Loading...
HomeMy WebLinkAboutDrainage Reports - 05/20/20101 I 1 1 1 1 1 1 1 i 1 1 1 1 1 1 m4W City of Ft. Collins roved Plans Approved 13y Date ) —0—Icy FINAL DRAINAGE AND EROSION CONTROL REPORT LINCOLN CENTER ADDITIONS AND RENOVATION 1 I i I FINAL DRAINAGE AND EROSION CONTROL REPORT I' LINCOLN CENTER ADDITIONS AND RENOVATION I I I J FINAL DRAINAGE AND EROSION CONTROL REPORT LINCOLN CENTER ADDITIONS AND RENOVATION Prepared for: City of Fort Collins 700 Wood Street Fort Collins, CO 80216 Prepared by: North Star Design 700 Automation Drive, Unit I Windsor, Colorado 80550 (970)686-6939 May 7, 2010 Job Number 203-36 11 North Star ;nft., design, inc. May 7, 2010 Wes Lamarque City of Fort Collins Stormwater 700 Wood Street Fort Collins, CO 80522 RE: Final Drainage and Erosion Control Report for Lincoln Center Additions and Renovation project. Dear Wes, I am pleased to submit for your review and approval, this Final Drainage & Erosion Control Report for the Lincoln Center Additions and Renovation project. I certify that this report for the drainage design of the Lincoln Center Additions and Expansion was prepared in accordance with the criteria in the City of Fort Collins Storm Drainage Manual. I appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. Prepared by: Troy Si Project I Project Manager 700 Automation Drive, Unit I Windsor, Colorado 80550 970-686-6939 Phone • 970-686-1 1 88 Fax I TABLE OF CONTENTS TABLE OF CONTENTS............................................................................................................... iii 1. GENERAL LOCATION AND DESCRIPTION 1.1 Location................................................................................................................... I 1.2 Description of Property ............................................................................................ I 2. DRAINAGE BASINS AND SUB -BASINS 2.1 Major Basin Description..........................................................................................4 2.2 Sub -Basin Description.............................................................................................5 3. DRAINAGE DESIGN CRITERIA 3.1 Regulations..............................................................................................................5 3.2 Development Criteria Reference and Constraints....................................................5 3.3 Hydrologic Criteria..................................................................................................6 3.4 Hydraulic Criteria.....................................................................:..............................6 4. DRAINAGE FACILITY DESIGN 4.1 General Concept.............................................................::........................................7 4.2 Specific Flow Routing.............................................................................................7 5. 4.3 Drainage Summary ...................................................................................................9 EROSION CONTROL ' 5.1 General Concept....................................................................................................10 5.2 Specific Details......................................................................................................I 1 6. CONCLUSIONS 6.1 Compliance with Standards..................................................................................I I 6.2 Drainage Concept...................................................................................................12 7. REFERENCES..................................................................................................................13 APPENDICES A Vicinity Map B Hydrologic Computations C Hydraulic Calculations D Water Quality and Detention Pond Calculations E Figures and Tables F Floodplain Information 11 n I 1. GENERAL LOCATION AND DESCRIPTION 1.1. Location The Lincoln Center Additions and Renovations project, hereafter referred to as the Lincoln Center, is located in Old Town Fort Collins. This project is located in the southeast quarter of Section 11, Township 7 North, Range 69 West of the Sixth -Principal Meridian, in the City of Fort Collins, Larimer County, Colorado. See the location map in Appendix A. This project is bounded on the north by West Magnolia Street, on the east by the South Meldrum Street, on the south by West Mulberry Street, and on the west by South Sherwood Street. 1 1.2. Description of Property The project consists of approximately 3.7 acres of land. The project site consists of the existing Lincoln Center building, associated drives, walks and landscaping. Access to the existing Lincoln Center parking lot is from Meldrum Street and Mulberry Street. 1 Additional parking for the Lincoln Center is provided by on -street parking on the adjacent streets. The property is used for commercial uses that primarily entail theater productions and ' community entertainment; this building is non-residential and per Chapter 10 of the City Code this structure is not considered a "critical facility". Currently there is a small portion of the existing Lincoln Center building located within 1' the 100 year High Risk Floodplain boundaries of the Old Town Basin, the remaining portion of the site is located within the 100 year Moderate Risk floodplain. The City of Fort Collins floodplain regulations states that if any portion of the building is within the High Risk Floodplain then the entire structure is within the High Risk Floodplain and �i subject to Chapter 10 of the City Code. Per Chapter 10 of the City code, new additions to the the Lincoln Center building must be elevated, floodproofed or removed from the High Risk Floodplain. A CLOMR report has been provided to the City of Fort Collins Floodplain Administrators to revise the limits of the existing floodplain and by making adjustments to the existing topography by pacing fill and revising the hydraulic HEC- RAS model to show that the High Risk Floodplain does not touch the existing building or 1 1 I ithe proposed additions. Immediately upon completion of the proposed fill and prior to 1 building construction an asbuilt survey will be completed and a LOMR will be provided to finalize the floodplain map revision. The study area for this project spans between S. Sherwood Street and S. Meldrum Street along W. Mulberry Street. A master drainage ' hydraulic study has been completed for this area and is documented in the "Technical Documentation for the Baseline Hydraulic Modeling of the Old Town Basin" prepared by Anderson Consulting Engineers, Inc. dated July 15, 2003. With the floodplain CLOMR report the HEC-RAS model, for Mulberry Street Reach 5 between cross -sections 3724 and 3505, is being modified. It is proposed by this project to place fill in the High Risk Floodplain and to show the resulting impacts in the above mentioned HEC-RAS model. Once modeled, the High Risk floodplain lines will be adjusted to reflect the proposed fill. With the proposed fill, the High Risk Floodplain boundaries will move away from the entire building footprint, which includes the existing Lincoln Center and the proposed building additions. Once the fill is placed and the LOMR approved then the existing Lincoln Center building and proposed additions will not be located within the High Risk Floodplain. Removal of the existing building and proposed additions from the High Risk Floodplain releases the 1 Lincoln Center from the requirements of Chapter 10 of the City Code. The foundation for the proposed addition is a spread footing as shown on construction plan sheet C5.2. The minimum opening elevation for the entire structure ranges from 4998.00 to 4998.60. Within the building there exists an orchestra pit where the lowest floor elevation is 4995.20, the lowest flow elevation is below the base flood elevation. During a 100 year flooding event the existing structure continues to be located in the Moderate Risk Floodplain and therefore the building may become inundated by floodwater. If floodwaters enter the building then the lowest floor elevation may become inundated by internal flooding. A dry area has been created near the