HomeMy WebLinkAboutSite Certifications - 04/07/2004NCLTE BEYOND ENGINEERING April 7, 2004 FC0025902 Jay Barber Stormwater Engineer City of Fort Collins - Stormwater Utility 700 Wood Street P.O. Box 580 Fort Collins, Colorado 80521 SUBJECT: Drainage Certification for Larimer County Corrections Center Dear Jay: Delta Construction, Inc. has finished constructing the drainage improvements at the Larimer County Corrections Center (LCCC). This Drainage Certification Letter and the attached exhibits present a summary of the record survey data and the results of my review of the record survey data. Nolte Associates, Inc. collected record survey data at the LCCC on 03/11/04 and 03/17/04. I have reviewed the record survey data and visited the project site. During this site visit, I confirmed that the drainage improvements were completed in compliance with the approved construction plans. The attached construction plans (i.e., sheets DRO1 and DR02) were updated to include the drainage improvement record survey information. The on -site detention pond consists of three (3) component volumes that, when added together, comprise the 100-year detention storage volume. Table 1 (see below) lists the approved design volume and record survey volume of each component detention pond. Table 1. On -Site Detention Pond Detention Pond(per Volume Approved Design)(per Volume Record Survey) ft ac-ft ft ac-ft Upper Detention Pond i.e., Basin 102 2,408 0.056 1,942 0.045 Lower Detention Pond (i.e., Basin 103) 10,613 0.246 11,213 0.257 Parking Lot Detention Pond (i.e., Basin 100) 5,079 0.117 4,200 0.096 Total: 18,100 0.418 17,355 0.398 ' NOLTE ASSOCIATES, INC. C_ seal -twtFA S 1901 SHARP POINT DRIVE, SUITE Ar� �Qe FORT COLLINS, CO 80525 �� ,//p �Sy(j e.S �r ✓ 970.221.2400 TEL 970.221.2415 FAX ��GC�Y.i.��",/• �- / WWW.NOLTE.COM I �.ufAY.C//`�sC st- S'�l"/`O Jay Barber April 7, 2004 Page 2 The as -constructed detention pond provides approximately 96% of the detention storage volume of the approved design detention storage volume. Also of importance is the Water Quality Capture Volume (WQCV). The as -constructed detention pond provides the WQCV (i.e., 0.51 ac-ft) of the approved design at elevation 5006.18. Therefore, the total detention storage volume and the WQCV of the as -constructed detention pond are in substantial conformance with the approved design. Other on -site drainage improvements were checked against the approved plans. These improvements include the Water Quality Outlet Structure, Culvert `A', and Culvert `B'. Refer to sheets DRO1 and DR02 for the respective record survey information. Each of the improvements was found to be in substantial conformance with the approved plans. If you have questions about the information presented in this letter, please contact me at (970) 419 1340. Sincerely, Nolte Associates, Inc. o�pp0.REG�s� �FBE •• F9 33066 Herman Feissner, P.E. �; y°y 107 lan.;�� Associate Engineer ��F'•• ,,,,.