Loading...
HomeMy WebLinkAboutDrainage Reports - 12/05/1997w ev,kop RTy OF S Final Drainage Report for Evergreen Park Second Filing Fort Collins, Colorado November 10, 1997 Final Drainage Report for Evergreen Park Second Filing Fort Collins, Colorado November 10, 1997 Prepared For: RJ Develco 605 South College Avenue Fort Collins, Colorado 80524 Prepared By: MENUMN Northern Engineering Services, Inc 420 S. Howes, Suite 202 Fort Collins, Colorado 80521 Phone: (970)221-4158 Project Number: 9611.00 November 10, 1997 City of Fort Collins Stormwater Utility 235 Mathews Fort Collins, Colorado 80522 RE: Evergreen Park Second Filing Third Replat Fort Collins, Colorado Project Number: 9611.00 Dear Staff: Northern Engineering is pleased to re -submit this Final Drainage Report for Evergreen Park Second.Filing Third Replat for your review. This report was prepared in compliance with technical criteria set forth in the City of Fort Collins Storm Drainage Design Criteria and Construction Standards manual. We have addressed the comments contained in the `Project Comment Sheet" dated October 2, 1997. If you should have any questions or comments as you review this report, please feel free to contact me at your convenience. Sincerely, NORTHERN ENGINEERING SERVICES, INC. k✓N - v" Mary B. Wohnrade, P.E. +`�1 FP*)o K � c trr�'e 303,2,"g.; $. z' 420 SOUTH HOWES, SUITE 202, FORT COLLINS, COLORADO 80521, (970) 221-4158, FAX (970) 221-4159 I i :,It REVISION wr COMMENT SHEET DATE: October 2, 1997 DEPT: Storm Water ' . PROJECT: #24-96 Evergreen Park Subdivision, Third Replat, 2nd Filing - (LDGS) Replat PLANNER: Leanne Harter All comments must be recieved no later than the staff review meeting: Wednesday, October 22,1997 As you review the project, Bob Blanchard would like to be notified of issues as they are discovered. 1. A cross-section of the existing swale along the north property line should be provided. It must be shown that the proposed depth in the Swale is less than the existing depth in the Swale. RESPONSE: So.,n-g- I`A. FZ/ -T7-t7.- INAS Lram)='r- c •"-r or "'rt'FC ra+-C ✓l o�n t /�-ct�.�P-i Tr+1S t-fx.s /3C=t9J Goy-,.L- 44-CMrL> . 2. Cross-section C shows the proposed pan not matching the existing ground elevation at the property line. The off -site drainage should not be blocked. Please show swale C matching the existing ground elevation. RESPONSE: Tr+c O� =FEa g �v c 8 i'ae �w� o.� rt-rC aP-•••ate ,%,jl7 Trfa 71VI? or /-- !S oi.lL — O.O 3 f = 3V0 a p Ic7 SrFo�.�= No0 />E cy Jst L �p R l✓i._joR /frnE. 7 N1vA tiJ off= CP.—oZ 14 /-ie�p _rL .A_✓cY it i7LS Date: lUdeg �h Lam: iT/n h��9n'�G/d L P4iJgEa //4/7tP/ M M 1F YOU WE M REM COPIES OF REVISIONS �� �I Repat v09� �r5 /�on5o5' City of Fwrt Count 3. The UDSewer calculations do not match the proposed profile. A 16" pipe is modeled where a 15" pipe is shown on the plans. Please use the 100-year water surface elevation in the east pond as the tailwater elevation. RESPONSE: /(v' r? as /, e ,4 /2-iff r/rc-» 770 /S X c. ec S TrtL Z 1 � � 12 G1=1 Imp- pOJe4---� / �iiLr/✓i o.nJ �r liV„J 6 7•YIE:-: Anx GvulEt_ /••% 7- +t -Cr R I al p-.+�-f_)1 / S i �C� G,o!JJGi�Vr,T71/F 4. The property owners for lots 12 and 13 should be notified about remove their fences / outside the drainage easement. Please provide a copy of the notification letter to Stormwater. RESPONSE: 5. Please show the existing 60' contour on the grading plan. RESPONSE: Please refer to the redlined report and plans for additional review comments.7 r -.' and -r7+C Ti*r e-= i'a 192A oT 7 'C- fiV06,n rF ••�� ✓. s, I?4a F6,a_ 7t+c Epr-r /%..,a '7'C / NL l rFP- - ZS r,,•v. �. J itjerTl vt f s7 . r. 0 W U ¢as W 0� E5 W e� fiery z W� zg W Iir Hn 0 z Final Drainage Report .for Evergreen Park Second Filing Third Replat November 10, 1997 I. INTRODUCTION 1.1 Objective To provide a final drainage scheme for the proposed Evergreen Park Second Filing Third Replat based on master drainage planning developed by others. Specific objectives as part of this study are: 1. To adopt the drainage concepts contained in the Evergreen Park/ Greenbriar Outfall Drainage Basin Master Plan, 2. To consider the drainage schemes of all existing and proposed adjacent developments, 3. To consider any possible adverse effects downstream of Evergreen Park due to developed stormwater. 1.2 Mapping and Survernn A field survey of the site was conducted by King Sc Associates, Windsor, Colorado on Tuesday February 27, 1996. Based on this field survey information, topographic mapping was computer generated by King &- Associates with a contour interval of one (1) foot. 1.3 Site Reconnaissance Site visits were conducted on February 27 and March 22, 1996 by the project engineer. Based on the topographic mapping, existing drainage basins and land use were confirmed as well as existing structures and adjacent developments. The location and dimensions of existing culverts and storm inlets and pans were verified as well as their .. condition and flow direction. IL SITE LOCATION AND DESCRIPTION ij 2.1 Site Location The project is located in the Northeast Quarter of Section 1, Township 7 North, 1 Range 69 West of the 6th Principal Meridian in Fort Collins, Colorado. The project is bounded by Sugarpine Street on the west, Conifer Street on the south and North Lemay Avenue on the east. (See Vicinity Map). The most recent development in the area is Evergreen Park Second Filing Phase II to the west. 2.2 Site Description Evergreen Park Second Filing Third Replat is approximately 5.675 acres and is an infill site with existing residences surrounding the site on the north and east. Lots' 13-17 of Block 6 located west of the site, which are part of Phase 2 of the Second Filing, are in Final Drainage Report Evergreen Park Second Filing Third Replat November 10, 1997 Page 2 Northern Engineering Services, Inc. various stages of construction ranging from vacant to the completed model home on Lot 1.7. The site continuously receives fill from nearby construction sites and therefore the topography is no longer is its natural state and is continuously changing. Telephone pedestals are already located in the. utility easements and will require modification to raise them to proposed grades. Asphalt paving and curb and gutter from previous developments, terminate from the east and west with a 210- 245 foot void along Sitka Street to be completed as part of this project. The Third Replat includes Lots' 18-24 of Block 6 (on the north side of Sitka Street) and Lots' 1-8 of Block 7 (on the south side of Sitka Street) as shown on the Replat of Evergreen Park Second Filing. Lot 25 of Block 6 is owned by a private party and is not included in the proposed development. 2.3 Irrigation Ditches and Reservoirs There are no irrigation ditches or laterals currently on the site. III. HISTORIC DRAINAGE BASIN 3.1 Major Basin Description The site is located in the Evergreen Park/ Greenbriar Outfall Drainage Basin and is included in an on -going study by Lidstone &-Anderson, Inc. (L&A, Reference 1). The site is identified in the report as being located in Basin OA (See Exhibit 1). According to the draft Master Drainage Basin Plan by L&A, developed runoff from the Third Replat site is to be conveyed to the Evergreen East Detention Pond which is located near the southwest corner of Conifer Street and North Lemay Avenue. 3.2 Historic Drainage Patterns The site north of Sitka Street historically drains from northwest to southeast at slope of roughly 1.0% or less. Developed runoff from Phase 2 to the west enters the site along the west propertyline. Runoff also enters the site along the north propertyline from existing residences. The portion of the site south of Sitka Street historically drains from west to east at a slope of approximately 0.50% towards an existing three (3) foot concrete valley pan located 340 feet east (Existing Pan-2).. IV. DEVELOPED DRAINAGE BASIN 4.1 Developed Conditions The proposed land use for the site includes the following: • 18 Single Family Attached, Proposed improvements to the site include: Final Drainage Report Northern Engineering Services, Inc. Evergreen Park Second Filing Third Replat November 10, 1997 Page 3 • residential streets, • water and sanitary services. Two (2) lots will be added to Block 6 and one (1) lot will be added to Block 7 from the original plat. The site will require a replat to reflect these changes which will then be the Third Replat of Evergreen Park Second Filing. 4.2 Design Criteria and References Drainage criteria outlined in both the City of Fort Collins Storm Drainage Design Criteria Manual,(SDDCM) and Storm Drainage Criteria Manual by the Urban Drainage and Flood Control District have been referenced for this Final Drainage Study. 4.3 Llydrologic Criteria The Rational Method has been used to estimate peak stormwater runoff from the developed site. The initial 2-year and major 100-year design storms have been used in the evaluation of the proposed drainage system. Rainfall intensity data for the Rational Method has been taken from Figure 3-1 of SDDCM. 4.4 Hvdraulic Criteria The City of Fort Collins Storm Drainage Design Criteria has been referenced for all hydraulic calculations. In addition, the following computer programs will be utilized for final design: • The computer program "HY8" by the U.S. Department of Transportation, Federal Highway Administration, has been used to develop rating curves for existing and proposed sidewalk culverts; • The computer program "Flowmaster" will be used to analyze the capacity of open channels; • The computer program "UDSEWER" will be used to analyze the capacity of proposed Storm Sewer Line 1. 4.5 Drainage Conceit Developed stormwater from Evergreen Park Second Filing Third Replat will be conveyed overland to a proposed storm sewer system located approximately 390' east of the proposed site and, from there to the existing Evergreen East Detention Pond. Off -site stormwater from adjacent properties will also be routed to the existing detention facility. The City of Fort Collin's minimum design standards for culvert and swale capacities cannot be realized with this project and therefore variances will be required. Special design considerations are required as a result of existing topography and adjacent residences. Due to these circumstances, affording limited flexibility, drainage improvements such as sidewalk culverts and concrete pans have been sized to the maximum extent possible and will convey ' an increase in runoff due to development with minor deviation from historic water surface Final Drainage Report Northern Engineering Services, Inc. Evergreen Park Second Filing Third Replat November 10, 1997 Page 4 elevations. The primary objective in the design of the proposed drainage improvements is to disturb as few existing structures as possible and, at the same time provide a reasonable drainage solution. The Onsite Grading Plan for Evergreen Park Second Filing by Stewart &Associates reflects a change in drainage basins from those shown on Sheet 1 of the plan included in the master drainage study by Lidstone St. Anderson, Inc. (Reference 1). These changes are summarized on Exhibit 1 in the appendix (Section A) of this report. The net change is 14,918.381 square feet or 0.342 acres in additional drainage area being routed to Evergreen East Detention Pond . The engineer at Lidstone &-Anderson, Inc. who prepared the study was contacted in order to verify what impact if any this change would have on the detention ponds. Based on these discussions, it was concluded that this net change will not adversely