HomeMy WebLinkAboutLot Certifications - 05/28/2014l QUALITY `x ENGINEERING W W W. QUALITY-ENGI N EERI NG. COM OVERALL LOT CERTIFICATION CERTIFICATION OF LOT GRADING Date: March 28, 2014 Permit Application No. B1206691, B1206714, B1206715 Address: 5233 Boardwalk Drive, Fort Collins, CO. Lot/Block/Subdivision: One Boardwalk Place QUALITY ENGINEERING, LLC (970) 416-7891 1501 ACADEMY CT, SUITE 201 FORT COLLINS, COLORADO 5223 Boardwalk Drive Fort Collins, CO 80525 City of Fort Collins Building Permits: B1206691 COMMERCIAL, MULTI -FAMILY AND SUBDIVISION 81206714 CERTIFICATION CHECKLIST B1206715 One Boardwalk Place Please fill in all applicable items in this Certification Form for Commercial, Multi -Family and Overall Single Family sites. A copy of the approved grading plan must be submitted with the as - built grading plan. Use "OK" for items checked or actual numbers for items verified/surveyed in the field. Use "N/A" for items that are not applicable to the site that is being certified. Please provide an As -Built Redlined or Mylar drawing showing the following: A. Detention Facilities Certification `J I )� 1. Pond Certification • Provide Topographic Records and Volume Verification Calculations • Provide Pond Cross -Sections and Spot Elevations (especially @ Pond Embankment and Pond Flow Line) • Positive Fall to Pan (if applicable) • General Pond Grading including all Side -Slopes • Invert Elevation • Forebay Construction and Elevation • Spillway Weir (Location, Elevation, Height, Opening Width) • Placement and size of riprap or alternative permanent erosion control measures • Orifice Plate and/or Water Quality Outlet Structure Installation • Water Quality Capture Volume (Volume Required, Volume Provided and Water Surface Elevation) • Berm and Embankment Compaction Level • Subsurface Media for Water Quality Ponds and Swales I CA- oI't`� �S 2. Swales Me • Location (are they within easement?) Nllk • Dimension and Cross -Section Verification bl_ • Longitudinal Slopes and Side -Slopes Oh • Spot Elevations �I� • Permanent Erosion Control Measures (drop structures, riprap, lining) (�� • Tie-in to Storm Lines, Pans, Curbs, or other appurtenances 11.114 • Required Minimum Freeboard, Provided Freeboard Ott • Landscaping Infringement on Flow Line? 3. Pipes p(� Size and Type pk • Slopes (As -Built and comparison to 0.4% Minimum) M1r� 4 • Pipe Capacity Calculations (if slopes are significantly altered from design) vk • Invert Elevations �!/� • Installation and Backfill 4�C • Cover f//A • Encasement and Clearance from other nearby utility lines tv14 • Joints Type and construction 2 C�G N I1� 4. Concrete Pan Channels aySRi�Z"� • Size Pitv�E��RttY , CTE • Slope [uri.R • Cross Section • Thickness • Elevations 5. Inlets 0 it • Size and Type 0u • Size of Opening (or name of Standard Detail used) plc • Grate Elevation 0Jf • Invert Elevation 0 )C • Box Size VIA 6. Street Cross -Pans �y=STS" i • Size • Type • Grade • Elevations • Cross -Sectional Depth • Tie-in to Curb and Gutter Fit 3 CAG 7. Culverts • Size • Type • Invert Elevations • Headwalls or Wing Walls N(A B. Sub -Drains • Size • Type (Perforated/Solid) • Cover • Backfill • Geo-Textile Liners • Clean -Outs 9. Curb Cuts k • Size C,k • Tie-in to Swale, Pipe or other appurtenances N ( B. Certification of Grade Elevations Adjacent to Drainage Facilities: • Minimum Opening Elevations • Top of Foundation Elevations • Comparison to 100-year Water Service Elevations • Comparison to Freeboard Elevations and Base Floodplain Elevations — BFE 4 l I G Fort of - ,-- Stt� C. Certification of Erosion Control Measures: 1. Permanent BMP Measures: 6�- • Permanent Vegetation (no more than 6" bare spots and weeds under control) pbf • Riprap or alternative permanent erosion material VIA- • Riprap Bedding V IA • Cut -Off Walls or Channel Drop Structures Cross -Sections Nw, • Sediment Basins N Jfh • Water quality ponds/Sand Filter/Bio Retention Construction and liners NIA • Permanent Netting Mats or Blankets Ck • Mulching and Seeding 2. Temporary BMP Measures: 0 Mulching and Seeding C�_ • Temporary BMP Measures as shown on Erosion Control Plan D. Post -Construction Site Cleanup: �(� • Construction Debris Clean -Up p • Smoothing of Ruts in all Construction Areas i k Reseeding of all Areas Affected by Construction Activities 5 GPI Fort Collins E. Statement of Compliance: This certification is signed and stamped and by signing this form the Engineer(s) attests that they have inspected the site and to the best of their knowledge the as -built conditions of the drainage facilities are as described in the above form and in the As -Built plans enclosed. Failure to properly disclose all known information could result in the rejection of this certification and prevent the release of any and all Stormwater Utility permit holds on Building Permits and/or Certificates of Occupancy within this development. F. Signature and Stamp