Loading...
HomeMy WebLinkAboutLot Certifications - 12/18/20144 City of Utilities electric.. stormwater. wastewater. water Fort Collins 700 Wood St. PO Boz 580 Fort Collins, CO 80522 970.221.6619 970.221.6619 fax : 970.224:6003 TDD ufilities@fcgov.com . icgov.com/ufilxes CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-5U and City Land Use Code § 3.2.2 (e) Date: co If e'r'-Sea 7/ % -'/� 2/I$�Ztcl� �/bAk Permit Application No. 1B1301 oo $ �313obOc} —a Address:( Lot: Block: (-f r+-le a.SaJ Il/iy./Zol4- Subdivision: L.00;ltS 42R S �HYTGowlt3 CAZIZiAQ1 - 14005E {Ir a..-i;ra let: la I,(Pdnt)4-tff/✓ i 13 _ a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and d inage attems shown on the attached drawings) which were developed from a survey performed on (Date): L L accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the IoUsite are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the IoUsite in a map aer.consisten with the approved drainage plan. SEE NOTE. aE.1 ,tF1 Y. _ B (sig PE stamp) c b21���e� u 9. a° (address of signing partyykkj R NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificateof;Occupai for the loVslte, including but not limited to drawings of the IoUsite showing the approved design and as-bulli suiveyeecc elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written informationlexplanation of discrepancies, and other information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970) 221-6700 Rev. 1127112 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property �'owr�.S1o�T �f I�1�. COfJ�tl 4, 42c� 40 A'trec} 1` Ao AV-e S4TX,4 Is "AS-BUIL T" CRADINC 429 S WHI TCOMB ST., FT. COLLINS.. COLO. XS#4715 5004.5 FT NGVD 29 12�:=� SCALE 1" = 30' 100 YEAR HIGH RISK (f) FLOOD FRINGE BOUNDARY— y NGVD 29 5004 BFE BENCH MARK CITY OF FORT COLLINS BM #1-11 NGVD29 ELEVATION Q 5005.44 LOCATED AT THE SOUTHEAST CORNER OF MULBERRY STREET AND LOOMIS AVENUE, AT THE NORTHEAST CORNER OF A CONCRETE TRAFFIC SIGNAL BASE SHIFT ALL ELEVATIONS +3.18• TO MATCH INTO NAVDBB VERTICAL DATUM THIS PROPERTY IS LOCATED WITHIN THE CITY OLD TOWN FLOOD PLAIN 5 FT Prepared By. Forbes Engineering 3 1 �--------- E-- ss 20' ALLEY wry _ gry 34 sr3 5 �� g \ e, „�" ` 100 YEAR y soa6ea MODERATE RISK _ I BOUNDARY FLOOD GE a+ a+. :F � I �o^ 0lO 1 I � I I 1 I s GARAGE AMMON 1 5 h� 6.21 Nye g� �96 " ( 100 YEAR �I� MODERATE RISK & W FLOOD FRINGE R BOUNDARY I +�96 4.19 I I �gof I 100 YEAR 33j — HIGH RISK FLOOD FRINGE 0000000, BOUNDARY XS 4358 I —> 5002.8 FT S. WHI TCOMB A VENUE NGVD 29 S ` I Sheldon House B&B 616 W Mulberry St - I �ry �s J �ti 20' ALLEY 1 100 YEAR FLOOD _t PLAIN BOUNDARY PROPOSM CAMAGE FF-W s5o 0 r i i I yti� I� jr cp I i BENCH MARK ¢ O A moo CITYMFFOR UNS ARK BEN5005.44 5004 B FE / ok6 ELEVATION _ PROPOSM GM,GE LOCATED AT THE SOUTHEAST CORNER OF \/ AMMON MULBERRY STREET AND LOOMIS AVENUE, AT THE NORTHEAST CORNEOF A RSIGNAL CONCRETE TRAFFICR C I I r h BASE I ' 11 I { I 421 . South �,. Whitcomb ' o l ;��� ° 100 :YEAR FLOOD I _j` PLAIN BOUNDARY ff t e 3 — PROPOSED GRADING SCALE I • - 30' S. WHl TCOMB A VENUE . FORBES ENGINEERING CUL:M.• coNOR FLAmGAN Y PREPARED B KEVIIV FOReEs 2908 CHERLY STREET, Ft. Collins, Colorado 80524 PROJECT' 429 S WHTCOMB ST DRAWN. DATE Tel,. (970) 295-4874 fT.COL1lN$ CO KEF 2-25-13 sync a> 0. aW7M A AV DESM SHEET �RU- FDf77017MN_% LAfM : KNOPA PLAMW ME PROPOSED GRADING do DRAIA14GE PLAN PROJECT � 13-1720 DWG if 1720—PR Dan Mogen From: Kevin Forbes <kevinforbes@frii.com> Sent: Tuesday, December 16, 2014 9:52 AM To: Dan Mogen Subject: RE: Grading Cert Attachments: 429 Whitcomb Grading Certification.pdf Dan, Here's the grading cert with the proposed grading plan and the appropriate box checked. The only exemption being the finish floor of the garage being built below the proposed elevation. Thanks, Kevin Forbes Engineering LLC 2908 Cherly St., Ft. Collins, CO Office (970) 295-4874 Cell (970) 232-6014 kevinforbes@frii.com From: Dan Mogen [mailtoAmogen(Mcgov.coml Sent: Monday, December 15, 2014 12:49 PM To: 'Kevin Forbes' Subject: RE: Grading Cert Kevin, Attached is the grading plan that you put together for this. Dan Mogen, El, CFM Stormwater Engineer City of Fort Collins Utilities (970)224-6192 dmosen@fcaov.com From: Kevin Forbes [mailto:kevinforbes(Wrii.coml Sent: Monday, December 15, 2014 10:21 AM To: Dan Mogen Subject: RE: Grading Cert Dan, Here's the grading cert for Conor Flanagan. Let me know if you need anything else. Kevin Forbes Engineering LLC 2908 Cherly St., Ft. Collins, CO Office (970) 295-4874 Cell (970) 232-6014 kevinforbes@frii.com From: Dan Mogen [mailto:dmooen@fcgov.coml Sent: Friday, December 12, 2014 2:57 PM To: 'kevinforbes@frii.com' Subject: Grading Cert Dan Mogen, El, CFM Stormwater Engineer City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80522 (970)224-6192 dmosen@fcsov.com Fort Collins UtOitEes