Loading...
HomeMy WebLinkAboutLot Certifications - 06/06/2014 (8)F,City Ot ort Collins CERTIFICATION OF LOT GRADING Utilities electric • stormwater . wastewater . water 700 Wood St PO Box 580 Fort Collins. CO 80522 970.221,6700 970 221 6619 fax . 970.224 6003 TOO utilltieS(Q'.fcgoy.com . fcgovcom/unities Pursuant to City Code 2� 6-544 and City Land Use Code 6 3.2.2 (e) Date June 5. 2014 14 Permit Application No B1306468 L�t.� Address 5745 Coppervein Street Lot. 8 Block 2 Subdivision Kechter Crossing Planned Land Division 1.(Print) Steven M. Strickling . a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date). June 2. 2014 . accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey Based on this information. I certify that (check one): -. The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached) SEE NOTE fThe elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the IoUsite as constructed are functionally adequate and equivalent to the specifically approved drainage plan. and will affect stormwater drainage on and off the IoUsite in a manner consistent with the approved drainage plan. SEE NOTE 10056 Brisbane Lane. Littleton. CO 80130 (address of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written information/explanation of discrepancies. and other information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins. CO 80521 (970) 221.6700 Rev 1,27: 12 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property CIVAS engineering June 5, 2014 FORT COLLINS UTILITIES 700 Wood Street Fort Collins. Colorado 80521 Re: Lot 8, Block 2, Kechter Crossing Planned Land Division Certification of Lot Grading The elevations and drainage patterns for Lot 8, Block 2. Kechter Crossing Planned Land Division are in general conformance with the City approved Final Grading Plan for Kechter Crossing Planned Land Division, with one minor exception. The high point locations in the rear yard are approximately 8 feet from the rear property line instead of on the rear property line as shown on the Final Grading Plan. This is because the rear property line elevations are approximately 0.6 feet to 0.7 feet lower than those shown on the Final Grading Plan, due to the elevations of the concrete pan in Outlot B, constructed as part of the subdivision drainage infrastructure improvements. Since Lot 8, Block 2 is a Type A draining lot, the high point elevations were located approximately 8 feet in from the rear property line in order to provide the minimum 2% slope in the side yard swales draining to the front yard. It is our professional opinion that this exception is not significant and will still allow for stormwater drainage to be consistent with the City approved Final Grading Plan. Sincerely, CIVAS Engineering, LLC. Steve Principal 10056 Brisbane Lane • Littleton -CO •80130 tel 720-240-5882 -fax 720-223-6M2 TF=4947.91 <t I PAD=4947.41 it 7zLf Gov _ •. — �___. �. I a rl� i I B2-L7 A % I j TF=4948.65 j PAD=4948.15So `S �mp { c% R. m _ -+ B2-L8 TF=4949.19 PAD=4948.69 ,�-- Ln / o C. B2-L9 J og " A ro TF=4949.12 / B2- \ PAD=4948.62 Ln 4. \ i ` PAD=4! I I PROPERTY BOUNDARY A \ \ �\ \ Surveying Inc, 0 6841 SOUTH YOSEMITE STREET 1100 \ \\ UI'(,OT 8 CENTENNIAL. CO 80712 �..9 \ CONSTRUCT BERM ♦ \ 8 tt \ \\ \ \ 12,319 SQFI' 1 \�.� \ All 3% ]x 41LI n \ \ \ 1 1 \ \ Itx 1• 4-1 49A I tlx 1 •. w�' OPRM4L � ' Q A' fi r„ 4J 9 ,�AB. #5745 9.1 ,fix Y TOF=4949.77 V (NO DRAINAGE PATTERN ESTABLISHED YET.) OUTLINE OF PROPOSED HOUSE 0 20 40 b 7 a col �1 p ♦BU VO COVERED �' syx a`S'6 PORCH $ e `x OUTLINE wuA OF J �O\ E%ISTINC HOUSE IUSE CONC. DRIVE +59 X47.0 p6� � $. u l 15• U.E. -4 .. COPPERVEIN�, STREET Op 4Nf Cr CURB SCALE: 1-=20' PREPARED FOR: MERITAGE HOMES I DATTij7"SMRgF1'(P LOT S. BLOCK 2, KECHTER CROSSING PLANNED LAND DIVISION, COUNTY OF LARIMER. STATE OF COLORADO; ALSO KNOWN AS: 5745 COPPEWEN STREET. ELEYAIIQN AND DRAINAGE RTIFI AT I HEREBY CERTIFY THAT THE GRADING AND. DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY OF THE PROPERTY DESCRIBED HEREON. PERFORMED ON THE DATE SHOWN. AND TO THE BEST OF MY KNOWLEDGE AND BELIEF, ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE MEASURED TO THE NEAREST 0.1 FEET. THERE IS SUBSTANTIAL POSITIVE SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND THE GRADING AND DRAINAGE PATTERNS SUBSTANTIALLY MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN. DATED 12-9-13 . THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE OR UPHEAVAL OF SOILS. ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WINO OR WATER OR OTHER FACTORS. DRAINAG DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS, LANDSCAPING OR OTHER IMPROVEMENTS, THEREFORE THIS SURVEY MAY NOT ACCURATELY DEPICT THE GRADING AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY. THIS DOCUMENT IS NOT AN IMPROVEMEM LEMON CERTIFICATE OR UY10 SURVEY PUT. THE ABOVE STATEMENT DOES NOT WM T MI5 PROPERTY TO BE FREE FROM MSTANCES OF STAN01N0. OR SLD'N ORM INO WATER AYMY FR01.1 THE FOUNWTON.