Loading...
HomeMy WebLinkAboutDrainage Reports - 05/05/20061 1 City of Ft. Cd er! Plana Kter-Mountain pate �► �� n� pr Lt& ■ PROPERTY OF FINAL DRAINAGE STUDY FOR PORT COLUNS PANDA EXPRESS 4600 SOUTH MASON STREET CITY OF FORT COLLINS, COLORADO 1 ' N PREPARED FOR: ' CONCEPTS WEST ARCHITECTURE, INC. SUITE 100 831 SOUTH NEVADA AVENUE COLORADO SPRINGS, COLORADO 80903 i t " PROJECT NO. 06-9006 PREPARED BY: 1 INTER -MOUNTAIN ENGINEERING KAREN.KIDD, EI. 1 ANDREW CORNELIUS, P.E. APRIL 2006 8392 Continental Divide Road, Suite #107 • Littleton, Colorado 80127 • Phone: 303 948 6220 • Fax: 303 948 6526 ' 40801 U.S. Hwy. 6, Suite 203 • P.O. Box 978 • Avon, Colorado 81620 • Phone: 970 949 5072 • Toll Free: 800 856 2258 i 1 1 1 1 1 1 1 ENGINEER'S. CERTIFICATION I hereby certify that this Final Drainage Study for Panda Express at 4600 Mason Street was prepared by me (or under my direct supervision) in accordance with the provisions of the City of Fort Collins Storm Drainage Design Criteria and Construction Standards for the owners thereof. Andrew Cornelius, Register% Surveyor , Colorado Professional Engineer and Registered Professional Land GENERAL LOCATION AND DESCRIPTION This Final Drainage Study has been completed for Concepts West Architecture in order to present an effective stormwater management plan for the re -development of the site at 4600 Mason Street as a Panda Express. This study confirms the re -developed design of the site meets the master drainage design criteria established within the original development of the Amigos Restaurant at Arbor Plaza by RBD Engineering Consultants in May 1993. The proposed Panda Express site was originally developed as an Amigos Restaurant at Arbor Plaza. The site is bounded to the north by Harmony Road, to the west by Mason Street, to the south by an access road and'to the south and east by "Ultimate Electronics." The site consists of 0.93 acres and is proposed to be re -developed as a Panda Express Restaurant with a drive-thru. The proposed re -development of the site includes resurfacing, adjustment to curb and gutter, replacement of utility service lines, replacement of concrete surfacing adjacent to the building, incorporation of a swale and sidewalk chase/concrete pan combination, and relocation of the trash enclosure. DESCRIPTION OF PROPERTY The existing site is mainly hardscape with either asphalt and concrete pavement or concrete sidewalks, with landscaped areas around the perimeter of the parking lot and directly adjacent to the building. The existing terrain is fairly mild, mainly draining to the east with a small portion draining to the south. There is an existing Type R curb inlet on the eastern portion of the site that collects the majority of the drainage; the remainder drains south to the Access Drive. IDRAINAGE BASINS AND SUB -BASINS ' The Grading, Drainage, Erosion Control, and Utility Plan by RBD Engineering Consultants for the Amigos at Arbor Plaza PUD defined the drainage:basins and design ' points for the site. RBD Engineering Consultants identified the site as two major basins labeled Basin I and Basin 2. Each basin has an associated design point or flow summary point. The proposed re -development is contained within Basin 1, but maintains the same basin boundary and the associated design point. The proposed re -developed includes the establishment of Sub -Basin I to direct stormwater away from the proposed building by incorporating a drainage