HomeMy WebLinkAboutDrainage Reports - 03/22/1982W. STORM WATER DRAINAGE REPORT FOR DRAKE CROSSING SHOPPING CENTER IN THE CITY OF FORT COLLINS, COLORADO MARCH 1982 ,o1® TARANTO, STANTON Ac TAGGE CONSULTING F:NCINF.ERS PORT C O I. L I N' C O L O R A D O _. March 17, 1982 RE: Storm Water Drainage Report Drake Crossing Shopping Center City of Fort Collins Department of Engineering -Drainage 300 Iaporte Avenue Fort Collins, CO 80522 Attn: Phil Waite Dear Phil: This Storm Water Drainage Report has been prepared for Drake Crossing Shopping Center. Sole variations have been made in the development of the flows from this area, from that which was assumed and outlined in the Valley Forge P.U.D. Study. I believe that you will find these variations self-explanatory. Mark Engwoen reviewed the Valley Forge P.U.D. Report and should be able to assist you. If you should have any questions, please do not hesitate to contact our office. Respectful su� ^� S Tarry Stanton, P.E. Robert H. Schen¢r>`rling, P. TAP,;N=, STANTON & TAGGE CONSULTING ENGINEERS LES:RHS:lla 400A 112 W. 11TH AVE. 6412 S. COLLEGE AVE. P.O. BOX 703 HOLDREGE. NE 68949 FORT COLLINS. CO 80525 HAYDEN. CO 81639 STOPM WATER DRAINAGE REPORT FOR DRAKE CROSSING SHOPPI14G CENTER Drake Crossing Shopping Center is located in the Southeast Quarter of Section 21, Township 7 North, Range 69 West of the Sixth Principal Meridian, City of Fort Collins, Larimer County, Colorado. This development is surrounded to the West by RP zoned, unplatted property and to the North, South and East by the following: A. North - Valley Forge (A Planned Unit Development) B. South - Drake Road and Unplatted Property C. East - Taft Hill Road and the Peoples Church of Fort Collins The average undeveloped slope of this property is one (1%) percent falling from West to East (Exhibit "A"). This development has been previously studied in the Valley Forge P.U.D. Drainage Study. This report expands on the drainage which will be developed from the Shopping Center and explains how this development will affect the RP zoned, vacant property to the West. Drake Crossing Shopping Center consists of 12.11 acres. The land is presently undeveloped and made up of well drained soils. Since the area is less than 200 acres, the City of Fort Collins Drainage Regulations allow a modified form of the Rational Formula ( Q = CCfiA) to be used to determine runoff rates where: Q = Discharge is cubic feet per second. C = Unitless coefficient estimating ground perviousness. Cf Unitless rainfall frequency adjustment factor. i = Estimated rainfall intensity in inches per hour. A = Basin design area in acres. PLEASANT B LAKE VALLEY BROWN FARM CANAL 3rd FILING FA DRAKE i ROAD CROSSING /ALLEY FORGE P.U.D_ DRAKE CROSSING SHOPPING CENTER EXHIBIT A LEXINGTON GREEN OVERALL DRAINAGE BOUNDARY DRAINAGE COLLECTION POINT 9929Tro.e e.a .• aoa e. eo a .f■917�{CRY■1 uv<<nw< The City of Fort Collins has specified the unitless coefficient values based on zoning. The zoning of this area is BP and the coefficient values are as follows: 2 & 10 YEAR STORMS Undeveloped Conditions Developed Conditions C Cf C Cf .2 1.00 .85 1.00 100 YEAR STORM C Cf C Cf .2 1.25 .85 1.25 Rainfall intensity is determined by estimating the time it takes to concentrate the maximiun discharge a storm can create at a point of collection. This is known as the Tine of Concentration. The