southeast corner of the building where the addition is being proposed. All elevations given in this report and in the construction plans are based on the 1929 NGVD unadjusted datum. See grading 1 sheets C2.0 and C2.1 for specific location and elevation at each of the building entry points. Stormwater from the Old Town Basin is ultimately routed to the Poudre River in the existing streets and storm pipes in historic flow routes. The floodplain and floodway located within the project area are located within the City of Fort Collins Regulated Old z 1I I I I [J i [1 I 1 I I Town Basin and the City of Fort Collins uses Chapter 10 of the City Code to manage the floodplain. The location of the proposed development is located on the Federal Emergency Management Agency (FEMA) Flood Insurance Rate Map number 08069C0979G dated June 17, 2008. FEMA does not have a defined floodplain within the study area. Existing vegetation on this site consists of mature trees, established grasses and other landscaping. Stormwater runoff currently sheet flows to the adjacent streets and is conveyed in the curb and gutter to the existing storm inlets and ultimately conveyed to the Poudre River. The existing slopes onsite are approximately 1% to 5% to the adjacent streets. Currently water quality and detention measures have not been provided for this development. The City of Fort Collins Master Plan for the Old Town Basin states that lots are allowed to construct up to 5,000 sq.ft of additional impervious area before the City requires water quality and detention. With this project, it is proposed to construct approximately 11,390 sq.ft of additional impervious area. Since there, is a greater than 5,000 sq.ft of impervious area being constructed, water quality and detention is required for only the new impervious area. With this project it is required to detain for approximately 6,390 sq.ft of additional imperviousness (11,390 - 5,000 = 6,390 sq.ft). The proposed detention pond will be located in the northeast corner of the site and will be incorporated into the proposed landscaping. The site has many mature trees that are required by the City Forester to be maintained and protected during construction. There are several existing trees that will be removed due to the proposed additions, beetle kill and disease. The site has been divided into 7 drainage basins to define the area that will drain to the proposed detention pond and to calculate the additional impervious area being constructed with this project. Detention volume is based on detaining the 100 year storm event and releasing into the existing storm sewer at the 2 year historic runoff rate. The detention volume has been calculated using the FAA method as described in the City of Fort Collins Drainage Criteria manual. Due to site constrains detention will be provided for basins 2, 3, 4 and 5. Per the Old Town Basin master plan states that 5,000 sq.ft of additional impervious area is allowed to be released undetained. It has been calculated that in Basins 1, 6 and 7 that there will be an additional 5,072 sq.ft of additional 3 impervious area being constructed and no detention will be provided for these basins. 1 Water quality is required for Basins 2, 3, 4 and 5. Water quality for Basins 2, 3 and 4 will be provided by the use of bioswales along the north property line. Water quality for basin 5 will be provided by the conveyance of runoff through the grass buffer and then further enhanced by the sump in the outlet structure which acts as a sediment trap. The ' bioswale, grass buffer and sediment trap will provide water quality for the entire north portion of the building which includes the majority of the proposed improvements. 11 2. DRAINAGE BASINS AND SUB -BASINS 2.1. Major Basin Description There is a City of Fort Collins master plan for the Old Town Drainage Basin which states that water quality and detention is required for developments that construct greater than 5,000 sq.ft of impervious area. The detention pond has been designed to detain the 100 year developed storm with a release rate equal to the 2 year historic runoff rate. Since this development is proposing to construct an additional 11,390 sq.ft of impervious area then water quality and detention is only required for all impervious area above the 5,000 is being sq.ft allowance, however with this development it proposed to provide some detention and water quality for a portion of the existing land. Along the north side of the building the 100 year runoff rate will be detained and attenuated to the 2 year historic runoff rate. Drainage patterns for the overall site have been improved with the proposed improvements that are constructed with this project. The site is not located within the FEMA designated 100 year floodplain. A portion of the FEMA floodplain is shown on the FIRMette that is located in Appendix D of this report. ' 2.2. Sub -basin Description This northern portion of the site drains overland to the bioswales where runoff is filtered through a sand / peat moss mixture and collected in a perforated pipe. Stormwater is then conveyed to the proposed detention pond. As designed, the outlet structure will allow ' collected runoff from the bioswale to surcharge into the detention pond while the flow control plate in the outlet structure controls the release rate to the 2 year historic runoff. See Section 4 of this report for specific details for each sub -basin. 4 I 1 3. DRAINAGE DESIGN CRITERIA 1 3.1. Regulations Drainage for this site has been designed to meet or exceed the "City of Fort Collins Storm Drainage Design Criteria Manual" specifications, the City of Fort Collins Old Town Basin Master Plan and Chapter 10 of the City of Fort Collins Code. Where applicable, the criteria established in the "Urban Storm Drainage Criteria Manual" (UDFCD), 2001 has been used. This development is required by Chapter 10 of the City Code to obtain a floodplain use ' permit for all structures and site development within the High Risk 100 year floodplain. 3.2. Development Criteria Reference and Constraints Stormwater runoff from this site has been routed to conform to the requirements of the City Stormwater Department. Detention is required for this site and is being provided for the northern portion of the development. Runoff for the remaining site is allowed to drain in historic flow routes. Water quality facilities are required for the additional 1 improvements and are being provided by the grass buffer, the proposed bioswales located along the north property line and the sediment trap located within the outlet structure. The grass buffer will slow runoff and promote settling of the suspended sediment. The bioswale will filter stormwater through a sand/peat moss mixture prior to conveying runoff to the underground storm pipe. The 2.0' sediment trap within the outlet structure will allow any collected sediment within the north portion of the site to settle out prior to being released in the existing storm system. C I 17 I 5 Due to site constraints, a variance is requested to allow the detention pond to have 0.10' 1 of freeboard from the calculated 100 year local drainage water surface elevation to the top of berm elevation instead of the IN that is typically required. The existing building and proposed additions are located a minimum of 1.40' above the 100 year local drainage water surface elevation. The detention pond has been designed to detain the 100 year storm site runoff without overtopping the banks. If the detention pond reaches capacity, ' then any additional stonnwater will overtop the pond embankment and will flow to the adjacent streets in historic flow routes. The spillway for the pond shall be along the entire length of the pond embankment along the north, which has been measured to be 330 linear feet. If the entire 100 year runoff is allowed to overtop the bank then the flow depth has been calculated to be 0.03' deep with a velocity less than 0.50 foot per second. Since the pond is not anticipated to overtop and overtopping flow depth and velocity is very small, the established vegetation and landscaping will provide sufficient erosion Icontrol measures and no additional armoring will be provided. 