Loading...
HomeMy WebLinkAboutLot Certifications - 10/07/2014 (16)Utilities City of electric. stormwater. wastewater. water Fort Collins For Wood St PO Box 580 Fort Collins. CO 80522 970.221.6700 970.221.6619 fax . 970.224,6003 TDD utilitieslo3fcoov.com . fcgov.comyumiees CERTIFICATION OF LOT GRADING Pursuant to City Code 2s 6-W and City Land Use Code 6 3.2.2 (e) Date. October 6, 2014 Permit Application No B1401751 f`FI Address: 5609 Coopervein Street CO (Amszd 'O/i/ZDI ba� Lot: 7 Block: 1 Subdivision: Kechter Crossing Planned Land Division 1,(Print) Steven M. Strickling , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): September 30, 2014 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. Q The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a manner consistent with the approved drainage plan. SEE NOTE. By: (s 10056 Brisbane Lane, Littleton, CO 80130 (address of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written infonnation/explanation of discrepancies, and other information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO $0521 (970) 221-6700 Rev 1127112 At !east Two Weeks Prior To Requesting A Certification Of Occupancy For The Property CIVAS engineering October 6, 2014 FORT COLLINS UTILITIES 700 Wood Street Fort Collins. Colorado 80521 Re: Lot 7, Block 1, Kechter Crossing Planned Land Division Certification of Lot Grading The elevations and drainage patterns for Lot 7, Block 1, Kechter Crossing Planned Land Division are in general conformance with the City approved Final Grading Plan for Kechter Crossing Planned Land Division, with a few exceptions. The side yard swale high point locations are further toward the rear yard are approximately 1.0 foot lower than those shown on the Final Grading Plan. This was necessary in order to provide adequate drainage, as per code, from the finish grade on the side of the structure toward the side yard swales. The result of these exceptions is that approximately 650 s.f. of the side yard of Lot 7, Blockl will drain toward the Coppervein Street instead of toward the concrete pan in Outlot A. However, it is our professional opinion that these exceptions are not significant and will still allow for stormwater drainage to generally be consistent with the City approved Final Grading Plan. Sincerely, CIVAS Engineers LLC. Steven M StriL0-64. P.E. Principal 10056 BriSbane Lane • �ttteton - CO •80130 tel 720-240-5882 -fax 720-223-6092 Al :.1 c 0 Al �- B1-L6 \` = \ TF=4946.61 PAD=4946.11 X. Lo jTF=4946.70 L PAD= 4946.10 + B1-L8 \ T •� 1 { 0) TF=4946.96 PAD=4946.45 O �mDrn B1-L9 -a=v z B o c z o i TF=4946.96 i t 10 Z m PAD=4945.46 I O V) I � 10 O FnzmA� l B1-L10 rn i v TF=4947.10 (n PAD=4946.38 �I DRIVEOVER r2 ? CURB & M i CL _ C� - _ rn I I " B1-L11 I' Surveying, Inc. 6841 SOUTH YOSEMRE STREET 1100 CENTENNIAL, CO 80112 E� 45.iR �f 8 OUTLINE OF EXISTING HORSE (NO DRAINAGE PATTERN ESTABLISHED YET.) TIMBERLINE ROAD OUTLOT A -+ it 34 4' CONCRETE RAN- N43.67 96. 9 ^^' 44.1 W.7 N44.6 N14.6 fi h h gj gl g� 8,6B2 SQFT ' 4 7 1 41,1 i6R n N.F. mw • 52 ".YM]}3' MiN ++•J fi #5609 pT, TOF=4946.45 'j6 COV'D PORCH GONG.. DRIVE' �e 7' ni +J? f I •� *JB Wl .• \ WAtK IT U.E. fi +1+ a.a. 1.5' 5.6' COPPERVEIN STREET 53' R.O.W. Dw INC cuft \ -- 6 'ROPOSED HOUSE (NO ORNHAGE PATTERN ESTABLISHED YET.) PROD 0 ! SL%I�tE40R 0 20 40 SCALE. 1"-20' PREPARED FOR: MERRAGE HOMES DA. ' LOT 7, BLOCK 1, KECHTER CROSSING PLANNED LAND DIVISION. COUNTY OF LARIMER. STATE OF COLORADO; ALSO KNOWN AS:5609 COPPERVEIN STREET. ELEVATION AND DRAINAGE CERTIFICATE I HEREBY CERTIFY THAT THE ELEVATION AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN, AND TO THE BEST OF MY KNOWLEDGE AND BELIEF. ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE MEASURED TO THE NEAREST 0.1 FEET. THERE IS SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND THE ELEVATION AND DRAINAGE PATTERNS MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN, DATED 02-25-14 . THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE OR UPHEAVAL OF SOILS, ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WINO OR WATER OR OTHER FACTORS. DRAINAGI DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALXS. LANDSCAPING OR OTHER IMPROVEMENTS, THEREFORE THIS SURVEY MAY NOT ACCURATELY DEPICT THE ELEVATION AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY. THIS OCCU T 6 NOT AN NPRp4MEeR LOCARUN cmml w OR IAND Sump PuT 1WC A D SYAIDICR DD[5 NOY WARRANT TN6 PROPQHY T° BE IRCE FROM INSTANCES V STANdNG OR $ W NWG WAWR AWAY FROM T12 1WNDATDN.