by a Colorado Registered Professional Engineer No Text C) Daniel Mogen From: Michael Palizzi <michael@quality-engineering.com> Sent: Friday, March 28, 2014 4:11 PM To: Daniel Mogen Cc: Shellenbarger, Andy; Brett Brown (bbrown@dohnconstruction.com); Cody Geisendorfer, Gary Floyd Subject: One Boardwalk Certification Attachments: One Boardwalk Overall Lot and Grading Certifcation.pdf; One Boardwalk Place Grading Plan.pdf Dan, Attached is the One Boardwalk overall lot and grading certification. A berm has been added to the inlet on the hill at the northeast side of the site to alleviate the concern of water flowing directly over the inlet and down the hill. There is a _ ..picture of -this attached at_the_end of the certification. As you have already transferred the asbuilt shots to the proposed grading plan, I have not done so for this. There have only been a few shots added since the last submittal. These new shots have been added to our asbuilt exhibit (attached at the end of the certification). For future submittals we will transfer these shots ourselves. Let me know if you have any questions. All the best, Michael Palizzi, El Civil Engineering Designer Quality Engineering, LLC Civil and Structural Engineering 1501 Academy Court, Suite 201 Fort Collins, CO 80524 (970) 416-7891 office (970) 797-1182 fax (303) 319-1385 mobile www.gualitV-engineering.com BOARDWALK DRIVE 111L1fm I 1 - CONDO 1 dp COAIPLE% FF = 7090,/- 1 yam •�• y` tl�� I ) — IFcoroL� (aesel � ta�en i � � I i -_— v+� I �1 o O n -1 I axex - .M1 ( .1 i condo COMPLEX q Ell �cm• - r _ FF = 7160 L 1 % I FF 70.08 I � �_ � � oa•n- I vim.,, ,;' I �-�3a � i ' I I �I jl I ��I� i y� L, - I I FF = 7080' 1 -� n' ( e,r 1 1�:'ew$ ria I GARAGE C FF=7128' r--__ Irossl x �I✓ai: I I ,-0 I � /j-�.o GA _ , d -' n+:✓ Faun) � _ -�-7. _ I :�`I I •, "I I I RACE I I ,Y „) GARAGE F1 _ \ ❑CFir719' I I 1 (\ < ao - -) ne wl I I - 7L87. i a.°�.. & y �ta• 01 1. b • ¢_ a r m L m Z C m NOTES: 1) AS -BUILT SURVEY POINTS PROVIDED BY WASHBURN LAND SURVEYING AS PERFORMED ON 08/22/13, 01/02/14, AND 03/20/14. 2) ALL FINISHED FLOOR ELEVATIONS ARE APPROXIMATE. SYMBOL LEGEND RIGHT-OF-WAY/ PROPERTY LINE -- __ ---- EASEMENT LINE -- - - - - - - BUILDING LOT CURB/GUTTER SIDEWALK BUILDING EXISTING 12" _ - - PVC STORM (TYP) 8" PVC STORM h njh L� AS -BUILT ELEVATION ❑ 12"x12" AREA DRAIN NOR TH 20 0 20 40 P=20' w r Q O m m N Z O N S W O Z CHECKED: CAG DESIGNED: MAP DRAWN: MAP DATE: 03/28/14 SCALE: AS NOTED PRDJ#: 1034-028 EX.1 "SUNG CWO TD MAUL. COISTMS soEMAa ro wUal '�/�Ey {! -- --------------------- �I i EIOSRIIO 24- A05 ( I II' BASM 1M) y�,Ell5R4G BOARDWALK DR - - - — E,OSTWG S1WY E9151N6 MAIN TO REMMN SID III TO REMNN- MAIF_{O.SG ---- - �-a------' -------- r-- ---------Y496 T---�='------- _---mT'- _ , �- 1 V9B ,g H SIB �s a g STEPS E CISTND 12' JJ99 PW STORM 4 I 9 (TP7 R FG_)¢.m CONECr 1 TO Ea ri .p OT¢ I NRO ! +I MTRR J ?� EKING I ENS1N¢ 1�1�ii mar M�97 NOW �I y S 1L I WE A HJ i F _I FRONSED 6.0' CONCRETE WALK I I I I I I PROPOSED emOQHG L , , \ FF.T.50 � 10 6 6 tb aI� 6 GYTRR r 11 b SHIe DPa4rw 11 cum VIDING h I PROIPWED '"°"_ I, .15 OPEMM - I T� \ OUIfM1 LINO h_ - \ AS MATam. aB) 44 I� 49 M_BnTs EMONG 12- OmnNG FF_T SD BININl6 )STORM fW71.m M-11.50 FA .m 9)F N M� _ 9) 49> Ens W M.1LL (11P) TRACT C SOEMMN To RaIAN. i EXISTING FAMESE!, WALL, WILDING ..-+r . WON - — C N � N O m � � mm 0 otgm v Cl 5�C `Dads � C E 20 10 0 20 40 `4R m o p n O C L SCALE, 1" = 20 ^C a r` d LLR W H 0 LEGEND 1. RFFa TO DENK I1Wv PLAN FOR ASPHALT HNDVN. CN TO STIMOHY CLEW EDGE. 2. CONTRACTM SHALL Y RESPONSIBLE FOR ME REPLACEMENT CF ANY OWADN LYRE 6 GUTTER. S. ALL. SIDEMILPS MN CAVEMAYS SHALL SE CONCRETE. ♦. ALL SCEMALNS SHALL HAW A MAINOW CROSSE S-WE OF 2%6 A MAAWM AWE IN THE WRECiIM TRAWL Or SOX UNLESS NOTE➢ OTHERMSE, IN MY AICA THAT THE --E M THE DIRECTION OF IRAWL EXCEEDS SR 6 THE RISE IS MEW THAN a'. «AAMALS ME III a. FMY$IED DRIVE AT THE FWNDATDI ICH M ALL SLI NGS S1ML SE A MMIMVM OF B- BELDM THE nNS1E0 ROOR AFTER ALL LANDSCAPING IS IHSTAII DO, 0. rMSHED MADE 9 FALL A WMIMW OF a' M THE FIRST 10AWAY MR THE FOUNOATIQI MALL AFTER ALL IAMOaCAPWO 15 INSTALLED. ). THE REAR MALL OF ALL WAGE 0ULLON45 SHALL HAW A FWNOAIIM TO AN ELEVATION 0- ASOW THE E Mn%S SHDW. 0. REFOR TO SECDM 34.1 OfME LAND USE CODE FOR ALLOWABLE USES NIHON THE NAIIIRtI HANIAT SUFFER EOIE PF FINISHED ROM _ _ PROPERTY ECONOMY FG FwMEE, MADE - roMT-O-WAY F. FLDWLNE ADJACENT PROPLYTY WE HP WM PONT — EASEMENT UHE LP LOW PONT COSTWG I' COHYDIRS O1 GRADE 9REAIt -- 1910 EASTWG Y DOiiWRS EOA EDDE Or ASRHMT FRUIOSED V CMTWRS Ex EIXE OF coic"I 4910— -HOSED S CONTWR9 MA TOP O ASPHALT ..—...—...