effect the detention ponds. Where developed runoff leaves the site through adjacent properties, the flow is at or below historic rates (Design Points 2 and 5). The maximum 100-year developed runoff from Basin 5 (1.6 cfs) is less than that of historic basin H5 (3.2 cfs) due primarily to a change in area (See Exhibit 2, Section B). Stormwater runoff from this developed basin will follow the historic flow path to Pan 2 and then out to Conifer Street. The maximum 100- year developed runoff from Basin 2 (3.0 cfs) is slightly less than that of historic basin H2 ' (3.1 cfs) due primarily to a change in area (See Section B). Developed runoff will be conveyed to a historically low area located on Lot 25 where a proposed drywell will be located. Stormwater from the proposed site has ordinarily been conveyed to an existing 4' curb inlet and storm sewer system at the northwest corner of Conifer and Monterey Street. A storm sewer located approximately 390 feet east of the site has been proposed to intercept and route the increase in runoff due to the developed site. This storm sewer has been designed to intercept the difference in the 100-Year developed and historic rates or 25.6 cfs - �+ 12.7 cfs = 12.9 cfs. The approximate 100-year flow intercepted at Inlet 7 is 15.09 cfs (See I Section E). The 100-year spill which would occur at Inlet 7 is 10.51 cfs and would be conveyed to Conifer Street as it has historically. The existing 3 foot concrete valley pan (Pan 2) will be removed and replaced, at the same slope and alignment as the existing pan, following the construction of the proposed storm sewer line. IV. EROSION CONTROL 5.1 Erosion Control Plan Temporary sediment control consisting of two (2) curb and gutter gravel dikes will be used in Sitka Street. Silt fencing will also be required on the site south of Sitka Street and along the east property line as shown on the Grading and Erosion Control Plan. Final Drainage. Report Evergreen Park Second Filing Third Replat . November 10, 1997 Page 5 Northern Engineering Services, Inc. VI. CONCLUSIONS 6.1 Compliance with Standards All drainage analyses have been performed according to the City of Fort Collins Storm Drainage Design Criteria Manual (SDDCM) and the Urban Drainage and Flood Control District's Drainage Criteria Manual. A variance is requested for encroachment and freeboard requirements for pan flows at r cross -sections A -A, B-B, and C-C. e The Department of Energy has issued a license agreement which approves the Ts oot drainage easement designation within the U.S.B.R. easement (see Section I). A note also been added to the plat regarding fencing and landscaping restrictions within the drainage easement. The design of the drywell located adjacent to Lot 25 has been completed by Earth Engineering Consultants. Supporting documentation of this design can be found in Section J. Final Drainage Report Evergreen Park Second Filing Third Replat November 10, 1997 Page 6 Northern Engineering Services, Inc. REFERENCES Evaluation of the Impact of the Proposed Evergreen Park P.U.D., Second Filing Drainage Condition on Master Plan Detention Facilities, by Lidstone &-Anderson, Inc., August 19, 1993. 2. Final Drainage Report and Erosion Control Plan for Evergreen Park Second Filing Phase Two, TEC, The Engineering Company, August 1993. 3. Lemay Plaza/Evergreen East Detention Pond Evaluation, Lidstone &Anderson, Inc., March 7, 1996. 4. Storm Drainage Design Criteria and Construction Standards, City of Fort Collins, Colorado, May, 1984. 5. Drainage Criteria Maunal, Urban Drainage and Flood Control District, Wright -McLaughlin Engineers, Denver, Colorado, March, 1969. Final Drainage Report Evergreen Park Second Filing Thud Replat November 10, 1997 Page 7 Northern Engineering Services, Inc. APPENDIX PAGE Section A: Excepts from Master Plan and Evergreen East Detention Pond Evaluation ................................ Al- A9 Section B: Historic Hydrology.................................................................... B1- B8 Section C: Developed Hydrology.................................................................. Cl- C15 Section D: StreetCapacity............................................................................ D1- D6 Section E: Design of Inlets and Culverts...................................................... E1- E20 Section F: Existing and Proposed Pans ......................................................... F1- F20 Section G: Storm Sewer Design/ Riprap Calculations .................................. G1- G7 Section H: Erosion Control.................................................................... H1- H4 Section I: U.S.B.R. License Agreement....................................................... I1- 14 Section J: Lot 25 Drywell Design................................................................ J1- J3 c 0 c� rota a7y L 0 0 4-0 �c �o c E 0� L Q EVALUATION OF THE IMPACT OF THE PROPOSED EVERGREEN PARK P.U.D., SECOND FILING DRAINAGE CONDITION ON MASTER PLAN DETENTION FACILITIES SUBMITTED TO: R.J. Develco 605 South College Avenue Fort Collins, CO 80524 SUBMPITED BY: Lidstone & Anderson, Inc. 736 Whalers Way, F 200 Fort Collins, CO 80525 August 19, 1993 Introduction The Evergreen Park P.U.D. is a residential tract at various levels of development located in northeast Fort Collins located near the intersection of Conifer and Redwood Streets. The development is located in the Evergreen Park/Greenbriar Outfall Drainage Basin and is therefore subject to the conditions specified in the Master Drainage Plan for that basin [on -going study by LA, 1992-93]. A location map of the Evergreen Park study area is given in Figure 1. The Second Filing of the Evergreen Park P.U.D. straddles the boundary between Master Plan Basins 2 and OA. The drainage pattern for the Second Filing proposes to divert a portion of Basin 2 to Basin OA, and a portion of Basin OA to Basin 2. However, the proposed diversions do not constitute an equal exchange in drainage area. Consequently, it was recognized that there may be an impact to the Master Plan detention facilities. The detention facilities which are subject to being impacted by the proposed drainage pattern are the Redwood Pond (formerly Pond 2) at the intersection of Conifer and Redwood Streets, and the Evergreen East Pond (formerly Pond OA) near the intersection of Lemay Avenue and Conifer Street. The purpose of this study was to analyze the proposed drainage pattern in the context of the Master Plan in order to identify all impacts on the Master Plan detention facilities. The scope of this study was limited to the hydrologic analysis, using the EPA Stormwater Management Model [SWMM], of the proposed drainage condition. Proposed Drainage Plan The drainage plan proposed by The Engineering Company rI'EC] for the Evergreen Park P.U.D., Second Filing (Phases 1 and 2) is shown onFSheet 1. The Master Plan drainage basin boundaries in the vicinity of the Second Filing are superimposed on the TEC plan. As shown on Sheet 1, a 1.05-acre area along Foxtail Street is proposed to be diverted from Basin 2 to OA; a 2.74-acre area along Sugarpine Street is proposed for diversion from Basin OA to 2. Consequently, the drainage pattern would result in a net diversion of 1.69 acres from Basin OA to Basin 2. Hydrologic Analysis and Results of the Study The Master Plan SWMM model was modified to reflect the proposed basin area changes to Basins 2 and OA. Prior to the diversions, the areas of the two basins were both approximately 50 acres. Therefore, the diversions represent a net change in basin area of about 3.5 percent. 1 Since the total change in area is relatively small, the basin width and other parameters were not adjusted. The Master Plan SWMM model schematic for the southeast area of the Evergreen Park/Greenbriar Outfall Drainage Basin is given in Figure 2. The 100-year return period event was analyzed for the proposed condition and comparisons made to the Master Plan condition. A summary of the comparison between Master, Plan and proposed .Evergreen Park drainage conditions is provided in Table 1. The table indicates a slight increase in storage in the Redwood Pond and slight decrease in storage in the Evergreen East Pond. Correspondingly, the results reveal an increase of 0.3 cfs in the 100-year outflow from the Redwood Pond and a 0.2 cfs decrease in the 100-year discharge from the Evergreen East Pond. Since the outflows from these two ponds coalesce in an open channel before passing under Lemay Avenue, there is no net, impact to downstream facilities. The total downstream 100-year discharge in both cases is 45 cfs. The full SWMM output for the proposed condition is included at the end of this report. 1 2 "r- 4- <17 8 w z f� a�a Gi MIEN"/"- / i / , I o ---- Zoz W all S m I�IQvi�ll ' 9QC �� / • / y / / 1'/�, MM O 7 (// �l �'- // Z 12aK11 I �V• - /' i /yQ� /MQ/� W W m / / / - �� � p • IDi �.i My�� W I i I ii� / 9 I Io Z---- -- - o \l) I II _�L-------- m MUU / J \�\'Utay i _______ O0 M 04 EXHIBIT 1 y AS/ LEMAY PLAZA/EVERGREEN EAST -DETENTION POND EVALUATION PREPARED FOR: City of Fort Collins Stormwater Utility 235 Mathews 'Fort Collins, CO 80524 PREPARED BY: Lidstone & Anderson, Inc. 736 Whalers Way, F 200 Fort Collins, CO 80525 (LA Project No. COFC95.06) '••.• °. �0 RE L"+��� t� • ro���►��' March 7, 1996 HAI I .yid v dl-e- DATE PROJECT NO. 1129ht- 1�pFc95.�L DATE SHEET OF 7b I -I 41 z prZvlCX--VA-'l Ttr\r,aM!9:b -WA-n&14 QVTe%)Ca Fo¢ T"W T3mbia ca Cverd m,=m l 3. -ZELr2nc6eS t rg2c>l-, T5-4E ,3D And 1=,� T-� Tic C�xc;v�,.l Otis- �e.m Faz �Cs .5 Cb"t3 Aran dczvq/et� �fi�t�^,1I -ra -r++c l� •-+RV �a�t' r.,,.�„�,.1 -B�x S. -F7FG rto�i_ `51-��PF•'rla. IS Siia,�w1 �•� � He Fotia.11n�C �.tCrL RMFSVL" TS 7Z=Im4a, a CP. - 1i.1 Wt 1 QoF�B,wlt� 1�.Am,A Ct,A=zGc-i CAsr-lp u L"I.+ des I•41, hQ•FT IJS� _ 4156.0 .A--) / Table 1. Summary of Results for the Master Plan Detention Facilities. EZz 3Z 5 aim 1C IIA" VC A9/ 0 saaw 1A 4m1 2 aowass PC" OUTW CNYwtL orcorau ws Pam It amp to CKdtIM RIIAM row0 (Paws + - aunty w o rows 0 (PK N a) yaws Witt as atsw a LEGEND O"BASIN CNANNCL/PIPE O NODE Ell OCTIDMON POND/ ON -SITE MENTION "M "v 265 10 Cm Potts 04) 115 267 311 rawo wAv ro eat"" Aft TO �,qmy, smtut MC aurcAu amtn cwmn Figure 2. Schematic Diagram for the Hydrologic Model for Master Plan Conditions (Southeast Area). n u me./ EVERGREEN PARK/GREENBRIAR STORM DRAINAGE SOUTHEAST AREA 8/13/93 CLD LA,INC DEVELOPED CONDITION MASTER PLAN W/EVERGREEN PARK MODIFICATIONS 100-YEAR STORM PEAK FLOWS OF GUTTERS AND STORAGES OF RESERVOIRS "* CONVEYANCE PEAK STORAGE TIME ELEMENT (CFS) (AC -FT) (HR/MIN) 23 1. 3. 2 30. 24 1. 0. 2 30. 20 165. 0. 0 35. 21 4. 5. 2 10. 22 4. 0. 2 15. 37 313. 0. 0 40. 308 17. 9. 1 40. 263 17. 0. 1 45. 211 17. 0. 1 50. 212 273. 0. 0 40. 309 26. 8. 1 55. 311 13. 12. 1 55. 310 18. S. 1 25. 265 26. 0. 2 0. 268 13. 0. 2 0. 267 45. 0. 1 40. 