City of Fort Collins Drainage Requirements estimate the Time of Concentration by the following equation: Tc = 1.87 (1.1 - C C€) D" where: S 1/3 Tc = Time of Concentration in minutes. C, Cf = Unitless coefficient previously described. D = Maximum length of design basin in feet. S = Average basin slope in percent. Rainfall intensity is correlated to Time of Concentration by the Rainfall -Intensity -Duration Curve (Exhibit "B"). Rainfall Intensity is measured in inches per hour. All runoff from the area shown on Exhibit "A" presently drains to a existing drainage swale and 40' easement which parallels the West right-of-way of Taft Hill Road from Drake Road to the north property line of Valley Forge P.U.D. INTENSITY -INCHES PER HOUR m Nd C --I m m O N m 7 -0 p - a a N 0 a Z Z I ca D Ci 1 o I o o i N U O o T ' a �- Z -n .0 n 00Z� 0 M 77 n o D a n o _ d " N 0 a -n 0 0 0 3 Z cn ° 00 CD n n D r 0m D J N N Z 0 Q 1 2 c ldJ -- in c_ u F r Q U W m O J U Q r O N C N N N �• C O O O O O O O Z W J �+ LL O L1 CD O L^^. O O m . O O 6n Q W V .-1 M M M M Q Q — W t.n Ln 1f1 lf1 Q W W O i, M W Qv s a O LLJ W a o i Z N Q _Lo , -IT Ln O x v o o -i C U Ln W M O { �r M N N N Ln O N O N U W' a 0 0 0 `— c7 a. x 0 o 0 0 lL O O o 0 Z ,� .--i .-� W•--i -i Q y CD O N N N N c Q Q W W w a IL v m w a pp N O i N O N O O Q ri � J Q Flow in the swale drains from North to South an enters a storm drain inlet at the south end. Upstream of the inlet is a 24-inch R.C.P. storm drain which carries runoff from Brawn Farm Filing No. 3. At the inlet, the storm drain increases to a 36-inch R.C.P. It has been calculated that the increased capacity of the storm drain at this point is 50 c.f.s. (Appendix "A"). Drainage figures for Valley Forge P.U.D. have been developed in the Valley Forge Drainage Study and are presented on Table 1. The developed flows include all of Valley Forge Drive and that part of Hampshire Road shown on the Valley Forge design drawings. The Drake Crossing Shopping Center consists of 14.66 acres. This includes the remainder of Hampshire Foad from Valley Forge Drive to Drake Road. Tracts B and C are also included in this study. Since the entire area is zoned, BP, developed runoff figures for Drake Crossing Shopping Center will include tracts B & C as if they were to be developed. The drainage from tracts B & C described above will flow directly into the drainage swale. This should preclude the need for an additional drainage study for these areas. The only area which will contribute drainage to this site is the RP zoned area to the West. This area consists of approximately 20 acres. Drainage from this area will have to flaw to the existing 36-inch storm drain. We have allowed for this by sizing the storm drain that goes through the Shopping Center so that the estimated 2-year developed flow of 14 c.f.s. (Table 2) can also flaw through the pipe. This capacity will also be able to handle the 100-year undeveloped flow. Once developed, the 100 year developed flow will have to be retained on site. This retention is estimated to be 1.60 acre-feet (Appendix "B") . Die have evaluated developed flaws for the Drake Crossing Shopping Center for the 10-year and 100-year storms as required. Also evaluated was the 2-year storm. The reason for this was to correlate the findings of the Shopping Center to Valley Forge P.U.D. and the RP zoned area to the West-. Undeveloped, the flaw from the Drake Crossing Shopping Center, the RP zoned area, and Valley Forge P.U.D. flows from West to East. The entire undeveloped I RE J U � N Ln OD d N .