�' �� SS10nin1 N O L T E ASSOCIATES, INC. N:\FCO259\Drainage\Word\Drainage_Certification_Barber_20040407.dw �Av-ai1a61eXoltitt Calk lat►on � � r 11 ihl- E On SiteDetentionPbndn',yE `�''#�, Tly "RECORD SURVEYINF.ORMA•TTONAn �" Project #: FCO259 Project Name: Larimer County Community Corrections Facility Calculated By: HHF Date: 4/7/2004 Detention pond volume (V): 1/3d(A+B+(AB)05) (uniform sides) Where: V= Volume between contours, ft' d= Depth between contours, ft A= Surface area of contour line, ft' B= Surface area of contour line at a depth relevant to d, fe BEYOND ENGINEERING Upper DetentionPond (Basin 101 Volume Elevation feet Dd ft A fe B fe Volume ft3 Cummulative Volume ft3 Cummulative Volume ac-ft Vo 5005.72 0.00 0 0 0 0 0.000 V 1 5006.00 0.28 0 191 18 18 0.000 VWpcv 5006.18 140 0.003 VZ 5007.00 1.00 191 1,385 696 696 0.016 V100WSEL 5007.65 0.65 1,385 2,503 1,246 1,942 0.045 _ Lower Detention Pond (Basin=1.03 ` _ - Volume Elevation feet Dd ft A fe B fe Volume ft3 Cummulative Volume ft3 Cummulative Volume ac-ft Vo 5005.34 0.00 0 0 0 0 0.000 V, 5006.00 0.66 0 4,481 986 986 0.023 VWpcv 5006.18 1,986 0.046 VZ 5007.00 1.00 4,481 6,707 5,557 6,543 0.150 VIOOWSEL 5007.65 0.65 6,707 7,675 4,671 11,213 0.257 Parking Lot Detention Pond Basin 100) - Volume Elevation feet Dd ft A f? B ftZ Volume ft3 Cummulative Volume fit Cummulative Volume ac-ft Vo 5006.12 0.00 0 0 0 0 0.000 VWQCv 5006.18 120 0.003 V, 5007.00 0.88 0 2,004 588 588 0.013 VIOOWSEL 5007.65 0.65 2,004 10,156 3,612 4,200 0.096 WQCV: Estimated 100-year W.S.E.L.: Elevation feet Cummulative Volume ac-ft 5005.34 0.000 5006.00 0.023 5006.18 0.052 5007.00 0.180 5007.65 0.398 Nolte Associates, Inc. 41712004 8:16 AM MAY-24=2004 MON 01:59 PM NOLTE ASSOCIATES NOLTE ASSOCIATES, INC. 1901 SHARP POINT DRIVE, SUITE A FORT COL4fNS, CO 80S39 97D.221.2400 TEL 970.221.2415 PAX WWW.NOLTC.COM TO FAX NO. 9702212415 P, 01 NOLTE a TON MCI INC Gi11 NG FAX TRANSMITTAL Name: m eh)uete� Company: Fort Collins Stormwater Utility Fax #: (970) 221.6619 Date: 5/2412004 CC: NOTES Glen, Please read the attached memorandum. FROM Name: Herman Feissner Office: Fort Collins Tel. #: (970) 419-1340 Job #; FC0025902 Total # pages including cover. 2 Original will not be mailed. If you have questions or comments, please contact me at (970) 419-1340, Sincerely, ian�'Feissner, P.E. Associate Engineer NAFCO259\Dra1na2.6WomArAX Schlueter 20040524.doc 5/24/2004 MAY-24=2004 MON 01:59 PM NOLTE ASSOCIATES FAX NO, 9702212415 P..02 May 24, 2004 FcoOSvm_ Glen D. Schlueter Stormwater Dcvelopment Manager City of Fort Collins - Stormwater Utility 700 Wood street P.O. Box 580 Fort Collins, Colorado 80521 SUBJECT: Drainage Certification for Larimer County Corrections Center Dear Glen: The following was prepared in response to our telephone conversation on May 24, 2004, The as -constructed detention pond, at the Larimer County Corrections Center, provides 96% ol'the design storage volume. The shortfall of approximately 745 W, between the design storage volume and the as-e mshucted storage volume, is made up if the 100-year water surface elevation rises approximately 0.05' (i.e., from 5007.65 to 5007.70). As the water surface elevation rises to 5007.70, the water will just begin to spill into the adjacent Midpoint Drive public R.O.W. Tho available firoeboard will be compromised by approximately 0.05'. The estimated rise in water