendix pg 16) with flared end sections on each end. An equivalent 29"x45" elliptical RCP (Class III) will be used so that the pipe is sufficiently below the curb and gutter. The riprap required on the downstream side of the culvert is to be Type VL (Class 6) riprap at 17 ft long, 9 ft wide, and 1 ft deep (see appendix pg 22). The same riprap configuration will be used downstream of the realigned 24" CMP. The borrow ditch will be regraded such that the longitudinal slope upstream of the culvert is 1.5 % for 100 feet and downstream is 1.5 % for 125 feet. Using the freeboard adjusting factor for flow it was determined that the maximum depth upstream is 2.30 ft which is below the 3 ft depth as provided by the regrading as shown in the plans (see appendix pg 27). The maximum depth downstream is 2.30 ft which is below the 4 ft depth as provided by the regrading as shown in the plans (see appendix pg 26). Significant erosion has occurred where the borrow ditch enters Mail Creek. To remedy the situation a new 36" ADS-N12 pipe will be installed with headwalls at each end. There will be riprap placed downstream to prevent erosion of Mail Creeks banks. Conclusion The proposed drainage concepts presented in this study and shown on the revised final utility plans adequately provide for the conveyance of developed runoff from Miramont Valley P.U.D. The concepts shown here will also allow for the development to occur and be in compliance with the Fossil Creek Basin Master Plan, and the Mail Creek Master Plan. This site will also be in compliance with the Overall Drainage plan for the Oak/Cottonwood Farm. 5 II. REFERENCES 1. Storm Drainage Design Criteria and Construction Standards by the City of Fort Collins, Colorado, May 1984, interim revision January 1997. 2. Erosion Control Reference Manual for Construction Sites by the City of Fort Collins, Colorado, January 1991. 3. Final Drainage and Erosion Control Study for Miramont Valley P.U.D., Fort Collins, Colorado, September 30, 1996. 4. Drainage Report for Poudre School District R-1, Werner Elementary School, Fort Collins, Colorado, March 20, 1986. 5. Final Drainage and Erosion Control Study for Castle Ridge (& Miramont P.U.D., First Filing, Fort Collins, Colorado, August 1993. 0 I 1 I �J I 1 1 I I I APPENDIX 1 I ' EXHIBIT FROM MIRAMONT VALLEY P.U.D. UTILITY PLANS, AUGUST 1996 1 I'' r 1 P I r I r 9 No Text I L 1 C 1 w EXHIBIT OF REVISED STREET CONFIGURATION AND DRAINAGE BASINS 1 i ri I 1 11 r 1 Lei No Text 0 Z tl o O W U) N h L W Q 4Z O C a k g N U o a a iO' d c b oO m w a > _ o7 N v� v Ip W 11 Y 3 %b b 3 W v ° o M O 2 •Z ril �} > y>> S flu I LL�B£11¢O a m agi g Fgs5$ Its �8g $ m/1 $ Y Y cab 3y {fi$g8, Y Y Y S {Bg, t € $ $ yhp} S ys PFCC O1 tl C m m m mw_ io a0 i 'i rf O ri'i O n n ri NN atn n nNN n b 0 Nmm O O n n n n q n on n ri Nri N wtl noq bN nm� ��� qoH n 10 m 1nq n n m —o :N .