3.3. Hydrologic Criteria Runoff computations were prepared for the 2 year and 10 year minor and 100 year major storm frequency utilizing the Rational Method. All hydrologic calculations associated with the basins are included in Appendix B of this report. Water quality has been provided by utilizing methods recommended in the "Urban Storm Drainage Criteria Manual". See Appendix D for water quality calculations. ' 3.4. Hydraulic Criteria All hydraulic calculations within this report have been prepared in accordance with the City of Fort Collins Drainage Criteria, Urban Area Drainage Criteria Manual and are included in Appendix C. This project is in compliance to the Chapter 10 of the City Code adopted by the City of Fort Collins. Immediately upon completion of the proposed fill and prior to building ' construction an asbuilt survey will be completed and a LOMR will be provided to finalize the floodplain map revision. I. 6 I 1 4. DRAINAGE FACILITY DESIGN ' 4.1. General Concept All of the runoff from this site historically sheet flows to the adjacent streets and is ' intercepted by the existing inlets located near the northeast corner of this site. With the construction of these proposed improvements onsite stormwater will be detained and then ' released to existing flow routes. Historic flow routes will be maintained to the greatest extent possible. ' 4.2. Specific Flow Routing ' A summary of the drainage patterns within each basin is provided in the following paragraphs. Basin 1 is located along the west side of the site. This basin includes sidewalks, a portion of the existing landscaping. Runoff from this basin will sheet flow west to the existing parking lot. Water quality for this basin will be provided by runoff flowing through a grass buffer prior to being conveyed to the existing parking lot. Due to site constraints detention is not provided for this basin. It has been calculated that this basin will contribute an additional 770 sq.ft of additional impervious area to the existing streets. Basin 2 is located in the northwest portion the site. This basin includes roof area for a portion of the existing building and the west side addition. Water quality is provided for ' this basin by routing runoff to the sediment trap located in the outlet structure. Runoff entering the sediment trap is slowed so that suspended sediment may have a chance to ' settle out prior to runoff being conveyed to the existing storm sewer. In the event the drain basin becomes clogged or reaches capacity then runoff will surcharge the bioswale inlets and ultimately overtop the detention pond banks and sheet flow to the existing curb and gutter in West Magnolia Street. From there, runoff is conveyed east to the existing storm inlets in historic flow routes. ' Basin 3 is located in the northwest portion the site. This basin includes a portion of the existing building and associated landscaping. Runoff from this basin sheet flows north to ' the proposed bioswale. Water quality is provided for this basin by routing runoff to the bioswale and being conveyed through the sediment trap in the outlet structure. Runoff ' entering the bioswale will infiltrate into the ground and will be intercepted in the proposed storm pipe and conveyed underground to the proposed sediment trap. In the 1 I event the drain basin becomes clogged or reaches capacity, runoff will overtop the ' detention pond bank and will sheet flow to the existing curb and gutter in West Magnolia Street. From there, runoff is conveyed east to the existing storm inlets in historic flow routes. ' Basin 4 is located in the north central portion the site. This basin includes a portion of ' the existing building, a proposed addition, the outdoor theater and associated landscaping. Runoff from this basin sheet flows north to the proposed bioswale. Water quality is provided for this basin by routing runoff to the bioswale and being conveyed through the sediment trap in the outlet structure. Runoff entering the bioswale will infiltrate into the ground and will be intercepted in the proposed storm pipe and conveyed underground to ' the proposed sediment trap. In the event the drain basin becomes clogged or reaches capacity, runoff will overtop the detention pond banks and will sheet flow to the existing curb and gutter in West Magnolia Street. From there, runoff is conveyed east to the existing stonn inlets in historic flow routes. Drainage for the outdoor theater is provided by several drain basins located on either side of the stairs leading to the stage. The inlets are located in sumps and it is anticipated that during a heavy storm event there may be some minor ponding over the drain basins. All captured runoff is conveyed to the proposed sediment trap that is located in the detention pond outlet structure. Basin 5 is located in the northeast portion the site. This basin includes a portion of the existing building, a portion of the proposed addition and associated landscaping. Runoff ' from this basin sheet flows north to the proposed detention pond. Water quality for this basin is provided by runoff being conveyed through the grass buffer and then further ' enhanced by the sediment trap that has been designed into the outlet structure. The detention pond will detain runoff to provide the required detention. In the event the ' detention pond reaches capacity, runoff will overtop the detention pond banks and will sheet flow to the existing curb and gutter in West Magnolia Street. From there, runoff is conveyed to the east to the existing storm inlets in historic flow routes. Due to site constraints the detention pond has been designed to have 0.10' of freeboard. The sediment trap provides water quality for basins 2, 3, 4 and 5. This sediment trap is located within the outlet structure and will allow sediment settle out prior to stonnwater being conveyed to the existing storm sewer system. 1 8 ' Basin 6 is located in the northeast portion the site. This basin includes a portion of the existing building, a portion of the proposed addition and associated landscaping. Runoff from this basin sheet flows east to Meldrum Street. Water quality for this basin is provided by directing a portion of the roof drainage to the sediment trap and the ' remaining runoff shall be conveyed to the proposed tree wells and through the existing grass buffer. Once the tree wells reach capacity then runoff will overtop the well and ' sheet flow through the grass buffer to the existing curb and gutter in Meldrum Street. From there, runoff is conveyed to the north to the existing storm inlets in historic flow routes. Runoff collected within the tree wells will infiltrate into the ground. Due to site constraints detention is not provided for this basin. It has been calculated that this basin will contribute an additional 2,255 sq.ft of additional impervious area to the existing streets. Basin 7 is located along the southeast side of the site. This basin includes a portion of the ' existing building, a portion of the proposed addition and associated landscaping. Runoff from this basin will sheet flow south to the existing parking lot. Additional water quality measures are not being proposed for this basin and runoff is allowed to flow in historic routes. Water quality for the overall site is enhanced due to additional water quality ' measures being provided along the north side of the building. Due to site constraints detention is nou provided for this basin. It has been calculated that this basin will contribute an additional 2,047 sq.ft of additional impervious area to the existing streets. 