HomeMy WebLinkAboutLot Certifications - 06/06/2014 (8)F,City Ot
ort Collins
CERTIFICATION OF LOT GRADING
Utilities
electric • stormwater . wastewater . water
700 Wood St
PO Box 580
Fort Collins. CO 80522
970.221,6700
970 221 6619 fax . 970.224 6003 TOO
utilltieS(Q'.fcgoy.com . fcgovcom/unities
Pursuant to City Code 2� 6-544 and City Land Use Code 6 3.2.2 (e)
Date June 5. 2014
14
Permit Application No B1306468 L�t.�
Address 5745 Coppervein Street
Lot. 8 Block 2
Subdivision Kechter Crossing Planned Land Division
1.(Print) Steven M. Strickling . a Colorado registered professional engineer, verify that the above
referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified
professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete,
and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey
performed on (Date). June 2. 2014 . accurately and truly depict the elevations and drainage patterns as
they existed on the date of the survey Based on this information. I certify that (check one):
-. The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached) SEE NOTE
fThe elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the IoUsite as constructed are functionally adequate and equivalent to the specifically approved
drainage plan. and will affect stormwater drainage on and off the IoUsite in a manner consistent with the
approved drainage plan. SEE NOTE
10056 Brisbane Lane. Littleton. CO 80130
(address of signing party)
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written
information/explanation of discrepancies. and other information necessary to confirm the above certification to:
Fort Collins Utilities
700 Wood Street
Fort Collins. CO 80521
(970) 221.6700
Rev 1,27: 12 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property
CIVAS
engineering
June 5, 2014
FORT COLLINS UTILITIES
700 Wood Street
Fort Collins. Colorado 80521
Re: Lot 8, Block 2, Kechter Crossing Planned Land Division
Certification of Lot Grading
The elevations and drainage patterns for Lot 8, Block 2. Kechter Crossing Planned Land Division
are in general conformance with the City approved Final Grading Plan for Kechter Crossing Planned
Land Division, with one minor exception. The high point locations in the rear yard are approximately
8 feet from the rear property line instead of on the rear property line as shown on the Final Grading
Plan. This is because the rear property line elevations are approximately 0.6 feet to 0.7 feet lower
than those shown on the Final Grading Plan, due to the elevations of the concrete pan in Outlot B,
constructed as part of the subdivision drainage infrastructure improvements. Since Lot 8, Block 2 is
a Type A draining lot, the high point elevations were located approximately 8 feet in from the rear
property line in order to provide the minimum 2% slope in the side yard swales draining to the front
yard. It is our professional opinion that this exception is not significant and will still allow for
stormwater drainage to be consistent with the City approved Final Grading Plan.
Sincerely,
CIVAS Engineering, LLC.
Steve
Principal
10056 Brisbane Lane • Littleton -CO •80130
tel 720-240-5882 -fax 720-223-6M2
TF=4947.91 <t I
PAD=4947.41 it
7zLf
Gov _ •. — �___. �. I
a rl�
i I B2-L7
A % I
j TF=4948.65 j
PAD=4948.15So
`S �mp
{ c% R. m _ -+
B2-L8
TF=4949.19
PAD=4948.69
,�--
Ln
/
o
C.
B2-L9 J
og " A
ro TF=4949.12 / B2-
\ PAD=4948.62
Ln
4.
\ i ` PAD=4!
I
I
PROPERTY BOUNDARY
A
\
\
�\ \ Surveying Inc,
0 6841 SOUTH YOSEMITE STREET 1100
\ \\ UI'(,OT 8 CENTENNIAL. CO 80712
�..9 \
CONSTRUCT BERM
♦ \
8 tt \ \\ \ \
12,319 SQFI' 1 \�.� \
All 3% ]x 41LI n \ \ \
1 1 \ \
Itx 1• 4-1 49A I tlx
1
•. w�' OPRM4L � ' Q
A'
fi
r„ 4J 9 ,�AB. #5745 9.1 ,fix Y TOF=4949.77
V
(NO DRAINAGE PATTERN
ESTABLISHED YET.)
OUTLINE OF
PROPOSED HOUSE
0 20 40
b
7
a
col
�1
p ♦BU
VO
COVERED
�' syx
a`S'6
PORCH
$ e
`x
OUTLINE
wuA
OF
J
�O\
E%ISTINC
HOUSE
IUSE
CONC. DRIVE +59
X47.0
p6�
�
$.
u
l
15• U.E.
-4
..
COPPERVEIN�,
STREET
Op 4Nf Cr CURB
SCALE: 1-=20' PREPARED FOR: MERITAGE HOMES I DATTij7"SMRgF1'(P
LOT S. BLOCK 2, KECHTER CROSSING PLANNED LAND DIVISION, COUNTY OF LARIMER. STATE OF COLORADO;
ALSO KNOWN AS: 5745 COPPEWEN STREET.
ELEYAIIQN AND DRAINAGE RTIFI AT
I HEREBY CERTIFY THAT THE GRADING AND. DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY
OF THE PROPERTY DESCRIBED HEREON. PERFORMED ON THE DATE SHOWN. AND TO THE BEST OF MY KNOWLEDGE AND BELIEF,
ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE
MEASURED TO THE NEAREST 0.1 FEET. THERE IS SUBSTANTIAL POSITIVE SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND
THE GRADING AND DRAINAGE PATTERNS SUBSTANTIALLY MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN. DATED
12-9-13 . THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE
OR UPHEAVAL OF SOILS. ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WINO OR WATER OR OTHER FACTORS. DRAINAG
DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS, LANDSCAPING OR OTHER IMPROVEMENTS, THEREFORE THIS
SURVEY MAY NOT ACCURATELY DEPICT THE GRADING AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY.
THIS DOCUMENT IS NOT AN IMPROVEMEM LEMON CERTIFICATE OR UY10 SURVEY PUT.
THE ABOVE STATEMENT DOES NOT WM T MI5 PROPERTY TO BE FREE FROM MSTANCES OF STAN01N0. OR SLD'N ORM INO WATER AYMY FR01.1 THE FOUNWTON.