Loading...
HomeMy WebLinkAboutLot Certifications - 10/09/2006AMES ASSOCIATES October 9, 2006 Mr. Jay Barber City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, Colorado 80521 Re: Drainage Certification for Lesher Junior High Dear Jay, We recently surveyed the Lesher Junior High additions located at 14000 Stover Street in Fort Collins. Spot elevations were checked. to verify that the approved elevations and drainage patterns were constructed. The enclosed 24" x 36" drawing shows surveyed spot elevations. Observations taken during the site visit in combination with the attached as -built elevation verify the flow directions indicated by the spot elevations on the 24" x 36" drawing. Visually the site appears to be graded appropriately to ensure surface water drainage away from the building and towards the designated outfall. A 30' by 70' concrete pad approved as part of the project was not constructed and was replaced by sod and landscaping. The installed landscaping maintains a positive slope away from the newly constructed addition and also adheres to the approved drainage patterns. A positive slope is maintained at all locations around the building protecting it from surface drainage. It is my recommendation that the Certificate of Occupancy for this property be released. If you have any questions, please call. Sincerely, Ayres Asso ' t c ric P. Lessard, PE Project Manager EPL:sp Enclosure O .p01.d;ST �. LS F o.' Nq .•p 7 62 Engineers/Scientists/Surveyors 3GG5 it-K Parkway, Building 2. Suite 200, Fort Collins, CO E0525-3152 (970) 223-5556. FAX (970) 223-5578 www.AyresAssociates.com BARBIOU DOC 3-1012.00 "k l�%/� - to o6 cats (e im--w - - -Jav" City of Fort Collins Utilities electric Y stormwater • wastewater • water Date: September 8, 2006 Permit Application No. Address: 1400 Stover St. Lesher Junior High School Track A University Acres 1st CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) (,(Print) 02-'c-- LZ-6s-O , a Colorado registered professional engineer, have personally inspected the above referenced property in the City of Fort Collins, Colorado, and verify that construction of all stormwater facilities and grading there is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on 9-30-06, accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot as measured are in general conformance with the City approved drainage plan or revised grading plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainage plan. SEE NOTE. p0 R`Edi. �� ' DES ' •TF By: •q -p (signature, PE stamp) co (address of signing parto NOTE: /�yq�ENG A COMPLETE certification m ad, including but not limited to drawings of the Iottsite showing the approved design or revised design and as -built surveyed elevations of all structures and drainage and grading features (e.g. swales, retaining walls, lot corners), written informationtexplanation of discrepancies, etc. to: Fort Collins Utilities (970) 221-6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property City of Fort Collins Utilities electric • stormwater • wastewater • water CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 1/5/O� Permit Application No. Address: HVO 5v v,div 2 y� Lot: Block: Subdivision: Jr 4l (,(Print) ?5--: & t , a Colorado registered professional engineer, have personally inspected the above referenced property in the City of Fort Collins, Colorado, and verify that construction of all stormwater facilities and grading there is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) b accurately and truly depict the elevations and drainage patterns as they existed the date of the survey. Based on this information, I certify that (check one): VThe elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot as measured are in general conformance with the City approved drainage plan or revised grading plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainage plan. SEE NOTE. a (signature, PE stamp) (address of signing party) NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lottsite showing the approved design or revised design and as -built surveyed elevations of all structures and drainage and grading features (e.g. swales, retaining walls, lot corners), written information/explanation of discrepancies, etc. to: Fort Collins Utilities (970) 221.6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property ® NORTH m_w C,mIF flPY R.P /Ka�RE cWigN Y H OG V F 2 N V) � L9 L 10.i K ti Ste`, 02�N�gFg S O O z Y c� 11J ¢�ar'�i � w�rY