4.3. Drainage Summary ' Drainage for this site was designed to conform to the City of Fort Collins stormwater and floodplain requirements. Water quality is provided for the north portion of the site which includes basins 2, 3, .4 and 5. Water quality is provided by routing runoff through the grass buffers, the bioswales and the sediment trap. Runoff that is within the drainage basins and that has entered the perforated pipe located under the bioswale will be routed ' to the proposed sediment trap that is located within the outlet structure. Within the outlet structure there is a flow control plate which will restrict the release rate to the existing ' storm system to the 2 year historic flow rate. During a heavy storm event, collected runoff from the bioswale will be greater than the controlled release rate, therefore the collected runoff from the bioswale will surcharge the outlet structure and stormwater will be detained in the proposed detention pond. The outlet pipe for the proposed detention pond is connected to an existing inlet in Meldrum Street which is located on the southwest corner of the intersection of Magnolia Street and Meldrum Street. E iL ' For this development, the High Risk Floodplain will be revised with the City of Fort Collins LOMR process to show that the existing building and the proposed additions are solely located within the created Dry area and the Moderate Risk Flood zone. Since the existing structure lies within the Moderate Risk Flood zone then the requirements stated ' in Chapter 10 of the City Code are not required and therefore floodproofing is not required. If in the future it is required to floodproof the building, it will have to be ' protected 0.5' above the Base Flood Elevation (BFE). This minimum floodproofing elevation is called the Regulatory Flood Protection Elevations (RFPE). Currently the ' RFPE for this building is at an elevation of 4999.50. It also should be noted that the City has future plan to increase the size of the existing storm sewer to convey the 100 year storm event from the Old Town Basin to the Poudre River. Currently this capital ' improvement project is only planned and there is no estimated time of construction. Drainage facilities located outside of the right-of-way (including the grass buffer, the bioswale, proposed storm drain systems, and the detention pond outlet structure) will be maintained by the owners of the property. It is anticipated that sediment will collect ' within the sump located within the outlet structure, collected sediment will need to be periodically cleaned. During construction the outlet structure shall be visually inspected at a minimum of once a week for collected sediment and cleaned if the depth of sediment is greater than 6 inches. After construction and once the vegetation is considered established, then the outlet structure shall be visually inspected once a month until a maintenance schedule can be created. The maximum allowable time between visual inspections shall be 6 months and the maximum allowable depth of sediment ' accumulation is 1.0 foot. 5. EROSION CONTROL 5.1. General Concept This site lies within the Moderate Rainfall and Wind Erodibility Zone per the City of Fort ' Collins. Potential also exists for tracking of mud onto existing streets which could then wash into existing storm systems. See drainage and erosion control plan for measures taken control the movement of sediment off site to the public streets and existing storm sewer system. ' 10 'J i5.2. Specific Details ' To limit the amount of silt leaving the site, several erosion control measures shall be implemented during construction. All inlets (existing and proposed) shall be protected with gravel filters or wattles, wattles will be placed in the existing curb and gutter used where appropriate and silt fence shall be installed along the north property line and along ' a portion of the east and west property lines. The outlet structure will have a 2.0' sump constructed and will act as a sediment trap during and after construction. Due to the existing project site conditions, all construction traffic will be on paved surfaces and ' therefore a vehicle tracking pad is not being proposed, however if vehicles access public roads and there is a potential for mud tracking, then a vehicle tracking pad will be ' required at the access location and mud will be removed from the street on a daily basis. During demolition and site construction, all disturbed areas are to be kept in a roughened condition and watered to reduce wind erosion. If the area remains bare for longer than 30 days and is not being worked on, temporary vegetation is required and shall be planted to help reduce the potential for soil movement. The detention pond and outlet structure shall be used to collect sediment during construction and prior to final seeding of the detention ' pond, collected sediment shall be removed and the pond shall be graded to final design elevations. 6. CONCLUSIONS ' 6.1. Compliance with Standards All computations that have been completed within this report are in compliance with the ' City of Fort Collins Erosion Control Reference Manual for Construction Sites and the City of Fort Collins Storm Drainage Design Criteria Manual. ' 10 City Code by City This project is in compliance to the Chapter of the adopted the of Fort Collins. 11 I i i 1 1 1 1 1 1 1 1 1 1 1 6.2. Drainage Concept The proposed drainage concepts presented in this report, and on the construction plans, adequately provide for stormwater quality treatment for the proposed improvement. Conveyance elements have been designed to convey required flows to the proposed detention pond and to require minimal future maintenance. If, at the time of construction, groundwater is encountered, a Colorado Department of Health Construction Dewatering Permit will be required. 12 7. REFERENCES 1. City of Fort Collins, "Storm Drainage Criteria Manual", (SDCM), dated March 1999. 2. Urban Drainage and Flood Control District, "Urban Storm Drainage Criteria Manual", Volumes 1 and 2, dated June 2001, and Volume 3 dated September 2001. 3. "Technical Documentation for the Baseline Hydraulic Modeling of the Old Town Basin". Prepared by Anderson Consulting Engineers, Inc dated July 15, 2003, project number COFC 14.1. 4. City of Fort Collins Floodplain maps. Supplied by the City of Fort Collins, printed on October 19, 2009 5. Chapter 10 of the City of Fort Collins Municipal Code, published by "Colorado Code Publishing Company", dated 1987. Reference hnp://www.colo6ode.com/fcmuni/ftemuni IO.pdf J 13 I 1,� APPENDIX A I 1 VICINITY MAP I I I I I I I i I I i I OAK ST i E U� 0 0 0 ry W DATE: 11/11/2009 SCALE: N.T.S. DESIGNED BY: TDS JOB NO.: 203-36 MAGNOLIA ST I MULBERRY ST i I LINCOLN CENTER EXPANSION VICINITY MAP i— Un z 0 cn Q r-- I MYRTLE ST FM IF] SHEET 1 OF 1 North Star "I--- design, inc. 700 Automation Drive, Unit I Windsor, Colorado 80550 Phone: 970-686-6939 Fax: 970-686-1188 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 APPENDIX B HYDROLOGIC COMPUTATIONS 1.2 I 1 1 1 u 1 1 J \ TWOONA, t4 ICO YEAR BOUNDARY D e(BuRr RODDWAY IRO YEAR WYL KWMA1 .990.)J (2 -� UNOEI.RAM a�rAr� w ®OIa CALL UTILITY NOTIRCATON CENTER Or COLORADO 1.800-922-1987 GALL 2-W9NESS DAYS IN ADVANCE REFORM YOU OG, GRACE OR EXCAVATE Fw GAL NARKRG OF UNDERGRWN) KNOBS YOUTHS Y ♦♦ I 0.10 0.9 ♦♦ I............ 0 r- 1)mWXf ISO YEAR WSiL 9%)1 BIOSWNL MM PERFGRAIEO WWI u S I c 11,1111,1314" STREET WI w 9RS� - :OO lEAR W$ 996 )J Csr- SE9 naaNG A.oGETWEll ME I \ 4 ' BABY 5 0360.47 L�\ EXISTING BUILDING ♦♦_ EXISTOEG BULDING a� ps 1>E r0 Pf a Lot i 41, �. n^ \ 5 LLED BDuxDARr i ♦V, G.3S G. V HIGH INE RISK HIGH RISK ♦♦ BOUMOMOARIWS, 41,♦ IA / All, / •♦ 41, I SEE /�vsSi A II II r I�MIOpVLAY_ 9 30 15 0 30 60 M IIII SCALE: 1' n 30' 0 II LEGEND Feee _U ■ _ ..._ _.._ _ Q CE9w PONT EnSRND PF'ES PROPOSES 5)diY WEGWSWO 1 �. We"A � I cN1ENA - O.M 0.9 5 M RUNG? COCIFFRUENT GO FEARED CND SECTION AREA Al ACRES E051wC 5' CONTOUR Z Q P I 1 I i I _ _ ._. -' - EUS)WG I' CONTOUR FLOW uuttcllw NOW Ree m ® DAMN BOUNDARY �Ap05 FgOPOYO S' Cw)OIR 1 „ W - I O L l II II :. PRCPOSCD V CONTOUR SF -SF- SALT FENCE 55FFW1 '® WARLE ® )`w(' lj [ONSPIUCnw ENTRANCE INILT PROTECTION STANDARD EROAIT AND SCONWr Cw0. TRCONSTRUCTION RN1 NOTES I. n..m. r w w: • -1 rnnr vnie. wr w .. w. •• m'«wrl...• rNr Ya. L IFwnw a« OA, We. �a r---...II .....n ~ ri `.,. Y a. �v.:.a-r.NL.w F .q..www._^ev waa.war_I •+•� AA N AA FgW^w MIN nwrw N..r..nlp « ewn-wF w-Ya •rrr w+y ..a..r w Frw.l. A Pr«Fw rn- wr .r nuw•w 4 M « ww • www Av .F .w �r`-n Fr e� ..� .. r .wnr w nl..r .:w.w rr. F.:.... a.rwe. M nNw -anal- ..a r .