Loading...
HomeMy WebLinkAboutSite Certifications - 01/05/2015C O - I /mot/ /19 1 COMMERCIAL, MULTI -FAMILY AND SUBDIVISION CERTIFICATION FORM & CHECKLIST (Overall Site Drainage) Cargill Office Expansion (Project Name) 1 /5/15 (Date) of 11�_�� 24 ro 'E lJr+ Z.0,4 � Rt4-04$(02 (For Commercial or Multi -family, please list any applicable building permit numbers) Please fill in all applicable Items in this Certification Form for Commercial, Multi -Family and Overall Single Family sites. A copy of the approved grading plan must be submitted with the as -built grading plan. (It is preferred to have the as -built elevations written in red next to the approved elevations) Use "OK" for items checked or actual numbers for items verified/surveyed in the field. Use "N/A" for Items that are not applicable to the site that is being certified. Please provide an As -Built Redlined or Mylar drawing showing the following: A. Detention, Drainage Facilities, and Common Open Spaces 1. Pond Certification OK Provide Topographic Records (grading certification with as —built spot elevations) and Volume Verification Calculations. Show both the proposed and as -built elevations on the same plan sheet. OK — Provide Pond Cross -Sections and Spot Elevations (especially @ Pond Embankment and Pond Flow Line) OK — Positive Fall to Pan (if applicable) OK General Pond Grading including all Side -Slopes oK Invert Elevation N/A Forebay Construction and Elevation OK Spillway Weir (Location, Elevation, Height, Opening Width) OK Placement and size of riprap or alternative permanent erosion control measures OK Orifice Plate and/or Water Quality Outlet Structure Installation OK Water Quality Capture Volume (Volume Required, Volume Provided and Water Surface Elevation) — Berm and Embankment Compaction Level N/A Subsurface Media for Water Quality Ponds and Swales 12/ 12/2014 Revision — Page I of 5 2. Swales N/A Location (are they within easement?) Dimension and Cross -Section Verification Longitudinal Slopes and Side -Slopes — Spot Elevations — Permanent Erosion Control Measures (drop structures, riprap, lining) — Tie-in to Storm Lines, Pans, Curbs, or other appurtenances — Required Minimum Freeboard, Provided Freeboard — Landscaping Infringement on Flow Line? 3. Pioes OK Size and Type OK — Slopes (As -Built and comparison to 0.4% Minimum) N/A — Pipe Capacity Calculations (if slopes are significantly altered from design) OK Invert Elevations — Installation and Backf Ill — Cover — Encasement and Clearance from other nearby utility lines — Joints Type and construction 4. Concrete Pan Channels OK Size OK Slope OK Cross Section — Thickness OK Elevations City ofFortColh 12/12/2014 Revision — Page 2 of 5 — Headwalls or Wing Walls S. Sub -Drains