swale and sidewalk chase/concrete pan combination. Basin 2 is not affected by the re -development. The existing two major basins and the proposed sub - basin are shown on the Drainage Basin Plan in the Appendix, Exhibit 1. DRAINAGE DESIGN ' This study was prepared in accordance with the City of Fort Collins Storm Drainage Design Criteria and Construction Standards. The Rational Method was used by RBD Engineering Consultants to develop peak discharges corresponding to the 10-Year and 100-Year events for the original Amigos _ development. The proposed re -development is contained within Basin I and maintains the same basin boundary, design point, time of concentration and resulting intensity. Thus, this study will simply compare the runoff coefficients of the original development and the proposed re -development to ensure the original drainage structures are adequate. The runoff coefficients were derived from the City of Fort Collins Storm Drainage Design Criteria and Construction Standards Table 3-3. Basin I CIO Basin 1 Cioo Original development 0.83 1.00 Proposed re -development as 0.80 1.00 a Panda Express 1 The runoff coefficients calculated in this study for Basin 1 are less or equal to those determined by RBD Engineering Consultants for the original development. Thus, the ' resulting discharge from the 10-Year and 100-Year events will be less than or equal to that compiled by RBD Engineering Consultants for the original development. The Rational Method was also used to assess the proposed sub -basin, Basin 1-A. The stormwater flows within the basin resulting from the 10-Year and 100-Year storm events were determined and the depth of water within the swale and concrete pan were assessed. The detailed drainage calculations and flow computations can be found in the Appendix. DRAINAGE FACILITY DESIGN The Grading, Drainage, Erosion Control and Utility Plan by RBD Engineering , Consultants contains the initial storm and accommodates the major storm so there will be no impact to the development lots. The proposed swale and sidewalk chase/concrete pan combination contain the initial and major storm. ' WATER QUALITY The water quality will be addressed with inlet protection and concrete washout basin as Ishown on the Erosion and Sediment Control Plan in the Appendix, Exhibit 2. 1 1 1 1 1 1 1 1 1 1 1 A 1 1 REFERENCES 1. City of Fort Collins, Colorado; Storm Drainage Design and Technical Criteria; April 1997. 2. Grading, Drainage Erosion Control and Utility Plan; RBD Engineering Consultants; May 1993. 3. Urban Drainage and Flood Control District, Urban Storm Drainage Criteria Manual Volume 1, June 2001 (latest revision March 2005). No Text C � m Y U U N m LL O C U � o E > > � a Q • O .O U 7 O U � Q N o in J t� 0 0 U) N r C N x d � Q d o73 U40 0 a m '0 m CL 0 O _N R IL 0 O A' N . a ia G� N m (n N) K L W .' Q C a U •� ro O m C O •N �c �m � o m F m N O N O N L U O O U _- N 00 C o :° N cli c o + F N m m co r� T - a r O O m co n C O. A U O O C C C f0 N U) m c o _m u U r m N N G N O co co U c F N U F- 0 m m � n (p vi c rn N d C ` 6 O N �j o E c 0 m v U 55 N G N OD CO mr' N w -. N N oo O v. a¢ Zc C U C LLo O 0 0 E % C `o 3 U) OTF C Y .N c Y p U) N LL U t C 0) 0) Q 0) 0) O w LL w N 0 c o c o F C LL m O C U c) 01 c C E Q Q Q Q o ii N a 10 'C m.5 C R . a T3 7 m N �. L Q IL N_ m Co a.m O c c c O N U C E o E N U N o CO U C2 O co C coi c i C C � O O O O �♦ i 0 W _E 3 0 LL 0 c O C U! ' V � c U o .0 � _f i r m rn rn C,4 C m c U Z m � m � n c m � � 3 � C O > N C CNN 0 CA N N CC N NON O Clq OOW I-N ON J O }0 wO OO O .vW W 0 > y o 0 0 N� 3 N NN� C9O N O O O N n C O1 M N N- } W J O N N O N N O e-- p 0 } fD C O L c`O L O O O W O O � ` E E o a .