—.. PRMMED M1ORllIE TOO TOY O COW ETE PROPOhfp N LON qMO iM FINISHED MASH AT - %ICPOEED OJ1FM1 ONOI To, OF Ma BYI fIHSHED MACE AT PRMOYD Y CCMCFETE PAn SETT. OF WALL PRMOSED DRADAGE PPE IBM NY Or MALH EMSTWC MANAEE P&E TM TM O POND RPRM OFF GMAM FWISHED'LOM Z S K 3i306 xE c W U Q J a Y Z J a Q a z oz ccQ Q� E40 W W z 0 City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROYED: Oly Dn9N4r pate SHEET CHECKED BY: WaHY k 1MbHIctw UIFLF m. UTILITY NOTIFICATION CENTER OF COLORADO CHECKED BY: 5CALL 1-800-922.1987 5RMm_aTM UMII) Dal. CALL 2-BUSINESS DAYS IN OVMCE BEFORE YOU DO, GRADE. M EACAVAM CHECKED BY: Poke A R..U- Date FM THE MMKAB OF UNDERMOM1p CHECKED BY: 5 OF 8 MEMBER UTILITIES, TnMc EDlynev Date CHECKED BY: Job NO 223-05 EnwaH,a.,ta Hmn.. Daee Glen Schlueter From: Glen Schlueter Sent: Friday, December 20, 2013 2:23 PM To: 'bbrown@dohnconstruction.com' Cc: ' •' ichaelp@quality-engineering.biz); Daniel Mogen Subject: _'Cod : One Boardwalk Place Certification Brett, Dan and I did get out to the site yesterday. The grading and drainage is in pretty good shape. There are a couple of items that are different than what the plans show. I talked with Michael Palizzi with Quality Engineering about these so I think he understands what is left to do to get the escrows released. /There was no survey information on the Swale along the west side of the property but the Swale is there and looks correct. XThere is information missing in the NE corner of the site including info on a Swale that isn't there but is shown on the plans. I gave Michael the option to justify why it isn't needed or to actually build it as shown on the approved plan. I am guessing it was to capture roof drainage so it would not flow over the sidewalk. Right now the grate is on a slope so no w ,q ter can drain to it. — �itry a&4 • 0 taia� � '- wop.,r " a -UV ' drslwivz:� ..io 6�L - In the very NE corner there is was supposed to be a grate on a riser but instead there is a solid lid. Even if it was a P. !grate it would be so high no water could get into it. It acts more as a clean out for the storm drain. Again it can be fixed or explain away. It doesn't appear to be needed as a grate since it is on a slope. F0.0 at The survey information was on a separate plan sheet so it made it more difficult to compare the approved grading plan to the as constructed grades. Dan transferred all the elevation spots onto a copy of the approved plan. Please show^+ the additional elevations shots on a copy of the approved plans The grading certification form has been altered from out standard form and is on Quality Engineering letterhead. Please use the standard form. I explained to Michael that the Overall site cert. is for the infrastructure like ponds, swales, pipes, inlets, grates, etc. What was done is a combination of the Overall site certification with the grading certification. I don't see a reason to make them break it down to the normal steps since it is already done and this is a fairly small project. We usually get a separate grading certification for each building as they are finished that can include the associated driveways, parking area and/or garages. I think that was it. Dan if you see something I missed please respond to this email message. Once these issues are resolved I will release the escrow, Glen Schlueter 224-6065 From: Brett Brown [mailto:bbrown@dohnconstruction.com] Sent: Wednesday, December 18, 2013 11:24 AM To: Glen Schlueter Subject: RE: One Boardwalk Place Certification I was able to get them all today, thanks! Let me know when you are able to complete the inspection so we can get our escrow back. Thank you, Brett Brett Brown, LEED AP, CPC Director of Field Operations Dohn Construction, Inc. 970-490-1855 (CO) 307-634-6177 (WY) 970-490-6093fax bbrown@dohnconstruction.com Please consider the environment before printing my email From: Glen Schlueter [mailto:GSCHLUETER@fcgov.coml Sent: Tuesday, December 17, 2013 5:03 PM To: 'Brett Brown' Subject: RE: One Boardwalk Place Certification Brett, I just got your email and the building department is closed. Maybe we should call them together because what I see on the computer is a blank for SWEng Final. I have meetings most of the morning but I will be at that building and can check with them between meetings if there is a long enough brake. I think you can go online and see it too but I don't know the process. Hopefully we can get this decided tomorrow. Glen From: Brett Brown [ma iIto: bbrown(cbdohnconstruction.com) Sent: Tuesday, December 17, 2013 11:26 AM To: Glen Schlueter Subject: Re: One Boardwalk Place Certification No that is how it appears to me also but the clerk at the counter would not give me the CO siting thatSW Eng. had not signed off. I will go back and try again. Brett Brown Dohn Construction 970-566-1294 On Dec 17, 2013, at 11:17 AM, Glen Schlueter <GSCHLUETER@fcgov.com> wrote: Brett, I checked in Accela and SW Eng. Final is blank on both of these permits. I don't have anything to release. Did you find something that I am not aware of? Glen From: Brett Brown [maiIto: bbrown@doh nconstruction.coml Sent: Monday, December 16, 2013 7:16 AM To: Glen Schlueter Subject: RE: One Boardwalk