HomeMy WebLinkAboutDrainage Reports - 01/24/2016❑QUALITY `X ENGINEERING WWW.QUALITY-ENGINEERING.COM Lo4{ (o, 2-1k 1(o(o, FTC January 25, 2016 -2, ( �'; 0$ 245,1 'l3 i S O'E 2.l Mr. Shane Boyle & Mr. Dan Mogen City of Fort Collins Engineering Department 281 N College Avenue Fort Collins, Colorado 80524 RE: Drainage Memo,— 625 Smith Street 625 Smith Street, Fort Collins (Larimer County), Colorado 80525 QE Project No. 6278-01 Mr. Boyle & Mr. Mogen: The purpose of this letter is to address drainage impacts to the existing 0.22-acre property located at 625 Smith Street due to the proposed building and garage. The site is situated in Lot 6, Block 166, City of Fort Collins, County of Larimer, State of Colorado. Specifically, the property is located midway between East Myrtle Street nd Laurel Street and bound by Smith Street to the east an a common alley access -way to the west. Thi subject property is surrounded by residential properties t6 the north, south, across the alley to west, as well as across Smith Street to the east. (See Vicinity Map) The existing property currently consists of a house, shed, and mature landscaping. The existing site has a local high -point splitting lot flows to the east and west. Approximately 3/4 of the existing site drains to the east, toward Smith Street. The remaining drainage, located west of the local high -point, flows west to the common alley, historically. The existing structures and site features shall be completely demolished for the proposed house and garage construction. The proposed improvements include a single family home with basement comprising of approximately 1,900 sf footprint, along with porch and deck areas. A +/- 600 sf garage with attached car -port is also proposed to sit at the west end of the lot, adjacent to the common alley. The site percent impervious went from 6.0% (existing) to 45.4% (proposed). Drainage swales are proposed along the north and south edges of the property to help mitigate developed runoff and keep consistency with historical flow patterns. No on -site detention is proposed for this development. Water quality shall be achieved through said proposed drainage swales with natural flowlines. The developed flows from the east basin shall sheet flow into proposed drainage swale flowlines where runoff will continue to be conveyed east. The proposed drainage swales along the north and south property lines shall extend from the Smith Street ROW west all the way to the existing alley. Developed flows from the north side of the property shall sheet flow into the northern swale and be discharged at the east end of the property, as they do historically. Developed flows from the south side of the property QUALITY ENGINEERING, LLC (970) 416-7891 2637 MIDPOINT DRIVE, SUITE E FORT COLLINS, COLORADO I12-a/ ((p Page 2 shall sheet flow into the southern swale and be discharged at the east end of the property, as they do historically. Drainage calculations are provided for this project due to the increase of impervious area on the exiting subject lot and to verify that increased flows will not adversely impact adjacent properties. The City of Fort Collins Stormwater manual amending the Urban Storm Drainage and Flood Control District (USDFCD) has been used for drainage design guidance. Please see the attached hydrologic basin parameters, 2-year and 100-year existing & developed flow rates. In summary, the grading and drainage design for the proposed home and garage at 625 Smith Street complies with the requirements of Urban Storm Drainage and Flood Control District as well as the City of Fort Collins' Storm Drainage Criteria. The proposed changes have nearly negligible effects on the historic drainage system of the lot. Please see the attached grading plan and drainage plan. If you have any questions or require additional information, please call at (970) 416-7891. Sincerely, QUALITY ENGINEERING, LLC A,L WOE Mark Morrison, EI Project Manager Attachments — Reviewed by, Cody Geisendorfer, PE, CEM Principal 1 ngineer Appendix A -Vicinity Map -Existing and Proposed composite `C' values -Existing and Proposed flows (cfs) -Grading/Drainage Plan 04 Else 00 0 41326 m S COLLEGE AVE REMINGTON ST m m m m m C U m r m D C o (� m m m m 07 m = —Ni r- Ln m 0 - - ALLEY SMITH ST E STOVER ST Z � � \ V L a �c S LEMAY AVE HAMMERSMITH STRUCTURES QUAUY 825 SMITH STREET ■ !� W IMERM FORT COLLINS, COLORADO $0524 1501 A ADEW CpxR, /tot 106i VICINITY MAP p (� i�� WOUMCOM 0 CU fC V a1 N 0 a E 0 U u X _ Y O U m lD O lD ci N O Lr1 i O O O —1 O O 'N fp O Q E O v � u Ln ci Ln Ln ci N C1 lcz� p p_ O O 0 0 C E O V Q v m o m ci 'T O 00 0 u O O O O F- d u O n ^ O N 9 N O O O � ci H p II O CD O 3 `. J N d V � O O ct O m O 00 0 H U o 0 0 0 0 O ` a bO c - w a o X > O LLJ O CD O O O O O O O 0) II > U O O O O a ru Ln 0 ko rn o 0 0 0 0 Q` y O O O O � U `u c O V v V m U1 d 0 O O O O O O O O Q II a-i O O O O M t Q Q N C ci N ci N W W co p] m co c O c NO a p p 0) O 0 N DD N c-I L c H C O Ln u N m u 3 E o cn LL Ln N lD m co > 0 o m m o 'C o c m � o 0 O o n m N .Ni 0 ti° 0 0 m of m N 0 M 0 N O 0 c C W C T p o om �ti m ai N N C_ F o D 0 F C O � ul ui ~ a0 n o m i" O O O O1 l0 M N C O O O N n n p a m m v, ca E_ � c m m F a s a s m F L U a+ 0 N N a yO ✓1 0 O o H "•' 0 N l0 .y d o $ c w O o s o 7 E N w O N a E mC a N C C E o0 N O n � O N e 1p \_ — a N m m EO c N o 0 O 0 0 ti u a G E V N Y1 V a a E 0 u 0 0 ti 0 .ni 0 m c m C •d N a o 0 0 SECTION A -A NTS EXISTING GROUND PROPOSED GA RAGE SECTION B-B NTS �1" ) L )PERTY UNE (TYP) SECTION C-C NTS TOF"4664.32' POSED HOUSE W DRAINAGE LEGEND 8 BASIN NAME BS PERCENT IMPERVIOUS AREA IMP ���� AREA (ACRES) D1 DESIGN POINT BASIN BOUNDARY PROPOSED FLOW DIRECTION A A DRAINAGE SECTION BASIN AREA(ACRES) COMPOSITEC %IMPERVIOUS lODYR FLOW(CFS) 81 0.04 LOD 96.7 0139 2028 O56 34 L00 E2 003 0.19 0 004 E2 0.19 0.26 6.9 0.32 NOTE: DROP BOTTOM OF FOUNDATION (2'-4" MAX) TO MAINTAIN FROST DEPTH AT FG SHOWN 2 W J a C4 WO I� D: U Lu U1 ? PROPERTY LIME x z? � �o c y U LL o 0 Z r^ c LL C 2 V '/ARIES �0 11CF (NOT TO EXCEED- �Q� OEIg NH+1�10ErcE�A�1 47326 O^ L ElU6TING GROIlO PROPOSED GROUND ��� R PEMR RAN CHECKED BY: GG DESIGNED W: MHM DRAWN W. MHM 20' GM' JANUAR(. 2016 SG E : 110 SCALE: 1" = 10' PROJECT NO.: 5276-001 C1.0