Loading...
HomeMy WebLinkAboutLot Certifications - 01/12/2015 (3)Utilities C'+" of electric. stormwater. wastewater. water Fort Collins For Wood , PO Box 580 oR Collins, CO 80522 970.221.6700 970.22t.6619619 fax . 970.224.6003 TDD utilitiesCg2fcgov.com . fcgov.corrvutilaes CERTIFICATION OF LOT GRADING Pursuant to City Code 26 6.544 and City Land Use Code F 3.2.2 (e) Date: January 9. 2015 Permit Application No. B1402776 Address: 2427 Cooper Crest Lane CO rcit�j '/U /2orsW-k Lot: 8 Block 3 Subdivision: Kechter Crossing Planned Land Division I,(Print) Steven M. Stricklino , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): January 6. 2015 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): /The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the approved drainage plan. SEE NOTE. By: in a manner consistent with the /2 10056 Brisbane Lane, Littleton, CO 80130 (address of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the IoUsite, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written informationlexplanation of discrepancies, and other information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970) 221.6700 Rev. 1/27/12 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property Wei. TF=4946 30 c�JL I PAD=4944.87 I- J: TF=4945.50 TF=4945.00 PAD=4944.30 I PAD=4943.67 �J J 494---- - - - -�' _-4:4 . ; DRIVEOVER- - CURB do GUTTER — _ r: B3-L8 B3-L9 B3-L7 I B B B TF=4945.60 TF=4944.90 i TF=4946.70 '• I PAD=4945.1 PAD=4944.4 PAD=4946.2 i k 1Yy� nocr mzOZ r^zLO=Z a z ;�z0 ��0Z A O 2 W RN nC A fir. Enr OV�m 0 co �p ODJ� 9 pOpVNrZ OD W GQ M--i Wm p�pWp '� n r N �2 =i ?i•n� �� Os D a = NO Z z Z m r rn r (D Oo�J T (T-16 WN�z r 0• ELEVATII Surveying, Inc. 6841 SOUTH YOSEMlTE STREET fI100 CENTENNIAL, CO 80112 4- ON -1 a/U.U1 5' U.E. 9,717SQFf M =1 K43.3 NU 1 42. as rt b It K� 51 0 Z ,43.2 ��uY Tag- 9 �4 •� taro Mno 9 4 VACANT 0 Y Its #2427 TOF-4945.15 I" vs WIDE %H.1 1:1 r 7 5.0 (DRNNAOE CERDFlCATON PASSED ON 12-03-2014.) OF HOUSE # CONIC. DRIVE 448 I CAM. 2.8 �I r� 3.4 8 « n, 15' U.E. BI 8 42.4 70.00 0.5' WALK So TRQ/UWN. _A4 �Kf TOP BACK OF CURB pOW uNE COPPER CREST LANE 53 R.O.W. �QaO: BEG%- - ,11n., PRO, 0LiUOV Sl(I,aROR 97 IW Pr 0 20 40 LTiR ••75... •' �� 11 SCALE: 1'-20' PREPARED FOR: MERRAGE HOMES LOT 8, BLOCK 3. KECHTER CROSSING PLANNED LAND DIVISION, COUNTY OF LARIMER, STATE OF COLORADO; ALSO KNOWN AS:2427 COPPER CREST LANE. ELEVATION AND DRAINAGE CERTIFICATE I HEREBY CERTIFY THAT THE ELEVATION AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN, AND TO THE BEST OF MY KNOWLEDGE AND BELIEF, ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE MEASURED TO THE NEAREST 0.1 FEET. THERE IS SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND THE ELEVATION AND DRAINAGE PATTERNS MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN, DATED 05-29-14 . THE ELEVATIONS DEPICTED HEREON MAY CHANCE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE OR UPHEAVAL OF SOILS. ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WIND OR WATER OR OTHER FACTORS. DRAINAGE DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS. LANDSCAPING OR OTHER IMPROVEMENTS. THEREFORE THIS SURVEY MAY NOT ACCURATELY DEPICT THE ELEVATION AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY. 1HC: OCWWCrt R NOT O1 I NOT WYDII DICARON LN I TO OR W1O SURVEY PUT. M IHGYL SfATpIpIf pC6 NOT WWRA•R THIS PROPO(IY 10 ![ P116 FROM MR41C6 OF StWpNC OR Ap ORYNwG WAIp AWAY INOY M IOVNp,.TON.