Loading...
HomeMy WebLinkAboutSite Certifications - 02/02/2007NORTHERN ENGINEERING February 2, 2007 Mr. Jay Barber Stormwater Utilities City of Fort Collins 700 Wood Street Fort Collins, CC 80524 ADDRESS: PHONE: 970.221.4158 200 S. College Ave. Suite 100 WEBSITE: Fort Collins, C080524 FAX:970.221.4159 www•northernengineering.com RE: Plantation Manor Site Drainage Certification Dear Mr. Barber, STORMWATER RECEIVED FH 0 2 2007 This letter is in regards to Plantation Manor at Big Ben Drive and West Horsetooth Road, and in particular, to provide a final certification of the drainage facilities. A partial certification was submitted to your office November 3, 2006; the certification stated that the spillway of the pond needed to be raised 3" to provide the required volume. The pond spillway elevation was raised on or about November 17, 2006 by approximately 3", verified by a site visit in late November 2006. The raised spillway increased the capacity by approximately 5,400 cf to a total volume of 63,600 cf; 63,500 cf is the required detention volume for Plantation Manor. Drainage facilities were examined during the site investigation; all inlets, pans, and storm sewer appear to be in good working condition. The pond outfall near Seneca was also examined, the pipes and inlet also appear to be in good working condition. In conclusion, the site drainage is complete and; all facilities are anticipated to perform as designed. The overlot grading does essentially follow the proposed grading plan. Please feel free to call should you have any questions regarding this certification. Sincerely, ENG Roger A, Curtiss, P.E' Project Manager . cc: Brett Latimer 0? 14A`07 As -Built volume south 02-02-07.txt PLANTATION MANOR Elev Area Avgg Vol Cumml Avg ft ac ft3 ft3 5109.70 0.598 2528 61018 5109.60 0.563 2315 58490 5109.58 0.550 2275 58100 5109.50 0.500 2116 56175 5109.40 0.471 2004 54059 5109 0.4 1 52055 �-5I'69-20 0 0.43030 , 1830830 'STl1� 5109.10 0.411 1752 48311 5109.00 0.394 1691 46559 5108.90 0.383 1651 44868 5108.80 0.376 1622 43217 5108.70 0.369 1594 41595 5108.60 0.363 1571 40001 5108.50 0.358 1551 38430 5108.40 0.354 1536 36879 5108.30 0.351 1522 35343 5108.20 0.348 1508 33821 5108.10 0.345 1494 32313 5108.00 0.341 1480 30820 5107.90 0.338 1466 29340 5107.80 0.335 1452 27874 5107.70 0.332 1438 26422 5107.60 0.329 1424 24984 5107.50 0.325 1410 23560 5107.40 0.322 1397 22149 5107.30 0.319 1383 20753 5107.20 0.316 1369 19370 5107.10 0.313 1355 18001 5107.00 0.309 1341 16646 5106.90 0.306 1326 15305 5106.80 0.303 1311 13979 5106.70 0.299 1294 12669 5106.60 0.295 1274 11375 5106.50 0.290 1250 10101 5106.40 0.284 1226 8851 5106.30 0.279 1201 7626 5106.20 0.273 1176 6424 5106.10 0.267 1146 5249 5106.00 0.259 1054 4103 5105.90 0.225 848. 3049 5105.80 0.165 642 2201 5105.70 0.130 503 1559 5105.60 0.101 384 1055 5105.50 0.075 286 671 5105.40 0.056 208 386 5105.30 0.040 132 177 5105.20 0.021 46 46 5105.10 0.000 0 0 Page 1 As -Built volume north 02-02-07.txt PLANTATION MANOR Elev Area Avg Vol gt3 Cumml'Avg ft ac ft3 5109.70 0.077 319 2552 5109.60 0.070 296 2233 5109.50 0.066 277 1937 5109.40 0.062 259 1660 5109.30 0.057 241 1401 5109.20 0.053 223 1160 5109.10 0.049 199 937 5109.00 0.042 166 737 5108.90 0.034 133 571 5108.80 0.027 109 438 5108.70 0.023 91 329 5108.60 0.019 73 238 5108.50 0.015 58 165 5108.40 0.012 44 107 5108.30 0.009 31 63 5108.20 0.006 19 32 5108.10 0.003 10 13 5108.00 0.001 3 3 5107.90 0.000 0 0 Page 1 n� INORTHERN ENGINEERING ADDRESS: PHONE: 970.221 .4158 WEBSITE: 200 S. College Ave. Suite 100 www.northernengineering.com Fort Collins, CO 80524 FAX: 970.221.4159 November 27, 2006 STORMWATER Mr. Jay Barber RECEIVE® Stormwater Utilities City of Fort Collins NOV 2 8 2006 700 Wood Street Fort Collins, CO 80524 RE: Plantation Manor Site Drainage Certification Dear Mr. Barber, 1 This letter is in regards to Plantation Manor at Big Ben Drive and West Horsetooth Road, and in particular, to provide a partial certification of the drainage facilities. A survey conducted in July of 2006 provided the topography for this certification; a site visit November 3, 2006 confirmed drainage patterns and facility conditions. From the topography, the combined pond volume is calculated to be 58,100 cf. The design pond volume totaled 63,500 cf, or 5,400 cf short of storage. The pond spillway elevation was raised on or about November 17, 2006 by approximately 3", which increased capacity to 63,600 cf, slightly more than required. Drainage facilities were examined during the site investigation; all inlets, pans, and storm sewer appear to be in good working condition. The pond outfall near Seneca was also examined, the pipes and inlet also appear to be in good working condition In conclusion, the site drainage is complete and; all facilities are anticipated to perform as designed. The overlot grading does essentially follow the proposed grading plan. Please feel free to call should you have any questions regarding this certification. Sincerely, NORTHERN ENGINEERING oveooiN Roger A, Curtiss, RE 27362 Project Manager cc: Brett Larimer ���iiij�FSSION I . - PLANTATION MANOR PARTIAL DRAINAGE CERTIFICATION 200 South College Avenue, Suite 100 Fort Collins, Colorado 80524 NORTHERN ENGINEERING PHONE: 970.221.4158 FAX: 970.221.4159 v .northernengineedngxotn ILT POND CONTOURS NO UTILITY FEATURES ARE V FOR REFERENCE ONLY PLANTATION MANOR AS -BUILT PONDS DRAWN BY: K. Dail SHEET NO: SCALE: 1 "=60' ISSUED:11-06-06 1 of 1 w. R O O Ot A i late fa g .t 0 Q 0 I H 0 0 w