HomeMy WebLinkAboutLot Certifications - 10/09/2008City of Fort Collins Date: 1112 Utilities electric e stormwater • wastewater • water CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Permit Application No. / p� Address: 4.24 ��`� /%l�f%'Pe�' /v Lot: I ftT (8 Block: Z:-O Subdivision: OtLa ALt 4y LwRc� , Aj. a Colorado registered professional engineer, have personally Inspected the above referenced property in the City of Fort Collins, Colorado, and verify that construction of all stormwater facilities and grading there is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (information attached). SEE NOTE. The elevations and drainage patterns of the lot as measured are in general conformance wWrtlie . In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent, VW,th_e ,moved drainage plan. tip° G A2_ SEE NOTE:_By. I ; �� (signature'01; PE stamp) .-*4,"�� -25 (address of rici'paitvl NOTE: t A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design or revised design and as -built surveyed elevations of all structures and drainage and grading features (e.g. swales, retaining walls, lot, corners), written information/explanation of discrepancies, etc. to: Fort Collins Utilities (970) 221-6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property 5,� /6 j rs I bg FINAL GRADE PLAN SAVANT HOMES 620 WEST OAK STREET FORT COLLINS, COLORADO 10-8-08 5.2 N89d59'27"E 45' 4.5 I I I I 1 I I I o I to o j Io w I 13 o I 14 o I to o I, to z j j� I I I I I I I I 1 4.6 4.4 4.3 i 4.9 4.7 WW 5.0 j „ Inr �r j BASEMENT j `�• �' j FF=6.7 j w 1# 2 3.9 4.6 4.5. + 3.9 4.2j w �'�.,..o,..• j .4.1 • I "reh 6 -------------------- 3.7 N89d59'36"W 45' 2.8 I HEREBY STATE THAT THIS GRADING PLAN WAS PREPARED FOR SAVANT HOMES, THAT IT' IS NOT A SURVEY DOCUMENT, T A LAND SURVEY PLAT, OR AN IMPROVEMENT SURVEY PLAT, AND IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT 11 \\I OF FENCE, BUILDING, OTHER FUTURE IMPROVEMENT LINES, OR MONUMENTED ELEVATIONS. TEMPORARY BENCH MARK USED WAS.THE SOUTHEAST PROPERTY PIN ELEVATION PROVIDED ON THE SITE PLAN BY NORTH STAR DESIGN. PEEKS & ASSOCIATES 1" = 30'-0" m r F G m O r § 1 0! z O { 5 } mFn o I I a 3� I I � � I I I I DLb— � I m 1 I I n fi I g8 i IMP � ICI xoam rroorotw4 amvtuw ALLEY as a= to RE 6 6 EEE9� dr r i� eaa: s/3t/Oa1,01 NeR sw BT O.1E , 620 WEST OAK STREET Norid Star ua.: r-to' ',� design. Inc. I o.ugn.a er PPK q00 Yaangm dM.{ktll e _ SITE PLAN vma.n,cobaaoegsao pl. 9 Bg68B. — Oram Oy. PPa F. B)<IaB6111019a r