HomeMy WebLinkAboutLot Certifications - 08/01/2001AVRES ASSOCIATES July 27, 2001 Mr. Jay Barber City of Fort Collins StormwaterUtility 700 Wood Street Fort Collins, Colorado 80521 Re: Drainage Certification for Building Envelope C, Lot 1, Care Housing at Windtrail Park PUD Dear Jay, We recently surveyed Building C of Lot 1 of the Care Housing at Windtrail Park PUD to verify whether the grading met the intent of the approved grading and drainage plan. Spot elevations were checked at pertinent locations and compared to the grading plan. The enclosed drawing shows these as -built elevations. In general, the lot and building meet the requirements of the grading and drainage plan and there is positive drainage away from the building on all sides. The intended drainage patterns are met by the grading on this lot. the north part of the building drains north to the parking lot and the south part of the building drains southeast toward the sidewalk, which serves as the main conveyance channel between the buildings. The finished floor elevation varies from 5014.2 to 5014.8, which is identical to the proposed grading plan. The spot elevations show positive drainage away from the building, with a minimum slope away from the house of 1.3% (0.16 feet over 12 feet). It is my recommendation that the Certificate of Occupancy for Building C of Lot 1 be released since the Contractor graded the lot to meet design drainage patterns. If you have any questions, please call. Sincerely, Owen Ayres & Associates, L. Doherty, RE. Project CLD:sp Enclosure Owen Ayres & Associates, Inc. Eng i nee rs/Scientists/Surveyors 3665 JFK Parkway, Building 2, Suite 200, P.O. Box 270460, Fort Collins, CO 80527 (970) 223-5556, Denver Metro (303) 572-1806, FAX (970) 223-5578 CHWT-7C.DOC 32.0287.00 Printed on recycled paper � I I o 77 77 LL i LL o� LL � wZ z w LL -� I LL I I � � r v i LL LL a. j a o� e� s to �a i I Ol ------------ - �06 £ i Z14J09 -. 9'tF W9 =44 9,K09 8'tr W9 9L'£ 09 — '' 0 4 01409 dH �914 .9 V'9 l _-4 E,6Z'71.09