Loading...
HomeMy WebLinkAboutLot Certifications - 12/15/2000 (4)FROM : Scott, Cox & Assoc. All December 6, 2000 FAX NO. : 970 663 1660 Dec. 14 2000 09:14RM P1 SCOTT, COX & ASSOC:IATES, INC:. 1 onsuh ing engineers S7�' (iriess Construction 325 Park Place Court Forl Collins, Colorado 80525 Project No. 1036-07-14-06 Gentlemen: A4�n 1 DEC 14 20 IS'W ( We have measured the relative elevations for the over lot grading at Lot ?5 Huntington_Hills_6'"_Filing_(538 Hwltin;;ton-Hips_Dt7ve).Fort Collins, Colorado. During the investiontinn, we measured elevations at the lot sides and e(irn'ers. top of foundation. lowest openinb, and the drainage swales on the cast and west sides of the subject lot. Our eepfesentative noted that the swale on the cast side ofthc subject lot allowed runoff flow to reach the sidewalk, south critic subject lot, and the open space north of the subject lot at the time of our observations. The observed elevationsforthe northeastand northwest property comers were approximately Zero to one and one -tenth feet(U-1.l') higher than indicated on the Area Grading, Drainage and Erosion Control Plan for this subdivision. The observed elevation for the top of foundation was approximately three -tenths of a foot (0..V) higher than indicated. The residence to the east of the subject lot (Lot 24) was complete and landscaped, the open space to the west and north of the subject lot appeared to he graded and was covered with weeds at the time of our observations, Based oil our observations, and the information available to this office, the slopes and elevations as measured, with the above noted exceptions, are in general conformance with the intent of the Area. Grading Drainage and Erosion Control Plan completed by J.R. Engineering, Ltd., Job Number 9018.13, dated February 5, 1997, Please refer to the attached copies ofthe As -Built (,trading Elevations and Ana Grading, Drainage and Erosion Control Plan for further information. Furthermore, it is our opinion that the subject lot, as graded, should not interfere with offsite flows unless the grades arc changed or barriers are created such as fences, garden terracing, sidewalks and/or any landscaping which may change the established flow Patterns bydivertingorslowingrunoff flow. Backfill adjacent to the residence may settle over time and allow ponding to occur around the foundation walls. The baekftll adjacent to the residence must be monitored and maintained by the homeowner to ensure that rintolT will flow away from the foundation. I'hank you lbr consulting with us on this phase of the project. If you have any questions, please feel free to call. Sincerely SCOT-T, COX & ASSOCIATES Reviewed by: C'To P. Lnvimnmcntal Specialist (i:\('ioin(itttling Ccn�\GRIfC$�1034-7-13.3.��pd PP ved by - James James A. Cherry, P.E, ,n In r onlfe St(CCL Suite U • I wx•Mirwd , CAdnrmlo nfRtn • !wi)j uhi-t,ll iy - ",ix: (970I W.Mfi(I Sm1n� Wo:adn fvhh nf1*wN io • soNWl" • - I ffV,•I:N(I FROM : Scott, Cox & Assoc. FAX NO. : 970 663 1660 Dec. 14 2000 09:15AM P2 m mI0 rL �m D 21 <m s m < T. mmD W �N �p N 7�p N �N � m z= LO Nm A r d , e3 e N m a pan 9E a � e � � • • s C� '• r I11 L r f9 O • pI. L n � f° • 0 y N d I m 0 Ohm A o E E 2 n� =o j � U% ti ' • O S � I� Q 'f � 1W,, 1 W LTZ W N W J W w J -N N .� 0 E0 W ® W r n m CC D .. 49 r 'Aw ��I kA N.