0 0 L. 0 +r IN ml C 0 U N U) 1 e• � • •e ♦ N , r C�` • G� V ♦ f^ VVV ♦ C � LO mow Q. /1; r N � �♦ a w N N V 0.p P V ♦ r �� I , N ♦ � � / 00R • i �, i Vry No W W (V • � }m / ,, = i � / - WO W s N NSW- ♦ /W T. m LLI O _ .P� r14 W♦ ,` �� U �� �D�uu ❑: 'l i � � W 'atti P. W ••� a`O� . r N Z ?'o as �/ 19���111 R�Zz xj M m IA \ w \\Sg jW 1Nbpy^ \\ N \ ` o r P 9 YJO O � N J m � 3 �� �O O v! N \P w m � iwZo� N N a - n�T W� L�TI - - �'❑W nW - f r HISTORIC HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNTH2.WOl 19-Jun-97 Ca1c Bv:mbw DESIGN POINT H2: (Includes Basins H2 & H11) TOTAL AREA = A (ac)= 1.966 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.1100 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.0000 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 1.8560 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.25(1.856)+ 0.95(0.110) = 0.29 1.966 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: SWALE FLOW: T2 = 1.87 (1.1 - CCf) SQRT(L) = 28.5 min L (ft)= 400 CUBRT(S) S (%) = 66.9-60.3 = 1.65 T100 = 1.87 (1.1 - CCf) SQRT(L) = 26.9 min 400 CUBRT(S) C = 0.20 L (ft)= 62 S(%)= 60.3-60.0= 62 V(fps) = 1.00 0.48 Tt = 2-YEAR TIlvIE OF CONCENTRATION; Tc2 = 29.5 rein 100-YEAR TINE OF CONCENTRATION; Tc100 = 27.9 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.49 i100(in/hr)= 4.34 Q2(cfs) = CCf x i2 x A =0.8 Q100(cfs) = CCf x i100 x A = 3.1 L = 1.0 60(v) No Text 134/ HISTORIC HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNTH5.WQ1 05-Apr-96 Calc DESIGN POINTH5: (Includes Basin H5) TOTAL AREA = A (ac)= 2.165 RUNOFF COEFFICIENTS: (From Table 3-3) . Impervious Area/ Lot(ac)= 0.0000 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.0000 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 2.1650 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.25(2.165) = 0.25 2.165 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: T2 = 1.87 (1.1 - CCf) SQRT(L) = 18.8 min L (ft)= 155 CUBRT(S) S (%) = 62.16-60.0 = 1.39 T100 = 1.87 (1.1 - CCf) SQRT(L) = 17.7 min 155 CUBRT(S) C = 0.20 SWALE FLOW: L (ft)= 446 S (%) = 60.0 - 58.61 = 446 V(fps) = 1.15 2-YEAR TIME OF CONCENTRATION; Tc2 = 100-YEAR TIME OF CONCENTRATION; Tc100 = RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.62 Q2(cfs) = CCf x i2 x A = 0.9 QI00(cfs) = CCf x i100 x A = 3.2 Tt = L = 6.5 min I 0.31 60(V) 25.2 min 24.2 min i100(in/hr)= 4.68 1 1 1 1 1 1 1 1 i35/ HISTORIC HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNTH7.WQ1 24-Apr-96 . Cale DESIGN POINT H7: (Includes Basin 147) TOTAL AREA = A (ac)= 7.478 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.7180 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.8090 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 5.9510 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.718+0.809)+0.25(5.951) 0.39 7.478 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: T2 = 1.87 (1.1 - CCf) SQRT(L) = 36.8 min L (ft)= 453 CUBRT(S) S (%) = 64.92-60.7 = 0.92 T100 = 1.87 (l.l - CCf) SQRT(L) = 34.8 min 453 CUBRT(S) C = 0.20 GUTTER FLOW: L (ft)= 489 Tt = L = 6.0 min S (%) = 60.75 - 58.76 = 0.41 60(V) 489 V(fps) = 1.35 2-YEAR TIME OF CONCENTRATION; Tc2 = 42.9 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 40.8 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.16 i100(in/hr)= 3.47 Q2(cfs) = CCf x i2 x A = 3.4 Q100(cfs) = CCf x i100 x A = 12.7 HISTORIC HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO.. File Number: DSNPTHIO.WQI DESIGN POINT H10: (Includes Basins' H5, H7 & H10) TOTAL AREA = A (ac)= 13.652 Area RUNOFF COEFFICIENTS: Basin H5= 2.1650 Composite c= Basin H7 = 7.4780 Composite.c = Basin H10 = 4.0090 Composite c= COMPOSITE RUNOFF COEFFICIENT: 0.25 0.39 0.46 Calc C = 2.165(0.25) +7.478(0.39) +4.009(0.46) = 0.39 13.652 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) From Calculations for Design Point H7: T2 = 42.9 T100 = 40.8 GUTTER FLOW: (Down Existing Pan 2) L (ft)= 228.87 Tt = L = 2.9 S (%) = 58.76 - 57.80 = 0.42 60(V) 228.87 V(fps) = 1.32 GUTTER FLOW: (Down North Flowline of Conifer to Proposed Inlet) L (ft)= 255 TI = L = 3.0 S (%) = 57.80 - 56.58 = 0.48 60(V) 255 V(fps) = 1.40 2-YEAR TIME OF CONCENTRATION; Tc2 = 48.8 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 46.7 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.07 i100(in/hr)= 3.16 Q2(cfs) = CCf x i2 x A = 5.7 QI00(cfs) = CCf x HOO x A = 20.9 min I min I � ♦ r ^ u w O II J W r e � a ♦ � W x 2 0 0 V It W♦ - f 96ti� a Y J W W o J W ' ••� � c� W o v Z • r�v 40 (n 10mIT o U • pl ! N n C(vJ clf Z,,, _ Lrj m / X �ZZ WU-- X _ W] M v CIN El 0. 7 13 9� HISTORIC HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPTHII.WB2 19-Jun-97 Calc DESIGN POINT HI 1: (Includes Basin HI l) TOTAL AREA = A (ac)= 0.961 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.0000 C for Roofs = . 0.95 Area of Streets and Walks(ac)= 0.0000 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.9610 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.25(0.961) = 0.25 0.961 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: SWALE FLOW: L (ft)= 202 S (%) = 65.4-61.33= 202 C = 0.25 L (ft)= 66 S(%)= 61.33-61.25= 66 V(fps) = 0.90 T2 = 1.87 (1.1 - CCf) SQRT(L) = 17.9 min CUBRT(S) 2.01 T100 = 1.87 (1.1 - CCf) SQRT(L) = 16.6 min CUBRT(S) 0.12 Tt = 2-YEAR TIlAE OF CONCENTRATION; Tc2 = 19.1 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 17.8 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.89 i100(in/hr)= 5.55 Q2(cfs) = CCf x i2 x A =0.5 Q100(cfs) = CCf x i100 x A = 1.7 L = 1.2 min 60(V) _0 0 L. N a _0 U c 0 U N DEVELOPED HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNT-1.WQ1 04-Apr-96 Calc DESIGN POINT 1: (Includes Basin 1) TOTAL AREA = A (ac)= 1.541 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.2610 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.3380 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.9420 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.261+0.338)+0.25(0.942) = 0.52 1.541 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: L (ft)= 192 S (%) = 66.9-62.0 = 2.55 192 C = 0.25 GUTTER FLOW: L (ft)= 148 S (%) = 62.0 - 61.11 = 0.60 148 V(fps) = 1.55 2-YEAR TIME OF CONCENTRATION; Tc2 = 17.7 100-YEAR TIME OF CONCENTRATION; Tc100 = 16.5 RAINFALL INTENSITY: T2 = 1.87 (1.1 - CCf) SQRT(L) = 16.1 CUBRT(S) T100 = 1.87 (1.1 - CCf) SQRT(L) = 14.9 CUBRT(S) Tt = min min FROM FIGURE 3-1: i2(in/hr)= 1.98 i100(in/hr)= 5.73 Q2(cfs) = CCf x i2 x A = 1.6 Q100(cfs) = CCf x i100 x A = 5.8 L = 1.6 60(V) G!/ min I min I GZ DEVELOPED HYDROLOGY' Evergreen Park, Second Filing, Fort. Collins, CO. File Number: DSNPNT-2. WB2 DESIGN POINT 2: (Includes Basin 2 & 11) TOTAL AREA = A (ac)= 1.528 1❑ Calc RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.1100 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.0000 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 1.4180 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.11)+0.25(1.418) = 0.30 1.528 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: T2 = 1.81(1.1 - CCf) SQRT(L) = 14.0 L (ft)= 168 CUBRT(S) S (%) = 66.9-61.58= 3.17 T100 = 1.87 (1.1 - CCf) SQRT(L.) 13.0 168 CUBRT(S) C = 0.25 min min GUTTER FLOW: (Down Swale 1) L (ft)= 447 Tt = L = 6.2 min S (%) = 61.58 - 60.0 = 0.35 60(V) 447 . V(fps) = 1.20 2-YEAR TIME OF CONCENTRATION; Tc2 = 20.2 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 19.2 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.81 i100(in/hr)= 5.30 Q2(cfs) = CCf x i2 x A =0.8 Q100(cfs) = CCf x i100 x A = 3.0 C 3 / DEVELOPED HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNT4.WQ1 01-May-97 Calc DESIGN POINT 4: (Includes Basin 4) TOTAL AREA = A (ac)= 1.313 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.4230 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.3050 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.5850 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.423+0.305)+0.25(0.585) = 0.64 1.313 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: T2 = 1.87 (1.1 - CCf) SQRT(L) = 11.6 min L (ft)= 90 CUBRT(S) S (%) = 65.3-63.3 = 2.20 T100 = 1.87 (1.1 - CCf) SQRT(L) = 10.7 min 90 CUBRT(S) C = 0.25 GUTTER FLOW L (ft)= 490 S (%) = 62.72 - 60.26 = 0.50 490 V(fps) = 1.43 2-YEAR THAE OF CONCENTRATION; Tc2 = 17.3 100-YEAR TIME OF CONCENTRATION; T000 = 16.5 RAINFALL INTENSITY: Tt = L = 5.7 60(V) min min FROM FIGURE 3-1: i2(in/hr)= 1.99 i100(in/hr)= 5.73 Q2(cfs) = CCf x i2 x A =1.7 Q100(cfs) = CCf x i100 x A = 6.0 min DEVELOPED HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNT-5.WO1 01-May-97 Calc DESIGN POINT 5: (Includes Basin 5) TOTAL AREA = A (ac)= 1.443 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.0000 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.0000 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 1.4430 C for Lawn = 0.20 COMPOSITE RUNOFF COEFFICIENT: C = 0.20(1.443) = 0.20 1.443 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: T2 = 1.87 (1.1 - CCf) SQRT(L) = 29.2 min L (ft)= 420 CUBRT(S) S (%) = 65.5-58.61= 1.64 T100 = 1.87 (1.1 - CCf) SQRT(L) = 27.6 min 420 CUBRT(S) C = 0.20 SWALE FLOW: L (ft)= 0 S (%) = 62.0 - 58.61 = ERR 0 V(fps) = 1.36 2-YEAR TIME OF CONCENTRATION; Tc2 = 29.2 100-YEAR TMIE OF CONCENTRATION; Tc100 = 27.6 RAINFALL INTENSITY: Tt = L = 0.0 60(V) min min FROM FIGURE 3-1: i2(in/hr)= 1.49 i100(in/hr)= 4.38 Q2(cfs) = CCf x i2 x A =0.4 Q 100(cfs) = CCf x i 100 x A= 1.6 mini 1 1 1 1 1 1 1 1 1 DEVELOPED HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNT-6.WQI 11-Mar-97 Calc DESIGN POINT 6: (Includes Basins' 1-3, & 6) TOTAL AREA = A (ac)= 5.888 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.9140 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.8570 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 4.1170 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.914+0.857)+0.25(4.117) = 0.46 5.888 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) From Calculations for Design Point 1: T2 = 17.7 T100 = 16.5 GUTTER FLOW: L (ft)= 504 Tt = S (%) = 61.11 - 58.87 = 0.44 504 V(fps) = 1.38 2-YEAR TRVIE OF CONCENTRATION; Tc2 = 23.8 min 100-YEAR TIlAE OF CONCENTRATION; Tc100 = 22.6 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.68 Q2(cfs) = CCf x i2 x A =4.6 Q100(cfs) = CCf x i100 x A = 16.4 i100(in/hr)= 4.85 c.51 L = 6.1 min I 60(v) DEVELOPED HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNT7.WB2 01-May-97 DESIGN POINT 7: (Includes Basins' 4 & 7) TOTAL AREA = A (ac)= 2.201 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.7020 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.6140 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.8850 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.702+0.614)+0.25(0.885) = 0.67 2.201 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) From Calculations for Design Point 4: T2 17.3 T100 = 16.5 GUTTER FLOW: L (ft)= 287 Tt = L = 3.3 min S (%) = 60.26 - 58.76 = 0.52 60(V) 287 V(fps) = 1.43 2-YEAR TIME OF CONCENTRATION; Tc2 = 20.6 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 19.8 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.82 i100(in/hr)= 5.23 Q2(cfs) = CCf x i2 x A =2.7 Q100(cfs) = CCf x i100 x A = 9.6 DEVELOPED HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNT7a.WQ1 01-May-97 Calc DESIGN POINT 7: (Includes Basins' 1-4, 6,& 7) TOTAL AREA = A (ac)= 8.089 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 1.6160 C for Roofs = 0.95 Area of Streets and Walks(ac)= 1.4710 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 5.0020 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(1.616+1.471)+0.25(5.002) = 0.52 8.089 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor, Storm Return Period of 100- Years) From Calculations for Design Point 6: T2 = 23.8 T100 = 22.6 GUTTER FLOW: L (ft)= 0 Tt = S (%) = 60.26 - 58.76 = ERR V(fps) = 0.00 2-YEAR TIME OF CONCENTRATION; Tc2 = 23.8 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 22.6 min RAINFALL INTENSITY: . . FROM FIGURE 3-1: i2(in/hr)= 1.70 i100(in/hr)= 4.89 Q2(cfs) = CCf x i2 x A =7.1 Q100(cfs) = CCf x i100 x A = 25.6 L = ERR min 60(V) DEVELOPED HYDROLOGY. Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNT-8.WQI I I -Mar-97 Calc DESIGN POINT 8: (Includes Basin 8) TOTAL AREA = A (ac)= 0.481 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.0000 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.4650 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.0160 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.465)+0.25(0.016) = 0.93 0.481 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: T2 = 1.87 (1.1 - CCf) SQRT(L) = 3.8 min L (ft)= 10 CUBRT(S) S (%) = .62.1-61.8 = 2.70 T100 = 1.87 (1.1 - CCf) SQRT(L) = 3.6 min 10 CUBRT(S) C = 0.20 GUTTER FLOW: L (ft)= 423 Tt = L = 5.0 min S (0/,) = 61.3 - 59.39 = 0.46 60(V) 423 V(fps) = 1.40, 2-YEAR TIME OF CONCENTRATION; Tc2 = 8.9 min 100-YEAR TIME OF CONCENTRATION; TcI00 = 8.6 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(itVhr)= 2.62 HOO(inlbr)= 7.15 Q2(cfs) = CCf x i2 x A =1.2 Q100(cfs) = CCf x i100 x A = 3.4 Gam+ DEVELOPED HYDROLOGY Evergreen Park, Second Filing; Fort Collins, CO. File Number: DSNPNT-9.WQ1 04-Apr-96 Calc DESIGN POINT 9: (Includes Basin 9) TOTAL AREA = A (ac)= 0.312 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.0310 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.1410 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.1400 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.95(0.031+0.141)+0.25(0.140) = 0.64 0.312 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: T2 = 1.87 (1.1 - CCf) SQRT(L) = 10.5 min L (ft)= 79 CUBRT(S) S (%) = 65.0-63.08 = 2.43 T100 = 1.87 (1.1- CCf) SQRT(L) = 9.7 min 79 CUBRT(S) C = 0.25 GUTTER FLOW: L (ft)= 81 Tt = L = 0.6 min S (%) = 62.58 - 61.60 = 1.21 60(V) 81 V(fps) = 2.20 2-YEAR TIME OF CONCENTRATION; Tc2 = 11.1 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 10.4 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 2.40 i100(in/hr)= 7.09 Q2(cfs) = CCf x i2 x A = 0.5 Q100(cfs) = CCf x i100 x A = 1.8 I DEVELOPED HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPT-l0.WQ1 24-Aor-96 Calc DESIGN POINT 10: (Includes Basins' 1-8 & 10) TOTAL AREA = A (ac)= 13.553 Area RUNOFF COEFFICIENTS: Basins' 1-4,6,7= 7.8790 Composite c= 0.52 .Basin 5 = 1.5310 Composite c = 0.26 Basin 8 = 0.6060 Composite c= 0.79 Basin 10= 3.5370 Composite c= 0.39 COMPOSITE RUNOFF COEFFICIENT: C = 7.879(0.52)+1.531(0.26)+0.606(0.79)+ = 0.47 13.553 Cf = 1.00 (Frequency Adjustment Factor; Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) From Calculations for Design Point 7: 72 = 23.8 T100 = 22.6 GUTTER FLOW: (Down Proposed Pan 2) L (ft)= 228.95 Tt = L = 2.9 S (%) = 58.76 - 57.80 = 0.42 60(V) 228.95 V(fps) = 1.32 GUTTER FLOW: (Down North Flowline of Conifer to Proposed Inlet) L (ft)= 255 Tt = . L = 3.0 S (%) = 57.80 - 56.58 = 0.48 60(V) 255 V(fps) = 1.40 2-YEAR TIME OF CONCENTRATION; Tc2 = 29.7 min 100-YEAR TIME OF CONCENTRATION; Tc100 = 28.5 min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 1.48 i100(in/hr)= 4.30 Q2(cfs) = CCf x i2 x A = 9.4 Q100(cfs) = CCf x i100 x A = 34.1 Gio/ min I min DEVELOPED HYDROLOGY Evergreen Park, Second Filing, Fort Collins, CO. File Number: DSNPNTII.WB2 DESIGN POINT 11: (Includes Basin 11) Gi i 01=May-97 Calc By:MBR TOTAL AREA = A (ac)= 0.758 RUNOFF COEFFICIENTS: (From Table 3-3) Impervious Area/ Lot(ac)= 0.0000 C for Roofs = 0.95 Area of Streets and Walks(ac)= 0.0000 C for Concrete = 0.95 Area of Gravel Parking (ac)= 0.0000 C for Gravel = 0.50 Area of Lawn (ac)= 0.7580 C for Lawn = 0.25 COMPOSITE RUNOFF COEFFICIENT: C = 0.25(0.758) = 0.25 0.758 Cf = 1.00 (Frequency Adjustment Factor, Storm Return Period of 2- Years) Cf = 1.25 (Frequency Adjustment Factor; Storm Return Period of 100- Years) OVERLAND FLOW: T2 = 1.87 (1.1 - CCf) SQRT(L) = 14.0 min L (ft)= 168 CUBRT(S) S (%) = 66.9-61.58= 3.17 T100 = 1.87 (1.1 - CCf) SQRT(L) = 13.0 min 168 CUBRT(S) C = 0.25 GUTTER FLOW: (Down Swale 1) L (ft)= 144 Tt = L = 2.4 min S (%) = 61.53 - 61.17 = 0.25 60(V) 144 V(fps) = 1.00 2-YEAR TIME OF CONCENTRATION; Tc2 = 16.4 min 100-YEAR TDAE OF CONCENTRATION; Tc 100 = 15.4 . min RAINFALL INTENSITY: FROM FIGURE 3-1: i2(in/hr)= 2.03 i100(in/hr)= 5.94 Q2(cfs) = CCf x i2 x A =0.4 Q100(cfs) = CCf x i100 x A = 1.4 r, J ^' _Q Z C! - W No C N W U Z W I II J ( L (!l 0 J Q o U) vi m QO _ c J 00 00 00 LLL U C C N LU L ii � ui 0 0 ? L`o_WY o�'-J Q Jco o Q � Q �ao� 3Nn ua3d06d I I o O W ZI J � W I O f 4 J 1 a ? G z •3 3 `I w t ' e• . ..� I 3Nn 1U?J3dO6d I - 0 w m w 0 a N W� m 0 C K W Q o V �J0 N cr W V 1 LLI a ZNn m W Z N w E5 s ow Z N a .......l ■■■■■■■ ■■■■.■■ No Text GrV ''V^) . v/ J Z N Q W z N V5 O o LL C U O� 0 M U Oz Z L a L w r I Z cM W V)Z W U m LL c a W Li O a U Z 1. Of IL � O� Z� Mt V) I : N _Z Q J J O O W O c 0 L O J Z O a Q U Z Y W < H H Q J W J Q W U = V) O Q� W Q V CD w c V) V> I I� O I O I O l O V) 6 V O U Z V a v c w 4 i V a c W J% L J 1 Lj V) Li Q V) Z In Z LL Q V) 3 3 Q Q J J r C 0 U TAP -LE 4-1 INITIAL STORM -. STREET RUNOFF ENCROACHMENT street C1asaNscatlon Maxhn Enaroechment LOCAL (Includes places alleys No curb -overtopping. *Flow may spread to marginal access) crown of street. COLLECTOR No curb -overtopping. `Flow spread must leave at least one lane width free of water. MAJOR ARTERIAL No curb -overtopping. `Flow spread must leave at least one-half of roadway width free of water in each direction- * Where no curb overtopping exists, encroachment shall not extend over property lines. TABLE 4-2 MAJOR STORM - STREET RUNOFF ENCROACHMENT Street ClseeNlondon Maxkn En clxnent LOCAL (Includes places, alleys Residential dwellings, public, marginal access. & collector) commercial and industrial buildings shall not be inundated at the ground line unless buildings are flood -proofed. The depth of water over the crown shall not exceed six (6) inches. MAJOR ARTERIAL Residential dwellings, public, commercial and industrial buildings shall not be inundated at the ground line unless buildings are flood -proofed. Depth of water at the street crown shall not exceed six (6) inches to allow operation of emergency vehicles. The depth of water over the hutter flowline shall not exceed 18 inches. In some cases, the 18 inch depth over the gutter flowline is more restrictive than the 6 inch depth over the street crown. For these conditions, the most restrivtive of the two criteria shall govern. 1- Z cW f U N 'Q a0 4Z Q W aW N F dl m W F Q 0 J J Q o� Ov O 0 v� a� m II e� o u 0° � O e0 .p Ov p 96 a E owv E 9 a O y o BY a �+o �.°Z!� eC� > Cry w 0. e o U Q O ,- a O WW >1F Az L y ae.[y cvA Upp nYn boo 0 o r II II h "v O 00 O� OO R 1l a0 O O II � II RfV C OCG C.i u m - 3 > 3 U a II U LLI � u u '• uF a U "� V ur p A a a a h a Q .J ¢ Q u AAA <S ��C7 N Lrw;a m MX< Q u3 f% Q Z p a a pW.0. O ONO ONO h O � w M 00 p� DD p, R M a en.+�.+� hm LT.e n r 00 r 00 h h OcqG h G M C7 M M h C M C t::) Z/ » 3/ N C Iv y O o� 0 ZN I I t U fA C A 9 v o O 0 m� o II 3 m A o a e "� o•go3 G u OZ E �eNn AZ ;oo ? rD5 0 gQ 0 0 II II N va���vri. F F II I up ^ nnQ , p" a i 3 U {7,7 II B ° E ee ee c in .. N H a C7 W o. 0 0 0 0 c°v � a R L t d G G 3 3 II II c O o �No Gco ago LO ow3 �o v j 4 O aN0 0000 tM�f Q (V O�NO�Nt�i fV C U h O d Liz VV�� M 0 00 h N ua. O 0�~0 00 O O o'o o�o� o0 3NN'A rInNNy;. 4/ a � cn v z fl O F F N 3 UUQ > `o dam o o e [L U U O Y Y W A q Y Y O Y e 9 � y opII '- ,oe t+ b0 o C 3 S cc 00 � U � 91. o 8 Ln do uU.. z vl aC� Vj?G "" O c�ensG O � C Q 6 y ry U ��tpp {j�c7. u o a a z e r U Wcc z C oo� a b\ II aW. geMnm�e w M M � rv, ) �CY2° S ` ) |S! ( 0 � § ¢ t ƒ /§ < \) s £ u! !e E § /\]�§m§ $§} k � ^ ` . 7f� §[!!�3 �2» C)ca< � •�a;&.a !|___}ƒ/ t!§ U\� \ CL. \}k{! § /§ - q )§ � � . 1.0 .9 .8 .7 .3 .2 .I .0 SLOPE OF OUTER (T.) REDUCTION FACTOR. F 0.60 0.80 0.55 0.725 0.50 0.65 0.45 0.575 0.40 0.50 milli 11111111 NE11111111111 � WII�1�1 II1i1111Y1111111 I���l1�111■11 0 21 4 6- 8 10 12 14 SLOPE OF GUTTER Figure 4-2 REDUCTION FACTOR FOR ALLOWABLE GUTTER CAPA.;ITY Apply reduction factor for applicable slope to the theoretical gutter capacity to obtain allowable gutter capacity. REFERENCE: U.S. DEPARTMENT OF COMMERCE BUREAU OF PUBLIC ROADS. 1965. U) L U c M 0 a) c 0 c 0 W c 0 U N U) 1 E,j F�,r�,z-E G ter Z5 1 Proposed 4' Metal Sidewalk Culvert 1 at Design Point 2 2-Year Design -Flow = 0.8 cfs CURRENT DATE: 04-08-1996 FILE DATE: 04-08-1996 CURRENT TIME: 10:08:13 FILE NAME: EVGPROPI FHWA CULVERT ANALYSIS HY-8,. VERSION 4.1 C SITE DATA CULVERT SHAPE, MATERIAL, INLET U L INLET OUTLET CULVERT BARRELS V ELEV. ELEV. LENGTH SHAPE SPAN RISE MANNING INLET (FT) (FT)- (FT) MATERIAL (FT) (FT) n TYPE 1 4960.27 4960.26 5.17 1 RCB 4.00 0.24 .013 CONVENTIONAL 2 3 4' 5 6 SUMMARY OF CULVERT FLOWS (CFS) FILE: EVGPROPI DATE: 04-08-1996 ELEV (FT) TOTAL 1 2 3 4 5 6 ROADWAY ITR 4960.40 0.0 0 0 0 0 0 0 0 1 4960.41 0.1 0 0 0 0 0 0 0 1 4960.41 0.2 0 0 0 0 0 0 0 1 4960.42 0.3 0 0 0 0 0 0 0 1 4960.42 0.4 0 0 0 0 0 0 0 1 4960.42 0.5 1 0 0 0 0 0 0 1 4960.43 0.6 1 0 0 0 0 0 0 1 4960.44 0.7 1 0 0 0 0 0 0 1 4960.45 0.8 1 0 0 0 0 0 0 26 4960.47 0.9 1 0 0 0 0 0 0 30 4960.49 1.0 I 0 0 0 0 0 0 30 4960.51 1.0 1 0 0 0 0 O.OVERTOPPING 2-Year Design Flow = 0.8 cfs at Design Point 2 Top Back of Walk Elevation= 4960.51 = Spill Elevation SUMMARY OF ITERATIVE SOLUTION ERRORS FILE: EVGPROPI DATE: 04-08-1996 HEAD HEAD TOTAL FLOW $ FLOW ELEV(FT) ERROR(FT) FLOW(CFS) ERROR(CFS) ERROR 4960..40 0.00 0 0 0.00 4960.41 0.00 0 0 0.00 4960.41 0.00 0 0 0.00 4960.42 0.00 0 0 0.00 4960.42 0.00 0 0 0.00 4960.42 0.00 1 0 0.00 4960.43 0.00 1 0 0.00 4960.44 0.00 1 0 _ 0.00 4960.45 0.00 1 0 7.83 4960.47 -0.00 1 0 17.91 4960.49 -0.00 1 0 26.12 <1> TOLERANCE (FT) = 0.010 <2> TOLERANCE ($) = 1.000 CURRENT DATE: 04-08-1996 CURRENT TIME: 10:08:13 aZ/ 2 FILE DATE: 04-08-1996 FILE NAME: EVGPROPI PERFORMANCE CURVE FOR CULVERT # 1 - 1 ( 4 BY .24 ) RCB DIS- HEAD- INLET OUTLET CHARGE WATER CONTROL CONTROL FLOW NORMAL CRITICAL OUTLET TAILWATER FLOW ELEV. DEPTH DEPTH TYPE DEPTH DEPTH -VEL. DEPTH VEL. DEPTH (cfs) (ft) (ft) (ft) <F4> (ft) (ft) (fps) (ft) (fps) (ft) 0.0 4960.40 0.00 0.13 0-NF 0.00 0.00 0.00 0.00 0.00 0:14 0.1 4960.41 0.04 0.14 3-M1t 0.04 0.03 0.18 0.14 0.00 0.14 0.2 4960.41 0.06 0.14 3-Mlt 0.06 0.04 0.36 0.14 0.00'.0.14 0.3 4960.42 0.08 0.15 3-Mlt 0.08 0.06 0.54 0.14 0.00 0.14 0.4 4960.42 0.10 0.15 3-Mlt 0.10 '0.07 0.71 0.14 0.00 0.14 0.5 4960.42 0.12 0.15 3-Mlt 0.11 0.08 0.89 0.14 0.00 0.14 0.6 4960.43 0.13 0.16 3-Mlt 0.12 0.09 1.07 0.14 0.00 0.14 0.7 4960.44 0.15 0.17 3-Mlt 0.14 0.10 1.25 0.14 0:00 0.14 0.8 4960.44 0.15 0.17 3-Mlt 0.14 0.10 1.32 0.14 0.00 0.14 0.9 4960.44 0.15 0.17 3-Mlt 0.14 0.10 1.32 0.14 0.00 0.14 1.0 4960.52 0.15 0.25 3-M2t 0.14 0.10 1.32 0.14 0.00 0.14 El. inlet face invert 4960.27 ft El. outlet invert 4960.26 ft El. inlet throat invert 0.00 ft El. inlet crest 0.00 ft ***** SITE DATA ***** CULVERT INVERT ************** INLET STATION (FT) 0.00 INLET ELEVATION (FT) 4960.27 OUTLET STATION (FT) 5.17 OUTLET ELEVATION (FT) 4960.26 NUMBER OF BARRELS 1 SLOPE (V-FT/H-FT) 0.0020 CULVERT LENGTH ALONG SLOPE (FT) 5.17 ***** CULVERT DATA SUMMARY ************************ BARREL SHAPE_ BOX BARREL SPAN _ 4.00 FT BARREL RISE 0.24 FT BARREL MATERIAL CONCRETE BARREL MANNING'S N 0.013 INLET TYPE CONVENTIONAL INLET EDGE AND WALL BEVELED EDGE (1.5:1) INLET DEPRESSION NONE 3 CURRENT DATE: 04-08-1996 FILE DATE: 04-08-1996 CURRENT TIME: 10:08:13 FILE NAME: EVGPROPI' TAILWATER CONSTANT WATER SURFACE ELEVATION 4960.40 ROADWAY OVERTOPPING DATA ROADWAY SURFACE. PAVED EMBANKMENT TOP WIDTH (FT) 5.00 CREST LENGTH (FT) 100.00 OVERTOPPING CREST ELEVATION (FT) 4960.51 Existing 2' Metal Sidewalk Culvert 2 Historic 2-Year Flow-- 3.5 cfs CURRENT DATE: 04-10-1996 CURRENT TIME: 11:13:50 FHWA CULVERT ANALYSIS HY-8, VERSION 4.1 FILE DATE: 04-07-1996 FILE NAME: EVG-EXST C. U SITE DATA CULVERT SHAPE, MATERIAL, INLET L INLET OUTLET CULVERT BARRELS V ELEV. ELEV. LENGTH SHAPE SPAN RISE MANNING INLET (FT) (FT) (FT) MATERIAL (FT) (FT) n TYPE 1 4958.76 4958.73 .5.17 1 RCB 2.00 0.24 .013 CONVENTIONAL 2 3 4 5 6 SUMMARY OF CULVERT FLOWS (CFS) FILE: EVG-EXST DATE: 04-07-1996 ELEV (FT) TOTAL 1 2 3 4. 