Loading...
HomeMy WebLinkAboutLot Certifications - 03/03/2015Utilities City Of electric. stormwater. wastewater. water 7 700 Wood St. Fort Collins Fo Box 580 Fort Collins, CO 60522 970.221.6700 \` 970,221.6619619 fax . 970.224.6003 TDD utilities(Qfcgov.Com . icgov.com1utirnes CERTIFICATION OF LOT GRADING Pursuant to City Code 25 6-544 and City Land Use Code 6 3.2.2 (e) Date: March 3. 2015 Permit Application No. B1403836 tJFI. Address, 5603 C000ervein Street CO rd<, .d '/shot Lot: 6 Block: 1 Subdivision: Kechter Crossing Planned Land Division (,(Print) Steven M. Strickling . a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): February 20 2015 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the Iot/site'are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. /he elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a manner consistent with the approved drainage plan. SEE NOTE. By: 10056 Brisbane Lane. Littleton, CO 80130 (address of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the IoUsite. Including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written informationlexplanation of discrepancies, and other Information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80621 (970)221-6700 Rev. 1127112 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property ` CIVAS engineering March 3, 2015 FORT COLLINS UTILITIES 700 Wood Street Fort Collins, Colorado 80521 Re: Lot 6, Block 1, Kechter Crossing Planned Land Division Certification of Lot Grading The elevations and drainage patterns for Lot 6, Block 1, Kechter Crossing Planned Land Division are in general conformance with the City approved Final Grading Plan for Kechter Crossing Planned Land Division, with a few exceptions. The southerly side yard swale high point location is further toward the rear yard are approximately 1.0 foot lower than that shown on the Final Grading Plan. This was necessary in order to provide adequate drainage, as per code, from the finish grade on the side of the structure toward the side yard swales. The northerly side yard swale high point elevation is approximately 65 feet further toward the rear property line, but is within 0.2 feet of the high point elevation shown on the Final Grading Plan. However, it is our professional opinion that the high point location of the northerly side yard swale as shown on the Final Grading Plan is incorrect because the resulting grade of the swale sloping toward the rear yard is only 1.25%. The high point location should be approximately 45 feet toward the rear yard in order to provide the minimum required slope of 2%. The result of these exceptions is that approximately 520 s.f. of the southerly side yard of Lot 6, Block 1 and approximately 350 s.f. of the northerly side yard of Lot 6, Block1 will drain toward the Coppervein Street instead of toward the concrete pan or drainage swale in Outlot A. However, it is our professional opinion that these exceptions are not significant and will still allow for stormwater drainage to generally be consistent with the City approved Final Grading Plan. Sincerely, CIV Ste 10056 Brisbane Lane • Littleton . Colorado • 80130 tel 720-240-5882 0 fax 720-223-6092 • www cNas-eng corn Al T 0 r O ' ` \ PROPERTY BOUNDARY _ VERTICAL CURB do GU co z- - - - WN ol -9Arb 1—L5 L B Al B1-L6 i B TF= 4946.61 PAD=4946.11 B1-L7 B TF=49463( PAD=4946.1 B1-L8 B 0: TF=4946.96 r PAD=4946.45 TF= 4945.80 PAD=4945.30 ATION YOSEMITE STREET 1100 Q GO 60112 OQ. ,4 A 05, 4° 9 OUTLINE OF EXISTING HOUSE (DRAINAGE CERTIFICATION PASSED ON 09-50-3014.) IZ119 QFC x45.1 45.1x x45.0 6f SNKS' S' 45k.1 'x R� I's x 45.0 RA #5603 TOF=4946.75 (' GONG. DRIVE P{ xq.8 �E 2.8 29 , ' k 15 U E. -4 CCtt2 4. +fit D fa` .,OUTLINE OF EXISTING HOUSE (NO DRAINAGE PATTERN ESTABLISHED YET) v 1 � _ TOP BAOK OF CURB / PRO O SIiOR 0 20 ao SCALE: 1".20' PREPARED FOR: MERMAGE HOMES DATFi 11 LOT 6, BLOCK 1, KECHTER CROSSING PLANNED LAND DIVISION, COUNTY OF LARIMER, STATE OF COLORADO; ALSO KNOWN AS: 5603 COPPERVEIN STREET. ELEVATION AND DRAINAGE RTIFI .AT THE GRADING FOR THE LOT SHOWN HEREON ACCURATELY REFLECTS THE DESIGN OF THE COUNTY OF LARIMER APPROVED AREA GRADING PLAN PREPARED BY THE ENGINEER OF RECORD. I HEREBY CERTIFY THAT THE ELEVA71ON AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN, AND TO THE BEST OF MY KNOWLEDGE AND BELIEF, ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE MEASURED TO THE NEAREST 0.1 FEET. THERE IS SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND THE ELEVATION AND DRAINAGE PATTERNS MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN, DATED 07-07-14 . THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE OR UPHEAVAL OF SOILS, ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WIND OR WATER OR OTHER FACTORS. DRAINAGE DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS, LANDSCAPING OR OTHER IMPROVEMENTS, THEREFORE THIS SURVEY MAY NOT ACCURATELY DEPICT THE ELEVATION AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY. THIS ODCUIIFNT 6 NOT AN MPROrEYQR UO IION Q FKATE OR IAND SGRYEY PIAT. W A STATiOAQR W[5 NOT WARRANT THIS PROPON TO N ITQ IRON MSTAN= OF STANUNG OR ADW ORNN&G MA NMAY INOY YNE TOUNbnON.