OK — Size OK Type(Perforated/Solid) — Cover — Backfill of Fort`` 12/12/2014 Revision — Page 3 of 5 FOB Nof HS — Geo-Textile Liners — Clean -Outs 9. Curb Cuts OK Size — Tie-in to Swale, Pipe or other appurtenances 10. Common Open Spaces N/A — Overall grading contours of open spaces — Spot elevations adjacent to private lots (property corners) B. Low Impact Development (LID) Certification 1. LID Technique Specific Checklists (see attached) — Permeable Interlocking Concrete Pavers (complete if technique utilized on site) — Bioretention Cells (complete If technique utilized on site) Implemented Grass Buffers and underpavement runoff filtration only. C. Grading Certification 1. Certification of Grade Elevations OK Minimum Opening Elevations OK Top of Foundation Elevations OK Comparison to 100-year Water Service Elevations OK Comparison to Freeboard Elevations 8Rd Base Fleedplain 2. Verification of Site Grading OK Engineer to evaluate site grading compliance with the approved grading plan. OK As -built elevations are to be redlined onto the approved grading plan sheet showing the as -built spot elevations next to the design spot elevations so compliance can be verified and documented. 12/ 122014 Revision — Page 4 of 5 M Fort Collins D. Post -Construction Site Cleanup I. Permanent BMP Measures OK Construction Debris Clean -Up (In particular debris affecting the drainage) OK — Smoothing of Ruts in all Construction Areas OK Reseeding of all Areas Affected by Construction Activities (Usually enforced by the City's Erosion Control Inspector but the engineer certifying the site needs to notify the contractor if areas are not seeded) E. Statement of Compliance reviewed This certification is signed and stamped and by signing this form the Engineer(s) attests that they have -iRsyected the site and to the best of their knowledge the as -built conditions of the drainage facilities areas described in the above form and in the As -Built plans enclosed. Failure to properly disclose all known information could result in the rejection of this certification and prevent the release of any and all Stormwater Utility permit holds on Building Permits and/or Certificates of Occupancy within this development. F. Signature and Stamp by a Colorado Registered Professional Engineer Engineer's contact information: Patricia Kroetch (Name) tricia@northstardesigninc.com (Email address) 970-686-6939 (Telephone number) North Star Design, Inc (Company Name) 700 Automation Drive, Unit I, Windsor (Company Address) PE STAMP - 12/12/2014 Revision - Page 5 of 5 H C Gl _ L • a C O a d u C 0 v = � eo z 3 d b+ta of as a� U W y 01 d A �o C 'C C � C o y Ca ttt 4�r a� cc C Cd cf°.� M cis .cO 0 s w � rn c6 N O y a+ C c 3tg cC a Ia UrA O O CL � c\I�_„ •y. O F. Q '� y ,,,,0 N ��j N tf .