�ww r. � ,^ V, Z � f/x � J U O U Y! J J O U I I NI've -•N�n r...F. a W - WANne.I -I. «a. « I. n. a Anl .nIN .. e Ann . raa ru rr.ln nlMa Gwr•c v.R-.n O.w.rl«�Tnm �lNrPnc) Ar . wl H . �.W�f -tea '.n : . �>% Q fyA O II IIC p L2E b �.Frw..A.• , n n..�. -.— ve,AWN I, LAW Aw.m.W A, W a1rR«a .A. Y Len WALL. - u 1 �a wMM n .. . • An. �..++.•.- w L�1 .... «.rwv new.�rN.:+e « F �'A. .,II:.w�na: Avn ^~ . .e« �nlr«... •b Nn NY N. Net. wrlNnF nY.n A. Yun•4e F A. Level"I'vent'veentent-ALLIA-YA.-.-A'.. Letw.•"°:S :•» : rin..:`w M F.wr. «...rti N. -....-Y. w ran •..: ANA, .Yn'^.. -:-w .". "^ :..Nr: a'•.`"«w.nr M.....w «rwr.r.n•.r r. =,vII-IS Q LL W LL LL O It-O U O LL Z ' r AL F I IIii II II II IS W / BIG O _ • rn"Ma n. IN, .•wI M ^.r IS) .� rr rr -+ r. wr .LAW•n.rw 1.1-N.r.M�. r...««n•.w, L.NA Ane Aeelve .."n-�`r., nra , - �r a p +F nsa. •n ..rnn „w �k n L P, uwn. � It ti„. (OWS) - w- LHP.S ..w. I-aa NFIwa . INF. WA w M Mn.w :.�, n.rw.. _n«. ; n. . , AN veneve ro- -N F env On LIP -'r F^ wr'•. Avev, "we venen:nIA, LAN, uvAWPv I vvvv, .�r "Sent tF ewwl. ong Narnw _ w gF.ti rnee. (W ve anw F" w. r..rr .r. An. exawnnN, even, evetne aNnr. LW« ur. aIr u.N On, ON, I. .w .an MG AM .msr .sw- SEAL .r An � Z W Z ' ES V Q � - YATw PgNT I PRC[Ci NOI ' MALIGN PONT AN BEAT -AS 1,� Cn5 AA Nr v xC T ' RIXDPLYX (BOUNDARY (M) 1AABERRY BASIN SUMMARY TABLE BASIN DESIGN PANT AREA C. M D. Or I I BOB 0.44 50 0.1 0.5 2 2 a.10 0.90 &C, 0.4 0.7 ] ] O.16 Du 10 0.4 1., A A 0.36 0.52 5.0 L1 2.3 5 5 0,35 00 50 L0 2.3 6 a D.J5 055 SO IS 11 2 ) 1.02 0.)] 5.0 17 ).a O ' U MOMS ^ ALL TEMPORARY AND PERMANENT ERMIDr1 AND SEDIMENT CwM0. PRACMES SNALL BE ..T.M wD REPAIRED BY ME OWNER WRNG ME CONSTRUCaw PHASE AS NEEDED MI ASSURE CONTROL PERFwYANCE DF Z NEW INTENDED TUNCTw, WATTLES MAY RESUME PERIODIC REPLACEMENT AND ALL SEgMENI ACNWLAMp - BEMNO MEN MUST 0E REMOVED AND DISPOSED Gi PROPERLY. ALL FACIUTES MUST BE INSPECMO 0Y MC ER•LINGLE•MASSE 1 I OWNER OR DOWER'S REPRESENTATIVE FQL G EAw HEAVY PRECUryTATw w SNOW WELT EWNT MAT RESULTS O ARCHITECTS IN SLAW. 2. WRRENRY MIS BURRING IS LOCATED W ME OTY OF FORT Cp1N5 HIGH AND MODERATE RISK ICI YEAR I FUMPLAINS. A CIDMR REPORT 15 SEND PREPARED C URRENMY NM TINS PROWECT TO RACE Fell R VNE O FLWD FRRDE TO MOONY ME FLDCOPLAR MUNDARIES ONK1 ME LOSER IS APPROfED AND ME FRL IS N RACE, MEN THE UNCOIN WATER BULDNB CALL BE REYDVEO FROM LM Mw RISK ROOOR-YN HOOEN.O, ME ' ERISTNL BIDING NIL REYNN MMIN TNE YODCRAM RISK RLCOPLAIN. WRING A ISO YEAR STORM MERE IS 11 1y FnW1MLEN5 WAY 6UlE. 61W FMTOD UNS.GO WMe SML A UTAMCE ME BOWING MAY RCN, AOne, MSWmIr J. ME BASE RDCO ELEVAT101 CF ME SOLD! NO IS AMD FI-NCVD. ME REWGTCRY ROW PROTECTNM REVATw K 49995 FT-MrM FOR ANY NEW ADDITIONS MAT WE CCNSTRUCMD w STRUCTURES LWAMD WMIN O ME nw RISK ROOD BOUNDARY. NOfth Star A ME OWNER SHAL WTAIN A ROWPLYX USE PERMIT FOR ALL STRUCTURES AND SITE'RORR NNN IW , OMigIT.NG, ROWRNN. PRIOR TO CONSTRUCTION WON IMMUDES SMUT WORK. 90EWAA; CURB ! SUTTER. LANDSCAPING AND ANY OMER DMIAWMENI DEfNEO BY CLAW" 10 OF CITY GWE rR OM wI wyu. fm-ya NyyP DETENTION POND SUMMARY TABLE 1pp-M lro-M RELEASE PEON YIMMUM CE)ENIIW OUSEL RAZE EDIIIRQ BANK vIXUYE dNiTCE ELEVATION SIDA cfr.11 A9%.)] 1,1A ch A.AO M A9B0.95 . ME ENTIRE 9M IS LOCATED w A ISO YEAR OM1 ROW WAY - .51"AMD ROWPLAIN. ALL SITE WOK, BOWING CdKMUCnw. AND OMER DEVELOPMENT MUST MEET ME RCCURCMENTS DF wAPMR 1. a MC OTY cWE 6. SEE XOMR REPORT AND LOUR FOR ADDI INFORMATION w ME LIMITS W ME HLN W5( RDDDPLNN DUE IS ME PROPOSES SITE MPROVEYENTE ). SEE OETA1 SHEET C5.2 FOR DEIAE fY YCMM A -A. fWNNTEN CROSS SECTION. 6. IMMEDIATELY YPw COYPIInw OF ME PROPOSED PIRfOKMENI5 XCAR ME SWMEASI ELEVA14w SUMMARY LABIE fOR SOIIMEASi AOOTIw ADISOW, FN ASSORT $URYEY SHALL BE CO Sl BASE ROOD ElEVAIIw A99),I w ME IYNMVEYAIS TIC LOyq y.All OE WINNOWS ID RENDVE ME ELTSONG DOWLeC AND LOWEST fLOdf f1FVAnw A%5.2 PROPOSED ADNMw FROM ME IPw R % FWKOPLAN PRINT To BEORnIG CONs1NUCTNN w M PROPOSED AODINDLA uwwuM Hv6c fLEv6nw w9za MINIMUM OPENING (MO) "9 00 rPr-aAIPPeaun DRAINAGE &EROSION CONTROL PLAN R C4.0 1 1 ul 11 I 1 .! I V C W �CO om F co wm L -0 m F U Q 0.. ; U N OU z rn O F cn } O a m N N r o m m 0 m m is r m m w m r m m m r m 0 0 0 0 0 0 0 0 0 0 o 6 o 0 o c o o c u U Ix } M N a a a r N a m a m Ip r m p 0 0 c; 0 0 0 0 O O c; 0 0 06 6 0 0 0 0 ci U m m P Q a a m m a a m a N a r m � a 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 U N N Q a M m a m M N a N r P U G G G 6 6 O 0 0 ci ci 0 0 0 0 0 0 0 6 O U 0 m W 7 F- .Z o e h m m m 0 0i o m m o o?v, O� O m N a N f7 (h m r m O O m a N m r W a Q {7 m 1p l(l N N m tp N N N r m r m r m L G O _ U w� a V¢ a C, a m Q iO N r Q J LL Q N M M N O O N N N N O m O O N N th Q N U Z W n O w N N m m a N N P O N N r m m W NG Q �- N n �n N w n a a N m W R' F- N N t7 m m UI -1 N A P N OI m Ip N) N ^ a O J Q W y m O m m m v1 N r a m O m m m m N r a O m x N S N o Z q Z O 00 W Z N t7 a j mi a N M Q N m r Wp a E y O N 2 O N C y W O N O L o in 'w o 0 I EE m m z 0 1 I c a 2 a n _O Q~ c K C f i w N w 04 E Z J O U LL. w F z W a O ' a w W A Z O F a W z O` W � > N W G 6 S = O o F Q C Z c m O c 'yo Vi Z y aOm p ar°'i Z�am m Q F Lv� 0m 0 0 a C UU N Y K rc J Z� E ui N VI N N N N N N N Vl N N Yf N N N N LL O O C m N N N A m (O 10 M t7 N N N A N 1p tp (�1 [7 2E O O O O O O O N N O O O O O O O N N Q II m -y- O u N Q J W N N P O O O O N Q O O O O 'WS '� 00! OOi OOI N 001 001 u � y Z Y Q E W K o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o O V= C UI Yl N N N N N VI N N N N N N N N N N y 0 �z E n � rnrnmmmmQm rn nmQmQN.-N �n lh (7 M IO Q N N N N l7 l7 N Q N N N N O E M N M P N P P 01 rn Cl m t7 t�l Q N P P 01 rn 3 ^ O O O O O O O N N O O O O O O O N UI O > LL J W 2 p`� > O O O O O O O O O O O O O O O O O O Z Q O O V 00 O O N N O O N N O O N N O O N N O N O N O O N N O O N N OOO N N N O N U � a L LL LL LL LL LL LL LL d LL LL LL LL LL LL LL LL LL W 1� T. H U x x x x x x x x x x x x x x x x x x W O m 0 0 P 0 0 P P 0 0 P P 0 o P t7 O l� O P O O P Q O O Q O O O P P O t7 o N f J t W rn O O O O O O O O O O O O O O O O O O F ^ J _ c�D mm on 0 o omoPmNnm m E �- N- N N Cf 1�1 ry N a _ xxxxxxxx x xxxxxxxx x y N N (V N N N N N N N N N N N N N N N z L 5 i c e o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O _ W U m N 6 0 0 P P 0 0 P P 0 0 m a 0 0 P O P 0 01 Q 0 0 N Q 0 0 N A 0 0 (O 0 N O z F m rp O N N 0 N N A P C.?0 m m m m N N mO A Q Q O z z m U O LL N � m P m P N � ' m`- N m N C N P N m A W m Q i i i 2 2 2 2 m O O O D O O a = m U m V y m m m m f S 0 Q Qm N 0 a Q m U 0 W LL 4 U m N a 11 CD ww In W 3 � ow ' N a. a. w O W x 2 W J ¢ z �o ' O Q H N I� �I I U C O C � ' ( O N O O 0 rM cu U o 00 s � m c O 0 rn m 0 0 N N N a E 0 Z Qa a0 O F A Fzp.�r. U r C 00AUvA fN Y ¢ ui W V' V' O O tO (O O 00 co N V' m M (+� U O N V V M W N O N N OO IT 47 O m V O O O O O O— M O O O O O O N M t N O N N LO OO tO to LO to tO OO OO LO OO LO co co 00 OO W W CO W W co co W W W W W W W C N N N N N N N N N N N N N N N N N N C 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 O E vi vi in 0 in (ri ui vi 16 0 Lo vi u7 in (ri vi W IT M W m m W V' N N n co U N V' V M M M (0 V M M W M 0 V n O0 V' 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 O O V' O O � .- M M M O 'IT q O O O O O O— N O O O O O O— N LL U. j c ix rn V 0 W n '- N M V OO W n a U o W K 0 0) 7 M N C a C � N W LLI N M v 0 W n o N M R W n m ¢ o x x x x x x S m 0 0 0 0 0 0 u al v O U O (1 y O N O S 2 a d 0 Q 0 Z IL9 LLI K tq = W 0 ❑ W 2 U Lu F O i LL rn ❑ W O c9 _ QZ W J ❑ Q Z O O Q~Q F K U) — to Y Q w W LL' V a U �Mvmrnao�m �n �vv�oonl� rn a 0 0 0 0 0 m (O (V 0 0 0 — M N _ oo eo m m ao au co ro ao m ao w ao co ao ao 00 v v v v v v v v v v v v v v v v v v O O O O O O O O O O p O O O O p a o p 10 O a0 It O 10 O N O N O O 7 n M (n lnvva r� (n 't Inrn vminml- co In V o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o w O w o0 m (O N 1 V (O O w N w 0 N r V U LL LL O Z m N M V(O (p h w o a Ir 0 � d v CO N (n a)N w C C C W 0 O r wm N xxxxxx= N M V 1!1 (O t� lL o❑❑❑❑❑❑� N M V Q ❑ m , O U O O. n o o n N N ❑ ❑ 0 w O N rn m a W � LLJ � U O N CL N O W m ¢ W Z 1 I c - o c LO 0)o �COrn C p M @U(D m =C c p Z rn J Z 20 a: H 0 m 0 0 N N N a E O Z N Y a W M M a0 M U) V; O h V O M 0 O d U O O N N N h 0 (O O .