surface elevation will not have an adverse impact on the neighboring Properties, the adjacent Midpoint Drive R.O.W., or the parking area that the on -site detention backs up into. If you have questions about the information presented in this letter, please contact me directly at (970) 419-1340. Sincerely, Nolte Associates, Inc. Berman Feissner, P.R. Associate Bnginocr n:\fe0259\drainage\word\n,emoscliluctcr20040524.doc MAY-17-2004 MON 10:19 AM NOLTE ASSOCIATES FAX N0, 9702212415 NOLTE ASSOCIATES, INC. 1901 SHAkP POINT DRIVE, SUITE A FORT COLLINS. CO 80$25 970.221.2400 TEL 970,221,2415 FAX WWW,NOLTE.COM TO NOLTE B 6 Y O N D G N O I N E C R I N D FAX TRANSMITTAL Name: Glen Schlueter Company: Fort Collins Stormwater Utility Fax #: (970) 221-6619 Date: 5/17/2004 CC: G NOTES S Glen, Please read the attached memorandum. FROM Name: Herman Felssner Office: Fort Collins Tel. #: (970) 419.1340 Job #: FC0025902 Total # pages including cover: 3 Original will not be mailed. 1f you have gLlestions or comments, please contact me at (970) 419-1340. Sincerely, v' Herman Fcissner, P.B. I I NAFCO259Tminago\Word\FAX Schlueter 20040S 17.doe 5/17/2004 MAY-17-2004 MON 10:19 AM NOLTE ASSOCIATES FAX NO, 9702212415 P. ,02 May 17, 2004 rcoo:sm Glen D. Schlueter Stormwater Development Manager City of l'ort Collins - Stormwater Utility 700 Wood Street P.O. Box 580 Fort Collins, Colorado 80521 SUBJECT: Drainage Certification for Larimer County Corrections Center Dear Glen: 1 read your comments about the on -site detention pond at the Larimer County Corrections Center (i.e., LCCC). You are correct that two of the areas were short on volume while the third provided some extra volume. However, a loss of volume in one area can be made up in another area because these three areas are one detention pond. The on -sits detention pond consists of three component volumes that, when added together, comprise the 100-year detention storage volume for the entire project site. These areas do not operate as independent detention ponds. During a stone event, the excess runoff in basins 100 and 102 will drain into basin 103, As the water surface in basin 103 rises, it will spill into the adjacent basins (i.e., basins 100 and 103). 1f extra volume is available in basin 103, below the design high water line, it will be filled. The component areas are hydraulically connected and designed to function as one detention pond. If C.Xilvert 'A' and Culvert 'B' were not in place, there would only be one pond on the project site. However, these culverts were necessary. Without the culverts, the sidewalks could not have been constructed. In conclusion, lost storage volume in one area can be made up in another area. If you have questions about the information presented in this letter, please contact me directly at (970) 419-1340. n:\fc0259\dr3inage\word\memoschlueter20p40517,doc MAY-17=2004 MON 10:19 AM NOLTE ASSOCIATES FAX NO. 9702212415 K .03 Jay Barber April 7, 2004 Page 2 Sincerely, Nolte Associates, Inc, Herman Feissner, P.E. Associate Engineer I 0 N.VCO2S9Zmio¢µ\WCrd\MunaSCh]wlW2i)040S 17..Wc DEVELOPED DRAINAGE SUMMARY CHART 4908--- pxpx 1 eB� 1 1 1 1 1 1 102 11 0.35 Or it 1 Oy II 1 I I I 11 1 1 ' 1 i 1 I Ii I , 1 1 1 si 400 0.11 0. 