�.� cC O� ^� � o ° a�i aXi 3 o o§ a M^ .vf° 0 � ° � = °�' CL ca s p., � +•+ O ,, a+ .5 ue 0 U 0 L' Ir Ir L. 0 OE r4 0 w O= y •} C in G C C C U cC .0 N N 0 1.+ .O • ,'�., 0 o:3 o`0 w coa of)Ga rsS w° a O o b 3 0 K y❑ ry H 1 1 1 w s cz ,b0 C m 0 E¢ ° a v �¢UU of) No Text _C U O U 2 T A O O 0 a o 0 a o 0 d LIU 0 G ° 7 ❑ > N u O _ b b W � b c 3 b p o 0 CCL CL t C. e, a ca ce c w— O ° ca o O O O ❑ca 0 z C `" z v c ai � 6 u a> i x w L y d O 7 p O 3 Y O o o 0 p 0.2 y C co U O i x v° � 2 w 0 o ae cj ° N p b ..., N C 'C� .° N U U U co E M O O N cpo U Itj OJ 'fl y C rA O Q C • rA Zr O. i N N VfO. 3 cYUo C a��+ N N N " V y O .O G w w b C ro- U cam o ❑ CL >, E E o a� C C y o 0 0 o b b 3 > c O ° '� b .y.. a� 0 0 o ° o 0 o o° o °' a x ommw 5 L w°k°. O il �QUUO�� y r> co C acl iE ° o Y Q ~ CA 'z .�. w c d 0 � � O +�+ v C U i a w d � o as ° wy C E C U F" p b ❑ N O ti p y o E -a°; o Ln c C � o " `° 3 C 3 p °°' •°° o Y O� 0 3• co C n N b N D N °°' a •° a �' " °Y' E E E C c03 •O U •'�•• �O" coO o N ._ cC to a0i ; E a 0 wtwWae a� ,m xa wdo y bfb99bi01! �Iald t°N1°�°'�W �I�boe bdd xa wWaa NVId JNI0tlN9 = e -alq' xe-.I '+ws '1 NOI$NddX3 d /O7$ i ll0^I nra xe li]db <,I 30wo mmuvo e 4 6 m I 9 _ d o p 1 ill 1 a ! l � , 8 \ I , ' b I t :1 t t t ` t I d , 1 \ t l , 't t t , , 1 t - --Ildlill 3� No Text No Text No Text ..\ ` .. •- .. ..� -�. 1 ��, • � • . �; l • i. l . t 1 � 1 ` ` 4 STAGE - STORAGE TABLE 100-YEAR LOCATION: Cargill office PROJECT NO: 347-02 COMPUTATIONS BY: PPK DATE: 1/21/2015 DESIGN ASBUILT Extended Water Quality Volume Required = 0.022 100 yr Detention Volume Required = 0.131 0.152 POND 1 (east pond) WQCV 100yr WSEL Stage (ft) Surface Area W) Incremental Storage (ac-ft) Total Storage (ac-ft) 4922 0 4923 0 0.000 0.000 4924 932 0.007 0.007 4924.4 2,202 0.015 0.022 4925 3,945 0.053 0.060 4925.6 9,367 0.092 0.152 4926 12,515 0.176 0.236 4926.5 18,141 0.175 0.411 POND 1 (east pond) WQCV 100yr WSEL Stage (ft) Surface Area (ft`) Incremental Storage (ac-ft) Total Storage . (ac-ft) 4921.82 0 4923 122 0.001 0.001 4924 1 738 0.009 0.010 4924.4 1,961 0.012 0.022 4925 3,856 0.049 0.059 4925.7 8,907 0.093 0.152 4926 11,472 0.165 0.224 4926.5 18,141 0.168 0.392 r 1.315 0.224 Extended Water Quality Volume Required = 0.097 100 yr Detention Volume Required = 0.910 1.006 DESIGN POND 2 (west pond) WQCV 100 YR WSEL Stage (ft) Surface Area (ft`) Incremental Storage (ac-ft) Total Storage (ac-ft) 4922 0 4923 4,347 0.033 0.033 4923.46 7,869 0.064 0.097 4924 11,937 0.180 0.213 4925 17,680 0.338 0.551 4925.89 27,519 0.458 1.009 4926 28,735 0.528 1.078 4926.5 26,000 0.314 1.392 ASBUILT POND 2 (west pond) WQCV 100 YR WSEL Stage (ft) Surface Area M) Incremental Storage (ac-ft) Total Storage (ac-ft) 