-. N o v 9 o� O N UUo O W o C rn Oc C N O M O N O IL 9 cL C _ O 10 O J O 30 ` m V UO —. a o oLL c c u LU r c c ~ o a: E '0 y u c > c F. LOL _. m 7 0 T U c n" %z `0 0 i O N r'o > • 0 UJN Q bE 7 �O `o 2 O OO c O O~ W N G) N O C O }+ x x c w c 0 E rn n> E_ E_ F c 0 t0 m0vco' L >-'F> a LL mO p O ILJa V)LLQ ONmn m°' im ma 1 1 1 1 1 i 1 1 1 1 1 1 1 100-Year Event Concrete Pan Assessment Worksheet for Irregular Channel Project Description Project File j:\projects\06-9009\files\chase-pa.fm2 Worksheet Concrete Pan Assessment Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.005000 ft/ft Elevation range: 35.10 ft to 35.18 ft. Station (ft) Elevation (ft) Start Station 0.00 35.18 0.00, 1.00 35.10 2.00 35.18 Discharge 0.07 cfs Results Md. Mannings Coefficient 0.013 Water Surface Elevation 35.18 ft Flow Area 0.08 ft2 Wetted Perimeter 1.95 ft Top Width 1.94 It Height 0.08 It Critical Depth 35.17 ft Critical Slope 0.007484 ft/ft Velocity 0.93 ft/s Velocity'Head 0.01 ft Specific Energy 35.19 ft Froude Number 0.83 Flow is subcritical. 03/28/06 05:35:12 PM End Station Roughness 2.00 0.013 FlowMaster v5.13 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708- (203) 755-1666 Page 1 of 1 10-Year Event Concrete Pan Assessment Worksheet for Irregular Channel Project Description Project File j:\projects\06-9009\files\chase-pa.fm2 ' Worksheet Flow Element Concrete Pan Assessment Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data ' Channel Slope 0.005000 ft/ft Elevation range: 35.10 ft to 35.18 ft. ' Station (ft) Elevation (ft) Start Station ' 0.00 35.18 0.00 1.00 35.10 2.00 35.18 Discharge 0.04 cfs R FI T H C C V V ' S Fr i FI r 1 c 03/28/06 ' 05:34:48 PM To He Wt Wa We esults d. Mannings Coefficient 0.013 ter Surface Elevation 35.16 ft ow Area 0.05 ft2 tted Perimeter 1.58 ft Width 1.58 . ft 0.06 ft rifical Depth 35.16 ft ritical Slope 0.008066 ft/ft elocity 0.80 ft/s elocity Head 0.01 ft pecific Energy 35.17 ft oude Number 0.80 ow is subcritical. End Station Roughness 2.00 0.013. FlowMaster v5.13 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 End Station Roughness 2.00 0.013. FlowMaster v5.13 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 100- Year Sidewalk'Chase Assessment Worksheet for Rectangular Channel ' Project Description Project File j:\projects\06-9009\files\chase-pa.fm2 Worksheet Sidewalk Chase Assessment ' Flow Element Rectangular Channel - Method Manning's Formula Solve For Channel Depth Input Data Mannings Coefficient 0.013 ' Channel Slope 0.005000 ft/ft L Bottom Width 1.00 ft ' Discharge 0.07 cfs Results Depth 0.06 ft Flow Area 0.06 ft2 Wetted Perimeter 1.12 ft ' Top Width 1.00 ft Critical Depth 0.05 ft Critical Slope 0.007487 ft/ft Velocity 1.16 ft/s Velocity Head 0.02 ft Specific Energy 0.08 ft Froude Number Flow is subcritical. 0.83 r 1 i ILJ e '03/28/06 05:3:38:2525 PM r Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 FlowMaster v5.13 Page 1 of 1 1 1 1 1. 