� i . HO � a s Ej 8 8 8 8 O-V 8 0 T FU eO q e n y n� q n m n mn „ 0 M1 0 O n nn yn� wm i m 2 �� V ...' UUU CCU JJJ UJU JUO U U U JJ U 0 J 88 88 R88 888 8R8 8 $ 8 88 8 88 $8 8 yox� J OOESE ddci b LL �LL^ M O O .O' O N i^ b q aie n' �10� 0 0 b roof. H N m m e n q o n n r: g �N mo�om 9 rcLL r o�_ M m Src` 6:o ugia,$1,nw 1qo, Ann �on $ i .�-S 8 m 8� F 3 nRSnmo g__ oo- oN n 0 N-. n o e iN a oo R NNnNo Z^ 8 S C R$ Sin wr: S �R� aS� R A 8 8: 8 R A S8 S R $68:8 m OI �:n r: a IANw woo A 0 ri om ri C ri no r: n •C 1OO 0•6 2_ ^ Na1nO p N10 ENE ENE a ppp SSE Y�1-1 � T H p g0 8 8 G 3 p Ha �1pp Vl p n p o r3$$$$ U 0 o 0 0 o O. O O O C G C C G G G G O O G O O O O C O O G 0 0 0 0 0 ySn EE O n O ri1u 1u H N mci n n; d d 0 1d n O n o00 0 N m o1e� b o n 0 O O ri� q d ry n H ei H N of •i H ei 0 n n 0 b Nm"J N 91 b 0 a _. d ww a:z -. H R N m H .- n Pj b 0 o g*$I LL 6 0 O O Epp O O Q O W ow O n O 00 n n n b n O n q N n 0 0 n O O 0 N q H N H n n n b b n h IC YI p1p oOO IC OGG V1 e O ` ^ n^ 1� O Ci vi Oi oi = $o dam o:nm saner s�nzo S N n p SS' Rasa a s= a= s§ a== 8 a=& -H - 8=s- eggs r^. o I I 11, I DETAIL OF INTERSECTION OF ROMA VALLEY COURT AND MAIL CREEK LANE 1 r I 1 I 1 n J I J 1 H 13 I I 2� 29" 4,4 C (Class I III) 6' P A '1 i Z PURIED RIPRAP- ,�'xl 7'xl � I 28 \8 74 /1 iK C I I r CULVERT CALCULATIONS WITH EXCERPTS FROM PERTINENT DRAINAGE REPORTS I I I I I I ' 9080 700 too = 57.1 40 30 20 10 9 8 7 1 6 5 4 1 3 1 90 84 0.0002 72 66 0.0003 60 0.0004 54 0.0005 0.0006 48 0.0007 0.0008 0.0009 42 0.001 'txPr+ETEt2 36 = 36 iN. 0.002 30 0.003 27 0.004 24 0.005 21 .006 0. 07 0.0 18 " 0.009 0.01 u is 0 v 0.02 E n 12 0 0.03 0.04 10 0.05 0.06 0.07 8 0.08 0.09 0.1 6 0.2 0.3 0.4 4 0.5 0.6 0.7 5r-opE= 1.60/0 2 3- 4- 5 .8 9•H �t�sEL 10 15 0.8 0.9 1 1.0 ' 0.8 20 0. 0.7 2.0 Figure 7.1 Nomograph based on Manning's formula for circular pipes flowing full I6 and with n = 0.013. Z INV, 7 P/ 7% 0or f*p !% 4. 0': T m pc.0 MANHOLE 5" A 4' .14 LON RIPRAF ...:CLASS 'BURY F DETEN T.1 VOLUME 100 2*YR. RELEASE 01 -.1 .. I'll: TOP OF WATER,-'c 24" ADS -;-1,. 5.... 02 -Ar 6' LONG..-'x' 6WID ......... ...... x 18" DEEP CLA$ ....... . RIPRAP w/ 12" 1,'C --------- Z. CLASS. A LVERT (' W 4DE) I v....jHT :,--MAIL CREEK,: Li 20' WIDE OVERF OW WEI TO 0 BERM 4 MAXI UM 01) r1r'Np P� rvi7e =M-3 -F:5 4 48.0 WEIR 20 100 YA p E VfLopfp F1 0 W f�K I?W�`w 5 = 6,5 c 4 OVERFLOW WEI OBB Tis IVJ DESIGNED — CHECKED q3DI n c . Engineering Consultants AUG 1993 504-004 209 South Meldrum Street 2480 W. 26th Ave. Suite 46, Bldg. C 953 So. OVER 0— DATE PROJECT NO- Fort Collins, Colorado 80521 Denver, Colorado 8 211 Voil, Colo. 303 482-5922 303 / 458-5526 303 / 47 1 DETENTION POND SIZING BY FAA METHOD DEVELOPED BY JAMES