4922 0 4923 6,952 0.053 0.053 4923.46 10,683 0.093 0.146 4924 14,994 0.246 0.299 4925 22,693 0.430 0.729 4925.89 26,065 0.498 1.227 4926 26,482 0.564 1.293 4926.5 26,000 1 0.301 1.594 Wes Lamarque From: Dave Stringer <dstringer@dohnconstruction.com> Sent: Thursday, January 22, 2015 6:38 AM To: Wes Lamarque Cc: tricia@northstardesigninc.com;jrehmer@dohnconstruction.com Subject: FW: Cargill Office Expansion Drainage Certification Good Morning Wes, Regarding your list for Tricia below, I am responding to her comments to me. #2 as we discussed was installed per owners request without consulting the engineer. The storm drains and related green houses were not part of this project. At the owners request, we installed a swale to capture the water from the field and get it to pond 2. Along with that we added a culvert to allow field access, also per owner request and without consulting the engineer. The green houses and related drainage will be installed in the future, once final site —configuratio n_is completed_and_projects_are_under.construction. The swale and culvert will be removed with these future projects. Numbers 3 and 4 photos were forwarded to you last Friday. As noted in her email, Tricia should have gotten her documentation to you last night. Let me know if you need anything else. Dave Stringer, LEED AP Quality Assurance Manager Dohn Construction, Inc. 970-490-1855 (CO) 307-634-6177 (WY) 970-490-6093 fax 970-566-0260 Cell dstringer@dohnconstruction.com Please consider the environment before printing my email From: Patricia rmailto:tricia(cbnorthstardesicininc.com] Sent: Wednesday, January 21, 2015 8:22 AM To: dstringer(cbdohnconstruction.com Subject: FW: Cargill Office Expansion Drainage Certification I can take care of #1. 1 don't know what he is talking about in #2, 1 don't have photos for #3 and #4 is for you. I won't be able to get to it until late today — even if Steve calls, I still won't get to it until late today. Tricia From: Wes Lamarque fmailto:WLAMARQUE@fcgov.com] Sent: Friday, January 16, 2015 2:16 PM To: tricia@northstardesigninc.com Subject: Cargill Office Expansion Drainage Certification Hi Tricia, I walked the site yesterday and most everything looks good. I have a couple items we need to document in the certification. 1 1. Please provide pond stage -storage curves to verify quantity and WQ volumes for all the detention ponds. 2. Please document the temporary swale and culvert and how it will be removed when phase 2 is constructed. . 3. Please provide pictures of the underground LID system that was taken during construction. 