-1 N Lr) Ln OD d N .-1 N Lr) Ln o OLn N r-1 r1 r-I N �i W U U N N N O Ln d N W O O o r+ 0 0 0 Cd U N N 0 0 0 CD 0 N N W °i a o � a — v Q W uj 0 W W 0 Q N l N > W 0 Z Q }� O 0 am i Q d' to O\ M In r-1 O Ol r-i O Q M ri O to d` O IT M O In M O o C InlnCD Ocm) 0 p00 op0 000 I, I, O m D1 O N N O ID ID O I- I- O OD N In N N In O O In .-i .--1 1n O O In .--I O O In O O m O O In O O In 0 0 In •- O O N O O N O O IN O O N O O N V U In In In In to In In In In In In In In In IIl N C0 O W C0 N CO CJ O0 C0 OD OJ 00 00 CD W a O J N 0 o p 0 0 O 0 0 O p Q S f- — CO LL O o 0 p CD Z In IO W N N W Pl I- V' 1,0 In J W v o -1 c o S Q Q N d' N M . O Q W 0 K O LU N r N i N N N N >2 N r W Q .- I N O O N N Cl O M N O O C N O O In N O (D Z .--I CZ) --I'-1 CD .--I O .-1 O .--1 p W � cc yy.�II a 0 N U N d CO d CO U _. cp ` C N r N r v _ N111O L' al alO MMO (i a F- mrvi airnUn I a O O O N QN O Ln Ln Ul to Ln Ln U rococo mrom w a 0o 0 Q 1- - o 0 .. N o Z U. _ c <r w J Q — Ln o w V Q w Sa to s� ro��tl w a Qrtf v�v """ U rr� OJ w O (y� N O ui (}6� N O , O f 0 r C) ui Z N F w O Q S O area, Exhibit "A", consi-sts of approximately 40 acres. Table 3 outlines the expected undeveloped flow data for the 2, 10 and 100-year storms. It is found that the extra capacity of the 36-inch storm drain is more than adequate to handle the 100-year undeveloped flow from the entire undeveloped Exhibit "A" area. The developed flows from Valley Forge P.U.D. will drain totally into the retention area provided along Taft Hill Road. No intermediate on -site retention is provided. For the Drake Crossing Shopping Center, the project will consist of five (5) drainage areas in the developed state plus tracts B & C. These areas and the direction of flows are shown on Exhibit "C". The flaw figures for these areas are given on. Table 4. The drainage plan for the area is to discharge the 100-year flows from the site as quickly as possible. Based upon a release rate of 50 c.f.s. in the 36-inch R.C.P. for the area shown on Exhibit "A", the following plan for its use is advised. At the time the Drainage Study for Valley Forge was prepared, it was assumed it that all developed drainage from the Shopping Center would also drain directly 0 into this swale. As can be seen on Exhibit "C", this is not longer true. ' Only that drainage from Area 4 and tracts B & C flow into the drainage scale overland. These areas combined with Valley Forge P.U.D. have a 100-year developed flow of 62.9 c.f.s. The new storm drain which collects drainage from the Shopping Center and the RP zoned area has been designed to let another 25 c.f.s. enter the exi sti.-ig 36-inch storm drain. The drainage from Area 5 and Drake and Taft Hill Roads h will flow on an existing inlet on Drake Read. This inlet will allow a inflow uof 6 c.f.s. Retention for all flaws over 6 c.f.s. from Area 5 and Drake and _ Taft Hill will be on the street. Subtracting 6 c.f.s. from the 50 c.f.s. capacity available, a remainder of 44 c.f.s. can be allowed into the storm drain from the drainage swale. The new •'1 . storm drain flows directly to the 36-inch storm drain. Therefore, a 19 c.f.s. Iinflow is allowed for Area 4, tracts B & C and Valley Forge P.U.D. The retention for