C.Y. GUO, PHD, P.E. DEPARTMENT OF CIVIL ENGINEERING - _ UNIVERSITY OF COLORADO AT DENVER =II=LLa==LLaaa= =L-3-II--II----a--a a=aIIa=LaaaLLaa=L=L=aaa==L===3=a=3=II==a=LaIIaII EXECUTED ON 10-07-1993 AT TIME 09:20:10 I� I I 1 I PROJECT TITLE: CASTLE RIDGE AT MIRAMONT **** DRAINAGE BASIN DESCRIPTION BASIN ID NUMBER = 1.00 BASIN AREA (acre)= 6.85 RUNOFF COEF . = 0.55 ***** DESIGN RAINFALL STATISTICS DESIGN RETURN PERI00 (YEARS) = 100.00 INTENSITY(IN/HR)-DURATION(MIN) TABLE IS GIVEN DURATION 5 10 20 30 40 50 60 Sy +ex-- +\,e-, � Mai l Cree,k Lo..vti �, T�.e- 80 100 120 150 180 INTENSITY 9.0 7.3 5.2 4.2 3.5 3.0 2.6 2.1 1.7 1. 1.2 1.0 1 • ** POND OUTFLOW CHARACTERISTICS: �}�- LC"G,�- a" MAXIMUM ALLOWABLE RELEASE RATE = 16.3 CFS �� ' �(� �e�r �'} ( S l6 f- t C.• OUTFLOW ADJUSTMENT FACTOR = .8 AVERAGE RELEASE RATE = 13.04 CFS AVERAGE RELEASE RATE = MAXIMUM RELEASE RATE * ADJUSTMENT FACTOR. ***** COMPUTATION OF POND SIZE ------------------------------------------------ RAINFALL RAINFALL INFLOW OUTFLOW REQUIRED DURATION INTENSITY VOLUME VOLUME STORAGE MINUTE ----------------------------------------------------- INCH/HR ACRE -FT ACRE -FT ACRE -FT 0.00 0.00 0.00 0.00 0.00 5.00 9.00 0.24 0.09 0.15 10.00 7.30 0.38 0.18 0.20 15.00 6.25 0.49 0.27 0.22 20.00 5.20 0.54 0.36 0.18 25.00 4.70 0.61 0.45 0.17 30.00 4.20 0.66 0.54 0.12 35.00 3.85 0.71 0.63 0.66. 40.00 3.50 0.73 0.72 0.01 45.00 3.25 0.77 0.81 0.00 ----------------------------------------------------- THE REQUIRED POND SIZE = .2211364 • ACRE -FT E p 1z1�- THE RAINFALL DURATION FOR THE ABOVE POND STORAGE= 15 MINUTES �/ •**** GEOMETRIES OF AN EQUIVALENT CIRCULAR POND ------------------------------------------------- STAGE CONTOUR CONTOUR POND POND (DEPTH) DIAMETER AREA SIDE SLP STORAGE FEET --------------------------------------------------- FEET ACRE FT/FT ACRE -FT 0.00 52.66 0.05 4.00 0.00 0.50 56.66 0.06 4.00 0.03 1.00 60.66 0.07 4.00 0.06 voiv:w-- e-- is +„•v.,ATE S COMPUTATIONS � •�T 1 E SSO�J 214 N. Howes St. Ft. Collins, CO 80521 ' (303) 482-9331 •F &p1e a Z L Client: Poydre School D)sf TZ-! SheetNo.. Z of�_ ,,f'OF ,kdBy: 'bate Project:1257 Ehar•,cal'sty School Job No. ibject `STORM RVN-oFG FROM SCHOOr: SITE. c- ARF_A 14/3oyE .�¢a4 A,'realr�ioo'sfvi.slIr..R.S�. 11i3f1' c.6..�1 =d.Io...�e. _ � J a... s ..c..tIrco�-ne oN; ✓�-l..a� a� if ci;ee . -= a.. .8 L.._ o=_..t. . I C�}srLE - _ •! 1'ij� ---- .:' 'emu. t7. -:•--� j 'i'\_ � _ Ali ' ,--!. "•'F �s`::: Y:,., bYa_e.. - \INN \ •J / + O—?` \ � 1 , r �t 1. �• :. —AI�`'� a �~_ �Q \ y��_4 a ... �'� y^'��y �T�yJ�e'��� .. _ -_ •�� s _,�\\. � - •�,,, a a ; IL ti 01 R� ' .� � ` � �,( JTf..' �t'r er .+' •' J > ~•9 ^Ci.` i� a <- 3 ' r. Y : a�3 •..r -."'t� � •�f --.�__ � -`_ J 'i P 'a ' \.\ � - i ��. � .. � '.