Loading...
HomeMy WebLinkAboutLot Certifications - 08/01/2007 (18)!! of Fort Collins Utilities electric • stormwater .wastewater .water CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 7-24.-07 Permit Application No. A4k?yla Address: 2738 f:�Y Lot:. S Subdivision: L I r (, (Print) verify that the above Block: 3 a Colorado registered professional engineer, property in the City of Fort Collins. Colorado, has been inspected and verify construction of all stormwater facilities and grading is complete, and the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) 1- (3-0"7 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot as measured are in general conformance with the City approved drainage plan or revised grading plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainage plan. SEE NOTE. signature, E sta' 27 t 165 South Union Blvd.' {•az 156 .' Lakewood, Colorado 80 (address of signing NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design or revised design and as -built surveyed elevations of all structures and drainage and grading features (e.g. swales, retaining walls, lot corners), written information/explanation of discrepancies, etc. to: Fort Collins Utilities (970) 221.6700 700 Wood Street Fort Collins, CO 80621 Rev. 12-08-05 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property IMPROVEMENT SURVEY PLAT AND �\ Carroll Lange DRAINAGE CERTIFICATE SCALE: 1" = 20' Professional Engineers & Land Surveyors 165SV 4V Lakewood, \ / South odolvo., Suite 156 JOB N0: oUnion n B80228 (303) 980_0200 DRAWN BY: PH DATE DRAWN:5-25-07 TRACT "A" LS#37053 38.50' N00 00'00"E lv LS#37053 d LOT R1 BLOCK 3- 03 } x gy�pp,� Atw o! 3 24.0' GF•=29� 0 2-STbRY FRAME 0 O 2738 PORT PL. +' o o f(' cp �I I L� FG31° 24.0' fjA"A78' COVV rV 9'DE&UE 38.50' N00 00'00"E No FUeow FO W a PORT PLACE IL REVISED ISP: REVISED ISP: REGRADE: _ LEGEND • =FOUND #5 REBAR WITH PLASTIC CAP O =FOUND NAIL & DISK E=PROPERTY LINE BOW=BACK OF WALK BOC=BACK OF CURB FOW=FRONT OF WALK IE=FLOW LINE I] =PEDESTAL T =SERVICE *=LIGHT POLE V=FIRE HYDRANT PROPOSED TOF= 29.8 AS -BUILT TOF= 29.8 BEARINGS ARE BASED ON THE EAST LINE OF LOT 5 BLOCK 3 ,OF THE RECORDED PLAT LIND PROPERTY FILING NO. 1 BEARING N00'00'00"E WITH MONUMENTS AS SHOWN HEREON. THIS CERTIFIES THAT THE ABOVE IS A TRUE AND CORRECT PLAT OF A SURVEY MADE UNDER MY SUPERVISION THIS 23RD DAY OF MAY 12007 OF THE PROPERTY DESCRIBED AS: LOT 5, BLOCK 3, FLOOD INFORMATION: LIND PROPERTY FILING NO. 1 BASED UPON REVIEW OF FLOOD INSURANCE RATE MAP COMMUNITY CITY OF FORT COLLINS PANEL NO 080101 0164, MAP REVISED MAR. 18TH, 1986. PANEL 164 OF 278, LIND PROPERTY LIES WITHIN ZONE "C" AREA OF COUNTY OF LARIMER MINIMAL FLOODING. STATE OF COLORADO AND THAT THE LOCATION AND DIMEN,509- t F, ALL., BUILDING IMPROVEMENTS, EASEMENTS OR RIGHq§-OF-WAY IN EVIDENCE OR KNOWN TO ME AND , 81Ffk(EKTS�B,Y OR ON THE PREMISES A ACCURATELY SHOWN. \... un I ATTEST THAT TO THE BEST F MY K WL ' •�'+ !(, n /%////�OJ AS —BUILT GRADING CONDI NS COj��,.// BY:\�'sfFi—f DRAINAGE INTENT OF THE AP OVE�ARYA 012 t1�:j. f BY: 28127 + DATE: DATE: -19 07 s R s .�. 'fir RECERTIFIED BY: DATE THIS SURVEY DOES NOT ADDRESS EASEMENTS OTHEP%',�FIQ�$II� o- E RECORDED PLAT NOTED HEREON. NO TITLE COMMITMENT .WAS PROVIDED TO THE SURVEYOR. ::.. NOTICE. ACCORDING TO COLOItADO LAW YpU MUST COMYENCEANRON BASED UPON ANY DEFECT IN THIS SURVEY N1 T111N"THREE ,YEARS%AiTFR YOU FIRST DISCOVERED SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF THE CERTIFICATION SHOWN HEREON. 47 �j 0 9 V H r� 1 I II co ro it CN co Ll- U� Lo c'k C-0 - Loo. 0 C4 �co 6 30 t, 04 LQ (10 C' 0 Cri it It to (CMD� Ike\�\�„__ drill a! `` , � � -/ '•�i•F•:f + %6 00 C4 C-4 II Co. In re) It It u- ry LL v + + JlQ)R(- + 96 lc� ro 0 LL r5o +4&,GG— -"O:g ��' 0 tl,9— HI wi\l�ULIING INC. SANITARY SEWER INVERT NOTES: TG8 ELEV-- HUB GENERAL NOTE HUB i. THIS PLOT PLAN DOES NOT SHOW LOCATION OF WINDOW WELLS. FOP THEIR LOCATION SEE TCB= 28.1 ELEV t EUEV— STRUCTURAL ENGINEERED PLANS. 2 THIS PLOT PLAN IS BASED ON INFORMATION PROVIDED TO CARROLL & LANGE BY THE BSIVIT HT= 10.0 HI BUILDER j" DEVELOPER FIU-- 3. DIMENSIONS SHOWN AROUND THE PERIMETER OF THE STRUCTURE ARE TO THE EXTERIOR FOUNDATION CORNERS. CHECK IN 4 PROVIDE .140 MAINTAIN POSITIVE DRAINAGE AWAY FROM. ALL FOUNOATION WALLS PER TOTAL= 18.1 HSE STK BY ATE_ —pp-pjT) REOUIRCH C N HSE RESTK BY �CNIS. �0.57 MINIMUM SLOPE F'--F -OPICRETE PANS.) 1'�!15 PLOT PLAT! SHOWS PP-J;OSED MPpo*-,EmENTS OCLf. FINAL CONSTRUCTION moAY VARf. - .... . DATE— C ....... —.", r—c—, crP?A ��TTOG. -t!D S Tv 1:1 FDN Bl(_DATE—