Place Certification When I went to pick up the CO's and found that B1206713 and B1206709 still have holds on them. These are the building permits for the associated garages on this project. Can you please release these as well? Sorry for the confusion but the hold did not show up before and now it is there. Let me know, thanks for the help. Brett Brett Brown, LEED AP, CPC Director of Field Operations Dohn Construction, Inc. 970-490-1855 (CO) 307-634-6177 (WY) 970-490-6093fax bbrown@dohnconstruction.com Please consider the environment before printing my email From: Glen Schlueter [mailto:GSCHLUETER(d)fcgov.com] Sent: Tuesday, December 10, 2013 11:16 AM To: 'bbrownCcbdohnconstruction.com' Cc: 'Cody Geisendorfer' Subject: RE: One Boardwalk Place Certification Brett, I have released the SW Eng. Final hold on permit numbers B1206691, B1206715, & B1206708. The system was finally fixed this morning. The escrows will be held until we can see the ground enough to complete the site inspection and acceptance. Glen 224-6065 Brett, I did look into this and since we have the escrow and the certification in hand so I can change the TCOs to COs. The Accela (Permit system) program is down today so as soon as it is fixed I will change them to Cos. As soon as we can see the ground good enough we will do the site visit and release the escrow $. If the weather forecast is correct we should be able to do it maybe as early as Wednesday but Thursday or Friday are probably better bets. Glen 224-6065 That sounds reasonable, let me look into it Monday afternoon. Glen From: Brett Brown[mailto:bbrown(&dohnconstruction.coml Sent: Friday, December 06, 2013 1:41 PM 3 t: To: Glen Schlueter Cc: Jay Barber; 'Cody Geisendorfer' Subject: RE: One Boardwalk Place Certification Hi Glenn, we have already escrowed for this so that we could get our TCO, with our escrow can you release the full CO? Brett Brett Brown, LEED AP, CPC Director of Field Operations Dohn Construction, Inc. 970-490-1855 (CO) 307-634-6177 (WY) 970-490-6093fax bbrown@dohnconstruction.com Please consider the environment before printing my email From: Glen Schlueter [mailto:GSCHLUETER@afcgov.coml Sent: Friday, December 06, 2013 11:51 AM To: %brown(Nohnconstruction.com' Cc: Jay Barber; 'Cody Geisendorfer' Subject: RE: One Boardwalk Place Certification Brett, This issue now is the snow. It is pretty hard do a site grading inspection with the ground covered up. The alternative for weather related delays is to escrow $2,500 per building permit. If you want to wait until next week to see if the snow melts enough we can do that. I have temporary help that hasn't done an overall site inspection. My schedule looks like I could go with him next Tuesday or Wednesday afternoon. Let me know what you prefer, Glen 224-6065 From: Brett Brown[mailto:bbrown@dohnconstruction.coml Sent: Thursday, December 05, 2013 5:26 PM To: Glen Schlueter Cc: Jay Barber; 'Cody Geisendorfer' Subject: RE: One Boardwalk Place Certification Glen, the owners have been pushing us pretty hard to get this document. Anything you can do to help get it released would be greatly appreciated. Please let me know what I should tell them for timing expectations. I believe the documents are in the format that was requested, please let me know if that is not the case. Thanks, Brett Brett Brown, LEE AP, CPC Director of Field Operations Dohn Construction, Inc. 970-490-1855 (CO) 307-634-6177 (WY) 4 J 970-490-6093fax bbrown@dohnconstruction.com Please consider the environment before printing my email From: Glen Schlueter [mailto:GSCHLUETER(a)fcgov.coml Sent: Thursday, December 05, 2013 5:00 PM To: 'bbrown0dohnconstruction.com' Cc: Jay Barber; 'Cody Geisendorfer' Subject: RE: One Boardwalk Place Certification Brett, Jay has been out since September 30`h and we don't expect him back until sometime after December 11. We do need to do a site inspection to verify the overall certification and with the snow it could be we won't be able to do it until it melts some. I have temporary help but I need to know how urgent these COs are. Please let me know or give me a call. My understanding is the certification discussed below is for the overall site cert. and not the individual lots. So do you plan to submit them or what is going on here? Glen 224-6065 From: Brett Brown [mailto:bbrown(abdohnconstruction.com] Sent: Thursday, December 05, 2013 4:51 PM ' To: 'Michael Palizzi'; Jay Barber Cc: 'Cody Geisendorfer'; Glen Schlueter Subject: RE: One Boardwalk Place Certification Jay, the three permit numbers for this project are B1206691, B1206715, & B1206708. If you could please let me know when you have released these I will be able to come get the CO's. Thanks for the help! Brett Brett Brown, LEED AP, CPC Director of Field Operations Dohn Construction, Inc. 970-490-18SS (CO) 307-634-6177 (WY) 970-490-6093 fax bbrown@dohnconstruction.com Please consider the environment