� S 1 `, { - .! avt , - lti ` tir ..Yaa�• ✓ s•"� 1 � _ _ � ,`•-\ I' ' < , , . Q '� .'{>_' _ _-A•'=a-s3"�' ice_ .a, `a`•� -' �a�q.` '': •. _^a r \ - ._� J - _-_____ �(�.� p� .l I(�y)�/ .._. _..___ - _ .ems i _ � - 7i,;�- �Y•,•, i �v �r ;;--T ���u. �+ ?..•-" `c l++� �Y�;��:<_S- 4«.?� �' ;�-3.�-_ -__"'_--t_ ��. / _.J.• a�L•�'.r._� F_ 1�4. iV "� '�!(` • `_�L� .. _ �- _� _sJ}J _s.-^tea } ,,.� j"=v'.�. art `'i ''' ?,..ter.;:-' a \.,c••r;:a' f. _ ,'� ... `` _-a• - \ ,a\ •\• ~/ ' } � s .✓. J .c',>' afr• '+ ,tit y♦ 'tf t � ; .i i r � '�F.� =-= `• L� � •• / �_ �\ \\ \ !?'. y �. 'r`� '� .. 1 - it , S; -��, ,-• �; ' •, , .� .) �� % � �\ \\�: \ a oN WlOFO \, 49?i. (\ . — ' PK°PoScD KO VAS / AR\ tl \ ;' , �• , a " 1" H 1 1 1] 1 1 1 i 1 1 i 1 1 1 1 1 1 RIPRAP CALCULATIONS i The Sear -Brown Group UDFCD Riprap Design Project. Addendum to Miramont Valley P.U.D. Designer. • JDH Project #. 504-029 Date: ************ Location: Outfall of 29x45 HERCP Checked. Circular Pipe Outlet ' Pipe dia.: 36 in Tailwater.• Discharge 57.8 cfs Max VeL: 2.07 ft (known) 5 ft/s (soil dependent) 1. Required riprap type: ' Q/D^2.5 = 3.71 < 6 --> use design charts D = 3.00 ft YUD = 0.69 Q/D^1.5 = 11.12 ' d50 = 4.79 in --> 6 in --- > Use Type VL (Class 6) riprap ' 2. Expansion factor.- 1 / [2 tan(theta)] = 6.8 3. Riprap length: At = ON = 11.56 ft2 L = 1/[2tan(theta)]*(AUYt - D) = 17 ft ' 4. Governing limits: L>3D= 9 ft <=17ft-->OK L<1OD= 30 ft =>17ft-->OK 5. Maximum depth: Depth = 2d50 = 2 (6 in / 12) = 1.00 ft ' 6. Bedding: Use 1 ft thick layer of Type II (CDOT Class A) bedding material. 7. Riprap width: Width = 3D = 3 (36 in /12) = 9 ft 1 Summary: Type VL (Class 6) riprap Length = 17 ft ' Depth = 1 ft Width = 9 ft 1 1 15-Feb-2000 oZo2 I 1 i 1 1 1 1 1 1 i i 1 1 1 i 1 1 SWALE CALCULATIONS a.'3 DOWNSTREAM OF 29x45 HERCP ' Worksheet for Triangular Channel Project Description Project File I:\jobs\504-029\data\drainage\project2.fm2 Worksheet DOWNSTREAM FROM ROMA VALLEY CULVERT ' Flow Element Triangular Channel Method Manning's Formula Solve For Channel Depth Input Data Mannings Coefficient 0.040 ' Channel Slope 0.015000 ft/ft Left Side Slope 3.000000 H : V Right Side Slope 3.000000 H : V Discharge 57.80 cfs ■"aQ too tResults Depth 2.07 ft ,f_ .-AK. WA-TEK P95?* Flow Area Wetted Perimeter 12,86 13.09 ft2 ft Top Width 12.42 ft Critical Depth 1.87 ft Critical Slope 0.025562 ft/ft Velocity 4.50 ft/s Velocity Head 0.31 ft Specific Energy 2.38 ft Froude Number 0.78 Flow is subcritical. 