1 1 1 1 1 N 10- Year Event Sidewalk Chase Assessment Worksheet for Rectangular Channel Project Description Project File j:\projects\06-9009\files\chase-pa.fm2 Worksheet `Sidewalk Chase Assessment Flow Element Rectangular Channel Method Manning's Formula Solve For Channel Depth Input Data Mannings Coefficient 0.013 Channel Slope 0.005000 ft/ft Bottom Width 1.00 ft Discharge 0.04 cfs Results Depth 0.0* ft Flow Area 0.04 ft' Wetted Perimeter 1.09 ft Top Width 1.00 ft Critical Depth 0.04 ft Critical Slope 0.008140 ft/ft Velocity 0.94 ft/s Velocity Head 0.01 ft Specific Energy 0.06 ft Froude Number 0.80 Flow is subcritical. 03/28/06 FlowMaster v5.13 05:37:29 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 - Page 1 of 1 1 1 1 1 1 1 1 1 1 1 1 A 1 1 100-Year Storm Swale Assessment Worksheet for Irregular Channel Project Description Project File j:\projects106-9009\files\chase-pa.fm2 Worksheet Swale Assessment Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.020000 ft/ft Elevation range: 35.12 ft to 36.71 ft. Station (ft) Elevation (ft) Start Station 0.00 35.74 0.00 5.00 35.12 7.00 35.12 20.73 36.71 Discharge 0.07 cfs Results Md. Mannings Coefficient 0.030 Water Surface Elevation 35.16 ft Flow Area 0.09 ft' Wetted Perimeter 2.67 ft Top Width 2.67 ft Height 0.04 ft Critical Depth 35.15 ft Critical Slope 0.042937 Wit Velocity 0.15 ft/s Velocity Head 0.01 ft . Specific Energy 35.17 ft Froude Number 0.71 Flow is subcritical. End Station Roughness 20.73 0.030 03/24/06 10:14:26 AM Haestad Methods, Inc. 37. Brookside Road Waterbury, CT 06708 (203) 755-1666 FlowMasler v5.13 Page 1 of 1 10-Year Storm Swale Assessment Worksheet for Irregular Channel Project Description Project File j:\projects106-9009\files\chase-pa.fm2 Worksheet Swale.Asse' sment Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.020000 ff/ft Elevation range: 35.12 ft to 36.71 ft. Station (ft) Elevation (ft) Start Station 0.00 35.74 0.00 5.00 35.12 7.00 35.12 211:73 36.71 Discharge 0.04 cfs Results Md. Mannings Coefficient 0.030 Water Surface Elevation 35.15 ft Flow Area 0.06 ft' Wetted Perimeter 2.49 ft Top Width 2.48 ft Height 0.03 ft Critical Depth 35.14 ft Critical Slope 0.047831 ft/ft Velocity 0.62 fUs Velocity Head 0.01 ft Specific Energy 35.15 ft Froude Number 0.67 Flow is subcritical. 03/28/06 05:35:45 PM End Station Roughness 20.73 0.030 FlowMasler v5.13 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 LEGEND 1—DRAINAGE BASIN 0.844)RAINAGE BASIN AREA (ACHES) A -- DRAINAGE BASIN DESIGN POINT i 2 GRAPHIC SCALE ' 30 0 18 x 60 j $ ( IN FEET ) I inch 30 & x i /J so3s— i En Z O o U O cn IL � � U w w w QQ o U) O Z U Z a NIt w < 2 o g 0 rar 30 E00080H COMA NOTED 1. CONTRACTOR SHALL USE THIS EROSION AND SEDIMENT CONTROL PLAN AS A BASIS FOR CONTROLLING SEDIMENT TRANSPORT FROM THE SITE ADDITIONAL EROSION CONTROL PRACTICES MAY BE REQUIRED. 2. CONTRACTOR SHALL INSPECT THE INSTALLED EROSION CONTROL MEASURES ON A PERIODIC BASIS TO ENSURE PROPER OPERATION. MAINTENANCE SHALL BE CARRIED OUT IMMEDIATELY UPON DISCOVERY OF ANY PROBLEM AREAS 3. THE CONTRACTOR SHALL REMOVE TEMPORARY EROSION AND SEDIMENT CONTROLS AFTER DISTURBED AREAS ARE FINALLY STABILIZED AS DIRECTED BY THE ENGINEER OR THE LOCAL AUTHORITY. 4. TEMPORARY VEGETATION OR STABILIZED LANDSCAPING IS REQUIRED ON ALL DISTURBED AREAS THAT WILL BE EJf "M FOR ONE YEAR OR LONGER PRIOR TO FINAL STABILIZATION. 5. THE CONTRACTOR SHALL REMOVE ANY ACCUMULATED SEDIMENT FROM PERMANENT DRAINAGE AND WATER QUALITY FACILITIES (SUCH AS INLETS, r PIPE.% WATER TREATMENT STRUCTURES. MANHOLES, CULVERTS. DITCHES, CHANNELS, ETC.) DURING FINAL CLEAN—UP. I i x Z GRAPHIC SCALE 15 70 6e ( IN FEET ) 1 Inch = 90 fL. 120 5036" w pan CIE] rm CURB INLET GRAVEL FlLTER CONCRETE WASHOUT BASIN - .........