before printing my email From: Michael Palizzi [ma iIto: michael ftuaIity-engineering.coml Sent: Thursday, December 05, 2013 4:02 PM To: ibarberOfcgov.com Cc: Cody Geisendorfer; gschlueterOfcgov.com; Brett Brown (bbrown@)dohnconstruction.com) Subject: One Boardwalk Place Certification Jay, Attached is the certification for: One Boardwalk Place 5223 Boardwalk Drive Fort Collins, CO 80525 All outstanding items have been taken care of for this site, including the outlet structure modification (see attached picture). Please let me know if you have any questions. All the best, Michael Palizzi Engineering Intern Quality Engineering, LLC Civil and Structural Engineering 1501 Academy Court, Suite 201 Fort Collins, CO 80521 (970) 416-7891 office (970) 797-1182 fax (303) 319-1385 mobile www.guality-engineering.biz 6 Y 5223 Boardwalk Drive Cltyof Fort Collins Fort Collins, CO 80525 / N�tf� COMMERCIAL, MULTI -FAMILY AND SUBDIVISION CERTIFICATION CHECKLIST One Boardwalk Place Please fill in all applicable items in this Certification Form for Commercial, Multi -Family and Overall Single Family sites. A copy of the approved grading plan must be submitted with the as - built grading plan. Use "OK" for items checked or actual numbers for items verified/surveyed in the field. Use "N/A" for items that are not applicable to the site that is being certified. Please provide an As -Built Redlined or Mylar drawing showing the following: A. Detention Facilities Certification � I J� 1. Pond Certification • Provide Topographic Records and Volume Verification Calculations • Provide Pond Cross -Sections and Spot Elevations (especially @ Pond Embankment and Pond Flow Line) • Positive Fall to Pan (if applicable) • General Pond Grading including all Side -Slopes • Invert Elevation • Forebay Construction and Elevation • Spillway Weir (Location, Elevation, Height, Opening Width) • Placement and size of riprap or alternative permanent erosion control measures • Orifice Plate and/or Water Quality Outlet Structure Installation • Water Quality Capture Volume (Volume Required, Volume Provided and Water Surface Elevation) • Berm and Embankment Compaction Level 0 Subsurface Media for Water Quality Ponds and Swales City of Fort 2. Swales Ole Location (are they within easement?) j Ilk • Dimension and Cross -Section Verification pk • Longitudinal Slopes and Side -Slopes 0A- • Spot Elevations p11� • Permanent Erosion Control Measures (drop structures, riprap, lining) Tie-in to Storm Lines, Pans, Curbs, or other appurtenances �� • Required Minimum Freeboard, Provided Freeboard Ok Landscaping Infringement on Flow Line? 3. Pipes plc Size and Type C7� • Slopes (As -Built and comparison to 0.4% Minimum) Vlg ok N/0 dk • VIA N1q Pipe Capacity Calculations (if slopes are significantly altered from design) Invert Elevations Installation and Backfill Cover Encasement and Clearance from other nearby utility lines Joints Type and construction 2 C 'G 016 4. Concrete Pan Channels p6aKPjL' vcEr�artY �qu.2ere • Size • Slope • Cross Section • Thickness • Elevations 5. Inlets 0 is • Size and Type Ou • Size of Opening (or name of Standard Detail used) OK • Grate Elevation pW • Invert Elevation p% • Box Size tj A 6. Street Cross -Pans �yttl��� • Size • Type • Grade • Elevations • Cross -Sectional Depth • Tie-in to Curb and Gutter 3 Crty FtColtins CAG VII� 7. Culverts • Size • Type • Invert Elevations • Headwalls or Wing Walls KIJA 8. Sub -Drains • Size • Type (Perforated/Solid) • Cover • Backfill • Geo-Textile Liners • Clean -Outs 9, Curb Cuts 0k • Size Gk Tie-in to Swale, Pipe or other appurtenances (� B. Certification of Grade Elevations Adjacent to Drainage Facilities: • Minimum Opening Elevations • Top of foundation Elevations • Comparison to 100-year Water Service Elevations • Comparison to Freeboard Elevations and Base Floodplain Elevations —BFE a C G 1mot` �Collins C. Certification of Erosion Control Measures: �f 1. Permanent BMP Measures: 6)C • Permanent Vegetation (no more than 6" bare spots and weeds under control) �� f/� • Riprap or alternative permanent erosion material i� � �,5 `� A1161 • Riprap Bedding Cut -Off Walls or Channel Drop Structures Cross -Sections Sediment Basins VIA • Water quality ponds/Sand Filter/Bio Retention Construction and liners NIA • Permanent Netting Mats or Blankets pk • Mulching and Seeding 2. Temporary BMP Measures: Oh • Mulching and Seeding c, ,_ • Temporary BMP Measures as shown on Erosion Control Plan D. Post -Construction Site Cleanup: o(_ • Construction Debris Clean -Up C,�_ • Smoothing of Ruts in all Construction Areas V k • Reseeding of all Areas Affected by Construction Activities 5 GF� City of Fort Collins ^ N'►— E. Statement of Compliance: This certification is signed and stamped and by signing this form the Engineer(s) attests that they have inspected the site and to the best of their knowledge the as -built conditions of the drainage facilities are as described in the above form and in the As -Built plans enclosed. Failure to properly disclose all known information could result in the rejection of this certification and prevent the release of any and all Stormwater Utility permit holds on Building Permits and/or Certificates of Occupancy within this development. F. Signature and Stamp by a Colorado Registered Professional Engineer 5 7i 4N F • � r# r 1 A t uppr x 1 7�.., � Y {fit {�,•.. 