4. Please document that the all riprap needs to be buried. The riprap located in the northwest forbay is not currently buried. This needs to be completed in the spring. I'm checking to see if we can include this with Jesse's erosion escrow. I know the owner wants their CO next week, so the sooner the better. Please let me know if you need anything. Thanks, Wes 2 SRwRw�[R mAA I I �1 I 4 1 I ~ A DA ACCES [SUT�s b C O MATCH LIM0N a 4 r�� RECORD DRA W/lVG no x s1 11 I B —, U a RECORD DRAWING NOTES I P 1 I �.— a g _oVa'n I. 9FLY1B7 aPAwrNG M1raPJrA iIE?L' PRa5EL1EO Br GRASS aI1R • 1 I 1 I (� N aQ m rn �c aASNB1A0E CAAD AAPSEIEVG LW oEmEPEIP 7 ANa DECOM ER re• 2014.. NWIN STAR 0090Y. LM v EACER PBS MAIL 1 I I I I I I C, N $ 0 m "� ) NC ACCIP75 NO Rl'SPCMWVIY FOP 7NE I I 20 ;0 o zo RO ti ACatRACY CIA'WS M!rUPNA RCN, I I 1 y1 1. RELYRO APAWNC NFCNMAIKN /S SNOMN N /rAucs SCALD V • 20' .E sae aA rY• amov YErr HAs Bmv I 1 I AI (/GREW SEE aftW& APPRat£a PLANS FCN 1 I RW PRCLECr FOP ALL OPAO'NAC VE9W I NAELI7NAMW. l r rEE I W yl 1I aAE OPDMGI I _ M50 ��e 1 I I O I. All SPoT 6[vA110R5 AR 11nalK U1AE5 NOl[D mlpISYY CWtB ARD GUTI[A OR STE IS VERTCN ON A I'PAN. IAM To M UflUlh RYI rM CoPISTRUCTIDV OJPRYATKN OR TIE ST°RY IWS FND APPURlllm S m ,p F. AL OR SR 51WY WAPRAOE r1CLTES SANE W .A TAPAD N I I l I RV SHE PROECT OVARY W 0WER'5 ASSWATIOR. 1 y I 1 "„ to O MASS SVA1( FT Is K %$ 1 I NSTALL OUVALL CURB As HUTa[D tTW1 a1A55 BLtiFR A 1 j I -- AOUFCIDIT PRamn ORE HENL SPRhCE1t PFR mAL 1 I — — — — — — — — — EA�Inr LK o R o69RO V CaRTPlPS z 1 , I I Esc rxn•w S' LPITgwRS 1 I I PRm03D r CanGURS Y O x Y 1 tl I I To N 0-m 1 , IS R --ISI PRW3D v mRTOMS yD I PIIOPJAD RaE1RE N � 'IRG i RANpLAv AFui Y [OICIIEIE PAR n O is 1 I PP.TY1p MIAHAQ I I � A-c=co=c-o oumc WAxAa Prt d 3 � o I 1 � I � r R- n n Msen rtoW a in o a 1 rD MSED WFDE Irv5 0. rLDSUE 1 I 13.r lTR L /6 F Is, HAAR PORT ..~ xu �m MAX. R Y4, LP La• Pon R BOA mQ or 13MALlF [DC [DQ O cOwffEl[ INSI I i:aa N ry 30 W CURB 'Wr�+\� _ MA RY o FSfXALT FA, ,,.,.,••,,,yin,;•: ra 10 a cwwfE h h6M =N -� 1 NN aD aN Pale ] I WOSSwAmAxK. ? R591AP m - GAR aa _ 1 . \-AA? YN� ________ I _ _ _ PLND I I (- t --------------- = ----- 110 = - - - ------ -- - — - -------- ------------------ I' -s - ------------ ---- ,r O WAY lwE fi' LWCRLIE wNR L[CWAOK fENt[ BFCX VIRDE1f CCNSTRL'CTpN URLFR LCMSANCIR'M O SDERN OAMOL -------------------------------- DRAKE ROAD_ iSABR�W°� IRTam SIUM". on" TTrS I aESERAY A TOO RARdCAP RAMPS AS SRCRAI. W UZ a OV JZ J Q z o "oLOR A CALL UTRTER V X CE"tER of caoRAoo CII O 1-800.922.1987 (811) Ac w j.A}L 2-SUSPASS DAYS IN ADVANCE U Rftl+E YOU (AG WADE OR EXCAVATE rW IHE .~0 a INDhW WRo u Bm UlA15IES City of Fort Collins. Colorado UTILITY PLAN APPROVAL APPROFm SHEET p ECIKED BY: watt A wM.MP .10, Dab CHECKED BY: stm .. U.