this area has been calculated using a mass flow diagram. This is shown in Appendix B and it was found that retention of 1.40 acre-feet is needed. The existing drainage swale can easily handle this retention. I Retention will be required in Areas 2, 3 and the RP zoned ara. The storm sewer has been designed to drain a 2-year storm for areas 1, 2 and 3 and the 2-year storm for the RP zoned area. It is impossible to drain the 10-year storm as required because of the size of the existing storm drain under Drake IRoad. We have been able, though, to provide adequate retention. It has been calculated that the RP zoned area will generate 14 c.f.s. during the 2-year developed flood. The retention required for this area is the difference between the 100--year and 2-year developed storms. At the time ' retention is built for this area, careful design will have to be done so as not to allow more than 15 c.f.s. from entering the drain. For the present 100-year undeveloped flood of 15.5 c.f.s, the water will flow onto Iiampshire Road and enter the rain through a inlet at the low point. This inlet should i have a throat opening of 8-feet. There will be a slight backup of water, but I it will occur only during the 100-year undeveloped flood and be eliminated when the RP area is developed. Calculations for Area 1 show that the 100-year developed storm will generate 14.9 c.f.s. The combination of the two 8-foot inlets on either side of Hampshire Road will provide enough capacity for this drainage. Since the Time of Concentration for this area and Areas 2 and 3 are approximately 1/3 that of the fastest Time of Concentration for the RP zoned area in the developed state, water from these areas should be out of the storm drain and well down Spring Creek by the time the concentrated flews from the RP zoned area enter the storm drain. Therefore, the entire 100-year developed flcod fran Area 1 can be totally drained and no retention will be required. For both Areas 2 and 3, the storm drain has been designed to handle the 2..year developed storm. Retention is greater than that 10-year developed storm, but this can be adequately provided as shaven on Exhibit "C". The inlet for Area :. t will have to have an 8-foot throat opening and the inlet for Area 3 will be adequate by using a standard 4-foot opening. Appendix "B" also shows the mass diagrams developed for retention design for Areas 2 and 3. The retention required for each area is as follows: Area 2 = .40 acre-feet Area 3 = .25 acre-feet The retention perimeters for Areas 2 and 3 are shown on Exhibit "C". The worst depth of water expected to occur during the 100-year flood which would be in Area 2, will not be more than one (1) foot. Because of the changes made in the location of retention in the Shopping Center, retention should not be needed on the Valley Forge site. Roan is now available within the existing drainage swale along Taft Hill to do sane landscaping and still maintain adequate retention. If there are any questions regarding this study, please contact our office. Respectfully submitted, Robert H. Schemparling, P.E. Tarry E. Stanton, P.E. TARANTO, STANTON & TAGGE CONSULTING ENGINEERS RHS:LES:lla APPENDIX "A" _JOB KO..Z/i' �VC T1M+111. su+rn• T�..or uY +.•ir.v<. e...•.e..+ PROJECT FE /omit.