Loading...
HomeMy WebLinkAboutLot Certifications - 08/13/1999 (2)AUG 11 93 WED 11:43 AM POUNDATION_ENGINEEPING FOUNDATION II Engineering, AND SOILS Inc. FAX NO. 13706631660 -T'7RPMArr,TER �Owl lit AUG 111999 9 Au"ust9, 1999 Commission No. 1036-07-07.0) 0 �( Griess Construction 225 Park Place Court Port Collins. Colorado 80525 P. 4 RR: Overlot Grading for Lot 91. Huntington Hills, 6" Filing (543 Saturn Drive) H'nrr Colorado Gentlemen: We have measured the relative elevations at the ahove referenced address During the investigation we measured elevations at the lot sides and corners, top of foundation, lowest opeving, and the drainage swalcs on the subject lot. Our representative noted that the swales on the west and cast sides of the subject lot allowed Rot?,7 flow to reach the sidewalk to Qic ttutth dud the Swale slung the south draining to the east. The r usidence to the west of the subject lot (Lot 92) was complete and guadcd, the residence to the S(a i; (Lot 86) was complete with landscaping and fencing, and the residence to the cast (Lut 90) was under k,onstruction at the time of our investigation. Based on our observations. and the inlurutatiu;t available to this office, the slopes and elevations as measured are in substantial conformance vti itl: thc. PI lA grading plaueomplctcd by JR L•ngincering. Ltd., JobNo. 9018.13. dated hebruary 5, 1 .0 7 Furthermore, it is our opinion that the subject lot, as graded, should not interfere with offsitc tucw;. nor cause runoff to flow into another residence unless the grades are changed or barriers are crcauni' such as fences, garden terracing, sidewalks and/or any landscaping which may change the establish-- flow patterns by diverting or slowing runoff flow. Backlill adjacent to the residence may settle o. ct time and allow pending to occur around the foundation walls. The backfill adjacent to the residence must be monitored and maintained by the homeowner to ensure that runoff will flow away from the foundatiou. If you have any questions, please feel free to call. R�i}�cctful��� —� • _ �..Vti rd P. Ilain S. Environmental/ .arth Sciences Specialist CPH 1_,.,,,ed bti A. Cherry, P.E. 1.1-UNJI.A) ON Ar. S'(III.\ 1-:N(ilNF.lF:.RING, INC I IU Granite Street. Suite D -Loveland. Colorado 80538-(970;)663-0138 •Fax (970) 663-1660 .�00 Kimbark Street, Suite 101 -Longmont, Colorado 80501 9(303) 702-0661 *Fax (303) 774-841 AUG 11 93 WED 11 44 AM IOUNDATION_I11GIN[IP]PdG PAx N0, 13706631660 P. AS -BUILT GRADE ELEVATIONS 543 54TURN DRIVE BENCHMARK NUJ P/C (B.O.W.) 56.5 •:-� b• a _ 59. — 58.4 0 .CI lyl OI - zl ELEVATION$ SL;RVET'ED 8.9.59 f-- NE F/C MACK OF WALK) 6 58.9 TOP OF FOUNUA I IUN • 61.3 LOWEST OPENING 00.6 59.1 59Z • 59.3 59.Y 58A 58.6 rov.2 58.3 51.3 NOTEt THIS GRADING PLAN 16 BASED UPON THE BEEF R:+0sk1ATION AVAILABLE TO THIS OFFIfF. AT THF. TIME OF FA.IRVFT' 36- -T•5 P CIUN AT I O N coVruL rIl�lCs GLEN 6RI .55 2 Wr L'.: EVIVE5 LOT LTH SCALE ImIN6FAIvLFORT COLLINS, COLORADO •70 STRUCTURAL FOUNDATION AND SOILS ENGINEERING ---"- — CJT LOVELAND C.MORADO W-VIA AUG 11 39 WED 11 44 AM FOUNDATION_ ENGINEERING Pnx NO. 19706631660 P, 6tL 3 1! •_•►_._...mow- � w• ___ �..! .� a = 6�3 90 92 91 �O I �84. • 57.8 85 I 86 I 87 roF•�o. I I ; ITM44Lr AUTOMATIC COVER SHEET PATE : AUG-11-99 WED 11:45 AM TO : STORM WATER FAX # : 2216619 FROM : FOUNDATION -ENGINEERING. FAX # : 19706631660 7 PAGES WERE SENT (INCLUDING THIS COVER PAGE)