•R, oma MECKm BY: P• A R•o.atM prt. aECKED BY,-4 OF 11 TSaIk &O.mr D.. CHEmm BY. DR. J° NO 339-02 SEE SHEET S RAMP IN N5TALL w]FAa MRS A5 NATOEO ") 4 50EMALK AT ![ 1 SHEDS R/ NAAORAL B TV NYYI M.H928 so FG.HR2B00 MATE-" LOT 1 EN61NW m a A T EAs1bIG MED,NGIl4 � •, � �PRmOSm 1 iOAI(rAN6 Y '--------------- ------------- — J ----- ------ r Eb iO R4` cR,iE.AN M.TE.BFSB y ------------ ------ PARNNG slA To N wRoP LOT 2 L m i RECORD DIVA WING c RECORD DRAWING NOTES $=g; I Sa Pgww a.20 10 0 20 40 'I.A 1 � L_ I L. RECORD DPANIND / CRYAnON P 000 D BY y` WA-WBURN LAND SVRPEKNO OY DECEWAFR 7 r� AND DEam p m 7D/4. NOPM STAR OESGN, SCALE, 1' . 20' 2 I I , EASTNG cME ACCEPTS NO #R- ACCEPNO RESMWS/BN/rY Fat rW rF.l,.w rlll ACCURACY OF TINS MIFORYA AOV. ' 2 RECQ RD DRANRVC AFCRNA 7AaV /S -WAW AR I /rAL/CS , LM CkARY;1, OFSiOV 7EXr HAS ®mu LXil7DOED .SEE QR/OMAL APPROLED PLANS FOR 7NE PRD{Cr FOR ALL OR/O'NAL DESAM t AZ AWORNA 7XIV.. O EWSTNG mCt a ASv1YLT I LOT 1 i O N u r , a p f/ 1gBm RIXYI NtaflITT BQR9YIT ------- I ---------- RT'-------- EC Prd� QAO[ NWI-a-.,T ffY 1\ n naue-_______.-__-___ AOM[pEf•afNTT Y[ � z / / • I ; / w RION PONT - - - - - - - - - LR,TErtESB L,4yB1L 1K LOW"ART EASING t' mxr01AS S ¢Q / • �1/ I \ r SOMADE E IIIO lxiilNG B' C(WmURS w O EDA VXI OF A T y� � 1'.lJ, MCPOSm ,' CMfPMS K iI_r ra__ N PnaPogn B' cavTatts La v ` I mA TUP OF ,�T __ — PRGPosm rtov� - - ____ __ ______ _____a ___ fFAIE-f)YR MA y )R.l I I C-_ _ 1 TCC RP a tllIOKE PI1CP05(D !' MIOIFIE P. t. , I e \ I 1PY Ta a xWl[ PRGPO>ID MANAO AK 2 RX n I F. E,E'ING i ILABNG RAIB (xOT MAxtlUJ RAYP) T. ___ ggyAp ® N a m NOIEII y a R I 1. ALL S'OT N AT ASS RO'AE1E u1A65 NOTES O11ERW5E INSTALL AS HA�IFi® CURB Fill 1WAS AN0 W770R OR SM 6 NRL wnH A 1' PAN. p0 P.IPRPEAH[ s'�mrely a` oB.PPlnidFORN�zaxsmuc�ax woRgAnvl aDT NE ( I c ALL 0, 9R SIO, mmN FACELR9 S vaL BE NANTANED , - _ ______ 'P I i qY TK PRQ4T OVER M ONA'S AS500ATM. RE l -- ----- ---- �' a b —; I F = y C � I I•- E,ESING Iam.HaHs[ I ��, I i j 2 ----------------- -"; PARIq,G OYSR MRS m DE �Aq - L IAN TCINED Am C ! YRCE ]FPRAP R11F BCOET� aENNG �" n I I `�"� -- -i j-/---$-�- "Ss G Bbi. a PAYiYE11T _ _ _ "G IS NAIOI FW PA%NS ______ ____--_- y I MHNTMO FSWT AT TOE1N0 VAWO,� CORMTpDTo AEIlA'mlc,ui AEoU OAT. RNDY BOY TO " 1 n I I tm !K NrfABFD AT wi[ - 1,V� L - _ - - _ _ - _ - _ {L O_ aJ p _ - A{%. A,R,P PBf 1 YFJE N NC WC( NRB WPTIG 3 WC`[ C'R3 GPf.NL PqM 1 F [ASIBIC\ _ _—_- _ ____ __ ___ __ �L—______ __ __ ___ __ n O jL P. B� _____ _ _ --- _ .. _ _ _.- - __mow-_.o...,y. � - - _j Z I Q ____ EY ,s'NL EST rr --- - xm --- - -- — - - - - ----- F J z cl — _ _ __ a sa xm W a r.r Of TTM L awm -_--___ — -' - - - -- -- - - - - - — --- - -- _- - - -- -- — - -- --- -- U ,.�_..m.-- .,a____ -- eHx [K' NF A TYPE L B.NtfD J1Y TYPE E --En T.•�ss"•Lw �E( :_.:.Pa-e.4...� ..� .mr.�.^�,,....