Loading...
HomeMy WebLinkAboutLot Certifications - 03/29/2012or�AQVANCEQ ENGINEERING, LLC STRUCTURAL DRAINAGE DRAFTING OVERLOT GRADING OBSERVATION Site Observation -Date: Site Observation by: _ Site Address: _ MJ-4 H Site Legal: Lox 1, I -am Site Plan and/or Grading Plan by: We have observed portions of the above referenced site. During our observations our representative measured the relative elevations at the lot sides and comers, top of foundation, and lowest openings. The observed elevations were compared to the Site Plan and/or Grading Plan referenced above. Based upon our findings it is our opinion that: It The elevations as measured are in general conformance with the above noted Site Plan and/or Grading Plan The elevations as measured are in general conformance with the above noted Site Plan and/or Grading Plan with the It is our opinion these exceptions, as noted above, should not adversely change the grading scheme as shown on the above referenced plan. During our observations our representative noted that the as measured elevations do not conform to those indicated on the above referenced Site Plan and/or Grading Plan. However, it is our opinion the grades as measured should provide an adequate substitute to the above referenced grading scheme (see comments below). Of Seethe attached "As-Builf 'grading plan. The elevations measured are not in conformance to the above referenced Site Plan and/or Grading Plan. Deficiencies include: Other comments and/or observations: Limitations: It is our opinion the above referenced site, as graded on the observation date, should not interfere with offsite flows unless the grades are changed or barriers are created such as fences, garden terracing, sidewalks, and/or any landscaping which may change the established flow patterns by diverting or slowing runoff flow. Backfill adjacent to the residence may settle over time, this settlement may allowpondmg to occur adjacent to the foundation walls. To prevent this ponding and related problems, the baclfill adjacent to the residence must be monitored and maintained to ensure that runoff will flow away from the foundation. The grades measured were compared only to there ' wn on the above referenced site plan and/or grading plan. Other minimum grading requirements which may be iRth port or by other construction documents are beyond the scope of this report Q` .N.E.7 33739 Reviewed by: Jason E. Baker, P.E. NA'L 146 Barberry Place, Loveland, Colorado 8 3 ! Telephone 970-278-1909 Fax 970-278-1910 'AS -BUILT' OVERLOT �s GRADING OBSERVATIONS 0 562 5l2 54.4 / 552 53.9 WA D 553 54.4 J WA559 TOF..560 TOFF. • 51D 54b k \ 55A •� k H.P. 55.2 TBM-1 Bob (B.011l.) 55.1 •. DRIVE ... B DOOR ,� 51.9 559 DDOOOR 551 Ff�tcPa 55.5 1 W.W. 52b 552 k 54-2 ID 53.1 1 BOA LEGEND: T.O.F.- TOP OF FOUNDATION W.W. • TOP OF WINDOW WELL D.W. • DOOR WELL B.O.W. - BACK OF SIDEWALK B.O.CAG. R BACK OF CURB 4 GUTTER T$P1.-I • TEMPORARY BENCHMARK I H.P. • HIGH POINT OF SWALE ®. SEE ADVANCED LETTER 11'11-01-02E DATED 3/20/12 PRnrecr nvlm�, 1111"01"02E - ADVANCED . Luxury Homes of N. CO DAM 3/20/12 Lot 1, Lemay Avenue Estates, Ft. Collins, CO ENGINEERING, LLC 1sr•"30' STRUCTURAL DRAINAGE DRAFTING Gc1'1 I f 146 BARBERRY FL K. LOVELANO, COLO"00 90937 I OP TELEPHONE 970-278-1909 No Text