1 r � • A •,�1 ft 1 �^ ` r. 33• / . �i r 1 .. C Lis- .• 1� s♦ • f� < + 1 r ��`1 - .ct IC 1•..i9 s.. F.a., tl *'.{ r11 , � ♦ ♦ �,: f i • ;�.� - A),. J!./ 'L_; -� _ '1, / ��.dY t• �' ! �- `j '�h i l� � � t 3ii���2��V���rA���'� . .•�Y� C. � S � TTTSdd ,pL 7•, i. rr l I 6 MCSM iW CONTROL c ,NMI N K r.J I'll IntT .w wA,n MITx9 WIR C.a s M rbexr mwn pow, Y. xxx a.s ..✓ a r ecru Nu a¢N vu ann ar°Ev m.20•m»i[. EYN90.V fMrn0. YUNtENW¢ R WC 0.9MSB611v ar Tq aYCaYK ■ HANDICAP VBBBCLE TRACKINO CONTIIOL PAD CONNRILUCIfON BNW9Ux NO: I MINION aATN: O9/Ol/Ni CLASS C BEDDING e..M 70.,...1. Y.e..r. UNSTABLE SUBGRADE y r+ ma nU e.ws.9 renwa xmw 1. I a wlxe wn1 a w W»In» eMpw 1 h - Wlelee Plpe Olmmely. x RNM9 Ye e I rw°' geao ae. _ m WIN Aft-, SUBORAIN DETAIL BEDDING REQUIREMENTS Ir rY Y NN mL,ST n' f+llf5/[rnras _ I 1 _ w.Wq`rr rn .Wkw»o�e .pp,M e' xu. mm wpw r u✓rv."Iw ,... 7,37 m..I.I.eW. .. ! r _ vYICs ill '� - - �+• PoLEI' :: Cmnel. STANDARD e'[urolmxop9 TYPICAL RAMP CROSS-SECTION 12" ADS DRAIN BASIN AND COVER phn NYEOPLAST 12" CRATES/COVERS MID -BLOCK PEIIESTRIM RAMP DETAIL qE xebe ,MeeYe en. II wa �be�,�1? � za � ? r+- ,• 2- C0hp Q ANNEL J- - SIDEWALK ..,, N.T.S. �,'a'� 1 IJ- OU TFALL N GUTTER ' a • N' FOR USESE ON SITE ONLY T N.T.S. aM CP[NKrG N.IC P'". .Vol JaW eyrr ARIFs t•" (10I rmt. r rm ssC °1-x' 2' CONCRETE PAN r<- ' R N.T.S. , Iryv s e „rsW . ' r INFLOW L a A/• YYr n' NFLOW CURB AND CUTTER FOR USE ON SITE ONLY Note: Joint droll be a, N. T.S, CAA ,bloxneee of CURB OPENING DETAIL ` f`i^Illmly N.T.S. CUMMY JOINT FOR WALKS ON -SIT- CURB AND N.T.S. GUTTER DETAILS rM.wN wen eeYebYe A 1 wsr�Ysu -' I T aLvxuxm rus nr _ � ,R' mM.TI.e w sm epv ro xATcx ml r ., CnW WWee [xlsnxv n.PA[v wv. wen rI"Pp. n IAYxm1M M �J waseen r 1. vwur *+� aK1.�. 9.MIYN P°..e w . rl 1.1' nY -L I C -/ GNnlri a 91oInNe S,W Ghal wW1 Cmvne MWMve Cmrnee m r.b,K H— Iq me s4ruelun igxp b;T5pw an (W.I WATER QUALITY WEIR AND BAR SKIMMER WE® PLATE r CN -n CURB. GUTTER { m qm • •'' .— . e.X,b Yw.. AND my p W ,3 4 � ATTACHED SIOEMAI Y DFTAII Oe C 5 k THICKENED ASPHALT �•L Qa m � P.C. P.0 1MKDffNED ASPIMLT WEAKENED PIMIE JOINT JOI IXPANSIDN JOINT SIDEWALK DETAIL MOM:. c°nm MON Nrns°n DNATImc .e�IwNWrOM:. -yumm M 61/OR/I,I IRn9 SF St«I n F.,n FPenc WPOE psi vppl"- -.. SECTION NEW 2 N mIe rgpr I n Q.n w1. R.ee•r .RF�.II .I,» war er u. e.pl a IW r«. nw eW, MN Remeb.e »gmenl MMI T . THICKNESS OF CROSSPAN W . WIDTH OF CROSSPAN m THCKRESSS _ "UW I _ SW l iNCKNE55 p In I SILT FENCE I ASPHALT PAVING DETAIL me coxBrmrnox � DBMIalC9 W U a J a J a J a � w a O m W Z O CRy of Fort Collins. Colorado UTILITY PLAN APPROVAL APPROVEO: NECKED BY SHEET wn. A xvlewl. unxv °e1. CHECKED �'1 ilwmml. uIYIIY Oale v CHECKED BY: Pvn M Rwp11m °n1e CHECKED BY: B OF 8 'a 223-t)Ii CHECKED BY. - V • Glen Schlueter From: Brett Brown <bbrown@dohnconstruction.com> Sent: Thursday, December 05, 2013 4:51 PM To: 'Michael Palizzi; Jay Barber Cc: 'Cody Geisendorfer'; Glen Schlueter Subject: RE: One Boardwalk Place Certification Jay, the three permit numbers for this project are B1206691, B1206715, & B1206708. If you could please let me know when you have released these I will be able to come get the CO's. Thanks for the help! Brett Brett Brown, LEED AP, CPC Director of Field Operations Dohn Construction, Inc. 970-490-1855 (CO) 307-634-6177 (WY) 970-490-6093fax bbrown@dohnconstruction.com Please consider the environment before printing my email From: Michael Palizzi [mailto:michaelCa>ciuuality-enciineering.coml Sent: Thursday, December 05, 2013 4:02 PM To: jbarber@)fcgov.com Cc: Cody Geisendorfer; gschlueter@fcgov.com; Brett Brown (bbrown@dohnconstruction.com) Subject: One Boardwalk Place Certification Jay, Attached is the certification for: One Boardwalk Place 5223 Boardwalk Drive Fort Collins, CO 80525 All outstanding items have been taken care of for this site, including the outlet structure modification (see attached picture). Please let me know if you have any questions. All the best, Michael Palizzi Engineering Intern Quality Engineering, LLC Civil and Structural Engineering 1501 Academy Court, Suite 201 It w ps 1 f.e EMSING PAS TO MAA,PI. [OX �EWAu .EyR.I. l BOARDWALK DR msTNc _ — _ — _ SDEPAIM TO C t{--O.