5 0.31 i in P / 1 6F 1 I 'I 11 li I I I I I ' I � I I I I I I I I lii I II SF I I II 1 I I I I � 1 11 11 II I II Y I I II I I 11 1 II I I II I I u I 1 I 1 1 IIi i I 100 1.66 0.' PROPOSED CORRECTIONS CENTER F.F.-5010.00 �l0m 2 0 0 i U ? Q / l 1.1 aan[ 906 2' WOE CONCRETE PAN W/6- MIDPOINT DRIVE _ _ `--� VFATCAL _ - _ xrv. mT 2, W19 Is CHASE SPI W Y OULVERT C - 24'x5O' PEH1ClE a STT V�j.-0J6 16.20 LF n TRACKING CONTROL in 301 L PAD FOR DETA1EE SET %%% 102 11 I t2 - 10 WaS E SHEET _ DRO2-FOR DETAIL ER - m wN y CDOT IN T vlc -I - I - p -mx a R ryE .C. Ir 103 I - 1 0.29 0.33 I \ l I `}.. 300 0.40\ 0.06 D0l70.>s f a I ,, 0.05 S• ' mint 1 /I `\ ' tE ffi PROPOSED 70 D R' 101 '$'DETENDoel 0.2J I o.as 10, I ti 40 f I I I I I I I i \1 n . 100-year WSE5 a �Iq YAI11 1 CUT D.P. BASIN(S) AREA (m) cfs) 0r lift) 100 100 1.66 3.64 10.76 101 101 0.27 1.26 270 102 102 0.36 D.36 0.95 103 102 o.Xl 0.36 1.00 200 200 0.00 0.35 0.64 300 300 0.05 MI 0.51 301 3D1 iDS 0.30 0.)) X2 302 O.D9 0.15 0.39 400 40D 0.12 S14 0.16 OS-1 OS-1 I aw 1.21 3.21 LEGEND X BASIN DESGNATION BASH AREA '% %v 10-yr. 'CCf' COEFFICIENT 100-W. 'CCf' COEFFICIENT Iiiiiiiii BASIN BOUNDARY 301 DESIGN POINT ---------- EXISTING V CONTOUR ------- --- EXISTING 5' CONTOUR -sr:.- PROPOSED V CONTOUR -Slb- PROPOSED 5' CONTOUR PROPOSED STORM DRAIN PIPE ® VEHICLE TRACKING CONTROL OPROPOSED SILT FENCE 05.49 RECORD SURVEY ELEVATION DETENnON POND 100-yeor HWL:4907.65 Emergency Spillway Elew6on:4907.65 Require0 VNume:0.41 -ft Available Vall0..11-oc Fk 0.40 ac-ft Allowable Relabee:0J2 Its (i.e., 2-year Historic Rate) CULVERT P 20.23 L.F. CULVERT 2: 19.54 L.F. OILVERT 3: 16.79 L.F. O A n Q w ~ J a Imo: m I J 0 J CC CC a U z Q O IL U Z u) O Z °' _O Cr U z LLI a FY q pF D Z U a o FIGURE 1= m Iasi City of Fort Collins, Colorado II= PLAN APPROVAL . APPROVED: O'vecbr of bp0eaioR Date CHECKED BY: vela 6 veebeeter Duty Dele CHECKED BY: 1 Slormeeler DaDy Os[e adl xuwem DR01 CHECKED BY: Pvb a ba Wu Oete OF i S0.0E CHECKED BY: t Irce - m It. Deb IFFIKAI. rim./a rgTiwLIL r'm A' CHECKED BY: OA a F FCO26B pirate Pe,rwntian Di •� a,. Threat either :,.... I M oll Anneen An lithene 1. ifive donoth Intel", "Neel or . dent I AnNotheyhoodereener MAN e At Anne I Ile 4 �� -... pripere An or Floor Anic felt cor, &A the nor In or the Fee no New n 2 Irepror enter In In For Ar Arructions . An, be into 'I An Intent, Ill tee. Not or Me rinly - lento Andhher . .1 Ann, r..,.., IF 11 w here.. then.. .¢teem 1. All .,,IA, I in,"' lien e whole 0 to. i .. loneenry, on ery to Ile he .., too he ae, a tee. >, the tIC—.m „e: l "Anner 1. few All dry-Anothera .�.mn Aree ere,ws : n. Ir a, mmnww mn. Anne m.e,c dinner Con ,...i n... e.m. ..clawt wn—. e..., cr �.. Al s, or III the nsi"p inner wwm no 0060. 1 me u1. GenteCme,oll Any 'Foley yon w m•n ale^: se-o,.evimCIA Mgt [Iline it her approne ere n.0 w Feel mm ue to...It mnem or m unn " u. it) E.ampb Pplaatlon PoLLeme Men lot Ali or renulotered nore It.. IN Air hot "I, enoi. e.que 1. no ,e teem . mu npuu. 1. A, in weeen boyer "AFFAMentype tellan . G . M,e e Clean �..4 0. D.w Mine .min,,. Go,.e Lee.." as An Anner .A thater Net Tor ..ter...._._...