- e- (li N N W n 1� - L (A m tt) m (n m LO m 0 m U) O LO m (n m U) O (n m Ln m m m m m O m m 5 m m m m m m m m m m m m m m m m m m C O O O O O O O O O O O O O O O O O O E NuiNvivi vi(ri6 L6 66666666 ui O I� O M N r O N M w N 0 7 m N N I� (n to (o 0 (o (0 (o (o (o m (0 (o U o o 0 6 6 o 6 0 O O O O O O O O O O U (O O aD w m( N 1, V (O O m co co ¢ v O M M M O V o O .- M M M O V O O O O O O O U. LL O Z Ir I m 15 () u1 'p .- N M V (O (O f- M V (O 1� Lu o a O Ui tq d a � (� M N C C N y N N M 'Q to (O t` lL rn N M R to o r LLl N 2 N O U 2 N O N O 'x n w o w N CD fU a I 1 i 1 1 1 1 1 i 1 1 1 1 1 1 APPENDIX C HYDRAULIC CALCULATIONS 1 C Cross Section for Perforated Pipe Project Description Friction Method Manning Formula Solve For Discharge Input Data Roughness Coefficient 0.010 Channel Slope 0,45 Normal Depth 3.90 in Diameter 4.00 in Discharge 0,18 cfs "�KkmJLM CO�Pgc(iy Cross Section Image V: i N H1 Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster (08.11.00.03] 11/9/2009 3:14:02 PM 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Cross Section for PVC pipe Project Description Friction Method Manning Formula Solve For Discharge Input Data Roughness Coefficient 0.010 Channel Slope 0.45 % Normal Depth 17.70 in Diameter 18.00 in Discharge 9.64 cis Cross Section Image V:1 N H 1 Bentley Systems, Inc. Haeslad Methods Solution Center Bentley FlowMaster [08.11.00.03] 1 Ili 212009 3:22:14 PM 27 Siemens Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 I 1 1 1 I I I II II II Cross Section for Outlet pipe Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.013 Channel Slope 2.15 % Normal Depth 3.51 in _ Diameter 15.00 in Z14�f'a- Discharge 1.14 cfs — �✓11 r[Cif qS` K. 0111 .A 'r ,may "ONO V 1 H. 1 Bentley Systems, tnc. Haestad Methods Solution Center Bentley FlowMaster (08.11.00.03] 11/12/2009 3:24:35 PM 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 II Cross Section for bioswale ' Project Description Friction Method Manning Formula Solve For Discharge ' Input Data Roughness Coefficient 0.045 Channel Slope 0.50 % Normal Depth 6.00 in Left Side Slope 6.00 f lft (H:V) (] � Right Side Slope 6.00 ft/ft (H:V) 'S .�;¢ Cn Pl C ' - I Bottom Width 2.00 ft C3 W ' Discharge 267 cis J ���� l STO 2Y� Cross Section Image, T ' 6 00 in 1 1 1 ' 11/9/2009 3:40:51 PM V.4 L H 1 Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster [08.11.00.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA .1-203-755A666 Page 1 of 1 1 APPENDIX D WATER QUALITY AND DETENTION POND CALCULATIONS 10 LOCATION: PROJECT NO: COMPUTATIONS BY: SUBMITTED BY: DATE: Equations: MINIMUM DETENTION VOLUME REQUIRED FAA METHOD Lincoln Center 203-36 TDS North Star Design, Inc 11/12/2009 Qp = CiA V; = T*CiA = T*Qu Vo =m*QPo*(60*T) S=V; -Vo Rainfall intensity from Larimer County Area l IDF Curve A trib. To pond = 1.04 C100 = 0.67 Developed C*A = 0.70 QPo = 1.14 tc = 5 acre acre cfs t ZKrL d mint Rita S�- Storm Duration, T (min) Rainfall Intensity, i (in/hr) Qo (CIS) Vol. In V; (ft) Outflow Adjustment Factor, m Vol. Out V. (ft) Storage S (ft) Storage S (ac-ft) 5 9.95 6.9 2080 1.00 342 1738 0.040 10 7.72 5.4 3228 0.75 513 2715 0.062 20 5.60 3.9 4682 0.63 855 3827 0.088 30 4.52 3.1 5669 0.58 1197 4472 0.103 40 3.74 2.6 6254 0.56 1539 4715 0.108 50 3.23 2.3 6752 0.55 1881 4871 0.112 60 2.86 2.0 7174 0.54 2223 4951 0.114 70 2.62 1.8 7668 0.54 2565 5103 0.117 80 2.38 1.7 7960 0.53 2907 5053 0.116 90 2.22 1.5 8353 0.53 3249 5104 0.117 100 2.05 1.4 8571 0.53 3591 4980 0.114 110 1.93 1.3 8876 0.52 3933 4943 0.113 120 1.80 1.3 9031 0.52 4275 4756 0.109 130 1.60 1.1 8696 0.52 4617 4079 0.094 140 1.40 1.0 8194 0.52 4959 3235 0.074 150 1.20 0.8 7525 0.52 5301 2224 0.051 160 1.15 0.8 7693 0.52 5643 2050 0.047 170 1.10 0.8 7818 0.51 5985 1833 0.042 180 1.05 0.7 7902 0.51 6327 1575 0.036 Required Storage Volume: 5104 ft3 0.117 acre-ft 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Northstar Design, Inc 700 Automation Drive, Unit I Windsor CO, 80550 (970) 686-6939 Proposed Water Quality - Stage/Storage LOCATION: Lincoln Center PROJECT NO: 203-36 COMPUTATIONS BY: TDS SUBMITTED BY: North Star Design DATE: 11/12/2009 V = 1/3 d (A + B + sgrt(A"B)) where V = volume between contours, ft3 d = depth between contours, ft A = surface area of contour REQ. 100 YR DETENTION VOL. = 5104 ft3 Stage (ft) Surface Area (ft') Incremental Storage (ft) Total Storage (ft) underground storage 760 4995.15 0 4995.20 50 1 761 4995.30 125 8 769 4995.40 580 32 802 4996.00 2524 863 1664 4996.50 5530 1965 3629 4996.73 7114 1475 5104 4996.80 7562 485 5589 Volume in pipe Diam. 18 in Length 422 ft Volume in pipe 746 ft3 Volume in outlet structure inlet size 2.0 ft Depth 3.5 ft Volume in structur 14 ft3 Total underground storage provided 760 ft3 Detention Stage -Storage --100 year WSEL -- Top of Berm (assumes square inlet) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 100yr ORIFICE PLATE SIZING Detention Pond Outlet Sizing (100 yr event) LOCATION: Lincoln Center PROJECT'NO: 203-36 COMPUTATIONS BY: TDS SUBMITTED BY: North Star Design, Inc DATE: 11 / 12/2009 Submerged Orifice Outlet: release rate is described by the orifice equation, Qa = C.A. sgrt( 2g(h-E,)) where Qo = orifice outflow (cfs) Co = orifice discharge coefficient g = gravitational acceleration = 32.2 ft/s Ao = effective area of the orifice (ftZ) Eo = greater of geometric center elevation of the orifice or d/s HGL (ft) h = water surface elevation (ft) Qo = 1.14 cfs outlet pipe dia = D = 15.0 in Invert elev. = 4992.17 ft Eo = 4992.35 ft h = 4996.73 ft - 100 yr WSEL . Co = 0.65 solve for effective area of orifice using the orifice equation Ao = 0.104 ftZ 15.0 in orifice dia. = d = 4.38 in Check orifice discharge coefficient using Figure 5-21 (Hydraulic Engineering) d / D = 0.29 kinematic viscosity, u = 1.22E-05 ft2/s Reynolds no. = Red = 4Q/(pdu) = 3.26E+05 Co = (K in figure) = 0.65 check Used= Aa = Q max Detention 4.40 in 0.106 ft' = 1.15 cfs 15.21 in 2 1 1 1 1 1 1 1 1 1 1 i Lincoln Center Emergency Overflow Spillway Sizing LOCATION: Lincoln Center PROJECT NO: 203-36 COMPUTATIONS BY: TDS SUBMITTED BY: North Star Design, Inc DATE: 11 / 18/2009 Equation for flow over weir Q = CLH3i2 where C = weir coefficient = 3.1 H = overflow height L = length of the weir top of berrn 4 F spill elevation p 100 yr WSEL Spillways will be designed with 0.50 It flow depth, thus H = 0.034 ft Size the spillway assuming that the pond outlet is completely clogged. North Detention & Water Quality Pond Q (100) = 6.50 cfs Spill elev = 4996.80 It 100 yr WSEL = 4996.80 ft Min top of berm elev.= 4996.83 ft Act. Top of berm elev.= 4996.83 Weir length required: L = 330.0 ft Use L = 330.0 ft v = 0.49 ft/s Detention e Design Procedure Form: Grass Buffer (GB) 1 1 1 t 1 Designer: Company: Date: Project: Location: Troy Spraker North Star Design, Inc. January 14, 2010 Lincoln Center Additions and Renovations Basin 1 1. 2-Year Design Discharge (Total) Q2 = 0.1 ds 2. Tributary Catchment Flow A) Minimum Width (Normal to runoff Flow path): Lp = Q2 / 0.05 LG= -➢Meet B) Tributary Area in Square Feet (A,) A,= 2.567 square feet 3. Design Width Along Direction of Flow (Use A or B) A) Sheet Flow Control Upstream i) Length of Flow Path Over Upstream Impervious Surface L, = feet ii) Design Width of Buffer: Wp = 0.2 * Li (10' minimum) Wo "^ ` 1 feet B) Concentrated (Non -Sheet) Flow Control Upstream (requires a level spreader in step 5 below) i) Length of Flow Level Spreader L, = feet ii) Design Width of Buffer: We = 0.15 * A / L, (10' minimum) We r.t feet 4. Design Slope (not to exceed 4%) S = % 5. Flow Distribution (Check the type used or describe "Other") Slotted Curbing Modular Block Porous Pavement Note: If Method B was Used In Step 3, #=Level Spreader Level Spreader Must Be Checked Here Other: 6. Vegetation (Check the type used or describe "Other") Irrigated Turf Grass Non -Irrigated Turf Grass Note: Irrigated Turf Grass Is Required in Semi -Arid Climates Other: 7. Outflow Collection (Check the type used or describe "Other") Grass Lined Swale Street Gutter Storm Sewer Inlet Underdrain Used Other: Notes: BMP_basin 1.xls, GB 1/14/2010, 5:30 PM Design_ Procedure Form: Grass:BUffer (GB), Designer: Company: Date: Project: Location: 1 tNotes: ' BMP_basin 2.xls, GB 1/15/2010, 9:21 AM Troy Spraker North Star Design, Inc. January 15, 2010 J Lincoln Center Additions and Renovations Basin 2 1. 