=tlt•iaC eueuL•noes FOR r°n .mri++.rm RR+ea q MADE EY rN. S. D•TE / Z CHECKED BY -DATE SKEET / OF /�P,vENoix •�/� �, C2F%_c 11v-A(vACfrf Or E)(/Sriij4 „y /•r�/� ,Q,C,�. is cr q SCoPE of Q.60 c.As. C1'4,M N p�E,t J C�ttucAr a� 3G /?. C. P, f s q 7 4 S co .y- OF 1. iSr °/ Q = 7Z? c./:_. sAr so IaC /2EAS£ /N CAGFC rTY T I Z ET G r- ,S ro z rn pR A!N ' - CLIENT_ �_�. •__< / IT h I) .'. .__JO! NO. •H nl�,. .�,.,•u K. PROJECT Lj�P kF CO f+'. !� CALCULATIONS FOR �KP/N%.IiG NODE lY_ORT ^' lZ CHECKED!)' DATE__UfET__ ?Of �PPEr�0ix 'IA ,I 3( CAN VFti nus, a� mEZ1$ao Y= ��y`` �3y�s�•o�ly�� V= lo.00 &/se.• 4 = V.f, = 10.0-0 �+IzeL. /acj ; AO ,, a c. l pA c /T/ /S f' FLIau,V!. FULL R - Y)' • Ol2 ��- F of 1� z)Z ti - y 62k . o.k. 36 " (Z, 1•Ili 'l. y 7.()D 4 Z — 7 o J - s. 70 Sys — /7..)" sr9 f . sv .'c.�s . �_ APPENDIX "B" 1% 1�At.m ♦I..I m,A T41.1,1 PROJECT `'P �^ r_ ,i C 1 l 1 L CALCULATIONS FOR J% F' I! )ii•I. t MADE BY _DATE 11yN 67-CHECKED BY DATE SHEET I OF QIAaT'o STUa/n DY(A.N TrmE Lioo C c�a Q � 5c1 7 600 z.� 5.Z- O 3a 4.i 1Z•s SZ.S 1bOo 90 3.S IZf 93rB 2400 g0 Z•v �2.f 3z, � 300 0 Lo Z•o 12•S 32.5 �600 �,, �,: li•S 28r8 4tuo 2?A SyOo 1� 1.7 '1 V000 Our F c,O � U UI �t YnE @ It Cd� D,g_vv mo. 5 LSD � 9000 �8 00 v 1 Z000 60000 4 `i SOCi Z70 a o 67 So 0 10 5 IZO 3600� 6°l IZO IIz, 00 4Too 0 67s00 It7o00 54000 zo`t6o 6s000 126zlio 72000 1285zv 810o0 127000 °jouoo MA,%. occu.2S fRT qo colw. = 64120 I . 6 Oya CiZE - ;= l • f Tu.. rn. Tu...I . o...I I, .nl Vs BEN n ola 0 INTU L'Ce A CLIENT_�j. (�f)��+�HtT-'.tu _Joe NO. FPOJECT1 114',"cIlt,4CALCULATIONS FOR �(G iLI(J[i.4C MJOF BY � !l � DATE^-� �U 1(•�CNECNEO eT WTE eN!!T � OF I Q`,g),zto wz Jwn �nn FLJJNCr Tflvx- )�If•7� puT:Gu •✓ T..nc �raa e ec a � (4) sai v ol,�m & /q, � n i � FJ Tl0 IJ ^� 7 IA S6•B 60o SZo%a I1'}00 LIA s.Z 12.4 C>`+•i 1700 774/00 ZZeoa 5 9 6 0 0 3� 4.Z 17,y 52.1 (boo 13790 34700 a 9 S$y V0 5.5 12.q 143•`I Lyoo l0y/60 1IS600 S8 Sbo So $.0 1-Z.(1 37,Z Zoo ///bop S7000 60 Z.G 12•U 32.2 &" //S92n G'e400 70 1.3 I2-y 28•S 'J-LQo //770o 74 ao%--� $o 2.1 17•y Z(.•o 4WD /2�wo °11"Zoo r, (.1 12-y Z3.6 sqo' /ZW O 10Z000 Ll III 21.1 cove 126400 11 yo00 fn124- 0E-m(u:1or-j fr7 70 rnlN - = S4Sba �� 1.y0 1ic2c— 1=(- cucNr_ i��N Slt jJ� W Fi£ _—_._._JOB NO.2I I- UJ 6- %I c- PROJECT Mfn mil. 11� _CALCULATIONS FOR 0�IN nn T M1OE BY O<� Fi S O,IT EL `� � Z CNECRED BY DATE SHEET J OF ke ov(�„pan Folz IAa ea Z /iDtc:tiriti O o 6 �- rm" lu0 C �'.� /� Q II �T� s<c, u u lu M �. oJCFco v' {� B c.�s pF_TEih.Ru...a 1Lp l ZA(" 4800 1376 0 12 Z6 Q80 9600 1 7z80 3o c1,2 q,3 Id. 1 leoo 3ZSbo (4400 18180 4o g.� y,3 IS.1 tVoo 36'2y0 157_00 I7o`i� ro z,0 4.3 1.1 300-0 3870D Zyao-a 6= 2.G y,: I I. Z. 360-0 q03 to ZZ600 70 Z,3 4,3 9.Cl 4Zoo 4IS30 33600 %0 Z,I y,3 5,v 4`l00 y32c)a 39400 Y0 I,`( 4.3 Q,Z y4a� yVZ70 43200 100 1.7 4,3 -7.3 00v0 g3800 41(000 l � YY�AyI lNVY.� rF.T�.Nn3F OCLu9I . /I Z) A Ca..E - 1-}• ppg ■ � �H 1INi. t�AIN.IH �� dal u•♦nn JOB No, _ n \ PROJECT ,� mfl4.C%AL CALCULATIONS FOR MADE EY "" _DATE"'` 101 1? 2`NECKED BY DATE SWEETzi OF� IZTrcNT10ti1 FuZ �k 3 1"70 Srogr 04 AIN S. �C•' iao 7 2-6 1Z.i Gov 101 zJ 3000 Zv $•Z 7,6 13,5 1700 16Zvo Gouo 31 d•Z z,L �o Y 1600 J96zo 900 0 90 3•s 7..0 q,) M00 v $40 IZ000 ro 3•0 300o 7-3400 1 o o ao 2-c. 7,c G,4 3600 ggcOO l'i 000 7z Z.3 Z•c G•o 4too Zszoo Zl000 7.6 S r 4to o 26y oo 7,140 o 0 ZC el.I SLh 26400 7-700 21c q.Y 6000 U400 -?coo,-:) iE ►I M+-.) -71 Z c-> 0Zoo lo6zo 12Lp (h 14-YI MVM pq,T"t�NnoN O«VRI 3U 'MIN = �Of--,<7 FT