5 6 ROADWAY ITR 4958.76 0.0 0 0 0 0 0 0 0 1 4958.95 0.5 1 0 0 0 0 0 0 1 4959.09 1.0 1 0 0 0 0 0 0 1 4959.27 1.5 2 0 0 0 0 0 0 1 4959.32 2.0 2 0 0 0 0 0 0 30 4959.36 2.5 2 0 0 0 .' 0 0 1 29 4959.38 3.0 2 0 0 0 0 0 1 18 4959.40 3.5 2 0 0 0 0 0 2 15 4959.41 4.0 2 0 0 0 0 0 2 13 4959.42 4.5 2 0 0 0 0 0 3 11 4959.43 5.0 2 0 0 0 0 0 3 10 4959.28 1.5 2 0 0 0 0 0 OVERTOPPING Existing 2-Year Flow-- 3.5 cfs SUMMARY OF ITERATIVE SOLUTION ERRORS FILE: EVG-EXST DATE: 04-07-1996 HEAD' HEAD TOTAL FLOW % FLOW ELEV(FT) ERROR(FT) FLOW(CFS) ERROR(CFS) ERROR 4958.76 0.00 0 0 0.00 4958.95 0.00 1 0 0.00 4959.09 0.00 1 0 0.00 4959.27 0.00 2 0 0.00 4§59.32 -0.00 2 0 12.66 4959.36 0.00 3 0 1.82 4959.38 0.00 3 0 1.71 4959.40 0.00 4 0 1.56 4959.41 0.00 4 0 1.43 4959.42 0.00 5 0 1.24 4959.43 -0.00 5 0 0.90 <1> TOLERANCE (FT) = 0.010 <2> TOLERANCE (%) = 1.000 4F-Sl 2 CURRENT DATE: 04-10-1996 FILE DATE: 04-07-1996 CURRENT TIME: 11:13:50 FILE NAME: EVG-EXST PERFORMANCE CURVE FOR CULVERT # 1 - 1 ( 2 BY .24 ) RCB DIS- HEAD- INLET OUTLET CHARGE WATER CONTROL CONTROL FLOW NORMAL CRITICAL OUTLET TAILWATER FLOW ELEV. DEPTH DEPTH TYPE DEPTH DEPTH VEL. DEPTH VEL. DEPTH (cfs) (ft) (ft) (ft) <F4> (ft) (ft) (fps) (ft) (fps) (ft) 0 4958.76 0.00 0.00 0-NF 0.00 0.00 0.00 0.00 0.00 -0.26 1 4958.95 0.19 0.19 1'-S2n 0.12 0.13 2.01 0.12 1.72 0.07 1 4959.09 0.33 0.33 5-S2n 0.19 0.20 2.59 0.19 1.89 0.12 2 4959.27 0.51 0.47 6-FFn 0.24 0.24 3.13 0.24 2.03 0.16 2 4959.31 0.56 0.51 6-FFn 0.24 0.24 3.36 0.24 2.15 0.20 2 4959.35 0.59 0.54' 6-FFn 0.24 0.24 3.54 0.24 2.25 0.24 2 4959.38 0.62 0.59 4-FFt 0.24 0.24 3.65 0.24 2.35 0.27 2 4959.39 0.62 0.63 4-FFt 0.24 0.24 3.67 0.24 2.43 0.30 2 4959.41 0.62 0.65 4-FFt 0.24 0.24 3.66 0.24 2.51 0.33 2 4959.43 0.60 0.67 4-FFt 0.24 0.24 3.58 0.24 2.58 0.36 2 4959.44 0.59 0.68 4-FFt 0.24 0.24 3.50 0.24 2.65 0.38 El. inlet face invert 4958.76 ft El. outlet invert 4958.73 ft El. inlet throat invert 0.00 ft El. inlet crest 0.00 ft ***** SITE DATA ***** CULVERT INVERT ************** INLET STATION (FT) 0.00 INLET ELEVATION (FT) 4958.76 OUTLET STATION (FT) 5.17 OUTLET ELEVATION (FT) 4958.73 NUMBER OF BARRELS 1 SLOPE (V-FT/H-FT) 0.0058 CULVERT LENGTH ALONG SLOPE (FT) 5.17 ***** CULVERT DATA SUMMARY ************************ BARREL SHAPE BOX BARREL SPAN 2.00 FT BARREL RISE 0.24 FT BARREL MATERIAL CONCRETE BARREL MANNING'S N 0.013 INLET TYPE CONVENTIONAL INLET EDGE AND WALL BEVELED EDGE (1.5:1) INLET DEPRESSION NONE C 4= / CURRENT DATE: 04-10-1996 CURRENT TIME: 11:13:50 3 FILE DATE: 04-07-1996 FILE NAME: EVG-EXST TAILWATER ***** USER DEFINED CHANNEL CROSS-SECTION FILE NAME: EVG-EXST MAIN CHANNEL ONLY FILE DATE: 04-07-1996 LEFT CHANNEL BOUNDARY 0 RIGHT CHANNEL BOUNDARY 0 MANNING N LEFT OVER BANK 0.000 MANNING N MAIN CHANNEL 0.020 MANNING N RIGHT OVER BAN. 0.000 SLOPE OF CHANNEL (FT/FT) 0.0043 CROSS-SECTION X Y COORD: NO. (FT) (FT) 1 0.00 4963.64 2 0.00 4958.64 3 1.80 4958.47 4 3.30 4958.64 5 7.30 4959.71 6 7.30 4963.64 ******* UNIFORM FLOW RATING CURVE FOR DOWNSTREAM CHANNEL FLOW W.S.E. FROUDE DEPTH VEL. SHEAR (CFS) (FT) NUMBER (FT) (FPS) (PSF) 0.00 4958.47 0.000 -0.26 0.00 0.00 0.50 4958.80 0.643 0.07 1.72 0.06 1.00 4958.85 0.655 0.12 1.89 0.06 1.50 4958.89 0.664 0.16 2.03 0.07 2.00 4958.93 0.671 0.20 2.15 0.08 2.50 4958.97 0.677 0.24 2.25 0.08 3.00 4959.00 0.682 0.27 2.35 0.09 3.50 4959.03 0.687 0.30 2.43 0.09 4.00 4959.06 0.691 0.33 2.51 0.10 4.50 4959.09 0.694 0.36 2.58 0.10 5.00 4959.11 0.697 0.38 2.65 0.11 ROADWAY -OVERTOPPING DATA ROADWAY SURFACE PAVED EMBANKMENT TOP WIDTH (FT) 5.17 ***** USER DEFINED ROADWAY PROFILE CROSS-SECTION X Y COORD. NO. (FT) (FT) 1 0.00 4959.50 2 40.00 4959.28 3 80.00 4959.50 .�m 1 Existing 2' Metal Sidewalk Culvert @ Design Point.H7 CURRENT DATE: 05-01-1997 FILE DATE: 05-01-1997 CURRENT TIME: 12:09:30 FILE NAME: EVG-EXST FHWA CULVERT ANALYSIS HY-8, VERSION 6.0 C SITE DATA CULVERT SHAPE, MATERIAL, INLET U L INLET OUTLET CULVERT BARRELS V ELEV. ELEV. LENGTH SHAPE SPAN RISE MANNING INLET NO. (ft) (ft) (ft) MATERIAL (ft) (ft) n TYPE 1 4958.76 4958.73 5.17 1 RCB 2.00 0.24 .013 CONVENTIONAL 2 3 4 5 6 SUMMARY OF CULVERT FLOWS (cfs) FILE: EVG-EXST DATE: 05-01-1997 ELEV (ft) TOTAL 1 2 3 4 5 6 ROADWAY ITR 4958.76 0.0 0.0 0.0 •0.0 0.0 0.0 0.0 0.00 1 4959.27 1.5. 1.5 0.0 0.0 0.0 0.0 0.0- 0.00 1 4959.38 3.0 1.7 0.0 0.0 0.0 0.0 0.0 1.11 30 4959.42 4.5 1.8 0.0 0.0 0.0 0.0 0.0 2.63 17 4959.44 6.0 1.8 0.0 0.0 0.0. 0.0 0.0 4.15 14 4959.47 7.5 1.8 0.0 0.0 0.0 0.0 0.0 5.70 12 4959.49 9.0 1.7 0.0 0.0 0.0 0.0 0.0 7.25 10 4959.50 10.5 1.6 0.0 0.0 0.0 0.0 0.0 8.83 8 4959.52 12.0 1_5 0.0 0.0 0.0 0.0 0.0 10.39 6 4959.52 12.7 1.5 0.0 0.0 0.0 0.0 0.0 11.07 4 4959.54 15.0 1.5 0.0 0.0 0.0 0.0 0.0 13.36 6 4959.28 1.5 1.5 0.0 0.0 0.0 0.0 0.0 OVERTOPPING Existing 100-year design flow= 12.7 cfs SUMMARY OF ITERATIVE SOLUTION ERRORS FILE: EVG-EXST DATE: 05-01-1997 HEAD HEAD TOTAL FLOW $ FLOW ELEV (ft) ERROR (ft) FLOW (cfs) ERROR (cfs) ERROR 4958.76 0.000 0.00 0.00 0.00 4959.27 0.000 1.50 0.00 0.00 4959.38 0.000" 3.00 0.15 5.00 4959.42 0.000 4.50 0.05 1.11 4959.44 0.000 6.00 0.02 0.33 4959.47 0.000 7.50 0.02 0..27 4959.49 0.000 9.00 0.06 0.67 4959.50 0.000 10.50 0.06 0.57 4959.52 -0.001 12.00 0.09 0.75 4959.52 -0.001 12.70 0.12 0.94 4959.54 0.000 15.00 0.14 0.93 <1> TOLERANCE (ft) = 0.010 <2> TOLERANCE (o) = 1.000 2 CURRENT DATE: 05=01-1997 FILE DATE: 05-01-1997 CURRENT TIME: 12:09:30 FILE NAME: EVG-EXST PERFORMANCE CURVE FOR CULVERT 1 - 1( 2.00 (ft) BY 0.24 (ft)) RCB DIS- HEAD- INLET OUTLET ' CHARGE WATER CONTROL CONTROL FLOW NORMAL CRIT. OUTLET TW OUTLET TW FLOW ELEV. DEPTH DEPTH TYPE DEPTH DEPTH DEPTH DEPTH VEL. VEL. (cfs) (ft) . (ft) (ft) <F4> (ft) (ft) (ft) (ft) (fps) (fps) 0.00 4958.76 0.00 -0.03 0-NF 0.00 0.00 0.00 -0.26 0.00 0.00 1.50 4959.27 0.51 0.47 6-FFc 0.24 0.24 0.08 0.10 9.26 2.60 1.74 4959.37 0.61 0.56 6-FFc 0.24 0.24 0.08 0.18 10.73 3.01 1.82 4959.41 0.65 0.61 4-FFt 0.24 0.24 0.08 0.26 11.22 3.33 1.83 4959.44 0.66 0.68 4-FFt 0.24 0.24 0.24 0.32 3.82 3.57 1.78 4959.47 0.63 0.71 4-FFt 0.24 0.24 0.24 0.38. 3.70 3.78 1.69 4959.49 0.59 0.73 4-FFt 0.24 0.24 0.24 0.44 3.53 3.97 1.61 4959.51 0.55 0.75 4-FFt 0.24 0.24 0.24 0.48 3.36. 4.13 1.52 4959.52 0.52 0.76 4-FFt 0.24 0.24 0.24 0.53 3.17 4.27 1.51 4959.54 0.51 0.78 4-FFt 0.24 0.24 0.24 0.55 3.14 4.33 1.50 4959.60 0.51 0.84 4-FFt 0.24 0.24 0.24 0.62 3.13 4.52 El. inlet face invert 4958.76 ft El. outlet invert 4958.73 ft El. inlet throat invert 0.00 ft El. inlet crest 0.00 ft ***** SITE DATA ***** CULVERT INVERT ************** INLET STATION 0.00 ft INLET ELEVATION 4958.76 ft OUTLET STATION 5.17 ft OUTLET ELEVATION .4958.73 ft NUMBER OF BARRELS 1 SLOPE (V/H) 0.0058 CULVERT LENGTH ALONG SLOPE 5.17 ft ***** CULVERT DATA SUMMARY ************************ BARREL SHAPE BOX BARREL SPAN 2.00 ft BARREL RISE 0.24 ft BARREL MATERIAL CONCRETE BARREL MANNING'S n 0.013 INLET TYPE CONVENTIONAL INLET EDGE AND WALL BEVELED EDGE (1.5:1) INLET DEPRESSION NONE. V CURRENT DATE: 05-01-1997 CURRENT TIME: 12:09:30 TAILWATER ***** USER DEFINED CHANNEL CROSS-SECTION MAIN CHANNEL ONLY LEFT CHANNEL BOUNDARY 0 RIGHT CHANNEL BOUNDARY 0 MANNING n LEFT OVER BANK 0.000 MANNING n MAIN CHANNEL 0.014 MANNING n RIGHT OVER.BANK 0.000 SLOPE OF CHANNEL 0.0043 ft/ft . CROSS-SECTION X Y COORD. NO. (ft) (ft) 1 0.00 4963.64 2 0.00 4958.64 3 1.80 4958.47 4 3.30 4958.64 5 7.30 4959.71 ******* UNIFORM FLOW RATING CURVE FOR DOWNSTREAM CHANNEL FLOW W.S.E. FROUDE DEPTH VEL. SHEAR (cfs) (ft) NUMBER (ft) (f/s) (psf) 0.00 4958..47. 6.000 -0.26 0.00 0.0.0 1.50 4958.83 0.932 0.10 2.60 0.06 3.00 4956.91 0.959 0.18 3.01 0.08 4.50 4956.99 0.977 0.26 3.33 0.09 6.00 4959.05 0.990 0.32 3.57 0.10 7.50 4959.11 1.000 0.38 3.78 0.11 9.00 4959.17 1.009 0.44 3.97 0.12 10.50 4959.21 1.016 0.48 4.13 0.12 12.00 4959.26 1.022 0.53 4.27 0.13 12.70' 4959.28 1.025 0.55 4.33 0.13 15.06 4959.35 - 1.033 0.62 4.52 0.14 Note: Shear stress was calculated using R. ROADWAY OVERTOPPING DATA ROADWAY SURFACE PAVED EMBANKMENT TOP WIDTH 5.00 ft ***** USER DEFINED ROADWAY PROFILE CROSS-SECTION X Y COORD. NO. ft ft 1 0.00 4959.50 2 40.00 4959.28 3 80.00 4959.50 3 FILE DATE: 05-01-1997. FILE NAME: EVG-EXST FILE NAME: EVG-EXST FILE DATE: 04-07-1996 ---------------------- -----------------------------------=------------ C,o1 -- UDINLET: INLET HYDARULICS AND SIZING. DEVELOPED BY DR. JAMES GUO, CIVIL ENG DEPT. U OF COLORADO AT DENVER SUPPORTED BY METRO DENVER CITIES/COUNTIES AND UD&FCD ------------------------------------------------------------------------------ tU SER:Northern Engineering Services -Ft Collins Colorado ....................... .N DATE 05-07-1997 AT TIME 11:18:10 *** PROJECT TITLE: Evergreen Park *** CURB OPENING INLET HYDRAULICS AND SIZING: INLET ID NUMBER: 7 INLET HYDRAULICS: IN A SUMP. GIVEN INLET DESIGN INFORMATION: `t GIVEN CURB OPENING LENGTH (ft)= 10.00 HEIGHT OF CURB OPENING (in)= 6.00 INCLINED THROAT ANGLE (degree)= 63.43 LATERAL WIDTH OF DEPRESSION (ft)= 2.00 SUMP DEPTH (ft)= 0.08 Note: The sump depth is additional depth to flow depth. STREET GEOMETRIES: STREET LONGITUDINAL SLOPE (%) = 0.55 1 STREET CROSS SLOPE (%) = 2.00 STREET MANNING N = 0.016 GUTTER DEPRESSION (inch)= 1.12 GUTTER WIDTH (ft) = 3.67 STREET FLOW HYDRAULICS: �. WATER SPREAD ON STREET (ft) = 16.00 GUTTER FLOW DEPTH (ft) = 0.41 FLOW VELOCITY ON STREET (fps)= 2.62 FLOW CROSS SECTION AREA (sq ft)= 2.73 GRATE CLOGGING FACTOR (%)= 50.00 CURB OPENNING CLOGGING FACTOR(%)= 15.00 INLET INTERCEPTION,CAPACITY: IDEAL INTERCEPTION CAPACITY (cfs)= BY FAA HEC-12 METHOD: DESIGN FLOW FLOW INTERCEPTED CARRY-OVER FLOW BY DENVER UDFCD METHOD: DESIGN FLOW FLOW INTERCEPTED CARRY-OVER FLOW 10.93 (cfs)= 7.10 (cfs)= 7.10 (cfs)= 0.00 (cfs)= 7.10 6 GJZ (cfs)= 7.10 (cfs)= 0.00 Cil Curb Inlet / Back of Walk File Number: PRFMNC7.WQ2 Project: Evergreen Park Local Street w/ Drive -Over Curb and Gutter Street Geometry Input: W= Width from Crown to Flowline of Gutter (ft)=18 Ds= Gutter Depression (in)= 1.375 Wg= Gutter Width (in)= 14.00 Performance Curve: (Su Curb-Opening.Inlet in a Sump: (Inlet 7) When a Curb -Opening Inlet acts like an orifice (Ys+ Y)>(Hc+ Ds), its capacity is approximated by: Qi= 0.67HcLc(64.4Yo)^0.50 Where: Hc= Curb Opening Height in Feet= 6" Yo= (Ys + Y)-(Hc/2)sinO Lc= Curb Opening Length in Feet (Varies) Hc+ Ds= 6"+ 1.375"= 0.61458' Ys= Sump Depth in Feet, (Varies) Curb Opening Input: Y= Gutter Flow Depth in Feet, (Varies) Lc= 10 O= Angle of Inlet Throat= 63.43 Deg %= 15 %= Inlet Capacity Reduction Factor, (Varies) Back of Walk Overtopping: Flow over the back of walk is defined by the weir equation as: Qo= CdLH11.5 Where: Cd= Overtopping Discharge Coefficient L= Length of the Back of Walk (B.O.W.) Crest Back of Walk Overtopping Input: H= Depth of Water Overtopping @ B.O.W. Cd= 2.92 G1= Back of Walk Grade, (ft/ft) G1= 0.004 G2= Back of Walk Grade, (ft/ft) G2= 0.004 Ys+Y Yo Qi H L Qo Qt (ft) (ft) (cfs) (ft) (ft) (cfs) (cfs) 0.00000 0.0000 0.00 0.0000 0.00 0.00 0.00 . 