2-Year Design Discharge (Total) Q2= 0.3 cfs 2. Tributary Catchment Flow A) Minimum Width (Normal to runoff flow path): Lo = Q210.05 Lc = 5" ,.;J feet B) Tributary Area in Square Feet (A,) A,= 4,355 square feet 3. Design Width Along Direction of Flow (Use A or B) A)Sheet Flow Control Upstream i) Length of Flow Path Over Upstream Impervious Surface Li = feet ii) Design Width of Buffer: Wo = 0.2 " Li (10' minimum) Wo : feet B) Concentrated (Non -Sheet) Flow Control Upstream (requires a level spreader in step 5 below) i) Length of Flow Level Spreader L, feet ii) Design Width of Buffer: Wo = 0.15' A,/, Lt (10' minimum) Wo ::feet 4. Design Slope (not to exceed 4%) S = % 5. Flow Distribution (Check the type used or describe "Other") Slotted Curbing Modular Block Porous Pavement Note: If Method B was Used In Step 3, Level Spreader Level Spreader Must Be Checked Here Other: 6. Vegetation (Check the type used or describe "Other") Irrigated Turf Grass Non -Irrigated Turf Grass Note: Irrigated Turf Grass Is Required in Semi -Arid Climates Other: 7. Outflow Collection (Check the type used or describe "Other") Grass Lined Swale Street Gutter Storm Sewer Inlet Underdrain Used Other: 1 1 1 1 1 1 1 1 1 f 1 1 1 1 1 f 1 Design Procedure Form Grass Buffer (GB) Designer: Troy Spraker Company: North Star Design, Inc. Date: January 15, 2010 Project: Lincoln Center Additions and Renovations Location: Basin 3 1. 2-Year Design Discharge (Total) QZ = 0.2 cfs 2. Tributary Catchment Flow A) Minimum Width (Normal to runoff Flow path): Lo = Q2 10.05 Lo = -,c`€ 4:.` feet B) Tributary Area in Square Feet (A,) A,= 7,900 square feet 3. Design Width Along Direction of Flow (Use A or B) A) Sheet Flow Control Upstream i) Length of Flow Path Over Upstream Impervious Surface Li = feet ii) Design Width of Buffer: Wo = 0.2' Li (10' minimum) Wp = feet B) Concentrated (Non -Sheet) Flow Control Upstream (requires a level spreader in step 5 below) i) Length of Flow Level Spreader L, = feet ii) Design Width of Buffer: Wo = 0.15' A,/ L, (10' minimum) We 4. Design Slope (not to exceed 4%) S = % 5. Flow Distribution (Check the type used or describe "Other') Slotted Curbing Modular Block Porous Pavement Note: If Method B was Used In Step 3, :: : %,? Level Spreader Level Spreader Must Be Checked Here Other: 6. Vegetation (Check the type used or describe "Other') Irrigated Turf Grass Non -Irrigated Turf Grass Note: Irrigated Turf Grass Is Required in Semi -Arid Climates Other: 7. Outflow Collection (Check the type used or describe "Other') Grass Lined Swale Street Gutter Storm Sewer Inlet Underdrain Used Other: BMP_basin 3.xls, GB 1/15/2010, 9:23 AM Design Procedure Form Grass Buffer (GB) Designer: Troy Spraker Company: Date: North Star Design, Inc. January 15, 2010 Project: Lincoln Center Additions and Renovations Location: Basin 4 1. 2-Year Design Discharge (Total) 02 = 0.6 cfs 2. Tributary Catchment Flow A) Minimum Width (Normal to runoff Flow path): Lo = Q2l 0.05 LG = F W ;12a ``? feet B) Tributary Area in Square Feet (A,) A,= 16,600 square feet 3. Design Width Along Direction of Flow (Use A or B) A) Sheet Flow Control Upstream i) Length of Flow Path Over Upstream Impervious Surface Li feet ii) Design Width of Buffer: Wo = 0.2' Li (10' minimum) Wo . tL, ;" o"; Ifeet B) Concentrated (Non -Sheet) Flow Control Upstream (requires a level spreader in step 5 below) i) Length of Flow Level Spreader Lt feet ii) Design Width of Buffer: We = 0.15' All Lt (10' minimum) Wo �,; , �,:=,Meet 4. Design Slope (not to exceed 4%) S = % 5. Flow Distribution (Check the type used or describe "Other") Slotted Curbing Modular Block Porous Pavement Note: If Method 8 was Used In Step 3, ;` Level Spreader Level Spreader Must Be Checked Here Other: 6. Vegetation (Check the type used or describe "Other") Irrigated Turf Grass Non -Irrigated Turf Grass Note: Irrigated Turf Grass Is Required in Semi -Arid Climates Other: 7. Outflow Collection (Check the type used or describe "Other") Grass Lined Swale Street Gutter Storm Sewer Inlet Underdrain Used Other: Notes: BMP_basin 4.xls, GB 1/15/2010, 9:26 AM Design Procedure Form' Grass Buffer (GB) 1 1 1 1 t 1 1 1 1 1 1 1 1 1 1 1 Designer: Troy Spraker Company: North Star Design, Inc. Date: January 15, 2010 Project: Lincoln Center Additions and Renovations Location: Basin 5 1. 2-Year Design Discharge (Total) QZ = 0.5 cfs 2. Tributary Catchment Flow A) Minimum Width (Normal to runoff Flow path): Lo = Qz / 0.05 Lo x "�9s a"feet B) Tributary Area in Square Feet (A,) A,= 16,595 square feet 3. Design Width Along Direction of Flow (Use A or B) A) Sheet Flow Control Upstream i) Length of Flow Path Over Upstream Impervious Surface Li = feet ii) Design Width of Buffer: We = 0.2 ' L (10' minimum) Wofeet B) Concentrated (Non -Sheet) Flow Control Upstream (requires a level spreader in step 5 below) i) Length of Flow Level Spreader L, feet ii) Design Width of Buffer: We = 0.15*Ail L, (10' minimum) We 'Mfeet 4. Design Slope (not to exceed 4%) S = % 5. Flow Distribution (Check the type used or describe "Other") Slotted Curbing Modular Block Porous Pavement Note: If Method B was Used In Step 3, Level Spreader Level Spreader Must Be Checked Here Other: 6. Vegetation (Check the type used or describe "Other") Irrigated Turf Grass Non -Irrigated Turf Grass Note: Irrigated Turf Grass Is Required in Semi -Arid Climates Other: T Outflow Collection (Check the type used or describe "Other') Grass Lined Swale Street Gutter Storm Sewer Inlet Underdrain Used Other: crate BMP_basin 5.xls, GB l 1/15/2010, 9:25 AM ..;Design Procedure Form: Grass ;Buffer (GB) 4 Designer: Troy Spraker Company: North Star Design, Inc. Date: January 15, 2010 Project: Lincoln Center Additions and Renovations Location: Basin 6 i 1. 2-Year Design Discharge (Total) Qz= 0.5 cfs 2. Tributary Catchment Flow A Minimum Width Normal to runoff Flow path): ( p ) Lo = Q2 / 0.05 Lo `.:R; eet B) Tributary Area in Square Feet (A,) A,= 15,314 square feet 3. Design Width Along Direction of Flow (Use A or B) A) Sheet Flow Control Upstream i) Length of Flow Path Over Upstream Impervious Surface Li = feet ii) Design Width of Buffer: Wo=0.2' Li (10' minimum) Wo = feet B) Concentrated (Non -Sheet) Flow Control Upstream (requires a level spreader in step 5 below) i) Length of Flow Level Spreader L, feet ii) Design Width of Buffer: Wo = 0.15 *Al L, (10' minimum) Wo feet 4. Design Slope (not to exceed 4%) S = % 5. Flow Distribution (Check the type used or describe "Other") Slotted Curbing Modular Block Porous Pavement Note: If Method B was Used In Step 3, ��..,;_,t; Level Spreader Level Spreader Must Be Checked Here Other: 6. Vegetation (Check the type used or describe "Other") Irrigated Turf Grass Non -Irrigated Turf Grass Note: Irrigated Turf Grass Is Required in Semi -Arid Climates Other: 7. Outflow Collection (Check the type used or describe "Other") Grass Lined Swale Street Gutter Storm Sewer Inlet Underdrain Used Other: Notes: BMP_basin 6.xls, GB 1 /15/2010, 9:27 AM I ' APPENDIX E ' FIGURES AND TABLES , I I I E 0 LU _GjO - 04 0 M.