00 9:00:FlowMaster v5.15 :00:00 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 a DOWNSTREAM OF 29x45 HERCP Worksheet for Triangular Channel Project Description Project File I:\jobs\504-029\data\drainage\project2.fm2 Worksheet DOWNSTREAM FROM ROMA VALLEY CULVERT ' Flow Element Triangular Channel Method Manning's Formula Solve For Channel Depth Input Data ' Mannings Coefficient 0.040 Channel Slope 0.015000 ft/ft Left Side Slope 3.000000 H : V Right Side Slope 3.000000 H : V Discharge 76.90 cfs ' Results Depth 2.30 ft 41 Flow Area 15.93 ft' Wetted Perimeter 14.57 ft Top Width 13.83 ft Critical Depth 2,10 ft Critical Slope 0.024608 ft/ft Velocity 4.83 fus Velocity Head 0,36 ft Specific Energy 2.67 ft Froude Number 0.79 Flow is subcritical. r I Fop, r-PeE BOA" GQ = (1•33) (0 reo) Q = (/•33) (57.4e4s) F{EQf~rXEt7 (>EP7?-/ 02/15/00 FlowMaster v5.15 09:03:18 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 011 95 UPSTREAM OF 29x45 HERCP ' Worksheet for Triangular Channel Project Description Project file I:\jobsk504-029\data\drainage\project2.fm2 Worksheet UPSTREAM FROM ROMA VALLEY CULVERT ' Flow Element Triangular Channel Method Manning's Formula Solve For Channel Depth Input Data Mannings Coefficient 0.040 Channel Slope 0.015000 ft/ft Left Side Slope 3.000000 H : V Right Side Slope 3.000000 H : V Discharge 76.90 cfs 1 I I I 1-1 I I Results Depth 2.30 ft Flow Area 15.93 ft2 Wetted Perimeter 14.57 ft Top Width 13.83 ft Critical Depth 2.10 ft Critical Slope 0.024608 ft/ft Velocity 4.83 fUs Velocity Head 0.36 ft Specific Energy 2.67 ft Froude Number 0.79 Flow is subcritical. 02/15/00 FlowMaster v5.15 09:01,18 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 tAv DOWNSTREAM OF 24 RCP Worksheet for Triangular Channel Project Description Project File I:\jobs\504-029\data\drainage\project2.fm2 Worksheet DOWNSTREAM OF 24 RCP Flow Element Triangular Channel Method Manning's Formula _Solve For Channel Depth 1 Input Data Mannings Coefficient 0.040 Channel Slope 0.015000 ft/ft Left Side Slope 3.000000 H : V Right Side Slope 3.000000 H : V ' Discharge 53.80 cfs 4111111 Q t a p Results Depth 2.02 ft �-rq tL wA-T6r= Flow Area Wetted Perimeter 12.19 ft2 12.75 ft Top Width 12.09 ft Critical Depth 1,82 ft Critical Slope 0.025808 ft/ft Velocity 4.42 ft/s Velocity Head 0.30 ft Specific Energy 2.32 ft Froude Number 0.78 Flow is subcritical. 1 I r I I 02/15/00 FlowMaster v5.15 09:11:41 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 a7 I r 11 r I 1 r 11 1 1 r L 11 r I CHARTS, TABLES AND FIGURES DRAINAGE CRITERIA MANUAL RIPRAP Fi-r. E t A = Expansion Anale mmmmmmmm mmw,dI NIPAWAVAN FAA Mw� 4. No MEN= .l .2 .3 A .5 .6 .1 .8 TAILWATER DEPTH/ CONDUIT HEIGHT, Yt/D n FIGURE 5-9. EXPANSION FACTOR FOR CIRCULAR CONDUITS 11-15 -82 URBAN DRAINAGE 6 FLOOD CONTROL DISTRICT Uzi DRAINAGE CRITERIA MANUAL RIPRAP )' (0 •- a4( 0 OMEN-- EPAS 0 No APAVE No PAM �+ 6 Yt/D Use Do instead of D whenever flow is supercritical in the barrel. **Use Type L for a distance of 3D downstream. FIGURE 5-7. RIPRAP EROSION PROTECTION AT CIRCULAR CONDUIT OUTLET. 11-15-82 URBAN DRAINAGES FLOOD CONTROL DISTRICT 30