HomeMy WebLinkAboutLot Certifications - 08/28/2012Miles City,of. ` elechic. stormwater. wastewater. water Fort Collins OWoSCO0 979.221.6700 970.227.8819 fax . 970.224.8003 TDD urifitles@fogov.com . fogov.com/ufildies CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (a) Date: August 27, 2012 2 Permit Application No. B1102627 Q Usti . Address: 311 North Mason Street Lot: 1 B Block: Subdivision: Penny Flats Subdivision - First Rapist ! I,(Pdnt) . James E. Prelog , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): August 24, 2012 , accurately and truly depict the elevations and drainage pattems as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. 0( The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and . in a manner consistent with the OPpDO I/CFI 60 •• • 3997 •• O 90 la.� 0 NAI By: (signature, PE stamp) 200 S. College Ave., Suite 10 80524 approved drainage plan. SEE NOTE. (address of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lotfslte Including but not limited to drawings of the IoUslte showing the approved design and as -bulk surveyed elevations of all structures, drainage and grading features (e.g. sweles, retaining walls, lot comers), written Informatlonlexplanatlon of discrepancies, and other Information necessary to confine the above certification to: Fort Collins Utilities (970) 2214700 700 Wood Street Fort Collins, CO 80821 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property Rev. 2009 No Text N 1 1 I {341'is) '^ $ AREA�APE� FFE=80.39 y ' S 2! l� 2.0%- � �6 °N-w-- & N 7—RISERS (SEE ARCHITECTURAL PLANS FOR DETAILS) t i o w ) z.0% I /bg .- 6" SANITARY SEWER " + P._ QX o SERVICE pX �'i•, /� (PER PENNY FLATS OVERALL UTILITY PLAN) K N APPROXIMATE LOCATION .. '67 OF EXISTING SANITARY SEWER LINE. CONTRACTOR '^ ® TO VARIFY LOCATION PRIOR © TO CONSTRUCTION 5 •••;•I LANDSCAPE STRUCTURAL WALL I - •-' ' II qo AREA (SEE ARCHITECTURAL ELEVATED E FOR DETAILS) - ETE SLAB ©® FFE=83.80 14 - 42 o (�.15Jn V Z 0 It _ g 6' SANITARY SEWER 20F I I Z SERVICE (PER PENNY FLATS 1 OVERALL UTILITY PLAN) LANDSCAPE AREA ED © ; 4.0% o Iw9el' PROPERTY LINE RAMP LDSCAPE El ••. AREA 0 6" STORM SEWER 2.0% M'05 ' ST u ------------------- ---- - - ti �$ RAMP 6" STORM SEWER N I IF i -- -- -- -- I -------------------------------- I---� ---—-————--——-—------------ — I In � II %YoC�i0s7:i� A ------------u..........................................u..u. 8 .°cxm 9yi 3 gg 4 94�eA2 !1 0 C> Z y 3d� NJ I MY � � MASON STREET FLATS Ci v iN�9j i�� ii 0 A 0 l O, i''i9 !qp 10.013 ' 11 ggll 311 NORTH MASON ST. FORT COW NS, COLORADO