HomeMy WebLinkAboutLot Certifications - 08/27/1996 (7)August 19, 1996
Basil Hamdan
City of Fort Collins
Stormwater Utility
235 Mathews
Fort Collins, CO. 80522
RE: Drainage Certification
Lot 28 of Stetson Creek First Filing P.U.D.
Project Number: sec; 961 o.oo
Dear Basil:
NORTHERN
ENGINEERING
SERVICES INC
We have completed our review of the as-bu ilt grading for the above referenced
lot. According to the Development Agreement for Stetson Creek P.U.D. First Filing,
Lots 5 through 16, 21 through 23 and 28 through 30 require certification from a
licensed professional engineer that the lowest opening to the house is a minimum of
one (1) foot above the maximum water surface elevation in McClellands Drainageway.
The most recent HEC-2 model for McClellands Drainageway was obtained from
RBD, Inc. on March 20, 1996. The calculated water surface elevations from this
model wi ll be used as the basis for determining compliance with the criteria set forth in
the development agreement.
Lot 28 is adjacent to the McClellands Drainageway. Based on field survey
information, shown on the enclosed plan, finished grades and minimum opening
elevations are well above the calculated water surface elevation of 4928.10 in
McClellands Drainageway.
To the best of my knowledge, belief, and opinion, the finished grading on Lot 28
is in substantial compliance with the design intent of the approved construction
drawings and with the development agreement. If you require additional information
or analysis regarding this project please contact me at 221-41 58.
Sincerely,
NORTHERN ENGINEERING SERVICES, INC.
Mary B. Wohnrade, P.E.
cc: Dennis, Geneva Homes
420 SOUTH HOWES, SUITE 202 , FORT COLLINS, COLORADO 80521 , (970) 221-4158 , FAX (970) 221 -4159
/
- ---- - ---- -