CERTIFICATION OF LOT GRADING
Pursuant to City Code 2Q 6.544 and City Land Use Code 6 3.2.2 le
Date. November 18 2014 n1FI .
Permit Application No. B1401918 CO releorcd 'I/q�Zot4
Address: 5615 Coppervein Street
Lot: 8 Block: 1
Subdivision: Kechter Crossing Planned Land Division
(,(Print) Steven M. Strickling , a Colorado registered professional engineer, verify that the above
referenced property in the City of Fort Collins. Colorado, has been inspected by me or an appropriately qualified
professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete,
and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey
performed on (Date): October 29 2014 , accurately and truly depict the elevations and drainage patterns
as they existed on the date of the survey. Based on this information, I certify that (check one):
The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
ZThe elevations and drainage patterns of the IoUsite as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved
drainage plan, and will affect stormwater drainage on and off the lot/site in
approved drainage plan. SEE NOTE.
By:
manner consistent with the
10056 Brisbane Lane. Littleton, CO 80130
(address of signing party)
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written
informationlexplanation of discrepancies, and other information necessary to confirm the above certification to:
Fort Collins Utilities
700 Wood Street
Fort Collins, CO 80521
(9701221-6700
Rev 1,127112 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property
CIVAS
encyineering
November 18, 2014
FORT COLLINS UTILITIES
700 Wood Street
Fort Collins. Colorado 80521
Re: Lot 8, Block 1, Kechter Crossing Planned Land Division
Certification of Lot Grading
The elevations and drainage patterns for Lot 8, Block 1, Kechter Crossing Planned Land Division
are in general conformance with the City approved Final Grading Plan for Kechter Crossing Planned
Land Division, with a few exceptions. The side yard swale high point locations are approximately 35
feet further toward the rear yard are approximately 1.0 foot lower than those shown on the Final
Grading Plan. This was necessary in order to provide adequate drainage, as per code, from the
finish grade on the side of the structure toward the side yard swales. The result of these exceptions
is that approximately 850 s.f. of the side yards will drain toward the Coppervein Street instead of
toward the concrete pan in Outlot A. However, it is our professional opinion that these exceptions
are not significant and will still allow for stormwater drainage to generally be consistent with the City
approved Final Grading Plan.
Sincerely,
CIVAS Engirleering, LLC.
Steven M.`SirickGng, P.E.
Principal
10056 Snsbane Lane • uttleton -CO .80130
iv 720-240-5882 fax 720-223-6092
Al
Al
B1-L6
TF=49946.61
PAD=4946.11
r _
:B1-ppL7
TF=4946.70
i PAD=4946.10
I
i
B1-L8
i
B
I I rn TF=4946.96
PAD= 4946.45
L.... � t
7 � m 00 it -,=.
> .�
m 1
o i
I
� Z I
M>l
�D.D
no I zo
<FD200
�Z�U)22
xm�
z
x
C2
rl Z
B1-L9
B !
I
TF=4946.96 i
PAD=4946.46 i
i y I B1-L10 j
B
I D 4946.3 P8
! DRIVEOVEI
C� 3 CURB doqUTTER
B1-L11 i
I
B
ATION AN
CATE
6841 SOUTH YOSEMITE STREET JIOO
CENTENNIAL, CO 80112
ER6TIR
R
u.0
TIMBERLINE ROAD
OU,nOT A 8IX dR B
9.04.] 5' U.E
s{94W
u05
-
. C5
I1
A� 7S205QF'41
v
�,
�.o
9
1z
K
R45.2 x45.1
C 6
Sf1 1
gT 45.W
N
a5.2
x45.1
I
=
,
{S.O1x
11
Ei
46.1
$�
N zoxl
460
nx 44.3
46.0
aix
9
4.7
E s,x
.5
(NO DRAINAGE PATTERN
YET)
I
0
EXI
OUTUNE OF
EXISTING HOUSE
q
"`
#5615
439I
TOF-4946.88
4
COVRIY.wO
-
� •T
.WALK
Bx
!Ph'
H. —�
1451
CONE. DRIVE'
xM.l I
n
00'a...
1B'34 E -
4
.JB• \5 U.E. B.M. 4.5'
56 i0.EE/U`WN �
COPPERVEIN STREET
SY R.O.W.
FA
VTLINE OF
STING HOUSE
(DRAINAGE CERTIFICARON
PASSED ON 09-30-201{)
WNA
1BACK OF CURB
—FLOW UNE
i� PRO 0 d S(f�ES.'OR
0 20 40 9.T},}`#A.-
SCALE. 1'-20' PREPARED FOR: MERITAGE HOMES
LOT S. BLOCK 1, KECHTER CROSSING PLANNED LAND DIVISION, COUNT! Of LARIMER, STATE OF COLORADO;
ALSO KNOWN AS:5615 COPPERVON STREET.
ELEVATION AND DRAINAr.E CERTJnCATE
I HEREBY CERTIFY THAT THE ELEVATION AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY
OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN, AND TO THE BEST OF MY KNOWLEDGE AND BELIEF.
ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE
MEASURED TO THE NEAREST 0.1 FEET. THERE IS SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND
THE ELEVATION AND DRAINAGE PATTERNS MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN. DATED
04-11—ta THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE
OR UPHEAVAL OF SOILS. ADDRION OR REMOVAL OF SOILS, EROSION OF SOILS BY WIND OR WATER OR OTHER FACTORS. DRA)NAGI
DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS, LANDSCAPING OR OTHER IMPROVEMENTS. THEREFORE THIS
SURVEY MAY NOT ACCURATELY DEPICT THE ELEVATION AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY.
THIS OOCUMMT a NOI AN rnxwsmn L TON CERMCATE OR LAND Svffi Y PUT.
THE AlKNE 9TAm BDa NOT wARRurt TNB PR9RBPM1 m BE'RaX `ROW W4h w STn HC OR s TIRWNNC WAWR mr FROM TIC RPUNDARDN.