--7 — - - -71AS Bv' I , j - - - — f--- - ------- - TRACT C I 1 1 I 1 1 I I I I 1 I I I 20 10 0 20 SCALE: 1' IN 20' 1 REiDI 10 DEVOE'. P.AN Eq ASwNT PEYW4. MT TO STRAW q[µ ECQ, I. OONTNCTYI IH. BE RESPOKSM !OR THE REftA3YExT Cf µr ONVAGE3 EDAD e WTTV 3 AL WE.4Y5 ND W., S141 Y CONCRETE I 4L SAE.AIXS .. NAVE A YAAWA EAOSSE $LOPE OF M ! A A.. SLOPE W T$ 04[1RI --WL OF 5010N.ESS -OTC O'ME-.W W ANT AREA MAT ME SLME N T E DRECTM 0P WAq "OVEDS S. a ME .1% IS YCIE THAN S'. NANORAR5 ARE R WKD S. PINW 01ME AT ME FOUNDATION 0- ALL EVIDN05 MAL- VE A WNYLM TE OF 6- MO. TIINSVE] RDA AFTER ALL IYO..G IS NST4LED. C FW19TD GAGE STALL FA'J A KNYIY OF L- N ME F%T 1V AYAT IN. THE IDINDATpx IML 4lED ALL. LµDSCATNG S NITAI 11 t. THE REM WALL K ALL. WAGE NISANGS SPILL MACS A FOILDATG TO AN EEEVATON V ABOK TE EILVATONS S-OM. 6 REFER TO SECTON ] ,1 OF TK LAND DOE 000E FOR N101LASE USES NMN ME PLAT IAL -.ADTAT W R LWE. FT `TWANEO FLOOR pROPERtt BDNIOAflY TO MANNED CDOE — — NGT-Cf-NAY It ROEVIE---------- ADJACENT PROPERTY LIKE MP NIGH POINT — EASEMENT LINE JI LOW POINT EYSTNL I- GCxTWN4 W ORAOE DREAA IDIO EMTNG S CONTOURS EM ED42 OF A0,P41 PAE, [D I. CWiWRS ECC EqT OF COPCMTE DID— PROPOSED V OOHTWRS TW TOP OF ASRMLT _... _..._..._..._ PWVC6E0 Rawl* TCC TOP V COPPONTIL — PK)AMED IWLO. CMD Ts iW51ED GAOE AT .—. PRD+OYO RNl TM 0, INAL1 ... ..— W DONS 0. PNI I EVENED IT IT PREO Y PoNom 'AN E "TTLW OF MAIL PRyD3D DRAINAGE PIPE RI. TIP OF .ALA ETS•Y1L GYNAQ PIPE TOP TOP LP PpM MPP P On, GARAR nws.ED FLDG WOG oa35m 0 E ti� �Nmm d 8`r� ^tea r3au -r a 0 w U Q J IL Y z J Q a Z � z Q 0 m w z 0 City of Fort Collins. Colorado UTILITY PLAN APPROVAL APPROVED:_[^.�'�A CHECKED BY: AE�E� --=T ND:w e a Ts Dc" C CHECKED BY: CENTER OF COLOR' 1.800.922.1987 mN..EN uL ✓ 5 E{y x-ausxESE DAYS Ix NpvAvtt CHECKED BY: A/ q DIN a N,..I"A . MORE YCI ING. GADG ON EICAVAR FM ME K."N' OP S OF 8 MRDENGUND PANDER UTJTM CHECKED BY: NA. T FnRL+m D. CHECKED BY: a 1 �d-li 111. Job ND. 223—OS C3i.hr,:Z„O A? BOARDWALK DRIVE I = 0 0 o �I-:U:-r; 1'- o 0 0 P0Qa CC[CO I• COVPLEX c IT ''0't / _ v I—= `.I c;w,1r T V U �1 m f., .,+. t ,n l v v I neon cakAu oexat o n n n � . s �— •ft I n FF = 71.28' Ya rtN �.1 FT = 7a.C5' w osa GARAGE �- fi loz r m D D C m z C m 40 NOTES: 1) AS —BUILT SURVEY POINTS PROVIDED V BY WASHBURN LAND SURVEYING AS Z PERFORMED ON 08/22/13. Q� 2) ALL FINISHED FLOOR ELEVATIONS } w ARE APPROXIMATE. ~ z a (� dW SYMBOL LEGEND K GHI-�F-WAYj' P '! �P=(-I-Y LIVU_ EASEMENT _It\E H D JLDiNG LOT p m SIDEWALI f3Wl DING EXISTING 12" PVC STORM (iYP) � Z b" ?VC STORM 0 h � AS -BUILT EI=VATIUN � 12"x12" ARE' E'R" N — —� NO2 TF/ G -20 n 2 0 HECKED: CAG DESIGNED: MAP DRAWN: MAP DATE: 09/26/13 SCALE: AS NOTED PROJM: 1034-028 EX.1 _ _— _ — — D6sexc 9NrrARr YMR YAHIpE Ap msr-c sNeTAm R KBER YM1IM) eln •D■ LAxE No T vARrJNc avl I EASHI G I' WRB STOP + NAM Ca".0 2A' IRRA, FT TO REV.. k K USED ADS MAIN rw BVGAPM mll FT AM BABY (M) NET I'ELP VERNw. HI IS iADPINO _ SADDLE + Lrore1ECT ro WSIFG TEAM VAN "STAG 12' 'IAF lA1E Np PW m VATE(Tw) PIJIXFP ARON L slaw (M) vw ¢ECTWCA! nANSMUEl TO IB]LAN PROPOSED ASTING MAIN INSTALL SB.B IsN Ir. �� M BASIN TS' dAN IwOlA1K 6Na MAXrB011 rA1EA SERVICE. ASSIBBTO vs TO nap I oa■o I I I ERwG rn I x n6AMT m I 6[YW (M) vnS MAP., MANNpE OI MLL•wMLTp AIMIST BIM 10 NEIN Il I f J IN, A- 5 43 L _ FV WT.wyLl] SEANCE WV.w56U INSTAL - AD BEND I I P6WpaD r/TB I MNLFG I I I I I I I I MT41 10.s W n' PK I i AT ti DL I I L CONNFIT i0 EASING I yMTARr WM sFIiNM. J MST. r Ih'C A5' BE10. r - 1 MV.SA9S91 I WALL N•BRINSMALL 9N9A I MArz•699 I I 1.E. �liJ e�• PK ETKB r OOb0 I 1aB9 _J SEND.[ IDEB NG ORMA III INSTALL WN• TEE EAsmcELECK PANEL T PAM4 O BE R0.1pVm I I I I I I BOARDWALK DR -el Ep5Tx0 F.gtlG 0.J r. sps NsrAL! :.• orAM eAMx EMSTNC YANNO.E W C951WG 11' S1p81 COINED% PONr PRa'am slap MML ro ROAAW wo rATa f1mTIND wrz.Nl r. FLLV• 32 NM/1 i!1l�ao oll ___________________r_ _ A; - a _ EPSTING mall. ON 9• MIT,," } LL(LpIT IFINK LAIR NO „ x ,. •A I I PARKING' SON _ •`• L EXISTING HATER q rAF fTwl I 1 f_______ J L______ Col DOWN r — l BASIN TO w w ' I I wArz•nD I I c0 ct To CYSnNG PROPOSE SAYTMY S SERVICE WAIVING I EASMIC 12' I INY•ineN.l I PW MMA2 j I a I SifAY (M) I I "ITALL vNc AT IB AT Is aME 1 SA o I o INSTALL 5,.1 lF EX6TMG p1AM INSTALL B' IS' BONG II B• p4, BARN 10 IFMAN _ I O BN• 059's INSTAL IS LNe n' INSTALL B' l5-BEND iNV.4m 6 0 Ir1ME YRMC[. pLAR•n8) IE I PK AT is SLOPE IPRyosTO cuss STOP A, AJ.a V e' PW Il.i LETER NI 't 4 CRW EME LNIE A,IAbTlib m [ lule9R I PROPOSED CIMB STOP + L _-_- - Is'ACTED FT NII1079.!! E JIMB41.E3 "STALL vs LIP TV Ill ` SAM SERVICE. lwS I.5 TAPFNp CONAEM TO FASTING WAITED ENSIWO SINE CpMECT TO E Wiii WA10r1E X ACMNECT W EASING A XSOl41r ro REYAF MSr4E Ya TAPPNf SAKE 4ME r 6 un2 VALVE SAL W vANMX: _ _ ro EASING BATTER Y.W. 86r111 WAS, TMNNO SW 55 SS _ _ BABBLE WI 6- WEE SAS ss �COMECT VALVE S 293 IP a- Pvc LRE �OR 7 PANEL (M)) 5EE NOTE 6 ll.s 9 5C f TC CPW I COMECT ro LASTING WARN MAX. INSTALL Ill V PVNNG DAPPLEM/m. 6' WTE VALVE K I 11j EW1N0 J Ells LINE t L I � EA5,6NG B,Aa,ARY „AIxNM.E 1 Tyy ( I ( I n iNN•wtpap I 1A.1 LP e' PM: ( ApYST 6w ro MEIN ELEv 'FES LANE NO I NV wT.AeSB.M /) I L5O0 NE IME P6EppgO SERVICE WVNMSS.M �V PAR[NC SON I I BATTYE 25.3 LP AT OIR R PK AT I;SLOPE 1 \ � r---- / I 1 �\ _ _________ J �/ MT4Lr w' T - N L _ -Sjy eENO r/ 19 E1N51K MM.WN CMNNEE, ro EL5TNG l ®q \ PMMOSD UTLITY Is B�/ WBa'Z ws TPNI MsSALLTM POSE II,ES' AND. \ ""IRA: AC(E4 Nv.f F559.a (NDw / 1 ALT TO MID walllr vw6Es) I mTvr ul Lr e' Iza Lrr I PK slOwai Plc sT 4 zW Imp PROPOSED I I MMOFD XAApW Og00 OAMPEPWAR ,OA r I D I AMONG slp (TV) I 1 6UEOM6 1 INSTALL li' Osl 1 J L________.T______J I BOA91M�/IM BAD YGTA 11' MAN MAs.WG Wy.Syyy wTE.69W MATE.se.6 1 I I I I I I I I • LINER GAATE fRCY n,W Tp E➢9p I dl I < HAV CGIII6M..0 I ELEV•wnll M IIJpe1.50 F Al]551.0.1 hEPSDN'T PRIVATE 51Cb1 I DOSS �I I u-. I' I II { I 1 I P II 1'r III NADNAL NANWi [PST A) MAIN V r.9rE61ME (SAE DMINTOIR L PRIVATE �____==_1NOIO12- BfIC __= 1 xorz a) slaw ( ) M I \ ' , . __ :`"EI,_ 6 EABVN' ORMa Y9N rO NAW" ws•99.! ____ 7� IYAr PlC TEE 1 iI 9LV� i 69n16 � iI �mm c omm C HE b �C 20 10 C 2@ - '5O:mn dO � fA < n c SCALE 1•.20' .. w g`g ti� n34LL 2� r a CALL UTILITY NOTIFICATION CENTER OF COLORADO 1.800.922-1987 S 1-BIHNNI 5 DAYS N ADVANCE 0 I YFME YW IM MAX EM MAVATE IM THE VAMLING Of LwLRaoIMD UI 5 "TEAM un-,X5. IX "TES I IxllTS M ASPX4T CVT Affi APPROPRIATE. rM4 Mn ARE EO BE DEMIWNEO IN PE FIEU BY THE CMSTRYCTNYI MANAGER. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH OFT STREET REPMR STANDARDS d Z 2 ANY &OEAALX. H NwT[R AND ASTIKT p4LAFM DOMINO CONSANCT SXALL BE TO TR rgti N COU116 Siu0AR0 AT ME ERPLTIS pF M CpxTRAC1M, f EVEN n CO n O PROPOSED %AM SERMM SMALL K N.5' OIANEIER ME A COPPER ry 0. 4 m IN CMFORAMCE MTH ME OTY OF FMT COWNS REWREMp115. h R A PROPOSED RAM SERMEE 4ALL BE V MAYEM PM.' DHSS AT ♦ � •' MNMN M Ix SAME IN [OFMu vCE IIITH THE OTY OF EMT 1' E EOLITHS R.MfRENxTS 5 5. 41 HATER TINES TD MN A5' MINiMM ANDMO 5.5' NAPYL4 a P n OP FRO euRY OE^M TO TM M MNN rRM1 TMISNEo M0.M0. m a C 6. CASTING G. MANGER. EPlINC ws LINES KRE NET LOCAR3 ON v O SITE O YI O p T. EASDNG ELECTNC4 PAND. TO BE REAR L Ml RU-MATE.. B Ill TO SE"M l.A 1 M ttE LAND USE CM£ FM ALLORABLE VIES AI NIN THE NANRK HAD TAT BI1FiEF ZM �j..... . Ill ¢wm ENO SECBDN _ WwpiRTY -"-Y ■ MANIJY rtlEl _ _ PQHT-M-.AY NO AlONAN AIwcLYl wpvERTr VINE W SERVICE OEAKOL" — EASEMENT IME Q ERE NTMAHT EXISTING RACE 13 YAM METER IT -------- - -I.PI IT. A CLAN sTM .. EPSIwG PHALT ® NRIGTM V4V, EOSNIG CANNAW PIPE I . 1 AH AVANATCN VALVE VIS1.0 SWTAAY BEATER/ 1� ® ¢R'FC SERVL£ EPSMF YAm YAM VL ® ELECHAC 10.E — As — — — — FASTEN. 99pci'M YUN !Y LNMT POST FASTING ELECTRIC MAIN /l\J ly p "NOR UONT T Ell SAE AOVE Al. i Z ■ AC uwT A — — — — E"HVP GA6 MAN J o whin POE — TP — — — ENsnNG PROM ncS MAN Q M TURPHINE MEsrK ET - - EPSTING CABLE TV MAIN 2 a A Ws NEM PRMOSEO STORM SEAR I us NMNER ///•/ cl iRWSn RANT. SEAS J [B FI4R CFTC YAWI MWpgD WAM NAN 0 CARTE TV PELESIAL tlh PROMISED ELECTRIC uxc O + BM POST m.E "c"351D TELEPHONE LIVE S rE¢ P,PJ ..E PNOPONAp GAD LNE m W Z O City of Fort Collins, C-Iorldo UTILITY PLAN APPROVAL APPROVED 6p1 tN SHEET CHECKED BY: r.l •eN uoltr DOA CHECKED BY: A3 , / /3 SNam.vlA DM.Nr CHECKED BY: N.w P.. + R. P..., ENT. CHECKED BY N—__l 4 OF 8 M1eTM1A1 1�IR Nell. CHECKED BY: Joe N.. ttl Dale 223_05 v f W omdc ME tl(Fi 11f - -- _ - -- - -- - � _ _ _ _ _ TWARDWIWC ORRIS 1 CIP-3r Emma ME CALL UTILITY NOTIFICATION CENTER OF COLORADO 1.800.922.1987 CE BEFORE ]D An IN EM pGMADE. M E.UVATE EM NE YIMdG M VAXRW.RD YEAM UrIUTES I I I 20 10 0 20 W3 — SCALE: T' + 2U' --------- ------------------- 1 .1 DRAINA 9 A EROSION OONTROL LOEIO k.' Q1 DEscn rant IV I e.vT a B-m RUNMF 0DEFnodT CIP-3 „ ',' FLOW NAECTOA I 1 1 BBSIN BWNDMr --- Emma AM 1 I IRMOSED STORY PPE 1 .°OS Ep5d0 Y Cd'WII T i) EVS1.01' CdimR �i1 I i I 1 �rm5— rRMO5E0 >'CdTWP 1 I MaPos 0 1' CC .R _.YtD ®—SF—SF— 911 FENa _ _ _ N P SF I I ® W. CUE 1R.Q4MG CdMa PAD _ _, II. I I ® EJ gNatETE w/.T ME. M O1 � wt l® w.T1L' I I I wS I I w.rnE e I `I I < I clva ��p INT,ET rflorzcnd CIP-3 1' 1jJ LATTER PROTECtM 9 ' I I I � V. aEOE-Ay wl.rilZ R>-W 1 I I IF w' I I GENERAL NOTES 1� ' I T. SEE LANDSCAPE PUN FOR PLANTINGS 1HRWGMWT NE SHE. it -1 EA SF 2. NO IMPROVEMENTS TO BOARDWALK DRIVE OR SOUTH LEMAY CIP- 1i AVENUE ARE PROPOSED. x1 3. THIS PROJECT INCLUDES MODIFICATION OF THE EXISTING CUTLET STRUCTURE LOCATED IN THE MIRAMONT DETENTION PONO IN I 1 j ORDER TO PROVIDE EXTENDED WATER OUAUTY DETENTION FOR I I N 1 THIS SITE AND THE MIRAYONT DEVELOPMENT. REFER TO DETAIL I I SHEET FOR A DETAIL OF THE PROPOSED WTIET STRUCTURE MODIFICATION. O I * I A REFER TO SHEET 2 FOR EROSION CONTROL NOTES. 41 >; tr S. REFER TO I I SE3.4A OF THE USE CBFOR ALLOWABLE USES "THINTHE NATURAL HABITAT BUFFER ZONE. IP-3 I F I w U Q J a Y a J -E Q a- LLJ � a cr z Q 0 m w z 0 City of Fort Collins, Colorado UTILITY PLAN APPROVAL APRROYEO-�� CHECKED BY: LI/F •-1: wRm a .�' u.md unrey oP<. CHECKED S:orm.e:x OHRy Ool. lJ CHECKED BY: Pay l flecnalim pal. CHECKED BY: N✓f 6 OF 8 Tm CnYPP ^ D014 CHECKED BY: NO-13 Jo0 NO. 223-05