-MMUM .......... gg, "In "'o 11.14 j . �k,' 4'--p P, 1 g1tS 11 f g; co .Vvi rr wa il .2 (0 ;JAX D. "Mr Oil AR f% Rk 14 CLYr x2rrz9iq ERAVI .4x Ez 0 A:� (L 54 qq g T11 AMI _124 llffi ;YK C) O C 0 C) 0 0 CD 0 0 C) C> CD CD (D 0 C) C) C) CD CD C) C> CD o 6 06 ti 6 t6 .4 C15 N C; (j4/Ul) Aj!SU84uj City of Fort Collins Rainfall Intensity -Duration -Frequency Table for using the Rational Method (5 minutes - 30 minutes) Figure 3-1a Duration (minutes) 2-year Intensity in/hr i 0-year Intensity in/hr 100-year Intensity in/hr 5.00 2.85 4.87 9.95 6.00 2.67 4.56 9.31 7.00 2.52 4.31 8.80 8.00 2.40 4.10 8.38 9.00 2.30 3.93 8.03 10.00 2.21 3.78 7.72 11.00 2.13 3.63 7.42 12.00 2.05 3.50 7.16 13.00 1.98 3.39 6.92 14.00 1.92 3.29 6.71 15.00 1.87 3.19 6.52 16.00 1.81 3.08 6.30 17.00 1.75 2.99 6.10 18.00 1.70 2.90 5.92 19.00 1.65 2.82 5.75 20.00 1.61 2.74 5.60 21.00 1.56 2.67 5.46 22.00 1.53 2.61 5.32 23.00 1.49 2.55 5.20 24.00 1.46 2.49 5.09 25.00 1.43 2.44 4.98 26.00 1.40 2.39 4.87 27.00 1.37 2.34 4.78 28.00 1.34 2.29 4.69 29.00 1.32 2.25 4.60 30.00 1.30 2.21 4.52 1 City'of Fort Collins Rainfall Intensity -Duration -Frequency Table ' for using the Rational Method (31 minutes - 60 minutes) Figure 3-1b 1 1 1 1 1 1 Duration (minutes) 2-year Intensity in/hr) 10-year Intensity in/hr 100-year Intensity in/hr 31.00 1.27 2.16 4.42 32.00 1.24 2.12 4.33 33.00 1.22 2.08 4.24 34.00 1.19 2.04 4.16 35.00 1.17 2.00 4.08 36.00 1.15 1.96 4.01 37.00 1.13 1.93 3.93 38.00 1.11 1.89 3.87 39.00 1.09 1.86 3.80 40.00 1.07 1.83 3.74 41.00 1.05 1.80 3.68 42.00 1.04 1.77 3.62 43.00 1.02 1.74 3.56 44.00 1.01 1.72 3.51 45.00 0.99 1.69 3.46 46.00 0.98 1.67 3.41 47.00 0.96 1.64 3.36 48.00 0.95 1.62 3.31 49.00 0.94 1.60 3.27 50.00 0.92 1.58 3.23 51.00 0.91 1.56 3.18 52.00 0.90 1.54 3.14 53.00 0.89 1.52 3.10 54.00 0.88 1.50 3.07 55.00 0.87 1.48 3.03 56.00 0.86 1.47 2.99 57.00 0.85 1.45 2.96 58.00 0.84 1.43 2.92 59.00 0.83 1.42 2.89 60.00 0.82 1.40 2.86 1 I I .1 tJ 0 9 9 WIN-11 m FLOODPLAIN INFORMATION F TECHNICAL DOCUMENTATION for the BASELINE HYDRAULIC MODELING OF THE OLD TOWN BASIN PREPARED FOR: City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 PREPARED BY. Anderson Consulting Engineers, Inc. 772 Whalers Way, Suite 200 Fort Collins, CO 80525 (ACE Project No. C0FC14.1) July 15, 2003 I 1 I 11 11 0 � 3 �yo�P ST : �- 12 p LL0479' MOUNTAIN AVENUEMAP SCALE 1" = 500' '. 50 0 500 1000 FEET Asx- ETE LU n 4CA onnM w z � y •:::::t:i::: ZONE X 9� iI Q Q 1-U) m - F OAK STREET OAK STREET 0 0 LL0480 g+ = n LL1029X ZONE o ��� 3 w O P = w I 1 C� ac ie La POudre River , WARNINGI THIS AREA IS SHOWN AS BEING PROTjECTED FF OM THE 1 PERCENT ANNUAL -CHANCE FCOOU HAZARD' BY- CEVEE, DIKE, OR OTHER STRUCTURE. OVERTOPPING OR] FAILURE OF THIS'STRUCTURE IS POSSIBLE, WHICH COULD RESULT IN DESTRUCTIVE F FOOD ELVATIONS AND HIGH VELOCITY FLOOD�WATERB.� THERE IS A CHANCE THAjT LARGE FLOODS WILL OCCUR THAT ARE GREATENTHAN THEELEVEL OF PROTECTION PROIVIDED BY THE LEVEE. CONIMUNITIEG SHOULD ISSUE EVACUATION PLANS AND ENCOURAGE PROPERTY ZI WNERS BEHIND HESE STRUCTURESi6 UR'CRAS FCd061NSURANCEEVE41FTHOSTRUC-TURE-IS-CURRENTLYSHOWN A w 7t=: THE 1 PERCENT -ANNUAL -CH NCE FLOOD. STREET--�—_-z� w z � Wz y > Q w y w ¢ Q � rn MYRTLE STREET r w O Im 3 w w w 21 LAUREL STREET 2 LL0485X o 0 o W ZONE X u ZONE X z N m m r P AREA SHOWN ON THIS PANEL IS w w llllp�llmillliflll�. PANEL 0979G FIRM m FLOOD INSURANCE RATE MAP ®' LARIMER COUNTY, m COLORADO ml AND INCORPORATED AREAS I PANEL 979 OF 1420 a (SEE MAP INDEX FOR FIRM PANEL LAYOUT) m CONTAINS: COMMUNITY NUMBER PANEL SUFFIXNt LIMER COUNiv awioi W79 G FORT Ccialm. CRY pF 101 09 Mon G I m I NmlLa m Uear. Tbe MOP Number shown balmy Shined be used when p edw ou"' immune: th e: e Community Number Mown above Ohni be used on msunns applt�vu nor me subjem dw m�ty. mm MAP NUMBER T 08069CO979G MAP REVISED JUNE 17, 2008 Federal Emergency D1anagement Agency LOCATED OLD tY MAIN DRIVE y HIN TOWNSHIP 69 WEST, RANGE 7 NORTH. m PLUM STREET z STREET w 0 w w Q a w TILOCUST LL0483 xr ISOTOPE �RfVE I STREET DRIVE > LL0516x w r o m This is an official copy of a portion of the anon referenced flood map. It r 1 inras extracted using F-MIT On -Line. This map does not reflect changes Wor amendments which may ha a been made subsequent to the date on the 3 ELIZABETH STREET title Program dock. For the latest product information about National Flood Insurance flood maps check the FEMA Flood Map Store at www.msc.fema.gov WHAT ARE THE PROBLEMS? a m M�Wj PXMC7 RY ST 750 1.500 CA r rn I I I I I I I I I I I rr LD T(OYW- CANAL I MPORTAWN BASIN gq AIL CREEK AS1 N zors I 4 BD w c I wM r W 1fAR w41 PEISMARD -.. I 4B6.J] r UICERCNAMY WI INI71111,A' 100 WSR MAGNOLIA STREET R9H 73 Aosw.ME wM LINWPMFmRuu Mel p� `(� r ICU rEAA rsFL y / NN.A add APPROl ♦ IT I I L eE,ac�EunT�xE All Z HIGH RISK m� � r 901WN AND We don" �7 Fly Fly 0.lo 0.Fly, ♦�, E U L\ e D.x 0.4 J lrmmmmmmmmmm__.�________________________ 41, Alan 41, EXISTING BUILDWG ♦ \ \, ly f : '•All K" � , ♦, Fly W, Mel —-----,. _ — 'Al♦d a w ,� 4 I ExIBTrq eu.oNCB I I �I Ij I � u m 0+ ; 00 E 100 YEAR I FLOOOPLAIN r f "WAY CALL UTDTY NOTBICATION CENTER OF COLCRADO 1b800b922b1987 LDL z-BUSNESS DAYS IN ADVANCE B6 YW PG. MACE. M ERCAVAIE FM ME AMONG BE UNDERGROUND MEMBER UnunES. DPEcnME♦. 1.03 0.J HM RUN PLOLLVI.VI BQIDAR. IEEE SOMDMY —(TYPE \ Sol n USERS ASPHALT PARKING rT 0000 c E 00 15 0 30 60 SCAUE. 1' _ 30, Q3 OESHGN PANT — — — — USING PIPES AREA PRCVO9E0 siM PIPE BLA IN a90s m 0. s m Ruxgr comlgMT o R.Mm MD YcnM EMISITHO 5' CONTOUR FLOW OIflECPW EMISPHG Y Cg1iWx BASIN B WARY —"I— MWO S CMTWR EllIEXCE INWOSED 1' C TWR —SF—SF— Mel (RED, wATTW ® CONSMUCTION ENTRANCE Op 0 INI£T PROTEIN s MDA ER AND SEq T CM1 M C ST MW PLAN NOTES At °� emote w ny mmw 01 u• m� col �w�� a. m.4w,kn Ru u I .[vv.w 4 At,tiH n . v4 0.ra� �r.wl rn b n.nllne And m "lm cl ms n N . q nu.a W s u mnnH. L Had o..Nw Melt au w A AAA, A, weal em "NOWEAF; dhadown �.mlm thea«-�LI I im�I�nImWM W obmxe� yv achy A DOW i...wt mHA�wm Men w TIDIER +n,<x. EMI w I�mnm m .. ut y�.r w,ng t.0 aw "x tw Ovtwbq. P. AWAY wn l'te nuyuµ fli 111)1 be At t. a mq,we * contrafter If ��y dean A Any dial abler .1. AFAM'Itly Moody bad of A dog Maday A Uganda. Y Mae POAI G obbi ral MeA Ad ga. ol And mul�W f. ail1ol n wm OW an Andy, real v.,rm and" 1wlem..e bad uinmm ., In m...., ...no..o.d...mat ,. WE My WA W Of to FIT Medical ,..,te . e...enm.am.m, on. n F and gotFA 1 1 Po..wonl... Way manwe�uihe w Wd R. ¢ A s h. by to:.O.e. oAll Iru n wmt a Hy Lon to Own ,o 0 Cate, If AMOR, d man �unt - __ Way nlwmin� nay n. ,Irma by L. C'tY al �n.w BASIN SUMMARY TABLE BASIN DE4M PANT AREA GO TO, Bob ON, I 1 MASS 0.M SO at a] ] 9 BID ON '+D a 3 : GAS O.0 5.0 aa: am 0.57 &A, I TI z] s 5 am aD No 1.0 v 9 e am 0.Y S0 1.0 21 FAST AS aD v ze EEEVATM SUMMMY TABLE EM SOUTHEAST ACNTM BASE aOAD ELEVATION K 7.1 LUMLhI ROM Ll VATM 411 uwt MUM xvLc E1LMnM N9].e HELIUM Mae (MO) K9SW DETENTION POND SUMMARY TABLE I00-n1 1�]n IDIFA4 now utxtuux DEIpnM AGE pATE CMIR0. eAllx VOLUME MI EILv.LnM 53" AM N 73 1.11 al .AO In A99SM5 NOTES 1 ALL TEMPORARY AND PERMANENT ERDSM AND SEDIMENTASON1nQ PRACTICES SHALL BE MAINTAINED AND REPAIR O DURING THE C Sp UCnnM PHASE NEEDED TO ASSURE CONTINUED PERFORMANCE N THEIR INTENDED NNCn W. ES PERIODIC RE LLLL¢YENT AND ALL "MT ACCUMULATED BEHIND M MUST BE MO1CO AND DIYOSED OF PROPERLY. TES MUST BE INSPECTED BY ME OR COWERS REPRE4HTAOVE FOLLOWING EACH HEAVY PRECIPITATOR OR GROW FELT EVENT THAT RESULTS IN Moody Y LDG IN OF GUY OF EMT COLONS HIM AND INCARNATE MAN 1M WEAR PROJECT TO PLACE IILL IN TM THISSAPPROVED FLOOD rMNW l0 M5°Yflaf THE FLPLAIANPBOl1 AND ME PILL Is IN PLACE, M MN OM Is ao LUN HOWE,RM. THE IIMNO wu REMAIN MR Al RISK RL PUIN. DURING A 1M TEAM Sn M MERE IS A.Aa MOOEGY SELL CHANCE THE BUILDING MAY11FL S. ME BAY FLOOD ELEVATOR OF YET BUIWING IS 49990 R-Ralf THE REGULATORY FLOYD PROTECTION ELEVATION IS 49N 5 PT-11i FOR ANY NEW ADDITIONS THAT ME CONSTRUCTED ON STRUCTURES LOCATED MMw THE HIM RISK FLOW BOUNDARY. A ME OMESHAALLL OMAIN A FLOWPUIN U„ PMMT FOR ALL STRUCTURES AND SIZE WORA WITHINE Np K. SGEWALKS, CURB A, GUTTER , SCARING INCLUDDES10S6 PRIOR TO CONMTUCIIMED MO�ANIY OTTER BY CHAPTER CITY EERO IS IA100 YEAR UESONAToRWTILOCATED SIT WORK. WIIMW City of Fort Collins. Colorado CMSMUCTM. MD OTHER DEL4LMMERT MUST UTILITY PLAN APPROVAL MEET THE REQUIREMENTS M CHAPTER 10 M THE CITY CODE. APPROVED: IN O E A LOON REPORT AND LOUR FOR ADgnp1AL q1r En9ln.e, Dab u nM CH O ME HIM MA TO THE PRyOY.D STE TO HE CHECKED BY: IMPROVEMENTS Waiv s W ti tw GORE Dab $ Dl CS3 ECT EN. M YCDM �i A PEE FOUNDATOR (F - M MOSS SECTON. CHECKED BY: slmm.al� Vt11lY aab B. IMMEDIATELY UPON CgRLETM DIY LET PROPOSED IMPROVEMENTS NEAR THE SWIHUST CHECKED BY: PR SH LL BE COMPLETED ASBUILT SUTHE vw s RICE mI Wb EVEY OR ME I WMM3SHALL OR -THE TO REMOVE EiisHrvG BUILDING AND CHECKED BY: PROPOYO AUCTION FROM THE HIM RISK P91,M W W PRIM TO BEPNNING CONSTRUCTOR ONnallle BE ME PROPOSED ADDITION. CHECKED BY: Wb Z L_0 Q 0 0 NZ O Al O 08 U N Z Z Z J � 0 ° U Otweed O 0:Q LL O Q O Q a/ F J U z V Z read J V J LLER•LINGLE•MASSE AaCHITECT P.0 MAIM>, P�mDimluWS Norfh .Star ',_tlesgn,inC DRAINAGE & EROSION CONTROL PUN 011 An mry9/M >�eR C400