HomeMy WebLinkAboutLot Certifications - 09/16/2015Utilities
CI}"
electric stormwater. wastewater. water
Of
Fort
700WoOn
PO Box 580
Collins
Fort Collins., CO 80522
970.221.6700
970.221.6619619 fax . 970.224.6003 TDD
utilities(a)fCgoy,cOm . logov,com/utilifies
CERTIFICATION OF LOT GRADING
Pursuant to City Code 26 6-544 and City Land Use Code 4 3.2.2 (e
Date: September 16, 2015 Awl
Permit Application No. BP1501250
CO fltaoStC 'A-1 S
Address: 2426 Copper Crest lane
Lot: 7 Block: 12
Subdivision: Kechter Crossing Planned Land Division
(,(Print) Steven M. Stricklino , a Colorado registered professional engineer, verify that the above referenced
property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under
my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the
elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed
on (Date): Auaust 19, 2015 , accurately and truly depict the elevations and drainage patterns as they existed
on the date of the survey. Based on this information, I certify that (check one):
❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
xThe elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved
drainage plan, and will affect stormwater drainage on and off the lot/site in a manner consistent with the
approved drainage plan. SEE NOTE. bk
By:
31237'
O�sS/ONAt �G �
(signature, PE stamp)
For and On Behalf of
CIVAS Engineering, LLC
10056 Brisbane Lane, Littleton, CO 80130
(address of signing party)
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, Including but not limited to drawings of the lot/site showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written
Information/explanation of discrepancies, and other Information necessary to confirm the above certification to:
Fort Collins Utilities
700 Wood Street
Fort Collins, CO 80521
(970)221-6700
Rev. V27/12 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property
civas
engineering
civil engine nng solutions
September 16, 2015
FORT COLLINS UTILITIES
700 Wood Street
Fort Collins, Colorado 80521
Re: Lot 7, Block 12, Kechter Crossing Planned Land Division
Certification of Lot Grading
The lot grading for Lot 7, Block 12, Kechter Crossing Planned Land Division is in general
conformance with the City approved Final Grading Plan for Kechter Crossing Planned Land
Division.
An earth drainage swale is indicated in Common Area A, Kechter Crossing Planned Land
Division, as shown on the Final Grading Plan — 30 Scale (sheet 21 of 55), in order to convey runoff
from the rear yards of Lots 5, 6, 7 and 8, Block 12, Kechter Crossing Planned Land Division and
the side yard and portions of the rear yard of Lot 1, Block 12, Kechter Crossing Planned Land
Division and Lots 1 and 8, Block 11, Kechter Crossing Planned Land Division to a public storm
sewer system in Crossview Drive. At the time the Grading Certification for Lot 7, Block 12, was
prepared, it appears that the earth drainage swale on the north side of Lots 7 and 8, Block 12 (the
south side of Lot 1, Block 11) was not constructed properly and drainage is not being adequately
conveyed to the west to the earthen drainage swale that was constructed properly. We have
spoken with Meritage Homes about this issue and understand that they are working with the
developer of Kechter Crossing to get this issue resolved.
It is our professional opinion tha
Sincerely,
CIVAS Engineering, LLC.
JUJ/'
0
�0
'9
70NAL;av Gx
Steven M. Strickling, P.E.
t
10056 Brisbane Lane • Littleton • Colorado • 80130
tel 720-240-5882 0 lax 720-223-6092 0 w .civas-eng.conn
N 1
O� i I rna !
rnoi DRAINAGE
_
v u f SWALE
0
4a m
I ~a
DRAINAGE SWALE
FL 41.1` 5 (ASSUMED
•I NO ELEVATIONS OR GRADES
ARE SHOWN FOR THE
DRAINAGE SWALE. BASED ON
THE CONTOURS, IT IS
— — ASSUMED THAT IT IS r
INTENDED TO SLOPE AT 1 % �I
I
DRAINAGE SWALE
FL 40.40 (ASSUMED) �++J
DRAINAGE % , 4
00
J
m
I�
�I
OM
I
m
m
Il p
~a
sf
tph�
SWAB LE
DRAINAGE SWALE
FL 40.00
5' SOFT PATH SEE
ETAIL SHT 47 TYP
/ V.a- 4\'
—
I
� Mo I
J (o.
