Loading...
HomeMy WebLinkAboutDrainage Reports - 09/14/2010Revision No. 1 To The Drainage Report For Drake Crossing Shopping Center Our office has partially revised the grading plan for Drake Crossing Shopping Center. The reason for this revision is because we discovered that a stockpile of fill material intended for this project was not of the quantities originally assumed to be available. To avoid importing more expensive fill to this site, we have lowered grades to generate additional on -site materials. The grading changes made have slightly changed the size of developed drainage areas 1, 2 and 4, but the drainage patterns outlined in the original report have remained the same. The areas of the developed drainage areas are as follows: Area 1 - 2.80 Acres Area 2 - 4.40 Acres Area 4 - 1.90 Acres The outline of the new drainage areas can be seen on revised Exhibit "C". As shown on this exhibit, Area 2 now includes the Safeway Store. This means that the overall additional drainage area which is proposed to be drained by the storm drain running through the project is increased by the area of the Safeway Store. With the help of ZVFK Architects, we have calculated the 100-year storm flows which will be developed from the Safeway Store roof and have provided for retainage on the roof and a discharge from the roof to the storm drain of 1 c.f.s. The roof area is 1.1 acres, and therefore, the revised flow figures for Area 2 were calculated based on a area of 3.30 acres. The revised flow figures for revised developed drainage Areas 1, 2 and 4 are shown on Table 3-A. These flows will be drained by a 10" diameter storm drain which is shown on the utility plans for .Drake Crossing. As described in the original drainage report, the existing 36- inch R.C.P. culvert under Drake Road, which will carry storm waters from this project, Valley Forge P.U.D., and the RP zoned area to the West to Spring Creek, has 50 c.f.s. capacity. We designed this to allow the full 100-year developed drainage of approximately 15 c.f.s. from Valley Forge P.U.D. to enter this 36-inch R.C.P.. We also allowed 10 c.f.s. from Tracts "A" and "B" and Area 4 to enter this same pipe right-of-way. These flows will enter the pipe at the Southeast corner of the property through an existing inlet. Detention for the remainder of the 100-year flows from these areas is provided in an existing det- ention area along the East boundary line of this project. The remaining 25 c.f.s. capacity of the existing 36-inch R.C.P. pipe is made up of flows provided by a proposed storm drain. We are not proposing any changes to this system. We merely provide for slightly different retention schemes on the shopping center sites. The storm drain system to the first inlet, which drains Area 3, will remain basically the same. See Exhibit "C" for revised volume and depth anticipated. Area 2 drainage will now flow to two (2) 4-foot inlets instead of one (1) 8-foot inlet. The flow entering these inlets from the parking areas is slightly less than what it used to be, therefore, retention in the parking lot itself will also be slightly less than outlined in the original report. The controlled discharge from the Safeway Store will be tied into the storm drain at the downstream inlet in this area. Enclosed are the architectural plans for the Safeway design. This 1 c.f.s. brings the total discharge allowed into the storm drain from Area 2 to the same flow as provided for in the original report, 11.7 c.f.s. Finally, in Area 1, as originally designed, allowed.that the entire 100-year flow to enter the storm drain. The reason for this was because the storm drain was designed to eventually drain the RP zoned area to the West. Old Area 1, developed the same 100-year developed flow as the 2-year developed flow for the RP zoned area and it was proved that the time of concentra- tion of area was substantially shorter than that of the RP zoned area and developed waters from Area 1 would be well down the storm drain before the 2-year developed concentrations from the RP zoned area entered the pipe. This flow was calculated to be 15 c.f.s. The 100-year developed flow has increased to 16.7 c.f.s. in this area. A small amount of retention will now occur. This volume has been calculated as 3,540 ft3 and the mass flow dia- gram is attached with the revised work sheets. This volume will not provide over .5-foot of depth and should not hinder public movement. In addition, even with the small amount of retention now provided, the water will still drain and vacate the storm drain before the volume is required for the RP zoned area. We still need and would like to have intact, the variance allowing the 5-year developed flow to drain from this site for the same reasons it was originally requested. Slopes for the storm drain will remain the same and the length of the throat openings are sized the same as before, therefore, inflow into the storm drain is the same as originally planned. It is important to note, the discharges carried by the piping shall remain the same as the slopes have remained the same. If you have any comments, please do not hesitate to contact our office. Respectfully submitted, #-5. b7 Ll g. EL-0 Robert H. Schemmerling, P.E. TARANTO, STANTON & TAGGE CONSULTING ENGINEERS RHS:llf DATA TABLE 3-A Developed Area Length Avg. Slope C Cf To I O = CCfIA Drainage (Acres) (Ft.) M (Min) (In/fir) (cfs) Area 1 2 yr 2.8 360' 2.0 .85 1.0 7 3.0 7.1 5 yr 2.8 360 2.0 .85 1.0 7 3.7 8.8 10 yr 2.8 360 2.0 .85 1.0 7 5.0 11.9 100 yr 2.6 360 2.0 .85 1.25 10 7.0 16.7 Area 2 2 yr 3.3 330 2.0 .85 1.0 6.7 3.0 8.4 5 yr 3.3 330 2.0 .85 1.0 6.7 3.8 10.7 10 yr 3.3 330 2.0 .85 1.0 6.7 5.1 14.3 100 yr 3.3 330 2.0 .85 1.25 10 7.0 24.5 Area 4 2 yr 1.9 620 1.0 .85 1.0 11.6 2.4 3.9 5 yr 1.9 620 1.0 .85 1.0 11.6 3.4 5.5 10 yr 1.9 620 1.0 .85 1.0 11.6 4.2 6.8 100 yr 1.9 620 1.0 .85 1.25 10 7.0 11.3 L \♦ILi1Vl. [\41\ilk\ MADE BY DATE CHECKED BY -)-JOB NO. CALCULATIONS FOR SHEET 7% ro/Z �C%NJ'7J/i'J /N �%f/1 I f C�sJ l l�/Y � tl ifr Vow✓r•.��LT3) t)Ui-'�C.L�ppv G� IJ' cT-5. /o -7 ,?.98 �20,9 6o-fl Izs<lo g000 2� r•Z Y /5•S /Zoc f86�o tC000 V,z z.59 iz. >/ >t� Lz�a ;27oa `(o 6a SD 700 60 Z.0 Z.4Y 7.7 s�.� 277Zo 70 z.3 Z,iB 6,7 Yzoo ?,&Ito 60 2,l Z.Yx 6.3 14%�a 1,7 7,iv -7 sioa /oo /.7 z,1b S I 67ou F\Yfl.i� zv.Nnalti �7- a