0.52083 0.29724 12.46 0.0000 0.00 0.00 12.46 0.56250 0.33890 13.30 0.0417 20.83 0.52 13.82 0.59670 0.37310 13.96 0.0759 37.93 2.31 16.27 unma.,s, M, Ki 9$4b4� f F03, ° mgt4 l# 2 t� Q100 Inlet 7 0.68751 0.46391 15.56 0.1667 83.34 16.56 32.12 0.70000 0.47640 15.77 0.1792 89.58 19.84 35.61 0,76605 0.54245 16.83 0.2452 122.61 43.47 60.30 100-Year WSEL= 4958.76 + 0.6598 = 4959.42 Condition U) C ro n N 0 a 0 L. n C ro c U) c 0 :-J U N Existing Section C-C; Q100= 1.7 cfs Cross Section for Irregular Channel Project Description Project File c:\projects\evg\evg-swil.fm2 Worksheet Existing Swale 1 Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Section Data Wtd. Mannings Coefficient 0.035 i Channel Slope 0.001210 Wft Water Surface Elevation 4,961.52 ft Discharge 1.70 cfs Z� 4961.5 4961.8 A 4961.7 r 4961.E to N W r 4961.E 4961.4 4961.3 4961.2 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 Station (ft) FlowMaster v5.13 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Existing Section C-C; Q100=1.7 cfs Worksheet for Irregular Channel Project Description Project File c:\projects\evg\evg-swIl.fm2 Worksheet Existing Swale 1 Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.001210 ft/ft Elevation range: 4,961.25 ft to 4,962.00 ft. Station (ft) Elevation (ft) Start Station 0.00 4,962.00 0.00 29.00 4,961.25 93.00 4,962.00 Discharge 1.70 cfs Results Wtd. Mannings Coefficient 0.035 Water Surface Elevation ; --4�961.52�ft Flow Area 4.41 ft' Wetted Perimeter 33.08 ft Top Width 33.07 ft Height 0.27 ft Critical Depth 4,961.39 ft Critical Slope 0.043721 ft/ft Velocity 0.39 ft/s Velocity Head 0.23e-2 ft. Specific Energy 4,961.52 ft Froude Number 0.19 Flow is subcritical. End Station Roughness 93.00 0.035 FlowMaster v5.13 Haestad Methods, Inc. -37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 CA i it (l) j Q� I Q� i1 � o c N s A nn i +n ' N S: N a 1+ O ll J. v v r3/ Proposed Section C-C; Q2= 0.4 cfs Worksheet for Irregular Channel Project Description Project File c:lprojectslevglevgprop2.fm2 Worksheet Proposed Section C-C Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data • Channel Slope 0.002500 ft/ft Elevation range: 4,961.21 ft to 4,963.00 ft. Station (ft) Elevation (ft) Start Station End Station 0.00 4,962,00 0.00 33.00 29.00 4,961.26 33.00 35.00 33.00 4,961.29 35.00 46.50 34.00 4,961.21 35.00 4,961.29 42.50 4,962.00 46.50 4,963.00 Discharge 0.40 cfs Results Wtd. Mannings Coefficient 0.024 Water Surface Elevation 4,961.36 ft Flow Area 0.74 ft2 1 Wetted Perimeter 10.48 ft Top Width 10.47 ft Height 0.15 ft Critical Depth 4,961.31 ft Critical Slope 0.019038 ft/ft Velocity b.54 ft/s Velocity Head 0.45e-2 ft Specific Energy 4,961.36 ft Froude Number 0.36 Flow is subcritical. Roughness 0.035 0.016 0.035 11 /03/97 09:09:20 AM Haestad Methods, Inc. 37 BrooKsiae Road Wateroury, CT 06708 (203) 755-1666 FlowMaster v5.13 Page 1 of 1 Section C-C; Q2= 0.4 ds Cross Section for Irregular Channel Project Description 1 Project File c:\projects\evg\evgprop2.fm2 Worksheet Section C-C Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation 1 Section Data Wtd. Mannings Coefficient 0.024 Channel Slope 0.002500 fUft Water Surface Elevation 4,961.36 . ft Discharge 0.40 cfs C 0 m w 05/01 /97 11:20:22 AM h=5/ -s.7V 1 .L 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 Station (ft) Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 FlowMaster v5.13 Page 1 of 1 Proposed Section C-C; Q100= 1.4 cis Worksheet for Irreguiar Channel Project Description Project File 0projects\evg\evgprop2.fm2 Worksheet Proposed Section C-C Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.002500 ft/ft Elevation range: 4,961.21 ft to 4,963.00 ft. Station (ft) Elevation (ft) Start Station End Station 0.00 4,962.00 0.00 33.00 29.00 4,961.26 33.00 35.00 33.00 4,961.29 35.00 46.50 34.00 4,961.21 35.00 4,961.29 42.50 4,962.00 46.50 4,963.00 Discharge 1.40 cfs Results Wtd. Mannings Coefficient 0.026 Water Surface Elevation 4,961.45 ft Flow Area 1.92 ft2 Wetted Perimeter 15.06 ft Top Width .15.05 ft Height 0.24 ft Critical Depth 4,961.37 ft Critical Slope 0.019579 ft/ft Velocity 0.73 ft/s Velocity Head 0.01 ft Specific Energy 4,961.46 ft Froude Number 0.36 Flow is subcritical. Roughness 0.035 0.016 0.035 11/03/97 _ - 09:08:41 AM Haestad Methods, Inc. 37 Brookside Road . Waterbury, CT 06708 (203) 755-1666 FlowMaster v5.13 Page 1 of 1 Section C-C; Q100= 1.4 cfs Cross Section for Irregular Channel Project Description Project File c:\projects\evg\evgprop2.fm2 Worksheet Section C-C Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Section Data Wtd: Mannings Coefficient 0.026 ' Channel Slope 0.002500 ft/ft Water Surface Elevation 4,961.45 ft Discharge 1.40 cfs 4963.0 4962. E 4962.E 4962.4 4962.2 C 0 0 m 4962. C W 4961.6 05/01 /97 11:22:47AM 4961.6 4961.4 F7/ I Il) i- li I i I 4961.2 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 Station (ft) FlowMaster v5.13 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Prop. Pan 1; 2-Yr Design Flow= 0.8 cfs . Worksheet for Irregular Channel = = = IS Project Description Project File c:\haestad\fmw\evg-swll .fm2 Worksheet Proposed Pan 1 Flow Element Irregular Channel ' Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.002500 ft/ft Elevation range: 4,960.73 ft to 4,966.81 ft. Station (ft) Elevation (ft) Start Station 0.00 4,968.81 0.00 0.00 4,960.81 4.00 4.00 4,960.81 6.00 5.00 4,960.73 6.00 4,960.81 10.00 4,960.89 15.00 4,961.30 Discharge 0.80 cfs Results Wtd. Mannings Coefficient 0.020 Water Surface Elevation 4,960.92 ft Flow Area 1.03 ft2 Wetted Perimeter 10.49 ft Top Width 10.37 ft Height 0.19 ft Critical Depth 4,960.87 ft Critical Slope 0.011594 ft/ft Velocity 0.77 ft/s Velocity Head 0.01 ft Specific Energy 4,960.93 ft Froude Number 0.43 Flow is subcritical. . End Station 4.00 6.00 15.00 Roughness 0.035 0.013 0.035 04/10/96 10:37:21 AM FlowMaster v5.13 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Prop. Pan 1; 2-Yr Design Flow-- 0.8 cfs Cross Section for Irregular Channel Project Description Project File c:\haestad\fmw\evg-swil.fm2 Worksheet Proposed Pan 1 ' Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Section Data Wtd. Mannings Coefficient 0.020 Channel Slope 0.002500 ft/ft Water Surface Elevation 4,960.92 ft Discharge 0.80 cfs wncn r 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 Station (ft) S�GTIO,% FlowMaster v5.13 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Prop. Pan 1;100-Yr Design Flow-- 3.0 cfs Worksheet for Irregular Channel Project Description ' Project File c:lhaestad\fmwlevg-sw41.fm2 Worksheet Proposed Pan 1 Flow Element Irregular Channel ' Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.002500 ft/ft Elevation range: 4,960.73 ft to 4,968.81 ft. Station (ft) Elevation (ft) Start Station End Station Roughness 0.00 4,968.81 0.00 4.00 0.035 0.00 4,960.81 4.00 6.00 0.013 4.00 4,960.81 6.00 15.00 0.035 5.00 4,960.73 ' 6.00 4,960.81 10.00 4,960.89 15.00 4,961.30 Discharge 3.00 cfs Results Wtd. Mannings Coefficient 0.023 Water Surface Elevation 4,961.06 ft Flow Area 2.65 ft2 Wetted Perimeter 12.40 ft Top Width 12.13 ft Height 0.33 ft ' Critical Depth 4,960.96 ft Critical Slope 0.013844 fttft Velocity .1.13 ft/s ' Velocity Head 0.02 ft Specific Energy 4,961.08 ft Froude Number 0.43 Flow is subcritical. 04/ 10/96 10:36:14 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 FlowMaster v5.13 Page 1 of 1 Prop. Pan 1;100-Yr Design Flow--- 3.0 cfs Cross Section for Irregular Channel Project Description Project File c:\haestad\fmwlevg-swlt.fm2 Worksheet Proposed Pan 1 Flow Element Irregular Channel Method Manning's Formula. Solve For Water Elevation - Section Data Wtd. Mannings Coefficient 0.023 Channel Slope 0.002500 ftfft Water Surface Elevation 4,961.06 ft Discharge 3.00 cfs n 0a10f96 10:36:35AM 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 Station (ft) Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 16.0 FlowMaster v5.13 Page 1 of 1 i OL 1. m I ,=,z/ OL 1. m I ,=,z/ i! FiW Y x. !t ` qq; �i I iikl l.t. �q i Emsting Pan 2; Q2= 3.4 cfs ' Worksheet for Irregular Channel Project Description ' Project File c:lprojectslevglevg-exst.fm2 Worksheet Evergreen Park; Existing Pan 2 Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.004260 ft/ft ' Elevation range: 4,958.47 ft to 4,967.71 ft. Station (ft) Elevation (ft) Start Station 0,00 4,963,64 0.00 ' 0.00 4,958.64 3.30 1.80 4,958.47 3.30 4,958.64 7.30 4,959.71 7.30 4,967.71 Discharge 3.40 cfs Results Wtd. Mannings Coefficient 0.020 Water Surface Elevation 4,958.95 ft Flow Area 1.50 ft2 Wetted Perimeter 4.85 ft Top Width 4.48 ft . Height 0.48 ft Critical Depth 4,958.87 ft ' Critical Slope 0.008305 f tft Velocity 2.26 ftts Velocity Head 0.08 ft ' Specific Energy 4,959.03 ft Froude Number 0.69 ' Flow is subcritical. End Station 3.30 7.30 Roughness 0.013 0.035 03/11/97 02:11:46 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 FlowMaster v5.13 Page 1 of 1 E6dsting Pan 2; Q100= 12.7 cfs Worksheet for Irregular Channel Project Description Project File c:\projects\evg\evg-exst.fm2 Worksheet Evergreen Park; Existing Pan 2 Flow Element Irregular Channel }' Method Manning's Formula Solve For Water Elevation ' Input Data Channel Slope 0.004260 fttft ' Elevation range: 4,958.47 ft to 4,967.71 ft. Station (ft) Elevation (ft) - Start Station 0.00 4,963.64 0.00 ' 0.00 4,958.64 3.30 1.80 4,958.47 3.30 4,958.64 4,959.71 7.30 4,967.71 Discharge 12.70 cfs Results ' Wtd. Mannings Coefficient 0.014 Water Surface Elevation 4,959.25 ft Flow Area 2.97 ftz Wetted Perimeter 6.27 ft Top Width 5.57 ft Height 0.78 ft Critical Depth 4,959.26 ft Critical Slope 0.004006 ft/ft Velocity 4.28 fUs . Velocity Head 0.28 ft ' Specific Energy 4,959.53 ft Froude Number . 1.03 Flow is supercritical. 1 03/11 /97 02:11:32 PM End Station 3.30 7.30 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Roughness 0.013 . 0.035 FlowMaster v5.13 Page 1 of 1 Existing Pan 2; Q100= 12.7 cfs Cross Section for Irregular Channel Project Description Project File c:\projects\evg\evg-exst.fm2 Worksheet Evergreen Park; Existing Pan 2 Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Section Data Wtd. Mannings Coefficient 0.014 Channel Slope 0.004260 ft/ft Water Surface Elevation 4,959.25 ft Discharge 12.70 cfs w 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 Station (ft) 03/11 /97 02:12:15 PM FlowMaster v5.13 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 r=,/ —7 / ,-,ep / Proposed Pan 2; Q100= 10.51 cfs Worksheet for Irregular Channel Project Description Project File. c:\projectslevglevgprop2.fm2 Worksheet Evergreen Park Second Filing; Swale 2 Flow Element Irregular Channel" Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.004260 ft/ft Elevation range: 4,958.47 ft to 4,959.71 ft. Station (ft) Elevation (ft) Start Station End Station Roughness 0.00 4,958.67 0.00 6.00, 0.035 6.00 4,958.55 6.00 .9.00 0.013 7.50 4,958.47 9.00 15.00 0.035 9.00 4,958.55 15.00 4,959.71 Discharge 10 51 cfs Results Wtd. Mannings Coefficient 0.020 Water Surface Elevation 4,959.00 ft Flow Area 4.29 ftz Wetted Perimeter 11.68 ft Top Width 11.31 ft Height 0.53 ft Critical Depth 4,958.91 ft Critical Slope 0.008724 fttft Velocity 2.45 ftts Velocity Head 0.09 ft Specific Energy 4,969.09 ft Froude Number 0.70 Flow is subcritical. Water elevation exceeds lowest end station by 0.33 ft. 05/07/97 ' 11:33:24 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 FlowMaster v5.13 Page 1 of 1 Proposed Pan 2; Q100= 10.51 cfs Cross Section for Irregular Channel Project Description ' Project File c:\projects\evg\evgprop2.fm2 Worksheet Evergreen Park Second Filing; Swale 2 Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Section Data Wtd. Mannings Coefficient 0.020 ' Channel Slope 0.004260 ft/ft Water Surface Elevation 4,959.00 ft ' Discharge 10.51 cfs 4959.8 4959.E 4959.4 4959.e C O tD lL 4959.0 05/07/97 11:34:16AM 4958.8 4958.E 4958.4 L 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 Station (ft) FlowMaster v5.13 Haestad Methods, Inc. " 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 =Lo/ 00 pa 7� pz i U 4 '� rJ s a� <p IY G -o - Q LLm we ID ill Ln '7 C u o `.0 F Z G; c o 0 cc r" 0 o c o 0 U) Z = I G Z 5t u u w c cl r ,i r•� U ml �I � i •G � O 7 O L G c C o c c c c I 7 niC ID :J ' 3 G n y 0 G K • U Q I 0 L 0 '� v/ V C 0 U N U) z u� ui � I d� J 1 � J o d n ll I _ Gz� STORM SEWER SYSTEM DESIGN USING UDSEWER MODEL Developed by Dr. James Guo, Civil Eng. Dept, U. of Colorado at Denver Metro Denver Cities/Counties & UDFCD Pool Fund Study USER:NORTHERN ENG SERVICES INC-FT COLLINS COLORADO ............................ ON DATA 11-03-1997 AT TIME 10:21:38 VERSION=03-26-1994 *** PROJECT TITLE :Evergreen Park Second Filing; Storm Sewer Line 1 FILE N06 EVGSTRM2.OUT *** RETURN PERIOD OF FLOOD IS 100 YEARS RAINFALL INTENSITY TABLE IS GIVEN *** SUMMARY OF SUBBASIN RUNOFF PREDICTIONS TIME OF CONCENTRATION MANHOLE BASIN OVERLAND GUTTER ' BASIN RAIN I PEAK FLOW ID NUMBER AREA * C To (MIN; Tf (MIN) Tc (MTN) INCH/HR CFS ---------------------------------------------------------------------- 1.00 0.00 0.00 0.00 0.00 9.00 0.00 2.00 0.00 0.00 CG 0.O 9.0C 0.00 3.00 0.00 0.00 0.00 0.00 9.00 0.00 4.00 0.00 0.00 0.00 5.00 9.00 7.55 5.00 0.00 0.00 0.00 5.00 9.00 7.55 THE SHORTEST DESIGN RAINFALL DURATION IS FIVE MINUTES DENVER CRITERIA WAS NOT USED TO CHECK THE COMPUTATED Tc. *** SUMMARY OF HYDRAULICS AT MANHOLES ------------------------------------------------------------------------------- MANHOLE CNTRBTING RAINFALL RAINFALL DESIGN GROUND WATER COMMENTS ID NUMBER AREA * C DURATION INTENSITY PELkK FLOW ELEVATION ELEVATION MINUTES INCH/HR CFS FEET FEET ----------------------_--------------------------------------------------------- 1.00 0.00 0.00 O.CO 15.09 4956.00 4954.34 OK 2.00 1.68 6.06 9.00 15.09 4957.31 4955.09 OK 3.00 1.68 5.62 9.00 15.09 4958.07 4956.32 OK 4.00 0.84 5.00 9.00 7.55 4958.76 4959.42 NO 5.00 0.84 5.00 9.00 7.55 4958.76 4959.42 NO NOTE: THE STARTING WATER SURFACE ELEVATION IS CRITICAL DEPTH IN THE STORM SEWER. OK MEANS WATER ELEVATION IS LOWER THAN GROUND ELEVATION *** SUMMARY OF SEWER HYDRAULICS NOTE: THE GIVEN FLOW DEPTH-TC-SEWER SIZE R;`--C= ------------------------------------------------------------------------------- SEWER MAMHOLE NUMBER SEWER RE-UIRED SUGGESTED EXISTING ID NUMBER UPSTREAM DNSTREAM SHAPE DIA(RISE) DTA(RISE).DIA(RISE) WIDTH -------=----------------------------------------------------------------------- ID NO. ID NO. (IN) (FT) (IN) (FT) (IN) (FT) (FT) 1.00 2.00 1.00 ROUND 22.77 24..00 24.00 0.00 2.00 3.00 2.00 ROUND 22.91 24.00 24.00 0.00 3.00 4.00 3.00 ROUND 16.93 18.00 15.00 0.00 4.00 5.00 3.00 ROUND 16.93 .18.00 15.00 0.00 NOTE: SEWER ID 2.00 IS A 191'x30" HERCP. DIMENSION UNITS FOR ROUND AND ARCH SEWER ARE IN INCHES DIMENSION UNITS FOR BOX SEWER ARE IN FEET REQUIRED DIAMETER WAS DETERMINED BY SEWER HYDRAULIC CAPACITY. SUGGESTED DIAMETER WAS DETERMINED BY COMMERCIALLY AVAILABLE SIZE. FOR A NEW SEWER, FLOW WAS ANALYZED_ BY THE SUGGESTED SEWER SIZE; OTHERWISE, EXISITNG SIZE WAS USED ------------------------------------------------------------------------------- SEWER DESIGN FLOW NORMAL NORAML CRITIC CRITIC FULL FROUDE COMMENT ID FLOW Q FULL Q DEPTH VLCITY DEPTH VLCITY VLCITY NO. NUMBER CFS CFS FEET FPS. FEET FPS FPS ------------------------------------------------------------------------------- 1.0 15.1 17.4 1.44 6.24 1.42 6.34 4.80 0.95 V-OK 2.0 15.1 17.1 1.46 6.15 1.42 6.34 4.80 0.92 V-OK 3.0 7.5 5.5 1.25 6.15 1.08 '6.69 6.15 0.00 V-OK 4.0 7.5 5.5 1.25 6.15 1.08 .6.69 6.15 O.00 V-OK ' FROUDE NUMBER=O INDICATES THAT A PRESSURED FLOW OCCURS SEWER SLOPE INVERT ELEVATION BURIED DEPTH COMMENTS - ID NUMBER 'UPSTREAM DNSTREAM UPSTREAM DNSTREAM % (FT) (FT) (FT) (FT) ---------------------------------------------------------------------- 1.00 0.59 4953.66 4952.92 1.65 1.08 OK 2.00 0.57 4954.77 4953.86 1.30 1.45 OK 3.00 0.61 4956.95 4955.55 1.00 1.27 OK 4.00 0.61 4956.95 4.955.55 1.00 1.27 OK OK MEANS BURIED DEPTH IS GREATER THAN REQUIRED SOIL COVER OF 1 FEET *** SUMMARY OF HYDRAULIC GRADIENT LINE ALONG SEWERS ------------------------------------------------------------------------------ SEWER SEWER SURCHARGED CROWN ELEVATION WATER ELEVATION FLOW ID NUMBER LENGTH LENGTH UPSTREAM DNSTREAM UPSTREAM DNSTREAM CONDITION FEET FEET, FEET FEET FEET FEET. -----------------------------------------------------------------=------------ 1.00 124.64 0.00 4955.66 49S4.92 4955.09 4954.34 SUBCR 2.00 160.11 0.00 4956.77. 4955.86 4956.32 4955.09 SUBCR 3.00 230.39 230.39 4958.20 4956.79 4959.42 1 4956.32 PRSS'ED 4.00 230.39 230.39 4958.20 4956.79 4959.42 4956.32 PRSS'ED PRSS'ED=PRESSURED FLOW; JUMP=POSSIBLE HYDRAULIC JUMP; SUBCR=S'JBCRITICAL FLOW *** SUMMARY OF ENERGY GRADIENT LINE ?LONG SEWERS ---------------------------- UPST MANHOLE --------------------------------------------------- SEWER .JUNCTURE LOSSES DOWNST MANHOLE SEWER MANHOLE ENERGY FRCTION BEND BEND LATERAL LATERAL MANHOLE ENERGY ID NO ID NO. ELEV FT FT K COEF LOSS FT K COEF LOSS FT ID FT ------------------------ 1.0 2.00 7------------------------------------------------------- 4955.70 1.36 0.08 0.00 0.00 0.00 1.00'4.954.34 2.0 3.00 4956.91 1.11 0.28 0.10 0.00 0.00 2.00 4955.70 -3.0 4.00 4960.04 2.72 0:70. 0.41 0.00 0.00 3.00 4956.91 4.0 5.00 4960.04 2.72 0.70 0.41 0.00 0.00 3.00 4956.91 BEND LOSS =BEND K* FLOWING FULL VHEAD IN SEWER. LATERAL LOSS= OUTFLOW FULL VHEAD-JCT LOSS K*INFLOW FULL VHEAD FRICTION LOSS=O MEANS IT IS NEGLIGIBLE OR POSSIBLE ERROR DUE TO JUMP. 4 41 FRICTION LOSS INCLUDES SEWER INVERT DROP AT MANHOLE NOTICE: VHEAD DENOTES THE VELOCITY HEAD OF FULL FLOW CONDITION. A MINIMUM JUCTION LOSS OF 0.05 FT WOULD BE _INTRODUCED UNLESS LATERAL K=O. FRICTION LOSS WAS ESTIMATED BY BACKWATER CURVE COMPUTATIONS. *** SUMMARY OF EARTH EXCAVATION VOLUME FOR COST ESTIMATE. THE TRENCH SIDE SLOPE = 1 ---------------=--------------------------------------------------------------- MANHOLE GROUND INVERT MANHOLE ID NUMBER ELEVATION ELEVATION HEIGHT FT FT FT ------------------------------------------------------------------------------- 1.00 4956.00 4952.92 3.08 2:00 4957.31 4953.66 3.65 3.00 4958.07 4954.77 3.30 4.00 4958.76 4956.95 1.81 5.00 4958.76 4956.95 1.81 ------------------------------------------------------------------------------- SEWER UPST TRENCH WIDTH DNST TRENCH WIDTH TRENCH WALL EARTH ID NUMBER ON GROUND AT INVERT ON GROUND AT INVERT LENGTH THICKNESS VOLUME FT FT FT FT FT INCHES CUBIC YD - ------------------------------------------------=------------------------------ 1.00 6.80 4.50 5.65 4.50 124.64 3.00 94.4 2.00 6.10 4.50c.=1 4.5C 160.11 3.00 121.4 3.00 3.99 3.63 :.:2 3.63 230.39 2.25 101.E 4.00 3.99 3.63 5.42 3.63 23G.39 2.25 101.6 TOTAL EARTH VOLUME FOR SEWER TRENCHES = 418.946 CUBIC YARDS EARTH VOLUME WAS ESTIMATED TO HAVE BOTTOM WIDTH=DIAMETER OR WIDTH OF SEWER + 2 - B B=ONE FEET WHEN DIAMETER OR WIDTH <=48 INCHES B=TWO FEET WHEN DIAMETER OR WIDTH >48 INCHES IF BOTTOM WIDTH <MINIMUM WIDTH, 2 FT, THE MINIMUM WIDTH WAS USED. BACKFILL DEPTH UNDER SEWER WAS ASSUMED TO BE ONE FOOT SEWER WALL THICKNESS=EQIVLNT DIAMATER IN INCH/12 +1 IN INCHES Q � l7.a�1Gr=S 5-7 vifc 'roc L m GLl AW U Ron OC 0 Jy� O\qF N �c. M TYPE L Use Do instead of 0 whenever flow is supercritical in the barrel. **Use Type L for a distance of 3D downstream . FIGURE 5-7. RIPRAP EROSION PROTECTION AT CIRCULAR CONDUIT OUTLET. ' FIGURE 5-7 IS VALID FOR 0/ D2.5-, OF 6.0 OR LESS. W J m H 0= DESIGN DISCHARGE M CFS D= CIRCULAR CONDUIT DIAMETER IN FEET 4 Yt = TAILWATER DEPTH 0 00 0 U N In W LL O O` a � O � V v d d L � � N v �CIO N J v c L u v`i o � U 0 W CD 0 0' 7 m Ml W o' RAINFALL PERFORMANCE STANDARD EVALUATION PROJECT: Evergreen Park Second Filing STANDARD FORM A COMPLETED BY: Mary B. Wohnrade, P.E. DATE: May 7, 1996 Developed Erodibility Asb Lab Ssb Lb Sb PS(rable 8-A) Sub -Basin Zone (ac) (ft) (%) (ft) 1 Moderate 1.541 340 1.70 2 Moderate 1.443 696 0.95 3 Moderate 0.859 325 1.70 Total = 3.843 470 1.42 79.3 4 Moderate 1.103 562 0.75 75.3 5 Moderate 1.531 546 1.17 78.4 8 Moderate 0.606 160 1.00 75.6 9 Moderate 0.312 160 2.13 79.1 Total = •7.395 3.843(79.3)+1.103(75.3)+1.531(78.4)+0.606(75.6)+0.312(79.1)/7.395=- 78.2 Lb = sum (Lsb x Asb) / sum Asb Sb = sum (Ssb x Asb) j sum Asb Performance Standard (PS) = See Table 5.1 EFFECTIVENESS CALCULATIONS PROJECT: Evergreen Park Second Filing STANDARD FORM B COMPLETED BY: Mary B. Wohnrade, P.E. DATE: May 7, 1996 Erosion Control Method C-Factor P-Factor Comment Hay Mulch 0.06 1.00 Basins' 1-3,5 Bare Ground 1.00 0.90 Basins' 4,8,9 Roads/Walks 0.01 1.00 Basins' 1,3A8,9, Gravel Filter 1.00 0.80 Basins' 1 - 4 Silt Fence Barrier 1.00 0.50 Basins' 4,5,8,9 Straw Bale Barrier 1.00 0.80 n/a Major Performance Sub -Basin Area Calculations Basin Standard (%) (Ac) 1,2,3 79.3 3.843 Roads/Walks = 0.554 ac Hay Mulch = 3.289 ac Gravel Filter Net C Factor = 0.554(0.01)+3.289(0.06)/3.843 = 0.053 Net P Factor = 0.80 EFF = (1-(0.053 x 0.80))/100= 95.8% 4 75.3 1.103 Roads/Walks = 0.305 acres Bare Ground = 0.798 acres Gravel Filter, Silt Fence Net C Factor = (0.305(0.01)+0.798(1.00))/1.103 = 0.73 Net P Factor = 0.804.804.90=0.58 EFF = (1-(0.73 x 0.58))/100= 57.7% 5 78.4 1.531 Silt Fence Hay Mulch = 1.531 Net C Factor = 0.06(1.531)/1.531 = 0.06 Net P Factor = 0.50 EFF = (1-(0.06 x 0.50))/100= 97.0% 8 75.6 0.606 Streets/Walks = 0.465 Bare Ground = 0.141 ac Silt Fence Net C Factor = (0.01(0.465)+1.00(0.141))/0.606 = 0.24 Net P Factor = 0.504.90=0.45 EFF = (1-(0.24 x 0.45))/100= 89.2% 9 79.1 0.312 Streets/Walks = 0.141 ac Bare Ground = 0.171 ac Silt Fence Net C Factor = (0.01(0.141)+1.00(0.171))/0.312 = 0.55 Net P Factor = 0.50xO.90= 0.45 EFF = (1-(0.55 x 0.45))/100= 75.1% 3.843(95.8)+1.103(57.7)+1.531(97.0)+0.606(89.2)+0.312(75.1)/7.395 = 89.0 > 78.2 :. OK o mm000 o ��tntn� to WWWWW o m m m m o 0 0 0 0 0 O Iwo.4 nL�tnuttntc .r WcoWWWWWWWW o commc,mrnmmmmmmo00 o v-WO v.r-w•ry"to v aow-win* tntoo M ODWOD00CID 00WWODWODWWWW o r W W W m m m at m m m m m m m m m m m m N W W W W CO W CO OD W CO OD W W W W OD W W W W 0 o�1�r•n�o�oto�orrrrrrrrr"rrrW W W W W W W qw •0-1 00OODWODmOODDOODDOODDCDDOODDWWWOWDWODWOWoOWDWOWoOWoOWDOWomOWD O wmmvnthmw,oww wwtoo nnnrtoo rnrnWWW m Mqw-W-WVIVIVaTlwqwsrsravvaow-WvaqwerawawIV1w UODOD OD WWW WWW00WODCDODODOo000DODWWW OD CO W W o%0oNeowgrtntninmw%owtototow%owvnrnrrr . . . . . . . . . . . . . . . . . . . rn W McPd'd'eYd'd'd'd'd'ef"d'd'd'ef' V' V'd'd'd'el'd' V'ePd'd' N W W W W W W W W W W W W W W W W W W W "W W W W W W W �] O d'm.iNMM�af qw w n u, un w) tn Ln w) tn tn %o %o %o %o %0 wrO O n t"+mgw-'a-W-Werer�ad U 00 00 W OD W W W W W W W W W W W W W W W W W W W W W W 'a O O10W OrlrINNMMMMap V' V'eN�ertl'�'W W Wtn�p�0 . . • • . • . • • • . . . • • • • . • • • . • • • O 10 N1MMd'at44 V' V'd'd's1'd'sPd' V'eFePd'ePd'd'eP444 W W W W W W W W W W W W W W W W W W W W W W W W W W W 10 dp .�O •nNlnn W mOOrIrIrINNNNNMMMMM���a}� W G4. vtn 04m en m mr)-0 qw lw-0V V' d' al'd'V'eP w y W W W W W W W W W W W W W W W W W W W W W W W W W W W ►.7 atn.-IW�tM�rtn,tn�o�onnrWWoocoaoWo�rno�00000 as Q. .......................... N N M MM M en M M M M M MM M M M M M M M 10-W E y ODWWODWWWWWWWWWOOOOWWWWWWWWWWW E o %0tnW0.4cmengw �tntnin�o�D� wwg� rrrWWWrnm . • . . . . . . . . . . . . . . . . . . . . . . . . . � ep r4 N N M M M M M M M M M MMMMM M M M M c4 M MMM W W W W W W W OD W 00 00 W W W W W W OD W W W W W W W W W U In r4r-ILnnW001-INNCfMengrgWqW W Wtntn1A101C10rn" M 4 N N N N M M c4 N1 M M P9 M M M MM M r•1co; MM M M MM W WWW WWWWWW W W W W W W OD OD OD OD W OO W W W W 0 O MN�O WmO.-INNMMf+fer����� W W W W W W W 04 M Ori�"Irl4C44NN44NN444444N4N444N4 aw Oo 0o W co 00 00 0o Do W OD 00 0o ao 00 00 0o W 00 00 0o WWWWW W a to In•nmNM�•ntornn0o0ooDmmmmmm000000 N 000rl•-Irlrlrl.�•-leirlrl•„I•�1•�I4NN44N w n 00 00 00 00 0o W 0D 00 00 00 0D 0D 00 oD 0o W oD 0o ao 0o W W W W W 'Z. O V'•nOM•n1p W Opm000r1r1•-IrINNNNMMf+1Mf+1M N W mOOOOOOOrt�rlrirlrl.