�m I
N aQ
m �a I
■ ni
m1
C - 1 2261
8I1-L1
14,
F 1 Bn-LJ
9 Y A Y �Y
dAo i 7� y�B
i`
1 • � 1 I� 1
911-LI I i
I
tx
I _ +
ij
9
-A li 1
FI: LS 9, -L6 BI^-LJ
r l T I 3 B B
1 I
I
1 •4' 9wv 1 ��3'F
COPPER CREST LANE
IT
83 LB
} u + BJ L5 B]-La BJ-U B e -
il+Fi I
a04
t pp yy pp p �tFP6AAF�1�F37i; 33Af£gAt" F
�� � 6 Y I � N A � � �' � —__ � ��a�$➢§$E�„$�OFCgFf� @��I� ' - -
A its
y 5 11 p S-¢E
1
3 i VIA L
u $ IS /(ECMTER CROSSING
3 3iii IN��
Q FINAL GRADING p�
q y I S j PLAN-30 SCALE! y�j
i C `L 9]9LIQCBR�LLC. LANLRA CpAPY, CO ;;,,9 Fi }
AND
IIR
6841 SOUTH YOSEMITE STREET #100
CENTENNIAL, CO 80172
COMMON AREA
da.a a 5' raaL
C 0 9
70O rt 5
�
dtJ
5 UE
5' 3 atA .E-I 4 w
Is
7
N
W
N
in %r%8'1$QT(' 0
^
435x p
x43.2 .431 x411 42.9x
1
c
C
Z
y
�i •� „r
r 44 5 e4 6 44 6
xa2.5
42 i 441 SIW�' I eke
1
6
OUTLINE OF
EXISTING HOUSE
(DRAINAGE CERTIFICATION
PASSED ON 02-20-15 .)
IIH
8
OUTLINE
3 i EXISTING HOUSE
2.9
'^
0 (NO ORaNALE PATTERN
1ST; #2426 16x "1 ESTABLISHED YCT)
TOF=4945.36
Iox $ Ks�'• CC12R&p ux
o PORC�i a ~
f
60 ,�_5 4undJ.Jx 20
ip .1 + 42.4
u ... 70.00'.I'
y, a. $ WALK
5.6' TREE/LAWN
TOP BACK OF CURB
LOW LINE
COPPER CREST LANE -_ .,
53' R.O.W.
0 20 40
SCALE. t"�20' PREPARED FOR. MERITAGE HOMES DA II
LOT 7, BLOCK 12, KECHTER CROSSING PLANNED LAND DIVISION, COUNTY OF UIRIMER, STATE OF COLORADO,
ALSO KNOWN AS'2426 COPPER CREST LANE
ELEVATION AND DRAINAGF CERTIFICATE
HEREBY CERTIFY THAT THE ELEVATIONS AND DRAINAGE PATTERNS SHOWN WERE DEVELOPED FROM AN SURVEY PERFORMED UNDER
NY DIRECT SUPERVISION ON THE DATE SHOWN TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE GRADING FOR THE LOT SHOWN
aEREON WAS MEASURED TO THE NEAREST TENTH OF A FOOT AND ACCURATELY REFLECTS THE DESIGN OF THE APPROVED AREA
GRADING PLAN PREPARED BY THE ENGINEER OF RECORD, ELEVATIONS AND PATTERNS MAY CHANGE SUBSEQUENT TO THIS AS A
RESULT OF NATURAL AND/OR MAN-MADE OCCURRENCES.
THIS DOCUMENT IS NOT AN IMPROVEMENT LOCATION CERTIFICATE OR LAND SURVEY PLAT.