__. m,.., r _..I,.. ,nother Ne 1. All We No onlyi C All m� r �,l `� S I. mIprroohr SerOn a -A earee Tol or Devil .�.� Ate to hi Wine t DN _.. v,...h P9 read door A II lot In looll I,ra�Il Alto reogrell—le —re,oulen.l. or ...., An. ,Yon, . or ALnA Co.A Satin B-B - Mon Nee SecOm C-C on II .. en,...-...�...,..mnnn- min..... '.... R No 1++Ali m)AP ..x. 1") 1. HB.. e_e m,m n.,.e, r ", a. , %� e,.e , ,� anew, pal ,.i. "..a C 3) u.n w o .cote o-.i. ee,w (uA �}Oeeu EMERGENCY SPILLWAY ELEVATDN-490g.65 ME It 100- . W.SELAA 4907.65 liiAS Tin -OFFICE BATE. TYPE 'C INIFT BOX 0 MOCV W.S.E.L.A1906.1] { (SEE OETAL THIS SHEET) f TRASH RAM a 0,� 6o ADS N-12 n t WTFAL PIPE o INV. INa INV. QUT� 190SI1 WATER QUALITY 19p5.39 ORU CE PLATE QUTSDE FRONT MEW (N.T.S) 100-pin WFSrl 1907b5 0 RAZE0gESH M' WVCV WSEL. 49M17 Ally Tell n FlM91E0 irl BADE NOTES: L AREA PER RONAl On. CIRCULAR PERFORATION DIA -0.49- - USE (J) COUMNS - UK (2) R0W5 2. USE MOT TYPE 'CINLET W/CLOSE MESH IRATE 1. FOR TRASH RACK DETAIL REFER TO R9ve 6 IF Figure 6-0 1. Office Mote eMmete - 4 5/16" (i.n. LXI M) WATER QUALITY OUTLET STRUCTURE DETENTION POND — BASIN 101 N.T.S. III M n, �me[I�� INLET ON GRADE (FLOW' IFw ME ainvewI INLET CONNECTED TO AT CROSS CULVERT w �"' NM,N aae,/Y re N�i>MW,Na I 1 � 1 INLET CONNECTED TO A xmPM A - A SKEWED CROSS CULVERT INLET AT BOTTOM �q NA%I UY b� I At Q O $LT FpN£ W SLT FENCEINSTALLATNNI � I w[u u�inxal iwe� ro�,�i Feel Warner ll wl �FLOW `INV Me n ` l SECTION At 41 a DETAIL SILT FENCE EROSION BARRIER __ u"Ar EmureC 13Bmm Ormar an.M Mew be) ell T Me I toy. A Tpl— WIN one ka T u Wri' `G OIL W . rl lI w I T .,N WALL WtWM MOT Al MAN � pun DETAL4. y f* GRATE INSTALLATION DETAIL xarE.RNwReL�Ow,Es rim-w-Luau yW�m�WrT .mmmww W. .we i,[V.TOM 9O4 YN OwL a'' CONCRETE INLET imeOm°rteeii C'nor tiP .,/,' o Fin. a,a CIA xcrwN o—M YA Conerythe e� R e T- line 1 aKm AT 2 w NTeL i xcnal LreTn.r sill L 1 i i� .w DIII ...ovate CONSTRUCTION SEQUENCE PROJECT: AaWNC] CaeW COmmmYh. COMOIwu STANDARD POBM C SEQUENCE FOR POUT-= COMPLETED BY: HNP or 0]/8B/800.9 INDICATE BY USE OF A BAR LINE OR SYMBOLS WHEN EROSION CONTROL MEASURES WILL BE INSTALLED. MAJOR MODIFICA➢ONS TO AN APPROVED SCHEDULE MAY REWIRE SLUMMING A NEW SCHEDULE FOR APPROVAL BY THE CITY ENGINEER. Cello at as a Alone 11 he 3 been 17 My a Art III m I Ili All m a ember For W MOST Fa or Mae„ I. or WORTH All OK.. JA.V. TM YIR AMR.u• min MOv OVERLOT GRADING WIND EROSION CONTROL SOL ROUGHING PERIMETER BARNEF ADDIDM1 BARRIERS VEGETATIVE METHODS SOIL SEALANT OTHER RAINFALL EROSION CONTROL STRUCTURAL: SEDIMENT TRAP/BASIN INET FILTERS STRAW BARRIERS SLT FENCE BARRIERS SAND BAGS BARE SOL PREPARATION CONTOUR FURROWS TERRACING ASPHALT/ CONCRETE PAVING OTHER VEGETADVE: PERMANENT SEED PLANING MULCHING/ SEALANT TEMPORARY SEED PLANTING SOD INSTALLATION NETTNGS/ MATS/ BLANKETS OTHER c U z a Q LL U Z y Q J z Q City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: Diregkr 9t B•,Tiuevio` DWk CHECKED BY: Welu a rMk,.Ia UUDy DWk CHECKED BY: RkimW.ki uwq n.k CHECKED BY: 6T DR02 PvtE d ReaeEUoe Dek 11 R All Inncu: ,Ianrcwac r=n/n CHECKED BY: Date CHECKED BY: DWk xR rvu9aR FCO25@