�,�rlr+rtrf..{��.{�� r r Oo W 0o W 00 0o aD W 00 0D 00 oD W 00 0o co 00 00 0o W W W W W In W N W.-I�InnnW mm00.-i.i.-I..4rINNNMMMMM W OOmmmmmmmm000000000000000 rnnnrnrnrnrwwwwWWODODW W W W W W W o �oMo�rmo.iNMM��tntnultn�o�o�o�onr�o�o�o . . . . . . . . . . . . . . . . . . . . . . . . . . . •-I .f'�onnrroocooDODco W W W W W W OD OD co op W W W W W nnnnnnrrnnrrnrrrrrnrrrrnrr to 0%0V%0rWWr9-r%0%0WLngWVMMNN0%%0 W Im o . . . . . . . . . . . . . . . . . . . . . . . . . . . O O N N N N N N N N N N N N N N N N N N N rt 4 rl rf O O rrnrrnrrrrrrnrrrrrrrnrrrnn x 3E-. o0000000000000000000000000 Z E 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 aWv.-+NMatn�orWmo.iNMvtn�onWmotnotrlotno V4 rt r, rt r1 rt N N M M v d to h 3/ MARCH 1991 8-4 DESIGN CRITERIA O 04 az WO Paz C7 O woo WW R F. a O O O O O C 0 0 0 0 0 0 0 0 O O 00 00 O O O h 601) 609, 0 0 0 0 0 o II II _ o00000 .�.a a O � H U z� o �o cm o awoo W 141 {r/ F F 0 .o N p W O N n O O O se QUW.w.7W W k � z� o� N O rn ¢ O wa Q"w F 7a p U F FW- wOR, v� rs. v C w w rA W; vi w w �O UU> ; FO FOG •• cnO O F¢FrF„ U O oQ o00 3 a w U 00 �°^ww33 xa �0C7U)C'n T f Department of Energy `f Western Area Power Administration , Rocky Mountain Customer Service Region P.O. Box 3700 Loveland, CO 80539-3003 ' AUG 2 6 1997 Ms. Mary B. Wohnrade P.E. ' Project Engineer Northern Engineering Services, Inc. 420 South Howes, Suite 202 ' Fort Collins, CO 80521 Dear Ms. Wohnrade: I' Enclosed is a license agreement for the 50-foot drainage easement that R.J. Develco, Inc., proposes to construct on the Western Area Power Administration easement for the Poudre- , Richard's Lake Transmission Line in Section 1, T.7N., R.69W., 6th P.M., Larimer County, , Colorado. .. If the license is satisfactory, please have it executed on behalf of R.J. Develco, Inc., and return M it to this office for execution on behalf of the United States. If you have any questions on this matter, call me at (970) 490-7284. Sincerely, Dave Gaul Realty Officer Enclosure UNITED STATES OF AMERICA DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION Poudre-Richard's Lake 115-kV Transmission Line Section 1, Township 7 North, Range 69 West 6th Principal Meridian, Larimer County, Colorado Vicinty of Structures 20/8 and 20/9 LICENSE AGREEMENT THIS LICENSE AGREEMENT, made this day of , 1997, between R.J. DEVELCO, INC.(LICENSEE), whether one or more, and the UNITED STATES OF AMERICA, Department of Energy, Western Area Power Administration, (Western), represented by the officer executing this agreement, pursuant to the Reclamation Act, Act of June 17, 1902, 32 Stat. 388, and acts amendatory thereof.and supplementary thereto, and the Department of Energy Organization Act, Act of August 4, 1977, 91 Stat. 565. WITNESSETH: Western concurs that the 50-foot drainage easement (FACILITY) proposed by the LICENSEE will not interfere with the operation and maintenance of Western's Poudre- Richard's Lake 115-kV Transmission Line, if constructed in the manner and at the locations shown on Exhibit A, attached hereto and made a part hereof. In consideration of Western's concurrence, the LICENSEE agrees to the following: (a) This license does not grant any right, privilege, or interest in the land The LICENSEE is responsible for obtaining any necessary land rights from the underlying landowner. (b) This license is only valid provided the FACILITY is constructed, operated and maintained in conformance with the attached drawings and/or exhibits. Any relocations, changes, or upgrades require additional concurrence by Western. LICENSEE agrees to alter or relocate its FACILITY, at no cost to Western, to accommodate future modifications of Western's facilities, including but not limited to, upgrades of the transmission line. (c) LICENSEE shall notify Western at least 10 days prior to commencing installation of the FACILITY to permit inspection by WESTERN; Contact Bud Jones in our Loveland office, (970) 490-7314. (d) To abide by and comply with all applicable Federal, State and local laws and building and safety codes. (e) LICENSEE agrees to indemnify and hold harmless Western, its employees, or agents, from any loss or damage and from any liability on account of personal injury, death, or property damage arising out of Licensee's, its agents, contractors, or subcontractors use of the land covered by this License Agreement. (f) This agreement shall be binding on the successors or assigns of LICENSEE and Western; however, it shall not be assigned by LICENSEE without prior written consent of Western. (g) A minimum clearance of at least 12 feet from the conductors must be maintained at all times. LICENSEE R.J. DEVELCO, INC. - 605 SOUTH COLLEGE AVENUE FORT COLLINS, CO 80524 (Signature) (Title) THE UNITED STATES OF AMERICA Western Area Power Administration Acting Regional Manager t ..run—�O—w r r "V 1 1 : 10 LVYCLMrvL• MKGM �•r... rrr•_. ,.. -r n� EXHIBIT A ' Western Area Power Administration Page 1 of 2 Rocky Mountain Customer Service Region NOTE: A minimum clearance of RIGHT-OF-WAY USE APPLICATION least 12 feet from the conductors must be maim Date: /'er,5-1 tained at all times. Transmission Line: ! p^���— ��YGJNc l!� K-✓ �z�rfy�aSt'io.J L r�� , Description of Proposal (Narrative): !r`!c-L-'^oe-� R _•fit-'+� Jss�ic E.�sc v,� d i7GSi 6. ..l q—f).�r� �R- i>< `Jc7' loot-iro,J o/= %I'i-C EXS Ti•.l �i %' NS3rZ Ca[c..�lC/�I j , Location: Section 1 Township -7 4 Rangc L5 vv G —r I (Meridian) ' County: State: Complete if applicable: SubdivisionEw'85f--,x-e='4 r=•.-.-44 , Lots ) —9 , Block I City PROFILE: Show the location, height (feet), and distance (feet) from the nearest transmission line structure. WAPA Structure `~�-�� WAPA Structure G c. ound Surf:�ce PLAN: Show the location and dimensions (in feet) of the proposed facility in relation to the center conductor of the transmissiion line. Transmission Line WAPA Structure_ No. 20/8 ROW-------------------- ----------------------------- --------------- ROW I Transmission Line WAPA Structure— *- --------- No. 20/9 -----------------------------------------------ROW Show NORTH by arrow at (+) in block ------- ------- at left and show approximate location in Section at right. Attach other drawings and information as appropriate. NW I/4 %WI/4 'SCl/4 Address: Telephone No.: (91d )3• ' SUOARM E s � � O r O O14 - b / / r / / r / I A;AcIl, . / u YEW COURT .-- �, / f a /• 70 n'�0�� J /i � j q'i R� -'�'-,> t, A owl ��pgg�• m (%�O �l'� � /I � g n �z;qa 4 :a /• p 9 0 $ N S g6 O O R��R Z A -f S ----- _ � � r0 /•• �•• A Z N y � S • is ,Q m In / y O q (71 j $S N / � ZA� i e co (D 0 0 C. 0 P+ N 01 0 Ml l< (D v (D co August 29, 1997 Northern Engineering 420 South Howes Street Suite 220 Fort Collins, Colorado 80521 Attn: _ Mr. Mike Jones Re: Drywell Design Evergreen Park Fort Collins, Colorado EEC Project No. 1972062 Mr. Jones: -00 Ali 1 EEC 6:2 1 EARTH ENGINEERING 1 CONSULTANTS, INC. 1 As you requested, a senior project engineer from Earth Engineering Consultants, Inc. (EEC) has completed a design for the proposed drywell at the Evergreen Park area in Fort Collins. A diagram for that design is included with this report; that information is also being provided with this letter in AutoCAD 13 format on the enclosed disk. The drywell design is based on a peak discharge of 3.2 cubic feet per second with minor surface ponding of the discharge water. The surface area of 788 square feet could be developed with essentially any configuration. It will be crucial for the operation of this drywell that the ground surface in this area be maintained to prevent clogging of the surface of the drywell. In our test borings at this site, no free groundwater was observed. With the granular site materials and apparent depth to groundwater, we do not expect the drywell will cause -an unacceptable rise in adjacent groundwater levels. If you have any questions concerning the enclosed information, or if we can be of further service to you in any other way, please do not hesitate to contact us. Very truly yours, Earth ig Consultants, Inc. 1 .0�0�►Q• �� �Sr�n; T v ®: 957 Lestets.S'l�n 1 PrincipaY'Yigiti' er LLL/dmf 1 CENTRE FOR ADVANCED TECHNOLOGY 2301 RESEARCH BOULEVARD, SUITE 104 - • FORT COLLINS, COLORADO 80526 - 1 (970) 224-1522 (FAX) 224-4564 .JZ� Cf. !-' A 11 Area = 788 sf . Excavate Silty Sandy Cloy and Replace w/ free draining grovel (3/4' Weathered Rock or Excavated Site Grovel) Approx. 3.5' to 4' Natural Silty Sandy Cloy (CL) p 0 0p 0 0 0 0 0 0 0 0 � 0 00 0 C 0 0000 000 00000 p p 000 0 0 0 000 00 O p 0 0000 p p 00 O 0 00 O 00 O pO p 00 0 p 0 p 00 000 00 0 O O 0 00 O p 0 000 0 00p 000 OO 00p OO 00 Natural Gravel w/ Sand (SP/GP) Cobbles w/ depth Section A 11 Sheet 1 EVERGREEN PARK DRYWELL FORT COLLINS, COL❑RAD❑ PROJECT N0:1972062 DATE: AUGUST 1997 EARTH ENGINEERING CONSULTANTS EVERGREEN PARK _I 3 FORT COLONS, COLORADO PROJECT NO: 1872062 DATE: JULY 1997 LOG OF BORING B"1 RIG TYPE: CME45 SHEET 1 OF 1 WATER DEPTH FOREMAN: OSH START DATE 07115197 WHILE DRILLING None AUGER TYPE: 4" CFA FINISH DATE 07/15197 AFTER DRILLING None SPT HAMMER: MANUAL SURFACE ELEV WA 24 HOUR WA SOIL DESCRIPTION D N Ou MC 0D A -LIMITS -200 SWELL LL PI PRESSURE %@ SOd PSF TYPE (FEET) (BLOWS/FT) (PSF) (%) (PCF) (%) SANDY SILTY CLAY (CL) 1 olive/brown medium dense 2 SS _ 8 3000 7.9 30 14 74.2 3 4 GRAVEL W/ SAND (GP/SP) SS _ _ 50/10" 6.3 brown 5 medium dense w/ apparent Cobbles 6 7 4.1 8 9 10 11 12 13 GRAVELLY SAND(SP/GP) brown 14 medium dense SS _ 50l9" 11.4 I 15 16 BOTTOM OF BORING 15.5- _ 17 18 19 20 21 22 23 24 25 Earth Engineering Consultants / \ RUNOFF TABLE / / \ \ kT GEwi�� r r.. . Imp ARENA A LAN, E SEA OJErm ASSETS RAISING 2. TRACER A -SEEN - WE PLO l2 r�A d r�ll� i� r — •?.�� \ NORTH r di l�s\��'�. d,.T �i*F, s � � _ ,' - - \-\ GRAPHIC SCALE `•. ••� `0 WE LOSE FINE ft RAW, WELL FOR US G 5 )ELM NUM FARM SET ALL arrf� I ' I � E. �I ( 1 1._AN�s b y g •s gp / , r W.• ' F/. __ STRONG STORM SAINT a AM'S V 4 n>R I / - I I •• '_` wI ae�ro srouu scwsv I I 1 I ru • �� l �� STORMPRINT Ar,� —>o— 4w.aEo cO+Erw�e rc .way ss w rcscx DRAINAGEeww+ ! 11 IN I A (((j 2 Y ll�� AREA IN MCI o-�z1I„e FENCE e +� `% art I A [[suvsrt / ��• mr I 1 2 d I % w N, ' - EnOT nue nILING wnosEus[ e a >a ❑ } I d, FUTIiIE CULVERT "' IT I y� I .,w,. zE�w . ARTS,, .,,, _ z� >EC,o. I ' 6 e ' , zr�w FEETsmrt-ossa m• r � .won o i Ewen... [IISi. ri IEO' ROW. .o / CITY OF FORT COLLRIS, COLORA00 E m. w+Eortx cw ,. � vrscxv ux cuKxE ' v In w x ) � � UTILITY PLAN APPROVAL (L'ETAL 96DEXALK CUSTOMER - see ry a mOi vw - - - - - --CA Ilr _J EFp PR ESTASTETR - _ 1 2 3 4 5 1 6 J 6 9 +Es a¢o u ar ....uu.Ace.Em y( Rl a s ixwe usEue E ttWA am R 4 sc - mrc rsresz u EoTz s ro +4 _ _____ ____ __ lro.mr.c swuua rwawm ___ _- OPERTY011lICR 1 0 w S - --- --- w - __ 5 -a3E.. m..J� __ ----- �SLUN Czx owT ue .e�" fie.¢€. — 7 APPRO ' 6 R6E4� aol[siu - E 5 R - r - w __ �.�mrsis.. e _ e c E L :( _ �L ..xo+w. .+Tad BLOCK 7 •1-,2 ;,,m„a., e4,i� -- -----. -- --- ------ --------=--- ----- - -- ---- ---- x ---------- - — — ------ --- ---- ------ n --- Si -- 11 -- - ---.�--,- wo _ RNA, - — :�E_o.,R eat: ...:, vOE.w,.. E.w . wR. r.. EVRa s u.'nw • a ANxrsx[o C w F e CONFER - e -- STREET (sa oo.E wlrE. .! MAMLOGRANT 7) Di. (se ROW.) • •• e• •. 6 S .. - I• P _ `-I .' I e... AIR USE , .ue �. IGN No PAU — NEAR OULF (SE'REFLECTIONES1) EAST DETENTION POND 100-YR SECT- 4955,10 Project: Print Date: EVERGREEN PARK SECOND FILING Es� �2THERN ENGINEERING SERVICP;S 9611.00 �cA :)'=45' FINALazo Bollix xo1115-smTe zoz. Fr COULGII COD)RA00 90sz1 DEs ER :Maw cxECREo 9v:RAc IDRAINAGE PLAN(990) 221-4156 DRAEi51AAN:ACADRI4 PREPARE0:06 21 98 !