� .. " EASING YEFT a SmERAIA Ro'R Evb RIGIn RS,RAP PER [ETLL RENAP MR DETLL S,INSCOHOEIE •AllK .....� c ,}qt "s ....^- -.�: _ _ _ __ a NAT IINi UNDER CCMSTNII(idl WoAAn.E HENCE FAS ALL FRo9O„ Clm ARIA AS HA O SDPE N AREA UNDER Ca15TROCgOH _------- A514TOfL._ -- - CRY of Fort CoInns, Colorado --------------------------- UTILITY PLAN APPROVAL A OVED: `N'm°NA` °°" SHEET DRAKE ROAD MECKED BY: CALL NoTRqCATION UTITER qW A M.MN GI•„ CE O cELH1EN of c0.KnADo LORADO aEam Br: 5 1.800.922.1987 (811) ���- GINY oPN - - - -------------------------------------------- .-.^...--.r.....N ILVAIICE CHECKED BY: Y �roRo`�Ni F�ER XGMoi»o Pv4R ! RwMM Ooh 5 OF 11 w� G OFF ,°A EECKED BY' ,01BFR unL , lr N b�9Nr DON CHECKED BY: 'H0D No. 339-02 Boe. ,R RECORD DRA WING RECORD DRAWING NOTES r -� 1. RELYAPO ARAMS R,IWC V O CaAWRD BY C/]•y a NYC WA9/BURN LANs 4 2014Na O I OST R CIE 2 ANC AFCTMBER l4 ?O111 ft1rY STAR AE9GN, .� V g A. AC ACC r O NO RE9 vRmA AO v. FOR DqE h. ACCTARACY aP Das AVFOPI/ARCN! 2010 0 20 AO }` 2 RECORD ORA BANG / ORMA?)ON IS SMONN /N IrAGCS SCALE. 1• . 20' 3 FOP CEARLrY• AE9OV ?EAT HAS BEEN l/0fWVYD. SET ORIGNAL APPROI(D PLANS FOR D/E PRaAFCT FOR ALL ORYONAL DE90V WF"A DCW. NOTIM 1. Ml SPOT flE In s Aw ftmm UNILSS HUM 0MN � � � d ,na z aw Oro aTru a SITE Is nTRncAL RnR A r vAN. m y. -- a REPEII ro M MUTT REAM ql m61MBOR IlDRN.110A a S M STaMI PT'Q .IAI ARPUIlB11AMii ♦ uE a snE sTuw MAx.a rAaRlo sNALL eE IlAvrtw,m BT M PROEtt O.IIP a OI�ER's ASSOCLIbI I LOT 3 I ' � ' ff I — � 6 UNPLATTED I z I L----- a p m m NAM 2 m a o a Ri.19]s.10 FT.A90).10 I i E1�lEA: � a I PAN Y Y T 3 ARAM ] GlANM'NY fDa OF PASTRENT MAY 2 m 01 (] 1 p i EDGE Or PAIN T MAY I tliATf.M.30 I ' cR.ATE.05.90 T' RAl[ GRATNIR.)S C8 E44TlIG i I P,..,• l GRAIE.tT.10 M 10 [z51N4 [D(L Or SMOLT Gd•GREEE i _ _ Idol i C--M; u+Tcua>[IXSI OF _P_ANT.TEDa DPAMAT I _-_�R AE SRFRAFE' DETAIL__________________________R$__W8_ _ _ _____ 6YT i F;VnGa IlI II F- WMATCH LINE MATCH LlE SEE SHEET 4 I I - I SEE SHEET 6 LL Z Q I - I R I nc BAG I LL. O J 005 d JZ z AAJ Q o Q aa w EFLiBEE U IF R.l9m fttl°i PROPERTY B0.MMT m iYR9m MAW RKHTf -.AT m ftBMlE - AWADERT PRGPOnY IRS w IEOI PgxT _ _ _ E/,pp1T {yE v LIN PwT DEsa¢ r cGRTOIws City of Fat Collins, Cola°do GO GRAa 111 Rs,a Eg511 s• cwmws UTILITY PLAN APPROVAL E04 EDa w ASMALT � 1. [ONiPEs APPROVED: Ea EDGE Or GCNfIRTE 191 MOADMD Y COnIPRs OIIT rP1kw OcA. CALL uTurY NOnEICAnoN CHECKED BY: SHEET -- PR(POSED ftORTE __ IME . RONgr IREIE MIR a Tm a - PRE r ` PAR 1-80 90 2CENIM 2 1987 (811) i0R T� V WR ®f' DRARWS AS 2 ft CHECKED BY: SLamnM uury OWR ---------FIaEIG MANIA PFC a ]-b.=DAYSM AOv RFFDRE You DIG CRADE, q PGAVATE CHECKED BY: rw M RARKvw or �mmrAouRo 6 OF 11 RFRN �� Util� CHECKED Sr.-w— Y: .� Da1R CHECKED BY: NO' 339-02 OolA