HomeMy WebLinkAboutDrainage Reports - 04/19/1974V)
w
w
,A
J
"T
LLL;
D
T
L
N
1/5
April 19, 1974
File No. 39-8-20
Wheeler Realty
1331 8th Street
Greeley, Colorado 80631
Re: Drainage Study - Brown Farm 2nd Filing
Gentlemen:
At your request, we have prepared a storm drainage study for Brown
Farm 2nd Filing, Fort Collins, Colorado. Brown Farm 2nd Filing is
a residential subdivision located in Section 21, T7N, R69W of the
6th Principal Meridian. The topography of this tract is gently
rolling hills, formerly irrigated crop land. The Lake Canal
irrigation ditch flows generally through the project from North to
South. This irrigation canal will receive partial runoff waters
from the development. Coordination and approval have been made with
the Lake Canal Company in this regard. This tract lies at the high
point of a ridge with drainage to the North and South of this high -
point. A small portion of this subdivision will drain directly to
the Canal while the majority of the subdivision will drain overland
and by way of street flow and channel flow to a retention pond located
to the Northeast Corner of the Brown Farm Subdivision. A portion of
the tract will drain South into the existing irrigation Swale.
DESIGN CRITERIA
The rational method of design as outlined in "Design and Construction
of Sanitary and Storm Sewers" prepared by a Joint Committee of Water
Pollution Control Federation and the American Society of Civil
Engineers is the basis of computation used in this study. This
method is based on the formula Q = CIA explained as follows:
Q = The discharge of storm water in cubic feet per second.
C = A runoff factor - the runoff factor is a coefficient that
approximates the amount of rainfall running off of a
particular area and takes into consideration various factors
that effect this runoff such as soil features and type of
improvement. For this report, a runoff factor of 0.5 was
used for all land that is to be developed as single family
residences.
Wheeler Realty
File No. 39-8-20
Page 2
April 19, 1974
I - Intensity rate of rainfall - for this study we have used an
intensity frequency curve developed by Black and Veach
developed for the Fort Collins area for storms with frequencies
of 50 years or less. Additional rainfall data was needed in order
to determine an intensity curve for a storm of 100 year frequency.
This data was obtained from the Colorado State University recording
station in Fort Collins. The 100 year rainfall intensities as
plotted on Exhibit No. 3 are within 10 percent of data taken from
the U.S. Department of Commerce, Weather Bureau, Technical Paper
No. 40, repaginated and reprinted January 1963. Therefore, the
100 year intensity curve was used as the design basis throughout
this report. The 100 year curve was used to determine capacities of
pans in easements, drainage swales and street sections.
A - The area contributing storm water runoff to any particular point
in the design considerations.
EXHIBITS
The exhibits accompanying this study are:
1. Location Map
2. A set of 4 plan sheets indicating the drainage areas used, detail
sections and general development of the Tract.
3. Rainfall intensity frequency curves.
4. Calculations.
STORM DRAINAGE DESIGN
This tract is divided into four design study areas.
Area A Romeldale Lane
Area B Ryland Lane
Area C Hampshire Road North of the High Point
Area D Hampshire Road South of the High Point
Area A - Romeldale Lane has a high point at Zenith Court. Zenith Court
is on the East side of Stuart Street and the drainage from this area
crosses Stuart Street in a drainage pan at Romeldale Lane and flow is
generally westerly to the cul-de-sac at the west end of Romeldale Lane
at which point flows are directed overland in the drainage easement
between Lots 18 and 19, Block 8. A drainage pan carries the 10 year
storm flows to the open space and drainage Swale west of the subdivided
Lots. The drainage swale runs northerly to an existing drainage swale
in Brown Farm First Filing.
Wheeler Realty
File No. 39-8-20
Page 3
April 19, 1974
The design of this area considers a 100year storm flow to pass through
the easement at the West end of the cul-de-sac on Romeldale Lane with a
drainage swale to the North along the open green area West of the
subdivided portion. A drainage pan in the easement between Lots 18 and
19, Block 4, was designed to handle a 100year storm.
Area B - Ryland Lane. The high point is to the West of the boundary of
the Brown Farm 2nd Filing. The flow is overland by way of street flow to
a low point on Ryland Lane between Lots 6 and 7, Block 4, at which point
overland flow is by way of a drainage pan generally Southeasterly to the
Lake Canal Ditch.
The design shows that storm flows can be carried between the two houses
on Lots 6 and 7, Block 4. The drainage pan was designed to carry the
100year storm flows by way of a drainage pan to the existing irrigation
ditch to the Southeast of these two properties.
Area C - Hampshire Road, from a high point between Marianna Court and
Panama Court. The flow for this area is generally Northerly to the boundary
of Brown Farm First Filing. These flows will be overland by street
flow and continue overland through the Brown Farm First Filing until
they enter the drainage retention pond at the Northeast corner of the
entire tract.
Area D - Hampshire Road, South from the high point previously described.
The flows are generally overland by way of street flow to a point at the
south boundary of Brown Farm 2nd Filing at which point flows will enter an
existing irrigation ditch.
For Areas C and D the design was based on a100 year storm with all the
flows going to Hampshire Road and a cross section of Hampshire Road is
shown indicating the maximum capacity at the top of the curb and compared
to the design flow of these particular areas.
CONCLUSIONS
It is observed that storm flow from the Brown Farm 2nd Filing can be
adequately handled either by overland flow along proposed streets or
through constructed drainage swales as noted on the attached exhibits.
RECOMMENDATIONS
It is recommended:
1. That storm water swales be constructed in accordance with the
details shown on the drawings,
Wheeler Realty
File No. 39-8-20
Page 4
April 19, 1974
2. That minimum street grades of .4% be maintained,
3. That minimum overlot grading standards of the Federal Housing
Administration be observed in the construction of residences.
Very truly yours,
HOGAN & OLHAUSEN, P.C.
Max A. Karner
MAK/car